首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A simple and sensitive method was developed and validated for the simultaneous determination of 103 pesticide residues in tea by LC‐MS/MS. For the analysis of the pesticide with polarity, thermal lability or low volatility, this LC‐MS/MS method has an advantage over GC. In this work, residual pesticides were extracted from the tea sample with ACN and then purified using Carb‐NH2 SPE cartridges. Using the multiple reaction monitoring mode, the pesticides were quantified and identified by the most abundant and characteristic fragment ions. The recoveries obtained for each pesticide ranged between 65 and 114% at three spiked concentration levels. The intra‐day precisions were lower than 19.6%. Good linear relationships were observed with the correlation coefficients r2 >0.996 for all analytes. The established method was successfully applied to the determination of pesticide residues in real tea samples.  相似文献   

2.
An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the determination of trantinterol enantiomers in rat plasma. Diphenhydramine was employed as the internal standard. The plasma samples were prepared using liquid-liquid extraction with n-hexane-dichloromethane-isopropanol (20:10:1, v/v/v) as the extractant. Trantinterol enantiomers after pre-column derivatization using diacetyl-l-tartaric anhydride (DATAAN) were separated on a C18 column using a gradient solvent programme. The mobile phase was composed of 3 mM ammonium acetate and acetonitrile. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI). Linear calibration curve for each enantiomer was obtained in the concentration range of 1-80 ng/mL, with limit of quantification (LOQ) of 1 ng/mL. The intra- and inter- precision (R.S.D.) values were below 9.6% and accuracy (R.E.) was from −2.4 to 6.2% at all quality control (QC) levels. The developed method was applied to the enantioselective pharmacokinetic study of trantinterol in rats.  相似文献   

3.
-, β- and γ-cyclodextrins (CDs), as well as some of their chemical derivatives, have been tested as chiral resolving agents for the capillary zone electrophoretic resolution of the racemic herbicide dichlorprop, (±)-2-(2,4-dichlorophenoxy)propionic acid, of which only the (+)-isomer is herbicidally active. The complexation constants of the herbicide enantiomers with the cyclodextrin host molecules have been calculated from the electrophoretic migration time data at variable cyclodextrin concentration. The experimental results showed that several of the investigated CDs allowed dichlorprop enantiomer resolution. In particular, a newly synthesised ethylcarbonate derivative of β-CD showed the best enantiomer resolution properties among the tested compounds, while the remaining ones showed inferior or no performances at all. The calculated inclusion constants allowed identification of the best conditions for enantioresolution, and an explanation of the different complexation properties of the investigated compounds has been proposed on the basis of molecular modeling.  相似文献   

4.
荧光衍生化法测定牛奶中氯霉素残留的研究   总被引:4,自引:0,他引:4  
研究氯霉素荧光衍生化反应的实验条件,建立荧光分光光度法测定牛奶中氯霉素残留的新方法。牛奶中的氯霉素,用乙酸乙酯超声提取3次,浓缩,盐水溶解,正己烷脱脂,再经乙酸乙酯反萃取,氮气吹干,经还原,用荧光胺衍生化测定。氯霉素衍生化产物质量浓度在12.5~500ng/mL范围内,相对荧光强度与质量浓度关系为F=1.44 0.1424ρ,r^2=0.9998。加标回收率为81%~87%,相对标准偏差为3.9%~8.4%。本方法牛奶中氯霉素可达2.5ng/mL。  相似文献   

5.
Li HP  Li JH  Li GC  Jen JF 《Talanta》2004,63(3):547-553
A high performance liquid chromatography with fluorescence (HPLC-F) detector was examined to simultaneous determination of airborne carbamates in the workplace of manufactory. The OVS-2 air sampling tube filled with glass fiber filter or quartz fiber and combined filter/XAD-2 were evaluated to collect nine commonly used carbamates (Carbofuran, Isoprocarb, Methomyl, Metolcarb, Thiodicarb, Carbaryl, Oxamyl, Methiocarb, and Prpoxur) from the air of manufactory in high humidity country. After being extracted with acetonitrile from sampling tubes, the carbamates were determined by high performance liquid chromatography with fluorescence detection posterior to on-line derivatization. The collection of carbamates and the recovery of extraction from glass wool fiber in several concentration levels, and from quartz filter were evaluated. The storage stability of carbamates was also tested. Results indicated that the HPLC-fluorescence method offers satisfactory resolution and sensitivity in carbamate analysis. With the glass fiber filter and combined filter/XAD-2, the Carbofuran, Isoprocarb, Methomyl, Metolcarb, and Thiodicarb were stable for a 28-day storage test, Carbaryl and Oxamyl for 14 days, and Methiocarb and Prpoxur for 7 days. All of these pesticides were with detection limit of 3 μg m−3. It is suited for environmental monitoring. The airborne carbamates in different areas of the manufactory were measured.  相似文献   

6.
On the basis of a novel derivatization, a new planar chromatographic method has been developed for the determination of acrylamide (AA) in drinking water at the ultra-trace level. After SPE, the water extracts were oversprayed on a high-performance thin-layer chromatography (HPTLC) silica gel plate with the derivatization agent dansulfinic acid and derivatized in situ. Chromatography was performed with ethyl acetate and the fluorescent product was quantified at 366/>400 nm. Verification was based on HPTLC-ESI/MS, HPTLC-direct analysis in real-time (DART)-TOF/MS and NMR. The routine HPTLC-fluorescence detection (FLD) method was validated for spiked drinking water. The regression analysis was linear (r >0.9918) in the range of 0.1-0.4 microg/L. LOD was calculated to be 0.025 microg/L and experimentally proved for spiked samples at levels down to 0.05 microg/L (S/N = 6) which was suited for monitoring the EU limit value of 0.1 microg/L in drinking water (0.5 microg/L demanded by World Health Organization (WHO)/US Environmental Protection Agency (EPA)). Within-run precision and the mean between-run precision (RSD, n = 3, three concentration levels each) were evaluated to be 4.8 and 11.0%, respectively. The mean recovery (0.1, 0.2, and 0.3 microg/L) was 96% corrected by the internal standard. The method, in comparison with HPLC-MS/MS showed comparable results and demonstrated the accuracy of the method.  相似文献   

7.
The effect of background derivatization on the signal enhancement of pesticide residues extracted from edible oil samples was studied by GC with negative chemical ionization MS. The analytes were extracted by a solvent extraction process, and the extract was subjected to rapid low‐temperature fat precipitation. The residual fatty acids were silylated by derivatization with N,O‐bis(trimethylsilyl)trifluoroacetamide. The chromatograms obtained from the derivatized samples showed higher signal intensity and lower detection levels when compared to the direct analysis without derivatization. The sensitivity levels of the method are either better or comparable to that of previously reported methodologies. The LODs of the analyzed organochlorine, organophosphorus, and synthetic pyrethroid residues in sunflower, rice bran, and ground oil samples were in the range of 0.02–0.5 ng/g, and the LOQs were in the range of 0.1–2 ng/g. The intraday and interday accuracies were in the range of 81–116% with RSDs less than 14%. The recoveries obtained were in the range of 53–89% with the RSD values less than 13% for all the studied pesticide residues.  相似文献   

8.
A sensitive, selective, simple and fast HPLC method based on the formation of derivative with fluorescamine was developed for the determination of memantine (ME) in human plasma. Separation was achieved on a CN column (200 mm×4.6 mm) using acetonitrile-10 mM orthophosphoric acid containing 1 mL/L triethylamine (45:55, v/v) at a flow rate of 1 mL/min. Emission and excitation wavelengths were 480 and 380 nm, respectively. Amantadine was used as an internal standard. Calibration graphs were rectilinear over the range of 1.0-100.0 ng/mL. Limit of detection and limit of quantification were found to be 0.3 and 1.0 ng/mL, respectively. Intra-day and inter-day relative standard deviation values were found to be <2.03%. Average recovery was also found to be around 94%. Proposed method was applied for the pharmacokinetic study in a healthy volunteer after a single oral administration of 20 mg of ME.  相似文献   

9.
吴晓刚  陈孝权  肖海军  刘彬球 《色谱》2015,33(10):1090-1096
采用超高效液相色谱-串联质谱建立了茶叶中草甘膦和草铵膦残留同时快速测定的方法。茶样经超纯水、二氯甲烷提取和C18固相萃取柱净化后,在硼酸盐缓冲液中与9-芴甲氧羰酰氯(FMOC-Cl)进行衍生反应,衍生后产物在C18色谱柱上进行超高效液相色谱分离;质谱检测采用电喷雾正离子化模式和多反应监测模式。结果表明,在0.003125~0.1 mg/L范围内,草甘膦和草铵膦均有良好的线性关系(r> 0.990),检出限(LOD)均为0.03 mg/kg;在添加浓度为0.375、1.5和4.5 mg/kg时,草甘膦的平均回收率为87.37%~99.11%,相对标准偏差(RSD)(n=6)为0.68%~1.35%;草铵膦的平均回收率为81.44%~86.17%,RSD(n=6)为1.01%~2.33%。该方法样品前处理简单,分析时间短,回收率和精密度等均符合农药多残留检测技术的要求,适用于茶叶中草甘膦和草铵膦残留的同时检测。  相似文献   

10.
A methodology for the evaluation of the performance of an analytical method for incurred samples is presented. Since this methodology is based on intra-laboratory information, it is suitable for analytical fields that lack reference materials with incurred analytes and it can be used to evaluate the analytical steps prior to the analytical portion, which are usually excluded in proficiency tests or at the certification of reference materials. This methodology can be based on tests performed on routine samples allowing the collection of information on the more relevant combinations analyte/matrix; therefore, this approach is particularly useful for analytical fields that involve a high number of analyte/matrix combinations, which are difficult to cover even considering the frequent participation in expensive proficiency tests.This approach is based on the development of a model of the performance of the analytical method based on the differential approach for the quantification of measurement uncertainty and on the comparison of recovery associated with each one of the analytical steps whose performance can vary with the analyte origin, for spiked and incurred samples.This approach was applied to the determination of pesticide residues in apples. For the analytes covered, no evidence was found that the studied sample processing and extraction steps performance for this matrix varies with the analyte origins.  相似文献   

11.
茶叶中7种有机磷农药残留量的同时测定   总被引:14,自引:1,他引:13  
采用配有FPD检测器的气相色谱仪测定茶叶中多种有机磷的农药残留量. 对样品的前处理进行了探讨, 结果表明, 样品用乙酸乙酯和少量苯提取, 过硅胶-活性炭柱净化, 同时用乙酸乙酯和少量苯洗脱, 7种有机磷在HP-35柱上得到很好的分离, 且方法准确快速、重现性、回收率好, 符合实际工作需要.  相似文献   

12.
C. Juan  A. Pena  J. Mañes 《Talanta》2007,73(2):246-250
Ochratoxin A (OTA) is a secondary fungal metabolite produced by several moulds, mainly by Aspergillus ochraceus, A. carbonarius, A. niger and by Penicillium verrucosum. The present work shows the results of comparative studies using different procedures for the analysis of OTA in maize bread samples. The studied analytical methods involved extraction with different volumes of PBS/methanol, different extraction apparatus, and clean-up through immunoaffinity columns. The separation and identification were carried out by high-performance liquid chromatography with fluorescence detection. The optimized method for analysis of OTA in maize bread involved extraction with PBS:methanol (50:50), and clean-up with IAC column. The limit of quantification was 0.033 ng g−1. Recoveries ranged from 87% to 102% for fortifications at 2.000 and 0.500 ng g−1, respectively, within-day R.S.D. of 1.4% and 4.7%. The proposed method was applied to 15 samples and the presence of OTA was found in nine samples at concentrations ranging from nd to 2.650 ng g−1.  相似文献   

13.
When it was recognized that chiral drug residues have stereospecific toxicity towards environmental organisms the attention given to enantiomeric fraction determination of chiral drugs in the environment increased. Among various analytical techniques, chiral liquid chromatography (LC) coupled with mass spectrometry (MS) has been widely used due to its simplicity, wide applicability and high sensitivity. In this review, we aim to provide a comprehensive overview and comparison of the types of chiral stationary phases, elution modes and MS detection techniques employed and address the advances and limitations. The impact of the mobile phase composition on enantioseparation and MS detection are discussed based on the different methods developed. In addition, diverse applications for the enantiomeric fraction determination of chiral drugs in environmental matrices using chiral LC and MS are discussed in depth.  相似文献   

14.
Analyte derivatization is advantageous for the analysis of malondialdehyde (MDA) as a biomarker of oxidative stress in biological samples. Conventionally, however, derivatization is time consuming, error-prone and has limited options for automation. We have addressed these challenges for the solid phase analytical derivatization of MDA from small volume tissue homogenate samples. A manual derivatization method was first developed using Amberlite XAD-2 (12 mg) as the solid phase. Subsequently an automated column switching process was developed that provided simultaneous derivatization and extraction of the MDA-DH hydrazone product on a cartridge packed with XAD-2, followed by quantitative elution of the product to an analytical LC column (Waters NovoPak C18, 3.9 x 150 mm). The LOD was 0.02 microg/mL and recovery was quantitative. The method was linear (r(2) >0.999) with precision < 5% from the LOQ (0.06 microg/mL) to at least 35 microg/mL. The method was successfully applied to the analysis of small volume (30 microL) mouse tissue homogenate samples. Endogenous levels of MDA in the tissues ranged from 20 to 40 nmol/g tissue (ca. 0.1-0.2 microg/mL homogenate). Compared to conventional MDA analyses, the current method has advantages in automation, selectivity, precision and sensitivity for analysis from very small sample volumes.  相似文献   

15.
A method to determine the content of free pantothenic acid in various foods by reverse phase liquid chromatography-fluorimetry is reported. It includes a purification of the samples by successive passages through anion and cation exchange cartridges and a post-column derivatization of pantothenic acid as the fluorescent 1-alkylthio-2-alkylisoindole (reaction of beta-alanin, formed by hot alkaline hydrolysis of pantothenic acid, with orthophthaldialdehyde in the presence of 3-mercaptopropionic acid). An enzymatic hydrolysis prior to the purification step (pepsin at 50 degrees C for 3 h, then pantetheinase and alkaline phosphatase at 20 degrees C for 18 h) made it possible to release the bound pantothenic acid and thus to obtain the total Vitamin B5 content of these foodstuffs. The method proposed for the determination of free and bound pantothenic acid gives a good recovery rate (96-101%) and a satisfactory repeatability (R.S.D.r less than 8%). Owing to its low detection limit (0.65 microg g(-1)) and the good resolution of the pantothenic acid peak, it could most probably be applied to the determination of this vitamin in any foodstuff.  相似文献   

16.
In this study, a new capillary electrophoresis (CE) method is described originally for the sensitive and selective determination of short-chain aliphatic amines in biological samples. These amines were converted into their N-hydroxysuccinimidyl fluorescein-O-acetate (SIFA) derivatives and measured by micellar electrokinetic capillary chromatography with laser-induced fluorescence detection. The derivatization conditions and separation parameters for the aliphatic amines were optimized in detail. The SIFA-labeled amines were fully separated within 8.5 min using 25 mM pH 9.6 boric acid electrolyte containing 60 mM sodium dodecyl sulfate (SDS). The parameters of validation such as linearity of response, precision and detection limits were determined. The detection limits were obtained in the range from 0.02 to 0.1 nM, which was the lowest value reported by CE methods. The developed method was successfully employed to monitor aliphatic amines in serum and cells samples. After comparison of other CE methods using different fluorescent probes, the present method represents a powerful tool for the trace determination of aliphatic amines in complex biological samples.  相似文献   

17.
This paper presents the preparation of a candidate certified reference material (CRM) of cypermethrin in green tea, GLHK-11-01a according to the requirements of ISO Guide 34 and 35. Certification of the material was performed using a newly developed isotope dilution mass spectrometry (IDMS) approach, with gas chromatography high resolution mass spectrometry (GC–HRMS) and gas chromatography–tandem mass spectrometry (GC–MS/MS). Statistical analysis (one-way ANOVA) showed excellent agreement of the analytical data sets generated from the two mass spectrometric detections. The characterization methods have also been satisfactorily applied in an Asia-Pacific Metrology Program (APMP) interlaboratory comparison study. Both the GC–HRIDMS and GC–IDMS/MS methods proved to be sufficiently reliable and accurate for certification purpose. The certified value of cypermethrin in dry mass fraction was 148 μg kg−1 and the associated expanded uncertainty was 14 μg kg−1. The uncertainty budget was evaluated from sample in homogeneity, long-term and short-term stability and variability in the characterization procedure. GLHK-11-01a is primarily developed to support the local and wider testing community on need basis in quality assurance work and in seeking accreditation.  相似文献   

18.
A rapid and sensitive method was developed for the simultaneous determination of histamine and histidine by capillary zone electrophoresis with lamp-induced fluorescence detection. A fluoregenic derivatization reagent, naphthalene-2,3-dicarboxaldehyde (NDA) was successfully applied to label the histamine and histidine respectively. The derivatization conditions and separation parameters including pH and concentration of electrolyte and sample injection were optimized in detail. The optimal derivatization reaction was performed with 1.0 mM NDA, 20 mM NaCN, and 20 mM borate buffer, pH 9.1 for 15 min. The separation of NDA-tagged histamine and histidine could be achieved in less than 200 s with 40 mM phosphate buffer (pH 5.8) as the running buffer. The detection limits for histamine and histidine were 5.5 x 10(-9) and 3.8 x 10(-9) M, respectively (S/N = 3). The relative standard derivations for migration time and peak height of derivatives were less than 1.5 and 5.0%, respectively. The method was successfully applied to the analysis of histamine and histidine in the P815 mastocytoma cells and the beer samples.  相似文献   

19.
In situ chiral derivatization was used to obtain diastereomeric amides of ibuprofen for their subsequent extraction with supercritical carbon dioxide. For this purpose, ibuprofen [racemic 2-(4-isobutylphenyl)propionic acids] was previously extracted on a C-18 SPE device and quantitatively transferred into the supercritical fluid extraction (SFE) vessel for derivatization and extraction with (R)-1-(naphthen-1-yl)ethylamine as chiral derivatizing base, and a mixture of 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide and 1-hydroxybenzotriazole as reagents, in order to obtain and extract the corresponding diastereoisomeric amides, which were subsequently determined by liquid chromatography. The influence of different extraction and derivatization variables (pressure, temperature, extraction time in the static and dynamic extraction modes, and amount of chiral base) on the extraction efficiency was studied. Spiked and native urine samples containing ibuprofen were used to demonstrate the application of this method. The absolute recovery, selectivity, precision and accuracy of the combined solid-phase extraction (SPE)/SFE approach were compared to those provided by conventional liquid–liquid extraction. The results indicated that SFE seems to be an effective choice for in situ derivatization since analysis times and solvent consumption were dramatically reduced.  相似文献   

20.
A new high-performance liquid chromatographic method is described for the determination of fatty acids in seed oils. The method was based on precolumn derivatization with 9-fluorenylmethyl chloroformate as a labeling agent and fluorescence detection. Fatty acids were extracted from the samples and subjected to derivatization with the reagent at 60°C for 10?min. The chromatographic separation of 14 fatty acids (C10–C22) was achieved on a combined loading compression octadecyl sulfate (CLC-ODS) column with a run time of 30?min. Three-step gradient elution of a mobile phase consisted of acetonitrile and water was used, and the signal was monitored at excitation and emission wavelengths of 265 and 315?nm, respectively. The method indicated favorable sensitivity and reproducibility for fatty acids’ derivatives. The detection limits, at a signal-to-noise ratio of 3, were 0.01–0.05?µg/ml and relative standard deviations (RSDs) were less than 0.27%. Excellent linear responses were observed with coefficients of 0.9995. This method was applied to quantify fatty acids in white, brown, and black sesame seeds’ oil.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏