首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel, sensitive, and reliable LC‐MS/MS method for multiresidue analysis of nine β‐agonists (salbutamol, terbutaline, cimaterol, fenoterol, clorprenaline, ractopamine, tulobuterol, clenbuterol, and penbuterol) in four farm animal muscles was developed. Muscle matrix was extracted with acetonitrile–10% sodium carbonate solution, and then was subjected to cleanup using a SPE cartridge packed with new polymer synthesized in acetone. Chromatographic separation of the components was performed on a Luna C18 column using 0.1% of formic acid in water and acetonitrile. The mass spectrometer was operated in the positive electrospray mode. Good precision and accuracy were obtained for all analytes (except for fenoterol) at the spiked three levels of 1.0, 10, and 50 μg/kg. The decision limit and detection capability of nine β‐agonists ranged from 0.04 to 0.18 and 0.15 to 0.69 μg/kg, respectively. The method developed was successfully applied to the monitoring of nine β‐agonists in pork, beef, mutton, and chicken from Chinese markets.  相似文献   

2.
Salbutamol (SAL) is the most widely used β2‐agonist drug for asthma and chronic obstructive pulmonary patients, but it is also often abused as feed additive. In recent years, the abuse of SAL has led to a large number of food safety incidents. Therefore, the monitoring of SAL residues in animal products is very important. A highly selective boronate affinity magnetic adsorbent was synthesized and developed for detection of trace levels of SAL residues in pig tissue samples. The obtained Fe3O4@SiO2@FPBA(4‐formylphenylboronic acid) magnetic adsorbent showed good adsorption ability to catechol and SAL, and then it was successfully applied as special magnetic solid‐phase phase extraction adsorbent coupled with high‐performance liquid chromatography (HPLC) for simultaneous isolation and determination of cis‐diol compounds. The binding capacity of catechol and SAL reached 96 and 50 µmol/g, respectively. The method was successfully established for the detection of trace levels of SAL in pig tissue samples. The linear range extended from 0.32 to 800 µg/kg (R2 = 0.9994). The limit of detection of SAL was 0.19 µg/kg. The recoveries were satisfactory (89.5–108.0%) at three spiked levels with RSD between 2.1 and 11.3%. These results indicated that the method has potential for enrichment and detection of trace levels of SAL residual in animal food products. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

3.
A highly sensitive and selective method using LC‐ESI‐MS/MS and tandem‐SPE was developed to detect trace amounts of avoparcin (AV) antibiotics in animal tissues and milk. Data acquisition using MS/MS was achieved by applying multiple reaction monitoring of the product ions of [M + 3H]3+ and the major product ions of AV‐α and ‐β at m/z 637 → 86/113/130 and m/z 649 → 86/113/130 in ESI(+) mode. The calculated instrumental LODs were 3 ng/mL. The sample preparation was described that the extraction using 5% TFA and the tandem‐SPE with an ion‐exchange (SAX) and InertSep C18‐A cartridge clean‐up enable us to determine AV in samples. Ion suppression was decreased by concentration rates of each sample solution. These SPE concentration levels could be used to detect quantities of 5 ppb (milk), 10 ppb (beef), and 25 ppb (chicken muscle and liver). The matrix matching calibration graphs obtained for both AV‐α (r >0.996) and ‐β (r >0.998) from animal tissues and milk were linear over the calibration ranges. AV recovery from samples was higher than 73.3% and the RSD was less than 12.0% (n = 5).  相似文献   

4.
Scientific evidence has shown an association between organochlorine compounds (OCC) exposure and human health hazards. Concerning this, OCC detection in human adipose samples has to be considered a public health priority. This study evaluated the efficacy of various solid‐phase extraction (SPE) and cleanup methods for OCC determination in human adipose tissue. Octadecylsilyl endcapped (C18‐E), benzenesulfonic acid modified silica cation exchanger (SA), poly(styrene‐divinylbenzene (EN) and EN/RP18 SPE sorbents were evaluated. The relative sample cleanup provided by these SPE columns was evaluated using gas chromatography with electron capture detection (GC–ECD). The C18‐E columns with strong homogenization were found to provide the most effective cleanup, removing the greatest amount of interfering substance, and simultaneously ensuring good analyte recoveries higher than 70%. Recoveries > 70% with standard deviations (SD) < 15% were obtained for all compounds under the selected conditions. Method detection limits were in the 0.003–0.009 mg/kg range. The positive samples were confirmed by gas chromatography coupled with tandem mass spectrometry (GC‐MS/MS). The highest percentage found of the OCC in real samples corresponded to HCB, o,p′‐DDT and methoxychlor, which were detected in 80 and 95% of samples analyzed respectively. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
A very accurate and selective LC‐MS/MS method was developed and validated for the quantification of 2′‐C‐modified nucleoside triphosphate in liver tissue samples. An efficient pretreatment procedure of liver tissue samples was developed, using a fully automated SPE procedure with 96‐well SPE plate (weak anion exchange sorbent, 30 mg). Nucleotide hydrophilic interaction chromatography has been performed on an aminopropyl column (100 mm×2.0 mm, 3 μm) using a gradient mixture of ACN and ACN/water (5:95 v/v) with 20 mM ammonium acetate at pH 9.45 as mobile phase at 300 μL/min flow rate. The 2′‐C‐modified nucleoside triphosphate was detected in the negative ESI mode in multiple reaction monitoring (MRM) mode. Calibration curve was linear over the 0.05–50 μM concentration range. Satisfying results, confirming the high reliability of the established LC‐MS/MS method, were obtained for intraday precision (CV = 2.5–9.1%) and accuracy (92.6–94.8%) and interday precision (CV = 9.6–11.5%) and accuracy (94.4–102.4%) as well as for recovery (82.0–112.6%) and selectivity. The method has been successfully applied for pharmacokinetic studies of 2′‐C‐methyl‐cytidine‐triphosphate in liver tissue samples.  相似文献   

6.
This paper presents a selective and efficient sample preparation procedure for NLLGLIEAK, signature peptide for the small cell lung cancer (SCLC) biomarker ProGRP, in human serum. The procedure is based on immuno‐capture of ProGRP in 96‐wells microtiter plates coated with the mAb E146. After immuno‐capture and thorough rinse, trypsin was added for in‐well digestion. Subsequently the signature peptide was enriched by SPE and determined by LC‐MS/MS. Various steps in the procedure were optimized to achieve a low LOD such as dilution of sample, tryptic digestion, and SPE cleanup and peptide enrichment conditions. A single quadropole MS was used during optimization of the method. A triple quadropole MS was used in the method evaluation in order to improve sensitivity. The evaluation showed good repeatability (RSD, 11.9–17.5%), accuracy (3.0–6.6%), and linearity (r2 = 0.995) in the tested range (0.5–50 ng/mL). LOD and LOQ were in the pg/mL area (0.20 and 0.33 ng/mL, respectively), enabling the determination of clinically relevant concentrations. The method was applied to two patient samples and showed good agreement with an established immunological reference method. The final method was compared to a previous published LC‐MS method for the determination of ProGRP in serum based on protein precipitation and online sample cleanup. Both showed acceptable method performance, however, the immuno‐capture LC‐MS method was superior with respect to sensitivity. This illustrates the large potential of immuno‐capture sample preparation prior to LC‐MS in protein biomarker quantification.  相似文献   

7.
An efficient and sensitive multiresidue method has been developed for quantification and confirmation of 25 phenyl acetanilide pesticides in a wide variety of food commodities including maize, spinach, mushroom, apple, soybean, chestnut, tea, beef, cattle liver, chicken, fish, and milk. Analytes were extracted with acetone–n‐hexane (1:2, v/v) followed by cleanup using SPE. Several types of adsorbents were evaluated. Neutral aluminum and graphitized carbon black cartridge showed good cleanup efficiency. The extract was determined by GC‐MS in the selected ion monitoring mode using one target and two qualitative ions for each analyte. The limits of detection were 0.01 mg/kg for all analytes. The average recoveries ranged from 66.9 to 110.6% (mean 88.8%) and RSDs were in the range 2.0–19% (mean 10.5%) across three fortification levels. The proposed method was successfully applied to real samples in routine analysis and a satisfactory result was obtained.  相似文献   

8.
Non‐aqueous capillary electrophoresis–mass spectrometry (NACE‐MS) was developed for trace analyses of β‐agonists (i.e. clenbuterol, salbutamol and terbutaline) in pork. The NACE was in 18 mM ammonium acetate in methanol–acetonitrile–glacial acetic acid (66 : 33 : 1, v/v/v) using a voltage of 28 kV. The hyphenation of CE with a time‐of‐flight MS was performed by electrospray ionization interface employing 5 mM ammonium acetate in methanol–water (80 : 20, v/v) as the sheath liquid at a flow rate of 2 μL/min. Method sensitivity was enhanced by a co‐injection technique (combination of hydrodynamic and electrokinetic injection) using a pressure of 50 mbar and a voltage of 10 kV for 12 s. The method was validated in comparison with HPLC–MS‐MS. The NACE‐MS procedure provided excellent detection limits of 0.3 ppb for all analytes. Method linearity was good (r2 > 0.999, in a range of 0.8–1000 ppb for all analytes). Precision showed %RSDs of <17.7%. Sample pre‐treatment was carried out by solid‐phase extraction using mixed mode reversed phase/cation exchange cartridges yielding recoveries between 69 and 80%. The NACE‐MS could be successfully used for the analysis of β‐agonists in pork samples and results showed no statistical differences from the values reported by the Ministry of Public Health, Thailand using HPLC‐MS‐MS method. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
A sensitive liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method for simultaneous determination of R‐bambuterol and its active metabolite R‐terbutaline in human plasma and urine was established. The inhibition for the biotransformation of R‐bambuterol in plasma was fully investigated. Plasma samples were prepared on ice and neostigmine metilsulfate added as a cholinesterase inhibitor immediately after sample collection. All samples were extracted with ethyl acetate and separated on a C18 column under gradient elution with a mobile phase consisting of methanol and water containing 5 mm ammonium acetate at a flow rate of 0.6 mL/min. The analytes were detected by an API 4000 tandem mass spectrometer with positive electrospray ionization in multiple reaction monitoring mode. The established method was highly sensitive with the lower limit of quantification (LLOQ) of 10.00 pg/mL for each analyte in plasma. In urine samples, the LLOQs were 20.00 and 500.0 pg/mL for R‐bambuterol and R‐terbutaline, respectively. The intra‐ and inter‐day precisions were <12.7 and <8.6% for plasma and urine, respectively. The analytical runtime within 6.0 min per sample made this method suitable for high‐throughput determination. The validated method has been successfully applied to the human pharmacokinetic study of R‐bambuterol involving 10 healthy volunteers. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
Tobacco‐specific N‐nitrosamines (TSNAs), including N′‐nitrosonornicotine, 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanone, N′‐nitrosoanatabine, and N′‐nitrosoanabasine, have been implicated as a source of carcinogenicity in tobacco and cigarette smoke. We present a rapid and effective method comprising SPE based on tetraazacalix[2]arene[2]triazine‐modified silica as sorbent and analysis with HPLC–MS/MS for the determination of TSNAs and 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanol (NNAL), a metabolite of 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanone, in rabbit plasma. The linear dynamic ranges were 10–2000 pg/mL for NNAL and 4–2000 pg/mL for the four TSNAs with good correlation coefficients (>0.9965). The LODs were in the range of 0.9–3.7 pg/mL, and the LOQs were between 2.9 and 12.3 pg/mL. The accuracies of the method were also evaluated and found to be in the range of 90.1–113.3%. This method is promising to be applied to the preconcentration and determination of TSNAs and NNAL in smoke and human body fluids.  相似文献   

11.
The enantio‐separations of eight 2‐arylpropionic acid nonsteroidal anti‐inflammatory drugs (2‐APA NSAIDs) were established using reversed‐phase high‐performance liquid chromatography with hydroxypropyl‐β‐cyclodextrin (HP‐β‐CD) as chiral mobile phase additive for studying the stereoselective skin permeation of suprofen, ketoprofen, naproxen, indoprofen, fenoprofen, furbiprofen, ibuprofen and carprofen. The effects of the mobile phase composition, concentration of HP‐β‐CD and column temperature on retention and enantioselective separation were investigated. With 2‐APA NSAIDs as acidic analytes, the retention times and resolutions of the enantiomers were strongly related to the pH of the mobile phase. In addition, both the concentration of HP‐β‐CD and temperature had a great effect on retention time, but only a slight or almost no effect on resolutions of the analytes. Enantioseparations were achieved on a Shimpack CLC‐ODS (150 × 4.6 mm i.d., 5 μm) column. The mobile phase was a mixture of methanol and phosphate buffer (pH 4.0–5.5, 20 mM) containing 25 mM HP‐β‐CD. This method was flexible, simple and economically advantageous over the use of chiral stationary phase, and was successfully applied to the enantioselective determination of the racemic 2‐APA NSAIDs in an enantioselective skin permeation study. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
A simple and rapid method was developed for the determination of three free cytokinins, namely, N6‐(Δ2‐isopentenyl)adenine, zeatin, and dihydrozeatin, in plants using TurboFlow on‐line cleanup liquid chromatography combined with hybrid quadrupole‐Orbitrap high‐resolution mass spectrometry. The samples were extracted using acetonitrile, and then the extract was purified on a C18‐p column, in which the sample matrix was removed and the analytes were retained. Subsequently, the analytes were eluted from the extraction column onto the analytical column (Hypersil Gold C18 column) prior to chromatographic separation and hybrid Q‐Orbitrap detection using the targeted‐MS2 scan mode. The linearity was satisfactory with a correlation coefficient of >0.999 at concentrations ranging from 5–5000 pg/mL. The limits of quantification for the analytes ranged from 4.2–5.2 pg/mL. The intra‐ and inter‐day average recoveries of analytes fortified at three levels ranged from 85.4–108.2%, and the intra‐ and inter‐day relative standard deviations ranged from 4.04–8.57%. The method was successfully applied for the determination of free cytokinins in different tissue samples of Oryza sativa and Arabidopsis thaliana.  相似文献   

13.
Automated online SPE‐HPLC‐MS was established for the determination of deca‐bromodiphenyl ether in human serum. The online SPE with large volume injection was utilized to enhance the sensitivity. Online SPE with dilution line greatly decreased matrices effect, which enabled serum samples to be injected directly into pre‐column. Washing line was designed for the system to solve the serious residual phenomenon and reduce the risk of sample wastage and contamination. Under the optimized conditions, the linear of the method was in the range 0.1–10 ng/mL with the LOD of 0.026 ng/mL. The recoveries of serum samples spiked with deca‐bromodiphenyl ether at 0.5 ng/mL was in the range from 83.30 to 102.7% with RSD in interday less than 8.67%. The satisfactory results demonstrated that the method of online sample pretreatment and cleanup recycle were reliable for human serum analysis.  相似文献   

14.
A sensitive and selective liquid chromatography–tandem mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of β,β‐dimethylacrylshikonin (DASK) in rat whole blood. DASK was pretreated using pre‐column derivatization with 2‐mercaptoethanol followed by liquid–liquid extraction with cyclohexane. Detection was performed on Thermo Finnigan TSQ Quantum triple quadrupole mass spectrometer by selected reaction monitoring mode via electrospray ionization source. The linear range for the determination of DASK spiked in rat whole blood (0.25 mL) was 3–3000 ng/mL. The accuracy was within 9%. Intra‐ and inter‐day precisions were no more than 16.1 and 13.3%, respectively. The validated LC‐MS/MS method was successfully applied to the preliminary pharmacokinetic study in rats. After DASK administration (60 mg/kg, p.o.) in rats, pharmacokinetic parameters were obtained, where the area under the drug concentration–time curve was 2393.7 ± 224.4 ng h/mL and the elimination half‐life was 27.6 ± 5.3 h. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

15.
Complementary and alternative medicines (CAM) can affect the pharmacokinetics of anticancer drugs by interacting with the metabolizing enzyme cytochrome P450 (CYP) 3A4. To evaluate changes in the activity of CYP3A4 in patients, levels of 1‐hydroxymidazolam in plasma are often determined with liquid chromatography–quadrupole mass spectrometry (LC‐MS/MS). However, validated LC‐MS/MS methods to determine in vitro CYP3A4 inhibition in human liver microsomes are scarce and not optimized for evaluating CYP3A4 inhibition by CAM. The latter is necessary because CAM are often complex mixtures of numerous compounds that can interfere with the selective measurement of 1‐hydroxymidazolam. Therefore, the aim was to validate and optimize an LC‐MS/MS method for the adequate determination of CYP3A4 inhibition by CAM in human liver microsomes. After incubation of human liver microsomes with midazolam, liquid–liquid extraction with tert‐butyl methyl ether was applied and dried samples were reconstituted in 50% methanol. These samples were injected onto a reversed‐phase chromatography consisting of a Zorbax Extend‐C18 column (2.1 × 150 mm, 5.0 µm particle size), connected to a triple quadrupole mass spectrometer with electrospray ionization. The described LC‐MS/MS method was validated over linear range of 1.0–500 nm for 1‐hydroxymidazolam. The results revealed good inter‐assay accuracy (≥85% and ≤115%) and within‐day and between‐day precisions (coefficient of variation ≤ 4.43%). Furthermore, the applicability of this assay for the determination of CYP3A4 inhibition in complex matrix mixtures was successfully demonstrated in an in vitro experiment in which CYP3A4 inhibition by known CAM (β‐carotene, green tea, milk thistle and St. John's wort) was determined. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
On‐line solid‐phase extraction (SPE) for pre‐concentration and sample cleanup is one strategy to reduce matrix effects and to simultaneously improve detection sensitivity in liquid chromatography/mass spectrometry (LC/MS). This paper describes an on‐line SPE‐LC/MS method for the determination of tributyltin (TBT) and triphenyltin (TPhT) at trace levels in water samples. The direct coupling of an on‐line C18 pre‐column to LC/MS was used to pre‐concentrate TBT and TPhT at trace levels from waters and to remove interfering matrix effects. Pre‐concentration was followed by separation of TBT and TPhT on a C18 column using a mobile phase containing 0.1% (v/v) HCOOH/5 mM HCOONH4 and methanol. While both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) can be interfaced with MS for the detection of TBT and TPhT, ESI‐MS was preferred for this application. The calibration curve for the targets was linear in the concentration range 0.1–30 µg L?1. The detection limit (signal‐to‐noise (S/N) ratio = 3) was 0.02 µg L?1 when 3.0 mL of sample was enriched on the C18 pre‐column. The recoveries of TBT and TPhT in spiked waters were from 81.0 to 101.9%. The reproducibilities for the analysis of the standard mixture (10 µg L?1) for TBT and TPhT were 13.1 and 5.0%, respectively. The developed method was an easy and fast way to analyze TBT and TPhT in water samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
In this study, a specific and sensitive LC–MS/MS method for the simultaneous analysis of type‐B trichothecenes (deoxynivalenol, 3‐acetyldeoxynivalenol, and 15‐acetyldeoxynivalenol) and the de‐epoxy metabolite of deoxynivalenol (de‐epoxy‐deoxynivalenol) in chicken muscle, liver, kidney, and fat tissues was developed and validated. The method involved an extraction step using ethyl acetate, followed by the evaporation of the supernatant, which was further purified by an Oasis HLB SPE cartridge (Waters, Milford, MA, USA). Chromatographic separation was performed on a C18 column by detection with MS in multiple‐reaction monitoring mode and using a gradient elution program with 0.1% formic acid in water and methanol. The correlation coefficients (r) for each calibration curve were >0.99 within the experimental concentration range. The extraction recoveries ranged from 73.7 to 106.4%, with intraday and interday RSD < 11.6% at three levels of concentrations of 2, 10, and 100 μg/kg. The decision limits and the detection capabilities of the analytes in the chicken tissues ranged from 0.16 to 0.92 and 0.68 to 2.07 μg/kg, respectively. The results demonstrated the applicability of this sensitive procedure to the determination of trichothecenes in chicken tissue samples.  相似文献   

18.
A simple, sensitive and specific high‐performance liquid chromatography mass spectrometry (LC‐MS/MS) method was developed and validated for the quantification of β‐hydroxy‐β‐methyl butyrate (HMB) in small volumes of rat plasma using warfarin as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple reaction‐monitoring mode using the electrospray ionization technique. A simple liquid–liquid extraction process was used to extract HMB and IS from rat plasma. The total run time was 3 min and the elution of HMB and IS occurred at 1.48 and 1.75 min respectively; this was achieved with a mobile phase consisting of 0.1% formic acid in a water–acetonitrile mixture (15:85, v/v) at a flow rate of 1.0 mL/min on a Agilent Eclipse XDB C8 (150 × 4.6, 5 µm) column. The developed method was validated in rat plasma with a lower limit of quantitation of 30.0 ng/mL for HMB. A linear response function was established for the range of concentrations 30–4600 ng/mL (r > 0.998) for HMB. The intra‐ and inter‐day precision values for HMB were acceptable as per Food and Drug Administration guidelines. HMB was stable in the battery of stability studies, viz. bench‐top, autosampler freeze–thaw cycles and long‐term stability for 30 days in plasma. The developed assay method was applied to a bioavailability study in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
A speedy and selective ultra‐HPLC‐MS/MS method for simultaneous determination of deoxynivalenol (DON), 3‐acetyldeoxynivalenol (3‐ADON), 15‐ADON, nivalenol and fusarenon X in traditional Chinese medicines (TCMs) was developed. The method was based on one‐step sample cleanup using reliable homemade cleanup cartridges. A linear gradient mobile‐phase system, consisting of water containing 0.2% aqueous ammonia and acetonitrile/methanol (90:10, v/v) at a flow rate of 0.4 mL/min, and an Acquity UPLC HSS T3 column (100 mm×2.1 mm, 1.8 μm) were employed to obtain the best resolution of the target analytes. [13C15]–DON was used as the internal standard to accomplish as accurate as possible quantitation. The established method was further validated by determining the linearity (R2≥0.9990), sensitivity (LOQ, 0.29–0.99 μg/kg), recovery (88.5–119.5%) and precision (RSD≤15.8%). It was shown to be a suitable method for simultaneous determination of DON, 3‐ADON, 15‐ADON, nivalenol and fusarenon X in various TCM matrices. The utility and practical impact of the method was demonstrated using different TCM samples.  相似文献   

20.
A new paratert‐butylcalix[4]arene column containing thiadiazole functional groups was prepared and used for the separation of polycyclic aromatic hydrocarbons, phenolic compounds, aromatic amines, benzoic acid and its derivatives by high‐performance liquid chromatography (HPLC). The effect of organic modifier content in the mobile phase on retention and selectivity of these compounds were investigated. The results indicate that the stationary phase behaves like reversed‐phase packing. However, hydrogen bonding, π–π and inclusion interactions seem to be involved in the separation process. The column has been successfully employed for the analysis of clenbuterol in pork and pig casing; the limit of detection and the limit of quantitation for this method by HPLC‐UV detection was 0.03 and 0.097 μg/mL, respectively; the method is demonstrated to be suitable and a competitive alternative analytical method for the determination of clenbuterol.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号