首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An on-line solid-phase extraction liquid chromatography/tandem mass spectrometry (SPE LC/MS/MS) assay using a newly developed SPE column and a monolithic column was developed and validated for direct analysis of plasma samples containing multiple analytes. This assay was developed in an effort to increase bioanalysis throughput and reduce the complexity of on-line SPE LC/MS/MS systems. A simple column-switching configuration that requires only one six-port valve and one HPLC pumping system was employed for on-line plasma sample preparation and subsequent gradient chromatographic separation. The resulting analytical method couples the desired sensitivity with ease of use. The method was found to perform satisfactorily for direct plasma analysis with respect to assay linearity, specificity, sensitivity, precision, accuracy, carryover, and short-term stability of an eight-analyte mixture in plasma. A gradient LC condition was applied to separate the eight analytes that cannot be distinctly differentiated by MS/MS. With a run time for every injection of 2.8 min, a minimum of 300 direct plasma injections were made on one on-line SPE column without noticeable changes in system performance. Due to the ruggedness and simplicity of this system, generic methods can be easily developed and applied to analyze a wide variety of compounds in a high-throughput manner without laborious off-line sample preparation.  相似文献   

2.
采用自动前处理LC/MS进行血浆中药物的快速分析   总被引:3,自引:0,他引:3  
药物研究的发展对高通量的样品处理分析提出了越来越高的要求,减少样品制备时间和分析时间是解决问题的关键。我们新近发展了一种具有在线稀释旁路和新的样品预处理柱的Shim-Pack MAYI-ODS自动柱切换HPLC和LC/MS系统,该系统无需样品前处理,可直接进样进行血浆、血清中的药物分析。本文利用自动样品前处理LC/MS系统,用ODS整体柱实现了血浆中药物的快速分析。包括样品预处理,整个分析仅需1.2min完成。  相似文献   

3.
High-throughput quantitative bioanalysis by LC/MS/MS   总被引:8,自引:0,他引:8  
This review article discusses the most recent significant advances in the sample preparation and mass spectrometry aspects of high-throughput bioanalysis by LC/MS/MS for the quantitation of drugs, metabolites and endogenous biomolecules in biological matrices. The introduction and implementation of automated 96-well extraction has brought about high-throughput approaches to the biological sample preparation techniques of solid-phase extraction, liquid-liquid extraction and protein precipitation. The fast-flow on-line extraction technique is a different high-throughput approach that has also significantly speeded up analysis by LC/MS/MS. The use of pierceable caps for biological tubes further enhances the analysis speed and improves the safety in handling biological samples. The need for adequate chromatographic separation in order to eliminate interferences due to metabolites and/or matrix effects in LC/MS/MS is discussed. To highlight our limited understanding of atmospheric pressure ionization mass spectrometry, results from recent investigations that appear to be counter-intuitive are presented. Looking ahead to the future, multiplexed LC/MS/MS systems and capillary LC are presented as areas that can bring about further improvements in analysis speed and sensitivity to quantitative bioanalysis by LC/MS/MS.  相似文献   

4.
As a continuation of our efforts to improve our high-flow on-line bioanalytical approach for high-throughput quantitation of drugs and metabolites in biological matrices by high-performance liquid chromatography (LC) and tandem mass spectrometry (MS/MS), we have developed a ternary-column on-line LC/MS/MS system with dual extraction columns used in parallel for purification and an analytical column for analysis. The advantage of the dual extraction column system is that sample analysis can take place in one of the extraction columns while the other column is being equilibrated. Thus, the equilibration time does not add to the run time, hence shortening the injection cycle time and increasing the sample throughput. Moreover, the use of two extraction columns in parallel increases the number of samples that can be injected before the system fails due to an overused extraction column. Such a system has successfully been used to develop and validate a positive ion electrospray LC/MS/MS bioanalytical method for the quantitative determination of a guanidine-containing drug candidate in rat plasma. The system used for this work utilized two Oasis HLB extraction columns (1 x 50 mm, 30 microm), one C18 analytical column (3.9 x 50 mm, 5 microm), a ten-port switching value and a tandem mass spectrometer. The on-line analysis was accomplished by the direct injection of 10 microL of the sample, obtained by mixing a rat plasma sample 1:1 with an aqueous internal standard solution. Selected reaction monitoring (SRM) was utilized for the detection of the analyte and internal standard. The standard curve range was 1.00-200 ng/mL. The intra- and inter-day precision and accuracy were within 6.6%. The on-line purification step lasted for only 0.3 min and total run time was only 1.6 min.  相似文献   

5.
In drug discovery today, drug exposure is determined in preclinical efficacy and safety studies and drug effects are related to measured concentrations rather than to the administered dose. This leads to a strong increase in the number of bioanalytical samples, demanding the development of higher throughput methods to cope with the increased workload. Here, a combined approach is described for the high-throughput preparation and liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis of drug levels in plasma samples from the preclinical efficacy and safety studies, i.e. exposure studies. Appropriate pharmacokinetic (PK) compartmental models were fitted to data from PK screening studies in the rat, which were subsequently used to simulate the expected plasma concentrations of the respective exposure studies. Information on the estimated drug concentrations was used to dilute the samples to appropriate concentration levels. A Tecan Genesis RSP liquid handling system was utilized to perform automated plasma sample preparation including serial dilution of standard solutions, dilution of plasma samples, addition of internal standard solution and precipitation with acetonitrile. This robotic sample preparation process permitted two studies of 1-96 samples each to be run simultaneously. To ensure the performance of this method the accuracy and precision for diazepam were examined. Two novel drugs were used to illustrate the suggested approach. In conclusion, our method for sample preparation of exposure samples, based on the combined use of PK simulations, a liquid handling system and a fast LC/MS/MS method, increased the throughput more than three times and minimized the errors, while maintaining the required accuracy and precision.  相似文献   

6.
The goal of this work was to evaluate the improvement in proteome coverage of complex protein mixtures gained by analyzing samples using both LC/ESI/MS/MS and LC/MALDI/MS/MS. Parallel analyses of a single sample were accomplished by interfacing a Probot fractionation system with a nanoscale LC system. The Probot was configured to perform a post-column split such that a fraction (20%) of the column effluent was sent for on-line LC/ESI/MS/MS data acquisition, and the majority of the sample (80%) was mixed with a matrix solution and deposited onto the MALDI target plate. The split-flow approach takes advantage of the concentration sensitive nature of ESI and provides sufficient quantity of sample for MALDI/MS/MS. Hybrid quadrupole time-of-flight mass spectrometers were used to acquire LC/ESI/MS/MS data and LC/MALDI/MS/MS data from a tryptic digest of a preparation of mammalian mitochondrial ribosomes. The mass spectrometers were configured to operate in a data dependent acquisition mode in which precursor ions observed in MS survey scans are automatically selected for interrogation by MS/MS. This type of acquisition scheme maximizes the number of peptide fragmentation spectra obtained and is commonly referred to as shotgun analysis. While a significant degree of overlap (63%) was observed between the proteins identified in the LC/ESI/MS/MS and LC/MALDI/MS/MS data sets, both unique peptides and unique proteins were observed by each method. These results demonstrate that improved proteome coverage can be obtained using a combination of these ionization techniques.  相似文献   

7.
Direct injection versus liquid-liquid extraction for post-dose human plasma sample analysis by high performance liquid chromatography with tandem mass spectrometry (LC/MS/MS) have been studied using a drug candidate compound. For the direct-injection method, an Oasis(R) HLB column (1 x 50 mm, 30 micrometer) was used as the on-line extraction column and a conventional Waters symmetry C18 column (3.9 x 50 mm, 5 micrometer) was used as the analytical column. Each plasma sample (100 microL) was mixed with 100 microL of a working solution of the internal standard in aqueous 0.05 M ammonium acetate (pH 6.9), and portions (10 microL) of these samples were then injected into the LC/MS/MS system. For the liquid-liquid extraction method, a YMC Basic C18 column (2.0 x 50 mm, 5 micrometer) was used as the analytical column. Each sample (0.5 mL) was extracted with methyl tert-butyl ether and the extract was reconstituted and injected into the LC/MS/MS system. The total analysis time for both methods was 2.0 min per sample. The accuracy, inter-day precision and intra-day precision obtained from the quality control samples were within 8% for both methods. The analysis results of post-dose human plasma samples showed that the deviations of 91% of the concentrations obtained using the direct-injection method were within +/-20% from the concentrations obtained using the liquid-liquid extraction method, and the overall average percentage deviation was -1.5%. The results showed that the two methods were equivalent in terms of total chromatographic run time, accuracy and precision. However, for a batch of 100 samples, the sample preparation time for the direct-injection method was only about 25% of the time required for liquid-liquid extraction. This decrease in sample preparation time resulted in the doubling of the overall sample analysis throughput.  相似文献   

8.
This report addresses the continuing need for increased throughput in the evaluation of new chemical entities (NCEs) in terms of their pharmacokinetic (PK) parameters by describing an alternative procedure for increasing the throughput of the in vivo screening of NCEs in the oral rat PK model. The new approach is called "cassette-accelerated rapid rat screen" (CARRS). In this assay, NCEs are dosed individually (n = 2 rats/compound) in batches of six compounds per set. The assay makes use of a semi-automated protein precipitation procedure for sample preparation in a 96-well plate format. The liquid chromatography/atmospheric pressure ionization tandem mass spectrometry (LC/API-MS/MS) assay is also streamlined by analyzing the samples as "cassettes of six". Using this new approach, a threefold increase in throughput was achieved over the previously reported "rapid rat screen".  相似文献   

9.
A new method based on matrix solid-phase dispersion (MSPD) on-line with a solid-phase extraction (SPE) cleanup process followed by liquid chromatography with tandem mass spectrometry (LC/MS/MS) is presented for the determination of 3 macrocyclic lactone mycotoxins in fish tissues: zearalenone, alpha-zearalenol, and beta-zearalenol. The sample was prepared in a device that used a reversed-phase material (C18) or a normal-phase material (neutral alumina) as a matrix dispersing agent, and a graphitized carbon black cartridge was used for sequential cleanup by SPE. LC/MS/MS was used for selective determination. Isocratic elution with acetonitrile-methanol-water was used for LC separation; for MS/MS, 2 types of interfaces (a pneumatically assisted electrospray ionization interface or an atmospheric pressure chemical ionization interface) were evaluated and compared in terms of the intensity of the total ion current produced by each analyte. The use of highly selective MSPD on-line with SPE for sample preparation before analysis allowed the removal of interfering matrix compounds present in tissue extracts that would otherwise cause severe ionization suppression of zearalenone and its metabolites during the ionization process. Average recoveries at 100 ng/g were between 83 and 103% with C18 and > or = 67% with neutral alumina; the relative standard deviations were < 11% with C18 and < 18% with alumina. The limits of detection ranged from 0.1 to 1.0 ng/g. Sample preparation is simple to perform, no special technical equipment is required, and solvent volumes are minimal.  相似文献   

10.
The preparation of protein substrates requires that a large number of chromatographic fractions be analyzed for the presence of reactants, products and by-products. Analyses using linear matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) or single column liquid chromatography/mass spectrometry (LC/MS) have been inadequate because of mass resolution or throughput. Therefore, a high-throughput method employing an eight-channel parallel reverse-phase LC/MS system was developed. This system is capable of screening fractions from preparative ion-exchange chromatography with the required mass accuracy and throughput so that the protein purification process can be monitored in a relatively short period of time. As an example, the purification and analysis of an acylated protein with a molecular weight of 8.9 kDa is described and the detection of a contaminating by-product that differs in size by less than 20 Da is demonstrated. Using the current instrumentation and approach, it is practical to analyze 50 protein-containing fractions from column chromatography in less than 1 hour using parallel LC/MS.  相似文献   

11.
The applicability of liquid chromatography–mass spectrometry (LC/MS) is often limited by throughput. The sharing of a mass spectrometer with multiple LCs significantly improves throughput; however, the reported systems have not been designed to fully utilize the MS duty cycle, and as a result to achieve maximum throughput. To fully utilize the mass spectrometer, the number of LC units that a MS will need to recruit is application dependent and could be significantly larger than the current commercial or published implementations. For the example of a single analyte, the number may approach the peak capacity to a first degree approximation. Here, the construction of a MS system that flexibly recruits any number of LC units demanded by the application is discussed, followed by the method to port a previously developed LC/MS method to the system to fully utilize a mass spectrometer. To demonstrate the performance and operation, a prototypical MS system of eight LC units was constructed. When 1‐min chromatographic separations were performed in parallel on the eight LCs of the system, the average LC/MS analysis time per sample was 10.5 s when applied to the analysis of samples in 384‐well plate format. This system has been successfully used to conduct large‐volume biochemical assays with the analysis of a variety of molecular entities in support of drug discovery efforts. Allowing the recruitment of the number of LC units appropriate for a given application, this system has the potential to be a plug‐and‐play system to fully utilize a mass spectrometer. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

12.
Liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been coupled to in vivo microdialysis for on-line monitoring of melatonin in a freely moving rat for a period of 15 hours. A microdialysis probe was surgically implanted into the jugular vein of the rat, and deionized water was used as the perfusion medium at a flow rate of 1.0 microL/min. Microdialysis samples were collected in an on-line injector with sample injection every 30 minutes. Melatonin was dosed by intraperitoneal (i.p.) injection and then monitored by microdialysis/LC/MS/MS. The whole experiment, including the microdialysis sampling and sample injection into the LC/MS system, was fully automated. Metabolites of melatonin were identified off-line by LC/MSn experiments. Two metabolites were identified as 6-hydroxymelatonin and cyclic 2-hydroxymelatonin, consistent with ones found previously in the literature.  相似文献   

13.
Recent years have seen increasing usage of large particle size stationary phases and ultra-high flow rate liquid chromatography/mass spectrometry (LC/MS) for rapid determination of pharmaceuticals in plasma without prior sample preparation. This lack of sample preparation prior to analysis, together with the extremely high throughput of the chromatography, makes the technique extremely attractive to the bioanalyst. Further, the introduction of multiple sprayer interfaces to mass spectrometers provides the potential for even higher throughput. In this paper, we present parallel ultra-high flow rate liquid chromatography using four columns in parallel and a four-way multiple sprayer interface to the mass spectrometer. We have applied this on both the narrow-bore and capillary scale. This technique enables the quantification of drugs from four plasma samples simultaneously, at nanogram per millilitre concentrations, from small aliquots of plasma without sample preparation and with throughputs of up to 120 samples per hour.  相似文献   

14.
A method with parallel extraction columns and parallel analytical columns (PEC-PAC) for on-line high-flow liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and validated for simultaneous quantification of a drug candidate and its six metabolites in dog plasma. Two on-line extraction columns were used in parallel for sample extraction and two analytical columns were used in parallel for separation and analysis. The plasma samples, after addition of an internal standard solution, were directly injected onto the PEC-PAC system for purification and analysis. This method allowed the use of one of the extraction columns for analyte purification while the other was being equilibrated. Similarly, one of the analytical columns was employed to separate the analytes while the other was undergoing equilibration. Therefore, the time needed for re-conditioning both extraction and analytical columns was not added to the total analysis time, which resulted in a shorter run time and higher throughput. Moreover, the on-line column extraction LC/MS/MS method made it possible to extract and analyze all seven analytes simultaneously with good precision and accuracy despite their chemical class diversity that included primary, secondary and tertiary amines, an alcohol, an aldehyde and a carboxylic acid. The method was validated with the standard curve ranging from 5.00 to 5000 ng/mL. The intra- and inter-day precision was no more than 8% CV and the assay accuracy was between 95 and 107%.  相似文献   

15.
Studying the permeability of compounds across a Caco-2 cell monolayer is an established in vitro model to screen for oral absorption and to evaluate the mechanism of transport. This assay can also be used to evaluate compounds as potential P-glycoprotein substrates and/or inhibitors. The traditional methods of sample analysis (high-performance liquid chromatography (HPLC) with a UV or fluorescence detector) limit the throughput and sensitivity of this assay. Data are presented here describing the use of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the analysis of samples derived from the Caco-2 cell studies. During the analysis an automatic switching valve was used to divert the flow from the HPLC column to waste for the first minute, preventing the early eluting salts from entering and contaminating the LC/MS interface. This approach allows the rapid and accurate determination of drug transport across the Caco-2 cell monolayer. The high sensitivity and specificity of LC/MS/MS make this technique an ideal candidate for the low concentration and high throughput routine analysis of Caco-2 cell solutions, especially if multiple compounds are administered and analyzed simultaneously. Thus, the use of LC/MS/MS will increase the value of the Caco-2 cell assay as an in vitro screening tool.  相似文献   

16.
The development of a simple and sensitive assay for the quantitative analysis of the marine anticancer agent Yondelis (ET-743, trabectedin) in human plasma using liquid chromatography (LC) with column switching and tandem mass spectrometric (MS/MS) detection is described. After protein precipitation with methanol, diluted extracts were injected on to a small LC column (10 x 3.0 mm i.d.) for on-line concentration and further clean-up of the sample. Next, the analyte and deuterated internal standard were back-flushed on to an analytical column for separation and subsequent detection in an API 2000 triple-quadrupole mass spectrometer. The lower limit of quantitation was 0.05 ng mL(-1) using 100 micro l of plasma with a linear dynamic range up to 2.5 ng ml(-1). Validation of the method was performed according to the most recent FDA guidelines for bioanalytical method validation. The time needed for off-line sample preparation has been reduced 10-fold compared with an existing LC/MS/MS method for ET-743 in human plasma, employing a labor-intensive solid-phase extraction procedure for sample pretreatment. The proposed column switching method was successfully applied in phase II clinical trials with Yondelis and pharmacokinetic monitoring.  相似文献   

17.
Ginkgo biloba (ginkgo) is one of most frequently used botanical dietary supplements. The bioactive constituents include the terpenoid lactones consisting of bilobalide and the ginkgolides A, B, C and J. A new assay based on high-performance liquid chromatography/electrospray tandem mass spectrometry (LC/MS/MS) was developed for the measurement of the terpenoid lactones in ginkgo products such as leaf powder and extracts. Initially, the MS/MS fragmentation pathways of ginkgolides were investigated to identify abundant fragment ions that might be useful for the sensitive and selective detection of ginkgolides and bilobalide during LC/MS/MS. Then, sample preparation and clean-up procedures were streamlined to maximize throughput by taking advantage of the selectivity of LC/MS/MS detection. Analyte recoveries exceeded 90%, the intra-assay and inter-assay relative standard deviations were <5%, the relative error was <8% and the limits of detection and quantification were 3.6-120 and 11-350 fmol, depending on the analyte that was injected on to the LC column. Therefore, this LC/MS/MS assay facilitated the rapid quantitative analysis of ginkgolides A, B, C and J and bilobalide in ginkgo dietary supplements with excellent recovery, reproducibity, accuracy and sensitivity.  相似文献   

18.
Levosimendan (Simdax) is an approved drug in approximately 40 countries and currently in phase III clinical studies in the USA and Europe. An accurate, high-throughput and rugged assay is critical to support these clinical trials. Due to the mechanism of drug metabolism, the drug and its active metabolites often have significant differences in their chemical properties. In order to achieve high assay throughput and low sample volumes, a single bioanalytical assay for the drug and its metabolites is preferred. However, this need may prevent the optimization of both high-performance liquid chromatography (HPLC) and mass spectrometric ionization conditions. The chemical properties of levosimendan are significantly different from those of its two active metabolites, OR-1855 and OR-1896. Here, we present a novel strategy for high-throughput analysis of levosimendan and its metabolites. A 96-well liquid/liquid extraction procedure was developed for sample preparation. A single liquid chromatography/tandem mass spectrometry (LC/MS/MS) system with two separate mobile phases, shared backwash solvent and conditioning solvent, was developed to perform sequential LC separation for levosimendan and the metabolites. Levosimendan was eluted by 5 mM ammonium acetate in 33.3% acetonitrile and detected using negative ionization mode MS/MS monitoring. The metabolites were eluted by 5 mM ammonium acetate and 0.2% acetic acid in 20% acetonitrile and detected with positive ionization mode MS/MS monitoring. The method has been demonstrated to have excellent precision and accuracy, with high assay ruggedness during method validation and clinical sample analysis. The linear dynamic ranges were approximately 200-50,000 pg/mL for levosimendan and approximately 500-130,000 pg/mL for both metabolites. The coefficient of determination (r2) for all analytes was greater than 0.9985. The intra-assay %CVs for QC samples were from 0.9% to 2.0% for levosimendan, 0.9% to 3.2% for OR-1855, and 0.4% to 4.9% for OR-1896. The inter-assay %CVs for QC samples were from 1.2% to 1.8% for levosimendan, 1.3% to 2.7% for OR-1855, and 1.4% to 3.4% for OR-1896. The mean % biases for QC samples were from 1.5% to 5.5% for levosimendan, -1.4% to 2.6% for OR-1855, and -0.3% to 4.5% for OR-1896. By using a single extraction approach coupled with sequential LC/MS/MS analysis for levosimendan and its metabolites, the assay maintained high throughput and low sample volume usage.  相似文献   

19.
Iralukast (CGP 45715A) is a potent peptido-leukotriene antagonist that is active in various in vitro and animal models for the treatment of asthma. An analytical challenge was to develop a sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method with a lower limit of quantitation (LLOQ) of 10 pg/mL for the analysis of iralukast when administered at low doses during clinical trials. Several issues had to be addressed in order to devise a LC/MS/MS assay for the above compound. First, iralukast appeared to be light sensitive and unstable at room temperature under acidic conditions. Second, a LLOQ of 10 pg/mL was needed to support several clinical trials. Third, positive electrospray ionization of iralukast did not yield the necessary sensitivity required for studies in humans. Consequently, LC/MS/MS conditions were optimized for the negative ion mode of detection. Fourth, sample preparation steps proved to be critical to reduce the possibility of microbore HPLC column (50 mm x 1.0 mm i.d.) obstruction, chromatographic deterioration, and matrix-mediated electrospray ion suppression. While our validated method addressed the above challenges, its major drawback was limited sample throughput capability. Nonetheless, plasma concentration-time profiles for patients with moderate asthma after oral administration of 200, 500, 1000, and 5000 microgram/kg/day of iralukast were successfully obtained.  相似文献   

20.
A simple procedure for sample preparation of human plasma by two stages of ultrafiltration using one device is described. Our approach is useful for nondigest liberation of biomarkers bound to albumin and other plasma proteins. The analyte contained in the ultrafiltrate can be directly analyzed without additional sample preparation, and quantified by 2-D RP-RP LC/MS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号