《Electroanalysis》2004,16(21):1785-1790
Binaphthyl‐based crown ethers incorporating anthraquinone, benzoquinone, and 1,4‐dimethoxybezene have been synthesized and tested for Rb+ selective ionophores in the poly(vinyl chloride) (PVC) membrane. The membrane containing NPOE gave a better Rb+ selectivity than those containing either DOA or BPPA as a plasticizer. The response was linear within the concentration range of 1.0×10?5–1.0×10?1 M and the slope was 54.7±0.5 mV/dec. The detection limit was determined to be 9.0×10?6 M and the optimum pH range of the membrane was 6.0–9.0. The ISE membrane exhibits good selectivity for Rb+ over ammonium, alkali metal, and alkaline earth metal ions. Selectivity coefficients for the other metal ions, log KPot were ?2.5 for Li+, ?2.4 for Na+, ?2.0 for H+, ?1.0 for K+, ?1.2 for Cs+, ?1.6 for NH4+, ?4.5 for Mg2+, ?5.0 for Ca2+,?4.9 for Ba2+. The lifetime of the membrane was about one month.  相似文献   

2.
双臂套索冠醚PVC膜碘离子选择电极   总被引:2,自引:2,他引:2  
研究了两种新型双臂套索冠醚1,10-二(5-氯-8-羟基喹啉-7-亚甲基)-1,10-二氮杂-4,7,16-三氧杂-13,19-二硫杂环二十一烷(Ⅰ)和1,13-二(5-甲基-8-羟基喹啉-7-亚甲基)-1,13-二氮杂-4,7,10-三氧杂-16,19-二硫杂环二十一烷(Ⅱ)为载体的PVC膜电极的响应行为;实验结果表明,两电极均显示阴离子响 应,其中对碘离子具有优良的能斯特电位响应性能,线性范围为10^-5-10^-1mol/L,斜率分别为-59.1mV/pcI-和-57.6mV/pcI-;电极具有读数稳定,重复性好,PH值范围宽等优点;将该电极用于药品中碘含量的测定,其结果与药典法一致。  相似文献   

3.
查尔酮冠醚PVC膜钾离子选择性电极的初步研究   总被引:2,自引:0,他引:2  
查尔酮冠醚PVC膜钾离子选择性电极的初步研究李廷盛,蔡汉临,王传林,张建明,魏旭东,胡宏纹(华中师范大学化学系武汉430070))(南京大学化学系南京)关键词查尔酮冠醚PVC膜,钾离子电极,性能钾离子在生物细胞膜内外的浓度梯度对生物膜的能量传输等起着...  相似文献   

4.
《Electroanalysis》2005,17(8):713-718
Five plastic membrane Pb2+‐selective electrodes were prepared based on 1,4‐bis(N‐tosyl‐o‐aminophenoxy)butane I , 1,4‐bis(N‐allyl‐N‐tosyl‐o‐aminophenoxy)butane II , 1,4‐bis(N‐benzyl‐N‐tosyl‐o‐aminophenoxy)butane III , 1,4‐bis[N‐(o‐allyloxybenzyl)‐N‐tosyl‐o‐aminophenoxy]butane IV , and 1,4‐bis(N‐octyl‐N‐tosyl‐o‐aminophenoxy)butane V as neutral carriers. The electrodes exhibited nearly Nernstian responses over the concentration ranges, 2.5×10?4–4.0×10?2, 2.5×10?5–4.0×10?2, 7.9×10?5–4.0×10?2, 2.2×10?5–4.0×10?2, and 1.9×10?4–4.0×10?2 M for electrodes composed with the ionophores I–V , respectively. All electrodes showed pH range of about 4.0 to 11.5 and working temperature range of 22 to 70 °C with isothermal temperature coefficients of 1.19×10?3, 1.16×10?3, 1.16×10?3, 1.00×10?3 , and 1.32×10?3 V/°C for electrodes I–V respectively.  相似文献   

5.
The effect of component contents and membrane thickness on the detection limit (DL), slope (m), linear range (LR) and response time (RT) of Pb2+ solid contact potentiometric ion selective electrodes (SCISE) based on 4,10‐diaza‐2,3,11,12‐dibenzo‐18‐crown‐6 (1), 4,10‐diaza‐2,3,11,12‐di(4‐tert‐butylbenzo)‐18‐crown‐6 (2) and 4,10‐diaza‐2,3,11,12‐dibenzo‐18‐crown‐6‐N,N′‐di(carboxymethyl) (3) as ionophores was studied by open circuit potential (OCP) and electrochemical impedance spectroscopy (EIS) measurements. The use of an intermediate layer of poly(3‐octyl)thiophene between the gold substrate and the selective membrane was explored. SCISE prepared showing the best responses had typical DL, m, LR and RT values of 10?6 M, 29 mV/dec, 10?5 to 10?3 M and 2 minutes.  相似文献   

6.
《Electroanalysis》2003,15(19):1561-1565
A highly selective membrane electrode for the determination of ultratrace amounts of lead was prepared. The PVC membrane electrode based on 2‐(2‐ethanoloxymethyl)‐1‐hydroxy‐9,10‐anthraquinone (AQ), directly coated on graphite, exhibits a good Nernstian response for Pb(II) ions over a very wide concentration range (1.0×10?7–1.0×10?2 M) with a limit of detection of 8.0×10?8 M. It has a fast response time of ca. 10 s and can be used over a period 2 months with good reproducibility (SD=±0.2 mV). The electrode revealed a very good selectivity respect to common alkali, alkaline earth, transition and heavy metal ions and could be used in the pH range of 3.5–6.8. It was used as an indicator electrode in potentiometric titration of lead ions with chromate and oxalate, and in indirect determination of lead in spring water samples.  相似文献   

7.
《Electroanalysis》2004,16(4):282-288
Five recently synthesized macrocyclic diamides were investigated to characterize their ability as beryllium ion carriers in potentiometric PVC‐membrane electrodes. The electrodes based on 1,15‐diaza‐3,4;12,13‐dibenzo‐5,8,11‐trioxabicyclo[13,2,2] heptadecane‐2,14‐dione exhibited a Nernstian response for Be2+ ion over wide concentration ranges (from 3.0×10?6 to 3.0×10?2 M for polymeric membrane electrode, PME, and from 5.0×10?7 to 2.0×10?2 M for coated glassy carbon electrode, CGCE) and very low detection limits (2.0 ×10?6 M for PME and 4.0×10?7 M for (CGCE). The electrodes possess low resistances, fast responses, satisfactory reproducibilities and, most importantly, good selectivities relative to a variety of other common cations. The potentiometric response of the electrodes is independent of pH of test solution in the pH range of 4.0–7.5. The proposed sensors were used to determine beryllium ion in water samples.  相似文献   

8.
《Electroanalysis》2004,16(6):472-477
Five bisbridged calix[6]crowns have been investigated as Cs+ ionophore in PVC membrane electrodes. As ionophores, three 1,3‐bisbridged calix[6]crown‐4‐ethers( I–III ), 1,3‐bisbridged calix[6]crown‐5‐ether( IV ), and 1,3‐bisbridged calix[6]crown‐6‐ether( V ) have been evaluated. The membranes all give good Nernstian response in the concentration range from 1×10?7 to 1×10?1 M of cesium ion. The best detection limits (?log aequation/tex2gif-inf-1.gif=7.08–7.36) are obtained for electrode membranes containing 1,3‐bisbridged cofacial‐calix[6]crown‐4‐ethers( I‐III ), and the values are the lowest compared with those reported previously. The highest selectivity coefficients [ 3.74(Cs/K), 2.63(Cs/Rb)] are obtained for the membrane of 1,3‐bisbridged calix[6]crown‐4‐ether( II ), and these values are also the highest compared with previous reports for Cs+‐ISEs. The highest selectivity towards cesium ion is attributed to the geometrically cofacial positions of two crown‐ethers in calix[6]crowns in order to provide the complex of cesium ion and eight oxygens of cofacial crowns.  相似文献   

9.
《Electroanalysis》2003,15(19):1536-1540
The dynamic potential response of an 18‐crown‐6 based ion‐selective electrode towards Li+, Na+, K+ and Ca2+, in a flow‐injection system is studied. Different double nonmonotonic transient signals are obtained for the different ions. The influence of the flow‐injection variables and of ion concentration on the signals is studied. Two signal parameters, the relative return rates, are found to be characteristic for each ion and are constant for a concentration range of 1–3 decades. The nonmomotonic transient signals obtained are explained by reference to the theoretical models reported.  相似文献   

10.
《Electroanalysis》2002,14(24):1691-1698
Three different recently synthesized aza‐thioether crowns containing a 1,10‐phenanthroline sub‐unit (L1–L3) and a corresponding acyclic ligand (L4) were studied to characterize their abilities as silver ion ionophores in PVC‐membrane electrodes. Novel conventional silver‐selective electrodes with internal reference solution (CONISE) and coated graphite‐solid contact electrodes (SCISE) were prepared based on one of the 15‐membered crowns containing two donating S atoms and two phenanthroline‐N atoms (L1). The electrodes reveal a Nernstian behavior over wide Ag+ ion concentration ranges (1.0×10?5?1.0×10?1 M for CONISE and 5.0×10?8?4.0×10?2 M for SCISE) and very low limits of detection (8.0×10?6 M for CONISE and 3.0×10?8 M for SCISE). The potentiometric response is independent from pH of the solution in the pH range 3.0–8.0. The electrodes manifest advantages of low resistance, very fast response and, most importantly, good selectivities relative to a wide variety of other cations. The electrodes can be used for at least 2 months (for CONISE) and 4 months for (SCISE) without any appreciable divergence in potentials. The electrodes were used as an indicator electrode in the potentiometric titration of Ag+ ion and in the determination of silver in photographic emulsions and in radiographic and photographic films.  相似文献   

11.
《Analytical letters》2012,45(13):2269-2279
Abstract

A lead ion-selective electrode based on dibenzopyridino-18-crown-6 as membrane carrier was successfully prepared. The electrode exhibits a Nernstian response for Pb2+ ions over a wide concentration range. Influences of the nature of plasticizer, the concentrations of internal solutions in the electrodes and the composition of the membrane were investigated. The lead ion-selective electrode exhibited comparatively good selectivities with respect to alkali, alkaline earth and some transition and heavy metal ions.  相似文献   

12.
Until now both ion‐to‐electron transducers as well as large surface area nanostructured conducting materials were successfully used as solid contacts for polymer‐based ion‐selective electrodes. We were interested to explore the combination of these two approaches by fabricating ordered electrically conducting polymer (ECP) nanostructures using 3D nanosphere lithography and electrosynthesis to provide a high surface area and capacitive interface for solid contact ion‐selective electrodes (SC‐ISEs). For these studies we used poly(3,4‐ethylenedioxythiophene)/poly(styrenesulfonate) (PEDOT(PSS)) films with 750 nm diameter interconnected pores as the intermediate layer between a glassy carbon electrode and a Ag+ ‐selective polymeric membrane. We also investigated the feasibility of loading the voids created in the polymer film with a lipophilic redox mediator (1,1’‐dimethylferrocene) to provide the respective ISEs with well‐defined/controllable E0 values. These expectations were fulfilled as the standard deviation of E0 values were reduced with almost an order of magnitude for 3D nanostructured SC‐ISEs filled with the redox mediator as compared to their redox mediator‐free analogs. The detrimental effect of the redox mediator extraction into the plasticized PVC‐based ion‐selective membrane (ISM) was efficiently suppressed by replacing the PVC‐based ISMs with a low diffusivity silicone rubber matrix.  相似文献   

13.
《Electroanalysis》2005,17(9):776-782
Three recently synthesized Schiff's bases were studied to characterize their ability as Cr3+ ion carrier in PVC‐membrane electrodes. The polymeric membrane (PME) and coated glassy carbon (CGCE) electrodes based on 2‐hydroxybenzaldehyde‐O,O′‐(1,2‐dioxetane‐1,2‐diyl) oxime (L1) exhibited Nernstian responses for Cr3+ ion over wide concentration ranges (1.5×10?6–8.0×10?3 M for PME and 4.0×10?7–3.0×10?3 M for CGCE) and very low limits of detection (1.0×10?6 M for PME and 2.0×10?7 M for CGCE). The proposed potentiometric sensors manifest advantages of relatively fast response and, most importantly, good selectivities relative to a wide variety of other cations. The selectivity behavior of the proposed Cr3+ ion‐selective electrodes revealed a considerable improvement compared to the best previously PVC‐membrane electrodes for chromium(III) ion. The potentiometric responses of the electrodes are independent of pH of the test solution in the pH range 3.0–6.0. The electrodes were successfully applied to determine chromium(III) in water samples.  相似文献   

14.
A highly selective PVC membrane electrode for Al3+ based on salicylaldehyde salicyloyl hydrazone as a neutral carrier has been prepared and studied. The sensor exhibits a good response for Al3+ over a linear range of 9.0 × 10‐6 to 1.0 × 10‐1 mol/L, with a Nernstian slope of 20.0 ± 0.2 mV/decade and detection limit of 7.0 × 10‐6 mol/L. Selectivity coefficients determined by the method of separate solution indicate high selectivity for Al3+. The response mechanism was discussed in view of UV‐Vis spectroscopy technique and the A.C. impedance technique. It was used as an indicator electrode in potentiometric titration of Al3+ with EDTA and in the determination of Al3+ in real samples. The electrode has a relatively fast response time, long life time and satisfactory stability.  相似文献   

15.
Selectivity of electromembrane extractions (EMEs) was fine‐tuned by modifications of supported liquid membrane (SLM) composition using additions of various 18‐crown‐6 ethers into 1‐ethyl‐2‐nitrobenzene. Gradually increased transfer of K+, the cation that perfectly fits the cavity of 18‐crown‐6 ethers, was observed for EMEs across SLMs modified with increasing concentrations of 18‐crown‐6 ethers. A SLM containing 1% w/v of dibenzo‐18‐crown‐6 in 1‐ethyl‐2‐nitrobenzene exhibited excellent selectivity for EMEs of K+. The established host–guest interactions between crown ether cavities in the SLM and potassium ions in donor solution ensured their almost exhaustive transfer into acceptor solution (extraction recovery ~92%) within 30 min of EME at 50 V. Other inorganic cations were not transferred across the SLM (Ca2+ and Mg2+) or were transferred negligibly (NH4+, Na+; extraction recovery < 2%) and had only subtle effect on EMEs of K+. The high selectivity of the tailor‐made SLM holds a great promise for future applications in EMEs since the range of similar selective modifiers is very broad and may be applied in various fields of analytical chemistry.  相似文献   

16.
《Electroanalysis》2005,17(8):648-654
5‐[((4‐Methyl phenyl) azo)‐N‐(6‐amino‐2‐pyridin) salicylaldimine] (S1), and 5‐[((4‐methyl phenyl) azo)‐N‐(2‐diamino‐2‐cyano‐1‐ethyl cyanide) salicylaldehyde] (S2) with N and O donor atoms are effective ionophores to make Cd2+‐selective membrane electrodes. The electrodes based on S1 and S2 exhibits a Nernstian or near‐Nernstian response for cadmium ion over a wide concentration range 1.5×10?1–7.5×10?7 with a slope of 28 and 2.0×10?1–4.0×10?7 with a slope of 22, respectively. They have quick response and can be used for three or four months without any divergence in potential. The proposed sensors show fairly good selectivity over some alkali, alkaline earth, transition and heavy metal ions. The electrodes based on S1 and S2 can be used in the pH range 3.5–9. These electrodes were used as an indicator electrode in potentiometric titration of cadmium ion with EDTA and in the direct determination of cadmium ion in aqueous solutions.  相似文献   

17.
Two diaza-crown ether compounds were synthesized and evaluated as Ag+-selective carriers in polyvinylchloride (PVC) membrane electrodes of solid-state type. The all-solid-state PVC membrane electrode based on N,N-Dibenzyl-dibenzo-diaza-18-crown-6 exhibited a super-Nernstian response (75±10mV per decade) over the concentration range of 1×10–1 to 7×10–6M of Ag+ ion and a detection limit of 3×10–6M, at a wide range of pH (pH 4–7). The response time of the electrode was fast (less than 10s), and it can be used for three months without any significant deviation in potential. The proposed all-solid-state PVC membrane electrodes revealed high selectivity toward Ag+ ion with respect to alkali, alkaline earth, heavy and transition metal ions. A flow-through cell of all-solid-state PVC membrane Ag+-selective electrode based on N,N-Dibenzyl-dibenzo-diaza-18-crown-6 has also been prepared and applied for flow-injection analysis of Ag+ ion in solution.  相似文献   

18.
A PVC membrane electrode for lead ions based on 5,5′-dithiobis-(2-nitrobenzoic acid) as membrane carrier was prepared. The electrode exhibits a Nernstian response for Pb2+ over a wide concentration range (1.0×10−2–4.0×10−6 M). It has a relatively fast response time and can be used for at least 3 months without any divergence in potentials. The proposed electrode revealed good selectivities for Pb2+ over a wide variety of other metal ions and could be used in a pH range of 2.0–7.0. It was used as an indicator electrode in potentiometric titration of lead ions and in direct determination of lead in water samples.  相似文献   

19.
《Electroanalysis》2006,18(8):763-771
A novel concept of tailoring potentiometric responses of all‐solid‐state ion‐selective electrodes was introduced. The effect of composition and resulting properties of the conjugated polymer transducer, placed between the electrode support and ion‐selective membrane, on analytical characteristic of obtained sensors was studied.  相似文献   

20.
New polymeric membrane cadmium‐ion selective sensors have been prepared by incorporating nitrogen and sulfur containing tridentate ligands as the ionophores into the plasticized PVC membranes. Poly(vinyl chloride) (PVC) based membranes of potassium hydrotris[N‐(2,6‐xylyl)thioimdazolyl) borate] (KTt2,6‐xylyl) and potassium hydrotris(3‐phenyl‐5‐methylpyrazolyl) borate (KTpPh,Me) with sodium tetraphenyl borate (NaTPB) as an anionic excluder and dibutylphthalate (DBP), tributylphthalate (TBP), dioctylsebacate (DOS), and o‐nitrophenyloctyl ether (o‐NPOE) as plasticizing solvent mediators were investigated in different compositions. KTt2,6‐xylyl was found to be a selective and sensitive ion carrier for Cd(II) membrane sensor. A membrane composed of KTt2,6‐xylyl:NaTPB:PVC:DBP with the % mole ratio 2.3 : 1.1 : 34.8 : 61.8 (w/w) works well over a very wide concentration range (7.8×10?8–1.0×10?2 M) with a Nernstian slope of 29.4±0.2 mV/decades of activity between pH values of 3.5 to 9.0 with a detection limit of 4.37×10?8 M. The sensor displays very good discrimination toward Cd(II) ions with regard to most common cations. The proposed sensor shows a short response time for whole concentration range (ca. 8 s). The effects of the cationic (tetrabutylammonium chloride, TBC), anionic (sodium dodecyl sulfate, SDS) and nonionic (Triton X‐100) surfactants were investigated on the potentiometric properties of proposed cadmium‐selective sensor. The proposed sensor based on KTt2,6‐xylyl ionophore has also been used for the direct determination of cadmium ions in different water samples and human urine samples.  相似文献   