共查询到20条相似文献,搜索用时 15 毫秒
1.
Yun‐Yun Yang You‐Zhi Tang Chun‐Lin Fan Hui‐Tai Luo Peng‐Ran Guo Jian‐Xin Chen 《Journal of separation science》2010,33(13):1933-1945
A method based on accelerated solvent extraction combined with rapid‐resolution LC–MS for efficient extraction, rapid separation, online identification and accurate determination of the saikosaponins (SSs) in Radix bupleuri (RB) was developed. The RB samples were extracted by accelerated solvent extraction using 70% aqueous ethanol v/v as solvent, at a temperature of 120°C and pressure of 100 bar, with 10 min of static extraction time and three extraction cycles. Rapid‐resolution LC separation was performed by using a C18 column at gradient elution of water (containing 0.5% formic acid) and acetonitrile, and the major constituents were well separated within 20 min. A TOF‐MS and an IT‐MS were used for online identification of the major constituents, and 27 SSs were identified or tentatively identified. Five major bioactive SSs (SSa, SSc, SSd, 6″‐O‐acetyl‐SSa and 6″‐O‐acetyl‐SSd) with obvious peak areas and good resolution were chosen as benchmark substances, and a triple quadrupole MS operating in multiple‐reaction monitoring mode was used for their quantitative analysis. A total of 16 RB samples from different regions of China were analyzed. The results indicated that the method was rapid, efficient, accurate and suitable for use in the quality control of RB. 相似文献
2.
A rapid and sensitive LC-MS/MS method was developed for the quantitative determination of sucrose esters (SEs) in Oriental tobacco samples. The sample preparation involved a 10-min sonication extraction procedure with acetone and five-fold dilution of the extract with methanol. The experiment was carried out in positive ion mode by ESI IT mass spectrometer. Because of lack of authentic standards of SEs, sucrose octa-acetate (internal standard, IS) was used as a surrogate to validate the proposed method. Matrix-matched standard calibration was used for quantification of IS in the spiked samples. Under optimized MS/MS conditions, an LOQ of 3.9 microg/g was achieved for IS, with an LOD of about 1.2 microg/g. Recoveries for IS were 95-97%. Among 19 monitored SEs, the contents of 11 SEs had RSDs lower than 13.7%. The method, with very little sample handling and good sensitivity, was applied to the rapid quantification of SEs in four Oriental tobacco samples. It appears that the sum of contents of the five SEs with MW 650, 664, and 678 Da occupied approximately 80% of the total content of SEs. 相似文献
3.
Nording M Nichkova M Spinnel E Persson Y Gee SJ Hammock BD Haglund P 《Analytical and bioanalytical chemistry》2006,385(2):357-366
Since soils at industrial sites might be heavily contaminated with polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs), there is a need for large-scale soil pollution surveys and, thus,
for cost-efficient, high-throughput dioxin analyses. However, trace analysis of dioxins in complex matrices requires exhaustive
extraction, extensive cleanup, and very sensitive detection methods. Traditionally, this has involved the use of Soxhlet extraction
and multistep column cleanup, followed by gas chromatography—high-resolution mass spectrometry (GC/HRMS), but bioanalytical
techniques may allow much more rapid, cost-effective screening. The study presented here explores the possibility of replacing
the conventional method with a novel approach based on simultaneous accelerated solvent extraction (ASE) and purification,
followed by an enzyme-linked immunosorbent assay (ELISA). Both the traditional and the novel cleanup and detection approaches
were applied to contaminated soil samples, and the results were compared. ELISA and GC/HRMS results for Soxhlet-extracted
samples were linearly correlated, although the ELISA method slightly underestimated the dioxin levels. To avoid an unacceptable
rate of false-negative results, the use of a safety factor is recommended. It was also noted that the relative abundance of
the PCDDs/PCDFs, evaluated by principal component analysis, had an impact on the ELISA performance. To minimize this effect,
the results may be corrected for differences between the ELISA cross-reactivities and the corresponding toxic equivalency
factor values. Finally, the GC/HRMS and ELISA results obtained following the two sample preparation methods agreed well; and
the ELISA and GC/HRMS results for ASE extracts were strongly correlated (correlation coefficient, 0.90). Hence, the ASE procedure
combined with ELISA analysis appears to be an efficient approach for high-throughput screening of PCDD-/PCDF-contaminated
soil samples.
相似文献
4.
Jianbing Wu Linyao Chen Peipei Mao Yanbin Lu Huizhong Wang 《Journal of separation science》2012,35(24):3586-3592
An effective analytical protocol using graphene‐based SPE coupled with HPLC‐MS/MS for determination of chloramphenicol (CAP) in aquatic products has been developed. In the present work, graphene was evaluated as SPE sorbents for the analytes enrichment and clean up. The target analytes were quantified by a triple‐quadrupole linear ion trap MS in multiple‐reaction monitoring mode. In addition, the proposed method was validated according to Commission Decision 2002/657/EC. The calibration curve was linear over the range of 0.5–100 ng/mL. The mean values of RSD of intra‐ and interday ranging from 1.48 to 4.29% and from 3.25 to 7.42% were obtained, respectively. In the three fortified levels, the recoveries of CAP ranging from 92.3 to 103.4% with RSDs ≤ 5.58% were obtained. The proposed method has been successfully applied to the analysis of CAP in several aquatic product samples, indicating that graphene was a potential SPE sorbent for the enrichment of trace residues in food samples. 相似文献
5.
In this study, a simple, rapid and sensitive method for the determination of five phthalates including dimethyl phthalate, diethyl phthalate, dipropyl phthalate, benzyl butyl phthalate, and dicyclohexyl phthalate in fruit jellies by LC coupled with MS has been developed. Samples were pretreated by a dispersive SPE method, termed QuEChERS, which is an acronym for quick, easy, cheap, effective, rugged, and safe. The standard calibration curves were linear for all the analytes over the concentration range of 10–250 ng/mL, and the correlation coefficients ranged from 0.9976 to 0.9991. The LODs and LOQs were in the ranges of 0.09–3.68 ng/mL and 0.28–11.25 ng/mL, respectively. The accuracy of this method was evaluated by measuring the recovery from spiked samples. The recoveries of all five phthalates from samples spiked at three different concentrations (0.01, 0.03, and 0.05 mg/kg), were in the ranges of 83.5–103.9%, 86.7–95.8%, and 87.1–95.2%, respectively. The RSD values for the samples spiked at 0.01, 0.03 , and 0.05 mg/kg ranged from 2.0–7.6%, 1.4–6.4%, and 1.2–3.8%, respectively. The method has been used for the analysis of real samples and BBP and DEP were found in real samples. 相似文献
6.
Huiyong Wang Nicholas Johnson Jeffrey Bernardy Terry Hubert Weiming Li 《Journal of separation science》2013,36(9-10):1612-1620
Pheromones guide adult sea lamprey (Petromyzon marinus) to suitable spawning streams and mates, and therefore, when quantified, can be used to assess population size and guide management. Here, we present an efficient sample preparation method where 100 mL of river water was spiked with deuterated pheromone as an internal standard and underwent rapid field‐based SPE and elution in the field. The combination of field extraction with laboratory UPLC‐MS/MS reduced the sample consumption from 1 to 0.1 L, decreased the sample process time from more than 1 h to 10 min, and increased the precision and accuracy. The sensitivity was improved more than one order of magnitude compared with the previous method. The influences of experimental conditions were assessed to optimize the separation and peak shapes. The analytical method has been validated by studies of stability, selectivity, precision, and linearity and by the determination of the limits of detection and quantification. The method was used to quantify pheromone concentration from five streams tributary to Lake Ontario and to estimate that the environmental half‐life of 3kPZS is about 26 h. 相似文献
7.
Rapid determination of trace polycyclic aromatic hydrocarbons in particulate matter using accelerated solvent extraction followed by ultra high performance liquid chromatography with fluorescence detection 下载免费PDF全文
Tianci Xu 《Journal of separation science》2016,39(10):1892-1899
A method has been developed for the trace analysis of polycyclic aromatic hydrocarbons, which are known as persistent organic pollutants and ubiquitous constituents of fine particulate matter that causes growing airborne pollution. The method, which was especially for samples of airborne particulate matter less than 2.5 μm in diameter, utilized accelerated solvent extraction and ultra high performance liquid chromatography with fluorescence detector. Four principal parameters of accelerated solvent extraction were optimized to obtain maximum extraction efficiency. Using the established synergetic programs of gradient elution and fluorescence wavelength switching, a rapid separation was achieved in 6.56 min with good linearity for 15 polycyclic aromatic hydrocarbons (coefficient of determination above 0.999). The limits of detection ranged from 0.833 to 10.0 pg/m3. The precision of the method expressed as inter‐day relative standard deviation ranged from 0.2 to 1%, which was calculated from nine repetitive measurements of 8.00 μg/L analytes. Average spiked recoveries ranged from 71.6 to 97.7%, with the exception of naphthalene. The rapid, sensitive, and accurate method can meet the pressing needs of health risk assessment and increasingly heavy daily tasks of air quality monitoring. 相似文献
8.
Integration of normal-phase LC (NPLC) fractionation with RPLC-ESI/MS was established to detect the polar fractions of cuticular components from Oriental tobacco leaf. NPLC was selected for the fractionation of polar components of cuticular leaf extract, after being concentrated with rotary evaporator, each of the enriched fractions was further analyzed by RPLC-ESI/MS. In total, 83 compounds were finally detected including 45 cembranoids, 15 labdanoids, 20 sucrose esters, and 3 glucose esters (or fructose esters). Three cembranoids and seven labdanoids possibly are new diterpenoids. Glucose esters (or fructose esters) are also reported in Nicotiana tobacco for the first time. 相似文献
9.
《Biomedical chromatography : BMC》2018,32(5)
A high‐performance liquid chromatographic (HPLC) method with integrated solid‐phase extraction for the determination of 1‐hydroxypyrene and 1‐, 2‐, 3‐, 4‐ and 9‐hydroxyphenanthrene in urine was developed and validated. After enzymatic treatment and centrifugation of 500 μL urine, 100 μL of the sample was directly injected into the HPLC system. Integrated solid‐phase extraction was performed on a selective, copper phthalocyanine modified packing material. Subsequent chromatographic separation was achieved on a pentafluorophenyl core–shell column using a methanol gradient. For quantification, time‐programmed fluorescence detection was used. Matrix‐dependent recoveries were between 94.8 and 102.4%, repeatability and reproducibility ranged from 2.2 to 17.9% and detection limits lay between 2.6 and 13.6 ng/L urine. A set of 16 samples from normally exposed adults was analyzed using this HPLC‐fluorescence detection method. Results were comparable with those reported in other studies. The chromatographic separation of the method was transferred to an ultra‐high‐performance liquid chromatography pentafluorophenyl core–shell column and coupled to a high‐resolution time‐of‐flight mass spectrometer (HR‐TOF‐MS). The resulting method was used to demonstrate the applicability of LC‐HR‐TOF‐MS for simultaneous target and suspect screening of monohydroxylated polycyclic aromatic hydrocarbons in extracts of urine and particulate matter. 相似文献
10.
快速溶剂萃取-气相色谱-三重四极杆质谱法测定沉积物中的酞酸酯 总被引:5,自引:0,他引:5
建立了快速溶剂萃取(ASE)-气相色谱-三重四极杆质谱(GC-MS/MS)测定沉积物中酞酸酯的方法。样品用二氯甲烷-丙酮(体积比为1:1)混合溶剂在100 ℃、103.4 MPa (1500 psi)条件下经快速溶剂萃取、以5 mL/min的速率经凝胶渗透色谱(GPC)净化去除大分子干扰物后,采用GC-MS/MS分析测定。采用内标法定量,17种酞酸酯的检出限为0.05~0.40 μg/kg;回收率为50.5%~107.9%,相对标准偏差为3.5%~13.9%。采用替代物基体加入法对方法的性能进行了验证,3种替代物的回收率为65.3%~95.8%。该方法快速、灵敏度高,能同时准确定性定量测定17种酞酸酯。 相似文献
11.
Hao Luo Ying‐Kun Nie Yu‐Jie Fu Yuan‐Gang Zu Shuang‐Ming Li Wei Liu Lin Zhang Meng Luo Yu Kong Zheng‐Nan Li 《Journal of separation science》2009,32(2):192-201
A method based on microwave‐assisted extraction (MAE) has been developed for the determination of paclitaxel and five related taxoids, namely 10‐deacetylbaccatin III (10‐DAB III), cephalomannine, 10‐deacetylpaclitaxel (10‐DAT), 7‐xyl‐10‐ deacetylpaclitaxel (7‐xyl‐10‐DAT), and 7‐epi‐10‐deacetylpaclitaxel (7‐epi‐10‐DAT) in Taxus species in this study. The influential parameters of the MAE procedure were optimized, and the optimal conditions were as follows: extraction solvent 80% ethanol solution, solid/liquid ratio 1:10 (g/mL), temperature 50°C, and three extraction cycles, each cycle 10 min. The method validation for LC‐MS/MS analysis was performed. The LOD and LOQ were 3.16–9.20 and 12.20–30.45 ng/mL, respectively. Repeatability and reproducibility for the six taxiods with RSD ranged from 2.78 to 3.85% and from 5.26 to 6.60%. The recoveries of the method for the six taxoids were 92.6–105.6%. The developed MAE‐LC‐MS/MS method was also successfully applied to determine the contents of six taxoids in different Taxus species. 相似文献
12.
Inmaculada C. Rodríguez‐Medina Raúl Beltrán‐Debón Vicente Micol Molina Carlos Alonso‐Villaverde Jorge Joven Javier A. Menéndez Antonio Segura‐Carretero Alberto Fernández‐Gutiérrez 《Journal of separation science》2009,32(20):3441-3448
The phenolic fraction and other polar compounds of the Hibiscus sabdariffa were separated and identified by HPLC with diode array detection coupled to electrospray TOF and IT tandem MS (DAD‐HPLC‐ESI‐TOF‐MS and IT‐MS). The H. sabdariffa aqueous extract was filtered and directly injected into the LC system. The analysis of the compounds was carried out by RP HPLC coupled to DAD and TOF‐MS in order to obtain molecular formula and exact mass. Posterior analyses with IT‐MS were performed and the fragmentation pattern and confirmation of the structures were achieved. The H. sabdariffa samples were successfully analyzed in positive and negative ionization modes with two optimized linear gradients. In positive mode, the two most representative anthocyanins and other compounds were identified whereas the phenolic fraction, hydroxycitric acid and its lactone were identified using the negative ionization mode. 相似文献
13.
A simple and reliable LC‐ESI‐MS method for the determination of peimine and peiminine in rat plasma was developed for the first time. The method was proven to be specific and sensitive by carrying out validation. The analytes were extracted from rat plasma via solid‐phase extraction on Waters Oasis MCX cartridges. Chromatography separation was achieved on a C18 column using 10 mM ammonium acetate (adjusted to pH 3.0 with glacial acetic acid)–acetonitrile (85:15, v/v) as mobile phase. The linear range was 1–100 ng/mL for peimine and peiminine. Intra‐ and inter‐day precisiond were less than 10%. Accuracies were within 85–115% of their nominal concentrations. The limit of quantification was 1 ng/mL for both analytes. The developed assay was successfully applied to pharmacokinetic study of peimine and peiminine in rats orally administered the alkaloids extracts from Bulbus Fritillariae, demonstrating a possible broader spectrum of applications of this method. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
14.
Aili Liu Chao Han Xiujin Zhou Zhenou Zhu Fuzhen Huang Yan Shen 《Journal of separation science》2013,36(5):857-862
A new method based on pressurized liquid extraction followed by LC‐MS/MS analysis has been developed for the identification and quantification of three capsaicinoids (capsaicin, dihydrocapsaicin, and nordihydrocapsaicin) in extracts of Capsicum annuum. For the recovery of three capsaicinoids, the efficiency levels of ultrasonic‐assisted extraction, microwave‐assisted extraction, Soxhlet extraction, and pressurized liquid extraction were compared under different conditions. Pressurized liquid extraction resulted in higher yields. Pressurized liquid extractions were performed using methanol; temperature was set at 100°C and pressure at 1500 psi. LC analysis was performed on a Waters XBridge? C18 column (150 × 2.1 mm, id 3.5 μm) eluted by a mobile phase of 0.1% formic acid and ACN. Data acquisition was carried out in multiple reaction monitoring transitions mode, monitoring two‐reaction monitoring transitions to ensure an accurate identification of target compounds in the samples. The proposed method is rapid, simple, and could be utilized for the routine analysis of three capsaicinoids in C. annuum samples. 相似文献
15.
The high surface area monolith with reactive hydroxyl group on its surface enables it to function as a miniature solid‐phase extraction (SPE) cartridge in size of 1 cm in diameter and 0.5 cm in length. The prepared silica monolith was characterized by Brunauer–Emmett–Teller method, scanning electron microscopy, X‐ray diffraction and Fourier transform infrared (FTIR) spectroscopy. Ketamine was selected as model analyte to validate the extraction efficiency of the prepared cartridge. The extracted ketamine from urine sample was quantitated by liquid chromatography tandem mass spectrometry (LC‐MS/MS) using positive electrospray ionization. The limit of detection and quantification for ketamine was found to be 0.5 and 1.6 ng/mL, respectively. The analysis exhibited linearity in the range of 10–500 ng/mL with coefficient of correlation >0.99. The recovery was found to be in the range of 89–107% with relative standard deviation (RSD) less than 10%. The prepared cartridge was found robust in extracting ketamine efficiently and repeatedly without any significant deterioration in its performance. Moreover, the batch‐to‐batch variations in the performance of the prepared cartridges in terms of % ion suppression of the extracts and recoveries of samples were small, suggesting the consistency in the properties of the monolith. 相似文献
16.
《Journal of separation science》2005,28(13):1485-1492
SPE is a commonly applied technique for preconcentration of pesticides from water samples. Microwave‐assisted extraction (MAE) technique is the extraction applied for preconcentration of different compounds from solid samples. SPE coupled with MAE is capable of preconcentrating these compounds from water samples too. This investigation was aimed at improving the efficiency of atrazine, alachlor, and α‐cypermethrin pesticide extraction from the spiked water samples applying SPE followed by MAE. In this way, MAE served for elution of pesticides from C18‐extraction disks with solvent heated by microwave energy. Various elution conditions were tested for their effects on the extraction efficiency of the SPE–MAE combined technique. Several parameters, such as elution solvent volume (mL), elution temperature (°C), and duration of elution (min), affect the extraction efficiency of the SPE–MAE coupled system and need to be optimized for the selected pesticides. In order to develop a mathematical model, 15 experiments were performed in the central composite design. The equation was then used to predict recoveries of the pesticides under specific experimental conditions. Optimization of microwave extraction was accomplished using the genetic algorithm approach. Best results were achieved using 20 mL of ethanol at 60°C. Optimal hold time was 5 min and 24 s. The SPE–MAE combination was also compared with the conventional SPE extraction technique with elution of a nonpolar or a moderately polar compound with nonpolar solvents. 相似文献
17.
Yunfei Sha Jiaoran Meng Yichun Zhang Chunhui Deng Da Wu 《Journal of separation science》2010,33(2):212-217
In this work, the novel technique based on headspace single‐drop microextraction with in‐syringe derivatization followed by GC‐MS was established to determine the volatile organic acids in tobacco. The parameters for headspace single‐drop microextraction and in‐syringe derivatization were optimized, including extraction time, and volume of derivatization reagent and in‐syringe derivatization time. The method validations including linearity, precision, recovery and LOD were also studied. The obtained results illustrated that the optimized technique was easy, highly efficient and sensitive. Finally, the proposed method was successfully applied to the analyses of volatile organic acids in tobacco samples with seven different brands. It was further demonstrated that the present technique developed in this study does offer a simple and fast approach to determine volatile organic acids in tobacco. 相似文献
18.
Laura Vallecillos Francesc Borrull Eva Pocurull 《Journal of separation science》2012,35(20):2735-2742
A method for the quantitative determination of ten musk fragrances extensively used in personal care products from sewage sludge was developed by using a pressurized liquid extraction (PLE) followed by an automated ionic liquid‐based headspace single‐drop microextraction and gas chromatography‐tandem mass spectrometry. The influence of main factors on the efficiency of PLE was studied. For all musks, the highest recovery values were achieved using 1 g of pretreated sewage sludge, H2O/methanol (1:1) as an extraction solvent, a temperature of 80°C, a pressure of 1500 psi, an extraction time of 5 min, 2 cycles, a 100% flush volume, a purge time of 120 s, and 1 g Florisil as in‐cell clean‐up extraction sorbent. The use and optimization of an in‐cell clean‐up sorbent was necessary to remove fatty interferents of the PLE extract that make the subsequent ionic liquid‐based headspace single‐drop microextraction difficult. Validation parameters, namely LODs and LOQs, ranged from 0.5–1.5 to 2.5–5 ng/g, respectively. Good levels of intra‐ and interday repeatabilities were obtained analyzing sewage sludge samples spiked at 10 ng/g (n = 3, RSDs < 10%). The method applicability was tested with sewage sludge from different wastewater treatment plants. The analysis revealed the presence of all the polycyclic musks studied at concentrations higher than the LOQs, ranging from 6 to 530 ng/g. However, the nitro musk concentrations were below the LOQs or, in the case of musk xylene, was not detected. 相似文献
19.
A consecutive preparation method based upon accelerated solvent extraction (ASE) coupled with high‐speed counter‐current chromatography (HSCCC) was presented and aesculin was obtained from Cortex fraxinus. The extraction condition of ASE was optimized with response surface methodology; some significant parameters such as the solvent system and its stability, the amount of loading sample in HSCCC were also investigated. The original sample was first extracted with methanol at 105°C and 104 bar for 7 min using ASE, then the extracts were consecutively introduced into the HSCCC system and separated and purified with the same ethyl acetate/n‐butanol/water (7:3:10, v/v/v) solvent system for five times without further exchange and equilibrium. About 3.1 ± 0.2 mg/g in each time and total of 15.4 mg/g aesculin with purity over 95% was isolated from Cortex fraxinus. The results demonstrated that the consecutive preparation method was time and solvent saving and high throughput, it was suitable for isolation of aesculin from Cortex fraxinus, and also has good potential on the separation and purification of effective compounds from natural product. 相似文献
20.
《Biomedical chromatography : BMC》2018,32(9)
A bioanalytical method was developed and validated for the quantification of capreomycin (Cm) analogs, Cm IA and Cm IB, in human plasma. This implemented ion‐pairing solid phase extraction, followed by ion‐pairing high‐performance liquid chromatography, with tandem mass spectrometry detection. Chromatographic separation was achieved using a Discovery C18, 5 μm, 4.6 × 50 mm analytical column. An isocratic mobile phase consisting of water and acetonitrile with 0.1% formic acid and 4mm heptafluorobutyric acid (80:20; v/v) was used at a flow‐rate of 500 μL/min. An AB Sciex API 3000 mass spectrometer at unit resolution, in multiple reaction monitoring mode, was used for detection. Electrospray ionization was used for ion production. The method was successfully validated for the range 469–30,000 ng/mL for Cm IA and for Cm IB, with cefotaxime as the internal standard. The within‐ and between‐day precision determinations for Cm IA and IB, expressed as the percentage coefficient of variation, were < 20.0% at the lower limit of quantification (LLOQ) and < 8.2% at all other test concentrations. Recovery of both analogs was > 72.3% and reproducible at the low, medium and high end of the calibration range. No significant matrix effects were observed for the analyte. The assay performed well when applied to clinical samples generated from children in a clinical multidrug resistant tuberculosis research study in South Africa. 相似文献