首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple and sensitive column‐switching HPLC‐UV method was developed for the simultaneous determination of aripiprazole, a novel atypical antipsychotic drug, and its active metabolite, dehydroaripiprazole in human plasma. Aripiprazole, its active metabolite and 7‐[5‐[4‐(3‐chloro‐2‐methylphenyl)‐1‐piperazinyl]pentyloxy]‐3,4‐dihydro‐2(1H)‐quinolinone (OPC‐14558) as an internal standard were extracted from 1 mL of plasma using a mixture of chloroform/n‐heptane (3:7, v/v), and the extract was injected into a column I (TSK BSA‐ODS/S precolumn, 5 μm) for cleanup and column II (C18 STR ODS‐II analytical column, 5 μm) for separation. Peaks were detected with an UV detector set at a wavelength of 254 nm, and the total time for chromatographic separation was ~20 min. Mean absolute recoveries were 74.0 and 74.7% for aripiprazole and dehydroaripiprazole, respectively. Intra‐ and inter‐day CVs were less than 7.5 and 7.1% for aripiprazole concentrations ranging from 2 to 600 ng/mL, and 9.2 and 4.5% for dehydroaripiprazole concentrations ranging from 2 to 160 ng/mL. The validated concentration ranges for this method were 1–500 ng/mL and the limits of detection were 0.5 ng/mL for both aripiprazole and dehydroaripiprazole. This method was applied to pharmacokinetic study in human volunteers and patients taking aripiprazole.  相似文献   

2.
A new fluorinated stationary phase was prepared through thermal immobilization of poly(methyl‐3,3,3‐trifluoropropylsiloxane) onto 5 μm Kromasil silica particles. The best conditions of immobilization time and temperature were determined through a central composite design and response surface methodologies. Physical–chemical characterization using solid‐state 29Si NMR measurements, infrared spectroscopy and elemental analysis showed that the immobilization process was effective to promote a coating of the support that corresponds to a monolayer of polymer. The stationary phase presents selectivity for positional isomers and good peak shape for basic compounds.  相似文献   

3.
A novel generic reverse phase high performance liquid chromatography (RP‐HPLC) method is developed and validated for simultaneous determination of seven pharmaceutically active ingredients, namely, acetaminophen, dextromethorphan, doxylamine, phenylephrine, guaifenesin, caffeine and aspirin. All seven ingredients were quantified in soft gel, syrup and tablet formulations of the over‐the‐counter US‐marketed products, as per the guidelines of the International Conference on Harmonization. The separation was achieved in a 16 min run time on an Agilent Zorbax Phenyl column using a gradient method with two mobile phases. Mobile phase A was 0.15% trifluoro acetic acid in purified water and while mobile phase B was a mixture of acetonitrile and methanol (750:250 v/v) with 0.02% trifluoro acetic acid. The flow rate was 1.0 mL min?1 and injection volume was 10 μL. Detection was performed at 280 nm using a photodiode array detector. As part of the method validation, specificity, linearity, precision and recovery parameters were verified. The concentration and area relationships were linear (R2 > 0.999), over the concentration ranges 20–120 μg mL?1 for acetaminophen, 75–450 μg mL?1 for dextromethorphan, 31.25–187.5 μg mL?1 for doxylamine, 25–150 μg mL?1 for phenylephrine, 25–150 μg mL?1 for aspirin, 6.5–39 μg mL?1 for caffeine and 12–72 μg mL?1 for guaifenesin. The relative standard deviations for precision and intermediate precision were <1.5%. The proposed RP‐HPLC generic method is applicable for routine analysis of cold and cough over‐the‐counter products.  相似文献   

4.
A novel, simple, specific, sensitive and reproducible high‐performance liquid chromatography (HPLC) assay method has been developed and validated for the estimation of tofacitinib in rat plasma. The bioanalytical procedure involves extraction of tofacitinib and itraconazole (internal standard, IS) from rat plasma with a simple liquid–liquid extraction process. The chromatographic analysis was performed on a Waters Alliance system using a gradient mobile phase conditions at a flow rate of 1.0 mL/min and C18 column maintained at 40 ± 1 °C. The eluate was monitored using an UV detector set at 287 nm. Tofacitinib and IS eluted at 6.5 and 8.3 min, respectively and the total run time was 10 min. Method validation was performed as per US Food and Drug Administration guidelines and the results met the acceptance criteria. The calibration curve was linear over a concentration range of 182–5035 ng/mL (r2 = 0.995). The intra‐ and inter‐day precisions were in the range of 1.41–11.2 and 3.66–8.81%, respectively, in rat plasma. The validated HPLC method was successfully applied to a pharmacokinetic study in rats. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
A simple high performance liquid chromatographic method for the determination of process-related impurities in bulk drug of the central anticholinergic compound pridinol mesylate, has been developed and validated. Spectroscopically characterized synthetic impurities were used as standards. The chromatographic separation was optimized employing an experimental design strategy, and was achieved on a C18 column with a mobile phase containing 50 mM potassium phosphate buffer (pH 6.4), MeOH and 2-propanol (20:69:11, v/v/v), delivered at a flow rate of 1.0 mL min−1. UV detection was performed at 245 nm. The optimized method was thoroughly validated, demonstrating to be selective, when the chromatogram was recorded with a diode-array detector and peak purities were evaluated (>0.9995). The method is robust and linear (r2 > 0.99) over the range 0.05-2.5% (5-250% with regards to the 1% specification limit for both process-related impurities); it is also precise, regarding repeatability (RSD ≤ 1.5% for all of the analytes) and intermediate precision aspects and LOQ values for the impurities are below 0.01%. Method accuracy, evidenced by low bias of the results and analyte recoveries in the range of 99.1-102.7%, was assessed at five analyte concentration levels. The usefulness of the determination was also demonstrated through the analysis of different lots of pridinol mesylate bulk substance. The results indicate that the method is suitable for the quality control of the bulk manufacturing of pridinol mesylate drug substance.  相似文献   

6.
A simple, specific, sensitive and reproducible high‐performance liquid chromatography (HPLC) assay method has been developed and validated for the estimation of odanacatib in rat and human plasma. The bioanalytical procedure involves extraction of odanacatib and itraconazole (internal standard, IS) from a 200 μL plasma aliquot with simple liquid–liquid extraction process. Chromatographic separation was achieved on a Symmetry Shield RP18 using an isocratic mobile phase at a flow rate of 0.7 mL/min. The UV detection wave length was 268 nm. Odanacatib and IS eluted at 5.5 and 8.6 min, respectively with a total run time of 10 min. Method validation was performed as per US Food and Drug Administration guidelines and the results met the acceptance criteria. The calibration curve was linear over a concentration range of 50.9–2037 ng/mL (r2 = 0.994). The intra‐ and inter‐day precisions were in the range of 2.06–5.11 and 5.84–13.1%, respectively, in rat plasma and 2.38–7.90 and 6.39–10.2%, respectively, in human plasma. The validated HPLC method was successfully applied to a pharmacokinetic study in rats. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

7.
An anion‐exchange liquid chromatography method for the determination of heparin and its impurities (dermatan sulfate and oversulfated chondroitin sulfate) was developed using chemometric‐assisted optimization, including multivariate experimental design and response surface methodology. The separation of heparin, dermatan sulfate, and oversulfated chondroitin sulfate (Rs above 2.0) was achieved on a Dionex RF IC IonPac AS22 column with a gradient elution of 10–70% of 2.5 M sodium chloride and 20 mM Tris phosphate buffer (pH 2.1) at a flow rate of 0.6 mL/min and UV detection at 215 nm. Method validation shows good linearity (r > 0.99), acceptable precision (%relative standard deviations <11.4%) and trueness (%recovery of 92.3–103.9%) for all analytes. The limits of detection for dermatan sulfate and oversulfated chondroitin sulfate are equivalent to 0.11% w/w (10.5 μg/mL) and 0.07% w/w (7.2 μg/mL), while the limits of quantification are 0.32% w/w (31.5 μg/mL) and 0.22% w/w (22.0 μg/mL) relative to heparin, respectively. The method is specific for heparin, dermatan sulfate, and oversulfated chondroitin sulfate without interference from mobile phase and sample matrices and could be used for accurate quantitation the drug and its impurities in a single run. Applications of the method reveal contents of heparin between 90.3 and 97.8%. Dermatan sulfate and oversulfated chondroitin sulfate were not detected in any of the real‐life samples.  相似文献   

8.
G. Srinubabu  P. Kiran Kumar 《Talanta》2007,71(3):1424-1429
A rapid and sensitive RP-HPLC method with UV detection (260 nm) for routine analysis of voriconazole in a pharmaceutical formulation (Vfend®) was developed. Chromatography was performed with mobile phase containing a mixture of acetonitrile and water (50:50, v/v) with flow rate was of 1.0 ml min−1. Quantitation was accomplished with internal standard method. The procedure was validated for linearity (correlation coefficient = 0.9999), accuracy, robustness and intermediate precision. Experimental design was used for validation of robustness and intermediate precision. To test robustness, three factors were considered. Percentage of acetonitrile in mobile phase, flow rate and pH; an increase in the flow rate results in a decrease of the drug found concentration, while the percentage of organic modifier and pH have no important effect on the response. For intermediate precision measure the variables considered were: analyst, equipment and number of days. The R.S.D. value (0.45%, n = 24) indicated a good precision of the analytical method. The proposed method was simple, highly sensitive, precise and accurate and retention time less than 4 min indicating that the method is useful for routine quality control.  相似文献   

9.
A rapid and sensitive reversed‐phase high‐performance liquid chromatographic (RP‐HPLC) method was developed to investigate pharmacokinetics of columbianadin, one of the main bioactive constituents in the roots of Angelica pubescens f. biserrata, in rat plasma after intravenous administration to rats at two doses of 10 and 20 mg/kg. The method involves a plasma clean‐up step using liquid–liquid extraction by diethyl ether, followed by RP‐HPLC separation and detection. Separation of columbianadin was performed on an analytical Diamonsil? ODS C18 column, with a mobile phase of MeOH–H2O (85 : 15, v/v) at a flow‐rate of 1.0 mL/min, and UV detection was set at 325 nm. The retention time of columbianadin and scoparone (internal standard) was 6.7 and 3.5 min, respectively. The calibration curve was linear over the range of 0.2–20.0 μg/mL (r2 = 0.9986) in rat plasma. The lower limits of detection and quantification were 0.05 and 0.1 μg/mL, respectively. The extraction recovery from plasma was in the range of 81.61–89.93%. The intra‐ and inter‐day precisions (relative standard deviation) were between 1.01 and 9.33%, with accuracies ranging from 89.76 to 109.22%. The results indicated that the method established was suitable for the determination and pharmacokinetic study of columbianadin in rat plasma. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
A simple and specific bioanalytical method based on reversed‐phase high‐performance liquid chromatography (RP‐HPLC) coupled with ultraviolet detection was developed and validated for the determination of a novel valproic acid arylamide, N‐(2‐hydroxyphenyl)‐2‐propylpentanamide (HO‐AAVPA) in rat hepatic microsomes (a subcellular fraction containing phase I enzymes, especially cytochrome P450). The chromatographic separation was achieved using a reversed‐phase Zorbax SB‐C18 column and a mobile phase of acetic acid in water (0.2% v/v) and acetonitrile (40:60 v/v) with a flow rate of 0.5 mL/min. The calibration curve was linear over the range of 882–7060 ng/mL (r2 = 0.9987), and the lower limit of quantification and the lower limit of determination were found to be 882 and 127.99 ng/mL, respectively. The method was validated with excellent sensitivity, and intra‐day accuracy and precision varied from 93.79 to 93.12%, and from 2.12 to 4.36%, respectively. The inter‐day accuracy and precision ranged from 93.29 to 97.30% and from 0.68 to 3.60%, respectively. The recovery of HO‐AAVPA was measured between 91.36 and 97.98%. The assay was successfully applied to the analysis of kinetic metabolism and pharmacokinetic parameters in vitro by a substrate depletion approach. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
A novel, simple, specific, sensitive and reproducible high‐performance liquid chromatography (HPLC) assay method has been developed and validated for the estimation of abiraterone (ART) in rat plasma. The analytical procedure involves extraction of ART and diclofenac (internal standard, IS) from rat plasma with a simple liquid–liquid extraction process. The chromatographic analysis was performed on a Waters Alliance system with a Betasil C18 column maintained at ambient room temperature and an isocratic mobile phase [acetonitrile–water–10 mm potassium dihydrogen phosphate (pH 3.0), 55:5:40, v/v/v] at a flow rate of 1.00 mL/min with a total run time of 10 min. The eluate was monitored using an UV detector set at 255 nm. Method validation was performed as per FDA guidelines and the results met the acceptance criteria. The calibration curve was linear over a concentration range of 93.4–3251 ng/mL (r2 = 0.997). The intra‐ and inter‐day precisions were 0.56–4.98 and 3.03–7.18, respectively, in rat plasma. The validated HPLC method was successfully applied to a pharmacokinetic study of ART in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

12.
The objective of this study was to qualitatively and quantitatively evaluate bovine lactoferrin (bLf) and its stability using a rapid RP‐HPLC method. bLf could be rapidly detected within 20 min and quantitated at levels down to 5 µg/mL, and the equation of linearity was y = 86.10x + 178.31 with the correlation coefficient (r2) 0.9997. Quantitative data obtained in the present study proved the improved RP‐HPLC method to be a sensitive and accurate analytical tool for bLf determination. The proteolytic cleavage of bLf in simulated human gastrointestinal fluids was further analyzed by RP‐HPLC, and found to follow pseudo‐first‐order kinetics. The typical equation obtained by pepsin was log10 [At]/[A0] = ?0.03x (r2 = 0.85), and log10 [At]/[A0] = ?0.01x (r2 = 0.81) for trypsin and chymotrypsin combination. Pepsinolysis of bLf in simulated gastric fluid was relatively fast with the half‐life t1/2 23.1 min. The digestion of bLf in simulated intestinal fluid was slower with about a 3‐fold increase in half‐life (69.3 min). After the complete proteolysis of bLf, small cleaved peptide fragments were fully separated and identified by RP‐HPLC. The proteolytic study indicated that this validated RP‐HPLC was able to evaluate bLf stability though monitoring the derivatization products. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
Hydroxychloroquine (HCQ) is an old antimalarial drug that has proven to be a safe and effective treatment for systemic lupus erythematosus (SLE) and other autoimmune diseases. Since hematic concentration of HCQ is closely related to the therapeutic response, monitoring the levels of the drug and its metabolites in the blood of HCQ‐treated patients helps the clinician in the evaluation of partial or complete unresponsiveness to treatment. We developed and validated a novel ion‐pairing HPLC‐FL method for the simultaneous dosage of HCQ, and its major metabolites desethylhydroxychloroquine, desethylchloroquine and bisdesethylchloroquine, after extraction from whole blood. This methodological approach was used for the analysis of real samples obtained from patients affected by SLE and undergoing HCQ treatment. The same samples were also analyzed using a previously validated LC/MS/MS method and data obtained with the two approaches were in substantial agreement with each other. Results presented in this work indicate that this approach can be successfully used to monitor the level of HCQ and its metabolites in the blood of various categories of patients (i.e. low and high responders, or those not adhering to the therapy). Comparison of HPLC‐FL and LC/MS/MS data confirmed the efficacy of the proposed method for routine clinical analyses.  相似文献   

14.
Using factor analysis and stepwise linear regression methods, two parameters – CMR and ECCR – were selected from eight solute‐related structure parameters as the most retention‐influencing parameters. The relationships between the retention data (k ´) and the two structure parameters were established for 13 O‐aryl,O‐(1‐methylthioethylideneamino)phosphate compounds under a wide range of experimental conditions. The retention data (k ´) of another seven compounds with similar structures were predicted using these QSRR equations. Good agreement was obtained between the experimental k ´ values and predicted ones.  相似文献   

15.
The Copaifera species (Leguminoseae) are popularly known as ‘copaíba’ or ‘copaíva’ and are grown in the states of Amazonas, Pará and Ceará in northern Brazil. The oleoresins obtained from these species have been extensively used owing to their pharmacological potential and their application in cosmetic and pharmaceutical preparations. In the present study, the development and validation of a novel, rapid and efficient RP‐HPLC methodology for the analysis of the diterpene (?)‐copalic acid (CA), pointed out as the only chemical marker of the Copaifera genus, are described. The regression equation (Y = 26,707x ? 29,498) was obtained with good linearity (r2 = 0.9993) and the limits of quantification and detection were 9.182 and 3.032 µg/mL, respectively. The precision and the accuracy of the method were adequate (lower than 4%). Finally, the validation parameters evaluated were satisfactorily met, so the developed method represents a suitable tool for application in the quality control of such natural products. Further studies aiming to develop analytical methodologies for each Copaifera species using a more representative number of chemical markers should be performed. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
A novel, simple, specific, sensitive and reproducible high‐performance liquid chromatography assay method has been developed and validated for the estimation of Orteronel in rat plasma. The bioanalytical procedure involves extraction of Orteronel and phenacetin (internal standard) from rat plasma with a simple liquid–liquid extraction process. The chromatographic analysis was performed on a Waters Alliance system using a gradient mobile phase conditions at a flow rate of 1 mL/min and a C18 column maintained at ambient room temperature. The eluate was monitored using a photodiode array detector set at 242. Orteronel and internal standard eluted at 4.8 and 6.2 min, respectively and the total run time was 9 min. Method validation was performed as per US Food and Drug Administration guidelines and the results met the acceptance criteria. The calibration curve was linear over a concentration range of 100–3149 ng/mL (r2 = 0.995). The intra‐ and inter‐day precisions were in the ranges of 0.31–7.87 and 3.97–6.35, respectively, in rat plasma. The validated HPLC method was successfully applied to a pharmacokinetic study of Orteronel in rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
The development of a rapid and selective capillary electrophoresis method for the quantitation of ramipril and its eight main impurities in pharmaceutical dosage form is described. Ramipril and three of its impurities contain a proline-similar moiety which causes in solution the presence of interconverting cis-trans isomers with respect to the amide bond. The interplay between electrophoretic migration and isomerization may yield the presence of an undesired interconversion zone between the two isomer peaks in the electropherogram, depending on the experimental conditions. Different capillary electrophoresis operative modes and pseudostationary phases were evaluated, both in normal and reverse polarity, in order to find the essential analytical parameters which could make it possible to overcome this issue and thus accurately quantify the analytes. The best results were obtained by using microemulsion electrokinetic chromatography in reverse polarity, where all the compounds which undergo cis-trans interconversion migrate as a single narrow peak. Experimental design led to identification of the following optimised conditions: background electrolyte, microemulsion made by 88.95% of 90 mM phosphate pH 2.5, 1.05% of n-heptane and 10.00% of SDS/n-butanol in 1:2 ratio; voltage, -26 kV; temperature, 17°C. Applying these conditions, the baseline separation of the analytes was obtained in about 10 min. Validation of the method following ICH guidelines was carried out and the procedure was applied to a real sample of ramipril tablets.  相似文献   

18.
A rapid and simple reverse‐phase high‐performance liquid chromatography (RP‐HPLC) was developed and validated for the quantification of kirenol in rat plasma after oral administration. Kirenol and darutoside (internal standard, IS) were extracted from rat plasma using Cleanert™ C18 solid‐phase extraction (SPE) cartridge. Analysis of the extraction was performed on a Thermo ODS‐2 Hypersil C18 reversed‐phase column with a gradient eluent composed of acetonitrile and 0.1% phosphoric acid. The flow rate was 1.0 mL/min and the detection wavelength was set at 215 nm. The calibration curve was linear over the range of 9.756–133.333 µg/mL (r2 = 0.9991) in rat plasma. The lower limits of detection and quantification were 2.857 and 9.756 µg/mL, respectively. The intra‐ and inter‐day precisions (relative standard deviation, RSD) were between 2.24 and 4.46%, with accuracies ranging from 91.80 to 102.74%. The extraction recovery ranged from 98.16 to 107.62% with RSD less than 4.81%. Stability studies showed that kirenol was stable in preparation and analytical process. The present method was successfully applied to the pharmacokinetic study of kirenol in male Sprague–Dawley rats after oral administration at a dose of 50 mg/kg. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
Evidence‐based herbal products with assured quality are assuming importance for complementary and alternative medicine. Traditional medicines by and large are not standardized and validated to meet the new requirements. In the present study, marker (embelin)‐based standardization of a major medicinal plant, Embelia ribes and its polyherbal formulations was attempted. Conditions for the quantitative extraction of the marker compound embelin from E. ribes fruits and herbal formulations were also optimized. Reversed‐phase high‐performance liquid chromatography, coupled with diode array detection (RP‐HPLC–DAD) for the quantification of embelin was developed and validated. Satisfactory results were obtained with respect to linearity (15–250 µg/mL), LOD (3.97 µg/mL), LOQ (13.2 µg/mL), recovery (99.4–103.8%) and precision (1.43–2.87%). The applicability of the method was demonstrated with selected phytopharmaceuticals. The present method was sensitive, accurate, simple and reproducible and therefore can be recommended for marker‐based standardization, and quality assurance of E. ribes herbal formulations. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
The biotransformation of nodakenetin (NANI) by rat liver microsomes in vitro was investigated. Two major polar metabolites were produced by liver microsomes from phenobarbital‐pretreated rats and detected by reversed‐phase high‐performance liquid chromatography (RP‐HPLC) analysis. The chemical structures of two metabolites were firmly identified as 3′(R)‐hydroxy‐nodakenetin‐3′‐ol and 3′(S)‐hydroxy‐nodakenetin‐3′‐ol, respectively, on the basis of their 1H‐NMR, MS and optical rotation analysis. The latter was a new compound. A sensitive, selective and simple RP‐HPLC method has been developed for the simultaneous determination of NANI and its two major metabolites in rat liver microsomes. Chromatographic conditions comprise a C18 column, a mobile phase with MeOH‐H2O (40 : 60, v/v), a total run time of 40 min, and ultraviolet absorbance detection at 330 nm. In the rat heat‐inactivated liver microsomal supernatant, the lower limits of detection and quantification of metabolite I, metabolite II and NANI were 5.0, 2.0, 10.0 ng/mL and 20.0, 5.0, 50.0 ng/mL, respectively, and their calibration curves were linear over the concentration range 50–400, 20–120 and 150–24000 ng/mL, respectively. The results provided a firm basis for further evaluating the pharmacokinetics and clinical efficacy of NANI. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号