共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple technique for the collection of an extraction solvent lighter than water after dispersive liquid–liquid microextraction combined with high‐performance liquid chromatography with ultraviolet detection was developed for the determination of four paraben preservatives in aqueous samples. After the extraction procedure, low‐density organic solvent together with some little aqueous phase was separated by using a disposable glass Pasteur pipette. Next, the flow of the aqueous phase was stopped by successive dipping the capillary tip of the pipette into anhydrous Na2SO4. The upper organic layer was then removed simply with a microsyringe and injected into the high‐performance liquid chromatography system. Experimental parameters that affect the extraction efficiency were investigated and optimized. Under optimal extraction conditions, the extraction recoveries ranged from 25 to 86%. Good linearity with coefficients with the square of correlation coefficients ranging from 0.9984 to 0.9998 was observed in the concentration range of 0.001–0.5 μg/mL. The relative standard deviations ranged from 4.1 to 9.3% (n = 5) for all compounds. The limits of detection ranged from 0.021 to 0.046 ng/mL. The method was successfully applied for the determination of parabens in tap water and fruit juice samples and good recoveries (61–108%) were achieved for spiked samples. 相似文献
2.
Mir Ali Farajzadeh Djavanshir Djozan Nina Nouri Mehdi Bamorowat Mohammad Safi Shalamzari 《Journal of separation science》2010,33(12):1816-1828
Stir bar sorptive extraction (SBSE) combined with dispersive liquid–liquid microextraction (DLLME) has been developed as a new approach for the extraction of six triazole pesticides (penconazole, hexaconazole, diniconazole, tebuconazole, triticonazole and difenconazole) in aqueous samples prior to GC‐flame ionization detection (GC‐FID). A series of parameters that affect the performance of both steps were thoroughly investigated. Under optimized conditions, aqueous sample was stirred using a stir bar coated with octadecylsilane (ODS) and then target compounds on the sorbent (stir bar) were desorbed with methanol. The extract was mixed with 25 μL of 1,1,2,2‐tetrachloroethane and the mixture was rapidly injected into sodium chloride solution 30% w/v. After centrifugation, an aliquot of the settled organic phase was analyzed by GC‐FID. The methodology showed broad linear ranges for the six triazole pesticides studied, with correlation coefficients higher than 0.993, lower LODs and LOQs between 0.53–24.0 and 1.08–80.0 ng/mL, respectively, and suitable precision (RSD < 5.2%). Moreover, the developed methodology was applied for the determination of target analytes in several samples, including tap, river and well waters, wastewater (before and after purification), and grape and apple juices. Also, the presented SBSE‐DLLME procedure followed by GC‐MS determination was performed on purified wastewater. Penconazole, hexaconazole and diniconazole were detected in the purified wastewater that confirmed the obtained results by GC‐FID determination. In short, by coupling SBSE with DLLME, advantages of two methods are combined to enhance the selectivity and sensitivity of the method. This method showed higher enrichment factors (282–1792) when compared with conventional methods of sample preparation to screen pesticides in aqueous samples. 相似文献
3.
《Journal of separation science》2017,40(6):1343-1352
A simple method for the simultaneous and trace analysis of four synthetic food azo dyes including carmoisine, ponceau 4R, sunset yellow, and allura red from some foodstuff samples was developed by combining dispersive μ‐solid‐phase extraction and high‐performance liquid chromatography with diode array detection. Zein‐modified magnetic Fe3O4 nanoparticles were prepared and used for μ‐solid‐phase extraction of trace amounts of mentioned food dyes. The prepared modified magnetic nanoparticles were characterized by scanning electron microscopy and FTIR spectroscopy. The factors affecting the extraction of the target analytes such as pH, amount of sorbent, extraction time, type and volume of the desorption eluent, and desorption time were investigated. Under the optimized conditions, the method provided good repeatability with relative standard deviations lower than 5.8% (n = 9). Limit of detection values ranged between 0.3 and 0.9 ng/mL with relatively high enrichment factors (224–441). Comparing the obtained results indicated that Fe3O4 nanoparticles modified by zein biopolymer show better analytical application than bare magnetic nanoparticles. The proposed method was also applied for the determination of target synthetic food dyes in foodstuff samples such as carbonated beverage, snack, and candy samples. 相似文献
4.
In this study, a simple, rapid and sensitive method for the determination of five phthalates including dimethyl phthalate, diethyl phthalate, dipropyl phthalate, benzyl butyl phthalate, and dicyclohexyl phthalate in fruit jellies by LC coupled with MS has been developed. Samples were pretreated by a dispersive SPE method, termed QuEChERS, which is an acronym for quick, easy, cheap, effective, rugged, and safe. The standard calibration curves were linear for all the analytes over the concentration range of 10–250 ng/mL, and the correlation coefficients ranged from 0.9976 to 0.9991. The LODs and LOQs were in the ranges of 0.09–3.68 ng/mL and 0.28–11.25 ng/mL, respectively. The accuracy of this method was evaluated by measuring the recovery from spiked samples. The recoveries of all five phthalates from samples spiked at three different concentrations (0.01, 0.03, and 0.05 mg/kg), were in the ranges of 83.5–103.9%, 86.7–95.8%, and 87.1–95.2%, respectively. The RSD values for the samples spiked at 0.01, 0.03 , and 0.05 mg/kg ranged from 2.0–7.6%, 1.4–6.4%, and 1.2–3.8%, respectively. The method has been used for the analysis of real samples and BBP and DEP were found in real samples. 相似文献
5.
Ultrasonic nebulization extraction assisted dispersive liquid–liquid microextraction followed by gas chromatography for the simultaneous determination of six parabens in cosmetic products 下载免费PDF全文
A simple, rapid, and efficient method of ultrasonic nebulization extraction assisted dispersive liquid–liquid microextraction was developed for the simultaneous determination of six parabens in cosmetic products. The analysis was carried out by gas chromatography. Water was used as the dispersive solvent instead of traditional organic disperser. The experimental factors affecting the extraction yield, such as the extraction solvent and volume, extraction time, dispersive solvent and volume, ionic strength, and centrifuging condition were studied and optimized in detail. The limit of detections for the target analytes were in the range of 2.0–9.5 μg/g. Good linear ranges were obtained with the coefficients ranging from 0.9934 to 0.9969. The proposed method was successfully applied to the analysis of six parabens in 16 cosmetic products. The recoveries of the target analytes in real samples ranged from 81.9 to 108.7%, and the relative standard deviations were <5.3%. 相似文献
6.
SPE coupled with dispersive liquid–liquid microextraction followed by GC with flame ionization detection for the determination of ultra‐trace amounts of benzodiazepines 下载免费PDF全文
Masoomeh Ghobadi Yadollah Yamini Behnam Ebrahimpour 《Journal of separation science》2014,37(3):287-294
SPE combined with dispersive liquid–liquid microextration was used for the extraction of ultra‐trace amounts of benzodiazepines (BZPs) including, diazepam, midazolam, and alprazolam, from ultra‐pure water, tap water, fruit juices, and urine samples. The analytes were adsorbed from large volume samples (60 mL) onto octadecyl silica SPE columns. After the elution of the desired compounds from sorbents with 2.0 mL acetone, 0.5 mL of eluent containing 40.0 μL chloroform was injected rapidly into 4.5 mL pure water. After extraction and centrifugation, 2 μL of the sedimented phase was injected into a GC equipped with a flame ionization detector. Several parameters affecting this process were investigated and optimized. Under the optimal conditions, LODs ranged from 0.02 to 0.05 μg/L, a linear dynamic range of 0.1–100 μg/L and relative SDs in the range of 4.4–10.7% were attained. Very high preconcentration factors ranging from 3895–7222 were achieved. The applicability of the method for the extraction of BZPs from different types of complicated matrices, such as tap water, fruit juices, and urine samples, was studied. The obtained results reveal that the proposed method is a good technique for the extraction and determination of BZPs in complex matrices. 相似文献
7.
Extraction of phenolic compounds from water samples by dispersive micro‐solid‐phase extraction 下载免费PDF全文
In this article, the use of magnetically separable sorbent polyaniline/silica‐coated nickel nanoparticles is evaluated under a dispersive micro‐solid‐phase extraction approach for the extraction of phenolic compounds from water samples. The sorbent was prepared by in situ chemical polymerization of aniline on the surface of silica‐modified nickel nanoparticles and was characterized by Fourier transform infrared spectroscopy, transmission electron microscopy, X‐ray powder diffraction, scanning electron microscopy, energy‐dispersive X‐ray spectrometry, and vibrating sample magnetometry. Effective variables such as amount of sorbent (milligrams), pH and ionic strength of sample solution, volume of eluent solvent (microliters), vortex, and ultrasonic times (minutes) were investigated by fractional factorial design. The significant variables optimized by a Box–Behnken design were combined by a desirability function. Under the optimized conditions, the calibration graphs of analytes were linear in a concentration range of 0.02–100 μg/mL, and with correlation coefficients more than 0.999. The limits of detection and quantification were in the ranges of 10–23 and 33–77 μg/L, respectively. This procedure was successfully employed in the determination of target analytes in spiked water samples; the relative mean recoveries ranged from 96 to 105%. 相似文献
8.
Maryam Vosough Nahal Rahimdoost Mojdehi Amir Salemi 《Journal of separation science》2012,35(24):3575-3585
In the present study, dispersive liquid–liquid microextraction followed by high performance liquid chromatography‐diode array detection has been developed as simple, rapid, accurate, and efficient sample preparation method for simultaneous determination of seven organic UV filters in urine samples. The influence of the main effects as well as their interactions was studied through a 2(6–2) fractional factorial design. The candidate parameters were: type and volume of dispersant and extraction solvents, sample pH, and salt concentration. Under final optimal conditions, the analytes were extracted from 5 mL of samples by addition of 0.5 mL of acetonitrile (dispersing solvent) containing 70 μL of carbon tetrachloride (extraction solvent), without modifying the pH of the solution and applying the (+1) level of salt concentration (10% w/v NaCl). The assay was linear (R2 > 0.997), relative recoveries ranged from 86.9 up to 97.3% and the LOQs between 3 and 45 ng mL?1 were obtained. The intra‐ and interday RSDs were lower than 5 and 8% at the middle point of the linear range, respectively. The proposed method was successfully applied to different volunteer urine samples and it was shown that the extraction efficiency was not affected by the type of urine samples. 相似文献
9.
We have prepared a solid phase for the extraction of chlorobenzenes (CBs) by coating magnetic (Fe3O4) nanoparticles with silica via a sol‐gel process using a mixture of tetraethoxysilane and triethoxyphenylsilane. The nanoparticles were characterized by SEM, energy‐dispersive spectroscopy, and X‐ray diffractometry. The nanoparticles were used for the extraction of 1,4‐dichlorobenzene (1,4‐DCB), 1,2,3‐trichlorobenzene (1,2,3‐TCB), 1,2,4‐trichlorobenzene (1,2,4‐TCB), and 1,2,3,4‐tetrachlorobenzene (1,2,3,4‐TeCB) from water, followed by their determination by GC‐electron capture detection. Under optimal conditions, enrichment factors ranging from 220 to 360 were obtained. All determination coefficients (r2) are >0.99, and linear response is found in range 0.025–1.5 μg/L (at the lower end), and 6–120 μg/L (at the higher end). Detection limits are 6, 10, 11, and 500 ng/L for 1,2,3,4‐TeCB, 1,2,4‐TCB, 1,2,3‐TCB, and 1,4‐DCB, respectively. All RSDs are <6% (for n = 5). The method was successfully applied to the determination of CBs in environmental water samples. 相似文献
10.
Jiao Jiao Qing‐Yan Gai Wei Wang Meng Luo Chun‐Jian Zhao Yu‐Jie Fu Wei Ma 《Journal of separation science》2013,36(23):3799-3806
A rapid, green and effective miniaturized sample preparation technique, ionic‐liquid‐assisted microwave distillation coupled with headspace single‐drop microextraction was developed for the extraction of essential oil from dried Dryopteris fragrans. 1‐Ethyl‐3‐methylimidazolium acetate was the optimal ionic liquid as the destruction agent of plant cell walls and microwave absorption was medium. n‐Heptadecane (2.0 μL) was adopted as the suspended microdrop solvent in the headspace for the extraction and concentration of essential oil. The optimal parameters of the proposed method were an irradiation power of 300 W, sample mass of 0.9 g, mass ratio of ionic liquids to sample of 2.8, extraction temperature of 79°C, and extraction time of 3.6 min. In comparison to the previous reports, the proposed technique could equally monitor all the essential oil components with no significant differences in a simple way, which was more rapid and required a much lower amount of sample. 相似文献
11.
《Journal of separation science》2017,40(22):4394-4402
A novel liquid–liquid microextraction method, namely, solvent‐vapor‐assisted liquid–liquid microextraction for the determination of dimethyl phthalate, diethyl phthalate, dibutyl phthalate and bis(2‐ethylhexyl) phthalate in the aqueous samples using gas chromatography with mass spectrometry was developed. In the proposed method, extracting solvent was heated, and solvent vapor as the extracting phase was injected into the sample solution. As a result of the low temperature of the sample solution and higher density of the extracting phase than the aqueous medium, solvent vapor was condensed and an organic‐phase drop formed in the bottom of sample tube. Because of the gas status of the extracting solvent, the surface area between the extracting solvent and the aqueous sample was remarkably high. Under the optimized conditions, tetrachloride carbon was used as an extracting solvent. The method shows high coefficient of determination (R 2) values in the range of 0.5–200 and 1.0–200 ng/mL for the target analytes. Enrichment factors and limits of detection for the studied phthalates are obtained in the ranges of 2800–3000 and 0.15–0.3 ng/mL, respectively. Recoveries and relative standard deviations were in the range of 80.0–100.0 and 2.2–7.8%, respectively. The proposed method successfully used for analysis of several aqueous samples. 相似文献
12.
Determination of atenolol in human plasma using ionic‐liquid‐based ultrasound‐assisted in situ solvent formation microextraction followed by high‐performance liquid chromatography 下载免费PDF全文
An efficient analytical method called ionic‐liquid‐based ultrasound‐assisted in situ solvent formation microextraction followed by high‐performance liquid chromatography was developed for the determination of atenolol in human plasma. A hydrophobic ionic liquid (1‐butyl‐3‐methylimidazolium hexafluorophosphate) was formed by the addition of a hydrophilic ionic liquid (1‐butyl‐3‐methylimidazolium tetrafluoroborate) to a sample solution containing an ion‐pairing agent during microextraction. The analyte was extracted into the ionic liquid phase while the microextraction solvent was dispersed throughout the sample by utilizing ultrasound. The sample was then centrifuged, and the extracting phase retracted into the microsyringe and injected to liquid chromatography. After optimization, the calibration curve showed linearity in the range of 2–750 ng/mL with the regression coefficient corresponding to 0.998. The limits of detection (S/N = 3) and quantification (S/N = 10) were 0.5 and 2 ng/mL, respectively. A reasonable relative recovery range of 90–96.7% and satisfactory intra‐assay (4.8–5.1%, n = 6) and interassay (5.0–5.6%, n = 9) precision along with a substantial sample clean‐up demonstrated good performance of the procedure. It was applied for the determination of atenolol in human plasma after oral administration and some pharmacokinetic data were obtained. 相似文献
13.
A single‐drop microextraction (SDME) method followed by in‐syringe derivatization and GC‐MS determination has been developed for analysis of five parabens, including methyl, ethyl, isopropyl, n‐propyl and n‐butyl paraben in water samples and cosmetic products. N,O‐Bis(trimethylsilyl)acetamide (BSA) was used as derivatization reagent. Derivatization reaction was performed inside the syringe barrel using 0.4 μL of BSA. Parameters that affect the derivatization yield such as temperature and time of the reaction were studied. In addition, experimental SDME parameters such as selection of organic solvent, addition of salt, extraction time and extraction temperature were investigated and optimized. The RSD of the method for aqueous samples varied from 8.1 to 13%. The LODs ranged from 0.001 (n‐butyl paraben) to 0.015 (methyl paraben) μg/L, and the enrichment factors were between 23 and 150. 相似文献
14.
This paper described a novel approach for the determination of bisphenol A by dispersive liquid‐phase microextraction with in situ acetylation prior to GC‐MS. In this derivatization/extraction method, 500 μL acetone (disperser solvent) containing 30.0 μL chlorobenzene (extraction solvent) and 30.0 μL acetic anhydride (derivatization reagent) was rapidly injected into 5.00 mL aqueous sample containing bisphenol A and K2CO3 (0.5% w/v). Within a few seconds the analyte was derivatized and extracted at the same time. After centrifugation, 1.0 μL of sedimented phase containing enriched analyte was determined by GC‐MS. Some important parameters, such as type and volume of extraction and disperser solvent, volume of acetic anhydride, derivatization and extraction time, amount of K2CO3, and salt addition were studied and optimized. Under the optimum conditions, the LOD and the LOQ were 0.01, 0.1 μg/L, respectively. The experimental results indicated that there was linearity over the range 0.1–50 μg/L with coefficient of correlation 0.9997, and good reproducibility with RSD 3.8% (n = 5). The proposed method has been applied for the analysis of drinking water samples, and satisfactory results were achieved. 相似文献
15.
Mojtaba Shamsipur Nazir Fattahi Meghdad Pirsaheb Kiomars Sharafi 《Journal of separation science》2012,35(20):2718-2724
Dispersive liquid–liquid microextraction coupled with high‐performance liquid chromatography‐ultraviolet detection as a fast and inexpensive technique was applied to the simultaneous extraction and determination of traces of three common herbicides, 2,4‐D, alachlor and atrazine, in aqueous samples. The critical experimental parameters, including type of the extraction and disperser solvents as well as their volumes, sample pH, salt addition, extraction time and centrifuging time, and speed were investigated and optimized. Under the optimum conditions, the calibration graphs found to be linear in the range of 0.3–200 μg/L with limits of detection in the range of 0.05–0.1 μg/L. The relative standard deviations were in the range of 4.5–6.2% (n = 7). The relative recoveries of well, tap, and river water samples which have been spiked with different levels of herbicides were 92.0–107.0, 82.0–104.0, and 82.0–86.0%, respectively. 相似文献
16.
Dispersive solid‐phase extraction followed by vortex‐assisted dispersive liquid–liquid microextraction based on the solidification of a floating organic droplet for the determination of benzoylurea insecticides in soil and sewage sludge 下载免费PDF全文
Guilong Peng Qiang He Daniel Mmereki Ying Lu Zhihui Zhong Hanyang Liu Weiliang Pan Guangming Zhou Junhua Chen 《Journal of separation science》2016,39(7):1258-1265
A novel dispersive solid‐phase extraction combined with vortex‐assisted dispersive liquid–liquid microextraction based on solidification of floating organic droplet was developed for the determination of eight benzoylurea insecticides in soil and sewage sludge samples before high‐performance liquid chromatography with ultraviolet detection. The analytes were first extracted from the soil and sludge samples into acetone under optimized pretreatment conditions. Clean‐up of the extract was conducted by dispersive solid‐phase extraction using activated carbon as the sorbent. The vortex‐assisted dispersive liquid–liquid microextraction based on solidification of floating organic droplet procedure was performed by using 1‐undecanol with lower density than water as the extraction solvent, and the acetone contained in the solution also acted as dispersive solvent. Under the optimum conditions, the linearity of the method was in the range 2–500 ng/g with correlation coefficients (r) of 0.9993–0.9999. The limits of detection were in the range of 0.08–0.56 ng/g. The relative standard deviations varied from 2.16 to 6.26% (n = 5). The enrichment factors ranged from 104 to 118. The extraction recoveries ranged from 81.05 to 97.82% for all of the analytes. The good performance has demonstrated that the proposed methodology has a strong potential for application in the multiresidue analysis of complex matrices. 相似文献
17.
Qinhua Chen Peng Li Fangjun Yuan Fanjun Cheng Jing He Jia Liu Zhuo Zhang 《Journal of separation science》2009,32(2):252-257
The volatile components of Cnidium monnieri were obtained by supercritical fluid extraction (SFE) and analyzed by GC‐MS (identification and determination of metabolites). The compounds were identified according to their retention times and mass spectra. The effects of different parameters, such as extraction pressure, temperature, dynamic extraction time, flow rate of CO2, on the SFE of C. monnieri extracts were investigated. A total of 14 compounds of SFE extracts were identified. Osthole (69.52%), bornyl acetate (10.03%), α‐pinene (4.71%), and imperatorin (2.42%) were the major compounds identified in C. monnieri SFE extracts. The quantitation of osthole and imperatorin were then accomplished. The linear calibration ranges were all 5–1000 μg/mL for osthole and imperatorin by GC‐MS analysis. The recovery of osthole and imperatorin were in the range 96.5–101.8%. The LODs for osthole and imperatorin were 1.0 and 0.6 μg/mL, respectively. 相似文献
18.
Low‐density‐solvent‐based air‐assisted liquid–liquid microextraction followed by gas chromatography with flame ionization detection for the determination of synthetic phenolic antioxidants in milk samples 下载免费PDF全文
Mir Ali Farajzadeh Mohammad Reza Afshar Mogaddam 《Journal of separation science》2016,39(6):1160-1167
A simple and rapid sample pretreatment technique termed low‐density‐solvent‐based air‐assisted liquid–liquid microextraction has been developed for the extraction and preconcentration of three synthetic phenolic antioxidants including butylated hydroxyanisole, butylated hydroxytoluene, and tert‐butyl hydroquinone from milk samples prior to their analysis by gas chromatography with flame ionization detection. In this method, initially trichloroacetic acid as a proteins precipitation agent is added to the sample, and then it is sonicated and centrifuged. The obtained aqueous phase is removed and the analytes extracted by the proposed method using a low‐density organic solvent. Some important parameters such as type and volume of extraction solvent, ionic strength, pH, and centrifugation rate and time were studied. Under the optimum conditions, enrichment factors were obtained in the range of 501–614. LODs and quantification were between 0.76–1.16 and 2.66–3.96 ng mL–1, respectively. This method is rapid and requires less than 15 min for sample preparation. 相似文献
19.
Determination of zearalenone in maize products by vortex‐assisted ionic‐liquid‐based dispersive liquid–liquid microextraction with high‐performance liquid chromatography 下载免费PDF全文
Lin Wang Chuanlei Luan Fangfang Chen Rui Wang Lihua Shao 《Journal of separation science》2015,38(12):2126-2131
A novel method has been developed for the analysis of zearalenone in maize products by vortex‐assisted ionic‐liquid‐based dispersive liquid–liquid microextraction combined with HPLC and fluorescence detection. Maize samples were extracted with methanol/water (80:20, v/v) and the extraction solution was then used as the dispersive solvent in the microextraction procedure. The analyte was rapidly transmitted to a small volume of ionic liquid and was determined by HPLC. Various parameters affecting the recovery of the mycotoxin were investigated, such as the type and volume of the extraction solvent, the type and volume of the dispersive solvent, the pH of the aqueous phase, the salt addition, and the time of vortex and centrifugation. Under the optimal experimental conditions, a good linearity of the analyte was obtained in the range of 1.0–1000.0 μg/L with the correlation coefficient of 0.9998. The limit of detection (S/N = 3) and quantification (S/N = 10) were 0.3 and 1.0 μg/kg, and the mean recoveries ranged from 83.5 to 94.9%, with a relative standard deviation less than 5.0%. The proposed method was demonstrated to be simple, cheap, quick, and highly selective and was successfully applied to the determination of zearalenone in maize products. 相似文献
20.
Effervescence‐assisted dispersive solid‐phase extraction using ionic‐liquid‐modified magnetic β‐cyclodextrin/attapulgite coupled with high‐performance liquid chromatography for fungicide detection in honey and juice 下载免费PDF全文
Xiaoling Wu Miyi Yang Haozhe Zeng Xuefei Xi Sanbing Zhang Runhua Lu Haixiang Gao Wenfeng Zhou 《Journal of separation science》2016,39(22):4422-4428
In this study, a simple effervescence‐assisted dispersive solid‐phase extraction method was developed to detect fungicides in honey and juice. Most significantly, an innovative ionic‐liquid‐modified magnetic β‐cyclodextrin/attapulgite sorbent was used because its large specific surface area enhanced the extraction capacity and also led to facile separation. A one‐factor‐at‐a‐time approach and orthogonal design were employed to optimize the experimental parameters. Under the optimized conditions, the entire extraction procedure was completed within 3 min. In addition, the calibration curves exhibited good linearity, and high enrichment factors were achieved for pure water and honey samples. For the honey samples, the extraction efficiencies for the target fungicides ranged from 77.0 to 94.3% with relative standard deviations of 2.3–5.44%. The detection and quantitation limits were in the ranges of 0.07–0.38 and 0.23–1.27 μg/L, respectively. Finally, the developed technique was successfully applied to real samples, and satisfactory results were achieved. This analytical technique is cost‐effective, environmentally friendly, and time‐saving. 相似文献