首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
How to determine the multipesticide residues in vegetables is an important problem. In this study, a new molecularly imprinted polymer was synthesized using O,O‐dimethyl thiophosphoryl chloride, an intermediate for the manufacture of organophosphorous pesticides, as the template. Characterization test indicated that the synthesized polymer exhibited good recognition and selectivity for dichlorvos, methamidophos, acephate, folimat, monocrotophos, parathion‐methyl, phosphamidon, and malathion. A molecularly imprinted SPE coupled to GC for simultaneous separation and determination of eight organophosphorous pesticides residues was developed. Under optimal conditions, the linear range of this method was 0.001–10.0 mg/L. The LOD of this method was in the range of 0.13–0.90 μg/kg. With a flow rate of 2.5 mL/min for loading 100 mL, the enrichment factor in the range of 25–480 for the eight organophosphorous pesticides was obtained. The RSD of the eight organophosphorous pesticides based on five replicates was from 1.50 to 4.09%. The accuracy of the proposed method was evaluated by recovery measurements on spiked samples, and good recovery rates ranging from 80.11 to 97.70% were achieved. Moreover, this method was evaluated for the quantitative detection of eight organophosphorous pesticide residues in leek and pakchoi samples.  相似文献   

2.
A novel flow injection electrochemiluminescence method combined with molecularly imprinted solid‐phase extraction was developed for the determination of L ‐phenylalanine, in which was used as the luminophor and indium tin oxide glass was modified as the working electrode. Molecularly imprinted polymers, synthesized by self‐assembly with functional monomer and crossing linker, were used for the selective extraction of L ‐phenylalanine. In order to overcome the drawbacks of traditional electrochemiluminescence cells such as high IR drop, high over‐potential and so on, a novel electrochemiluminescence cell was developed. The enhanced electrochemiluminescence intensity was linearly related with the concentration of L ‐phenylalanine in the range from 1.0×10?7 to 5.0×10?5 g/mL with a detection limit of 2.59×10?8 g/mL. The relative standard deviation for the determination of 1.0×10?6 g/mL L ‐phenylalanine was 1.2% (n=11). The method showed higher sensitivity and good repeatability, and was successfully applied for the determination of L ‐phenylalanine in egg white, chicken and serum samples. A possible mechanism for the enhanced electrochemiluminescence response on indium tin oxide glass is proposed.  相似文献   

3.
The naturally occurring quercetin flavonoid, dihydroquercetin, is widely distributed in plant tissues and has a variety of biological activities. Herein, a magnetic molecularly imprinted solid‐phase extraction was tailor made for selective determination of dihydroquercetin in Larix griffithiana using high‐performance liquid chromatography. Amino‐functionalized core‐shell magnetic nanoparticles were prepared and characterized using scanning electron microscopy, transmission electron microscopy, vibrating sample magnetometry, and infrared spectroscopy. The polymer had an average diameter of 250 ± 2.56 nm and exhibited good stability and adsorption for template molecule, which is enriched by hydrogen bonding interaction. Multiple factors for extraction, including loading, washing, elution solvents, and extraction time, were optimized. The limit of detection was 1.23 μg/g. The precision determined at various concentration of dihydroquercetin was less than 4% and the mean recovery was between 74.64 and 101.80%. It has therefore been shown that this protocol can be used as an alternative extraction to quantify dihydroquercetin in L. griffithiana and purify quercetin flavonoid from other complex matrices.  相似文献   

4.
A simple, sensitive, and selective molecularly imprinted solid‐phase extraction and spectrophotometric method has been developed for the clean‐up and preconcentration of indapamide from human urine. Molecularly imprinted polymers were prepared by a non‐covalent imprinting approach using indapamide as a template molecule, 2‐(trifluoromethyl) acrylic acid as a functional monomer, ethylene glycol dimethacrylate as a crosslinker, N,N‐azobisisobutyronitrile as a thermal initiator and acetonitrile as a porogenic solvent. A non‐imprinted polymer was also prepared in the same way, but in the absence of template. Molecularly imprinted polymer and non‐imprinted polymer sorbents were dry‐packed into solid‐phase extraction cartridges. Eluates from cartridges were analyzed using a spectrophotometer for the determination of indapamide by referring to the calibration curve in the range 0.14–1.50 μg/mL. Preconcentration factor, limit of detection, and limit of quantification were 16.30, 0.025 μg/mL, and 0.075 μg/mL, respectively. A relatively high imprinting factor (9.3) was also achieved and recovery values for the indapamide spiked into human urine were in the range of 80.1–81.2%. In addition, relatively low within‐day (0.17–0.42%) and between‐day (1.1–1.4%) precision values were obtained as well. The proposed molecularly imprinted solid‐phase extraction and spectrophotometric method was successfully applied to selective extraction, preconcentration, and determination of indapamide from human urine samples.  相似文献   

5.
In the present paper, we describe a new on‐line SPE system where molecular imprinting, fiber‐optic detection and flow injection analysis were combined for the first time. This new system has been applied for the on line detection of 4‐nitrophenol (4‐NP). Initially, molecularly imprinted polymers (MIP) have been prepared for the selective extraction of 4‐NP using 4‐vinylpyridine and ethylene glycol dimethacrylate as functional and cross‐linking monomers, respectively. Selective extraction was achieved using the designed MIP with 97% of recovery on imprinted polymer and 10% on control polymer. The system provided a high degree of accuracy, with RSDs varying between 0.7 and 1.39%. In respect of accuracy, reproducibility, and rapidity, this system is comparable with HPLC. In short, the system allows simple, fast, and accurate analyte determination with the possibility of future automation.  相似文献   

6.
Advanced SPE with molecularly imprinted polymers (MIP) was used in this study. A noncovalent imprinting approach was applied to separate 17β‐estradiol, estriol, and estrone from water samples. Polymer material was prepared by bulk polymerization with methacrylic acid as a functional monomer, divinylbenzene and ethyleneglycol dimethacrylate as crosslinkers, and acetonitrile, acetonitrile/toluene (3:1, v/v) or isooctane/toluene (1:99, v/v) as a porogen. We also prepared an MIP film on a silica gel surface with methacrylic acid and ethyleneglycol dimethacrylate as monomers and acetonitrile as a solvent. Qualitative and quantitative hormone analyses were carried out by HPLC with various detection techniques, including UV/visible spectroscopic detection (diode array detection) and electrochemical detection (CoulArray). The results of the study indicate that MIP technology is an excellent method for the quality control of estrogens in environmental analyses with a low quantification limit for 17β‐estradiol of around 26 (diode array detection) and 0.25 ng/mL (electrochemical detection). The proposed method was found to be suitable for routine determinations of the analyzed compound in environmental laboratories.  相似文献   

7.
A class‐specific macrolide molecularly imprinted polymer was synthesized by precipitation polymerization using tulathromycin as the template and methacrylic acid as the functional monomer. The polymers revealed different specific adsorption and imprinting factor for macrolides with different spatial arrangement of side chains as well as lactonic ring size. And the molecularly imprinted polymer possessed maximum adsorption capacity (54.1 mg/g) and highest imprinting factor (2.4) toward 15‐membered ring azithromycin. On the basis of molecularly imprinted polymer dispersive solid‐phase extraction, a rapid, selective, and reproducible method for simultaneous determination of seven macrolide antibiotics residues in pork was established by using liquid chromatography with tandem mass spectrometry. At spiking levels of 5, 10, 25, and 100 μg/kg, average recoveries of seven macrolides ranged from 68.6 to 95.5% with intraday and interday relative standard deviations below 8%. The limits of detection and limits of quantification were 0.2–0.5 and 0.5–2.0 μg/kg, respectively.  相似文献   

8.
Reaching trace amounts of mycotoxin contamination requires sensitive and selective analytical tools for their determination. Improving the selectivity of sample pretreatment steps covering new and modern extraction techniques is one way to achieve it. Molecularly imprinted polymers as selective sorbent for extraction undoubtedly meet these criteria. The presented work is focused on the hyphenation of on‐line molecularly imprinted solid‐phase extraction with a chromatography system using a column‐switching approach. Making a critical comparison with a simultaneously developed off‐line extraction procedure, evaluation of pros and cons of each method, and determining the reliability of both methods on a real sample analysis were carried out. Both high‐performance liquid chromatography methods, using off‐line extraction on molecularly imprinted polymer and an on‐line column‐switching approach, were validated, and the validation results were compared against each other. Although automation leads to significant time savings, fewer human errors, and required no handling of toxic solvents, it reached worse detection limits (15 versus 6 μg/L), worse recovery values (68.3–123.5 versus 81.2–109.9%), and worse efficiency throughout the entire clean‐up process in comparison with the off‐line extraction method. The difficulties encountered, the compromises made during the optimization of on‐line coupling and their critical evaluation are presented in detail.  相似文献   

9.
l ‐Kynurenine is an endogenous metabolite generated by the catabolic pathway of l ‐tryptophan and it could be a potential biomarker to test the efficacy of several checkpoint inhibitors that have already reached the clinical trials in the antitumor therapy. Thus, a molecularly imprinted polymer specific for the recognition of this metabolite was synthesized and used as innovative system in solid‐phase extraction technique for the specific extraction and quantification of l ‐kynurenine in human urine. The off‐line system was firstly tested on l ‐kynurenine standard solutions, allowing recoveries up to 97.7% (relative standard deviation = 2.2%) and then applied to fortified and deproteinated human urine samples, where a recovery of 84.1% (relative standard deviation = 3.1%) was obtained. The method was validated and it revealed a good linearity in the range of 0.157–20 μg/mL (r= 0.9992). The optimized procedure demonstrated a good feasibility on biological samples, allowing a ready quantification of l ‐kynurenine in the human urine, where the metabolite was found at a very low concentration (0.80 μg/mL). The extraction system developed could attract attention of pharmaceutical industries for l ‐kynurenine production as potential drug in the treatment of autoimmune disorders through its extraction and purification from biological matrixes.  相似文献   

10.
Three types of molecularly imprinted solid‐phase microextraction fibers were fabricated through sol‐gel method using diazinon, parathion‐methyl, and isocarbophos as templates, respectively, and assembled together to construct a multifiber for analysis of organophosphorus pesticides in complex matrices. The multifiber provided large extraction capacity and high imprinting factor up to 3.89. In contrast, the imprinting factor of a single fiber was around 1.6, and the multi‐template imprinted coating showed no selectivity. The multifiber was applied to analyze pesticides in fruits and vegetables. The limits of detection, which ranged from 0.0052 to 0.23 µg/kg, were lower than those obtained by a single molecularly imprinted fiber, and much lower than those reported by other methods. The recoveries of five analytes in spiked apple, cucumber, Chinese cabbage, and cherry tomato samples were 75.1–123.2%. The study shows that the molecularly imprinted multifiber could achieve simultaneous selective extraction and sensitive determination of multiple targets in complex matrices for high‐throughput analysis.  相似文献   

11.
In this study, surface molecularly imprinted polymers were prepared as the selective sorbents for separation of aristolochic acid I in herbal medicine extracts by a facile approach. A less toxic dummy template, ofloxacin, was used to create specific molecule recognition sites for aristolochic acid I in the synthesized polymers. The polymers were characterized by Fourier‐transfer infrared spectroscopy, scanning electron microscopy, thermogravimetric analysis, elemental analysis, and nitrogen adsorption–desorption test. The adsorption capacity was calculated using adsorption kinetics, selectivity, and recycling experiments. The obtained polymers exhibited high thermostability, fast equilibrium time, and excellent binding ability. Subsequently, the polymers applied as the solid‐phase extraction absorbent was proposed and used for the enrichment and analysis of aristolochic acid I in herbal plants. The result showed that the aristolochic acid I was enriched up to 16 times after analysis by using high‐performance liquid chromatography. The good linearity for aristolochic acid I was obtained in the range of 0.1–200 μg/mL (R 2 = 0.9987). The recovery and precision values were obtained (64.94–77.73%, RSDs% ≤ 0.8%, n  = 3) at three spiked concentration levels. This work provided a promising method for selective enrichment, extraction, and purification of aristolochic acid I from complex herbal plants.  相似文献   

12.
This research highlights the application of highly efficient molecularly imprinted solid‐phase extraction for the preconcentration and analysis of melamine in aquaculture feed samples. Melamine‐imprinted polymers were synthesized employing methacrylic acid and ethylene glycol dimethacrylate as functional monomer and cross‐linker, respectively. The characteristics of obtained polymers were evaluated by scanning electron microscopy, Fourier transform infrared spectroscopy and binding experiments. The imprinted polymers showed an excellent adsorption ability for melamine and were applied as special solid‐phase extraction sorbents for the selective cleanup of melamine. An off‐line molecularly imprinted solid‐phase extraction procedure was developed for the separation and enrichment of melamine from aquaculture feed samples prior to high‐performance liquid chromatography analysis. Optimum molecularly imprinted solid‐phase extraction conditions led to recoveries of the target in spiked feed samples in the range 84.6–96.6% and the relative standard deviation less than 3.38% (n = 3). The aquaculture feed sample was determined, and there was no melamine found. The results showed that the molecularly imprinted solid‐phase extraction protocols permitted the sensitive, uncomplicated and inexpensive separation and pre‐treatment of melamine in aquaculture feed samples.  相似文献   

13.
A novel method was developed to simultaneously determine the ciprofloxacin and levofloxacin levels in human urine using an ionic‐liquid‐based, dual‐molecularly imprinted polymer‐coated graphene oxide solid‐phase extraction monolithic column coupled with high‐performance liquid chromatography. The molecularly imprinted monolithic column was prepared using ciprofloxacin and levofloxacin as templates, 1‐vinyl‐3‐ethylimidazolium bromide as the functional monomer, and graphene oxide as the core material. The resulting imprinted monoliths were characterized by scanning electron microscopy and fourier transform‐infrared spectroscopy. The efficiency and capacity of the ionic‐liquid‐based imprinted monolithic column were investigated by varying the synthesis conditions (ciprofloxacin/levofloxacin ratio and template/functional monomer/cross‐linker ratio). The solid‐phase extraction process was optimized by changing the washing and eluting conditions. The results suggested that the proposed ionic‐liquid‐based molecularly imprinted solid‐phase extraction monolithic‐high‐performance liquid chromatography method could separate ciprofloxacin and levofloxacin efficiently and simultaneously from human urine. The mean recoveries of ciprofloxacin and levofloxacin ranged from 89.2 to 93.8 and 86.7 to 94.6%, respectively. The intra‐ and interday relative standard deviation ranged from 0.9 to 3.2 and 0.8 to 2.9%, respectively. Under the optimized conditions, the recoveries of ciprofloxacin and levofloxacin were more than 93.8%.  相似文献   

14.
The aim of this work was to evaluate the use of a molecularly imprinted polymer as a selective solid‐phase extraction sorbent for the clean‐up and pre‐concentration of patulin from apple‐based food products. Ultra high pressure liquid chromatography coupled to ultraviolet absorbance detection was used for the analysis of patulin. The molecularly imprinted polymer was applied, for the first time, to the determination of patulin in apple juice, puree and jam samples spiked within the maximum levels specified by the European Commission No. 1881/2006. High recoveries (>77%) were obtained. The method was validated and found to be linear in the range 2–100 μg/kg with correlation coefficients greater than 0.965 and repeatability relative standard deviation below 11% in all cases. Compared with dispersive solid‐phase extraction (QuEChERS method) and octadecyl sorbent, the molecularly imprinted polymer showed higher recoveries and selectivity for patulin. The application of Affinisep molecularly imprinted polymer as a selective sorbent material for detection of patulin fulfilled the method performance criteria required by the Commission Regulation No. 401/2006, demonstrating the suitability of the technique for the control of patulin at low ppb levels in different apple‐based foods such as juice, puree and jam samples.  相似文献   

15.
The proposed L ‐histidine sensing system composed of a molecularly imprinted solid‐phase microextraction component combined with a molecularly imprinted polymer sensor was used to determine critical levels of test analyte in a complex matrix of highly diluted human blood serum without any non‐specific sorption and false‐positive contributions. The molecularly imprinted polymer was a zwitterionic polymer brush derived from the disodium salt of EDTA and chloranil, grafted to solid‐phase microextraction material. The hyphenated approach was able to detect L ‐histidine quantitatively with a limit of detection as low as 0.0435 ng/mL (RSD = 0.2%, S/N = 3).  相似文献   

16.
Synthesis of 1,3,5,7‐tetranitro‐1,3,5,7‐tetraazacyclooctane and 1,3,5‐trinitro‐1,3,5‐triazacyclohexane by the Bachmann process leads to a mixture of both. The separation of 1,3,5,7‐tetranitro‐1,3,5,7‐tetraazacyclooctane and 1,3,5‐trinitro‐1,3,5‐triazacyclohexane from their mixture is difficult because the sizes and physical properties of these homologous compounds are similar. For this purpose, seven molecularly imprinted polymers have been synthesized for each explosive, and a selective solid‐phase extraction procedure has been developed. A molecularly imprinted polymer, synthesized with 1,3,5,7‐tetranitro‐1,3,5,7‐tetraazacyclooctane as the template, methacrylic acid as the monomer and trimethylolpropane trimethacrylate as the cross‐linking agent in a molar ratio of 1:8:8 showed the best separation capability. A packed cartridge containing this polymer can be reused for 23 solid‐phase extraction cycles without repacking, and the total separation capability toward 1,3,5,7‐tetranitro‐1,3,5,7‐tetraazacyclooctane reached 6.81 mg per gram of polymer. 1,3,5‐Trinitro‐1,3,5‐triazacyclohexane was not detected in the separated 1,3,5,7‐tetranitro‐1,3,5,7‐tetraazacyclooctane by high‐performance liquid chromatography and vice versa. This newly developed method had the advantages of high recovery (100%) and purity, environmental friendliness, and room temperature operability. This study showed that some molecularly imprinted polymers that cannot absorb target analytes well in the solvent in which the polymers were polymerized might have high‐binding capacity for the analytes and show imprinting effects in other solvents.  相似文献   

17.
The development of a simple and effective method for the isolation and purification of sulfadiazine residues in food of animal origin is of great significance since it is a great danger to human health. An off‐line molecularly imprinted solid‐phase extraction with high‐performance liquid chromatography method was proposed for the selective pretreatment and determination of sulfadiazine in eggs, rapidly and effectively. The molecularly imprinted polymer was proved to have a homogeneous spherical structure and porous surface morphology with excellent adsorption capacity of 5258 μg/g for sulfadiazine. The newly established method showed a good linearity in the range of 0–200 μg/L, low limits of detection (0.06 μg/L), acceptable reproducibility (RSD, 2.60–5.03%, n = 3), and satisfactory relative recoveries (78.22–86.10%). It was demonstrated that the proposed molecularly imprinted solid‐phase extraction with high‐performance liquid chromatography method could be applied to determine sulfadiazine in eggs, which simplified the pretreatment procedure and improved the accuracy of the analysis process by reducing the loss of sulfadiazine in the fat‐removing procedure compared with traditional methods. Molecularly imprinted solid‐phase extraction with excellent selectivity and adsorption capacity is a simple, rapid, selective, and effective pretreatment method for the determination of sulfadiazine in egg samples.  相似文献   

18.
In this work, performance of a molecularly imprinted polymer (MIP) as a selective solid‐phase microextraction sorbent for the extraction and enrichment of tramadol in aqueous solution and rabbit brain tissue, is described. Binding properties of MIPs were studied in comparison with their nonimprinted polymer (NIP). Ten milligrams of the optimized MIP was then evaluated as a sorbent, for preconcentration, in molecularly imprinted solid‐phase microextraction (MISPME) of tramadol from aqueous solution and rabbit brain tissue. The analytical method was calibrated in the range of 0.004 ppm (4 ng mL−1) and 10 ppm (10 μg mL−1) in aqueous media and in the ranges of 0.01 and 10 ppm in rabbit brain tissue, respectively. The results indicated significantly higher binding affinity of MIPs to tramadol, in comparison with NIP. The MISPME procedure was developed and optimized with a recovery of 81.12–107.54% in aqueous solution and 76.16–91.20% in rabbit brain tissue. The inter‐ and intra‐day variation values were <8.24 and 5.06%, respectively. Finally the calibrated method was applied for determination of tramadol in real rabbit brain tissue samples after administration of a lethal dose. Our data demonstrated the potential of MISPME for rapid, sensitive and cost‐effective sample analysis.  相似文献   

19.
We describe a stoichiometric approach to the synthesis of molecularly imprinted polymers specific for auramine O. Using the stoichiometric interaction in molecular imprinting, no excess of binding sites is necessary and binding sites are only located inside the imprinted cavities. The free base of the template was obtained to facilitate the interaction with the monomers. Itaconic acid was selected as the functional monomer, and stoichiometric ratio of the interaction with the free base was investigated. The molecularly imprinted polymer preparation conditions such as cross‐linker, molar ratio, porogen were optimized as divinylbenzene, 1:2:20 and chloroform/N,N‐dimethylformamide, respectively. Under the optimum conditions, a good imprinting effect and very high selectivity were achieved. A solid‐phase extraction method was developed using the molecularly imprinted polymers as a sorbent and extraction procedure was optimized. The solid‐phase extraction method showed a high extraction recovery for auramine O in its hydrochloride form and free form compared to its analogues. The results strongly indicated that stoichiometric imprinting is an efficient method for development of high selectivity molecularly imprinted polymers for auramine O.  相似文献   

20.
Molecularly imprinted polymers for strobilurin fungicides were prepared by precipitation polymerization employing azoxystrobin as template molecular together with methacrylic acid monomer and trimethylolpropane triacrylate cross‐linker. Morphological characterization showed molecularly imprinted polymers were uniform spherical particles with about 0.2 μm in diameter, while the morphologies of nonimprinted polymers were irregular bulk. The equilibrium binding and selective experiments proved that molecularly imprinted polymers possessed a higher affinity toward four fungicides compared to nonimprinted polymers and heterogeneous binding sites were found in the molecularly imprinted polymers. Molecularly imprinted solid‐phase extraction conditions, including sample loading solvents, selective washing, and elution solvents, were carefully optimized. The developed method showed good recoveries (70.0–114.0%) with relative standard deviations in range of 1.0–9.8% (n  =  3) for samples (cucumber and peach) spiked at three different levels (10, 50, and 100 μg/ kg). The detection limit (signal/noise = 3) ranged from 0.01 to 0.08 μg/kg. The results demonstrated good potential use of this convenient and highly efficient method for determining trace strobilurin fungicides in agricultural products.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号