首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive, fast and simple method based on magnetic octadecylsilane particles was developed for the extraction of three fat‐soluble vitamins followed by capillary LC (CLC) analysis with UV detection. Magnetic octadecylsilane particles were prepared based on three‐step reactions including co‐precipitation, sol‐gel polymerization and alkylation. The characterization of the prepared product was studied by scanning electron microscope and Fourier‐transform infrared spectrometry. The particles were used as magnetic SPE adsorbent for the extraction of fat‐soluble vitamins in fruit juice‐milk beverage. The extraction condition and efficiency of the particles for fat‐soluble vitamins were investigated. By coupling magnetic SPE with capillary LC with UV detection, low concentrations of fat‐soluble vitamins in fruit juice‐milk beverage can be detected without the interference from other substances in the sample matrix.  相似文献   

2.
A new online concentration method, namely pressure‐assisted field‐enhanced sample injection (PA‐FESI), was developed and compared with FESI for the analysis of water‐soluble vitamins by CZE with UV detection. In PA‐FESI, negative voltage and positive pressure were simultaneously applied to initialize PA‐FESI. PA‐FESI uses the hydrodynamic flow generated by the positive pressure to counterbalance the reverse EOF in the capillary column during electrokinetic sample injection, which allowed a longer injection time than usual FESI mode without compromising the separation efficiency. Using the PA‐FESI method, the LODs of the vitamins were at ng/mL level based on the S/N of 3 and the RSDs of migration time and peak area for each vitamin (1 μg/mL) were less than 5.1%. The developed method was applied to the analysis of water‐soluble vitamins in corns.  相似文献   

3.
Fat‐soluble vitamins play a pivotal role in the progression of atherosclerosis and the development of cardiovascular disease. Therefore, plasma monitoring of their concentrations may be useful in the diagnosis of these disorders as well as in the process of treatment. The study aimed to develop and validate an HPLC–MS/MS method for determination of retinol, α‐tocopherol, 25‐hydroxyvitamin D2 and 25‐hydroxyvitamin D3 in plasma of patients with cardiovascular disease. The analytes were separated on an HPLC Kinetex F5 column via gradient elution with water and methanol, both containing 0.1% (v/v) formic acid. Detection of the analytes was performed on a triple‐quadrupole MS with multiple reaction monitoring via electrospray ionization. The analytes were isolated from plasma samples with liquid–liquid extraction using hexane. Linearity of the analyte calibration curves was confirmed in the ranges 0.02–2 μg/mL for retinol, 0.5–20 μg/mL for α‐tocopherol, 5–100 ng/mL for 25‐hydroxyvitamin D2 and 2–100 ng/mL for 25‐hydroxyvitamin D3. Intra‐ and inter‐assay precision and accuracy of the method were satisfactory. Short‐ and long‐term stabilities of the analytes were determined. The HPLC‐MS/MS method was applied for the determination of the above fat‐soluble vitamin concentrations in patient plasma as potential markers of the cardiovascular disease progression.  相似文献   

4.
Dissolved carbon dioxide flotation–emulsification microextraction technique coupled with high‐performance liquid chromatography was developed for separation and determination of fat‐soluble vitamins (A, D3, E, and K3) in multivitamin pharmaceutical preparations. Dissolved carbon dioxide flotation was used to break up the emulsion of extraction solvent in water and to collect the extraction solvent on the surface of aqueous sample in narrowed capillary part of extraction cell. Carbon dioxide bubbles were generated in situ through the addition of 300 μL of concentrated hydrochloric acid into the alkaline sample solution at pH = 11.5 (1% w/v sodium carbonate), which was sonicated to intensify the carbon dioxide bubble generation. Several factors affecting the extraction process were optimized. Under the optimal conditions, the limits of detection were 0.11, 0.47, 0.20 and 0.35 μg/L for A, E, D3, and K3 vitamins in water samples, respectively. The inter‐day and intra‐day precision of the proposed method were evaluated in terms of the relative standard deviation and were <10.5%.  相似文献   

5.
《Electrophoresis》2017,38(6):886-896
This paper describes an analytical approach, based on LC‐diode array detector‐MS/MS (LC‐DAD‐MS/MS), for characterizing the fat‐soluble micronutrient fraction in rainbow trout (Oncorhynchus mykiss ). Two different procedures were applied to isolate the analytes from liver and muscle tissue: overnight cold saponification to hydrolyze bound forms and to simplify the analysis; matrix solid‐phase dispersion to avoid artifacts and to maintain unaltered the naturally occurring forms. Analytes were separated on a C30 analytical column by using a nonaqueous reversed mobile phase compatible with the atmospheric pressure chemical ionization. Compared to other works, the most relevant advantage of the here illustrated method is the large amount of information obtained with few analytical steps: nine fat‐soluble vitamins (3,4‐dehydroretinol, retinol, cholecalciferol, ergocalciferol, α‐tocopherol, γ‐tocopherol, δ‐tocopherol, phylloquinone, and menaquinone‐4) and eight carotenoids (all‐trans ‐lutein, all‐trans ‐astaxanthin, all‐trans ‐zeaxanthin, all‐trans ‐β‐cryptoxanthin, all‐trans ‐canthaxanthin, all‐trans ‐ζ‐carotene, all‐trans ‐β‐carotene, and all‐trans ‐γ‐carotene) were quantified after the method validation, while other untargeted carotenoids were tentatively identified by exploiting the identification power of the LC‐DAD‐MS/MS hyphenation.  相似文献   

6.
Hydrophilic interaction liquid‐chromatography (HILIC) in conjunction with diode array detection has been applied for the separation of selected‐water‐soluble vitamins using an end‐capped HILIC‐diol column. Vitamins with significant biological importance, such as thiamine (B1), riboflavin (B2), nicotinic acid (B3), nicotinamide (B3), pyridoxine (B6), folic acid (B9), cyanocobalamin (B12) and ascorbic acid (vitamin C) were simultaneously separated. Chromatographic conditions including type and percentage of organic modifier in the mobile phase, pH, type and concentration of buffer salt and flow rate were investigated. ACN was shown to offer superior separation for the compounds tested as compared to methanol, isopropanol and THF. Isocratic separation and analysis were achieved for six vitamins (B1, B2, nicotinic acid/nicotinamide, B6 and C) at ACN–H2O 90:10, containing ammonium acetate 10 mM, triethylamine 20 mM, pH 5.0, using a flow rate of 0.8 mL/min, while a gradient was necessary to resolve a mixture of all eight water‐soluble vitamins. The HILIC method was validated and successfully applied to the analysis of a pharmaceutical formulation and an energy drink negating the need for time consuming clean‐up steps.  相似文献   

7.
A novel, simple, and effective ion‐pair cloud‐point extraction coupled with a gradient high‐performance liquid chromatography method was developed for determination of thiamine (vitamin B1), niacinamide (vitamin B3), pyridoxine (vitamin B6), and riboflavin (vitamin B2) in plasma and urine samples. The extraction and separation of vitamins were achieved based on an ion‐pair formation approach between these ionizable analytes and 1‐heptanesulfonic acid sodium salt as an ion‐pairing agent. Influential variables on the ion‐pair cloud‐point extraction efficiency, such as the ion‐pairing agent concentration, ionic strength, pH, volume of Triton X‐100, extraction temperature, and incubation time have been fully evaluated and optimized. Water‐soluble vitamins were successfully extracted by 1‐heptanesulfonic acid sodium salt (0.2% w/v) as ion‐pairing agent with Triton X‐100 (4% w/v) as surfactant phase at 50°C for 10 min. The calibration curves showed good linearity (r2 > 0.9916) and precision in the concentration ranges of 1‐50 μg/mL for thiamine and niacinamide, 5–100 μg/mL for pyridoxine, and 0.5–20 μg/mL for riboflavin. The recoveries were in the range of 78.0–88.0% with relative standard deviations ranging from 6.2 to 8.2%.  相似文献   

8.
Hydrophobic‐hydrophilic monolithic dual‐phase plates have been prepared by a two‐step polymerization method for two‐dimensional thin‐layer chromatography of low‐molecular‐weight compounds, namely, several dyes. The thin 200 μm poly(glycidyl methacrylate‐co‐ethylene dimethacrylate) layers attached to microscope glass plates were prepared using a UV‐initiated polymerization method within a simple glass mold. After cutting and cleaning the specific area of the layer, the reassembled mold was filled with a polymerization mixture of butyl methacrylate and ethylene dimethacrylate and subsequently irradiated with UV light. During the second polymerization process, the former layer was protected from the UV light with a UV mask. After extracting the porogens and hydrolyzing the poly(glycidyl methacrylate‐co‐ethylene dimethacrylate) area, these two‐dimensional layers were used to separate a mixture of dyes with great difference in their polarity using reversed‐phase chromatography mode within the hydrophobic layer and then hydrophilic interaction chromatography mode along the hydrophilic area. In the latter dimension only the specific spot was developed further. Detection of the separated dyes could be achieved with surface‐enhanced Raman spectroscopy.  相似文献   

9.
A method for the determination of sterols in vegetable oils by CEC with UV–Vis detection, using methacrylate ester‐based monolithic columns, has been developed. To prepare the columns, polymerization mixtures containing monomers of different hydrophobicities were tried. The influence of composition of polymerization mixture was optimized in terms of porogenic solvent, monomers/porogens and monomer/crosslinker ratios. The composition of the mobile phase was also studied. The optimum monolith was obtained with lauryl methacrylate monomer at 60:40% (wt:wt) lauryl methacrylate/ethylene dimethacrylate ratio and 60 wt% porogens with 20 wt% of 1,4‐butanediol (12 wt% 1,4‐butanediol in the polymerization mixture). Excellent resolution between sterols was achieved in less than 7 min with an 85:10:5 v/v/v ACN–2‐propanol–water buffer containing 5 mM Tris at pH 8.0. The limits of detection were lower than 0.04 mM, and inter‐day and column‐to‐column reproducibilities at 0.75 mM were better than 6.2%. The method was applied to the determination of sterols in vegetable oils with different botanical origins and to detect olive oil adulteration with sunflower and soybean oils.  相似文献   

10.
Vitamins A and E are fat‐soluble vitamins that play important roles in several physiological processes. Monitoring their concentrations is needed to detect deficiency and guide therapy. In this study, we developed a high‐performance liquid chromatography method to measure the major forms of vitamin A (retinol) and vitamin E (α‐tocopherol and γ‐tocopherol) in human blood plasma. Vitamins A and E were extracted with hexane and separated on a reversed‐phase column using methanol as the mobile phase. Retinol was detected by ultraviolet absorption, whereas tocopherols were detected by fluorescence emission. The chromatographic cycle time was 4.0 min per sample. The analytical measurement range was 0.03–5.14, 0.32–36.02, and 0.10–9.99 mg/L for retinol, α‐tocopherol, and γ‐tocopherol, respectively. Intr‐aassay and total coefficient of variation were <6.0% for all compounds. This method was traceable to standard reference materials offered by the National Institute of Standards and Technology. Reference intervals were established using plasma samples collected from 51 healthy adult donors and were found to be 0.30–1.20, 6.0–23.0, and 0.3–3.2 mg/L for retinol, α‐tocopherol, and γ‐tocopherol, respectively. In conclusion, we developed and validated a fast, simple, and sensitive high‐performance liquid chromatography method for measuring the major forms of vitamins A and E in human plasma.  相似文献   

11.
Statistical copolymers of 2‐hydroxyethyl methacrylate (HEMA) and 2‐diethylaminoethyl methacrylate (DEA) were synthesized at 50 °C by free‐radical copolymerization in bulk and in a 3 mol L?1 N,N′‐dimethylformamide solution with 2,2′‐azobisisobutyronitrile as an initiator. The solvent effect on the apparent monomer reactivity ratios was attributed to the different aggregation states of HEMA monomer in the different solvents. The copolymers obtained were water‐insoluble at a neutral pH but soluble in an acidic medium when the molar fraction of the DEA content was higher than 0.5. The quaternization of DEA residues increased the hydrophilic character of the copolymers, and they became water‐soluble at a neutral pH when the HEMA content was lower than 0.25. © 2002 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 40: 2427–2434, 2002  相似文献   

12.
Triterpene acids were extracted from the epidermis of Poria cocos (Schw.) Wolf. These acids were found to inhibit the growth of lung cancer cells in vitro and in vivo. An efficient method for the preparative separation of antitumor triterpene acids was established that involves the combination of pH‐zone‐refining counter‐current chromatography and conventional high‐speed counter‐current chromatography. We used pH‐zone‐refining counter‐current chromatography to concentrate the triterpene acids using a two‐phase solvent system composed of petroleum ether/ethyl acetate/methanol/water (3:7:5:5, v/v/v/v), trifluoroacetic acid (10 mM) was added to the upper phase as a retainer, and ammonia (10 mM) was added to the lower phase as an eluter. As a result, 200 mg concentrate of triterpene acids was obtained from 1.0 g of crude extract. The concentrate was further separated by conventional high‐speed counter‐current chromatography using a solvent system composed of petroleum ether/ethyl acetate/methanol/water (0.8:1.2:1.2:0.9, v/v), yielding 50 mg of poricoic acid A and 5 mg of poricoic acid B from 120 mg concentrate, respectively. The inhibitory activity of the major compound on lung A549 cells was examined and poricoic acid A was found to significantly inhibit the growth of A 549 cells.  相似文献   

13.
Monolithic columns were synthesized inside 1.02 mm internal diameter fused‐silica lined stainless‐steel tubing. Styrene and butyl, hexyl, lauryl, and glycidyl methacrylates were the functional monomers. Ethylene glycol dimethacrylate and divinylbenzene were the crosslinkers. The glycidyl methacrylate polymer was modified with gold nanoparticles and dodecanethiol (C12). The separation of alkylbenzenes was investigated by isocratic elution in 60:40 v/v acetonitrile/water. The columns based on polystyrene‐co‐divinylbenzene and poly(glycidyl methacrylate)‐co‐ethylene glycol dimethacrylate modified with dodecanethiol did not provide any separation of alkyl benzenes. The poly(hexyl methacrylate)‐co‐ethylene glycol dimethacrylate and poly(lauryl methacrylate)‐co‐ethylene glycol dimethacrylate columns separated the alkyl benzenes with plate heights between 30 and 60 μm (50 μL min?1 and 60°C). Similar efficiency was achieved in the poly(butyl methacrylate)‐co‐ethylene glycol dimethacrylate column, but only at 10 μL min?1 (0.22 mm s?1). Backpressures varied from 0.38 MPa in the hexyl methacrylate to 13.4 MPa in lauryl methacrylate columns (50 μL min?1 and 60°C). Separation of proteins was achieved in all columns with different efficiencies. At 100 μL min?1 and 60°C, the lauryl methacrylate columns provided the best separation, but their low permeability prevented high flow rates. Flow rates up to 500 μL min?1 were possible in the styrene, butyl and hexyl methacrylate columns.  相似文献   

14.
A novel imidazolium‐embedded iodoacetamide‐functionalized silica‐based stationary phase has been prepared by surface radical chain‐transfer polymerization. The stationary phase was characterized by Fourier transform infrared spectrometry, thermogravimetric analysis, and element analysis. Fast and efficient separations of polar analytes, such as nucleosides and nucleic acid bases, water‐soluble vitamins and saponins, were well achieved in hydrophilic interaction chromatography mode. Additionally, a mixed mode of hydrophilic interaction and reversed‐phase could be also obtained in the analysis of polar and nonpolar compounds, including weak acidic phenols, basic anilines and positional isomers, with high resolution and molecular‐planarity selectivity, outperforming the commercially available amino column. Moreover, simultaneous separation of polar and nonpolar compounds was also achieved. In conclusion, the multimodal retention capabilities of the imidazolium‐embedded iodoacetamide‐functionalized silica‐based column could offer a wide range of retention behavior and flexible selectivity toward hydrophilic and hydrophobic compounds.  相似文献   

15.
Analysis of water‐soluble vitamins has been tremendously approached through the last decades. A multitude of HPLC methods have been reported with a variety of advantages/shortcomings, yet, the design space of HPLC analysis of these vitamins was not defined in any of these reports. As per the food and drug administration (FDA), implementing the quality by design approach for the analysis of commercially available mixtures is hypothesized to enhance the pharmaceutical industry via facilitating the process of analytical method development and approval. This work illustrates a multifactorial optimization of three measured plus seven calculated influential HPLC parameters on the analysis of a mixture containing seven common water‐soluble vitamins (B1, B2, B6, B12, C, PABA, and PP). These three measured parameters are gradient time, temperature, and ternary eluent composition (B1/B2) and the seven calculated parameters are flow rate, column length, column internal diameter, dwell volume, extracolumn volume, %B (start), and %B (end). The design is based on 12 experiments in which, examining of the multifactorial effects of these 3 + 7 parameters on the critical resolution and selectivity, was carried out by systematical variation of all these parameters simultaneously. The 12 basic runs were based on two different gradient time each at two different temperatures, repeated at three different ternary eluent compositions (methanol or acetonitrile or a mixture of both). Multidimensional robust regions of high critical Rs were defined and graphically verified. The optimum method was selected based on the best resolution separation in the shortest run time for a synthetic mixture, followed by application on two pharmaceutical preparations available in the market. The predicted retention times of all peaks were found to be in good match with the virtual ones. In conclusion, the presented report offers an accurate determination of the design space for critical resolution in the analysis of water‐soluble vitamins by HPLC, which would help the regulatory authorities to judge the validity of presented analytical methods for approval.  相似文献   

16.
A simple and specific HPLC method with dual wavelength UV detection for the determination of ergosta‐4,6,8(14),22‐tetraen‐3‐one (ergone) in rat plasma was developed and proved to be efficient. The method used ergosterol as internal standard (IS). Following a single‐step protein precipitation, the analyte and IS were separated on an Inertsil ODS‐3 column with a mobile phase containing methanol–water (99:1, v/v) at a flow rate of 1 mL/min. The analytes were detected by using UV detection at wavelength of 350 (ergone) and 283 (IS) nm, respectively. The calibration curve was linear over the range of 0.1–2.0 µg/mL and the lower limit of quantification was 0.1 µg/mL. The intra‐day and inter‐day precision studies showed good reproducibility with RSD less than 8.5%. The intra‐day and inter‐day accuracy ranged from 95.6 to 104%. Mean extraction recovery was above 95% at the low, medium and high concentrations. The present HPLC‐UV method was simple and reliable. The method described herein had been successfully applied for the pharmacokinetic studies in male SD rats after administration of 20 mg/kg dose of solution of ergone. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
A rapid method combining microwave‐assisted extraction (MAE) and high‐speed counter‐current chromatography (HSCCC) was applied for preparative separation of six bioactive compounds including loganic acid ( I ), isoorientin‐4′‐O‐glucoside ( II ), 6′‐O‐β‐d ‐glucopyranosyl gentiopicroside ( III ), swertiamarin ( IV ), gentiopicroside ( V ), sweroside ( VI ) from traditional Tibetan medicine Gentiana crassicaulis Duthie ex Burk. MAE parameters were predicted by central composite design response surface methodology. That is, 5.0 g dried roots of G. crassicaulis were extracted with 50 mL 57.5% aqueous ethanol under 630 W for 3.39 min. The extract (gentian total glycosides) was separated by HSCCC with n‐butanol/ethyl acetate/methanol/1% acetic acid water (7.5:0.5:0.5:3.5, v/v/v/v) using upper phase mobile in tail‐to‐head elution mode. 16.3, 8.8, 12., 25.1, 40.7, and 21.8 mg of compounds I–VI were obtained with high purities in one run from 500 mg of original sample. The purities and identities of separated components were confirmed using HPLC with photo diode array detection and quadrupole TOF‐MS and NMR spectroscopy. The study reveals that response surface methodology is convenient and highly predictive for optimizing extraction process, MAE coupled with HSCCC could be an expeditious method for extraction and separation of phytochemicals from ethnomedicine.  相似文献   

18.
Biocompatible pH‐sensitive semi‐interpenetration polymeric network hydrogels (semi‐IPN) based on water‐soluble N‐carboxyethyl chitosan (CECS) and 2‐hydroxyethyl methacrylate (HEMA) were synthesized by the photopolymerization technique. pH‐sensitivity, cytotoxicity, morphology, mechanical property, and water state of hydrogel were investigated by a swelling test, methylthiazolydiphenyl‐tetrazolium bromide (MTT) assay, scanning electron microscopy (SEM), universal testing machine, and differential scanning calorimetry (DSC), respectively. The drug release studies were carried out using 5‐Flurouracil as the model drug. The results indicated that the hydrogels were sensitive to pH of the medium and its wet state had good mechanical properties. The results of cytotoxicity and prolonged drug release characteristics revealed the suitability of the hydrogels as drug delivery matrices. The release kinetics was evaluated by fitting the experimental data to standard release equations, and the best fit was obtained with the Higuchi model of the hydrogel. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
A novel (3‐sulfopropyl methacrylate potassium)‐silica hybrid monolithic column for CEC has been prepared by a simple one‐pot approach based on efficient thiol‐ene click chemistry. In this process, the polycondensation of hydrolyzed alkoxysilanes and in situ click reaction of vinyl groups on 3‐sulfopropyl methacrylate potassium and thiol groups on the precondensed siloxanes simultaneously occurred in a pretreated capillary. Homogeneous monolithic matrix with large through‐pores tightly bonded to the inner wall of the capillary was shown by optical microscope and SEM. The minimum plate height of this hybrid monolithic column was determined as 3.9 μm for thiourea. Anilines, alkylbenzenes, and phenols were well separated on this hybrid monolithic column by CEC, which indicated typical reversed‐phase and cation‐exchange chromatographic retention mechanisms of the column.  相似文献   

20.
Superhydrophobic surfaces (SHS) find versatile applications as coatings due to their very high water‐repellency, self‐cleaning, and anti‐icing properties. This investigation describes the preparation of a SHS from surfactant‐free hybrid fluoropolymer latex. In this case, reversible addition‐fragmentation chain transfer (RAFT) polymerization was adopted to prepare a copolymer of 4‐vinyl pyridine (4VP) and vinyl triethoxysilane (VTES), where the pyridine units were quaternized to make the copolymer soluble in water. The copolymer was further used as a macro‐RAFT agent to polymerize 2,2,2‐trifluoroethyl methacrylate (TFEMA) in a surfactant‐free emulsion via polymerization‐induced self‐assembly (PISA). The macro‐RAFT agent contained a small amount of VTES as co‐monomer which was utilized to graft silica nanoparticles (SNPs) onto the P(TFEMA) spheres. The film prepared using the nanocomposite latex exhibited a nano‐structured surface as observed by SEM and AFM analyses. Surface modification of the film with fluorinated trichlorosilane produced an SHS with a water contact angle (WCA) of 151.5°. © 2017 Wiley Periodicals, Inc. J. Polym. Sci., Part A: Polym. Chem. 2018 , 56, 266–275  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号