首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A simple, effective, and robust magnetic solid‐phase extraction method was developed using magnetite/reduced graphene oxide nanoparticles as the adsorbent for the simultaneous determination of Sudan dyes (I, II, III, and IV) in foodstuffs. The magnetite/reduced graphene oxide nanoparticles were characterized by X‐ray diffraction, scanning electron microscopy, and vibrating sample magnetometry. The extraction parameters including extraction time, elution solution, and elution time and volume were investigated in detail. Such magnetite/reduced graphene oxide nanoparticles based magnetic solid‐phase extraction in combination with high‐performance liquid chromatography and variable wavelength detection gave the detection limits of 3–6 μg/kg for Sudan I–IV in chili sauce, tomato sauce, chili powder, and chili flake samples. The recoveries were 79.6–108% at three spiked levels with the intra‐ and inter‐day relative standard deviations of 1.2–8.6 and 4.5–9.6%, respectively. The feasibility was further performed by a comparison with commercial alumina‐N. This method is suitable for the routine analysis of Sudan dyes due to its sensitivity, simplicity, and low cost.  相似文献   

2.
A poly(butyl methacrylate‐co‐ethylene dimethacrylate) monolithic column was fabricated and used as a novel sorbent for online solid‐phase extraction coupled to liquid chromatography with tandem mass spectrometry for the simultaneous determination of Sudan I–IV in chili pepper powder. The prepared columns were characterized by scanning electron microscopy, nitrogen adsorption‐desorption, and pressure drop measurements. Online solid‐phase extraction was performed on the synthesized monolithic column using 10 mM ammonium acetate solution as the loading solution with the aid of an online cleanup chromatography system. The desorption of Sudan I–IV was achieved with acetonitrile as the eluting solution at the flow rate of 0.5 mL/min. The extracted analytes were subsequently eluted into a C18 analytical column for chromatographic separation using a mixture of 10% acetonitrile/90% formic acid (0.5%) solution as the mobile phase. Under the optimized conditions, the developed method had linear range of 1.0–50 μg/kg, a detection limit of 0.3 μg/kg, and a quantification limit of 1.0 μg/kg for each analyte. The intraday and interday recoveries of Sudan I–IV in chili pepper powder samples ranged from 94.8 to 100.9% and 94.9 to 99.4%, respectively. The intraday and interday precision were between 3.37–7.01% and 5.01–7.68%, respectively.  相似文献   

3.
An analytical method based on online combination of polymer monolith microextraction (PMME) technique with hydrophilic interaction LC (HILIC)/MS is presented. The extraction was performed with a poly(methacrylic acid‐co‐ethylene glycol dimethacrylate) monolithic column while the subsequent separation was carried out on a Luna silica column by HILIC. After 1:1 v/v dilution with 20 mM phosphate solution at pH 7.0 and centrifugation, urine sample was directly used for extraction. After optimization, 85% ACN (containing 0.3% formic acid v/v) was used for rapid online elution, which was also the mobile phase in HILIC to avoid band broadening during separation or carry‐over that was usually observed in PMME‐RP LC system. Online automation of extraction and separation procedures was realized under the control of a program in this study. The developed method was applied to rapid and sensitive monitoring of three β2‐agonist traces in human urine. The LODs (S/N = 3) of the method were found to be 0.05–0.09 ng/mL of β2‐agonists in urine. The recoveries of three β2‐agonists spiked in five different urine samples ranged from 79.8 to 119.8%, with RSDs less than 18.0%.  相似文献   

4.
In situ ionic‐liquid‐dispersive liquid–liquid microextraction was introduced for extracting Sudan dyes from different liquid samples followed by detection using ultrafast liquid chromatography. The extraction and metathesis reaction can be performed simultaneously, the extraction time was shortened notably and higher enrichment factors can be obtained compared with traditional dispersive liquid–liquid microextraction. When the extraction was coupled with ultrafast liquid chromatography, a green, convenient, cheap, and efficient method for the determination of Sudan dyes was developed. The effects of various experimental factors, including type of extraction solvent, amount of 1‐hexyl‐3‐methylimidazolium chloride, ratio of ammonium hexafluorophosphate to 1‐hexyl‐3‐methylimidazolium chloride, pH value, salt concentration in sample solution, extraction time and centrifugation time were investigated and optimized for the extraction of four kinds of Sudan dyes. The limits of detection for Sudan I, II, III, and IV were 0.324, 0.299, 0.390, and 0.655 ng/mL, respectively. Recoveries obtained by analyzing the seven spiked samples were between 65.95 and 112.82%. The consumption of organic solvent (120 μL acetonitrile per sample) was very low, so it could be considered as a green analytical method.  相似文献   

5.
A nanocomposite of polystyrene‐coated magnetic nanoparticles was successfully synthesized and employed as adsorbent for magnetic solid‐phase extraction of four Sudan dyes (I, II III, and IV) in red wines, juices, and mature vinegars. The prepared magnetic nanoparticles with highly hydrophobic properties have excellent adsorption capacity for these lipophilic Sudan dyes. Extraction conditions were optimized. Experimental results showed that the recoveries of the four Sudan dyes were very satisfactory when 70 mg of polystyrene‐coated magnetic nanoparticles were used and the extraction could be completed within 20 min. It was proved that these magnetic nanoparticles can be reused after an easy washing process. By coupling the magnetic solid‐phase extraction with ultrafast liquid chromatography‐ultraviolet spectrometry, a rapid, green, effective, and sensitive method for the determination of Sudan dyes was developed. The LOD for Sudan I, Sudan II, Sudan III, and Sudan IV were 0.0039, 0.0063, 0.0057, and 0.017 ng/mL, respectively. Recoveries obtained by analyzing spiked water samples at three concentration levels (0.1, 1.0, and 10.0 ng/mL) were between 76.3 and 96.6%. The intra‐ and interday RSDs for the analytes were lower than 9.6%.  相似文献   

6.
In the present study, a novel poly(acrylamide‐coN‐isopropylacrylamide‐co‐ethylene dimethacrylate) monolithic column modified with saline‐modified delaminated layered double hydroxides was developed and exploited as the stationary phase in the polymer monolith microextraction of β‐agonists. Transmission electron microscopy, Fourier transform infrared spectroscopy, scanning electron microscopy, X‐ray photoelectron spectroscopy, and thermal gravimetric analysis with derivative thermogravimetric determination were employed to characterize the monoliths. By coupling with high‐performance liquid chromatography determinations, extraction parameters affecting the extraction efficiency, including sample volume, flow rate, sample pH, eluent volume, and eluent flow rate were investigated with an orthogonal experiment design, L16 (45). Results demonstrated that under the optimal experimental conditions, low limits of detection in the range of 0.025–0.280 ng/mL were obtained with relative standard deviations in the range of 4.3–7.6% (intraday) and 6.7–8.8% (interday). When the developed method was applied to the analysis of β‐agonists in pork samples, recovery values were obtained in the range of 80.5−108.6%.  相似文献   

7.
A restricted‐access material–hybrid monolithic column was prepared based on single‐component organosiloxane and dynamic grafting of δ‐gluconolactone for on‐line solid phase extraction of tetracycline antibiotic residues from milk. The hybrid monolithic column was prepared in a stainless‐steel chromatographic column using methyltrimethoxysilane as the single precursor. δ‐Gluconolactone was covalently coupled to aminopropyl derivatized hybrid monolithic column, which formed hydrophilic structures on the surface of the pore of the restricted‐access material–hybrid monolithic column. The columns were characterized by scanning electron microscopy, thermogravimetric analysis, Fourier transform infrared spectroscopy, nitrogen adsorption, contact angle analysis, dynamic adsorption, and chromatographic performance evaluation. The restricted‐access material–hybrid monolithic column was applied to the on‐line extraction of tetracycline residues from milk. An enrichment factor of 15.8 and a good sample clean‐up effect were obtained under the optimized conditions. The recoveries of the three spiked milk samples were between 81.7 and 102.5% with relative standard deviations (n = 3) in the range of 2–5%. The limits of detection (S/N = 3) for target compounds were in the range of 3.80–9.03 μg/kg. The results show that the on‐line extraction using the restricted‐access material–hybrid monolithic column was powerful for food sample pretreatment with high selectivity and good clean‐up effect.  相似文献   

8.
In this study, an in‐tube solid‐phase microextraction column packed with mesoporous TiO2 nanoparticles, coupled with MALDI–TOF–MS, was applied to the selective enrichment and detection of phosphopeptides in complex biological samples. The mesoporous TiO2 nanoparticles with high specific surface areas, prepared by a sol–gel and solvothermal method, were injected into the capillary using a slurry packing method with in situ polymerized monolithic segments as frits. Compared with the traditional solid‐phase extraction method, the TiO2‐packed column with an effective length of 1 cm exhibited excellent selectivity (α‐casein/β‐casein/BSA molar ratio of 1:1:100) and sensitivity (10 fmol of a β‐casein enzymatic hydrolysis sample) for the enrichment of phosphopeptides. These performance characteristics make this system suitable for the detection of phosphorylated peptides in practical biosamples, such as nonfat milk.  相似文献   

9.
A recently presented new type of “multilayered” organic–inorganic hybrid silica particle packed column YMC‐Triart C18 (50 mm × 4.6 mm, 5 μm) was used for the development of a sequential injection chromatography method for determination of five azo dyes (Sudan I, Sudan II, Sudan III, Sudan orange G, and para red) in selected food seasonings. The use of a novel sorbent brings attractive features, reduced backpressure, and broader chemical stability together with high separation performance, which are discussed and compared with that of three types of columns typically used in medium‐pressure flow chromatography techniques (classic monolithic, narrow monolithic, and core–shell particle columns). The separation was performed in gradient elution mode created by the zone mixing of two mobile phases (acetonitrile/water 90:10, 1.5 mL + acetonitrile/water 100:0, 2.3 mL) at a flow rate of 0.60 mL/min and time of analysis <9.5 min. The spectrophotometric detection wavelengths were set to 400, 480, and 500 nm. The high performance of the developed method with multilayered particle column was well documented and the results indicate a broad capability of sequential injection chromatography.  相似文献   

10.

A new method involving matrix solid-phase dispersion (MSPD) extraction and UPLC in conjunction with photodiode array detection was developed for the rapid and simple determination of Sudan dyes in chili powder. Separation of Sudan I, Sudan II, Sudan III, and Sudan IV was achieved within 2 min on the 1.7 μm Acquity UPLC BEH C18 column by using gradient elution with a mobile phase consisting of acetonitrile–water at a flow rate of 0.5 mL min−1. Optimization of MSPD extraction parameters, such as type of solid sorbent and elution solvent were carried out. Optimal conditions selected for MSPD extraction were 0.25 g of sample, 0.5 g of silica gel as solid sorbent, and 7 mL of acetonitrile–methanol (9:1, v/v) as eluting solvent. Limits of detection ranged between 0.25 and 0.30 mg kg−1 depending on the dye involved. All analytes provided average recoveries from spiked (at 1, 1.5, and 2 mg kg−1) chili powder samples ranging from 81 to 106%. The method was applied to the analysis of chili powder samples obtained from different countries.

  相似文献   

11.
A polar polymethacrylate‐based monolithic column was introduced and evaluated as a hydrophilic interaction CEC stationary phase. The monolithic stationary phase was prepared by in situ copolymerization of a neutral monomer 2‐hydroxyethyl methacrylate and a polar cross‐linker N,N′‐methylene bisacrylamide in a binary porogenic solvent consisting of dodecyl alcohol and toluene. The hydroxyl and amino groups at the surface of the monolithic stationary phase provided polar sites which were responsible for hydrophilic interactions. The composition and proportion of the polymerization mixture was investigated in detail. The mechanical stability and reproducibility of the obtained monolithic column preformed was satisfied. The effects of pH and organic solvent content on the EOF and the separation of amines, nucleosides, and narcotics on the optimized monolithic column were investigated. A typical hydrophilic interaction CEC was observed on the neutral polar stationary phase. The optimized monolithic column can obtain high‐column efficiencies with 62 000–126 000 theoretical plates/m and the RSDs of column‐to‐column (n = 9), run‐to‐run (n = 5), and day‐to‐day (n = 3) reproducibility were less than 6.3%. The calibration curves of these five narcotics exhibited good linearity with R in the range of 0.9959–0.9970 and linear ranges of 1.0–200.0 μg/mL. The detection limits at S/N = 3 were between 0.2 and 1.2 μg/mL. The recoveries of the separation of narcotics on the column were in the range of 84.0–108.6%. The good mechanical stability, reproducibility, and quantitation capacity was suitable for pressure‐assisted CEC applications.  相似文献   

12.
A new series of pyrazolone based azo acid dyes (3a–g) has been synthesized starting from 1‐(p‐sul‐phophenyl)‐3‐methyl‐5‐pyrazolone (1). The synthetic methodology included the nitrosation of p‐sulphophenyl methyl pyrazolone followed by reduction, diazotization and coupling with Naphthol AS derivatives (2a–f), in alkaline medium to yield different acid dyes. Multichromic metal complexes of these dyes (5a–f, 6a–f and 7a–f) with 3d transition metals Chromium, Iron and Copper were also synthesized. The structures of all of newly synthesized compounds were confirmed by analytical data and spectroscopic techniques. The synthesized dyes were applied on leather to assess their light fastness, wash fastness and rubbing fastness and were shown to exhibit high values of 4–5 for majority of dyes.  相似文献   

13.
In this research, a novel strategy was developed to prepare molecularly imprinted polymer (MIP) coated solid-phase microextraction fibers on a large scale with Sudan I as template and stainless steel fibers as substrate. More than 20 fibers could be obtained in one glass tube, and the efficiency and coating repeatability were enhanced remarkably in contrast with the yield of only one fiber in our previous works. The obtained MIP-coated stainless steel fibers were characterized by homogeneous and highly cross-linked coating, good chemical and thermal stabilities, high extraction capacities, and specific selectivities to Sudan I–IV dyes. Based on the systemic optimization of extraction conditions, a simple and cost-effective method based on the coupling of MIP-coated SPME with high-performance liquid chromatography was developed for the fast and selective determination of trace Sudan I–IV dyes in hot chili powder and poultry feed samples. The limits of detection of Sudan I–IV dyes were within 2.5–4.6 ng g?1, and the spiked recoveries were in the range of 86.3–96.3% for hot chili powder sample and 84.6–97.4% for poultry feed sample.  相似文献   

14.
The coadsorption of mixed anionic–nonionic surfactants, sodium dodecylbenzenesulfonate with Triton X‐100, on the surface of eggshell membrane was investigated based on adsorption isotherms to improve the solid‐phase extraction performance of eggshell membrane toward organic contaminants. Results showed that even though excess Triton X‐100 might inhibit the adsorption of sodium dodecylbenzenesulfonate, a low dosage of Triton X‐100 can significantly improve sodium dodecylbenzenesulfonate modification and enhance the extraction efficiency of eggshell membrane from 73.7 to 100.4% because of the formation of mixed hemimicelles. The highest recovery was achieved at 2:8 (Triton X‐100/sodium dodecylbenzenesulfonate mass ratios), and multiple mechanisms involving π–π interactions, hydrophobic effect, and π–π electron donor–acceptor interactions contributed to the strong extraction affinity. When mixed, the Triton X‐100 and sodium dodecylbenzenesulfonate modified eggshell membrane packed cartridge coupled with high‐performance liquid chromatography was applied for the simultaneous determination of trace Sudan I–IV, and low detection limits (0.16–0.26 ng/L) were achieved with satisfactory linearity (R 2 > 0.999) in 10–10 000 μg/L. For real samples, Sudan II and III in one chilli sauce sample were found at 4.3 and 1.7 μg/kg. Sudan I–IV recoveries at three spiked levels were 87.4–102.9% with precisions <6.8%. Comparison with commonly used solid‐phase extraction adsorbents and methods further reflected the superiorities of the proposed adsorbent in sensitivity, retention ability, and applicability.  相似文献   

15.
A preparatively useful one‐step transformation of γ,γ‐disubstituted α‐formyl‐γ‐lactones into trisubstituted γ,δ‐unsaturated aldehydes is described, by means of catalytic amounts of either AcOH or AcOEt in the vapor phase over a glass support. A mechanistic rationale is proposed.  相似文献   

16.
NMR spectra of the synthesized azo dyes, 5‐arylazo‐pyrimidine (1H,3H,5H)‐2,4,6‐triones (5a–g), 1,3‐dimethyl‐5‐arylazo‐pyrimidine (1H,3H,5H)‐2,4,6‐triones (6a–g), and 5‐arylazo‐2‐thioxo‐pyrimidine (1H,3H,5H)‐4,6‐diones (7a–g) were studied in (CD3)2SO (three drops of CD3OD were added into solutions of the dyes in two different concentrations). All dyes showed intramolecular hydrogen bonding. Dyes 5a–7a showed bifurcated intramolecular hydrogen bonds. Tautomeric behaviours of some of N‐methylated azo dyes (6a‐g) were studied in two different concentrations. The solvent–substrate proton exchange of dyes 5a–d, 6a and 7a–e was examined in presence of three drops of CD3OD. The dyes which were soluble in (CD3)2SO containing CD3OD showed isotopic splitting (β‐isotope effect) in the 13C NMR spectra. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
A novel and rapid sample pretreatment technique based on a combination of ultracentrifugation and solid‐phase extraction for the determination of α‐tocopherol in human erythrocyte membranes by high‐performance liquid chromatography with ultraviolet detection is presented in this work. Red blood cell samples were ultracentrifuged (288 000 × g, 3 min, 4°C) in the presence of d ‐mannitol, 4‐(2‐hydroxyethyl)‐1‐piperazineethanesulfonic acid and calcium chloride. The α‐tocopherol was then extracted from the erythrocyte membranes by solid‐phase extraction with n‐hexane in the presence of ascorbic acid. Tocopherol acetate was used as the internal standard. The extract was dissolved in methanol and separated on the monolithic column Chromolith Performance RP‐18e (100 × 4.6 mm) using 100% methanol as the mobile phase. The absorbance of α‐tocopherol was measured at a wavelength of 295 nm. The method was validated and showed sufficient accuracy and precision, ranging from 96.4 to 100.8% and from 4.5 to 6.3%, respectively. Moreover, the developed method was applied to the determination of erythrocyte α‐tocopherol in real samples from patients. The combined ultracentrifugation and solid‐phase extraction technique substantially decreased the time for the sample pretreatment step compared to liquid–liquid extraction and could be applicable for the quantitation of other analytes in erythrocyte membranes.  相似文献   

18.
Polydopamine‐coated Fe3O4 magnetic nanoparticles synthesized through a facile solvothermal reaction and the self‐polymerization of dopamine have been employed as a magnetic solid‐phase extraction sorbent to enrich four phenolic compounds, bisphenol A, tetrabromobisphenol A, (S)‐1,1′‐bi‐2‐naphthol and 2,4,6‐tribromophenol, from environmental waters followed by high‐performance liquid chromatographic detection. Various parameters of the extraction were optimized, including the pH of the sample matrix, the amount of polydopamine‐coated Fe3O4 sorbent, the adsorption time, the enrichment factor of analytes, the elution solvent, and the reusability of the nanoparticles sorbent. The recoveries of these phenols in spiked water samples were 62.0–112.0% with relative standard deviations of 0.8–7.7%, indicating the good reliability of the magnetic solid‐phase extraction with high‐performance liquid chromatography method. In addition, the extraction characteristics of the magnetic polydopamine‐coated Fe3O4 nanoparticles were elucidated comprehensively. It is found that there are hydrophobic, π–π stacking and hydrogen bonding interactions between phenols and more dispersible polydopamine‐coated Fe3O4 in water, among which hydrophobic interaction dominates the magnetic solid‐phase extraction performance.  相似文献   

19.
γ‐Tocotrienol has attracted much attention owing to its multiple health benefits. This study developed and validated a simple, specific, sensitive and reliable LC/MS/MS method to analyze γ‐tocotrienol in rat plasma. Plasma samples (50 μL) were extracted with internal standard solution (25 ng/mL of itraconazole) in acetonitrile (200 μL) with an average recovery of 44.7% and an average matrix effect of ?2.9%. The separation of γ‐tocotrienol and internal standard from the plasma components was achieved with a Waters XTerra® MS C18 column with acetonitrile–water as mobile phase. Analysis was performed under positive ionization electrospray mass spectrometer via the multiple reaction monitoring. The standard curve was linear over a concentration range of 10–1000 ng/mL with correlation coefficient values >0.997. The method was validated with intra‐ and inter‐day accuracy (relative error) ranging from 1.79 to 9.17% and from 2.16 to 9.66%, respectively, and precision (coefficient of variation) ranged from 1.94 to 9.25% and from 2.37 to 10.08%, respectively. Short‐term stability, freeze–thaw stability and the processed sample stability tests were performed. This method was further applied to analyze γ‐tocotrienol plasma concentrations in rats at various time points after administration of a 2 mg/kg single intravenous dose, and a pharmacokinetic profile was successfully obtained. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
An ultra‐high‐performance liquid chromatography–mass spectrometry (UPLC/MS/MS) method was developed and validated for the quantification of trimethylamine‐N‐oxide (TMAO) simultaneously with TMAO‐related molecules l ‐carnitine and γ‐butyrobetaine (GBB) in human blood plasma. The separation of analytes was achieved using a Hydrophilic interaction liquid chromatography (HILIC)‐type column with ammonium acetate–acetonitrile as the mobile phase. TMAO determination was validated according to valid US Food and Drug Administration guidelines. The developed method was successfully applied to plasma samples from healthy volunteers. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号