首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
The PB film-modified electrode was used as an amperometric detector for flow injection analysis of ascorbic acid. The modified electrode detector showed good sensitivity, stability and reproducibility. The calibration curve for ascorbic acid was linear over the concentration range from 5.0x10(-6) to 1.0x10(-3) mol l(-1) with a slope of 19.9 mA mol(-1) per litre and a correlation coefficient of 0.999. The detection limit of this method was 2.49x10(-6) mol l(-1). The relative standard deviation of six replicate injections of 2.5x10(-4) mol l(-1) ascorbic acid was 2.5%. The results obtained for ascorbic acid determination in pharmaceutical products are in good agreement with those obtained by using the procedure involving the reaction between triiodide and ascorbic acid.  相似文献   

2.
3.
Raj CR  Kitamura F  Ohsaka T 《The Analyst》2002,127(9):1155-1158
The self-assembled monolayer of a heterocyclic thiol, mercaptobenzimidazole (MBI) on gold (Au) electrode is successfully utilized for the voltammetric sensing of uric acid (UA). The self-assembly of MBI separates the voltammetric signal of UA from the interfering ascorbate (AA). Selective detection of UA in the presence of a large excess of AA or the simultaneous detection of UA and AA is achieved at the MBI monolayer-modified electrode. This electrode can detect as low as 1 microM of UA in the presence of 100-fold excess of AA with excellent reproducibility. The practical utility of the electrode is demonstrated by measuring the concentration of UA in human serum.  相似文献   

4.
The present work reports a quercetin-modified wax-impregnated graphite electrode (Qu/WGE) prepared through an electrochemical oxidation procedure in quercetin-containing phosphate buffer solution (PBS), for the purpose of detecting uric acid (UA) in the presence of ascorbic acid (AA). During modification quercetin was oxidized to the corresponding quinonic structure, and in the blank buffer solution the electrodeposited film exhibits a voltammetric response anticipated for the surface-immobilized quercetin. Retarding effect of the film towards the reaction of anionic species was found; therefore the pH of sample solutions was selected to ensure the analyte in molecular form. At suitable pHs the Qu/WGE shows excellent electrocatalytic effect towards the oxidation of both AA and UA, and separates the voltammetric signal of UA from AA by about 280 mV, allowing simultaneous detection of these two species. A linear relation between the peak current and concentration was obtained for UA in the range of 1-50 μM in the presence of 0.5 mM AA, with a detection limit 1.0 μM (S/N = 3). This sensor was stable, reproducible and outstanding for long-term use.  相似文献   

5.
Nanocrystalline graphite-like pyrolytic carbon film (PCF) electrode fabricated by a non-catalytic chemical vapor deposition (CVD) process was used for the simultaneous electrochemical sensing of ascorbic acid (AA), dopamine (DA), and uric acid (UA). The electrode was studied with respect to changes in electrocatalytic activity caused by a simple and fast electrochemical pretreatment. The anodized electrode exhibited excellent performance compared to many chemically modified electrodes in terms of detection limit, linear dynamic range, and sensitivity. Differential pulse voltammetry (DPV) was used for the simultaneous determination of ternary mixtures of DA, AA, and UA. Under optimum conditions, the detection limits were 2.9 μM for AA, 0.04 μM for DA, and 0.03 μM for UA with sensitivities of 0.078, 5.345, and 6.192 A M−1, respectively. The peak separation was 219 mV between AA and DA and 150 mV between DA and UA. No electrode fouling was observed and good reproducibility was obtained in all the experiments. The sensor was successfully applied for the assay of DA in an injectable drug and UA in human urine by using standard addition method.  相似文献   

6.
Maki T  Soh N  Nakano K  Imato T 《Talanta》2011,85(4):1730-1733
A simple and sensitive flow injection fluorometric method for the determination of ascorbic acid is described. Perylenebisimide-linked nitroxide (PBILN) is used as a fluorescent reagent, which permits the selective determination of ascorbic acid. The fluorescence of the perylenebisimide moiety in PBILN is quenched by the nitroxide moiety, which is linked to the perylenebisimide. When a stream of a solution of ascorbic acid is merged with a stream of PBILN, the ascorbic acid reacts with the nitroxide moiety of PBILN to form hydroxylamine, and the fluorescence properties of the perylenebisimide moiety are recovered. As a result, a peak-shaped fluorescence signal is produced, which can be observed by a fluorescence detector located downstream. Under optimized conditions, a good linear relationship between the concentration of ascorbic acid and peak height in the concentration range from 0.5 to 10 μmol L−1 was found and the detection limit (S/N = 3) was 0.28 μmol L−1. The relative standard deviation for the determination of 4.0 μmol L−1 ascorbic acid samples was 1.0% (n = 5). The proposed method was applied to the determination of ascorbic acid in several soft drink beverages and the analytical results were in good agreement with those obtained using a conventional method.  相似文献   

7.
The electrochemical behaviors of uric acid (UA) at the penicillamine (Pen) self-assembled monolayers modified gold electrode (Pen/Au) have been studied. The Pen/Au electrode is demonstrated to promote the electrochemical response of UA by cyclic voltammetry (CV). The diffusion coefficient D of UA is 6.97 × 10−6 cm2 s−1. In differential pulse voltammetric (DPV) measurements, the Pen/Au electrode can separate the UA and ascorbic acid (AA) oxidation potentials by about 120 mV and can be used for the selective determination of UA in the presence of AA. The detection limit was 1 × 10−6 mol L−1. The modified electrode shows excellent sensitivity, good selectivity and antifouling properties.  相似文献   

8.
 In flow injection analysis (FIA) of ascorbic acid, methylene green (MG) modified carbon paste electrodes showed high catalytic activity and stability, reducing the oxidation overpotential by 400 mV. The linear response range was over 3 orders of magnitude and the detection limit was 1×10-8 mol/L eq. 0.25 pmol with S/N=3. The influence of various experimental conditions was explored for optimum analytical performance. Received: 2 January 1996/Accepted: 23 January 1996  相似文献   

9.
 In flow injection analysis (FIA) of ascorbic acid, methylene green (MG) modified carbon paste electrodes showed high catalytic activity and stability, reducing the oxidation overpotential by 400 mV. The linear response range was over 3 orders of magnitude and the detection limit was 1×10-8 mol/L eq. 0.25 pmol with S/N=3. The influence of various experimental conditions was explored for optimum analytical performance. Received: 2 January 1996/Accepted: 23 January 1996  相似文献   

10.
Murthy AS  Sharma J 《Talanta》1998,45(5):951-956
A benzoquinone modified basal plane pyrolytic graphite electrode shows electrocatalytic activity for the oxidation of NADH and ascorbic acid in phosphate buffer (pH 7.3). The modified electrode shows a linear variation of catalytic current with concentration in the range 1-10 mM for both NADH and ascorbic acid. The rate constants have been estimated from the surface coverage data.  相似文献   

11.
Yebra-Biurrun MC 《Talanta》2000,52(3):367-383
A review with 100 references is presented to show the advantages involved in the use of flow injection analysis (FIA) for the determination of ascorbic acid. The FI methods proposed for the determination of ascorbic acid are described and compared according to the used detection technique. Analytical figures of merit and interferences are also discussed.  相似文献   

12.
A new approach towards a voltammetric electronic tongue has been developed. Automation of the system was achieved by the use of a sequential injection analysis (SIA) system. Design and construction of a small detection device containing 3 working electrodes was carried out. Platinum, gold and epoxy-graphite discs were used for this purpose. An Ag/AgCl reference electrode was integrated into the measuring cell in order to minimise electrical noise. Three oxidisable compounds of clinical interest i.e., ascorbic acid, uric acid and paracetamol, could be quantified by the system. Employing the voltammograms as departure information, artificial neural networks (ANN) have been used as chemometric tool for the modelling of the system.  相似文献   

13.
Differential pulse and cyclic voltammetry were applied for the oxidation of mixture of uric acid and ascorbic acid at the surface of carbon paste/cobalt Schiff base composite electrode. The electrooxidation of these compounds at bare electrode is sluggish, and there is no suitable peak separation between them. However, using cobalt methyl salophen as modifier, two well-defined anodic waves with a considerable enhancement in the peak current and a remarkable peak potential separation near 315 mV are obtained. It can improve the kinetics of electron transfer for both compounds remarkably. All these improvements are created because of the electrocatalytic property of cobalt Schiff base complex. The effect of some parameters such as pH and scan rates were studied. All the anodic peak currents for the oxidation of ascorbic acid and uric acid shifted toward more negative potential with an increase in pH, revealing that protons have taken part in their electrode reaction processes. The best peak separation with appropriate current was obtained for pH 4.0. A linear range of 5.0?×?10?4 to 1.0?×?10?8 and 1.0?×?10?3 to 1.0?×?10?8 M with detection limit of 8.0?×?10?9 and 8.0?×?10?9 M was obtained for ascorbic acid and uric acid using differential pulse voltammetry at the surface of modified electrode, respectively. Analytical utility of the modified electrode has been examined successfully using human urine samples and vitamin C commercial tablets.  相似文献   

14.
This paper describes the simultaneous determination of ascorbic acid (AA), norepinephrine (NE) and uric acid (UA) using a graphene modified glassy carbon electrode (GME) in pH 4.0 phosphate buffer solution. The electrochemical behaviors of AA, NE and UA at a bare glassy carbon electrode (GCE) and the GME were studied by cyclic voltammetry. Bare GCE failed to resolve the voltammetric signals of AA, NE and UA in a mixture, whereas the GME not only resolved their voltammetric signals, but also exhibited excellent electrocatalytic activity towards their electrochemical oxidation. The oxidation peak currents of AA, NE and UA were linearly proportional to their concentrations over the range of 1.0.0–1000.0, 0.6–45.0 and 1.0–100.0 μM, respectively, and their detection limits were 1.2, 0.10 and 0.60 μM, respectively, The modified electrode is of excellent sensitivity and selectivity, and has been satisfactorily used for the simultaneous determination of AA, NE and UA in their ternary mixture.  相似文献   

15.
A graphene-modified glassy carbon electrode was obtained via drop-casting method and applied to the simultaneous detection of epinephrine, uric acid, and ascorbic acid by cyclic voltammetry in a phosphate buffer solution (pH 3.0). The oxidation potentials of epinephrine, uric acid, and ascorbic acid were 0.484, 0.650, and 0.184 V at the graphene-modified glassy carbon electrode, respectively. The peak separation between epinephrine Pand uric acid, epinephrine and ascorbic acid, and uric acid and ascorbic acid was about 166, 300, and 466 mV, respectively. So, this graphene-modified electrode can be used for simultaneous determination of each component in a mixture.  相似文献   

16.
Dimercaptothiadiazole compound, 2,5-dimercapto-1,3,4-thiadiazole (DMcT) forms ‘thin’ monolayers on Au electrode when it was adsorbed from methanol, ethanol or DMSO solutions while it forms ‘thick’ layers on Au electrode from an aqueous solution under identical experimental conditions. Thick DMcT layers formed from aqueous solution effectively blocks the redox reaction of couple in contrast to thin DMcT monolayers. The monolayer thickness did not vary when structurally related DMcT compounds, 5-methyl-1,3,4-thiadiazole-2-thiol or 5-amino-1,3,4-thiadiazole-2-thiol was adsorbed from aqueous and non-aqueous solutions. This indicates that the presence of two thiol groups in DMcT plays a crucial role in the formation of thick and thin DMcT layers on Au electrode when it was adsorbed from aqueous and non-aqueous solutions. Methanol, ethanol, or DMSO solution of DMcT is considered as strong acid because these solvents are able to deprotonate DMcT into DMcT and thus thin monolayers formed on Au electrode. The deprotonating ability of these solvents was further verified from the observed absorption spectrum characteristic of DMcT species. On the other hand, an aqueous solution of DMcT is less acidic due to weak deprotonation of DMcT by water and thus DMcT forms thick layer on Au electrode. Interestingly, thin DMcT monolayers formed from non-aqueous solvents separates the voltammetric signals of uric acid and ascorbic acid while thick DMcT layers formed from aqueous solution fails to separate them.  相似文献   

17.
A Nafion/multi-wall carbon nanotubes (MWNT) composite film-modified electrode was fabricated. The modified electrode showed excellent electrocatalytic activity toward ascorbic acid (AA) and uric acid (UA) in 0.1-mol L−1 NaCl medium (pH 6.5). Compared to the bare electrode that only displayed a broad and overlapped oxidation peak, the Nafion/MWNT film-modified electrode not only remarkably enhanced the anodic peak currents of AA and UA but also avoided the overlapping of the anodic peaks of AA and UA with a 320-mV separation of both peaks. Under the optimized conditions, the peak currents of AA and UA were proportional to their concentration at the ranges of 8.0 × 10−5 to 6.0 × 10−3 mol L−1 and 6.0 × 10−7 to 8.0 × 10−5 mol L−1, respectively. The proposed method was used for the detection of AA and UA in real samples with satisfactory results.  相似文献   

18.
Palraj Kalimuthu 《Talanta》2010,80(5):1686-319
This paper describes the simultaneous determination of ascorbic acid (AA), dopamine (DA), uric acid (UA) and xanthine (XN) using an ultrathin electropolymerized film of 2-amino-1,3,4-thiadiazole (p-ATD) modified glassy carbon (GC) electrode in 0.20 M phosphate buffer solution (pH 5.0). Bare GC electrode failed to resolve the voltammetric signals of AA, DA, UA and XN in a mixture. On the other hand, the p-ATD modified electrode separated the voltammetric signals of AA, DA, UA and XN with potential differences of 110, 152 and 392 mV between AA-DA, DA-UA and UA-XN, respectively and also enhanced their oxidation peak currents. The modified electrode could sense 5 μM DA and 10 μM each UA and XN even in the presence of 200 μM AA. The oxidation currents were increased from 30 to 300 μM for AA, 5 to 50 μM for DA and 10 to 100 μM for each UA and XN, and the lowest detection limit was found to be 2.01, 0.33, 0.19 and 0.59 μM for AA, DA, UA and XN, respectively (S/N = 3). The practical application of the present modified electrode was demonstrated by the determination of AA, UA and XN in human urine samples.  相似文献   

19.
Almuaibed AM  Townshend A 《Talanta》1992,39(11):1459-1462
Flow injection methods for the individual and simultaneous determination of ascorbic acid and uric acid are proposed. A spectrophotometer and a miniamperometric detector are connected in sequence. The calibration graphs for uric acid obtained by measuring its absorbance at 293 nm and its current at +0.6 V are linear up to at least 80 and 70 mug/ml, respectively, with an rsd (n = 10) of 1 % for both methods at mid-range concentrations. The calibration graph for ascorbic acid with amperometric detection is linear up to 80 mg/l. with an rsd (n = 10) of 0.8% at 30 mg/l. The simultaneous determination of uric acid and ascorbic acid is based on measurement of the absorbance of uric acid at 393 nm and amperometric determination of both analytes at +0.6 V. The average relative errors of the analysis of binary mixtures of uric acid and ascorbic acid are 2.2 and 4.2%, respectively.  相似文献   

20.
A novel amperometric sensor for uric acid based on ordered mesoporous carbon modified pyrolytic graphite electrode was developed. Uric acid oxidation was easily catalyzed by this electrode in a phosphate buffer solution at pH 7.0, with an anodic potential decrease about 140 mV compared to bare pyrolytic graphite electrode. The uric acid level was determined by the amperometric method, at a constant potential of 0.31 mV, the catalytic current of uric acid vs. its concentration showed a good linearity in the range of 1.0 × 10−6−1.0 × 10−4 mol L−1, with a correlation coefficient of 0.999. The detection limit was 4.0 × 10−7 mol L−1. The proposed method could be effectively used for uric acid amperometric sensing in human urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号