首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and effective micellar electrokinetic capillary chromatography with laser‐induced fluorescence detection approach was described for the determination of low molecular‐mass thiols using 1,3,5,7‐tetramethyl‐8‐phenyl‐(4‐iodoacetamido) difluoroboradiaza‐s‐indacene as the labeling reagent. After precolumn derivatization, baseline separation of six thiol compounds including cysteine, glutathione, N‐acetylcysteine, homocysteine, 6‐mercaptopurine, and penicillamine were achieved within 18 min. The optimal running buffer was composed of mixtures involving 25 mM sodium dodecyl sulfate, 25% (v/v) acetonitrile and 15 mM sodium phosphate buffer, pH 7.5. The detection limits (S/N = 3) were found as low as 40 pM under argon ion laser‐induced fluorescence detector (λex/λem = 488/520 nm), which were much better than the reported approaches. The accuracy and specificity of this assay for real samples were assured by a standard addition method. The proposed method has been applied to the analysis of thiols both in human plasma and plum flower samples with recoveries of 92.0–109.4%.  相似文献   

2.
This paper, for the first time, reported the development of a simple, rapid, and reliable method for the separation and sensitive determination of four thiol compounds including homocysteine, cysteine, glutathione, and N‐acetylcysteine based on glass MCE with fluorescence detection using a highly reactive fluorogenic probe, 1,3,5,7‐tetramethyl‐8‐phenyl‐(2‐maleimide)‐difluoroboradiaza‐s‐indacene (TMPAB‐o‐M), as the labeling reagent. TMPAB‐o‐M reacted selectively with thiols to produce highly fluorescent derivatives and the highest derivatization efficiency was achieved within 6 min in physiological conditions. After the optimization of separation conditions, a baseline separation of the four thiol compounds was achieved with the detection limits ranging from 2 nM for glutathione to 4 nM for cysteine (S/N = 3) and RSDs (n = 5) in the range of 3.2–3.8%. The proposed method was significantly sensitive compared to those using electrochemical or even LIF detection in MCE‐based setup reported previously, and applied to the determination of intracellular thiols in macrophage RAW264.7 cells.  相似文献   

3.
A CZE with near‐infrared (NIR) LIF detection method has been developed for the analysis of six low molecular weight thiols including glutathione, homocysteine, cysteine, γ‐glutamylcysteine, cysteinylglycine, and N‐acetylcysteine. For this purpose, a new NIR fluorescent probe, 1,7‐dimethyl‐3,5‐distyryl‐8‐phenyl‐(4'‐iodoacetamido)difluoroboradiaza‐s‐indacene was utilized as the labeling reagent, whose excitation wavelength matches the commercially available NIR laser line of 635 nm. The optimum procedure included a derivatization step of the free thiols at 45°C for 25 min and CZE analysis conducted within 14 min in the running buffer containing 16 mmol/L pH 7.0 sodium citrate and 60% v/v ACN. The LODs (S/N = 3) ranged from 0.11 nmol/L for N‐acetylcysteine to 0.31 nmol/L for γ‐glutamylcysteine, which are better than or comparable to those reported with other derivatization‐based CE‐LIF methods. As the first trial of NIR CE‐LIF method for thiol determination, the practical application of the proposed method has been validated by detecting thiols in cucumber and tomato samples with recoveries of 96.5–104.3%.  相似文献   

4.
A rapid and robust CE method using a long wavelength fluorescent reagent 1,7‐dimethyl‐3,5‐distyryl‐8‐phenyl‐(2‐maleimide)difluoroboradiaza‐s‐indacene as the labeling reagent has been developed for the simultaneous determination of thiols, including glutathione, cysteine, homocysteine, N‐acetylcysteine, cysteinylglycine, and penicillamine. The derivatization reaction was carried out in 14 mmol/L pH 8.5 borate buffer at 30°C for 6 min and the labeled thiols derivatives were separated with the running buffer containing 30 mmol/L pH 7.4 phosphate, 30% v/v acetonitrile and 8 mmol/L SDS within 12 min. Detection limits ranged from 0.4 to 2.4 nmol/L. To demonstrate the capability of this method, it was applied to the analysis of thiols in human urine with recoveries of 92.4–105.6%. The derivatization reaction was much faster at milder conditions, and the analysis was rapider. Moreover, with excitation wavelength at long wavelength region, background interference from samples was reduced effectively. The present method seems to be a potential choice for quantifying thiols in human urine.  相似文献   

5.
We have developed a simple, fast, accurate, and cheap method for the simultaneous determination of total cysteine, homocysteine, glutathione, and N‐acetylcysteine in brain homogenates based on the reduction of disulfide bonds by tris(2‐carboxyethyl) phosphine, pre‐column derivatization of free thiol groups with 2‐chloro‐1‐methylquinolinium tetrafluoroborate followed by ion‐pair reversed‐phase high‐performance liquid chromatography separation with ultraviolet detection. The separation of thiol derivatives was achieved in 10 min. Linearity was observed in the range of 10–300, 0.7–10, 2–30, and 3–20 μmol/L homogenate with a limit of detection of 3.7, 0.2, 0.8, and 1.2 μmol/L homogenate for cysteine, homocysteine, glutathione, and N‐acetylcysteine, respectively. The precision, calculated as relative standard deviation, was in the range of 1.21–4.77, 1.53–14.35, 0.47–1.92, and 1.61–8.95% for cysteine, homocysteine, glutathione, and N‐acetylcysteine, respectively. The presented method was successfully applied to the selective determination of total amino thiols in pig brain tissue samples.  相似文献   

6.
《Electrophoresis》2017,38(3-4):494-500
An easy‐to‐do paper‐based solid‐phase microextraction (p‐SPME) was developed for determination of 8‐hydroxy‐2’‐deoxyguanosine (8‐OHdG) in urine sample by CE‐LIF. Small piece of filter paper was used as a solid phase to extract 8‐OHdG from urine sample. Its primary mechanism is based on the hydrogen‐bonding interaction between 8‐OHdG and cellulose molecules. The effects of the pH of the sample solution, extraction time, and temperature on the peak area of the analyte were investigated in order to obtain the optimal p‐SPME conditions. Comparing with the untreated sample, the p‐SPME can significantly reduce the interference to the separation of 8‐OHdG by CE‐LIF. Meanwhile, the p‐SPEM can provide more than three times concentrated effect. The developed method was evaluated according to an FDA guideline for biological analysis. The precisions (RSD%, n = 5) of the peak area and migration time of the analyte at three different concentrations were within 3.02–5.82% and 0.92–1.58%, respectively. The limit of identification of the method is about 5 nM according to the significant difference between two sets of the samples with and without spiking the standard (Student's t ‐test, p < 0.05). Good linearity was obtained in the range of 10–1000 nM (R 2>0.99) based on the standard addition. The recoveries at three different concentrations were within 99.8–103.5%. The results of the real sample analysis are consistent with those reported in our previous paper (Electrophoresis 2014, 35, 1873–1879).  相似文献   

7.
Precolumn derivatization of six short‐chain aliphatic amines by a near‐infrared dye, 1‐(ε‐succinimydyl‐hexanoate)‐1′‐methyl‐3,3,3′,3′‐tetramethyl‐indocarbocyanine‐5,5′‐ disulfonate potassium (MeCy5‐OSu), followed by MEKC–CE–LIF detection has been developed as a method for the determination of aliphatic amines in environmental water and food. Optimum derivatization was operated nicely in pH 9.0 borate buffer at 20°C for 30 min. Well separated peaks were observed with a pH 9.5 BGE containing 10 mmol L?1 phosphoric acid, 20 mmol L?1 SDS, and 7% methanol buffered with 1.0 mol L?1 NaOH. The separation procedure was rapidly achieved within 11 min and the matrix interferences could be effectively eliminated. A linear calibration graph was obtained for 5–200 nmol L?1 analytes with a correlation coefficient in the range 0.9933–0.9995 for amines. This method was successfully utilized to determine aliphatic amines in lake, sewage water, and red wine with recoveries ranging from 96.4 to 105% and the RSDs ranging from 0.9 to 2.9%. Near‐infrared, LIF‐detector‐compatible MeCy5‐OSu was proved suitable for the accurate, sensitive, and rapid separation and determination of aliphatic amines in water and food samples.  相似文献   

8.
A rapid, sensitive, and selective precolumn derivatization method for the simultaneous determination of eight thiophenols using 3‐(2‐bromoacetamido)‐N‐(9‐ethyl‐9H )‐carbazol as a labeling reagent by high‐performance liquid chromatography with fluorescence detection has been developed. The labeling reagent reacted with thiophenols at 50°C for 50 min in aqueous acetonitrile in the presence of borate buffer (0.10 mol/L, pH 11.2) to give high yields of thiophenol derivatives. The derivatives were identified by online postcolumn mass spectrometry. The collision‐induced dissociation spectra for thiophenol derivatives gave the corresponding specific fragment ions at m/z 251.3, 223.3, 210.9, 195.8, and 181.9. At the same time, derivatives exhibited intense fluorescence with an excitation maximum at λex = 276 nm and an emission maximum at λem = 385 nm. Excellent linear responses were observed for all analytes over the range of 0.033–6.66 μmol/L with correlation coefficients of more than 0.9997. Detection limits were in the range of 0.94–5.77 μg/L with relative standard deviations of less than 4.54%. The feasibility of derivatization allowed the development of a rapid and highly sensitive method for the quantitative analysis of trace levels of thiophenols from some rubber products. The average recoveries (n = 3) were in the range of 87.21–101.12%.  相似文献   

9.
A new high-performance liquid chromatographic (HPLC) method for measuring low molecular weight (LMW) thiol-containing compounds, including cysteine (CysH), glutathione (GSH), N-acetylcysteine (Nac), penicillamine (PA), and 2-mercaptoethanol (2-ME), has been developed by using 5-methyl-(2-(m-iodoacetylaminophenyl)benzoxazole (MIPBO) as fluorescence-labeling reagent. The derivatization and separation conditions have been investigated in detail. Detection limits ranging from 3.5 to 15.0 fmol were achieved for the thiols investigated in a 16 min separation with detection wavelengths 310 and 375 nm for the excitation and emission, respectively. The utility of the proposed method has been validated by measuring CysH in human urine samples.  相似文献   

10.
《Electroanalysis》2004,16(11):915-921
Voltammetric behavior of two mercaptopyrimidine derivatives (2‐thiouracil and 2‐thiobarbituric acid) has been studied by cyclic voltammetry at a cobalt phthalocyanine (CoPc)‐modified carbon‐paste electrode. The results of voltammetric determinations showed that the CoPc in the matrix of modified electrode acts as catalyst for electrooxidation of these thiols (RSH), lowering the overpotential of the reaction and significantly increasing the sensitivity for detection of thiols in neutral conditions. The results of voltammetric and polarization measurements in solutions with various pHs were used for prediction of the mechanism of electrocatalytic oxidation at the surface of modified electrode. These results showed that at the modified electrode, electrochemical oxidation of thiolate anion (RS?) is the rate‐determining step. It was found that the modified electrode exhibits good selectivity for catalytic oxidation of mercaptopyrimidines over other biologically important mercaptans such as cysteine, glutathione and thioglycolic acid. The results demonstrate that the peak current for thiol oxidation has a linear variation with the concentration in the range of 1×10?2–1×10?5 M. This system can be used for sensitive and selective voltammetric detection of mercaptopyrimidine derivatives.  相似文献   

11.
Quantitative determination of amphetamine in plasma by the use of a novel electrophoric derivatization reagent, o‐(pentafluorobenzyloxycarbonyl)‐2,3,4,5‐tetrafluorobenzoyl chloride is described. Amphetamine can be quantitatively measured down to 49 pg/mL plasma using only 250 μL of sample due to the extraordinary sensitivity of the derivatives under negative ion chemical ionization MS. Plasma samples were made alkaline with carbonate buffer and treated with n‐hexane and reagent solution for 20 min, which, after concentration was measured by negative ion chemical ionization GC‐MS. The method is rapid as extraction and derivatization occur in one single step. [2H5]‐Amphetamine was used as an internal standard. Validation data are given to demonstrate the usefulness of the assay, including specificity, linearity, accuracy and precision, benchtop stability, freeze–thaw stability, autosampler stability, aliquot analysis, and prospective analytical batch size accuracy.  相似文献   

12.
8‐Hydroxy‐2′‐deoxyguanosine (8‐OHdG) detection by high performance liquid chromatography (HPLC) with amperometric detection was studied using a Au electrode modified with different dendrimer based thin films. Gold electrode is thiol‐modified, forming self‐assembled monolayers on which different generation PAMAM dendrimers with terminal functional groups ? COOH and ? NH2 have been attached using peptidic bonds. Results obtained in synthetic samples show low limits of detection and quantification for 8‐OHdG (1.2×10?9 and 3.7×10?9 M respectively), with matrix interference elimination, thus avoiding sample pretreatment. Best results are obtained with electrodes modified with aliphatic amino thiols and 3.5 and 4.5 generation carboxylated dendrimers (Au/AET/DG3.5 and Au/AET/DG4.5), demonstrating that these materials constitute a good alternative for 8‐OHdG determination in biological fluids.  相似文献   

13.
Two efficient methods for the preparation of 2‐(2‐sulfanyl‐4H‐3,1‐benzothiazin‐4‐yl)acetic acid derivatives 3 under mild conditions have been developed. The first method is based on the reaction of 3‐(2‐isothiocyanatophenyl)prop‐2‐enoates 1a – 1c with thiols in the presence of Et3N in THF at room temperature, leading to the corresponding dithiocarbamate intermediates 2 , which underwent spontaneous cyclization at the same temperature by an attack of the S‐atom at the prop‐2‐enoyl moiety in a 1,4‐addition manner (Michael addition) to give 2‐(2‐sulfanyl‐4H‐3,1‐benzothiazin‐4‐yl)acetates in one pot. The second method involves treatment of 3‐(2‐isothiocyanatophenyl)prop‐2‐enoic acid derivatives 1b – 1d with Na2S leading to the formation of 2‐(2‐sodiosulfanyl‐4H‐3,1‐benzothiazin‐4‐yl)acetic acid intermediates 5 by a similar addition/cyclization sequence, which are then allowed to react with alkyl or aryl halides to afford derivatives 3 . 2‐(2‐Thioxo‐4H‐3,1‐benzothiazin‐4‐yl)acetic acid derivatives 6 can be obtained by omitting the addition of halides.  相似文献   

14.
The synthesis of 3‐allyloxymethyl‐3‐ethyloxetane (AllylEHO) and its polymerization with BF3 × Et2O is described in this study. Size exclusion chromatography (SEC) and membrane osmometry are used for the determination of molecular weights of the obtained products, ranging from Mn,SEC = 41,500‐131,500 g/mol. 1H NMR spectroscopy, SEC, as well as MALDI‐TOF MS reveal the formation of cyclic tetramer beside low, but detectable concentrations of larger cyclic oligomers as by‐products during the polymerization process. These results help to understand mechanistically why attempts for a controlled homopolymerization of AllylEHO fail and why a controlled homopolymerization of oxetanes has not been described so far in the literature. Additionally, the high versatility of allyl‐functional polyoxetane for postpolymerization modification is proven by thiol–ene reactions with 3‐mercaptopropionic acid and N‐acetyl‐L ‐cysteine methyl ester. © 2012 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem, 2013  相似文献   

15.
A new and convenient method for the preparation of 2‐aryl‐2,3‐dihydro‐1,8‐naphthyridin‐4(1H)‐ones 4 has been developed. Thus, N‐{3‐[(2E)‐3‐arylprop‐2‐enoyl]pyridin‐2‐yl}‐2,2‐dimethylpropanamides 3 are synthesized from commercially available pyridin‐2‐amine using an easily performed three‐step sequence and are subjected to cyclization with deprotection under acidic conditions in H2O to give the desired products. Similarly, 2‐aryl‐2,3‐dihydro‐1,7‐naphthyridin‐4(1H)‐ones 8 and 2‐aryl‐2,3‐dihydro‐1,6‐naphthyridin‐4(1H)‐ones 12 can be prepared from pyridin‐3‐amine and pyridin‐4‐amine, respectively.  相似文献   

16.
To help to clarify therapeutic functions of lipoic acid (LA) in biochemical and clinical practice we have elaborated a fast, simple and accurate HPLC method enabling determination of LA in human urine. The proposed analytical approach includes reduction of LA with tris(2‐carboxyethyl)phosphine and simultaneous separation and derivatization of the analyte with butylamine and o‐phthaldialdehyde followed by spectrofluorimetric detection at λex = 340 nm and λem = 440 nm. The assay was performed using gradient elution and the mobile phase containing 0.0025 mol L?1 o‐phthaldialdehyde in 0.0025 mol L?1 NaOH and acetonitrile. Linearity of the detector response for LA was observed in the range of 0.3–8 μmol L?1. Limits of detection and quantification for LA in urine samples were 0.02 and 0.03 μmol L?1, respectively. The total analysis time, including sample work‐up, was <20 min. The analytical procedure was successfully applied to analysis of real urine samples delivered from six healthy volunteers who received a single 100 mg dose of LA.  相似文献   

17.
Thin silica gel layers impregnated with optically pure l ‐glutamic acid were used for direct resolution of enantiomers of (±)‐isoxsuprine in their native form. Three chiral derivatizing reagents, based on DFDNB moiety, were synthesized having l ‐alanine, l ‐valine and S‐benzyl‐l ‐cysteine as chiral auxiliaries. These were used to prepare diastereomers under microwave irradiation and conventional heating. The diastereomers were separated by reversed‐phase high‐performance liquid chromatography on a C18 column with detection at 340 nm using gradient elution with mobile phase containing aqueous trifluoroacetic acid and acetonitrile in different compositions and by thin‐layer chromatography (TLC) on reversed phase (RP) C18 plates. Diastereomers prepared with enantiomerically pure (+)‐isoxsuprine were used as standards for the determination of the elution order of diastereomers of (±)‐isoxsuprine. The elution order in the experimental study of RP‐TLC and RP‐HPLC supported the developed optimized structures of diastereomers based on density functional theory. The limit of detection was 0.1–0.09 µg/mL in TLC while it was in the range of 22–23 pg/mL in HPLC and 11–13 ng/mL in RP‐TLC for each enantiomer. The conditions of derivatization and chromatographic separation were optimized. The method was validated for accuracy, precision, limit of detection and limit of quantification. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
《Electroanalysis》2004,16(23):1938-1943
An organically modified sol‐gel glass (ORMOSIL) encapsulating pyrroloquinoline quinone (PQQ)‐modified electrode for the rapid, sensitive and simple determination of thiol‐containing compounds such as cysteine and glutathione is reported. The effect of applied potential, nature of thiol compound and pH on the response of the sensor was examined and optimum conditions were determined. The electrochemical responses and detection limits were found to be sensitive to the nature of thiols and pH. The electrochemical responses for cysteine and glutathione at an applied potential of ?0.2 V (vs. Ag/AgCl) were found to be linear with detection limits of 18 nM for cysteine and 36 nM for glutathione at pH 3.5, whereas the detection limits at pH 8.5 were 0.5 μM for cysteine and 1 μM for glutathione. The electrode retained 95% of the original response for 7 days when stored at 4 °C. The ORMOSIL‐encapsulated PQQ was also characterized by spectrophotometry. The absorbance measurement using 5,5′‐dithiobis(2‐nitrobenzoic acid) at 412 nm justify the PQQ‐mediated oxidation of glutathione whereas fluorescence measurements (excitation wavelength=380 nm; emission wavelength=480 nm) justify the successful encapsulation of PQQ in ORMOSIL matrix.  相似文献   

19.
Conjugated systems based on phospholes and 1,1′‐biphospholes bearing 3,4‐ethylenedithia bridges have been prepared using the Fagan–Nugent route. The mechanism of this organometallic route leading to intermediate zirconacyclopentadienes has been investigated by using theoretical calculations. This study revealed that the oxidative coupling leading to zirconacyclopentadienes is favored over oxidative addition within the S? C≡C bond both thermodynamically and kinetically. The impact of the presence of the S atoms on the optical and electrochemical behavior of the phospholes and 1,1′‐biphospholes has been systematically evaluated both experimentally and theoretically. A comparison with their “all‐carbon” analogues is provided. Of particular interest, this comparative study revealed that the introduction of S atoms has an impact on the electronic properties of phosphole‐based conjugated systems. A decrease of the HOMO–LUMO separation and a stabilization of the LUMO level were observed. These general trends are also observed with 1,1′‐biphospholes exhibiting σ–π conjugation. The P atom of the 3,4‐ethylenedithiaphospholes can be selectively oxidized by S8 or O2. These P modifications result in a lowering of the HOMO–LUMO separation as well as an increase of the reduction and oxidation potentials. The S atoms of the 3,4‐ethylenedithia bridge of the 2,5‐phosphole have been oxidized using m‐chloroperoxybenzoic acid. The resulting 3,4‐ethylenesulfoxide oxophosphole was characterized by an X‐ray diffraction study. Experimental and theoretical studies show that this novel chemical manipulation results in an increase of the HOMO–LUMO separation and an important decrease of the LUMO level. The electropolymerization of 2‐thienyl‐capped 3,4‐ethylenedithiathioxophosphole and 1,1′‐biphosphole is reported. The impact of the S substituents on the polymer properties is discussed.  相似文献   

20.
A sensitive and selective method for the determination of Sb3+ based on the formation of its complexes with 8‐hydroxyquinoline (HQ) and 8‐hydroxyquinoline‐5‐sulfonic acid (HQS) is proposed. The best analytical conditions are: pH 5.4 and 2.2 for HQ and HQS, respectively; CHQ from 15.0 to 25.0 µmol L?1 and CHQS from 70.0 to 200.0 µmol L?1. The detection limits are 100.0 and 14.0 ng L?1 (tacc=30 s) for Sb3+ with HQ and HQS, respectively. The method using HQS as ligand has a 2.2‐fold higher sensitivity than that with HQ and the former was chosen for Sb3+ determination.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号