首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Benzofurazan derivatization reagents, 4‐[2‐(N,N‐dimethylamino)ethylaminosulfonyl]‐7‐(2‐aminopentylamino)‐2,1,3‐benzoxadiazole (DAABD‐AP) and 4‐[2‐(N,N‐dimethylamino) ethylaminosulfonyl]‐7‐(2‐aminobutylamino)‐2,1,3‐benzoxadiazole (DAABD‐AB), for short‐chain carboxylic acids in liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) were synthesized. These reagents reacted with short chain carboxylic acids in the presence of the condensation reagents at 60°C for 60 min. The generated derivatives were separated on the reversed‐phase column and detected by ESI‐MS/MS with the detection limits of 0.1–0.12 pmol on column. Upon collision‐induced dissociation, a single and intense product ion at m/z 151 was observed. These results indicated that DAABD‐AP and DAABD‐AB are suitable as the derivatization reagents in LC/ESI‐MS/MS analysis. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

2.
The derivatization reagents for carboxylic acids, N‐(Pyridin‐3‐yl)hydrazinecarbothioamide, N‐[4‐(dimethylamino)phenyl]hydrazinecarbothioamide, 1‐(2‐aminoethyl)‐3‐(pyridin‐3‐yl)thiourea, 1‐(2‐aminoethyl)‐3‐[4‐(dimethylamino)phenyl]thiourea and 4‐(2‐aminoethyl)‐N‐phenylpiperazine‐1‐carbothioamide were synthesized. These reagents reacted with carboxylic acids at 60°C for 45 min in the presence of the condensation reagents. The generated derivatives were favorably separated on the reversed‐phase column and sensitively detected by electrospray ionization tandem mass spectrometry. These reagents enhanced the electrospray ionization response of the analyte and generated a particular product ion efficiently by collision‐induced dissociation, and thus they were suitable for MS/MS detection. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
The applicability of 3‐pyridyl isothiocyanate, p‐(dimethylamino)phenyl isothiocyanate and m‐nitrophenyl isothiocyanate as the derivatization reagents for amines in high‐performance liquid chromatography/electrospray ionization–tandem mass spectrometry (LC/ESI‐MS/MS) was examined. The generated derivatives of amines with these reagents were favorably separated on the reversed‐phase column and detected by ESI‐MS/MS. The C–N bond of the generated thiourea structure was efficiently cleaved by collision‐induced dissociation and gave the single and intense product ion. Among the three reagents, 3‐pyridyl isothiocyanate was the most suitable as the derivatization reagent with regard to the reactivity to amines and the detection sensitivity. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
We applied a new technique for quantitative linear range shift using in‐source collision‐induced dissociation (CID) to complex biological fluids to demonstrate its utility. The technique was used in a simultaneous quantitative determination method of 5‐fluorouracil (5‐FU), an anticancer drug for various solid tumors, and its metabolites in human plasma by liquid chromatography–electrospray ionization–tandem mass spectrometry (LC/ESI‐MS/MS). To control adverse effects after administration of 5‐FU, it is important to monitor the plasma concentration of 5‐FU and its metabolites; however, no simultaneous determination method has yet been reported because of vastly different physical and chemical properties of compounds. We developed a new analytical method for simultaneously determining 5‐FU and its metabolites in human plasma by LC/ESI‐MS/MS coupled with the technique for quantitative linear range shift using in‐source CID. Hydrophilic interaction liquid chromatography using a stationary phase with zwitterionic functional groups, phosphorylcholine, was suitable for separation of 5‐FU from its nucleoside and interfering endogenous materials. The addition of glycerin into acetonitrile‐rich eluent after LC separation improved the ESI‐MS response of high polar analytes. Based on the validation results, linear range shifts by in‐source CID is the reliable technique even with complex biological samples such as plasma. Copyright © 2016 John Wiley & Sons Ltd.  相似文献   

5.
This study reported a pH‐mediated stacking CE coupled with ESI MS/MS method to determine the phosphorylation sites of three synthetic phosphopeptides containing structural isomers. These phosphopeptides mimic the phosphopeptides (amino acid residues 12–25) derived from the trypsin‐digested products of human lamin A/C protein. The LODs were determined to be 118, 132 and 1240 fmol for SGAQASS19TpPL22SPTR, SGAQASS19TPL22SpPTR, and SGAQASS19TpPL22SpPTR, respectively. The established method was employed to analyze the phosphorylation sites of the trypsin‐digested products of glutathione S‐transferase‐lamin A/C (1–57) fusion protein that had been phosphorylated in vitro by cyclin‐dependent kinase 1. The results indicated that this method is feasible to specifically determine the phosphorylation site from phosphopeptide isomers in the trypsin‐digested products of a kinase‐catalyzed phosphoprotein, which should benefit the investigation of protein kinase‐mediated cellular signal transduction.  相似文献   

6.
In vivo metabolites of ketorolac (KTC) have been identified and characterized by using liquid chromatography positive ion electrospray ionization high resolution tandem mass spectrometry (LC/ESI‐HR‐MS/MS) in combination with online hydrogen/deuterium exchange (HDX) experiments. To identify in vivo metabolites, blood urine and feces samples were collected after oral administration of KTC to Sprague–Dawley rats. The samples were prepared using an optimized sample preparation approach involving protein precipitation and freeze liquid separation followed by solid‐phase extraction and then subjected to LC/HR‐MS/MS analysis. A total of 12 metabolites have been identified in urine samples including hydroxy and glucuronide metabolites, which are also observed in plasma samples. In feces, only O‐sulfate metabolite and unchanged KTC are observed. The structures of metabolites were elucidated using LC‐MS/MS and MSn experiments combined with accurate mass measurements. Online HDX experiments have been used to support the structural characterization of drug metabolites. The main phase I metabolites of KTC are hydroxylated and decarbonylated metabolites, which undergo subsequent phase II glucuronidation pathways. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
Methylation is an essential metabolic process for a number of critical reactions in the body. Methyl groups are involved in the healthy function of the body life processes, by conducting methylation process involving specific enzymes. In these processes, various amino acids are methylated, and the occurrence of methylated amino acids in nature is diverse. Nowadays, mass‐spectrometric‐based identification of small molecules as biomarkers for diseases is a growing research. Although all dimethyl amino acids are metabolically important molecules, mass spectral data are available only for a few of them in the literature. In this study, we report synthesis and characterization of all dimethyl amino acids, by electrospray ionization–tandem mass spectrometry (MS/MS) experiments on protonated molecules. The MS/MS spectra of all the studied dimethyl amino acids showed preliminary loss of H2O + CO to form corresponding immonium ions. The other product ions in the spectra are highly characteristic of the methyl groups on the nitrogen and side chain of the amino acids. The amino acids, which are isomeric and isobaric with the studied dimethyl amino acids, gave distinctive MS/MS spectra. The study also included MS/MS analysis of immonium ions of dimethyl amino acids that provide information on side chain structure, and it is further tested to determine the N‐terminal amino acid of the peptides. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
A direct injection liquid chromatography–electrospray ionization–tandem mass spectrometric method (LC‐ESI‐MS/MS) was developed and validated for the rapid and simple determination of 13 phenylalkylamine derivatives. Eight deuterium‐labeled compounds were prepared for use as internal standards (ISs) to quantify the analytes. Urine samples mixed with ISs were centrifuged, filtered through 0.22 µm filters and then injected directly into the LC‐ESI‐MS/MS system. The mobile phase was composed of 0.2% formic acid and 2 mM ammonium formate in distilled water and 0.2% formic acid and 2 mM ammonium formate in acetonitrile. The analytical column was a Capcell Pak MG‐II C18 (150 × 2.0 mm i.d., 5 µm, Shiseido). Separation and detection of the analytes were accomplished within 10 min. The linear ranges were 5–750 ng/mL (ephedrine and fenfluramine), 10–750 ng/mL (3,4‐methylenedioxyamphetamine, phendimetrazine, methamphetamine, 3,4‐methylenedioxyethylamphetamine and benzphetamine), 20–750 ng/mL (norephedrine, amphetamine, phentermine and ketamine) and 30–1000 ng/mL (3,4‐methylenedioxymethamphetamine and norketamine), with determination coefficients, R2, ≥ 0.9967. The intra‐day and inter‐day precisions were within 19.1%. The intra‐day and inter‐day accuracies ranged from ?16.0 to 18.7%. The lower limits of quantification for all the analytes were lower than 26.5 ng/mL. The applicability of the method was examined by analyzing urine samples from drug abusers (n = 30). Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
In this article, the effect of spray solvent on the analysis of selected lipids including fatty acids, fat‐soluble vitamins, triacylglycerols, steroids, phospholipids, and sphingolipids has been studied by two different ambient mass spectrometry (MS) methods, desorption electrospray ionization‐MS (DESI‐MS) and desorption atmospheric pressure photoionization‐MS (DAPPI‐MS). The ionization of the lipids with DESI and DAPPI was strongly dependent on the spray solvent. In most cases, the lipids were detected as protonated or deprotonated molecules; however, other ions were also formed, such as adduct ions (in DESI), [M‐H]+ ions (in DESI and DAPPI), radical ions (in DAPPI), and abundant oxidation products (in DESI and DAPPI). DAPPI provided efficient desorption and ionization for neutral and less polar as well as for ionic lipids but caused extensive fragmentation for larger and more labile compounds because of a thermal desorption process. DESI was more suitable for the analysis of the large and labile lipids, but the ionization efficiency for less polar lipids was poor. Both methods were successfully applied to the direct analysis of lipids from pharmaceutical and food products. Although DESI and DAPPI provide efficient analysis of lipids, the multiple and largely unpredictable ionization reactions may set challenges for routine lipid analysis with these methods. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

10.
Crizotinib is a small molecule inhibitor of anaplastic lymphoma kinase (ALK) and can be used to treat ALK‐positive nonsmall‐cell lung cancer. A rapid and simple high‐performance liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated for the quantification of crizotinib in rat plasma using a chemical synthetic compound buspirone as the internal standard (IS). The plasma samples were pretreated by a simple protein precipitation with methanol–acetonitrile (1:1, v/v). Chromatographic separation was successfully achieved on an Agilent Zorbax XDB C18 column (2.1 × 50 mm, 3.5 µm). The gradient elution system was composed of 0.1% formic acid aqueous solution and 0.1% formic acid in methanol solution. The flow rate was set at 0.50 mL/min. The multiple reaction monitoring was based on the transitions of m/z = 450.3 → 177.1 for crizotinib and 386.2 → 122.2 for buspirone (IS). The assay was successfully validated to demonstrate the selectivity, matrix effect, linearity, lower limit of quantification, accuracy, precision, recovery and stability according to the international guidelines. The lower limit of quantification was 1.00 ng/mL in 50 μL of rat plasma. This LC‐MS/MS assay was successfully applied to the quantification and pharmacokinetic study of crizotinib in rats after intravenous and oral administration of crizotinib. The oral absolute bioavailability of crizotinib in rats was 68.6 ± 9.63%. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
Drugs deposited in human teeth are well preserved; the spectrum of toxicological investigations may therefore be supplemented by an analysis method for drugs in teeth. A liquid chromatography–electrospray ionization tandem mass spectrometry assay for the detection and quantification of basic drugs of abuse in bovine dentin samples was developed and validated. The drugs and metabolites amphetamine, methamphetamine, methylenedioxymethylamphetamine, methylenedioxyethylamphetamine, codeine, morphine, cocaine and benzoylecgonine were extracted from 50 mg ground dentin powder by ultrasonication for 60 min in methanol 3 times. The extracts were analyzed on a triple‐quadrupole mass‐spectrometer in multiple reaction monitoring mode. The method was validated and proved to be accurate, precise, selective, specific and stable with good linearity within the calibration range and a lower limit of quantification of 10 to 20 pg/mg. To artificially load bovine dentin samples with drugs, the natural process of de‐ and remineralization in the oral cavity was mimicked by a pH‐cycling experiment. The artificially drug‐loaded dentin samples showed drug concentrations of 20 to 80 pg/mg. The method can be applied in further in vitro experiments as well as in post‐mortem cases, especially where limited sample tissue is available. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

12.
The fragmentation reactions of N‐monoalkyloxyphosphoryl amino acids (N‐MAP‐AAs) were studied by electrospray ionization tandem mass spectrometry (ESI‐MS). The sodiated cyclic acylphosphoramidates (CAPAs) were formed through a characteristic pentacoordinate phosphate participated rearrangement reaction in the positive‐ion ESI‐MS/MS and HR‐MS/MS of N‐MAP‐AAs, in which the fragmentation patterns were clearly different from those observed in the corresponding ESI‐MS/MS of N‐dialkyloxyphosphoryl amino acids/peptides and N‐phosphono amino acids. The formation of CAPAs depended on the chemical structures of N‐terminal phosphoryl groups, such as alkyloxy group, negative charge and alkali metal ion. A possible integrated rearrangement mechanism for both PN to PO phosphoryl group migration and formation of CAPAs was proposed. The fragmentation patterns of CAPAs as novel intermediates in gas phase were also investigated. In addition, it was found that the formation of α‐amino acid CAPAs was more favorable than β‐ or γ‐CAPAs in gas phase, which was consistent with previous solution‐phase experiments. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
Toosendanin (TSN) is a major triterpenoid existing in Melia toosendan, which has been used as a digestive tract parasiticide and insecticide but with serious hepatotoxicity. An ultra‐performance liquid chromatography–electrospray ionization–mass spectrometry method was developed for determination of TSN in rat plasma. Plasma samples were separated on Acquity UPLCTM BEH C18 column with acetonitrile and water as flow phase by gradient elution and determined by quadrupole mass spectrometer in negative selective ion monitoring mode. Usolic acid was used as internal standard. The calibration curves were linear over 0.02–3.0 µg/mL for TSN with a lower limit of quantification (LLOQ) of 20 ng/mL in rat plasma. The extraction recoveries of TSN were within 74.3–80.7% with an accuracy of 94.5–108.9%. The intra‐ and inter‐day precision values of the assay at three quality control levels were 8.8–13.8% and <13.9% at LLOQ level, respectively. The method was successfully applied to a pharmacokinetic study of TSN in rats after a single intravenous and oral administration of 2 and 60 mg/kg. The shorter Tmax, higher Vd and Cl of TSN after oral administration indicated that TSN could be absorbed, distributed and eliminated quickly in rats in vivo. The absolute bioavailability of TSN after oral administration was 9.9%. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
The analysis of synthetic cannabinoids in human matrices is of particular importance in the fields of forensic and clinical toxicology since cannabis users partly shift to the consumption of ‘herbal mixtures’ as a legal alternative to cannabis products in order to circumvent drug testing. However, comprehensive methods covering the majority of synthetic cannabinoids already identified on the drug market are still lacking. In this article, we present a fully validated method for the analysis of 30 synthetic cannabinoids in human serum utilizing liquid‐liquid extraction and liquid chromatography‐electrospray ionization tandem mass spectrometry. The method proved to be suitable for the quantification of 27 substances. The limits of detection ranged from 0.01 to 2.0 ng/mL, whereas the lower limits of quantification were in the range from 0.1 to 2.0 ng/mL. The presented method was successfully applied to 833 authentic serum samples during routine analysis between August 2011 and January 2012. A total of 227 (27%) samples was tested positive for at least one of the following synthetic cannabinoids: JWH‐018, JWH‐019, JWH‐073, JWH‐081, JWH‐122, JWH‐200, JWH‐203, JWH‐210, JWH‐307, AM‐2201 and RCS‐4. The most prevalent compounds in positive samples were JWH‐210 (80%), JWH‐122 (63%) as well as AM‐2201 (29%). Median serum concentrations were all below 1.0 ng/mL. These findings demonstrate a significant shift of the market of synthetic cannabinoids towards substances featuring a higher CB1 binding affinity and clearly emphasize that the analysis of synthetic cannabinoids in serum or blood samples requires highly sensitive analytical methods covering a wide spectrum of substances. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
Binding assays for the γ‐aminobutyric acid (GABA) transporter GAT3 can be assumed to significantly facilitate screening for respective inhibitors. As appropriate labeled ligands for this promising drug target are not available so far, we started efforts to set up mass spectrometry‐based binding assays (MS binding assays), for which labeled markers are not required. Therefore, we developed a sensitive and rapid LC‐ESI‐MS/MS quantification method for DDPM‐1007 {(RS)‐1‐[4,4,4‐Tris(4‐methoxyphenyl)but‐2‐en‐1‐yl]piperidine‐3‐carboxylic acid}, one of the most potent GAT3 inhibitors yet known, as a potential GAT3 marker. Using a 50 × 2 mm C8 column in combination with a mobile phase composed of 10 mm ammonium bicarbonate buffer pH 8.0 and acetonitrile (60:40, v/v) at a flow rate of 450 μL/min DDPM‐1007 could be analyzed in the positive multiple reaction monitoring mode [(m/z) 502.5 → 265.4] within a chromatographic cycle time of 3 min. Deuterated DDPM‐1007 [(2H9)DDPM‐1007] was synthesized and employed as internal standard. This way DDPM‐1007 could be quantified in a range from 100 pm to10 nm in the matrix resulting from respective binding experiments without any sample preparation. The established quantification method met the requirements of the FDA guidance for bioanalytical method validation concerning linearity and intra‐ and inter‐batch accuracy. Based on this LC‐ESI‐MS/MS quantification preliminary MS binding assays employing membrane preparations obtained from a stably GAT3 expressing HEK293 cell line and DDPM‐1007 as nonlabeled GAT3 marker could be performed. In these experiments specific binding of DDPM‐1007 at GAT3 could be unambiguously detected. Additionally, the established LC‐MS method provides a suitable analytical tool for further pharmacokinetic characterization of DDPM‐1007, as exemplified for its logD determination. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
A method for the determination of ethyl glucuronide (EtG) in hair samples, using liquid chromatography/electrospray tandem mass spectrometry (LC/ESI-MS/MS), was developed and validated. The treatment of hair samples was as follows: to 100 mg of washed (dichloromethane followed by methanol, 1 ml each) and cut (1-2 mm) material, 700 microl of water, 20 microl of internal standard solution (pentadeuterated EtG, D(5)-EtG, 500 microg/l) and 20 microl of methanol were added. Samples were incubated at 25 degrees C overnight and then ultrasonicated for 2 h. Finally, 8 microl of the centrifuged solution (13,000 rpm) were analyzed by LC/ESI-MS/MS in negative ion mode. The surviving ions of EtG and D(5)-EtG were monitored together with the following MRM transitions: m/z 221 --> 75, m/z 221 --> 85 (EtG) and m/z 226 --> 75, m/z 226 --> 85 (D(5)-EtG). The method exhibited a mean correlation coefficient better than 0.9998 over the dynamic range (3-2000 pg/mg). The lower limit of quantification (LLOQ) and the limit of detection (LOD) were 3 and 2 pg/mg respectively. The intra- and interday precision and accuracy were studied at four different concentration levels (3, 5, 56 and 160 pg/mg) and were always better than 7% (n = 5). Matrix effects did not exceed 20%. The method was applied to several hair samples taken from autopsies of known alcoholics, from patients in withdrawal treatment, from social drinkers, from adult teetotalers and from children not exposed to ethanol, with EtG concentrations globally ranging from < or =2 to 4180 pg/mg.  相似文献   

17.
A method for determining a novel phosphodiesterase‐4 inhibitor, 3‐[1‐(3cyclopropylmethoxy‐4‐difluoromethoxybenzyl)‐1H‐pyrazol‐3‐yl]‐benzoic acid (PDE‐423), in rat plasma was developed and validated using liquid chromatography–tandem mass spectrometry for further pharmacokinetic study for development as a novel anti‐asthmatic drug. PDE‐423 in the concentration range of 0.02–10 µg/mL was linear with a correlation coefficient of >0.99, and the mean intra‐ and inter‐assay precisions of the assay were 7.50 and 3.86%, respectively. The validated method was used successfully for a pharmacokinetic study of PDE‐423 in rats. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
Protein tyrosine nitration is associated with oxidative stress and various human diseases. Tandem mass spectrometry has been the method of choice for the identification and localization of this posttranslational modification to understand the underlying mechanisms and functional consequences. Due to the electron predator effect of the nitro group limiting fragmentation of the peptide backbone, electron‐based dissociation has not been applicable, however, to nitrotyrosine‐containing peptides. A straightforward conversion of the nitrotyrosine to the aminotyrosine residues is introduced to address this limitation. When tested with nitrated ubiquitin and human serum albumin as model proteins in top‐down and bottom‐up approaches, respectively, this chemical derivatization enhanced backbone fragmentation of the corresponding nitroproteins and nitropeptides by electron capture dissociation (ECD). Increased sequence coverage has been obtained by combining in the bottom‐up strategy the conversion of nitrotyrosine to aminotyrosine and introducing, in addition to trypsin, a further digesting enzyme of complementary specificity, when protein nitration was mapped by liquid chromatography–electrospray ionization tandem mass spectrometry using both collision‐induced dissociation (CID) and ECD. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
The mass spectrometric behavior of four pairs of stereoisomers was investigated by liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS). The E‐ and Z‐isomers of the pesticides chlorfenvinphos, dimethomorph, mevinphos and phosphamidon—each with one double bond—were chosen for this study. The MS response of the individual isomers was investigated by infusing the isomers individually into the MS or after the separation of isomer mixtures via high‐performance liquid chromatography(HPLC). In the case of dimethomorph, the same MS response was found for the two isomers. In contrast to that, the individual isomers of chlorfenvinphos, mevinphos and phosphamidon showed different MS response both in the single ion monitoring (SIM) mode in single quadrupole MS and multiple reaction monitoring (MRM) mode in tandem MS. The MS response of the isomers partly depends on (1) the declustering potential of the precursor ion in the SIM mode, (2) the selected transition and (3) the collision energy in the MRM mode. Consequently, quantification by summation of the peak areas of the isomers is inaccurate due to over‐ or underestimating of one of the stereoisomers. Accurate quantitative results can only be achieved when the compound‐specific MS parameters are separately determined for each isomer. This can be done by using pure isomers or by the determination of the MS parameters after HPLC separation and the measurement of the actual isomer ratio with an independent technique. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
Two new series of Boc‐N‐α,δ‐/δ,α‐ and β,δ‐/δ,β‐hybrid peptides containing repeats of L ‐Ala‐δ5‐Caa/δ5‐Caa‐L ‐Ala and β3‐Caa‐δ5‐Caa/δ5‐Caa‐β3‐Caa (L ‐Ala = L ‐alanine, Caa = C‐linked carbo amino acid derived from D ‐xylose) have been differentiated by both positive and negative ion electrospray ionization (ESI) ion trap tandem mass spectrometry (MS/MS). MSn spectra of protonated isomeric peptides produce characteristic fragmentation involving the peptide backbone, the Boc‐group, and the side chain. The dipeptide positional isomers are differentiated by the collision‐induced dissociation (CID) of the protonated peptides. The loss of 2‐methylprop‐1‐ene is more pronounced for Boc‐NH‐L ‐Ala‐δ‐Caa‐OCH3 (1), whereas it is totally absent for its positional isomer Boc‐NH‐δ‐Caa‐L ‐Ala‐OCH3 (7), instead it shows significant loss of t‐butanol. On the other hand, second isomeric pair shows significant loss of t‐butanol and loss of acetone for Boc‐NH‐δ‐Caa‐β‐Caa‐OCH3 (18), whereas these are insignificant for its positional isomer Boc‐NH‐β‐Caa‐δ‐Caa‐OCH3 (13). The tetra‐ and hexapeptide positional isomers also show significant differences in MS2 and MS3 CID spectra. It is observed that ‘b’ ions are abundant when oxazolone structures are formed through five‐membered cyclic transition state and cyclization process for larger ‘b’ ions led to its insignificant abundance. However, b1+ ion is formed in case of δ,α‐dipeptide that may have a six‐membered substituted piperidone ion structure. Furthermore, ESI negative ion MS/MS has also been found to be useful for differentiating these isomeric peptide acids. Thus, the results of MS/MS of pairs of di‐, tetra‐, and hexapeptide positional isomers provide peptide sequencing information and distinguish the positional isomers. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号