根据实验过程的数学模型,分析了电感耦合等离子体质谱法测定酱油中铅和总砷含量的不确定度来源,对不确定度分量进行计算,并计算出合成不确定度及扩展不确定度。  相似文献   

3.
建立一种电感耦合等离子体质谱法同时测定药用辅料山梨醇中铅和镍含量的方法。试样采用稀硝酸溶解,在线加入元素钪和铋为内标,同时测定溶液中铅和镍的浓度,以外标法定量。结果表明,铅和镍的质量浓度在0~50μg/L的范围内均与离子强度具有良好的线性关系,相关系数大于0.999,检出限分别为0.004,0.009 mg/kg,重复性试验的相对标准偏差低于5%,加标回收率介于90%~110%之间。该法操作简便,快速,灵敏,准确度高,适用性好。  相似文献   

4.
采用HNO_3-H_2O_2微波消解样品,电感耦合等离子体质谱法(ICP-MS)同时测定化妆品中的汞、铅、砷、锑.实验中探讨了最佳的消解程序,选择适当的同位素,并用铋、铟、锗做内标元素,有效地抑制了分析信号的漂移.结果表明,各元素的检出限在0.089~0.37μg/kg,相对标准偏差(RSD)在0.709%~2.10%,回收率为80.10%~102.67%.该方法具有简便、快速、准确、灵敏度高的优点,适用于化妆品中的汞、铅、砷、锑元素的同时测定.  相似文献   

5.
建立微波消解–电感耦合等离子体质谱法测定酱卤肉中铬、砷、镉、铊、铅5种元素含量的检测方法。采用微波消解法处理酱卤肉样品,对预处理条件和仪器工作参数进行了优化,以内标校正法降低基体影响。结果表明,铬、砷、镉、铊、铅5种元素的质量浓度在0.1~50.0 μg/L范围内与质谱响应值具有良好的线性关系,相关系数均大于0.999,方法检出限为0.2~6.2 μg/kg。在3种加标浓度水平下平均回收率为72.4%~113.5%,测定结果的相对标准偏差为3.1%~7.7%(n=6)。该方法简便,快速,高效,准确,可为酱卤肉中铬、砷、镉、铊、铅的测定提供技术支持。  相似文献   

6.
采用微波消解法处理海洋贝类样品,用电感耦合等离子体质谱法测定样品中镉、铬、铜和铅等4种重金属元素的含量。选择111 Cd、53 Cr、63 Cu和208 Pb等待测元素的同位素克服了质谱干扰。4种元素分别在一定的质量浓度范围内呈线性,检出限(3s)在0.005~0.17μg.L-1之间。镉、铬、铜和铅的回收率分别为94.7%,102.1%,101.9%,105.3%;测定值的相对标准偏差(n=7)分别为4.3%,3.8%,1.5%,6.0%。  相似文献   

7.
采用电感耦合等离子体质谱法(ICP-MS)测定食用植物油中铅(Pb)、总砷(As)含量,对测定结果的不确定度进行评定。利用ICP-MS,采用标准加入法测定食用植物油中Pb,As含量,分析测定过程中不确定度来源,包括样品称量、定容、前处理、溶液中Pb和As浓度、重复性测量等引入的不确定度,计算合成不确定度。结果表明,Pb含量为(0.0228±0.013) mg/kg,k=2;As含量为(0.00785±0.0045) mg/kg,k=2。该方法的不确定度主要来源于样品溶液中的Pb,As浓度,评定得到的不确定度可为正确评价测定结果提供科学依据。  相似文献   

8.
采用硝酸-双氧水-氢氟酸体系对苎麻不同部位样品进行微波消解,通过智能控温加热器赶酸,利用电感耦合等离子体质谱(ICP-MS)检测苎麻不同部位的铬、砷、镉及铅含量.结果表明:方法操作简便,分析速度快,灵敏度及线性较好,各元素的检出限为~(52)Cr 0.05 mg/kg、~(75)As 0.02 mg/kg、~(111)Cd 0.02 mg/kg、~(208)Pb 0.03 mg/kg,线性范围分别为Cr 0.5~50 mg/kg、As和Cd均为0.1~12.5 mg/kg、Pb 0.2~25 mg/kg.方法精密度和稳定性较好,试验回收率在80.0%~125%之间.初步判断苎麻不同部位4种重金属元素的高低水平,以及苎麻对土壤中的重金属有一定吸附作用.  相似文献   

9.
建立草酸沉淀分离氧化钕,用校正方程消除残余钕离子产生的双电荷离子干扰,电感耦合等离子体质谱法测定砷含量的方法。选择了溶解样品条件,硝酸溶解样品即能满足检测要求;优化了仪器条件,功率1500W,雾化器流量0.86L/min;进行了内标元素的选择,确定Rh为最佳校正内标元素;确定用草酸分离基体并结合干扰校正方程消除钕的双电荷离子干扰;方法检出限为0.029 ng/mL,定量限为0.097 ng/mL。采用方法对实际样品进行测定,回收率(n=11)为94%~104%,相对标准偏差(RSD,n=11)为0.56%~5.82%。  相似文献   

10.
采用电感耦合等离子体原子发射光谱测定了当归、黄芪及两种药材不同配伍形式的水煎液中铅、铬、镉、砷等金属元素含量。比较了不同提取方法及磷脂类化合物对当归补血汤中这些金属元素溶出的影响。实验表明,当归、黄芪生药材及水煎液经硝酸消化,样品消解完全,能满足电感耦合等离子体-原子发射光谱(ICP-AES)检测的要求。方法加标回收率为83.0%~96.0%,相对标准偏差为0.36%~4.67%,且当归∶黄芪配比为1∶5时水煎液中重金属元素溶出率低于1∶1配比,证实了当归补血汤经典配方的合理性,为其临床疗效提供了有效依据。  相似文献   

11.
采用电感耦合等离子体质谱(ICP-MS)与等离子体光谱(ICP-OES)联机同时测定多金属结核样品中常量、微量、痕量元素。样品经高压密封溶样弹消解后,一次气动雾化进样,ICP-OES测定常量和微量元素,ICP-MS测定微量和痕量元素。详细探讨了不同浓度范围元素的测定方式、元素分析信号的采集模式、多原子离子干扰的校正因子。采用ICP-MS与ICP-OES二种方式同时测定Co、Cu、Ni、Zn、V、Ba、Sr,分析结果表明具有较好的一致性。所建立的ICP-MS与ICP-OES联机检测技术用于多金属结核标准样品的分析(Nod-A-1,GSPN-1,GSPN-2,GSPN-3),分析结果与推荐值符合,相对标准偏差小于10%。  相似文献   

12.
Accurate determination of lithium (Li)isotopic composition in natural geological samples is the basis for Li isotope geochemical studies. In this study, a method contained preparation of geological materials (water and rock) and accurate determination of Li isotopic composition was set up. The separation of Li from water and rock samples was implemented by a single column containing 1.5 mL of Bio-Rad AG 50W-X12 (200–400 mesh) resin, with 0.40 M HCl and 1.0 M HCl as eluents. Only 8.5 and 14 mL of eluents were used to separate Li from water and rock samples with this method, respectively. Blank signal of the operation procedure was (2.4 ± 0.1) mV, which was almost same as the 2.3 mV of the 2% HNO3 signal used in this study. Experimental results showed that Li isotopic fractionation during leaching process was significant and deviation of δ7Li values in these samples with incompletely recovered Li reached up to 50‰. Lithium isotopic ratios were determined by multi-collector ICP-MS (Nu Plasma II) using the sample standard bracketing (SSB) method. L-SVEC standard with similar Li concentration to samples (about 80 ng mL?1) was used in this study. The external precision (2σ) of this technique, determined by repeated measurement of pure Li standard solutions and seawater was < ±0.8‰. The measured δ7Li values of seawater and rock standards AGV-2, BCR-2 and GSP-2 were +31.4‰ ± 0.7‰ (n = 18), +7.23‰ ± 0.16‰ (n = 4), +3.7‰ ± 0.7‰ (n = 8) and ?0.10‰ ± 0.18‰ (n = 4), respectively, similar to previously published values. This method could be used to accurately determine Li isotopic composition of various types of geological samples such as waters and rocks. The advantage of this method was that the amount of resin and reagent was reduced to 50% or less of the previous studies, thereby significantly improving the work efficiency and reducing the operation procedure blank.  相似文献   

13.
建立了电感耦合等离子体质谱法(ICP-MS)同时测定矿泉水中痕量溴、碘,比较了不同酸碱度对溴、碘测定的影响。测量过程中对溴、碘的记忆效应进行消除,选择了最佳的工作条件,溴、碘的方法检出限分别为0.63,0.112μg/L,相对标准偏差分别为3.1%和1.8%,加标回收率为96%~107%。对国家标准水样进行了测定,测定结果与推荐值一致性较好。  相似文献   

14.
电感耦合等离子体质谱法测定土壤中痕量铀   总被引:1,自引:0,他引:1  
建立电感耦合等离子体质谱法测定土壤样品中痕量铀含量的方法。采用硝酸、氢氟酸、高氯酸混合酸消解样品后,以铼为内标溶液校正基体干扰,用电感耦合等离子体质谱仪测定土壤中的痕量铀含量。实验结果表明,铀的质量浓度在0~20 ng/m L范围内与信号强度呈线性关系,相关系数r=0.999 9,方法检出限为0.006μg/g,测定结果的相对标准偏差小于5%(n=6),加标回收率在96%~103%之间。用该方法与标准方法对同一样品进行测定,两种方法测定结果一致。该方法准确可靠,满足土壤样品中痕量铀含量的测定要求。  相似文献   

15.
煤作为有机物与无机物的复杂混合物,含有多种微量元素,不同的微量元素信息代表不同的地质意义,稀土元素可以提供丰富的沉积环境与物源信息。采用高压消解罐,选用硝酸和氢氟酸混合酸消解样品,建立了电感耦合等离子体质谱法测定16种稀土元素的方法。讨论了样品量、消解试剂、质谱干扰等影响因素,各元素的方法检出限在0.001~0.016μg/g,NIST SRD 1632d煤标准样品实测值和标准值一致,标准样品测定结果与实测样品结果相对标准偏差(RSD,n=11)小于5%,可满足煤中稀土元素的准确测定,为煤类样品中稀土元素测定提供了新的参考方法。  相似文献   

16.
电感耦合等离子体质谱(ICP-MS)法测定钒银矿中硒   总被引:1,自引:0,他引:1  
提出了电感耦合等离子体质谱(ICP-MS)法测定钒银矿中硒的含量。样品经逆王水加高氯酸溶解,并采用内标法消除了可能存在的质谱干扰。实验结果表明,方法检出限为0.066ng/mL,加标回收率为94%~104%,测定值的相对标准偏差(n=7)均小于5.0%。方法简单、快速、准确,适用于钒银矿中硒含量的测定。  相似文献   

17.
建立电感耦合等离子体发射质谱法测定钨矿石中钨华的含量。用氨水溶液对矿石样品进行浸取分离,将浸取液稀释10倍体积后测定,以3%盐酸溶液作为测定介质。WO3的质量浓度在0~100 ng/m L范围内与信号强度呈良好的线性关系,相关系数为0.999 9,方法检出限为0.5 ng/m L。用该方法对5个钨矿石样品和2个标准物质样品中的钨华进行测定,测定结果的相对标准偏差为2.15%~9.46%(n=12),且与经典方法极谱法测定结果的相对偏差小于10%。该方法快速、简便,精确度较高,可用于钨矿石中钨华的测定。  相似文献   

18.
同位素稀释电感耦合等离子体质谱法测量鱼样中的总汞   总被引:1,自引:0,他引:1  
发展了一种条件温和的提取鱼样中总汞的前处理方法,并建立了同位素稀释电感耦合等离子体质谱(ID-ICP-MS)分析鱼样中总汞的方法。对ID-ICP-MS测量过程中的主要误差来源进行了讨论,使用铅同位素标准参考物NIST SRM 981对测量汞同位素过程中的死时间和质量歧视效应进行了校正。对两种标准参考物(金枪鱼肉IAEA436和角鲨鱼肝NRCC DOLT-3)中的总汞用ID-ICP-MS进行了测定。IAEA436和DOLT-3总汞的测定结果分别为4.23±0.06mg/kg和3.33±0.05mg/kg,与标准值相符。此外,建立的前处理方法可以有效地降低测量过程中汞在系统中产生的“记忆效应”,有利于ID-ICP-MS的应用。  相似文献   

19.
电感耦合等离子体质谱法测定人血浆中20种微量元素   总被引:2,自引:0,他引:2  
宋娟娥  梁月琴  于水 《分析化学》2007,35(3):423-426
建立了人血浆样品中微量元素的ICP-MS测定方法。分析了100名健康成人和50名健康儿童血浆样品的20种微量元素,给出了参考值范围。该方法检出限为0.0001~1.60μg/L;精密度(RSD)介于0.78%~4.27%;多数元素回收率在100%±10%之内。方法简便(正常人血浆经超纯水,硝酸,TritonX-100,正丁醇稀释后直接测定其中的微量元素),快速,样品用量少(血浆0.2mL),可作为人体内多种微量元素的监测方法,同时为人血浆中微量元素正常值范围的确定提供了参考依据。  相似文献   

20.
样品用盐酸-硝酸-氢氟酸-高氯酸密闭分解,加入硫酸至冒烟,冷却后制备成硝酸介质溶液,使用电感耦合等离子体质谱(ICP-MS)法测定La,Ce,Pr,Nd,Sm;用过氧化钠熔融分解,水提取沉淀分离,沉淀用硝酸溶解,使用ICP-MS法测定Y,Eu,Gd,Tb,Dy,Ho,Er,Tm,Yb,Lu。根据岩石标准物质的分析结果评价方法的准确度和精密度。方法检出限(6σ)为0.002~0.021μg/g,相对标准偏差(n=12)为1.2%~9.6%,方法可用于批量岩石中稀土元素的测定。  相似文献   