首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 593 毫秒
1.
In this study, a procedure was developed to determine short-chain alkane monocarboxylic acids (SCMAs) in aqueous samples using headspace solid-phase microextraction (HS-SPME) followed by gas chromatography (GC) coupled with mass spectrometry (MS). A Stabilwax-DA capillary column (30 m × 0.32-mm inner diameter, 0.50-μm film thickness) was used for GC separation and a 60-μm poly(ethylene glycol) fiber was used to isolate SCMAs from water and introduce them into the gas chromatograph. Parameters of HS-SPME, analyte desorption, and GC-MS analysis were selected and an analytical procedure was proposed. Limits of quantitation were on the order of about 0.2 mg L-1. As an example of the application of the procedure, SCAMs were determined in municipal wastewater at different steps of treatment.  相似文献   

2.
Microchannel devices were constructed from low-temperature co-fired ceramic (LTCC) materials with screen-printed gold (SPG) electrodes in three dimensions—on all four walls—for self-contained enzyme-linked immunosorbant assays with electrochemical detection. The microchannel confines the solution to a small volume, allowing concentration of electroactive enzymatically generated product and nearby electrodes provide high-speed and high-sensitivity detection: it also facilitates future integration with microfluidics. LTCC materials allow easy construction of three-dimensional structures compared with more traditional materials such as glass and polymer materials. Parallel processing of LTCC layers is more amenable to mass production and fast prototyping, compared with sequential processing for integrating multiple features into a single device. LTCC and SPG have not been reported previously as the basis for microchannel immunoassays, nor with integrated, individually addressable electrodes in three dimensions. A demonstration assay for mouse IgG at 5.0 ng/mL (3.3 × 10-11 M) with electrochemical detection was achieved within a 1.8 cm long × 290 μm high × 130 μm wide microchannel (approximately 680 nL). Two of four SPG electrodes span the top and bottom walls and serve as the auxiliary electrode and the assay site, respectively. The other two (0.7 cm long × 97 μm wide) are centered lengthwise on the sidewalls of the channel. One serves as the working and the other as the pseudoreference electrode. The immunoassay components were immobilized at the bottom SPG region. Enzymatically generated p-aminophenol was detected at the internal working electrode within 15 s of introducing the enzyme substrate p-aminophenyl phosphate. A series of buffer rinses avoided nonspecific adsorption and false-positive signals.  相似文献   

3.
Cell microarrays with culture sites composed of individually removable microstructures or micropallets have proven benefits for isolation of cells from a mixed population. The laser energy required to selectively remove these micropallets with attached cells from the array depends on the microstructure surface area in contact with the substrate. Laser energies sufficient to release micropallets greater than 100 μm resulted in loss of cell viability. A new three-dimensional culture site similar in appearance to a table was designed and fabricated using a simple process that relied on a differential sensitivity of two photoresists to UV-mediated photopolymerization. With this design, the larger culture area rests on four small supports to minimize the surface area in contact with the substrate. Microtables up to 250 × 250 μm were consistently released with single 10-μJ pulses to each of the four support structures. In contrast, microstructures with a 150 × 150-μm surface area in contact with the substrate could not be reliably released at pulse energies up to 212 μJ. Cassie–Baxter wetting is required to provide a barrier of air to localize and sequester cells to the culture sites. A second asset of the design was an increased retention of this air barrier under conditions of decreased surface tension and after prolonged culture of cells. The improved air retention was due to the hydrophobic cavity created beneath the table and above the substrate which entrapped air when an aqueous solution was added to the array. The microtables proved an efficient method for isolating colonies from the array with 100% of selected colonies competent to expand following release from the array.  相似文献   

4.
A new type of capacitance-coupled contactless conductivity detection (C4D) system with sidewall electrodes was proposed for integration on a silicon-on-isolator–poly(dimethylsiloxane) (SOI-PDMS) hybrid low-voltage-driven electrophoresis microchip. By a microelectromechanical system process, the sidewall electrodes were fabricated precisely at either side of the separation channel. The area of the capacitor electrodes was the maximum value to improve the detection sensitivity with an enhanced capacitance effect. According to the simulation results, the structural parameters of the sidewall electrodes were determined as 550-μm length, 15-μm width, 80-μm separation distance, and 1-μm isolator thickness. The integrated microdevice with the SOI-PDMS hybrid electrophoresis microchip was very compact and the size was only 15 cm × 15 cm × 10 cm (width × length × height), which permitted miniaturization and portability. The detector performance was evaluated by K+ testing. The detection limit of the conductivity detector was determined to be 10-9 and 10-6 M for K+ in the static and electric-driven modes, respectively. Finally, the C4D was applied to low-voltage-driven electrophoresis on a microchip to carry out real-time measurement of the separation of amino acids. The separations of 10-4 M lysine and phenylalanine in the low-voltage-driven electrophoresis mode were performed with an electric field of 300 V/cm and were completed in less than 15 min with a resolution of 1.3. The separation efficiency was found to be 1.3 × 103 and 2.8 × 103 plates for lysine and phenylalanine, respectively, with a migration time reproducibility of 2.7 and 3.2%. The conductivity detection limit of amino acids achieved was 10-6 M. The proposed method for the construction of a novel C4D integrated on an SOI-PDMS hybrid low-voltage-driven electrophoresis microchip showed the most extensive integration and miniaturization of a microdevice, which is a further crucial step toward the realization of the “lab-on-a-chip” concept.  相似文献   

5.
The development of a simple and rapid high-performance liquid chromatography (HPLC) method for the determination of the new antiepileptic drug rufinamide (RFN) in human plasma and saliva is reported. Samples (250 μl) are alkalinized with ammonium hydroxide (pH 9.25) and extracted with dichloromethane using metoclopramide as internal standard. Separation is achieved with a Spherisorb silica column (250 × 4.6 mm i.d., 5 μm) at 30 °C using as mobile phase a solution of methanol/dichloromethane/n-hexane 10/25/65 (vol/vol/vol) mixed with 6 ml ammonium hydroxide. The instrument used was a Shimadzu LC-10Av chromatograph and flow rate was 1.5 ml min-1, with a LaChrom L-7400 UV detector set at 230 nm. Calibration curves are linear [r 2 = 0.998 ± 0.002 for plasma (n = 10) and r 2 = 0.999 ± 0.001 for saliva (n = 9)] over the range of 0.25–20.0 μg ml-1, with a limit of quantification at 0.25 μg ml-1. Precision and accuracy are within current acceptability standards. The assay is suitable for pharmacokinetic studies in humans and for therapeutic drug monitoring.  相似文献   

6.
A poly(methyl methacrylate) microfluidic chip was used to perform a two-dimensional (2-D) separation of a complex protein mixture in short development times. The separation was performed by combining sodium dodecyl sulfate micro-capillary gel electrophoresis (SDS μ-CGE) with microemulsion electrokinetic chromatography (μ-MEEKC), which were used for the first and second dimensions, respectively. Fluorescently labeled Escherichia coli cytosolic proteins were profiled by this 2-D approach with the results compared to a similar 2-D separation using SDS μ-CGE × μ-MEKC (micelle electrokinetic chromatography). The relatively short column lengths (effective length = 10 mm) for both dimensions were used to achieve separations requiring only 220 s of development time. High spot production rates (131 ± 11 spots min−1) and reasonable peak capacities (481 ± 18) were generated despite the fact that short columns were used. In addition, the use of μ-MEEKC in the second dimension was found to produce higher peak capacities compared to μ-MEKC (481 ± 18 for μ-MEEKC and 332 ± 17 for μ-MEKC) due to the higher plate numbers associated with μ-MEEKC.  相似文献   

7.
We have evaluated the electrical characteristics of silicon-nodule-related via failures in the aluminum interconnects of silicon integrated circuits. Current-voltage measurements indicated that the conduction mechanism follows Ohm's law. The resistance was 1.5–3 kΩ for a silicon nodule at a via of 1.0 μm × 1.0 μm. When the applied voltage was 3–6 V, the resistance decreased abruptly. This transition (abrupt decrease in resistance) was irreversible. We think that the resistance of 1.5–3 kΩ and the transition voltage of 3–6 V are two factors characterizing the silicon nodule. We can explain these values by assuming that aluminum in the silicon nodules at a solubility limit concentration acts as an acceptor. Received: 22 February 1999 / Accepted: 30 June 1999  相似文献   

8.
Fast capillary electrophoresis–mass spectrometry measurements under counter-electroosmotic analyte migration conditions are presented. Efficient separations of a homologous series of six hyaluronan oligosaccharides (comprising 1–6 hyalobiuronic acid moieties) could be completed in 65 s. Separations were achieved in short-length fused silica capillaries under high electric field strengths of up to 1.25 kV·cm−1. Capillary inner diameters ranging from 5 to 50 μm were investigated, resulting in an optimal value of 15 μm. The influence of capillary dimensions and buffer composition on separation efficiency and sensitivity are discussed. Optimal separations were achieved using a 28 cm × 15 μm capillary, a separation high voltage of 35 kV, a background electrolyte of 25 mM ammonium acetate adjusted to pH 8.5, and negative ionization mode. The optimized method was successfully applied to a bovine testicular hyaluronidase digest of hyaluronan. Only minimal sample pretreatment for protein-containing samples is required. The simple manual injection procedure and fast separations allow for a sample throughput of 35 samples per hour.  相似文献   

9.
Dextromethorphan was extracted from human plasma samples (100 μL) using MonoTip C18 tips, which are packed with C18-bonded monolithic silica gel that is attached to the inside of the tip. The samples, which contained dextromethorphan and trimeprazine as an internal standard (IS), were mixed with 200 μL of distilled water and 50 μL of 1 mol/L glycine–sodium hydroxide buffer (pH 10). The mixture was extracted to the C18 phase of the tip by 20 sequential aspirating/dispensing cycles using a manual micropipettor. The analytes retained on the C18 phase were then eluted with methanol by five sequential aspirating/dispensing cycles. The eluate was injected directly into a gas chromatograph and detected by a mass spectrometer with selected ion monitoring in positive electron ionization mode. An Equity-5 fused silica capillary column (30 m × 0.32 mm i.d., film thickness 0.5 μm) gave adequate separation of the dextromethorphan, IS, and impurities. The recoveries of dextromethorphan and the IS spiked into plasma were >87.4%. The regression equation for dextromethorphan showed excellent linearity from 2.5 to 320 ng/mL of plasma, and the limit of detection was 1.25 ng/mL of plasma. The intraday and interday coefficients of variation were less than 10.5% and 14.7%, respectively. The accuracy ranged from 91.9% to 107%. The validated method was successfully used to quantify the plasma concentration of dextromethorphan in a human subject after oral administration of the drug.  相似文献   

10.
A new adsorbent is proposed for the solid-phase extraction of phenol and 1-naphthol from polluted water. The adsorbent (TX-SiO2) is an organosilica composite made from a bifunctional immobilized layer comprising a major fraction (91%) of hydrophilic diol groups and minor fraction (9%) of the amphiphilic long-chain nonionic surfactant Triton X-100 (polyoxyethylated isooctylphenol) (TX). Under static conditions phenol was quantitatively extracted onto TX-SiO2 in the form of a 4-nitrophenylazophenolate ion associate with cetyltrimethylammonium bromide. The capacity of TX-SiO2 for phenol is 2.4 mg g−1 with distribution coefficients up to 3.4 × 104 mL g−1; corresponding data for 1-naphthol are 1.5 mg g−1 and 3 × 103 mL g−1. The distribution coefficient does not change significantly for solution volumes of 0.025–0.5 L and adsorbent mass less than 0.03 g; 1–90 μg analyte can be easily eluted by 1–3 mL acetonitrile with an overall recovery of 98.2% and 78.3% for phenol and 1-naphthol, respectively. Linear correlation between acetonitrile solution absorbance (A 540) and phenol concentration (C) in water was found according to the equation A 540 = (6 ± 1) × 10−2 + (0.9 ± 0.1)C (μmol L−1) with a detection range from 1 × 10−8 mol L−1 (0.9 μL g−1) to 2 × 10−7 mol L−1 (19 μL g−1), a limit of quantification of 1 μL g−1 (preconcentration factor 125), correlation coefficient of 0.936, and relative standard deviation of 2.5%. A solid-phase colorimetric method was developed for quantitative determination of 1-naphthol on adsorbent phase using scanner technology and RGB numerical analysis. The detection limit of 1-naphthol with this method is 6 μL g−1 while the quantification limit is 20 μL g−1. A test system was developed for naked eye monitoring of 1-naphthol impurities in water. The proposed test kit allows one to observe changes in the adsorbent color when 1-naphthol concentration in water is 0.08–3.2 mL g−1.  相似文献   

11.
The glass bead is a new biochip support material for immobilization biomolecules, due to its independence and convenient rearrangement. In order to optimize the immobilization efficiency of oligonucleotides onto glass beads and obtain the highest hybridization efficiency, three commonly used coupling strategies have been studied for covalently attaching oligonucleotides onto large glass beads. Glass beads with 250 μm diameter were amino-silaned with 2% 3-aminopropyltrimethoxysilane (APTMS) and then reacted separately with glutaraldehyde, succinic anhydride and 1,4-phenylene diisothiocyanate (PDITC) to derive CHO beads, COOH beads and isothiocyanate-modified beads (NCS-Beads) accordingly. Afterwards, amino-terminal oligonucleotides were covalently attached onto the surface of beads achieved by three strategies mentioned above. The immobilization efficiency were studied to compare the three strategies, which turned out 2.55 × 1013 probes/cm2 for CHO-Beads, 3.21 × 1013 probes/cm2 for COOH beads and 6.68 × 1013 probes/cm2 for NCS beads. It meant that the immobilization efficiency based on NCS beads was most acceptable. And the method, developed by attaching amino-terminal oligonucleotides onto these cyanate active beads, could be regarded as an efficient one for immobilizing oligonucleotides onto a solid surface. Moreover, in this paper, the hybridization properties of NCS bead-based oligonucleotides have been studied by employing Cy5-tagged complementary oligonucleotides. It was found that the high probe density NCS beads led to low hybridization efficiency possibly due to the existence of steric crowding. In addition, the equilibrium binding constant K A was determined by employing Langmuir isotherm model, which was 7.0 × 106 M−1 for NCS beads with the density of 6.7 × 1013 probes/cm2. Furthermore, it only took 60 min to reach hybridization equilibrium. These large microspheres (>100 μm) can be employed in the mesofluidic systems for automated heterogeneous assays.  相似文献   

12.
Both nitrazepam and flunitrazepam have been determined by high-performance liquid chromatography dual electrode detection (LC-DED) in the reductive–reductive mode, using a carbon fibre veil electrode (CFVE) in conjugation with a glassy carbon electrode. Initial studies were made to optimise the chromatographic conditions. These were found to be 45% acetonitrile-55% acetate buffer (50 mM, pH 4.1) at a flow rate of 1.0 ml/min, employing a Hypersil C18, 5 μm, 250 mm × 4.6 mm column. Cyclic voltammetric studies performed to ascertain the redox behaviour of nitrazepam and flunitrazepam at a CFVE in the optimised mobile phase. Studies showed that similar voltammetric behaviour was obtained to that report at Hg or glassy carbon based electrodes. Further studies were then carried out to identify the optimum conditions required for the LC-DED determination of nitrazepam and flunitrazepam in beverage samples. Hydrodynamic voltammetry was used to optimise the applied potential at the generator and detector cells; these were identified to be −2.40 and −0.25 V, respectively. A linear range of 2.0 to 100 μg ml−1, with a detection limit of 20 ng ml−1 was obtained. A convenient and rapid method for the determination of both nitrazepam and flunitrazepam in beverage sample was developed. Following a simple sample extraction procedure, extracts were examined using the optimised LC-DED procedure. An average percentage recovery of 95.5% (%CV = 4.5%) for nitrazepam and 78.0% (%CV = 8.8%) was achieved for a sample of “Pepsi Max” spiked at 1.0 μg ml−1 nitrazepam, 1.47 μg ml−1 flunitrazepam. Presented at the 4th Annual Meeting of the Great Western Electrochemistry Group, 8th June 2005, University of the West of England, Bristol, UK.  相似文献   

13.
The electrochemical behavior of sodium alendronate on copper microparticle- and copper nanoparticle-modified carbon paste electrodes was investigated. In the voltammograms recorded using microparticles, a single anodic oxidation peak appeared, while using nanoparticles, two anodic peaks appeared. The anodic currents were related to the electrocatalytic oxidation of alendronate via the active species of Cu(III). The catalytic rate constant for the electrocatalytic oxidation process and the diffusion coefficient of alendronate were obtained to be 1.57 × 103 cm3 mol−1 s−1 and 2.44 × 10−6 cm2 s−1, respectively. A sensitive and time-saving detection procedure was developed for the analysis of alendronate, and the corresponding analytical parameters were reported. Alendronate was determined with a limit of detection of 11.26 μmol L−1 with a linear range of 50–6,330 μmol L−1. The proposed amperometric method was applied to the analysis of commercial pharmaceutical tablets, and the results were in good agreement with the declared values.  相似文献   

14.
SiO2/ZrO2/C carbon ceramic material with composition (in wt%) SiO2 = 50, ZrO2 = 20, and C = 30 was prepared by the sol–gel-processing method. A high-resolution transmission electron microscopy image showed that ZrO2 and the graphite particles are well dispersed inside the matrix. The electrical conductivity obtained for the pressed disks of the material was 18 S cm−1, indicating that C particles are also well interconnected inside the solid. An electrode modified with flavin adenine dinucleotide (FAD) prepared by immersing the solid SiO2/ZrO2/C, molded as a pressed disk, inside a FAD solution (1.0 × 10−3 mol L−1) was used to investigate the electrocatalytic reduction of bromate and iodate. The reduction of both ions occurred at a peak potential of −0.41 V vs. the saturated calomel reference electrode. The linear response range (lrr) and detection limit (dl) were: BrO3 , lrr = 4.98 × 10−5–1.23 × 10−3 mol L−1 and dl = 2.33 μmol L−1; IO3 , lrr = 4.98 × 10−5 up to 2.42 × 10−3 and dl = 1.46 μmol L−1 for iodate.  相似文献   

15.
In this paper, an electrochemical sensor for sensitive and convenient determination of salicylic acid (SA) was constructed using well-aligned multiwalled carbon nanotubes as electrode material. Compared to the glassy carbon electrode, the electro-oxidation of SA significantly enhanced at the multiwalled carbon nanotube (MWCNT) electrode. The MWCNT electrode shows a sensitivity of 59.25 μA mM−1, a low detection limit of 0.8 × 10−6 M and a good response linear range with SA concentration from 2.0 × 10−6 to 3.0 × 10−3 M. In addition, acetylsalicylic acid was determined indirectly after hydrolysis to SA and acetic acid, which simplified the detection process. The mechanism of electrochemical oxidation of SA at the MWCNT electrode is also discussed.  相似文献   

16.
A fast and sensitive liquid chromatography–mass spectrometry method was developed for the determination of ursolic acid (UA) in rat plasma and tissues. Glycyrrhetinic acid was used as the internal standard (IS). Chromatographic separation was performed on a 3.5 μm Zorbax SB-C18 column (30 mm × 2.1 mm) with a mobile phase consisting of methanol and aqueous 10 mM ammonium acetate using gradient elution. Quantification was performed by selected ion monitoring with (m/z) 455 for UA and (m/z) 469 for the IS. The method was validated in the concentration range of 2.5 − 1470 ng mL−1 for plasma samples and 20 − 11760 ng g−1 for tissue homogenates. The intra- and inter-day assay of precision in plasma and tissues ranged from 1.6% to 7.1% and 3.7% to 9.0%, respectively, and the intra- and inter-day assay accuracy was 84.2 − 106.9% and 82.1 − 108.1%, respectively. Recoveries in plasma and tissues ranged from 83.2% to 106.2%. The limits of detections were 0.5 ng mL−1 or 4.0 ng g−1. The recoveries for all samples were >90%, except for liver, which indicated that ursolic acid may metabolize in liver. The main pharmacokinetic parameters obtained were T max = 0.42 ± 0.11 h, C max = 1.10 ± 0.31 μg mL−1, AUC = 1.45 ± 0.21 μg h mL−1 and K a = 5.64 ± 1.89 h−1. The concentrations of UA in rat lung, spleen, liver, heart, and cerebellum were studied for the first time. This method is validated and could be applicable to the investigation of the pharmacokinetics and tissue distribution of UA in rats.  相似文献   

17.
In the present work, a fluorimetric automatic method based on multisyringe flow injection analysis (MSFIA) was developed for in vitro evaluation of scavenging capacity against nitric oxide (NO) using 4,5-diaminofluorescein (DAF-2) as an NO-selective fluorogenic probe. The MSFIA manifold was assembled to perform the in-line generation of NO and the competitive reaction of putative scavenger molecules and DAF-2 with NO at conditions close to those found in vivo regarding temperature (37°C), pH (7.4), and concentration of NO (less than 1 μM). This approach allowed the evaluation of scavenging capacity against NO by endogenous antioxidant molecules, pharmaceutical compounds, and human plasma. IC50 values were calculated for rutin (1.30 ± 0.02 μM, positive control), cysteine (321 ± 8 μM), reduced glutathione (1106 ± 93 μM), uric acid (134 ± 12 μM), dipyrone (1.36 ± 0.06 μM), and captopril (363 ± 28 μM). A high degree of automation was attained as the successive dilution of antioxidant standard solutions required for IC50 assessment was performed automatically, in a dilution chamber placed in the flow system. A determination throughput of 16 h-1 and a good precision were attained (relative standard deviation between 1.6 and 9.0%), fostering the application of the proposed method to routine/screening analysis of scavenging capacity against NO.  相似文献   

18.
FTIR microscopy with a focal plane array (FPA) of detectors enables routine chemical imaging on individual cells in only a few minutes. The brilliance of synchrotron radiation (SR) IR sources may enhance the signal obtained from such small biosamples containing small amounts of organic matter. We investigated individual cells obtained from a cell culture specifically developed for transmission FTIR imaging using either a Globar or an SR source coupled to the same instrumentation. SR-IR source focussing was optimized to control the energy distribution on the FPA of detectors. Here we show that accessing the IR absorption distribution from all the organic contents of cells at 1 × 1 μm pixel resolution was possible only with high circulating current (≥1.2 A) illuminating a limited number of the FPA’s detectors to increase the signal-to-noise ratio of IR images. Finally, a high-current SR ring is mandatory for collecting FTIR images of biosamples with a high contrast in minutes.  相似文献   

19.
Letrozole is an efficient endocrine treatment of postmenopausal breast cancer, however, not all patients benefit from this treatment, and moreover, severe side-effects like arthralgia frequently lead to discontinuation. To better understand inter-individual variability in drug response and side-effects, plasma analysis of steady-state concentrations of letrozole and its major metabolites is crucial. We developed a rapid, sensitive, and specific method for the simultaneous quantification of letrozole and its metabolites 4,4′-(hydroxymethylene)dibenzonitrile (carbinol) and bis(4-cyanophenyl)methyl hexopyranosiduronic acid (carbinol-gluc) by UHPLC-ESI-MS/MS using in-house synthesized, stable isotope-labeled internal standards. Following solid-phase extraction in BondElut C18 96-well plates, the analytes were separated on a ZORBAX Eclipse XDB-C18 column (1.8 μm, 4.6 × 50 mm) with a gradient of acetonitrile in 0.1% acetic acid in water and detected on a triple quadrupole mass spectrometer with electrospray ionization in the multiple reaction monitoring mode. Lower limits of quantification were 20, 0.2, and 2 nM for letrozole, carbinol, and carbinol-gluc, respectively. The assay has been validated according to FDA guidance and applied to the analysis of 20 plasma samples of postmenopausal breast cancer patients treated with 2.5 mg of letrozole per day. Mean plasma levels (±SD) were 366 ± 173, 0.38 ± 0.09, and 34 ± 12 nM for letrozole, carbinol, and carbinol-gluc, respectively. Our rapid and sensitive mass spectrometry based method enables future pharmacokinetic investigations of letrozole outcome.  相似文献   

20.
A high-performance liquid chromatographic (HPLC) method with fluorescence detection for the quantification of vancomycin in human plasma was developed and validated. The method includes an extraction of vancomycin by deproteinization with acetonitrile. The analyses were carried out at 258 nm as the emission wavelength while exciting at 225 nm on a reversed-phase column (30 cm × 4 mm i.d. × 10 μm Waters Associates μBondapak C18) using a mobile phase composed of methanol and phosphate buffer at pH 6.3. Vancomycin was quantitatively recovered from human plasma samples (>96%) with high values of precision. The separation was completed within 27 min. The calibration curve was linear over the range from 5 to 1,000 ng/mL with the detection and quantification limits of 2 ng/mL and 5 ng/mL, respectively. This method is suitable for the routine assay of plasma samples. Figure The effect of the deproteinization solvent on the signal of the interference peak at retention time of 15.0 min. The peak which interferes with the peaks of Erythromycin and Vancomycin has been disappeared by using 2 mL acetonitrile as the deproteinization solvent.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号