首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
A simple method for the analysis of capsaicin and dihydrocapsaicin in peppers and pepper sauces by solid phase microextraction–gas chromatography–mass spectrometry has been developed. A novel device was designed for direct extraction solid phase microextraction in order to avoid damage to the fiber. The analysis was performed without derivatization for the gas chromatography–mass spectrometry analysis. Selection fiber, extraction temperature, extraction time and pH, were optimized. The method was linear in the range 0.109–1.323 μg/mL for capsaicin and 0.107–1.713 μg/mL for dihydrocapsaicin with correlation coefficient up to r = 0.9970 for both capsaicinoids. The precision of the method was less than 10%. The method was applied to the analysis of 11 varieties of peppers and four pepper sauces. A broad range of capsaicin (55.0–25 459 μg/g) and dihydrocapsaicin (93–1 130 μg/g) was found in the pepper and pepper sauces samples (4.3–717.3 and 1.0–134.8 μg/g), respectively.  相似文献   

3.
A method based on gas chromatography-mass spectrometry analysis of acetylated methyl glycosides was developed in order to analyze monosaccharides obtained from various hemicelluloses. The derivatives of monosaccharide standards, arabinose, glucose, and xylose were studied in detail and (13)C-labeled analogues were used for identification and quantitative analysis. Excellent chromatographic separation of the monosaccharide derivatives was found and identification of the anomeric configuration was feasible through a prepared and identified pure methyl 2,3,4,6-tetra-O-acetyl-β-D-glucopyranoside. The electron ionization mass spectrum and fragmentation path was studied for each monosaccharide derivative. Fragment ion pairs of labeled and unlabeled monosaccharides were used for quantification; m/z 243/248 for glucose, 128/132 for xylose, and 217/218 for arabinose. Using the intensity ratios obtained from the extracted ion chromatograms, accurate quantification of monosaccharide constituents of selected hemicelluloses was demonstrated.  相似文献   

4.
Benzene is classified as a Group I carcinogen by the International Agency for Research on Cancer (IARC). The risk assessment for benzene can be performed by monitoring environmental and occupational air, as well as biological monitoring through biomarkers. The present work developed and validated methods for benzene analysis by GC/MS using SPME as the sampling technique for ambient air and breath. The results of the analysis of air in parks and avenues demonstrated a significant difference, with average values of 4.05 and 18.26 μg m−3, respectively, for benzene. Sampling of air in the occupational environment furnished an average of 3.41 and 39.81 μg m−3. Moreover, the correlations between ambient air and expired air showed a significant tendency to linearity (R 2 = 0.850 and R 2 = 0.879). The results obtained for two groups of employees (31.91 and 72.62 μg m−3) presented the same trend as that from the analysis of environmental air.  相似文献   

5.
In this publication, a novel solid phase microextraction (SPME) coating functionalized with a DNA aptamer for selective enrichment of a low abundance protein from diluted human plasma is described. This approach is based on the covalent immobilization of an aptamer ligand on electrospun microfibers made with the hydrophilic polymer poly(acrylonitrile-co-maleic acid) (PANCMA) on stainless steel rods. A plasma protein, human α-thrombin, was employed as a model protein for selective extraction by the developed Apt-SPME probe, and the detection was carried out with liquid chromatography/tandem mass spectrometry (LC–MS/MS). The SPME probe exhibited highly selective capture, good binding capacity, high stability and good repeatability for the extraction of thrombin. The protein selective probe was employed for direct extraction of thrombin from 20-fold diluted human plasma samples without any other purification. The Apt-SPME method coupled with LC–MS/MS provided a good linear dynamic range of 0.5–50 nM in diluted human plasma with a good correlation coefficient (R2 = 0.9923), and the detection limit of the proposed method was found to be 0.30 nM. Finally, the Apt-SPME coupled with LC–MS/MS method was successfully utilized for the determination of thrombin in clinical human plasma samples. One shortcoming of the method is its reduced efficiency in undiluted human plasma compared to the standard solution. Nevertheless, this new aptamer affinity-based SPME probe opens up the possibility of selective enrichment of a given targeted protein from complex sample either in vivo or ex vivo.  相似文献   

6.
A method for the determination of organotin compounds (monobutyl = MBT, dibutyl = DBT, and tributyltin = TBT) in marine sediments by headspace Solid Phase Microextraction (SPME) has been developed. The analytical procedure involved 1) extraction of TBT, DBT and MBT from sediments with HCl and methanol mixture, 2) in situ derivatization with sodium tetraethylborate and 3) headspace SPME extraction using a fiber coated with poly(dimethylsiloxane). The derivatized organotin compounds were desorbed into the splitless injector and simultaneously analyzed by gas chromatography – mass spectrometry. The analytical method was optimized with respect to derivatization reaction and extraction conditions. The detection limits obtained for MBT, DBT and TBT ranged from 730 to 969 pg/g as Sn dry weight. Linear calibration curves were obtained for all analytes in the range of 30–1000 ng/L as Sn. Analysis of a standard reference sediment (CRM 462) demonstrates the suitability of this method for the determination of butyltin compounds in marine sediments. The application to the determination of TBT, DBT and MBT in a coastal marine sediment is shown.  相似文献   

7.
A fully automated method using direct immersion solid-phase microextraction (DI-SPME) and headspace on-fiber silylation for simultaneous determinations of exogenous endocrine-disrupting chemicals (EDCs) and endogenous steroid hormones in environmental aqueous and biological samples by gas chromatography–mass spectrometry (GC-MS) was developed and compared to a previously reported manual method. Three EDCs and five endocrine steroid hormones were selected to evaluate this method. The extraction and derivatization time, ion strength, pH, incubation temperature, sample volume, and extraction solvent were optimized. Satisfactory results in pure water were obtained in terms of linearity of calibration curve (R 2=0.9932–1.0000), dynamic range (3 orders of magnitude), precision (4–9% RSD), as well as LOD (0.001–0.124 μg L−1) and LOQ (0.004–0.413 μg L−1), respectively. These results were similar to those obtained using a manual method, and moreover, the precision was improved. This new automated method has been applied to the determinations of target compounds in real samples used in our previous study on a manual SPME method. Exogenous octylphenol (OP), technical grade nonylphenol (t-NP), and diethylstilbestrol (DES) were at 0.13, 5.03, and 0.02 μg L−1 in river water and 3.76, 13.25, and 0.10 μg L−1 in fish serum, respectively. Natural steroid hormones estrone (E1), 17β-estradiol (E2), and testosterone (T) were at 0.19, 0.11, and 6.22 μg L−1 in river water; and in female fish serum E1, E2, and pregnenolone (PREG) were at 1.37, 1.95, and 6.25 μg L−1, respectively. These results were confirmed by the manual method. The developed fully automated SPME and on-fiber silylation procedures showed satisfactory applications in environmental analysis and the performances show improved precision and a reduced analysis time compared to the manual method.  相似文献   

8.
The highly complex matrix of activated sludge in sewage treatment plants (STPs) makes it difficult to detect endocrine-disrupting chemicals (EDCs) which are usually present at low concentration levels. To date, no literature has reported the concentrations of steroid estrogens in activated sludge in China and very limited data are available worldwide. In this work, a highly selective and sensitive analytical method was developed for simultaneous determination of two classes of EDCs, including estrone (E1), 17β-estradiol (E2), estriol (E3), 17α-ethynylestradiol (EE2), 4-nonylphenol (NP) and bisphenol A (BPA), in the liquid and solid phases of activated sludge. The procedures for sample preparation, extracts derivatization, and gas chromatography–mass spectrometry (GC–MS) quantification were all optimized to effectively determine target EDCs while minimizing matrix interference. The developed method showed good calibration linearity, recovery, precision, and a low limit of quantification (LOQ) for all selected EDCs in both liquid and solid phases of activated sludge. It was successfully applied to determine the concentrations of EDCs in activated sludge samples from two STPs located in Beijing and Shanghai of China, respectively.  相似文献   

9.
A new analytical method based on simultaneous derivatization and dispersive liquid–liquid microextraction (DLLME) followed by gas chromatography–mass spectrometry (GC–MS), for the determination of the allergenic compounds atranol and chloroatranol in perfumes, is presented. Derivatization of the target analytes by means of acetylation with anhydride acetic in carbonate buffer was carried out. Thereby volatility and detectability were increased for improved GC–MS sensitivity. In addition, extractability by DLLME was also enhanced due to a less polar character of the solutes. A liquid–liquid extraction was performed before DLLME to clean up the sample and to obtain an aqueous sample solution, free of the low polar matrix from the essential oils, as donor phase. Different parameters, such as the nature and volume of both the extraction and disperser solvents, the ionic strength of the aqueous donor phase or the effect of the derivatization reagent volume, were optimized. Under the selected conditions (injection of a mixture of 750 μL of acetone as disperser solvent, 100 μL of chloroform as extraction solvent and 100 μL of anhydride acetic as derivatization reagent) the figures of merit of the proposed method were evaluated. Limits of detection in the low ng mL−1 range were obtained. Matrix effect was observed in real perfume samples and thus, standard addition calibration is recommended.  相似文献   

10.
Adhesives are often responsible for off-flavors in food in contact with packaging. The aim of this investigation was to identify by GC–O–MS the odorous compounds in five different types of adhesive (hotmelt, vinyl acetate ethylene, starch, polyvinyl acetate and acrylic) used in food packaging. In order to obtain a substantial number of compounds, they were extracted by two complementary extraction methods: HS-SPE and HS-SPME. Fifteen minutes extraction time using PDMS fiber for hotmelt adhesive and DVD/CAR/PDMS fiber for the other adhesives were the best conditions for defining a representative solvent-free adhesive extract using a rapid and simple D-GC–O technique. Thirty-three compounds were identified by GC–O–MS. These include butyric acid, acetic acid, methyl butyrate, 1-butanol and nonanal, which were present in most of the adhesives under study producing cheesy, rancid, sour, medicinal and green aromas, respectively. The concentrations were determined, the most abundant compound being acetic acid with concentrations from 22.9 to 8930 μg g−1 of adhesive.  相似文献   

11.
A headspace solid-phase microextraction (HS-SPME) method in combination with gas chromatography–mass spectrometry (GC–MS) has been used for extraction and identification of components of the volatile fraction of Provola dei Nebrodi, a typical semi-hard Sicilian cheese. Cheese samples from different producers and at different ripening stages have been examined. The effects of various conditions (e.g. sample volume, sample headspace volume, sample heating temperature, extraction time, etc.) on extraction efficiency were studied in order to optimise the technique. The technique used made it possible to identify 61 components: fatty acids from C2 to C14 and their esters, aldehydes, alcohols, methyl ketones, -lactones, aromatic compounds, hydrocarbons and terpenes. The main components were butanoic, hexanoic and octanoic acids. The linear free fatty acids (FFA) from C2 to C10 were quantified by using the standard addition method. Calibration curves constructed for the FFA spiked into cheese were highly linear with a correlation coefficient R2>0.998. Significant statistical differences (P0.05) were evident for the even-carbon-number fatty acids during ripening.  相似文献   

12.
A method for the determination of 19 chlorophenols in industrial effluents samples using solid-phase microextraction (SPME) coupled to gas chromatography–mass spectrometry has been developed. Four kinds of different SPME fibres have been studied. Among them, the polyacrylate and carbowax®-divinylbenzene fibres were the most adequate. The extraction process was optimized by means of the experimental design, which allows the study of a large number of factors with a reasonable number of experiments. The optimized method allows the determination of the studied chlorophenols in complex matrices with a high organic content with detection limits down to 0.07?ng?mL?1 and RSD ranging from 4.4% to 13.8%. The recovery studies with spiked real effluent samples at low levels of chlorophenols ranged from 59.8% to 142.1% for the lowest level (0.5?ng?mL?1) and from 79.6% to 115.8% for the highest spiked level (2?ng?mL?1). These results show the suitability of the proposed method to monitor chlorophenols in complex samples. 2,4,5-TCP was detected at concentrations close to its limits of detection in effluents coming from an oil refinery.  相似文献   

13.
The objective of this paper is to investigate the potential of multiple headspace-solid-phase microextraction (MHS-SPME) for the determination of volatile compounds in complex matrix samples. A method based on MHS-SPME for the determination of around 20 volatile compounds, responsible of tomato flavour and aroma has been developed and validated, using gas chromatography with mass spectrometry (ion trap analyser) for analysis. For this purpose, the experimental β parameter, resulting from the MHS-SPME theoretical development, has been obtained from real sample analysis (in triplicate) for each identified compound, carrying out up to 5 consecutive extractions. Later, this parameter is used to perform quantitation of real samples after just a single HS-SPME extraction. Precision, expressed as repeatability, has been evaluated by analysing six replicates of a real sample, showing relative standard deviations between 4 and 20%. For accuracy study, quantitative results have been compared with those obtained by means of standard additions on replicate samples, and no statistically significant differences between the two methods were observed. Since MHS-SPME uses the estimated total area corresponding to the complete extraction of compounds (obtained from the β parameter), quantitation can be carried out by external calibration using standards in solvent and splitless injection, instead of by SPME. Linearity, tested in the range 0.05–15 μg/mL, showed satisfactory values, with coefficients of correlation between 0.995 and 0.999. Limits of detection were in the range of 0.25–5 ng/g. MHS-SPME has been proved to be an adequate technique to avoid matrix effects in complex samples quantitation. Its applicability to the determination of volatile tomato components, together with its limitations, is discussed in this article.  相似文献   

14.
This paper presents a fully automated method for determining ten primary amines in wastewater at ng/L levels. The method is based on simultaneous derivatization with pentafluorobenzaldehyde (PFBAY) and headspace solid-phase microextraction (HS-SPME) followed by gas chromatography coupled to ion trap tandem mass spectrometry (GC–IT-MS–MS). The influence of main factors on the efficiency of derivatization and of HS-SPME is described in detail and optimized by a central composite design. For all species, the highest enrichment factors were achieved using a 85 μm polyacrylate (PA) fiber exposed in the headspace of stirred water samples (750 rpm) at pH 12, containing 360 g/L of NaCl, at 40 °C for 15 min. Under optimized conditions, the proposed method achieved detection limits ranging from 10 to 100 ng/L (except for cyclohexylamine). The optimized method was then used to determine the presence of primary amines in various types of wastewater samples, such as influent and effluent wastewater from municipal and industrial wastewater treatment plants (WWTPs) and a potable water treatment plant. Although the analysis of these samples revealed the presence of up to 1500 μg/L of certain primary amines in influent industrial wastewater, the concentration of these compounds in the effluent and in municipal and potable water was substantially lower, at low μg/L levels. The new derivatization–HS-SPME–GC–IT-MS–MS method is suitable for the fast, reliable and inexpensive determination of primary amines in wastewater in an automated procedure.  相似文献   

15.
Monoacylglycerols (MAGs) are lipids found in trace amounts in plants and animal tissues. While they are widely used in various industrial applications, accurate determination of the regio-specific distribution is hindered by the lack of stable, commercially available standards. Indeed, unsaturated β-MAG (or Sn-2 MAG) readily undergoes isomerization into α-MAG (acyl chain is attached to the Sn-1 or the Sn-3 position). In the present study, we describe structural elucidation of α- and β-regio-isomers of monopalmitoyl-glycerol (MAG C16:0) as model compounds in their silylated forms using gas chromatography–mass spectrometry (GC–MS) with electronic impact (EI) ionization. MS fragmentation of α-MAG C16:0 is characterized by the loss of methylene(trimethylsilyl)oxonium (103 amu) and the consecutive loss of acyl chain yielding a fragment ion at m/z 205. The fragmentation pattern of β-MAG C16:0 shows a series of diagnostic fragments at m/z 218, 203, 191 and 103 that are not formed from the α-isomer and hereby enable reliable distinction of these regio-isomers. Possible fragmentation scenarios are postulated to explain the formation of these marker ions, which were also applied to characterize the regio-isomer composition of a complex mixture of MAG sample containing n-3 long-chain polyunsaturated fatty acids.  相似文献   

16.
A simple and fast sample preparation method for the determination of nonylphenol (NP) and octylphenol (OP) in aqueous samples by simultaneous derivatization and dispersive liquid–liquid microextraction (DLLME) was investigated using gas chromatography–mass spectrometry (GC/MS). In this method, a combined dispersant/derivatization catalyst (methanol/pyridine mixture) was firstly added to an aqueous sample, following which a derivatization reagent/extraction solvent (methyl chloroformate/chloroform) was rapidly injected to combine in situ derivatization and extraction in a single step. After centrifuging, the sedimented phase containing the analytes was injected into the GC port by autosampler for analysis. Several parameters, such as extraction solvent, dispersant solvent, amount of derivatization reagent, derivatization and extraction time, pH, and ionic strength were optimized to obtain higher sensitivity for the detection of NP and OP. Under the optimized conditions, good linearity was observed in the range of 0.1–1000 μg L−1 and 0.01–100 μg L−1 with the limits of detection (LOD) of 0.03 μg L−1 and 0.002 μg L−1 for NP and OP, respectively. Water samples collected from the Pearl River were analyzed with the proposed method, the concentrations of NP and OP were found to be 2.40 ± 0.16 μg L−1 and 0.037 ± 0.001 μg L−1, respectively. The relative recoveries of the water samples spiked with different concentrations of NP and OP were in the range of 88.3–106.7%. Compared with SPME and SPE, the proposed method can be successfully applied to the rapid and convenient determination of NP and OP in aqueous samples.  相似文献   

17.
A sample pretreatment method for the determination of 18 chlorophenols (CPs) in aqueous samples by derivatization liquid-phase microextraction (LPME) was investigated using gas chromatography–mass spectrometry. Derivatization reagent was spiked into the extraction solvent to combine derivatization and extraction into one step. High sensitivity of 18 CPs derivatives could be achieved after optimization of several parameters such as extraction solvent, percentage of derivatization reagent, extraction time, pH, and ionic strength. The results from the optimal method showed that calibration ranging from 0.5 to 500 μg L−1 could be achieved with the RSDs between 1.75% and 9.39%, and the limits of detection (LOD) are ranging from 0.01 to 0.12 μg L−1 for the CPs. Moreover, the proposed LPME method was compared with solid-phase microextraction (SPME) coupled with on-fiber derivatization technique. The results suggested that using both methods are quite agreeable. Furthermore, the recoveries of LPME evaluated by spiked environmental samples ranged from 87.9% (3,5-DCP) to 114.7% (2,3,5,6-TeCP), and environmental water samples collected from the Pearl River were analyzed with the optimized LPME method, the concentrations of 18 CPs ranged from 0.0237 μg L−1 (3,5-DCP) to 0.3623 μg L−1 (2,3,6-TCP).  相似文献   

18.
Megastigmatrienone is a key flavor compound in tobacco. It has also been detected in wine, where it may contribute to a tobacco/incense aroma, but its importance and concentration in wines had never previously been evaluated.  相似文献   

19.
A new and simple APPI interface employing commercially available hardware is used to combine GC to MS. The feasibility of the method is demonstrated in the analysis of urine samples for neurosteroids as their trimethylsilyl (TMS) derivatives. The effect of different dopants (chlorobenzene, toluene, anisole) on the ionization of the TMS derivatives was investigated. With chlorobenzene, the TMS derivatives produced intense molecular ions with minimal fragmentation, and chlorobenzene was selected as best dopant. Protonated molecules in addition to intense molecular ions were produced with toluene and anisole. The performance of the method was verified in the analysis of human urine samples. Chromatographic performance was good with peak half-widths of 3.6–4.3 s, linearity (r2 > 0.990) was acceptable, limits of detection (LODs) were in the range of 0.01–10 ng mL−1, and repeatability was good with relative standard deviations (rsd%) below 22%. The results show that the method is well suited for the determination of neurosteroids in biological samples.  相似文献   

20.
A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p′-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号