首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ion-exclusion chromatography–cation-exchange chromatography was developed for the simultaneous separation of common inorganic anions and cations (Cl, NO3 and SO42−; Na+, NH4+, K+, Mg2+ and Ca2+) on a weakly acidic cation-exchange column by elution with weak acid. Generally, the resolution among these monovalent cations was only moderate, thereby hindering the determination of these analytes in natural-water samples. Therefore, 18-crown-6 was added to the eluent to improve the resolution. A good separation of these anions and cations on a weakly acidic cation-exchange column was achieved in 30 min by elution with 5 mM tartaric acid/6 mM 18-crown-6/methanol–water (7.5:92.5). The ion-exclusion chromatography–cation-exchange chromatography method developed here was successfully applied to the separation of major anions and cations in an environmental water sample.  相似文献   

2.
The application of laboratory-made zirconium-modified silica gels (Zr-silicas) as cation-exchange stationary phases to ion chromatography with conductimetric detection (IC–CD) for common mono- and divalent cations (Li+, Na+, NH4+, K+, Mg2+ and Ca2+) was carried out. Zr-silicas were prepared by the reaction of the silanol group on the surface of silica gel with zirconium tetrabutoxide (Zr(OCH2CH2CH2CH3)4) in ethanol. Zr-silica adsorbed on 10 mg zirconium g−1 silica gel was a suitable cation-exchange stationary phase in IC–CD for the separation of these mono- and divalent cations. Excellent simultaneous separation and highly sensitive detection for these cations were achieved in 10 min by IC–CD using a Zr-silica column (150×4.6 mm I.D.) and 10 mM tartaric acid containing 10 mM 15-crown-5 (1,4,7,10,13-pentaoxacyclopentadecane) as the eluent. The proposed IC–CD method was successfully applied to the determination of major mono- and divalent cations in natural water samples.  相似文献   

3.
A new method for the simultaneous determination of anions (sulfate, nitrate, and chloride) and cations (sodium, ammonium, potassium, magnesium, and calcium) in acid rain waters was investigated using high-performance ion-exclusion/cation-exchange chromatography with conductimetric detection on a separation column packed with a polymethacrylate-based weakly acidic cation-exchange resin in the hydrogen-form and an eluent comprising 1.5 mM sulfosalicylic acid–6 mM 18-crown-6 at pH 2.6, operated at 1.5 ml/min. Effective separation and highly sensitive conductimetric detection for the anions and the cations was achieved in about 14 min. Since the ionic balance (equivalents of anions/equivalents of cations) of acid rain waters of different pH (4.40–4.67) ranged from 0.97 to 0.94, evaluation of the water quality of acid rain was possible. This method was successfully applied to the simultaneous determination of the anions and the cations in acid rain transported from mainland China and North Korea to central Japan monitored by a meteorological satellite data analyzer.  相似文献   

4.
This paper describes an electrostatic ion chromatographic system in which the separation selectivity for inorganic anions, especially for sulfate and phosphate, could be manipulated by altering the molar ratio of the zwitterionic and cationic surfactants in the column coating solution used to prepare the stationary phase. The zwitterionic surfactant used for this study was 3-(N,N-dimethyltetradecylammonio)propanesulfonate (Zwittergent-3-14) and the cationic surfactant was tetradecyltrimethylammonium (TTA). Using a reversed-phase C18 column (250×4.6 mm I.D.) coated with 10/10 (mM/mM) of TTA/Zwittergent-3-14 mixed micelles as the stationary phase and either NaHCO3 or Na2CO3 aqueous solution as the eluent, together with suppressed conductivity detection, baseline separation of seven model inorganic anions was obtained. The elution order for those anions was found to be F42−42−23. Under the same conditions but using 1/10 (mM/mM) of TTA/Zwittergent-3-14 mixed micelles as the column coating solution, the elution order for these model ions was F42−42−23. The early elution of phosphate and sulfate is a unique attribute of this system. Detection limits for F, HPO42−, Cl, SO42−, NO2, Br and NO3 (S/N=3, sample injection volume 100 μl) were 0.11, 0.12, 0.12, 0.18, 0.49, 0.49, 0.52 μM, respectively.  相似文献   

5.
A new application of capillary electrophoresis for measuring major and trace anions in thermal water and condensed-steam samples is presented. Ten fluid samples were collected from hydrothermal springs and fumaroles located in a volcanic zone of Deception Island, Antarctica. Anion separation was achieved in less than 6 min using indirect UV detection at 254 nm with a negative power supply (−15 kV). The electrolyte consisted of 4.7 mM sodium chromate, 4.0 mM electroosmotic flow modifier (OFM) hydroxide, 10 mM 2-(N-cyclohexylamino)ethanesulfonic acid and 0.1 mM calcium gluconate (pH 9.1). Major anions (Cl, SO42, PO4H2−, and CO3H) were measured using hydrostatic injection (10 cm for 30 s) at 25°C. Trace amounts of anions (F, Br, and NO3) were better determined by electromigration injection (4 kV, 10 s) at 15°C. Good reproducibility of the migration times (<0.72% RSD), a satisfactory linear response and accuracy as well as acceptable detection limits were successfully obtained.  相似文献   

6.
Depending on the sulfur species, picomoles of different inorganic sulfur compounds can be detected and separated by HPLC in one arrangement in a sample volume less than 50 μl. The combination of fluorescence labelling of reduced inorganic sulfur compounds such as sulfide (S2−), sulfite(SO32− and thiosulfate (S2O32−) with monobromobimane followed by an extraction of elemental sulfur (S°) by chloroform treatment enables the detection of all mentioned sulfur compounds as well as sulfate (remaining aqueous phase) in the same sample. While the derivatized sulfur compounds could be detected by their fluorescence emission at 480 nm, elemental sulfur is identified by its UV absorption at 263 nm. Sulfate in the remaining aqueous phase is detected by HPLC with indirect UV detection at 254 nm. Detection ranges for the different sulfur compounds examined are as follows: sulfide (5 μM to 1.5 mM), sulfite (5 μM to 1.0 mM), thiosulfate (1 μM to 1.5 mM), elemental sulfur (2 μM to 32 mM) and sulfate (5 μM to >1 mM).  相似文献   

7.
The modification of silica gel with aluminium by a coating method was very effective for the preparation of silica-based stationary phases which acted as a cation exchanger under strongly acidic conditions. However, the separation of common mono- and divalent cations (Li+, Na+, NH4+, K+, Mg2+ and Ca2+) on an aluminium-adsorbing silica (Al-Silica) column was moderate by a conductimetric detection ion chromatography (IC) with strongly acidic eluents. Then, the addition of various crown ethers (12-crown-4, 15-crown-5 and 18-crown-6) in acidic eluent was carried out. As a result, it was found that 15-crown-5 was most effective for the improvement of peak resolution. Excellent separation of these cations was achieved in 20 min by elution with 2 mM nitric acid–2 mM 15-crown-5. The proposed IC was successfully applied to the determination of major cations in various natural waters.  相似文献   

8.
The retention and detection behavior of common mono- and divalent cations (M+, alkali metal (Li+, Na+, K+, Rb+, Cs+) and ammonium ions (NH4+); M2+, alkaline earth metal ions (Mg2+, Ca2+, Sr2+, Ba2+) was examined using an ODS column (150×4.6 mm I.D.) and conductivity (CD)/UV detection. The results obtained were as follows: (1) for M+, the mobile phase, 0.1 mM sodium dodecyl sulphate (SDS)+10 mM HNO3 and indirect CD detection were effective. (2) Addition of Ce(III) in the mobile phase accelerated the elution of both M+ and M2+. The separation of above 10 cations on an ODS column was achieved for the first time without any coelution of cations and disturbance by system peak. Addition of higher SDS resulted in good separation of M+ and M2+ with longer retention times. CD detection was possible for M+ and M2+ and UV detection for M2+. (3) For M2+, the mobile phase, 0.8 mM Ce(III)+0.1 mM SDS+1 mM HNO3 and indirect UV detection were effective. The IC methods were applied to real samples.  相似文献   

9.
Organic rich natural waters from peat bogs in continental (Switzerland) and maritime (Shetland Islands, Scotland) environments were analysed for Na+, NH4+, K+, Mg2+ and Ca2+ using ion chromatography. These cations were determined simultaneously in surface and pore water samples from the continental bogs using a 250-μl injection loop in an isocratic separation. Using this loop, detection limits of the order of 1 ng/g were achieved. An organics-removal cartridge (Dionex OnGuard P) was used to remove humic materials. Analyses of deionized water filtered through these cartridges showed acceptably low blank values (e.g., ca. 5 ng/g) and appeared to have no significant effect on the measured cation concentration. For the maritime bog waters, the low concentrations of NH4+ (ca. 1 μg/g) compared with Na+ (ca. 100 μg/g) required improved peak separation. This was accomplished using a gradient separation beginning with 40 mM HCl—1 mM , -2,3-diaminopropionic acid monochloride (DAP) and switching to 40 mM HCl-12 mM DAP after 2 min. Using a 25 μl injection loop, Na+, NH4+, K+, Mg2+ and Ca2+ were determined simultaneously in less than 25 min. In this instance, even with Na+/NH4+ > 100, there was no interference from Na+ in the determination of NH4+ (baseline separated).  相似文献   

10.
Application of capillary isotachophoresis (CITP) for the analysis of water extracts of the dust samples collected in different periods in air-filtration devices in Prague car traffic tunnels and in Parisian metro station is presented. The extracts were analyzed in cationic mode with a leading electrolyte (LE) of 10 mM KOH, 25 mM acetic acid, pH 4.4, and a terminating electrolyte (TE) of 10 mM β-alanine, adjusted to pH 4.4 with acetic acid, and in anionic mode with LE 10 mM HCl, 20 mM histidine, pH 5.8 and TE 10 mM 2-(N-morpholino)ethanesulphonic acid, pH 3.7. Extracted amounts of UV-absorbing substances, including pollen allergens and organic pollutants, the number of the found components and concentrations of some inorganic ions (e.g. Cl, K+, Na+, Ca2+) in the dust samples were determined. It was found that the extracted amounts of anionic components and their number were much higher than those of cationic components. Significant differences have been found in the analyses of the extracts of different origin. Much more material and more components were present in the extracts of samples from the pollen-rich period than from the pollen-free period, especially in anionic CITP mode.  相似文献   

11.
A novel bipolar stationary phase (HCPS–MO) was prepared by impregnation of hypercrosslinked polystyrene (HCPS) with methyl orange (MO; 4-dimethylamino-4′-sulfoazobenzene) and its ion-exchange properties were studied. Simultaneous separation of cations and anions on HCPS–MO is possible, although it behaves preferentially as a cation-exchanger. Unusual selectivity of HCPS-MO for alkali and alkaline-earth metal cations: Na++K++4++ and Mg2+2+2+2+ was observed. The effect of temperature on retention of alkali and alkaline-earth metal cations was studied. Separation of Na+, K+, Rb+, NH4+, Cs+, Mg2+ and Ca2+ on HCPS–MO with diluted cerium(III) nitrate solution as an eluent in single run is presented.  相似文献   

12.
Solutions of multiple cations in aqueous solutions at concentrations as low as 200 ppb were analyzed by capillary zone electrophoresis. Aluminum ions were cleanly separated from Li+, K+, Ca2+, Cr3+, Zn2+, CU2+, and other ions less than 6 min after injection of the solution on a 50 cm × 50 μm I.D. uncoated fused-silica capillary column at 15 kV. Indirect detection at 204 nm was carried out using a pH 2.8 background electrolyte containing 5.2 mM ephedrine as a UV-absorbing co-ion and 4.7 mM -hydroxyisobutyric acid as a completing counter ion. Mobilities for Al3+ and 14 other complexed cations were determined for this electrolyte.  相似文献   

13.
A bonded phase capillary column containing macrocyclic polyamine, [28]ane-N6O2 functional groups was used for the electrophoretic separation of arsenic, chromium and selenium species. A simple device interfacing this capillary electrochromatography (CEC) systems to an inductively coupled plasma mass spectrometer (ICPMS) is described. The dimension of the capillary column was 160 cm×100 μm i.d. To accommodate this electrophoretic separation, an auxiliary capillary was used with nitric acid (0.05 M) as makeup liquid. With the electrokinetic method at –20 kV, 20 s and a nebulizer gas flow rate of 1 l min−1, the sample injected was analyzed with an applied potential of −20 kV. The background electrolyte buffer for the separation of CrO42−–Cr3+ was phosphate (20 mM, pH 6.5). That for HAsO42−–Ph4As+ was pyromellitate (20 mM, pH 6.0) and for SeO42−–SeO32− was acetate (20 mM, pH 6.0). The role of the buffer’s anion was also discussed. The separation efficiency of the bonded phase was compared with the bare fused silica. Concentration detection limits for these metal ions were in the low ppb range. In addition, the matrix effect of the established system with the bonded phase was found smaller than that with the bare fused silica.  相似文献   

14.
Aminopolycar☐ylate ligands were added to the 4-(2-pyridylazo)-resorcinol (PAR) postcolumn reagent to alter the reagent selectivity towards transition metals. Addition of ethylenediaminetetraacetic acid (EDTA) completely suppressed the reaction between PAR and the metal ions. Addition of 0.1 mM nitrilotriacetic acid (NTA) to 1 mM PAR lowered the response to specific transition metal ions, but completely suppressed the PAR response to the lanthanides. Increasing the NTA concentration to 8 mM resulted in complete suppression of the PAR response to all metal ions except Cu2+ and Co2+ for which the detection limits were 3 and 1 ng, respectively. The observed selectivity results from the slow rate of conversion of metal ions from the M(NTA)24− form to M(PAR)2.  相似文献   

15.
Hassan SS  Ali MM  Attawiya AM 《Talanta》2001,54(6):1153-1161
Two novel uranyl PVC matrix membrane sensors responsive to uranyl ion are described. The first sensor incorporates tris(2-ethylhexyl)phosphate (TEHP) as both electroactive material and plasticizer and sodium tetraphenylborate (NaTPB) as an ion discriminator. The sensor displays a rapid and linear response for UO22+ ions over the concentration range 1×10−1–2×10−5 mol l−1 UO22+ with a cationic slope of 25.0±0.2 mV decade−1. The working pH range is 2.8–3.6 and the life span is 4 weeks. The second sensor contains O-(1,2-dihydro-2-oxo-1-pyridyl)-N,N,N′,N′-bis(tetra-methylene)uronium hexafluorophosphate (TPTU) as a sensing material, sodium tetraphenylborate as an ion discriminator and dioctyl phenylphosphonate (DOPP) as a plasticizer. Linear and stable response for 1×10−1–5×10−5 mol l−1 UO22+ with near-Nernstian slope of 27.5±0.2 mV decade−1 are obtained. The working pH range is 2.5–3.5 and the life span of the sensor is 6 weeks. Interference from many inorganic cations is negligible for both sensors. However, interference caused by some ions (e.g. Th4+, Cu2+, Fe3+) is eliminated by a prior ion exchange or solvent extraction step. Direct potentiometric determination of as little as 5 μg ml−1 uranium in aqueous solutions shows an average recovery of 97.2±1.3%. Application for the determination of uranium at levels of 0.01–1 wt.% in naturally occurring and certified ores gives results with good correlation with data obtained by X-ray fluorescence.  相似文献   

16.
The objective of this study was to investigate the retention of phosphate anions, H2PO4 and HPO42−, by nanofiltration. The first part of this study deals with the characterisation of the NF200 membrane used in permeation experiments with aqueous solutions of neutral organic and charged inorganic solutes. In the second part the effects of feed pressure, ionic strength, concentration and pH on the retention of phosphate anions were investigated. Results show that the membrane is negatively charged, its pore radius is around 0.5 nm and the retention order for the salts tested was R(Na2SO4) > R(NaCl) > R(CaCl2). The retentions of phosphate anions are in the order of 85% for H2PO4 and 96% for HPO42−. They are relatively high when compared to retentions of other anions with the same charge. The retentions of phosphate anions, particularly the monovalent species, depend on the chemical parameters (feed concentration, ionic strength, and pH) and applied pressure. The experimental data were analysed using the Speigler–Kedem model and the transport parameters, i.e., the reflection coefficient (σ) and solute permeability (Ps) have been determined.  相似文献   

17.
A predominantly localized electron pair scheme is outlined for describing the electron distribution and bonding in closo borane anions BnHn2− and related electron deficient deltahedral clusters, in which a skeletal electron pair is assigned to each vertex, one pair being regarded as delocalized just inside the roughly spherical surface on which the skeletal atoms lie. The scheme gives a clearer picture of the electron distribution than is conveyed by resonating 2- and 3-centre bonds in the polyhedron edges and faces, and allows the bond orders of the polyhedron edge links to be calculated readily. The consequence of formal removal of BH2+ units from closo species BnHn2− to generate nido species Bn−1Hn−14− and arachno species Bn−2Hn−26− is explored, and seen to allow rationalization of two features of such deltahedral-fragment clusters: (i) why a high-connectivity vertex is left vacant and (ii) why the frontier orbitals of such species concentrate electronic charge around their open faces. Moreover, in the case of D4‘h B4H46− (cf. C4H42−) and D5h B5H56− (cf. C5H5), the approach leads directly to the familiar picture for aromatic ring systems in which the highest filled, doubly degenerate π-bonding molecular orbital concentrates electronic charge in rings above and below the polygon on which the skeletal nuclei lie. It also leads to the expectation that arachno clusters with non-adjacent vacant vertices will be more stable than those with adjacent vacant vertices.  相似文献   

18.
Structural and electronic properties of semiconductor binary microclusters AlnPm+ cations have been investigated using the B3LYP–DFT method in the ranges of n=1,2 and m=1–7. Full structural optimization, adiabatic ionization potentials calculation and frequency analysis are performed with the basis of 6-311G(d). The charge-induced structural changes in these cations have been discussed. The strong P–P bond is also favored over Al–P bonds in the AlnPm+ cations in comparison with corresponding neutral cluster. With Pm forming the base, adding Al atom(s) in different positions would find the stable structures of AlnPm+ cations quickly and correctly. Both AlP4+ and AlP6+ are predicted to be species with high stabilities and possible to be produced experimentally.  相似文献   

19.
D. O. M  rtire  M. R. F  liz  A. L. Capparelli 《Polyhedron》1988,7(24):2709-2714
Using the temperature jump technique, the study of the kinetics of the complexing of oxomolybdate anion with malic acid has been carried out in aqueous solutions of pH 7.15–8.5 at ionic strength 0.1 M (KNO3) and 25°'C. A reaction scheme for the formation of 1 : 1 complexes is proposed which accounts for the observed relaxation rates.

The significance of the ligand deprotonation on the complexation reaction of MoO42− by a single protonated ligand, i.e. MoO42−+LHnk→MoO3(OH)Ln−2, (where n = 1 -, 2 -, etc), is analysed on the basis of a simple model. A linear correlation between the log k and the pK of the monoprotonated ligand (LH) is found for this reaction when the global process is controlled by the proton transfer from the ligand to an oxogroup, i.e. log k = a - 0.5xpK. It is found that this correlation is satisfied by MoO42− and WO42−. The experimental slopes for these oxyanions are −0.503 and −0.543 respectively, in agreement with the predictions.  相似文献   


20.
Nickel(II) chromate complex with imidazole (HIm) was isolated from the [Ni2+–HIm–CrO42−] system in various experimental conditions, i.e. reagent molar ratios and nickel(II) salts. The catena(μ-CrO4-O,O′)[Ni(HIm)3H2O] (1) crystallizes in monoclinic crystal system—space group P21/n with cell parameters: a=11.784(2), b=8.899(2), c=13.934(3) (Å), β=95.19(3) (°). The unit cell contains two independent helixes, left- and right-handed, stabilized by intrahelical and interhelical hydrogen bonds (HB) and π–π interactions. The cis coordination of the CrO42− anions and the HB systems appeared to be the main determinants of the helical architecture. To the best of our knowledge the cis-chromate coordination was observed for the first time. The cis coordination causes the distortion of the nickel octahedron, which was analysed by 4 K single crystal electronic spectra with D4h symmetry approximation (gaussian resolution and crystal field parameters). This symmetry was also confirmed with the polarised electronic spectra. The magnetic properties of the complex suggest the occurrence of weak intrachain antiferromagnetic interactions between the magnetic NiII center. The computational DFT studies of complex 1 assuming three possible isomers mer[(HIm)3]–cis[(CrO42−)2], mertrans and faccis suggested that the main contribution to the stability of 1 might have interhelical and intrahelical hydrogen bonds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号