The ion mobility behavior of nineteen chemical warfare agents (7 nerve gases, 5 blister agents, 2 lachrymators, 2 blood agents, 3 choking agents) and related compounds including simulants (8 agents) and organic solvents (39) was comparably investigated by the ion mobility spectrometry instrument utilizing weak electric field linear drift tube with corona discharge ionization, ammonia doping, purified inner air drift flow circulation operated at ambient temperature and pressure. Three alkyl methylphosphonofluoridates, tabun, and four organophosphorus simulants gave the intense characteristic positive monomer-derived ion peaks and small dimer-derived ion peaks, and the later ion peaks were increased with the vapor concentrations. VX, RVX and tabun gave both characteristic positive monomer-derived ions and degradation product ions. Nitrogen mustards gave the intense characteristic positive ion peaks, and in addition distinctive negative ion peak appeared from HN3. Mustard gas, lewisite 1, o-chlorobenzylidenemalononitrile and 2-mercaptoethanol gave the characteristic negative ion peaks. Methylphosphonyl difluoride, 2-chloroacetophenone and 1,4-thioxane gave the characteristic ion peaks both in the positive and negative ion mode. 2-Chloroethylethylsulfide and allylisothiocyanate gave weak ion peaks. The marker ion peaks derived from two blood agents and three choking agents were very close to the reactant ion peak in negative ion mode and the respective reduced ion mobility was fluctuated. The reduced ion mobility of the CWA monomer-derived peaks were positively correlated with molecular masses among structurally similar agents such as G-type nerve gases and organophosphorus simulants; V-type nerve gases and nitrogen mustards. The slope values of the calibration plots of the peak heights of the characteristic marker ions versus the vapor concentrations are related to the detection sensitivity, and within chemical warfare agents examined the slope values for sarin, soman, tabun and nitrogen mustards were higher. Some CWA simulants and organic solvents gave the ion peaks eluting at the similar positions of the CWAs, resulting in false positive alarms.  相似文献   

2.
An aspiration type ion mobility spectrometry (IMS) has been used to determine chemical warfare agent (CWA) degradation products from liquid samples. This technique is based on ion mobility which depends on the molecular weight, charge and shape. With this method, it is possible to measure the mobility distribution of positive and negative ion clusters simultaneously in six different electrodes. Each measuring electrode determines a different portion of the ion mobility distribution formed within the cell’s radioactive source. The strongest responses for all CWA degradation products and 2-propanol were seen in the order of sixth, fifth and second channels. On the basis of projection calculation, the fingerprints for 2-propanol and soman (GD; pinacolyl methylphosphonofluoridate) and VX o-ethyl-S-[2(diisopropylamino)ethyl] methylphosphonothioate) degradation products can be separated from each other. The detection levels for ethyl methylphosphonate (EMPA), pinacolyl methylphosphonate (PMPA), and ethylphosphonic acid (EPA) were 37.2 (37.2 μg/ml), 54.1 (54.1 μg/ml) and 55.1 ppm (55.1 μg/ml), respectively. However, the separation efficiency between different CWA degradation products was quite poor. The projections of these compounds were between 0.9976 and 0.9989, and this means that these fingerprints were identical. Thus, it is only possible to get one profile for all these degradation products of soman and VX. The data provided show that IMS is suitable as a simple technique for screening of CWA degradation products.  相似文献   

3.
The chemical warfare agents (CWA) degrade rapidly in aqueous samples and convert to acidic degradation products. Extraction and identification of the degradation products from complex matrices using simple sample preparation and sensitive detection and identification is the most important step in the off-site analysis of samples. In this present study, we report a simple sample preparation step based on ion-pair (IP) solid-phase extraction (SPE) for the extraction of acidic degradation products of CWA namely methyl, ethyl, propyl phosphonic acids, thiodiglycolic acid and benzilic acid. The analysis was performed on GC-MS in electron impact ionization mode. Three IP reagents triethylamine (TEA), tetrabutylammonium bromide (TBAB) and cetyltrimethyl ammonium bromide (CTAB) were used. The recoveries were estimated using the internal and external standard methods. The recovery of the compounds was almost negligible when TEA was used as IP reagent. The recoveries obtained when TBAB and CTAB were used as IP reagents were high and reproducible. The recovery of test chemicals is above 90%, except for methyl phosphonic acid and ethylphosphonic acid (20.6 +/- 3.2% and 35.8 +/- 2.5%, respectively). The minimum detection limits of the method were calculated for all chemicals in both full scan and selected ion monitoring modes. The test chemicals could be detected in microgram per litre quantities by the IP-SPE method.  相似文献   

4.
Identification of dyes in historic textiles was until recently only based on reversed phase liquid chromatography and diode-array detection (RPLC–DAD). Although in the last years mass spectrometry (MS) is increasingly used as a detection system for liquid chromatography, most applications in the field are directed to identification of the molecular ions or in studies dedicated to degradation products which may be used as markers in RPLC–DAD. In the present work, an analytical protocol for the identification of dyes using RPLC/ESI/MS is presented. Atmospheric pressure electrospray ionization (ESI) was applied, in the negative ion monitoring mode. Both single stage and tandem MS (MS/MS) approaches were considered. An ion trap was used as mass analyzer. Experiments are based on the characterization of standards (natural dyes and/or dyed fibers) with the mass spectrometer sequentially working in the following modes: single MS/full scan, followed by plotting chromatograms through ion extraction (IEC) according to mass/charge ratios corresponding to molecular ions; single MS/selected ion monitoring (SIM) mode; tandem MS/single reaction monitoring (SRM) mode; tandem MS/multiple reactions monitoring (MRM) or product ion scanning modes. A faster chromatographic separation could be applied as MS detection readily balanced the selectivity of the analytical process. In a case study, 11 dyes from 3 biological sources were detected in a 0.5 mg historic sample.  相似文献   

5.
Desorption electrospray ionization mass spectrometry (DESI‐MS) has been applied to the direct analysis of sample media for target chemicals, including chemical warfare agents (CWA), without the need for additional sample handling. During the present study, solid‐phase microextraction (SPME) fibers were used to sample the headspace above five organophosphorus CWA, O‐isopropyl methylphosphonofluoridate (sarin, GB), O‐pinacolyl methylphosphonofluoridate (soman, GD), O‐ethyl N,N‐dimethyl phosphoramidocyanidate (tabun, GA), O‐cyclohexyl methylphosphonofluoridate (cyclohexyl sarin, GF) and O‐ethyl S‐2‐diisopropylaminoethyl methyl phosphonothiolate (VX) spiked into glass headspace sampling vials. Following sampling, the SPME fibers were introduced directly into a modified ESI source, enabling rapid and safe DESI of the toxic compounds. A SYNAPT HDMS? instrument was used to acquire time‐aligned parallel (TAP) fragmentation data, which provided both ion mobility and MSn (n = 2 or 3) data useful for the confirmation of CWA. Unique ion mobility profiles were acquired for each compound and characteristic product ions of the ion mobility separated ions were produced in the Triwave? transfer collision region. Up to six full scanning MSn spectra, containing the [M + H]+ ion and up to seven diagnostic product ions, were acquired for each CWA during SPME fiber analysis. A rapid screening approach, based on the developed methodology, was applied to several typical forensic media, including Dacron sampling swabs spiked with 5 µg of CWA. Background interference was minimal and the spiked CWA were readily identified within one minute on the basis of the acquired ion mobility and mass spectrometric data. Copyright © 2010 Crown in the right of Canada. Published by John Wiley & Sons, Ltd.  相似文献   

6.
LC with MS detection was optimized for sensitive and selective analysis of main classes of natural dyes used in ancient times for dyeing textiles -- red anthraquinoids, yellow flavonoids, and known degradation products of flavonols -- hydroxybenzoic acids. Fragmentation patterns of both negative and positive molecular ions for the above mentioned compounds were investigated. Three acquisition modes of MS analysis: scanning, SIM, and multiple reaction monitoring (MRM) in both positive and negative ion modes were optimized and compared with each other and with the UV-Vis diode-array detection. Even though in the applied chromatographic system formic acid was used in the mobile phase, SIM in the negative ion mode was the most selective and sensitive detection for all the investigated compounds when both mixtures of standards and analysis of extracts from archeological samples were concerned, with one exception -- alizarin, for which MS detection in positive ion mode was more sensitive. Detection limits obtained with MS detection for all investigated compounds except quinizarin were lower than the ones obtained with the diode-array UV-Vis detection, making MS detection the most suitable tool for the analysis of natural dyes and their degradation products in extracts from archeological samples.  相似文献   

7.
A sensitive negative chemical ionization (NCI) gas-chromatography/mass spectrometry (GC/MS) method for the detection of estrogens is described. After hydrosis and clean-up by C18 ODS solid phase extraction (SPE) cartridge, the extracts obtained were derivatized with heptafluorobutyric anhydride and analyzed in the negative ion mode by GC/MS. Stability of derivatives was good. Selected ion monitoring (SIM) mode was applied to increase the sensitivity and, when possible, the higher m/z ions were selected to improve identification. The detection limit of the HFB esters in NCI using SIM was below 10 femtograms.  相似文献   

8.
Bis(2-hydroxyethylthio)alkanes and bis(2-hydroxyethylthioalkyl)ethers are important biological and environmental degradation products of sulfur mustard analogs known as sesqui- and oxy-mustards. We used atmospheric pressure chemical ionization mass spectrometry (APCI MS) to acquire characteristic spectra of these compounds in positive and negative ionization modes. Positive APCI mass spectra exhibited [M + H](+); negative APCI MS generated [M + O(2)](-), [M - H](-), and [M - 3H](-); and both positive and negative APCI mass spectra contained fragment ions due to in-source collision-induced dissociation. Product ion scans confirmed the origin of fragment ions observed in single-stage MS. Although the spectra of these compounds were very similar, positive and negative APCI mass spectra of the oxy-mustard hydrolysis product, bis(2-hydroxyethylthiomethyl)ether, differed from the spectra of the other compounds in a manner that suggested a rearrangement to the sesqui-mustard hydrolysis product, bis(2-hydroxyethylthio)methane. We evaluated the [M + O(2)](-) adduct ion for quantification via liquid chromatography-MS/MS in the multiple-reaction monitoring (MRM) mode by constructing calibration curves from three precursor/product ion transitions for all the analytes. Analytical figures of merit generated from the calibration curves indicated the stability and suitability of these transitions for quantification at concentrations in the low ng/mL range. Thus, we are the first to propose a quantitative method predicated on the measurement of product ions generated from the superoxide adduct anion of the sesqui-and oxy-mustard hydrolysis products.  相似文献   

9.
Vapors of four chemical warfare agent (CWA) stimulants, 2-chloroethyl ethyl sulfide (CEES), diethyl malonate (DEM), dimethyl methylphosphonate (DMMP), and methyl salicylate (MeS), were detected, identified, and quantitated using a fully automated, field-deployable, miniature mass spectrometer. Samples were ionized using a glow discharge electron ionization (GDEI) source, and ions were mass analyzed with a cylindrical ion trap (CIT) mass analyzer. A dual-tube thermal desorption system was used to trap compounds on 50:50 Tenax TA/Carboxen 569 sorbent before their thermal release. The sample concentrations ranged from low parts per billion [ppb] to two parts per million [ppm]. Limits of detection (LODs) ranged from 0.26 to 5.0 ppb. Receiver operating characteristic (ROC) curves are presented for each analyte. A sample of CEES at low ppb concentration was combined separately with two interferents, bleach (saturated vapor) and diesel fuel exhaust (1%), as a way to explore the capability of detecting the simulant in an environmental matrix. Also investigated was a mixture of the four CWA simulants (at concentrations in air ranging from 270 to 380 ppb). Tandem mass (MS/MS) spectral data were used to identify and quantify the individual components.  相似文献   

10.
A packed capillary liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the identification of chemical warfare agents, their degradation products and related compounds in synthetic tabun samples and in soil samples collected from a former mustard storage site. A number of organophosphorus and organosulfur compounds that had not been previously characterized were identified, based on acquired high-resolution ESI-MS data. At lower sampling cone voltages, the ESI mass spectra were dominated by protonated, sodiated and protonated acetonitrile adducts and/or their dimers that could be used to confirm the molecular mass of each compound. Structural information was obtained by inducing product ion formation in the ESI interface at higher sampling cone voltages. Representative ESI-MS mass spectra for previously uncharacterized compounds were incorporated into a database as part of an on-going effort in chemical warfare agent detection and identification. The same samples were also analyzed by capillary column gas chromatography (GC)-MS in order to compare an established method with LC-ESI-MS for chemical warfare agent identification. Analysis times and full-scanning sensitivities were similar for both methods, with differences being associated with sample matrix, ease of ionization and compound volatility. GC-MS would be preferred for organic extracts and must be used for the determination of mustard and relatively non-polar organosulfur degradation products, including 1,4- thioxane and 1,4-dithiane, as these compounds do not ionize during ESI-MS. Diols, formed following hydrolysis of mustard and longer-chain sulfur vesicants, may be analyzed using both methods with LC-ESI-MS providing improved chromatographic peak shape. Aqueous samples and extracts would, typically, be analyzed by LC-ESI-MS, since these analyses may be conducted directly without the need for additional sample handling and/or derivatization associated with GC-MS determinations. Organophosphorus compounds, including chemical warfare agents, related compounds and lower volatility hydrolysis products may all be determined during a single LC-ESI- MS analysis. Derivatization of chemical warfare agent hydrolysis products and other compounds with hydroxyl substitution would be required prior to GC-MS analysis, giving LC-ESI-MS a definite advantage over GC-MS for the analysis of samples containing chemical warfare agents and/or their hydrolysis products.  相似文献   

11.
The chemical warfare agent O-ethyl S-(2-diisopropylaminoethyl) methyl phosphonothiolate (VX) and many related degradation products produce poorly diagnostic electron ionization (EI) mass spectra by transmission quadrupole mass spectrometry. Thus, chemical ionization (CI) is often used for these analytes. In this work, pseudomolecular ([M+H]+) ion formation from self-chemical ionization (self-CI) was examined for four VX degradation products containing the diisopropylamine functional group. A person-portable toroidal ion trap mass spectrometer with a gas chromatographic inlet was used with EI, and both fixed-duration and feedback-controlled ionization time. With feedback-controlled ionization, ion cooling (reaction) times and ion formation target values were varied. Evidence for protonation of analytes was observed under all conditions, except for the largest analyte, bis(diisopropylaminoethyl)disulfide which yielded [M+H]+ ions only with increased fixed ionization or ion cooling times. Analysis of triethylamine-d15 provided evidence that [M+H]+ production was likely due to self-CI. Analysis of a degraded VX sample where lengthened ion storage and feedback-controlled ionization time were used resulted in detection of [M+H]+ ions for VX and several relevant degradation products. Dimer ions were also observed for two phosphonate compounds detected in this sample.  相似文献   

12.
Atmospheric pressure photo ionisation has been evaluated for the analysis of brominated flame retardants and their related degradation products by LC-MS. Degradation mixtures obtained from the photochemical degradation of tetrabromobisphenol A and decabromodiphenylether were used as model systems for the assessment of the developed methodology. Negative ion mode gave best results for TBBPA and its degradation compounds. [M - H]- ions were formed without the need of using a doping agent. MS and MS/MS experiments allowed the structural identification of new TBBPA "polymeric" degradation compounds formed by attachment of TBBPA moieties and/or their respective cleavage products. In the case of polybromodiphenylethers, the positive mode provided M*+ ions and gave better results for congeners ranging from mono- to pentabromodiphenylethers whereas for higher bromination degrees, the negative ion mode (providing [M - Br + O]- ions) was best suited. Under both positive and negative ionisation modes, the use of toluene as doping agent gave better results. Liquid chromatography-mass spectrometry by means of atmospheric pressure photo-ionisation was applied to the analysis of aromatic brominated flame retardants and their degradation products. This methodology proved to be particularly useful, for the characterisation and structural identification of some compounds which are not amenable to GC-MS, especially in the case of apolar "polymeric" degradation products of tetrabromobisphenol A investigated in this work.  相似文献   

13.
After World War II approximately 50,000 tons of chemical weapons were dumped in the Baltic Sea by the Soviet Union under the provisions of the Potsdam Conference on Disarmament. These dumped chemical warfare agents still possess a major threat to the marine environment and to human life. Therefore, continue monitoring of these munitions is essential. In this work, we present the application of new solid phase microextraction fibers in analysis of chemical warfare agents and their degradation products. It can be concluded that the best fiber for analysis of sulfur mustard and its degradation products is butyl acrylate (BA), whereas for analysis of organoarsenic compounds and chloroacetophenone, the best fiber is a co-polymer of methyl acrylate and methyl methacrylate (MA/MMA). In order to achieve the lowest LOD and LOQ the samples should be divided into two subsamples. One of them should be analyzed using a BA fiber, and the second one using a MA/MMA fiber. When the fast analysis is required, the microextraction should be performed by use of a butyl acrylate fiber because the extraction efficiency of organoarsenic compounds for this fiber is acceptable. Next, we have elaborated of the HS-SPME-GC-MS/MS method for analysis of CWA degradation products in environmental samples using laboratory obtained fibers The analytical method for analysis of organosulfur and organoarsenic compounds was optimized and validated. The LOD's for all target chemicals were between 0.03 and 0.65 ppb. Then, the analytical method developed by us, was used for the analysis of sediment and pore water samples from the Baltic Sea. During these studies, 80 samples were analyzed. It was found that 25 sediments and 5 pore water samples contained CWA degradation products such as 1,4-dithiane, 1,4-oxathiane or triphenylarsine, the latter being a component of arsine oil. The obtained data is evidence that the CWAs present in the Baltic Sea have leaked into the general marine environment.  相似文献   

14.
Both positive ion and negative ion chemical ionization mass spectra of hydroxycarboxylic acids (hydroxyethanoic acid, 3-hydroxypropanic acid, 2-hydroxypropanoic acid and 1-phenyl-1-hydroxyethanoic acid) show intense oligomeric ions when the samples are evaporated into a chemical ionization source. The observation of oligomeric anionic and cationic species is unusual, and the parallel behavior observed between the positive and negative ion mass spectra is striking. These results are explicable in terms of evaporation of oligomers and their dehydration products from the hot probe, although gas phase clustering reactions of singly charged ions are not excluded. Hydrogen bonding and dehydration provide bonding within each cluster. The structures of the ions have been confirmed by recording the collision induced dissociations of individual cluster ions via their mass analyzed ion kinetic energy spectra. Temperature dependence of the chemical ionization mass spectra provides a method for distinguishing hydrogen bonding from covalent bonding and gives further structural information on the cluster ions.  相似文献   

15.
Capillary electrophoresis (CE) coupled to ion trap mass spectrometry (MS) was evaluated for the separation and identification of chemical warfare agent degradation products (alkylphosphonic acids and alkyl alkylphosphonic acids). Different analytical parameters were optimized in negative ionization mode such as electrolyte composition (15 mM CH(3)COONH(4), pH 8.8), sheath liquid composition (MeOH/H(2)O/NH(3), 75:25:2, v/v/v), nebulization and ion trapping conditions. A standard mixture of five alkylphosphonic (di)acids and five alkyl alkylphosphonic (mono)acids containing isomeric compounds was used in order to evaluate CE selectivity and MS identification capability. The obtained electropherograms revealed that CE selectivity was very limited in the case of alkyl alkylphosphonic acid positional isomers, whereas isomeric isopropylphosphonic and propylphosphonic acids were baseline-separated. CE-MS-MS experiments provided an unambiguous identification of each isomeric co-migrating alkyl alkylphosphonic acids thanks to the presence of specific fragment ions. On the other hand, CE separation was mandatory for the identification of isomeric alkylphosphonic acids, which led to the same fragment ion and could not be differentiated by MS-MS. The developed method was applied to the analysis of soil extracts spiked with the analytes (before or after extraction treatment) and appeared to be very promising since resolution and sensitivity were similar to those observed in deionized water. Especially, analytes were detected and identified in soil extract spiked at 5 microg mL(-1) with each compound before extraction treatment.  相似文献   

16.
The use of chemical warfare agents has become an issue of emerging concern. One of the challenges in analytical monitoring of the extremely toxic ‘V’‐type chemical weapons [O‐alkyl S‐(2‐dialkylamino)ethyl alkylphosphonothiolates] is to distinguish and identify compounds of similar structure. MS analysis of these compounds reveals mostly fragment/product ions representing the amine‐containing residue. Hence, isomers or derivatives with the same amine residue exhibit similar mass spectral patterns in both classical EI/MS and electrospray ionization‐MS, leading to unavoidable ambiguity in the identification of the phosphonate moiety. A set of five ‘V’‐type agents, including O‐ethyl S‐(2‐diisopropylamino)ethyl methylphosphonothiolate (VX), O‐isobutyl S‐(2‐diethylamino)ethyl methylphosphonothiolate (RVX) and O‐ethyl S‐(2‐diethylamino)ethyl methylphosphonothiolate (VM) were studied by liquid chromatography/electrospray ionization/MS, utilizing a QTRAP mass detector. MS/MS enhanced product ion scans and multistage MS3 experiments were carried out. Based on the results, possible fragmentation pathways were proposed, and a method for the differentiation and identification of structural isomers and derivatives of ‘V’‐type chemical warfare agents was obtained. MS/MS enhanced product ion scans at various collision energies provided information‐rich spectra, although many of the product ions obtained were at low abundance. Employing MS3 experiments enhanced the selectivity for those low abundance product ions and provided spectra indicative of the different phosphonate groups. Study of the fragmentation pathways, revealing some less expected structures, was carried out and allowed the formulation of mechanistic rules and the determination of sets of ions typical of specific groups, for example, methylphosphonothiolates versus ethylphosphonothiolates. The new group‐specific ions elucidated in this work are also useful for screening unknown ‘V’‐type agents and related compounds, utilizing precursor ion scan experiments. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
A simultaneous method for the trace determination of acidic, neutral herbicides and their transformation products in estuarine waters has been developed through an on-line solid-phase extraction method followed by liquid chromatography with diode array and mass spectrometric detection. An atmospheric pressure chemical ionization (APCI) interface was used in the negative ionization mode after optimization of the main APCI parameters. Limits of detection ranged from 0.1 to 0.02 ng/ml for 50 ml of acidified estuarine waters preconcentrated into polymeric precolumns and using time-scheduled selected ion monitoring mode. Two degradation products of the acidic herbicides (4-chloro-2-methylphenol and 2,4-dichlorophenol) did not show good signal response using APCI-MS at the concentration studied due to the higher fragmentor voltage needed for their determination. For molinate and the major degradation product of propanil, 3,4-dichloroaniline, positive ion mode was needed for APCI-MS detection. The proposed method was applied to the determination of herbicides in drainage waters from rice fields of the Delta del Ebro (Spain). During the 3-month monitoring of the herbicides, 8-hydroxybentazone and 4-chloro-2-methylphenoxyacetic acid were successively found in those samples.  相似文献   

18.
Sixteen synthetic chemical drugs, often found in adulterated Chinese medicines, were studied by capillary electrophoresis/UV absorbance (CE/UV) and capillary electrophoresis/electrospray ionization mass spectrometry (CE/ESI-MS). Only nine peaks were detected with CZE/UV, but on-line CZE/MS provided clear identification for most compounds. For a real sample of a Chinese medicinal preparation, a few adulterants were identified by their migration times and protonated molecular ions. For coeluting compounds, more reliable identification was achieved by MS/MS in selected reaction monitoring mode. Micellar electrokinetic chromatography (MEKC) using sodium dodecyl sulfate (SDS) provided better separation than capillary zone electrophoresis (CZE), and, under optimal conditions, fourteen peaks were detected using UV detection. In ESI, the interference of SDS was less severe in positive ion mode than in negative ion mode. Up to 20 mM SDS could be used in direct coupling of MEKC with ESI-MS if the mass spectrometer was operated in positive ion mode. Because of better resolution in MEKC, adulterants can be identified without the use of MS/MS.  相似文献   

19.
ESI and APCI ionization techniques in both negative and positive ion modes were evaluated for simultaneous LC-MS analysis of the four tocopherol homologues (alpha, beta, gamma and delta). The ESI and APCI ionization of tocopherols in positive ion mode was not efficient and proceeded via two competitive mechanisms, with the formation of protonated pseudo-molecular ions and molecular ions, which adversely influenced the repeatability of MS signal. Ionization in negative ion mode in both ESI and APCI was more efficient as it only produced target deprotonated pseudo-molecular ions. The APCI in negative ion mode showed larger linearity range, lower detection limits and was less sensitive to the differences in chemical structure of analytes and nature of applied solvents than negative ion ESI. Negative ion APCI was, therefore, chosen for the development of LC-MS method for simultaneous determination of the four tocopherols in foods. A baseline separation of the tocopherols was achieved on novel pentafluorophenyl silica-based column Fluophase PFP. The use of methanol-water (95:5, v/v) as a mobile phase was preferable to the use of acetonitrile-water due to considerable gain in MS signal. The limits of quantifications were 9 ng/mL for alpha-tocopherol, 8 ng/mL for beta- and gamma- and 7.5 ng/mL for delta-tocopherol when 2 microL was injected. This method was successfully applied to determination of tocopherols in sunflower oil and milk.  相似文献   

20.
Steroid sex hormones and related synthetic compounds have been shown to provoke alarming estrogenic effects in aquatic organisms, such as feminization, at very low concentrations (ng/L or pg/L). In this work, different chromatographic techniques, namely, gas chromatography/mass spectrometry (GC/MS), liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS), are discussed for the analysis of estrogens, both free and conjugated, and progestogens, and the sensitivities achieved with the various techniques are inter-compared. GC/MS analyses are usually carried out after derivatization of the analytes with bis(trimethylsilyl)trifluoroacetamide (BSTFA). For LC/MS and LC/MS/MS analyses, different instruments, ionization techniques (electrospray (ESI) and atmospheric pressure chemical ionization (APCI)), ionization modes (negative ion (NI) and positive ion (PI)) and monitoring modes (selected ion monitoring (SIM) and selected reaction monitoring (SRM)) are generally employed. Based on sensitivity and selectivity, LC/ESI-MS/MS is generally the method of choice for determination of estrogens in the NI mode and of progestogens in the PI mode (instrumental detection limits (IDLs) 0.1-10 ng/mL). IDLs achieved by LC/ESI-MS in the SIM mode and by LC/ESI-MS/MS in the SRM mode were, in general, comparable, although the selectivity of the latter is significantly higher and essential to avoid false positive determinations in the analysis of real samples. Conclusions and future perspectives are outlined.  相似文献   