共查询到20条相似文献,搜索用时 15 毫秒
1.
Rajesh Chitta Tibor Macko Robert Brüll Gerard Van Doremaele Lars‐Christian Heinz 《Journal of polymer science. Part A, Polymer chemistry》2011,49(8):1840-1846
Ethylene‐propylene‐diene terpolymers (EPDM) are generally amorphous and, therefore, do not crystallize from solution. Consequently, fractionation techniques based on crystallization, such as crystallization analysis fractionation or temperature rising elution fractionation, cannot be used to analyze their chemical composition distribution. Moreover, no suitable chromatographic system was known, which would enable to separate them according to their chemical composition. In this study, two different sorbent/solvent systems are tested with regard to the capability to separate EPDM‐terpolymers and ethylene‐propylene (EP)‐copolymers according to chemical composition. While porous graphite/1‐decanol system is selective towards ethylene and ethylidene‐2‐norbornene, carbon coated zirconia/2‐ethyl‐1‐hexanol is preferentially selective towards ethylene. Consequently, the earlier system enables to separate both EP copolymers and EPDM according to the chemical composition and the latter mainly according to the ethylene content. The results prove that the chromatographic separation in both sorbent/solvent systems is not influenced by molar mass of a sample or by its long chain branching. © 2011 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem, 2011 相似文献
2.
The elution behavior of linear polyethylene and isotactic, atactic and syndiotactic polypropylene was tested using three different carbon column packings: porous graphite (Hypercarb), porous zirconium oxide covered with carbon (ZirChrom-CARB), and activated carbon TA 95. Several polar solvents with boiling points above 150°C were selected as mobile phases: 2-ethyl-1-hexanol, n-decanol, cyclohexylacetate, hexylacetate, cyclohexanone, ethylene glycol monobutyl ether and one non-polar solvent, n-decane. Polyethylene standards were completely or partially adsorbed in all tested sorbent/solvent systems. Polypropylene standards were partially adsorbed on Hypercarb and carbon TA95, but did not adsorb on ZirChrom-CARB. ZirChrom-CARB retained polyethylene pronouncedly when 2-ethyl-1-hexanol, cyclohexylacetate or hexylacetate were used as mobile phases at temperature 150 or 160°C, while all three basic stereoisomers of polypropylene eluted in size exclusion mode in these sorbent/solvent pairs. This is very different from the system Hypercarb/1-decanol, which separated polypropylene according to its tacticity. The opposite elution behavior of polyethylene and polypropylene in system ZirChrom-CARB/2-ethyl-1-hexanol (polypropylene eluted, polyethylene fully adsorbed) enabled to realize separation of blends of polyethylene and polypropylene. Ethylene/1-hexene copolymers were separated according to their chemical composition using system Hypercarb/2-ethyl-1-hexanol/1,2,4-trichlorobenzene. 相似文献
3.
4.
K. Manoj Randunu Simone Dimartino R. Kenneth Marcus 《Journal of separation science》2012,35(23):3270-3280
Polypropylene (PP) capillary‐channeled polymer (C‐CP) fiber stationary phases are investigated for applications in HPLC. Specifically, the roles that fiber size and shape, linear velocity, interstitial fraction, and column inner diameter play in separation efficiency were evaluated using a uracil and butylparaben mixture eluted under isocratic conditions. Four fiber types, having nominal diameters ranging from 30 to 65 μm, were used in 250 mm × 2.1 mm columns. Optimum flow characteristics, as judged by plate height and resolution, were observed for 40 μm diameter PP C‐CP fibers packed at an interstitial fraction of ~0.63, over a broad range of linear velocities (~2 to 37 mm/s). The influence of column inner diameter was studied on 1.5, 2.1, and 4.6 mm columns packed at the optimal interstitial fraction. The best performing column in terms of plate height and resolution was the 2.1 mm inner diameter. C‐CP columns were also evaluated for the separation of a protein mixture composed of ribonuclease A, cytochrome c, and transferrin. Results obtained with the biomacromolecules mixture validate the optimal structural and operative conditions determined with the small solutes, laying the groundwork towards biomacromolecule applications, focusing more on the chemical aspects of separations. 相似文献
5.
6.
Piotr Kawczak Yvan Vander Heyden Antoni Nasal Tomasz Bączek Anna Drabczyñska Katarzyna Kieć‐Kononowicz Roman Kaliszan 《Journal of separation science》2010,33(11):1546-1557
A series of newly synthesized 1,3‐purinodiones with potential anticonvulsant activity, exhibiting affinity to adenosine A1 and/or A2A receptors, were subjected to micellar LC (MLC) with SDS as micelle‐forming agent and n‐propanol as organic modifier. Two C18 silica‐based columns were employed in MLC: a particle one and a monolithic. In parallel, those derivatives were also analyzed in RP‐LC on four silica‐based columns and on an immobilized artificial membrane column. The correlations between the relevant logarithms of the retention factors of analytes obtained in MLC, immobilized artificial membrane and RP‐LC systems on the one hand, and the calculated log P (clog P) and log D values (clog D) on the other, were examined. The level of the correlations of retention data from MLC and RP‐LC systems with clog P and clog D obtained is similar but it could be stressed that MLC allows increasing the speed of analysis and using only one mobile phase. Moreover, there is no need of applying an extrapolation procedure in lipophilicity determination. Therefore, the MLC systems, providing chromatographic data in a fast and efficient manner, were demonstrated as promising alternatives to the classical RP‐LC systems to estimate the lipophilicity of drugs and drug candidates. 相似文献
7.
Thomas Dutriez Marion Courtiade Didier Thiébaut Hugues Dulot Fabrice Bertoncini Marie‐Claire Hennion 《Journal of separation science》2010,33(12):1787-1796
In a context of environmental preservation, purification and conversion of heavy petroleum cuts into high‐quality fuel becomes essential. The interest for the characterization of those very complex matrices becomes a trendy analytical challenge, when it comes to get molecular information for the optimization of industrial processes. Among new analytical techniques, high‐temperature 2‐D GC has recently proved its applicability to heavy petroleum matrices, but lacks in selectivity to separate all chemical groups. To gain resolution, heart cutting is demonstrated for LC separation of saturated, aromatic and polar compounds prior to high‐temperature 2‐D GC. Therefore, an extended global resolution was obtained, especially by a better distinction of saturated compounds. This includes iso‐paraffins and biomarker polynaphthenic structures, which are impossible to quantify with MS methods. This new way to analyze heavy petroleum fractions gives innovative opportunities for the construction of global weight distributions by carbon atoms number and by chemical families. This can right now be employed for quantitative analysis of heavy petroleum fractions and for studying conversion processes. 相似文献
8.
Silvia Barbosa Mnica Diaz Guillermo Mabe Esteban A. Brignole Numa Capiati 《Journal of Polymer Science.Polymer Physics》2005,43(17):2361-2369
The analysis of a thermoplastic polymer blend requires a precise separation of the blend components, which is usually performed by selective solvent extraction. However, when the components are high‐molecular‐weight polymers, a complete separation is very difficult. The use of fluids in near critical and supercritical conditions becomes a promising alternative to reach a much more precise separation. In this work, a method to separate reactive and physical blends from high‐molecular‐weight commercial polymers is proposed. Polyethylene (PE)/polystyrene (PS) blends were separated into their components with n‐propane, n‐pentane, and n‐heptane at near critical and supercritical conditions. The selectivity of each solvent was experimentally studied over a wide range of temperatures for assessing the processing windows for the separation of pure components. The entire PE phase was solubilized by n‐pentane and n‐heptane at similar temperatures, whereas propane at supercritical conditions could not dissolve the fraction of high‐molecular‐weight PE. The influence of the blend morphology and composition on the efficiency of the polymer separation was studied. In reactive blends, the in situ copolymer formed was solubilized with the PE phase by chemical affinity. The method proposed for blend separation is easy, rapid, and selective and seems to be a promising tool for blend separation, particularly for reactive blends, for which the isolation of the copolymer is essential for characterization © 2005 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 43: 2361–2369, 2005 相似文献
9.
Determination of nifedipine in dog plasma by high‐performance liquid chromatography with tandem mass spectrometric detection 下载免费PDF全文
Xigui Pan Shunchang Zhou Qinqin Fu Xianming Hu Jianhong Wu 《Biomedical chromatography : BMC》2014,28(7):1036-1040
Nifedipine is a dihydropyridine calcium channel blocker used widely in the management of hypertension and other cardiovascular disorders. In this work, a simple, rapid and sensitive liquid chromatography/tandem mass spectrometry method was developed and validated to determine nifedipine in dog plasma using nimodipine as the internal standard. Chromatographic separation was carried out on a C8 column. The mobile phase consisted of a mixture of acetonitrile, water and formic acid (60:40:0.2, v/v/v) at a flow rate of 0.5 mL/min. Detection was performed on a triple quadrupole tandem mass spectrometer in selected reaction monitoring mode via an atmospheric pressure chemical ionization source. The method has a lower limit of quantification of 0.20 ng/mL with consumption of plasma as low as 0.05 mL. The linear calibration curves were obtained in the concentration range of 0.20–50.0 ng/mL (r = 0.9948). The recoveries of the liquid extraction method were 74.5–84.1%. Intra‐day and inter‐day precisions were 4.1–8.8 and 6.7–7.4%, respectively. The quantification was not interfered with by other plasma components and the method was applied to determine nifedipine in plasma after a single oral administration of two controlled‐release nifedipine tablets to beagle dogs. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
10.
Development of a decaaza‐cyclophane stationary phase for high‐performance liquid chromatography 下载免费PDF全文
Kai Hu Zhifen Deng Bei Wang Yongxia Cui Mingsan Miao Wei Liu Qiong Jiang Wenjie Zhao Yanjie Huang Shusheng Zhang 《Journal of separation science》2015,38(1):60-66
A new stationary phase for high‐performance liquid chromatography was prepared by covalently bonding a heteroatom‐bridged cyclophane onto silica gel using 3‐aminopropyltriethoxysilane as the coupling reagent. The structure of the new material was characterized by infrared spectroscopy, elemental analysis, and thermogravimetric analysis. The linear solvation energy relationship method was successfully employed to evaluate the new phase with a set of 25 solutes, and compared with octadecylsilyl and p‐tert‐butyl‐calix[4]arene bonded stationary phases. The retention characteristics of the new phase are similar to the octadecylsilyl and conventional calixarene phases, and it also has distinctive features. In addition, the chromatographic behavior of the phase was illustrated by eluting alkylbenzenes and inorganic anions in the reversed‐phase mode and anion‐exchange mode, respectively. Thus, multi‐interaction mechanisms and mixed‐mode separation of the new phase can very likely guarantee its promising application in the analysis of complex samples. The column has been successfully employed for the analysis of triazines in milk, and it is demonstrated to be a competitive alternative analytical method for the determination of triazine herbicide residues. 相似文献
11.
A comprehensive library‐based,automated screening procedure for 46 synthetic cannabinoids in serum employing liquid chromatography‐quadrupole ion trap mass spectrometry with high‐temperature electrospray ionization 下载免费PDF全文
Considering the vast variety of synthetic cannabinoids and herbal mixtures – commonly known as ‘Spice’ or ‘K2’ – on the market and the resulting increase of severe intoxications related to their consumption, there is a need in clinical and forensic toxicology for comprehensive up‐to‐date screening methods. The focus of this project aimed at developing and implementing an automated screening procedure for the detection of synthetic cannabinoids in serum using a liquid chromatography‐ion trap‐MS (LC‐MSn) system and a spectra library‐based approach, currently including 46 synthetic cannabinoids and 8 isotope labelled analogues. In the process of method development, a high‐temperature ESI source (IonBoosterTM, Bruker Daltonik) and its effects on the ionization efficiency of the investigated synthetic cannabinoids were evaluated and compared to a conventional ESI source. Despite their structural diversity, all investigated synthetic cannabinoids benefitted from high‐temperature ionization by showing remarkably higher MS intensities compared to conventional ESI. The employed search algorithm matches retention time, MS and MS2/MS3 spectra. With the utilization of the ionBooster source, limits for the automated detection comparable to cut‐off values of routine MRM methods were achieved for the majority of analytes. Even compounds not identified when using a conventional ESI source were detected using the ionBooster‐source. LODs in serum range from 0.1 ng/ml to 0.5 ng/ml. The use of parent compounds as analytical targets offers the possibility of instantly adding new emerging compounds to the library and immediately applying the updated method to serum samples, allowing the rapid adaptation of the screening method to ongoing forensic or clinical requirements. The presented approach can also be applied to other specimens, such as oral fluid or hair, and herbal mixtures and was successfully applied to authentic serum samples. Quantitative MRM results of samples with analyte concentrations above the determined LOD were confirmed as positive findings by the presented method. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献
12.
A novel mechanochemical method of preparation of maleic anhydride grafted polypropylene (MAPP) was developed. The preparation was performed by ball milling of polypropylene (PP) powder, maleic anhydride (MA), and peroxide initiator in balls-containing jars with a planetary ball mill for a certain time. Compared with the conventional melt-mixing method, MAPP obtained through ball-milling technique reveals higher graft degree, particularly alleviated degradation of PP, or even increased molecular mass of the resulting MAPP. Maleic anhydride grafted polyethylene (MAPE) was obtained via this technique, and the optimization of the technique is in progress. The novel technique offers new opportunities in modification of polyolefins, which has also the advantages of solventless, lower process temperature, energy efficient, low cost, and simple running process. Furthermore, it is very easy to obtain purified products. 相似文献
13.
Chromatographic behavior of small organic compounds in low‐temperature high‐performance liquid chromatography using liquid carbon dioxide as the mobile phase 下载免费PDF全文
Tomohiro Motono Takashi Nagai Shinya Kitagawa Hajime Ohtani 《Journal of separation science》2015,38(14):2381-2386
Low‐temperature high‐performance liquid chromatography, in which a loop injector, column, and detection cell were refrigerated at –35ºC, using liquid carbon dioxide as the mobile phase was developed. Small organic compounds (polyaromatic hydrocarbons, alkylbenzenes, and quinones) were separated by low‐temperature high‐performance liquid chromatography at temperatures from –35 to –5ºC. The combination of liquid carbon dioxide mobile phase with an octadecyl‐silica (C18) column provided reversed phase mode separation, and a bare silica‐gel column resulted in normal phase mode separation. In both the cases, nonlinear behavior at approximately –15ºC was found in the relationship between the temperature and the retention factors of the analytes (van't Hoff plots). In contrast to general trends in high‐performance liquid chromatography, the decrease in temperature enhanced the separation efficiency of both the columns. 相似文献
14.
Luigi D'Agnillo J. B. P. Soares A. Penlidis 《Journal of Polymer Science.Polymer Physics》2002,40(10):905-921
The results of an interlaboratory or round‐robin experiment in high‐temperature gel permeation chromatography (HT‐GPC) analysis are presented. The intention was to determine and raise awareness of interlaboratory reproducibility of HT‐GPC techniques. Fifteen laboratories performed analyses of five polyethylene samples and standards SRM 1475 and 1476. Reproducibility, as measured by the interlaboratory standard deviation (sLAB), was greatly influenced by the breadth of the molecular weight distribution (MWD) and branching. The sLAB values for the weight‐average molecular weight (Mw) of linear polyethylenes of narrow and broad MWDs were 4 and 14%, respectively. For branched polymers, GPC viscometry methods are shown to measure significantly higher molecular weights than the noncoupled GPC method, with higher variance. For branched polyethylenes measured with GPC viscometry, the reproducibility of Mw was characterized by sLAB = 18%. Reproducibility of the SRM 1475 standard was better than for unknowns. The results for branched standard SRM 1476 emphasize the important role of the detection method in GPC but call into question the use of this material as a molecular weight standard. For single‐site polyethylene, only a handful of labs measured an MWD that closely matched the Flory distribution. Qualitatively, the responses indicate that many variations in instrument and analytical methods exist among laboratories; this is partly a reflection of the development and refinements that this technique must yet undergo before a truly standard method is widely accepted and practiced. © 2002 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 40: 905–921, 2002 相似文献
15.
Assessing the detectability of antioxidants in two‐dimensional high‐performance liquid chromatography 下载免费PDF全文
Danielle N. Bassanese Xavier A. Conlan Neil W. Barnett Paul G. Stevenson 《Journal of separation science》2015,38(10):1642-1648
This paper explores the analytical figures of merit of two‐dimensional high‐performance liquid chromatography for the separation of antioxidant standards. The cumulative two‐dimensional high‐performance liquid chromatography peak area was calculated for 11 antioxidants by two different methods—the areas reported by the control software and by fitting the data with a Gaussian model; these methods were evaluated for precision and sensitivity. Both methods demonstrated excellent precision in regards to retention time in the second dimension (%RSD below 1.16%) and cumulative second dimension peak area (%RSD below 3.73% from the instrument software and 5.87% for the Gaussian method). Combining areas reported by the high‐performance liquid chromatographic control software displayed superior limits of detection, in the order of 1 × 10?6 M, almost an order of magnitude lower than the Gaussian method for some analytes. The introduction of the countergradient eliminated the strong solvent mismatch between dimensions, leading to a much improved peak shape and better detection limits for quantification. 相似文献
16.
Shiming Li Yu Wang Zhenyu Wang Hang Xiao Chih‐Yu Lo Nancy Rawson Chi‐Tang Ho 《Biomedical chromatography : BMC》2010,24(8):838-845
Since the hydroxylated polymethoxyflavones were isolated from orange and other citrus peels, they have been found to exhibit potent anti‐cancer and anti‐inflammatory activities. Hydroxylated polymethoxyflavones, especially 5‐demethylnobiletin and 5‐hydroxy‐3,6,7,8,3′,4′‐hexamethoxyflavone, exert more potent activities than their counterpart polymethoxyflavones (PMFs). These findings have led to a new era of exploration of hydroxylated polymethoxyflavones and PMFs from the citrus genus for their potential application in nutraceutical, pharmaceuticals and functional foods. A practical and efficient analytical method for quantitatively characterizing the composition of PMFs has only recently been developed, and has applications both in academic research laboratories and quality controls. However, chemical analyses of the hydroxylated polymethoxyflavones have not been previously described. This paper reports the quantitative analysis of six 5‐demethylated PMFs in various commercial orange peel extracts, using high‐performance liquid chromatography with UV detection. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
17.
Method development for separating organic carbonates by ion‐moderated high‐performance liquid chromatography 下载免费PDF全文
Chin Li Cheung 《Journal of separation science》2016,39(23):4484-4491
An ion‐moderated partition high‐performance liquid chromatography method was developed for the separation and identification of common organic carbonates. The separation of organic carbonates was achieved on an ion exclusion column with an exchangeable hydrogen ion. An isocratic, aqueous mobile phase was used for elution and detection was performed with a refractive index detector. The developed method was validated for specificity, linearity, limits of detection and quantification, precision and accuracy. All calibration curves showed excellent linear regression (R2 > 0.9990) within the testing range. The limits of detection were 3.8–30.8 ppm for the analyzed carbonates. Improvements in the peak resolution of the chromatograms were achieved by decreasing the column temperature. Addition of the organic modifier, acetonitrile, to the eluent was found to have insignificant effects on the peak resolution. The developed method was demonstrated for analyzing organic carbonate components in the electrolyte system of a commercial lithium ion battery. 相似文献
18.
《Journal of separation science》2018,41(1):288-302
The application of graphene‐based sorbents in sample preparation techniques has increased significantly since 2011. These materials have good physicochemical properties to be used as sorbent and have shown excellent results in different sample preparation techniques. Graphene and its precursor graphene oxide have been considered to be good candidates to improve the extraction and concentration of different classes of target compounds (e.g., parabens, polycyclic aromatic hydrocarbon, pyrethroids, triazines, and so on) present in complex matrices. Its applications have been employed during the analysis of different matrices (e.g., environmental, biological and food). In this review, we highlight the most important characteristics of graphene‐based material, their properties, synthesis routes, and the most important applications in both off‐line and on‐line sample preparation techniques. The discussion of the off‐line approaches includes methods derived from conventional solid‐phase extraction focusing on the miniaturized magnetic and dispersive modes. The modes of microextraction techniques called stir bar sorptive extraction, solid phase microextraction, and microextraction by packed sorbent are discussed. The on‐line approaches focus on the use of graphene‐based material mainly in on‐line solid phase extraction, its variation called in‐tube solid‐phase microextraction, and on‐line microdialysis systems. 相似文献
19.
Reversed‐phase ion‐pair high‐performance liquid chromatography assay of polyprenyl diphosphate oligomer homologues 下载免费PDF全文
A reversed‐phase ion‐pair high‐performance liquid chromatography procedure was developed for the separation of polyprenyl diphosphate oligomer homologues obtained chemically from plant polyprenols. Tetrabutylammonium phosphate was used as the ion‐pair reagent, and the dependence of the separation quality on pH of ion‐pair reagent was investigated for the first time. The procedure is applicable for the control of commercial available polyprenyl monophosphates (the active components of veterinary drugs Phosprenyl and Gamapren) for the possible presence of polyprenyl diphosphate byproducts. 相似文献
20.
Zhidong Li Qing Fu Shiliang Li Yu Jin Xinmiao Liang 《Journal of separation science》2020,43(15):3006-3016
The chromatographic behavior of a kind of nucleoside peptides, polyoxins, was investigated in this study. Molecular simulation technique was used to elucidate the temperature‐dependent peak sharpening of polyoxins. There was a relatively small energy barrier between the global minimum conformer and the local minimum conformer of polyoxin A and the high temperature helped to quickly cross the energy barrier and accelerate the conformational transformation for getting the global minimum, so that stationary phase could not identify these two conformations and presented a sharp peak. Two kinds of mixed‐mode columns, strong cation exchange or strong anion exchange ligands bonded with C18 (C18SCX and C18SAX) were used to improve separation selectivity of four polyoxins (A, K, F, H). The electrostatic attraction was necessary to increase the retention to ensure that the alkyl chain can give better play to its hydrophobic effect. Therefore, four polyoxins were well separated on C18SCX at pH 2 and they were also well separated on C18SAX at pH 7. In the small‐scale purification of polyoxins, the sample loading of the C18SCX was five times than that of the C18SAX and the purity of the collected four polyoxins was all over 90%. 相似文献