首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
We describe a combination of selected ions as a terminating ion which is useful for transient isotachophoresis (ITP) in capillary zone electrophoresis (CZE) for the determination of nitrite and nitrate in seawater. In addition to 150 mM sulfate as the principal terminating ion, 10 mM bromate was added to a sample solution as the additional terminating ion. Artificial seawater containing 3 mM cetyltrimethylammonium chloride (CTAC) was adopted as a background electrolyte (BGE). The limits of detection (LODs) for nitrite and nitrate were 2.2 and 1.0 microg/L (as nitrogen), respectively. The LODs were obtained at a signal to noise ratio (S/N) of 3. The values of the relative standard deviation (RSD) of peak area for these ions were 1.9 and 1.4%. The RSDs of peak height were 1.7 and 1.9%, the RSDs of migration time 0.11%. The proposed method was applied to the determination of nitrite and nitrate in a proposed certified reference material for nutrients in seawater, MOOS-1, distributed by the National Research Council of Canada (NRC). The results almost agreed with the assigned tolerance interval.  相似文献   

2.
Transient isotachophoresis-capillary zone electrophoresis with artificial seawater as the background electrolyte (BGE) was improved to further lower the limit of detection (LOD) for determination of nitrite and nitrate in seawater. By lowering the pH of BGE, the difference between effective mobility of nitrite and that of nitrate increased, thereby permitting increased sample volumes to be tolerated and their LOD values to decrease. Artificial seawater with pH adjusted to 3.0 using phosphate buffer was adopted as the BGE. To reverse electroosmotic flow (EOF), a capillary was flushed with 0.1 mM dilauryldimethylammonium bromide for 3 min before the capillary was filled with the BGE. Limits of detection (LODs) for nitrite and nitrate were 2.7 and 3.0 microg/l (as nitrogen), respectively. The LODs were obtained at a signal-to-noise ratio of 3. Values of the relative standard deviation (RSD) of peak area for these ions were 2.0 and 0.75%, respectively, when nitrite concentration was 0.05 mg/l and that of nitrate was 0.5 mg/l. The RSDs of peak height were 4.4 and 2.3%. The RSD values of migration time for these ions were 0.19 and 0.17%. The proposed method was applied to determination of nitrite and nitrate in a proposed certified reference material for nutrients in seawater, MOOS-1, distributed by the National Research Council of Canada. Results agreed with the assigned tolerance interval. This method was also applied to determination of these ions in seawater collected around Osaka Bay. Results nearly agreed with those obtained by a conventional spectrophotometric method.  相似文献   

3.
We have examined transient isotachophoresis (ITP) conditions, e.g. the nature of the terminating ion, its concentration, and the injection procedure, to improve the limit of detection (LOD) for determination of nitrite and nitrate in seawater by capillary zone electrophoresis (CZE). Artificial seawater containing 3.0 mmol L(-1) cetyltrimethylammonium chloride (CTAC) was used as background electrolyte (BGE). After sample injection 600 mmol L(-1) acetate was separately injected into the capillary as the terminating ion for transient ITP. The LOD for nitrite and nitrate, obtained at a signal-to-noise ratio (S/N) of 3, were 15 and 7.0 microg L(-1) (as nitrogen), respectively. Relative standard deviations (RSD) of peak area for nitrite and nitrate were 7.3 and 0.8%, respectively, and the RSD of peak height were 5.7 and 1.2%, respectively, when the concentrations of nitrite and nitrate were 0.05 and 0.25 mg L(-1). The RSD of migration time for these ions was 0.2%. The proposed method was applied to the determination of nitrite and nitrate in seawater samples. The results for nitrite were nearly in agreement with those obtained by naphthylethylenediamine spectrophotometric analysis (SPA; correlation coefficient 0.9041).  相似文献   

4.
We describe capillary zone electrophoresis (CZE) with transient isotachophoresis (ITP) for the determination of low concentrations of nitrite and nitrate ions in seawater. Bromide-free artificial seawater was adopted as background electrolyte (BGE) to eliminate the interference of high concentrations of salts in seawater. To reverse the electroosmotic flow (EOF), 3 mM cetyltrimethylammonium chloride (CTAC) was added to the BGE. High concentrations of chlorate were added to sample solutions as the terminating ion to generate the ITP process before the CZE separation. In general, the stacking effect increased with increasing amounts of chlorate injected into the capillary. The limits of detection (LODs) for nitrite and nitrate were 0.063 and 0.033 mg/L when the chlorate concentration was 600 and 200 mM, respectively; these were half of those obtained by CZE without the transient ITP. The LODs were obtained at a signal to noise ratio (S/N) of 3. The relative standard deviations (RSD, n = 10) of the peak areas for these ions were 3.2 and 2.9%. The RSDs of peak heights for these ions were 1.6 and 2.1%. The RSDs of migration times for these ions were 0.67 and 0.46%.  相似文献   

5.
Ion-exchange chromatography using a high-capacity anion exchanger with UV detection was applied to the determination of nitrate in seawater. Major ions in seawater samples did not affect the peak shape and the retention time of the nitrate when an alkaline metal cation-chloride solution was used as an eluent at high concentrations (0.5-2 mol/l). At a wavelength of 220 nm, the peak of bromide was very small because of low absorption, while its separation from the nitrate peak was good at high concentrations. Among the eluents tested, lithium chloride gave the best separation of nitrate from bromide. It was estimated that the lithium ion had the least potential for ion-pair formation with nitrate, and its retention time was prolonged compared with the retention times when using other cations; with bromide and nitrite, such an effect was not observed. The results of shipboard seawater nitrate determination by our method in the South Pacific Ocean and Antarctic Sea showed good agreement with those by the conventional photometric method using continuous flow.  相似文献   

6.
We describe an application of capillary zone electrophoresis (CZE) with transient isotachophoresis (ITP) as the on-line concentration procedure for the determination of iodide in seawater. The effective mobility of iodide was decreased by the addition of 10 mM cetyltrimethylammonium chloride (CTAC) to an artificial seawater background electrolyte (BGE) so that transient ITP functioned and iodide was separated from other coexisting anions such as bromide, nitrite, and nitrate in seawater samples. After sample injection, 600 mM acetate was separately injected into the capillary as the terminating ion to generate transient ITP. The limit of detection (LOD) for iodide was 3.0 microg/L. The LOD was obtained at a signal-to-noise ratio (S/N) of 3. The values of the relative standard deviation (RSD) of peak area, peak height, and migration time for iodide were 2.9, 2.1, and 0.6%. The proposed method was applied to the determination of iodide in seawater collected around the Osaka Bay. The results obtained by use of the calibration graph were agreed with those obtained by the addition of the standard solutions for iodide.  相似文献   

7.
Conventional silica columns dynamically modified with cetyltrimethylammonium ions were evaluated for the determination of UV-absorbing bromide, nitrate, and nitrite in seawater samples. Cetyltrimethylammonium, which is a quaternary ammonium ion, was dynamically introduced onto silica surfaces. The first layer of the modifier was introduced by electrostatic interaction, whereas the second layer was introduced by hydrophobic interaction. The latter layer worked as the anion-exchange sites. The modified conventional silica columns could be used for separation of inorganic anions. Separation of authentic mixture of five anions was achieved within 17 min. The addition of 0.1 mM cetyltrimethylammonium ion to the eluent improved the repeatability of the retention time. Seawater samples could be directly injected onto the prepared conventional silica columns, and bromide, nitrate, and nitrite levels were determined to be 69, 0.13, and 0.016 ppm, respectively.  相似文献   

8.
A rapid and simple capillary electrophoretic method was developed for the direct determination of bromide ion in seawater. We have found an effective method, based on the use of polyethyleneimine-coated capillaries and the addition of sodium chloride to the background electrolyte. The use of coated capillaries with a cationic polymer changes the direction of the electroosmotic flow in the capillary, which favors the migration speed of the bromide ion and enables the use of low salt concentrations in the separation electrolyte. Bromide ion in seawater can be determined within 2 min using this system and 20 mmol L-1 NaCl-containing separation electrolyte. The detection limit for the bromide ion was 0.45 g ml-1. The method was applied to the determination of bromide ion in seawater samples collected from the Bosphorus and the Black Sea. Bromide contents in samples from 0 to 72 m depths varied between 33.2 and 72.8 mg L-1 with a mean 3.0% RSD.  相似文献   

9.
A fast and highly sensitive ion chromatographic method using monolithic ODS columns was developed for the determination of nitrite (NO2-) and nitrate (NO3-) in seawater. Two monolithic ODS columns (50 mm x 4.6 mm i.d. + 100 mm x 4.6 mm i.d.) connected in series were coated and equilibrated with 5 mM cetyltrimethylammonium chloride (CTAC) aqueous solution. The column efficiency with 0.5 M NaCl as the mobile phase did not decrease in spite of the increase in flow rate of the mobile phase. Thus, good chromatograms were obtained within 3 minutes for NO2- and NO3 in artificial seawater without interferences by coexisting ions. The detection limit (S/N = 3) with UV detection at 225 nm was 0.8 and 1.6 microg/L for NO2- and NO3-, respectively. The characteristics of the monolithic CTA(+)-coated ODS columns were discussed. The present method was successfully applied to the fast and sensitive determination of NO2- and NO3- in real seawater samples.  相似文献   

10.
Woodland MA  Lucy CA 《The Analyst》2001,126(1):28-32
A new method for altering the selectivity of inorganic anion separations in capillary electrophoresis is described. Addition of the zwitterionic surfactant 3-(N,N-dimethyldodecylammonio)propane sulfonate (DDAPS) to the background electrolyte modifies the migration order via electrostatic ion chromatography type interactions. Variation of the DDAPS surfactant concentration from 4 to 120 mM monotonically alters the selectivity from electrophoretic mobility based to that of electrostatic ion chromatography, without increasing Joule heating. This technique was applied to the determination of nitrate, nitrite, bromide and iodide in artificial seawater. Detection limits for the anions in 1:5 diluted seawater were 11, 5, 7 and 11 microM, respectively.  相似文献   

11.
Suzuki A  Lim LW  Hiroi T  Takeuchi T 《Talanta》2006,70(1):190-193
Monolithic silica capillary columns dynamically modified with quaternary ammonium ions were evaluated for the determination of bromide in seawater samples. A quaternary ammonium ion such as cetyltrimethylammonium ion was dynamically introduced onto monolithic silica surfaces. The first layer of the modifier was introduced by electrostatic interaction, whereas the second layer was introduced by hydrophobic interaction. The latter layer worked as the anion-exchange sites. The modified monolithic silica capillary columns could be used for rapid separation of inorganic anions. Separation of authentic mixture of five anions was achieved within a few minutes. The addition of small amount of the modifier in the eluent improved the repeatability of the retention time. Seawater samples could be directly injected onto the prepared capillary columns, and bromide could be determined to be 63 mg/L.  相似文献   

12.
A simple method for the determination of nitrite and nitrate in human plasma has been developed using CZE with minimal sample preparation. Field‐amplified sample stacking (FASS) was used to achieve submicromolar detection by dilution of the plasma sample with deionized water. In CZE, the separation of nitrite and nitrate was achieved within 10 min without adding EOF modifier. The optimal condition was achieved with 50 mM phosphate buffer at pH 9.3. The ninefold diluted plasma samples were injected hydrodynamically for 40 s into a 60 cm×75 μm id uncoated fused‐silica capillary. The separation voltage was 20 kV (negative potential) and UV detection was performed at 214 nm. The linearity curves for nitrite and nitrate were obtained by the standard addition method. The estimated LODs for nitrite and nitrate in ninefold diluted plasma sample were 0.05 and 0.07 μM, respectively. The LODs for nitrite and nitrate in original plasma samples were 0.45 and 0.63 μM. The intra‐ and inter‐day precisions for both analytes were <2.6% and the recovery ranged between 92.3 and 113.3%. It was found that nitrite was more stable than nitrate in the plasma after the sample preparation. This proposed method was applied to a number of human plasma samples and the measured nitrite and nitrate concentrations in human plasma were consistent with the literature ranges.  相似文献   

13.
On-line ion-exchange preconcentration, performed in a flow injection analysis system, has been integrated with capillary electrophoresis via a specially designed interface, and a sensitive and selective method for the determination of nitrite, nitrate, bromide and iodide using direct UV absorbance detection has been developed. Fivefold enrichment of these aforementioned anions can be realised. Separation conditions such as carrier electrolyte and concentration of electroosmotic modifier were investigated. Limits of detection were ca. 10 ng ml−1 for nitrite and nitrate in aqueous samples, and the overall relative standard deviation was about 5%.  相似文献   

14.
基于苯胺与亚硝酸盐的重氮化反应及反应产物与甲萘酚的显色,借助流动分析技术,实现了海水中苯胺含量的分析测定。体系以30.9g/L的NaCl做载液、人工海水配制标准样品,对各个影响因素进行了优化。苯胺浓度在0.01~1.0mg/L范围内与相对峰高呈线性关系,线性方程ΔH(mV)=200.53ρ+1.0728(n=8,ρ为苯胺浓度mg/L),相关系数R2=0.9982。方法的检出限(3σ)为0.005mg/L,相对标准偏差(RSD)为4.8%(n=11)。考察了共存离子、不同盐度样品对分析测定的影响。用于实际海水样品的分析,回收率为95.8%~106.6%。  相似文献   

15.
Capillary zone electrophoresis is proposed for the determination of magnesium and calcium ions in seawater. A carrier solution containing EDTA was adopted for the complexation of these ions and the effect of sodium chloride concentration in the sample solutions on the results was examined. It was found that magnesium and calcium ions could be determined without any pretreatment by injecting 100-fold diluted seawater samples. Linear calibration graphs were obtained for standard solutions containing up to 10.0 mg/l of calcium ion when both peak area and peak height were used. On the other hand, a linear calibration graph was obtained for standard solutions containing up to 20.0 mg/l of magnesium ion when the peak area was used, while a curved one was obtained when the peak height was used. Relative standard deviations were 0.8 and 1.2% when a standard solution containing 5.0 mg/l of magnesium and 8.0 mg/l of calcium ions was analysed 8 times using the peak area. Limits of detection for magnesium and calcium ions were 0.13 and 0.26 mg/l, respectively. The proposed method was applied to the determination of magnesium and calcium ions in surface and bottom seawater samples.  相似文献   

16.
An electrostatic ion chromatographic (IC) method for rapid and direct determination of iodide in seawater is reported. Separation was achieved using a reversed-phase ODS packed column (250x4.6 mm I.D.) modified by coating with Zwittergent-3-14 micelles, with an eluent comprising an aqueous solution containing 0.2 mM NaClO4 and 0.3 mM Zwittergent-3-14 and using UV detection at 210 nm. Samples prepared by dissolving NaIO3, NaNO2, NaBr, NaBrO3, NaNO3, NaI, and NaSCN in artificial or real seawaters were analyzed using this IC system. Nitrite, iodate, bromide, bromate, and nitrate showed very little or no retention, while iodide and thiocyanate were well separated, being eluted within 6 and 16 min, respectively. The detection limit for iodide obtained by injecting 400 microL of sample was 0.011 microM (S/N = 3), and the precision values obtained by analyzing samples containing 0.1 or 0.3 microM iodide in real seawater samples were 2.3% RSD and 1.2% RSD, respectively. Direct determination of iodide in real seawater samples was possible using this proposed IC system.  相似文献   

17.
毛细管离子电泳法同时测定腌菜中硝酸根和亚硝酸根   总被引:3,自引:0,他引:3  
以溴离子(Br-)为内标,建立了毛细管离子电泳同时测定腌菜中的硝酸根和亚硝酸根的方法。讨论了缓冲液pH、样品和缓冲液中氯化钠浓度、分离电压对分离的影响。结果表明:以含1mol LNaCl的40mmol LH3PO4 NaOH缓冲-、-得到基线分离。NO3-和NO2液(pH3.5)为背景电解质,4min内Br-、NO3-检出限分别为0.1g L和0.3g L,峰面积相对标准偏差分别为4.6%和NO25 8%。  相似文献   

18.
A rapid method for the determination of nitrate and nitrite ions is described. The potential of a mixture of nitrate and nitrite was measured with a nitrate ion selective electrode. The nitrite in the mixture is then oxidized to nitrate with permanganate in acid solution, and the potential of the oxidized solution is also measured with the electrode. The fundamental equations for the response of the nitrate ion electrode to nitrate ion in the presence of interfering ions were used, and a new equation was developed for calculating the original nitrate concentration of the mixture. The absolute errors for solutions of known concentrations (2.5–100 p.p.m. each) were 1.8 p.p.m. nitrate and 2 p.p.m. nitrite. When the results are calculated by computer, five determinations can be performed in 30 min. The method was applied to the determination of the oxides of nitrogen in cigarette smoke as nitrite and nitrate after dissolution in basic solution.  相似文献   

19.
A simple flow-based procedure with chemiluminescence (CL) detection is proposed for bromide ion determination in seawater. The procedure was based on the oxidation of bromide to bromine by chloramine-T followed by the reaction of bromine with luminol resulting in CL emission. Since no significant reaction within chloramine-T and luminol was observed, the detection was carried out without bromine extraction from the oxidant medium. The proposed flow system had a sampling rate of 40 determinations per hour, reagents consumption of 100 μg luminol and 60 μg chloramine-T per determination, a limit of detection of 0.5 mg l−1 bromide ions, a linear concentration range (r = 0.999 and n = 7) between 0 and 100 mg l−1, and a coefficient of variance better than 2.5% (for 10 measurements of a 10 mg l−1 Br solution) were achieved. The analytical system was applied for the determination of bromide in seawater and estuarine-water samples, obtaining an analyte recovery ranging from 94 to 102% and comparing the results with a reference spectrophotometric method no significant difference was observed in 95% confidence level.  相似文献   

20.
The rapid separation of inorganic anions was determined by capillary ion chromatography using monolithic silica capillary columns modified with dilauryldimethylammonium bromide. The stability of the modified stationary phase was satisfactory owing to a strong hydrophobic interaction between the lauryl groups of the reagent, even if the eluent did not contain dilauryldimethylammonium ion. Bromide in seawater samples could be determined by the present system. The repeatability of a retention time of bromide for six successive measurements was around 1.8% when a 500 mM sodium chloride aqueous solution was used as the eluent. Seawater samples were directly injected onto the prepared column without any interference of matrix ions, because an aqueous solution of high-concentration sodium chloride could be used as the eluent. Bromide in seawater samples could be determined within 2 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号