首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The development of a faradic impedimetric immunosensor based on electropolymerized polytyramine (Ptyr) films for the detection of S. typhimurium in milk is described for the first time. Polyclonal anti-Salmonella was cross-linked, in the presence of glutaraldehyde vapors, on Ptyr-modified gold electrodes. The dielectric behaviour of Ptyr films was evaluated with capacitance measurements, while their stability in neutral aqueous solutions was examined with impedimetric measurements. The effect of the concentration of tyramine in the forming solution on both the sensitivity and the dynamic range of the resulted immunosensors was also investigated. The alteration of the interfacial features of the electrodes due to different modification or recognition steps, was measured by faradic electrochemical impedance spectroscopy in the presence of a hexacyanoferrate(II)/(III) redox couple. At samples containing a low initial concentration of 10 cfu mL−1S. typhimurium, that actually defines the LOD of the immunosensors, signal changes of 33% and 88% were achieved after 3 and 10 h incubation, respectively. To achieve the working simplicity expected by a biosensor, immunoreaction was performed directly in cultures. This resulted in the elimination of various centrifugation and washing steps, which are used for the isolation of bacteria cells from the culture, thus making the proposed immunosensors promising candidates for on-site applications. Finally, the proposed immunosensors were successfully used for the detection of S. typhimurium in experimentally inoculated milk samples.  相似文献   

2.
菊酯类农药广谱型免疫层析试纸条的研究及应用   总被引:3,自引:0,他引:3  
建立了菊酯类农药广谱型免疫层析检测方法,可同时检测水果、蔬菜中12种甲氰菊酯、溴氰菊酯、氯氰菊酯、三氟氯氰菊酯农药残留。以粒径20 nm的胶体金标记羊抗小鼠IgG抗体于金标垫上,分别固定包被原(检测线,T线)、兔抗山羊 IgG 抗体(质控线, C 线)于硝酸纤维素膜( NC 膜)上,与吸水垫及聚氯乙烯( PVC)底板组合成层析试纸条。10 g样品经乙腈提取,PBS稀释4倍,取100μL与菊酯类农药的单克隆抗体混合后,直接用于试纸条检测。结果表明,试纸条对甲氰菊酯、溴氰菊酯、氯氰菊酯、三氟氯氰菊酯农药的裸眼观察检测灵敏度为0.5,5.0,5.0和5.0μg/mL,检测时长为8~10 min,采用QuEChERS方法,方法检测灵敏度可提高16倍。对蔬菜和水果的方法验证表明,除辣椒基质干扰呈假阳性外,其它样本的检测结果均与GC方法结果一致。试纸条采用金标羊抗小鼠IgG二抗的方法,使检测结果的重现性更好、更稳定,且抗基质干扰能力强,为菊酯类农药的累积毒性检测提供了新方法。  相似文献   

3.
《Electrophoresis》2017,38(3-4):501-506
With the recent worldwide changes in the legalization of marijuana, there is a significant need for rapid, roadside screening test for driving under the influence of drugs. A robust, sensitive, lateral flow assay has been developed to detect recent use via oral‐fluid testing for Δ9‐tetrahydrocannabinol (THC). This proof‐of‐concept assay uses a fluorescent‐based immunoassay detection of polymeric beads, conjugated to antibodies against native THC. The fluorescent technique allows for significantly lower limits of detection and higher precision determination of recent marijuana use without the use of urine or blood sampling—thus allowing for roadside identification. Detection levels of 0.01 ng/mL were distinguished from background and the lower limit of quantification was determined to approach 1 ng/mL.  相似文献   

4.
In recent years extensive numbers of molecular diagnostic methods have been developed to meet the need of point-of-care devices. Efforts have been made towards producing rapid, simple and inexpensive DNA tests, especially in the diagnostics field. We report on the development of a label-based lateral flow dipstick for the rapid and simple detection of multiplex loop-mediated isothermal amplification (m-LAMP) amplicons. A label-based m-LAMP lateral flow dipstick assay was developed for the simultaneous detection of target DNA template and a LAMP internal control. This biosensor operates through a label based system, in which probe-hybridization and the additional incubation step are eliminated. We demonstrated this m-LAMP assay by detecting pathogenic Leptospira, which causes the re-emerging disease Leptospirosis. The lateral flow dipstick was developed to detect of three targets, the LAMP target amplicon, the LAMP internal control amplicon and a chromatography control. Three lines appeared on the dipstick, indicating positive results for all representative pathogenic Leptospira species, whereas two lines appeared, indicating negative results, for other bacterial species. The specificity of this biosensor assay was 100% when it was tested with 13 representative pathogenic Leptospira species, 2 intermediate Leptospira species, 1 non-pathogenic Leptospira species and 28 other bacteria species. This study found that this DNA biosensor was able to detect DNA at concentrations as low as 3.95 × 10−1 genomic equivalent ml−1. An integrated m-LAMP and label-based lateral flow dipstick was successfully developed, promising simple and rapid visual detection in clinical diagnostics and serving as a point-of-care device.  相似文献   

5.
A rapid method for detection of Salmonella typhimurium contamination in packaged alfalfa sprouts using solid phase microextraction/gas chromatography/mass spectrometry (SPME/GC/MS) integrated with chemometrics was investigated. Alfalfa sprouts were inoculated with S. typhimurium, packed into commercial LDPE bags and stored at 10 + 2 °C for 0, 1, 2 and 3 days. Uninoculated sprouts were used as control samples. A SPME device was used to collect the volatiles from the headspace above the samples and the volatiles were identified using GC/MS. Chemometric techniques including linear discriminant analysis (LDA) and artificial neural network (ANN) were used as data processing tools. Numbers of Salmonella were followed using a colony counting method. From LDA, it was able to differentiate control samples from sprouts contaminated with S. typhimurium. The potential to predict the number of contaminated S. typhimurium from the SPME/GC/MS data was investigated using multilayer perceptron (MLP) neural network with back propagation training. The MLP comprised an input layer, one hidden layer, and an output layer, with a hyperbolic tangent sigmoidal transfer function in the hidden layer and a linear transfer function in the output layer. The MLP neural network with a back propagation algorithm could predict number of S. typhimurium in unknown samples using the volatile fingerprints. Good prediction was found as measured by a regression coefficient (R2 = 0.99) between actual and predicted data.  相似文献   

6.
The new method presented in this article achieved the goal of capturing Salmonella typhimurium via immunoreaction and rapid in situ detection of the CdSe/ZnS quantum dots (QDs) labeled S. typhimurium by self-assembly light-emitting diode-induced fluorescence detection (LIF) microsystem on a specially designed multichannel microfluidic chip. CdSe/ZnS QDs were used as fluorescent markers improving detection sensitivity. The microfluidic chip developed in this study was composed of 12 sample channels, 3 mixing zones, and 6 immune reaction zones, which also acted as fluorescence detection zones. QDs–IgG–primary antibody complexes were generated by mixing CdSe/ZnS QDs conjugated secondary antibody (QDs–IgG) and S. typhimurium antibody (primary antibody) in mixing zones. Then, the complexes went into immune reaction zones to label previously captured S. typhimurium in the sandwich mode. The capture rate of S. typhimurium in each detection zone was up to 70%. The enriched QDs-labeled S. typhimurium was detected using a self-assembly LIF microsystem. A good linear relationship was obtained in the range from 3.7 × 10 to 3.7 × 105 cfu mL−1 using the equation I = 0.1739 log (C) − 0.1889 with R2 = 0.9907, and the detection limit was down to 37 cfu mL−1. The proposed method of online immunolabeling with QDs for in situ fluorescence detection on the designed multichannel microfluidic chip had been successfully used to detect S. typhimurium in pork sample, and it has shown potential advantages in practice.  相似文献   

7.
Simple, rapid and highly sensitive assays, possibly allowing on-site analysis, are required in the security and forensic fields or to obtain early signs of environmental pollution. Several bioanalytical methods and biosensors based on portable devices have been developed for this purpose. Among them, Lateral Flow ImmunoAssays (LFIAs) offer the advantages of rapidity and ease of use and, thanks to the high specificity of antigen–antibody binding, allow greatly simplifying and reducing sample pre-analytical treatments. However, LFIAs usually employ colloidal gold or latex beads as labels and they rely on the formation of colored bands visible by the naked eye. With this assay format, only qualitative or semi-quantitative information can be obtained and low sensitivity is achieved. Recently, the use of enzyme-catalyzed chemiluminescence detection in LFIA has been proposed to overcome these problems. In this work, we describe the development of a quantitative CL-LFIA assay for the detection of 2,4,6-trinitrotoluene (TNT) in real samples. Thanks to the use of a portable imaging device for CL signal measurement based on a thermoelectrically cooled CCD camera, the analysis could be performed directly on-field. A limit of detection of 0.2 μg mL−1 TNT was obtained, which is five times lower than that obtained with a previously described colloidal gold-based LFIA developed employing the same immunoreagents. The dynamic range of the assay extended up to 5 μg mL−1 TNT and recoveries ranging from 97% to 111% were obtained in the analysis of real samples (post blast residues obtained from controlled explosion).  相似文献   

8.
建立了定量检测氟苯尼考的胶体金免疫层析方法.对胶体金标记抗体时溶液pH和抗体浓度、金标抗体用量、检测线上抗原浓度以及检测时间进行了优化.采用胶体金试纸条读取仪测定试纸条检测线和质控线的信号强度,以标准品的浓度为横坐标,阳性样本和阴性样本的检测线/质控线的信号比值(Bx/B0)为纵坐标建立标准曲线.结果表明,胶体金免疫层析试纸定量检测氟苯尼考的线性范围为0.1~1.5 ng/mL,检出限为0.08 ng/mL,检测时间为15 min.本方法具有简便、快速和可定量等特点,适于大批量样品的现场筛查.  相似文献   

9.
We reported here for the first time on the use of cotton thread combined with novel gold nanoparticle trimer reporter probe for low-cost, sensitive and rapid detection of a lung cancer related biomarker, human ferritin. A model system comprising ferritin as an analyte and a pair of monoclonal antibodies was used to demonstrate the proof-of-concept on the dry-reagent natural cotton thread immunoassay device. Results indicated that the using of novel gold nanoparticle trimer reporter probe greatly improved the sensitivity comparing with traditional gold nanoparticle reporter probe on the cotton thread immunoassay device. The assay avoids multiple incubation and washing steps performed in most conventional protein analyses. Although qualitative tests are realized by observing the color change of the test zone, quantitative data are obtained by recording the optical responses of the test zone with a commercial scanner and corresponding analysis software. Under optimal conditions, the cotton thread immunoassay device was capable of measuring 10 ng/mL human ferritin under room temperature which is sensitive enough for clinical diagnosis. Moreover, the sample solution employed in the assays is just 8 μL, which is much less than traditional lateral flow strip based biosensors.  相似文献   

10.
In this study, a natural cotton thread immunoassay device combined with gold nanorod (GNR) reporter probe is developed for the rapid, sensitive and quantitative electrochemical determination of human ferritin, a lung cancer related biomarker. Human ferritin as an analyte and a pair of monoclonal antibodies are used to demonstrate the proof-of-concept on the cotton thread immunoassay device. An enhancement of the sensitivity is achieved by using gold nanorod as an electroactive report probe compared with a traditional gold nanoparticle (GNP) report probe. The device was capable of measuring 1.58 ng/mL ferritin in 30 min by anodic stripping voltammetry (ASV) testing, which meet the requirement for clinical diagnosis.  相似文献   

11.
A bioanalytical detection method for specific detection of viable human pathogenic Cryptosporidium species, C. parvum, C. hominis, and C. meleagridis is described. Oocysts were isolated from water samples via immunomagnetic separation, and mRNA was extracted with oligo-dT magnetic beads, amplified using nucleic acid sequence-based amplification (NASBA), and then detected in a nucleic acid hybridization lateral flow assay. The amplified target sequence employed was hsp70 mRNA, production of which is stimulated via a brief heat shock. The described method was capable of detecting one oocyst in 10 μL using flow-cytometer-counted samples. Only viable oocysts were detected, as confirmed using 4′,6-diamidino-2-phenylindole and propidium iodide (DAPI/PI) staining. The detection system was challenged by detecting oocysts in the presence of large numbers of common waterborne microorganisms and packed pellet material filtered from environmental water samples. When the method was compared with EPA Method 1622 for C. parvum detection, highly comparable results were obtained. Since the described detection system yields unambiguous results within 4.5 h, it is an ideal method for monitoring the safety of drinking water.  相似文献   

12.
A sensitive, specific method for the collection and detection of pathogenic bacteria was demonstrated using quantum dots (QDs) as a fluorescence marker coupled with aptamers as the molecular recognition element by flow cytometry. The aptamer sequences were selected using a bacterium-based SELEX strategy in our laboratory for Vibrio parahaemolyticus and Salmonella typhimurium that, when applied in this method, allows for the specific recognition of the bacteria from complex mixtures including shrimp samples. Aptamer-modified QDs (QD-apt) were employed to selectively capture and simultaneously detect the target bacteria with high sensitivity using the fluorescence of the labeled QDs. The signal intensity is amplified due to the high photostability of QDs nanoparticles, resulting in improved sensitivity over methods using individual dye-labeled probes. This proposed method is promising for the sensitive detection of other pathogenic bacteria in food stuff if suitable aptamers are chosen. The method may also provide another potential platform for the application of aptamer-conjugated QDs in flow cytometry.  相似文献   

13.
Rapid detection and enumeration of pathogens is essential for monitoring contamination and spoilage of food products to ensure improved quality control management. Functionalized polymeric magnetic nanoconstructs (FPMNCs) were developed as an effective immunomagnetic separator and sensing platform for the selective capturing of Salmonella typhimurium. Novel FPMNCs were prepared in three stages involving synthesis of iron oxide (IO) dispersion, capping with sodium oleate and encapsulation of preformed IO nanoparticles by in-situ free radical emulsion polymerization of styrene (St), methyl methacrylate (MMA) and acetoacetoxy ethylmethacrylate (AAEM). PMMA improves the stability of FPMNCs by bridging extremely hydrophobic PS and hydrophilic PAAEM. Core-shell morphology of hydrophobic core of IO, PS & PMMA and hydrophilic shell of PAAEM was demonstrated by SEM, TEM and FTIR studies. FPMNCs with surface functionalized acetoacetoxy groups were covalently attached with polyclonal antibodies against Salmonella common structural antigen (CSA-1-Ab) without using any linker and catalyst. Colorimetric readout signal was acquired using CSA-1-Ab-HRP as secondary antibody after formation of sandwich immunocomplex with bacteria where the optical density of the samples were recorded using ELISA plate reader at 450 nm. The developed immunoassay was specific and selective which captures only targeted S. typhimurium with a detection limit of 10 cells/mL lower than infectious dose of salmonellosis infection. Minimal interference of food matrix with high signal to noise ratio was shown by various food samples. In addition, the performance of developed FPMNC based immunoassay was superior to commercially available immunomagnetic microbeads demonstrating undisputed advantage for capturing and detecting specific bacteria without any pre-enrichment of sample.  相似文献   

14.
A QDs-based immune fl uorescence test strips was built up for carcino-embryonic antigen detection to realize cancers POCT diagnostic, with a sensitivity of 0.72 ng/mL in 25 min.  相似文献   

15.
Lateral flow devices (LFDs) are qualitative immunochromatographic tests for the rapid and specific detection of target analytes. We investigated commercially available LFDs for their ability to detect potentially allergenic peanut and hazelnut in raw cookie dough and chocolate, two important food matrices in the industrial production of cookies. Each three commercial LFDs for the detection of hazelnut and peanut were performed according to the manufacturers’ instructions. All LFDs had comparably satisfactory specificity that was investigated with a variety of characteristic foods and food ingredients used in the production of cookies. In concordance with hazelnut-specific enzyme-linked immunosorbent assays (ELISAs), walnut was the most cross-reactive food for hazelnut-specific LFD. The sensitivity was verified in raw cookie doughs and chocolates that were either spiked with peanut or hazelnut between 1 and 25 mg/kg, respectively. Two hazelnut-specific LFDs detected hazelnut at a level of 3.5 mg/kg in both matrices, whereas the third LFD detected hazelnut at a level of 3.9 mg/kg in dough and 12.5 mg/kg in chocolate. Two peanut-specific LFDs detected peanut at a level of 1 mg/kg in both matrices. The third LFD detected peanut at a level of 14.2 mg/kg in chocolate and 4 mg/kg in dough. In conclusion, specific and sensitive LFD were identified for each hazelnut and peanut, having a level of sensitivity that is comparable to commercial ELISA for the investigated matrices. Such sensitive, specific, and rapid tests are useful analytical tools for allergen screening and sanitation in the industrial manufacture of foods.  相似文献   

16.
We summarized the principle of LFAs, three main elements for the LFAs (recognition molecule, signal transduction element, the targets) and different optimal experimental conditions in the recent LFA-related studies to give detailed overview of the LFA development.  相似文献   

17.
A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β2-agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β2-agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL−1, with the detection limits of 0.20 and 0.040 ng mL−1 (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β2-agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety.  相似文献   

18.
A colloidal gold conjugated anti-baicalin monoclonal antibody (anti-BA MAb) was prepared and used in an immunochromatographic assay (ICA) for BA in Scutellariae Radix and Kampo medicines. This competitive ICA uses an anti-BA MAb which shows a high specificity for BA and baicalein. Its advantages include a short assay time (15 min), no dependence on any instrumental systems, and it can detect BA in plant materials and Kampo medicines. The limit of detection for the ICA was found to be around 0.6 μg mL−1of baicalin. Moreover, the usefulness of the combination of indirect competitive ELISA and the ICA using anti-BA MAb as a quality control method was confirmed for analysis of BA in Scutellariae Radix and Kampo medicines with a sufficient sensitivity (200 ng mL−1 to 2 μg mL−1), obtainable in an easy and timely manner.  相似文献   

19.
A MEMS‐based impedance biosensor was designed, fabricated, and tested to effectively detect the presence of bacterial cells including E. coli O157:H7 and Salmonella typhimurium in raw chicken products using detection region made of multiple interdigitated electrode arrays. A positive dielectrophoresis based focusing electrode was used in order to focus and concentrate the bacterial cells at the centerline of the fluidic microchannel and direct them toward the detection microchannel. The biosensor was fabricated using surface micromachining technology on a glass substrate. The results demonstrate that the device can detect Salmonella with concentrations as low as 10 cells/mL in less than 1 h. The device sensitivity was improved by the addition of the focusing electrodes, which increased the signal response by a factor between 6 and 18 times higher than without the use of the focusing electrodes. The biosensor is selective and can detect other types of pathogen by changing the type of the antibody immobilized on the detection electrodes. The device was able to differentiate live from dead bacteria.  相似文献   

20.
Poly(dimethylsiloxane) microchip capillary electrophoresis with amperometric detection has been used for rapid separation and determination of acetaminophen and its hydrolysate, i.e. p-aminophenol. A Pt ultramicroelectrode with a diameter of 10 m positioned at the outlet of the separation channel was used as a working electrode for amperometric detection. Factors influencing separation and detection were investigated and optimized. Results show that acetaminophen and p-aminophenol can be well separated within 35 s with RSD<1% for migration time and <7% for detection current for both analytes. Detection limits for both analytes are estimated to be 5.0 mol L–1 (approximately 0.1 fmol) at S/N=3. This method has been successfully applied to the detection of traces of p-aminophenol in paracetamol tablets.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号