首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An interlaboratory validation study funded by the European Commission, Directorate General for Health and Consumer Protection (DG SANCO), was conducted to evaluate the effectiveness of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of semicarbazide (SEM) in different types of baby food at a possible future European regulatory limit (10 ng/g). The test portion of the sample was extracted with hydrochloric acid, and the analyte was derivatized with 2-nitrobenzaldehyde, with 1,2-[15N2, 13C] SEM as an internal standard. The extract was neutralized and then purified on a solid-phase extraction cartridge. The SEM was determined by reversed-phase LC with detection by MS/MS. Apple puree, rice pudding, and meat/vegetable meal baby food materials, spiked with SEM at levels of about 3, 10, and 30 ng/g, respectively, were sent to 20 laboratories in 12 different European countries, which submitted results from 17 participants. Recoveries ranged from 88.8 to 106.1%. Based on results for spiked samples (blind pairs at 3 levels), the relative standard deviations for repeatability (RSDr) ranged from 4.2 to 6.9% and the relative standard deviations for reproducibility (RSDR) ranged from 16.6 to 24.3%. The method showed acceptable within- and between-laboratory precision for all 3 matrixes, as evidenced by HorRat values, at the target levels for the determination of SEM.  相似文献   

2.
A simple and inexpensive liquid chromatography/mass spectrometry (LC/MS) method was developed for the quantitation of acrylamide in various food products. The method involved spiking the isotope-substituted internal standard (1-C13 acrylamide) onto 6.00 g of the food product, adding 40 mL distilled/deionized water, and heating at 65 degrees C for 30 min. Afterwards, 10 mL ethylene dichloride was added and the mixture was homogenized for 30 s and centrifuged at 2700 x g for 30 min, and then 8 g supernatant was extracted with 10, 5, and 5 mL portions of ethyl acetate. The extracts were combined, dried with sodium sulfate, and concentrated to 100-200 microL. Acrylamide was determined by analysis of the final extract on a single quadrupole, bench-top mass spectrometer with electrospray ionization, using a 2 mm id C18 column and monitoring m/z = 72 (acrylamide) and m/z = 73 (internal standard). For difficult food matrixes, such as coffee and cocoa, a solid-phase extraction cleanup step was incorporated to improve both chromatography and column lifetime. The method had a limit of quantitation of 10 ppb, and coefficients of determination (r2) for calibration curves were typically better than 0.998. Acceptable spike recovery results were achieved in 11 different food matrixes. Precision in potato chip analyses was 5-8% (relative standard deviation). This method provides an LC/MS alternative to the current LC/MS/MS methods and derivatization gas chromatography/mass spectrometry methods, and is applicable to difficult food products such as coffee, cocoa, and high-salt foods.  相似文献   

3.
A new method based on matrix solid-phase dispersion (MSPD) on-line with a solid-phase extraction (SPE) cleanup process followed by liquid chromatography with tandem mass spectrometry (LC/MS/MS) is presented for the determination of 3 macrocyclic lactone mycotoxins in fish tissues: zearalenone, alpha-zearalenol, and beta-zearalenol. The sample was prepared in a device that used a reversed-phase material (C18) or a normal-phase material (neutral alumina) as a matrix dispersing agent, and a graphitized carbon black cartridge was used for sequential cleanup by SPE. LC/MS/MS was used for selective determination. Isocratic elution with acetonitrile-methanol-water was used for LC separation; for MS/MS, 2 types of interfaces (a pneumatically assisted electrospray ionization interface or an atmospheric pressure chemical ionization interface) were evaluated and compared in terms of the intensity of the total ion current produced by each analyte. The use of highly selective MSPD on-line with SPE for sample preparation before analysis allowed the removal of interfering matrix compounds present in tissue extracts that would otherwise cause severe ionization suppression of zearalenone and its metabolites during the ionization process. Average recoveries at 100 ng/g were between 83 and 103% with C18 and > or = 67% with neutral alumina; the relative standard deviations were < 11% with C18 and < 18% with alumina. The limits of detection ranged from 0.1 to 1.0 ng/g. Sample preparation is simple to perform, no special technical equipment is required, and solvent volumes are minimal.  相似文献   

4.
The applicability of a rapid and easy multiresidue method for determination of pesticide residues in agricultural products by using liquid chromatography/tandem mass spectrometry (LC/MS/MS) was examined. Pesticide residues were extracted with acetonitrile in a disposable tube using a homogenizer, followed by salting out with anhydrous magnesium sulfate and sodium chloride. The extract was purified with a double-layered cartridge column (graphite carbon black/primary-secondary amine silica gel). After removal of the solvent, the extract was resolved in methanol-water and analyzed with LC/MS/MS. Recovery tests of 99 pesticide residues from 7 agricultural products were performed at 20 and 100 ng/g. Throughout all of the agricultural products tested, 47 pesticides exhibited satisfactory recoveries (70-120%) and relative standard deviations (<20%) at both concentrations. The time for processing of 12 samples to test solutions was approximately 2-3 h. This method could be useful for determination of pesticide residues in agricultural products.  相似文献   

5.
Presence of matrix ions could negatively affect the sensitivity and selectivity of liquid chromatography‐tandem mass spectrometer (LC‐MS/MS). In this study, the efficiency of a miniaturized silica monolithic cartridge in reducing matrix ions was demonstrated in the simultaneous extraction of morphine and codeine from urine samples for quantification with LC‐MS. The miniaturized silica monolith with hydroxyl groups present on the largely exposed surface area function as a weak cation exchanger for solid phase extraction (SPE). The miniaturized silica cartridge in 1 cm diameter and 0.5 cm length was housed in a 2‐ml syringe fixed over a SPE vacuum manifold for extraction. The cleaning effectiveness of the cartridge was confirmed by osmometer, atomic absorption spectrometer, LC‐MS and GC‐TOFMS. The drugs were efficiently extracted from urine samples with recoveries ranging from 86% to 114%. The extracted analytes, after concentration and reconstitution, were quantified using LC‐MS/MS. The limits of detection for morphine and codeine were 2 ng/ml and 1 ng/mL, respectively. The relative standard deviations of measurements ranged from 3% to 12%. The monolithic sorbent offered good linearity with correlation coefficients > 0.99, over a concentration range of 50–500 ng/ml. The silica monolithic cartridge was found to be more robust than the particle‐based packed sorbent and also the commercial cartridge with regards to its recyclability and repeated usage with minimal loss in efficiency. Our study demonstrated the efficiency of the miniaturized silica monolith for removal of matrix ions and extraction of drugs of abuse in urinary screening. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

6.
An automated at-line SPE–GC–MS system for the determination of micropollutants in aqueous samples, which is based on the PrepStation and uses large-volume on-column injections, has been redesigned. A cartridge made from stainless steel and polychlorotrifluoroethylene and a 2-needle system was constructed which allow the determination of micropollutants at the low ng/L level without interferences from impurities extracted from the septa of the vials or the commercial cartridges. No time-consuming pre-cleaning of the cartridges or septa is required. The SPE sample extract (300 μL) is transferred from the sample preparation module to the autosampler of the GC–MS and 50 or 100 μL are injected. The analytical characteristics of the integrated procedure such as analyte recovery (typically 80–105%) and repeatability (RSDs, 2–9%), were satisfactory. Several micropollutants were detected in (unfiltered) river water at the 0.2–400 ng/L level using full-scan MS acquisition. The system proved to be robust during the analysis of more than 100 tap and river water samples.  相似文献   

7.
A sensitive and rapid method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) combined with rapid solid-phase extraction (SPE) has been developed and validated for the quantitative determination of enalapril and its active metabolite enalaprilat in human plasma. After addition of internal standard to human plasma, samples were extracted by 96-well SPE cartridge. The extracts were analyzed by HPLC with the detection of the analyte in the multiple reaction monitoring (MRM) mode. This method for the simultaneous determination of enalapril and enalaprilat was accurate and reproducible, with respective limits of quantitation of 0.2 and 1.0 ng/mL in plasma. The standard calibration curves for both enalapril and enalaprilat were linear (r(2) = 0.9978 and 0.9998) over the concentration ranges 0.2-200 and 1.0-100 ng/mL in human plasma, respectively. The intra- and inter-day precision over the concentration range for enalapril and enalaprilat were lower than 13.3 and 15.4% (relative standard deviation, %RSD), and accuracy was between 89.2-105.0 and 91.9-104.7%, respectively.  相似文献   

8.
A rapid, specific, and sensitive procedure for determining residues of 4 widely used tetracycline antibiotics and 3 of their 4-epimers in cheese is presented. The method is based on the matrix solid-phase dispersion (MSPD) technique followed by liquid chromatography/tandem mass spectrometry (LC/MS/MS). After dispersing samples of mozzarella, asiago, parmigiano, gruyere, emmenthal, and camembert on sand, target compounds were eluted from the MSPD column by passing through it 6 mL water heated at 70 degrees C. After acidification and filtration, 200 microL of the aqueous extract was directly injected into the LC column. For analyte identification and quantification, MS data acquisition was performed in the multireaction monitoring mode, selecting 2 precursor ion-to-product ion transitions for each target compound. Hot water appeared to be an efficient extractant, because absolute recoveries were no lower than 78%. Using demeclocycline as a surrogate analyte, recoveries of analyte added to the 6 types of cheeses at the 30 ng/g level were 96-117%, with relative standard deviation (RSD) not higher than 9%. Statistical analysis of the mean recovery data showed that the extraction efficiency was not dependent on the type of cheese analyzed. This result indicates that this method could be applied to other cheese types not considered here. At the lowest concentration considered, i.e., 10 ng/g, the accuracy of the method ranged between 90 and 107%, with RSDs not larger than 12%. Based on a signal-to-noise ratio of 10, limits of quantitation were estimated to be 1-2 ng/g.  相似文献   

9.
The high surface area monolith with reactive hydroxyl group on its surface enables it to function as a miniature solid‐phase extraction (SPE) cartridge in size of 1 cm in diameter and 0.5 cm in length. The prepared silica monolith was characterized by Brunauer–Emmett–Teller method, scanning electron microscopy, X‐ray diffraction and Fourier transform infrared (FTIR) spectroscopy. Ketamine was selected as model analyte to validate the extraction efficiency of the prepared cartridge. The extracted ketamine from urine sample was quantitated by liquid chromatography tandem mass spectrometry (LC‐MS/MS) using positive electrospray ionization. The limit of detection and quantification for ketamine was found to be 0.5 and 1.6 ng/mL, respectively. The analysis exhibited linearity in the range of 10–500 ng/mL with coefficient of correlation >0.99. The recovery was found to be in the range of 89–107% with relative standard deviation (RSD) less than 10%. The prepared cartridge was found robust in extracting ketamine efficiently and repeatedly without any significant deterioration in its performance. Moreover, the batch‐to‐batch variations in the performance of the prepared cartridges in terms of % ion suppression of the extracts and recoveries of samples were small, suggesting the consistency in the properties of the monolith.  相似文献   

10.
A high‐throughput LC–MS/MS bioanalytical method was developed and validated for the determination of hydrocortisone in mouse serum via supported liquid extraction (SLE) in a 96‐well plate format. Although sample extracts from SLE result in similar matrix effects compared with conventional liquid–liquid extraction (LLE), greater analyte extraction recovery and much higher analysis throughput for the quantitative analysis of hydrocortisone in mouse serum were obtained. The current LC‐MS/MS method was validated for a concentration range of 2.00–2000 ng/mL for hydrocortisone using a 0.100 mL volume of mouse serum. The intra‐ and inter‐day precision and accuracy of the quality control samples at low, medium and high concentration levels showed ≤12.9% CV and ?3.4–6.2% bias for the analyte in mouse serum. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
Domoic acid (DA) is a neurotoxic amino acid that is responsible for the human toxic syndrome, amnesic shellfish poisoning (ASP). A new rapid, sensitive liquid chromatographic (LC) method has been developed for the determination of DA in various marine samples. DA in marine biological materials was derivatised with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) and analysed using isocratic reversed-phase LC with fluorimetric detection. The calibration, based on standard DA solutions, was linear in the range 0.04-2 microg/ml (r2=0.998) and the detection limit (3:1, signal/noise) was better than 1 ng/ml. Using the certified reference material (MUS-1B), recoveries of DA from shellfish tissue were >95% (n=5). When a strong anion exchange SPE cartridge was used for sample clean-up the detection limit was 6 ng DA/g mussel tissue. Good reproducibility was achieved with RSD values ranging from 3% for 8 microg DA/g (n=5), to 5% for 0.04 microg DA/g (n=5). This new method was successfully applied to the determination of DA in naturally contaminated shellfish and in marine phytoplankton cultures of Pseudonitzschia sp.  相似文献   

12.
A method using an on-line solid phase extraction (SPE) and liquid chromatography with electrospray-tandem mass spectrometry (LC-ES-MS/MS) for the determination of flunitrazepam (FM2) and 7-aminoflunitrazepam (7-aminoFM2) in urine was developed. A mixed mode Oasis HLB SPE cartridge column was utilized for on-line extraction. A reversed phase C18 LC column was employed for LC separation and MS/MS was used for detection. Sample extraction, clean-up and elution were performed automatically and controlled by a six-port valve. Recoveries ranging from 94.8 to 101.3% were measured. For both 7-aminoFM2 and FM2, dual linear ranges were determined from 20 to 200 and 200-2000 ng/ml, respectively. The detection limit for each analyte based on a signal-to-noise ratio of 3 ranged from 1 to 3 ng/ml. The intra-day and inter-day precision showed coefficients of variance (CV) ranging from 4.6 to 8.5 and 2.6-9.2%, respectively. The applicability of this newly developed method was examined by analyzing several urine samples.  相似文献   

13.
A liquid chromatographic/turbo ionspray tandem mass spectrometric (LC/MS/MS) method was developed and validated for the determination of L-753,037, a potent endothelin receptor antagonist currently under development for the treatment of cardiovascular diseases, in human plasma. L-753,037 is extracted from 0.5 ml of human plasma using liquid-liquid extraction and analyzed by LC/MS/MS with a turbo ionspray interface. Method validation results showed that this method is very sensitive, reliable, selective and reproducible. L-753,048, an ethoxy analogue of L-753,037, was used as the internal standard. The method has a lower limit of quantitation (LOQ) of 50 pg ml(-1) with a linear calibration range of 0.05-50 ng ml(-1). The intra-day precision and accuracy (n = 5) were measured to be below 10% relative standard deviation (RSD) and between 97.4 and 102.8% of the nominal values, respectively, for all calibration standard concentrations within the calibration curve range. The inter-day precision and accuracy (n = 3 days, 5 replicates per day) were measured to be below 6.5% RSD and between 99.3 and 102.0% of the nominal values, respectively, for all quality control concentrations. The extraction recovery was determined to be approximately 99% on average. The analyte was found to be stable in plasma through three freeze-thaw cycles, for at least 4 h at ambient temperature and for up to 40 days under -20 degrees C freezer storage conditions. The analyte was also shown to be stable for at least 24 h in the reconstitution solution at room temperature and for up to 3 days as a dried extract at 4 degrees C. Additional variations in plasma concentration of the analyte due to the use of different sources of plasma were also evaluated.  相似文献   

14.
A generic sample preparation method for the determination of acrylamide in foods was developed. The method entails extraction with methanol, purification with Carrez I and II solutions, evaporation and solvent change to water, and cleanup with Oasis HLB solid-phase extraction (SPE) cartridge. The final extract was analyzed by liquid chromatography-mass spectrometry (LC-MS) for quantitation. The chromatographic separation was performed on ODS-3 column using the isocratic mixture of 0.01 mM acetic acid in 0.2% aqueous solution of formic acid at a flow rate of 0.6 ml/min at 25 degrees C. The recoveries of acrylamide from potato chips, biscuits and coffee ranged between 92.8 and 101.5% with relative standard deviations of 4.1% or less. The limit of detection (LOD) and the limit of quantitation (LOQ) were 2 ng/g and 6 ng/g in the basis of signal to noise ratios of 3:1 and 9:1, respectively.  相似文献   

15.
建立了液相色谱–三重四极杆串联质谱测定水果及其制品中氯吡脲的方法。样品经乙腈提取,氨基固相萃取小柱净化后,用ZORBAX Extend-C18柱(150 mm×2.1 mm,5μm)分离,以甲醇–水为流动相等度洗脱,采用多反应监测正离子模式检测,外标法定量。氯吡脲的质量浓度在4.0~200.0 ng/m L范围内线性良好,相关系数大于0.999,在5.0,10.0,20.0μg/kg 3个添加水平下,氯吡脲的平均加标回收率为86%~92%,测定结果的相对标准偏差为5.3%~7.6%(n=5),方法定量下限为2.0μg/kg。方法灵敏度高,操作简便,定量准确,可满足梨、柑桔、黄桃等水果及其罐头制品中氯吡脲残留的检测与确证需要。  相似文献   

16.
The first liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of levetiracetam, an antiepileptic drug, in human plasma is described. The plasma filtrate obtained after solid-phase extraction (SPE), using a polymer-based, hydrophilic-lipophilic balanced (HLB) cartridge, was submitted directly to a short column LC/MS/MS assay. There was no significant matrix effect on the analysis. For validation of the method, the recovery of the free analytes was compared to that from an optimized extraction method, and the analyte stability was examined under conditions mimicking sample storage, handling, and analytical procedures. The extraction procedure yielded extremely clean extracts with a recovery of 79.95% and 89.02% for levetiracetam and the internal standard (IS), respectively. The intra-assay and inter-assay precision for the samples at the lower limit of quantitation (LLOQ) were 6.33 and 6.82%, respectively. The calibration curves were linear for the dynamic range of 0.5 to 50 microg/mL with a correlation coefficient r >/= 0.9971. The intra-assay accuracy at LLOQ, LQC, MQC, and HQC levels ranged from 81.60 to 95.40, 93.00 to 103.47, 95.97 to 104.09, and 91.15 to 95.18%, respectively, while the inter-assay accuracy at LLOQ, LQC, MQC and HQC levels varied from 80.20 to 95.40, 88.53 to 107.53, 95.97 to 108.45, and 91.15 to 112.70%, respectively. The method is rugged and fast with a total instrumental run time of 2 min. The method was successfully applied for bioequivalence studies in human subject samples after oral administration of 1000 mg immediate release (IR) formulations.  相似文献   

17.
Atenolol, nadolol, metoprolol, bisoprolol and betaxolol were simultaneously determined in groundwater samples by large‐volume injection coupled‐column reversed‐phase liquid chromatography with fluorescence detection (LVI‐LC‐LC‐FD) and liquid chromatography‐time‐of‐flight mass spectrometry (LC‐TOF‐MS). The LVI‐LC‐LC‐FD method combines analyte isolation, preconcentration and determination into a single step. Significant reductions in costs for sample pre‐treatment (solvent and solid phases for clean up) and method development times are also achieved. Using LC‐TOF‐MS, accurate mass measurements within 3 ppm error were obtained for all of the β‐blockers studied. Empirical formula information can be obtained by this method, allowing the unequivocal identification of the target compounds in the samples. To increase the sensitivity, a solid‐phase extraction step with Oasis MCX cartridge was carried out yielding recoveries of 79–114% (n=5) with RSD 2–7% for the LC‐TOF‐MS method. SPE gives a high purification of β‐blockers compared with the existing methods. A 100% methanol wash was allowed for these compounds with no loss of analytes. Limit of quantification was 1–7 ng/L for LVI‐LC‐LC‐FD and 0.25–5 ng/L for LC‐TOF‐MS. As a result of selective extraction and effective removal of coextractives, no matrix effect was observed in LVI‐LC‐LC‐FD and LC‐TOF‐MS analyses. The methods were applied to detect and quantify β‐blockers in groundwater samples of Almería (Spain).  相似文献   

18.
A novel liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method was developed for the trace residue determination of chloramphenicol (CAP) in bee pollen. CAP was extracted from bee pollen with a mixture of methanol and 1% metaphosphoric acid solution, followed by a 2-stage solid-phase extraction enrichment and cleanup. The first stage involved a polymeric cartridge, and the second stage involved an alumina neutral cartridge. The LC separation was performed on a C18 column with 10 mM ammonium formate-acetonitrile (7 + 3) as the mobile phase and MS detection with negative-ion electrospray ionization. CAP-d5 was used as the internal standard. The method was validated according to Commission Decision 2002/657/EC. The calibration curves were linear between 0.1 and 5.0 ng/mL, and overall recoveries ranged from 98 to 113%. Decision limits (CCalpha) ranged from 0.05 to 0.07 microg/kg, and detection capabilities (CCbeta) ranged from 0.08 to 0.12 microg/kg. The developed method was applied to 11 samples.  相似文献   

19.
A simple and rapid method using reversed-phase liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the simultaneous determination of the urinary metabolites of benzene, toluene, xylene and styrene in human urine specimens and standard solutions is described. A hybrid quadrupole/time-of-flight (QqTOF) mass spectrometer was compared for the determination of metabolite of aromatic solvents in urine samples. The metabolites selected were: trans,trans-muconic acid, hippuric acid, o-, m- and p-methylhippuric acid and phenylglyoxylic acid. The compounds were well separated from each other on narrow-bore 1-mm i.d. reversed-phase LC C-18 columns. Average recoveries for loading 100 microL of urine samples varied from 88-110% and the quantification limits were less than 30 ng/mL for each analyte (3 ng/mL for trans,trans-muconic acid). The qualitative information obtained (mass accuracy, resolution and full-scan spectra) with the QqTOF mass spectrometer allows a secure identification of analytes in biological matrices.  相似文献   

20.
The behaviour of 5-methyl-2'-deoxycytidine (m(5)dCyd, claimed to be a potential marker for leukaemia) during the electrospray process was studied. In particular, considerations concerning the effect of solution chemistry (e.g. analyte concentration, pH, etc.) on electrospray ionization mass spectra were drawn. Furthermore, a procedure using liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) for the determination of urinary m(5)dCyd is described. The method is simple, sensitive and highly specific. The pre-treatment procedure gave an average recovery of 79% (relative standard deviation (RSD) of 3%). Method performance was evaluated on spiked urine samples covering the concentration range from 50 ng/mL to 10 microgram/mL, the same as that of an existing inhibition ELISA method. Contrary to findings based on this immunoassay technique, urinary m(5)dCyd in healthy individuals was not detectable and did not increase in the presence of the malignant disease.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏