首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
An ultra-fast analysis of proteins, based on sodium dodecyl sulfate (SDS)-mediated gel electrophoresis was developed, in which protein molecular mass standards ranging from Mr 14 200 to 94 700 were separated within 3 min. A 50 μm diameter uncoated fused-silica capillary column and a high field strength are used. The effects of the SDS concentration in the separation gel buffer and in the sample buffer on the resolution of protein test mixture were studied. The influence of the heat treatment of the sample prior analysis is also discussed.  相似文献   

2.
Simpson DC  Smith RD 《Electrophoresis》2005,26(7-8):1291-1305
Mass spectrometry (MS)-based proteomics is currently dominated by the analysis of peptides originating either from digestion of proteins separated by two-dimensional gel electrophoresis (2-DE) or from global digestion; the simple peptide mixtures obtained from digestion of gel-separated proteins do not usually require further separation, while the complex peptide mixtures obtained by global digestion are most frequently separated by chromatographic techniques. Capillary electrophoresis (CE) provides alternatives to 2-DE for protein separation and alternatives to chromatography for peptide separation. This review attempts to elucidate how the most promising CE modes, capillary zone electrophoresis (CZE) and capillary isoelectric focusing (CIEF), might best be applied to MS-based proteomics. CE-MS interfacing, mass analyzer performance, column coating to minimize analyte adsorption, and sample stacking for CZE are considered prior to examining numerous applications. Finally, multidimensional systems that incorporate CE techniques are examined; CZE often finds use as a fast, final dimension before ionization for MS, while CIEF, being an equilibrium technique, is well-suited to being the first dimension in automated fractionation systems.  相似文献   

3.
Kim KH  Lee JY  Moon MH 《The Analyst》2011,136(2):388-392
Effects of protein denaturation and formation of protein-sodium dodecyl sulfate (SDS) complexes on protein separation and identification were investigated using hollow fiber flow field-flow fractionation (HF5) and nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry (nLC-ESI-MS-MS). Denaturation and formation of protein-SDS complexes prior to HF5 separation resulted an increase in the retention of few protein standards due to unfolding of the protein structures and complexation, yielding ~30% increase in hydrodynamic diameter. In addition, low molecular weight proteins which could be lost from the HF membrane due to the pore size limitation showed an increase of peak recovery about 2-6 folds for cytochrome C and carbonic anhydrase. In the case of proteins composed of a number of subunits, denaturation resulted in a decrease in retention due to dissociation of protein subunits. A serum proteome sample, denatured with dithiothreitol and SDS, was fractionated by HF5, and the eluting protein fractions after tryptic digestion were analyzed for protein identification using nLC-ESI-MS-MS. The resulting pools of identified proteins were found to depend on whether the serum sample was treated with or without denaturation prior to the HF5 run due to differences in the aqueous solubility of the proteins. The enhancement of protein solubility by SDS also increased the number of identified membrane proteins (54 vs. 31).  相似文献   

4.
Sim TS  Kim EM  Joo HS  Kim BG  Kim YK 《Lab on a chip》2006,6(8):1056-1061
We have carried out a simultaneous thermal denaturation and trypsin digestion of proteins using a temperature-controllable microreactor. This is a simple and rapid sample preparation technique for use before matrix-assisted laser desorption ionization time-of-flight mass spectrometry. In contrast to a conventional sample preparation method, which involves several chemical treatments, our sample preparation was performed using only trypsin digestion with the thermal denaturation of the target protein. Optimization of the reactor operational parameters for trypsin digestion using a temperature-controllable microreactor was carried out. The entire trypsin digestion procedure took about 11 min, and consisted of 1 min for the thermal denaturation of the sample protein (3 microl, 0.2 microM) at 85 degrees C, and 10 min for digestion of the protein at 37 degrees C. The resulting sequence coverage ranged from 24% to 57%, which was sufficient for practical protein identification.  相似文献   

5.
The coupling of the widely used separation technique of conventional sodium dodecylsulfate polyacrylamide gel electrophoresis (SDS-PAGE) with the mass accuracy measurement capability of mass Spectrometry (MS) provides a very powerful analytical technique. However, at present, there is no simple, definitive method for coupling the two methods. Typically, separated proteins are extracted from the gel, either as the native protein or as a peptide mixture after in-gel proteolytic digestion, and then analyzed by mass Spectrometry. However, the various extraction techniques described previously have been labor intensive and require a large number of steps. The mass Spectrometry analysis of very low concentrations of in vivo derived proteins requires minimum sample handling and on-line concentration. Therefore, we have developed an efficient microelectroelution technique that is applied in a single step manner and contains an on-line concentration device. Initial results from this system have shown a high efficiency of analyte elution from the gel and a simple, robust technique for the coupling of SDS-containing gels with MALDI-TOF-MS analysis and a capability of analyzing proteins at the subpicomole level.  相似文献   

6.
High-sensitivity, high-throughput analysis of proteins for proteomics studies is usually performed by polyacrylamide gel electrophoresis in combination with mass spectrometry. However, the quality of the data obtained depends on the in-gel digestion procedure employed. This work describes an improvement in the in-gel digestion efficiency for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) analysis. A dramatic improvement in the coverage of tryptic peptides was observed when n-octyl glucoside was added to the buffer. Whole cell extracted proteins from S. cerevisiae were separated by two-dimensional gel electrophoresis and stained with silver. Protein spots were identified using our improved in-gel digestion method and MALDI-TOFMS. In addition, the mass spectra obtained by using the matrix alpha-cyano-4-hydroxycinnamic acid (CHCA) were compared with those obtained using 2,5-dihydroxybenzoic acid (DHB). The DHB matrix usually gave more peaks, which led to higher sequence coverage and, consequently, to higher confidence in protein identification. This improved in-gel digestion protocol is simple and useful for protein identification by MALDI-TOFMS.  相似文献   

7.
Accelerated tryptic digestion of a therapeutic protein including microwave irradiation and thermal transfer by convection at 60 °C and 37 °C was investigated. An analytical setup was devised to follow the protein digestion rate using 1D gel electrophoresis and liquid chromatography coupled a triple quadrupole linear ion trap mass spectrometer. The formation kinetic of its tryptic peptides was monitored in the selected monitoring mode (LC-SRM/MS). Different digestion end points (e.g. 2, 5, 10, 15, 30 and 60 min) as well as an overnight digestion were tested using a therapeutic human monoclonal antibody (mAb) with the goal of its LC-SRM/MS quantification in human plasma. The peptides from the human mAb were generated at different rates and were classified into three categories: (1) the fast forming peptides, (2) the slow forming peptides and (3) the peptides degrading over time. For many monitored peptides, a heating temperature of 37 °C with a 750 rpm mixing applied for at least 30 min provided equivalent results to microwave-assisted digestion and generally allowed the achievement of an equivalent peptide concentration as an overnight digestion carried out at 37 °C. The disappearance of the protein of the heavy and light chains can be monitored by 1D gel electrophoresis but was found not to be representative of the final tryptic peptide concentrations. For quantitative purposes a stable isotope labeled version (13C4, 15N1) of the therapeutic protein was used. The labeled protein as internal standard was found to be very efficient to compensate for incomplete digestion or losses during sample preparation.  相似文献   

8.
To facilitate a direct interface between protein separation by PAGE and protein identification by mass spectrometry, we developed a multichannel system that continuously collects fractions as protein bands migrate off the bottom of gel electrophoresis columns. The device was constructed using several short linear gel columns, each of a different percent acrylamide, to achieve a separation power similar to that of a long gradient gel. A “Counter Free‐Flow” elution technique then allows continuous and simultaneous fraction collection from multiple channels at low cost. We demonstrate that rapid, high‐resolution separation of a complex protein mixture can be achieved on this system using SDS‐PAGE. In a 2.5 h electrophoresis run, for example, each sample was separated and eluted into 48–96 fractions over a mass range of ~10–150 kDa; sample recovery rates were 50% or higher; each channel was loaded with up to 0.3 mg of protein in 0.4 mL; and a purified band was eluted in two to three fractions (200 μL/fraction). Similar results were obtained when running native gel electrophoresis, but protein aggregation limited the loading capacity to about 50 μg per channel and reduced resolution.  相似文献   

9.
A tissue proteomics process is presented where hepatocyte cell isolation in combination with two-dimensional (2-D) gel electrophoresis and mass spectrometric identification were used to annotate the liver proteome. Laser microdissection of 8 microm liver tissue sections was performed and protein expression profiling was compared using a variety of quantities of input cells, and gel separation conditions. The 30 microm diameter laser generated the highest protein yields from the polymer coated caps following microsolubilization. We found that 6000 laser pulses (approximately 7200 hepatocytes) were required in order to generate high-resolution gel maps. Within homogeneous tissue samples, this could be accomplished in a total cycle time of 20 min using an automated dissection procedure. Close to 1000 high-quality gel annotations were generated from the corresponding 2-D gel expression profiles which matched closely the corresponding patterns of analytical-scale liver preparations detected by silver staining.  相似文献   

10.
Schmidt AC  Störr B  Kummer NA 《Talanta》2011,85(2):1118-1128
Three independent methods, (i) electrospray ionization mass spectrometry (ESI-MS), (ii) carrying out the complete protein preparation procedure required for protein gel electrophoresis (GE) including extraction, precipitation, washing, and desalting with subsequent microwave digestion of the produced protein fractions for metal content quantification, and (iii) ultrafiltration for separating protein-bound and unbound metal fractions, were employed to elucidate the influences of protein sample preparation and GE running conditions on metal-protein bindings. A treatment of the protein solution with acetone instead of trichloroacetic acid or ammonium sulfate for precipitate formation led to a strongly enhanced metal binding capacity. The desalting step of the resolubilized protein sample caused a metal loss between 10 and 35%. The omission of some extraction buffer additives led to a diminished metal binding capacity of protein fractions obtained from the sample preparation procedure for GE, whereas a tenside addition to the protein solution inhibited metal-protein bindings. The binding stoichiometry of Cu and Zn-protein complexes determined by ESI-MS was influenced by the type of the metal salt which was applied to the protein solution. A higher pH value of the sample solution promoted the metal ion complexation by the proteins. Ultrafiltration experiments revealed a higher Cu- and Zn-binding capacity of the model protein lysozyme in both resolubilization buffers for 1D- and 2D-GE compared to the protein extraction buffer. Strongly diminished metal binding capacities of lysozyme were recorded in the running buffer of 1D-GE and in the gel staining solutions.  相似文献   

11.
Preconcentration of chemical warfare agent degradation products (alkylphosphonic acids and alkyl alkylphosphonic acids) in low-conductivity matrices (purified water, tap water and local river water) by field-amplified sample stacking (FASS) was developed for capillary electrophoresis (CE) coupled to ion trap mass spectrometry. FASS was performed by adding a mixture of HCOONH(4) and NH(4)OH in appropriate concentrations to the sample. This allowed to control the conductivity and the pH of the sample in order to obtain FASS performances that are independent of analyte concentration. The influence of different parameters on FASS (sample to background electrolyte (BGE) conductivity ratio, injection volume and concentration of BGE) was studied to determine the optimal conditions and was rationalized by using the theoretical model developed by Burgi and Chien. A good correlation was obtained between the bulk electroosmotic velocity predicted by this model and the experimental value deduced from the migration time of the electroosmotic flow marker detected by mass spectrometry (MS). This newly developed method was successfully applied to the analysis of tap water and local river water fortified with the analytes and provided a 10-fold sensitivity enhancement in comparison to the signal obtained without preconcentration procedure. The quite satisfactory repeatability and linearity for peak areas obtained in the 0.5-5 microg mL(-1) concentration range allow quantitative analysis to be implemented. Limits of detection of 0.25-0.5 microg mL(-1) for the alkyl alkylphosphonic acids and of 0.35-5 microg mL(-1) for the alkylphosphonic acids were reached in tap water and river water.  相似文献   

12.
Two-dimensional gel electrophoresis practitioners have long waited for a fully automated system. This article presents an integrated platform that is capable of complete automation from sample introduction to spots detection. The strip gel for the first dimensional separation is fixed on the edge of a discrete planar stage before separation. A pair of platinum pin electrodes for isoelectric focusing (IEF) makes contact from underneath the stage. IEF is performed directly after rehydration and protein loading. After the first dimensional separation, sodium dodecyl sulfate (SDS) equilibration is done on the same stage without moving the gel. The IEF stage is then moved horizontally to couple with a precast second dimensional gel. The <0.5 mm gap between the two gels is filled with poly (ethylene oxide) solution. After SDS-polyacrylamide gel electrohporesis separation, a charge-coupled device camera is used to detect spots via protein native fluorescence excited by a Hg (Xe) lamp with the gel inside the running cell. Potential for full automation is demonstrated with 0.5 microg of Escherichia coli proteins on this miniaturized platform. More than 240 spots are detected in a total experiment time of <2.5 h.  相似文献   

13.
Claeys D  Geering K  Meyer BJ 《Electrophoresis》2005,26(6):1189-1199
Two-dimensional (2-D) Blue Native/SDS gel electrophoresis combines a first-dimensional separation of monomeric and multimeric proteins in their native state with a second denaturing dimension. These high-resolution 2-D gels aim at identifying multiprotein complexes with respect to their subunit composition. We applied this method for the first time to analyze two human platelet subproteomes: the cytosolic and the microsomal membrane protein fraction. Solubilization of platelet membrane proteins was achieved with the nondenaturing detergent n-dodecyl-beta-D-maltoside. To validate native solubilization conditions, we demonstrated the correct assembly of the Na,K-ATPase, a functional multimeric transmembrane protein, when expressed in Xenopus oocytes. We identified 63 platelet proteins after in-gel tryptic digestion of 58 selected protein spots and liquid chromatography-coupled tandem mass spectrometry. Nine proteins were detected for the first time in platelets by a proteomic approach. We also show that this technology efficiently resolves several known membrane and cytosolic multiprotein complexes. Blue Native/SDS gel electrophoresis is thus a valuable procedure to analyze specific platelet subproteomes, like the membrane(-bound) protein fraction, by mass spectrometry and immunoblotting and could be relevant for the study of protein-protein interactions generated following platelet activation.  相似文献   

14.
The role of separation science in proteomics research.   总被引:22,自引:0,他引:22  
H J Issaq 《Electrophoresis》2001,22(17):3629-3638
In the last few years there has been an increased effort into the separation, quantification and identification of all proteins in a cell or tissue. This is a review of the role gel electrophoresis, high performance liquid chromatography (HPLC), and capillary electrophoresis (CE) play in proteomics research. The capabilities and limitations of each separation technique have been pointed out. Instrumental strategies for the resolution of cell proteins which are based on efficient separation employing either a single high-resolution procedure or a multidimensional approach on-line or off-line, and a mass spectrometer for protein identification have been reviewed. A comparison of the advantages of multi-dimensional separations such as two-dimensional polyacrylamide gel electrophoresis, HPLC-HPLC, and HPLC-CE to the separation of cell and tissue proteins are discussed. Also, a discussion of novel approaches to protein concentration, separation, detection, and quantification is given.  相似文献   

15.
Two-dimensional gel electrophoresis, bioinformatics, and mass spectrometry are key analysis tools in proteome analysis. The further characterization of post-translational modifications in gel-separated proteins relies fully on data obtained by mass spectrometric analysis. In this study, stress-induced changes in protein expression in Saccharomyces serevisiae were investigated. A total of eleven spots on a silver-stained two-dimensional (2-D) gel were identified by matrix-assisted laser desorption/ionization (MALDI) peptide mass mapping to represent C and/or N-terminal processed forms of enolase 2. The processing sites were determined by MALDI peptide mass mapping using a variety of proteolytic enzymes, by optimizing the sample preparation procedure and by specific labeling of all C-termini derived from in-gel digestion using a buffer containing 16O:18O (1:1). Out of eleven processed forms of enolase 2, six were fully characterized and the approximate processing sites identified for the remaining five.  相似文献   

16.
R-phycoerythrin (PHYCO, Mr 240 000), glucose-6-phosphate dehydrogenase (GPD, Mr 104 000) and two charge isomers of recombinant green fluorescent protein (GFP-1 and GFP-2, Mr 27 000) were subjected to capillary zone electrophoresis (CZE) in capillaries of 50, 100 and 150 microm inner diameter at various sample concentrations, electric field strengths, and lengths of the initial zone with the purpose of testing the hypothesis that protein - capillary wall interactions rather than thermal effects are predominantly responsible for the peak spreading of proteins in CZE. The efficiency of CZE was expressed in terms of the number of theoretical plates, N, or the plate height corrected by subtracting the contribution from initial zone length, H'. The latter has the advantage of solely reflecting contributions to the separation efficiency arising from intracolumn peak spreading in capillaries of different diameters. The separation efficiency measured varied widely, by two orders of magnitude, for these proteins under identical conditions, with GPD exhibiting the highest and PHYCO the lowest values of N. H' was found to be independent of sample concentrations within the concentration ranges studied, 1-100 microg/mL for PHYCO and 100-1000 microg/mL for GPD, while exhibiting a decrease with sample concentration for GFP, especially in 150 microm diameter capillaries, within the concentration range 1-100 microg/mL. H'was also found to be independent of electric field strength up to 300-400 V/cm for PHYCO and GFP. In all experiments, the CZE of proteins in 100 microm diameter capillaries provided a higher or, at least, equal efficiency, compared to that in 50 or 150 microm diameter capillaries. It may be concluded that the protein - capillary wall interactions and protein microheterogeneity are the dominant sources of peak spreading and their specific combinations are thought to be responsible for the wide variation in separation efficiency between proteins in CZE observed under identical conditions.  相似文献   

17.
We describe an innovative approach - using a high concentration of trypsin-modified magnetic nanoparticles (TMNPs) - for the rapid and efficient digestion of proteins at elevated temperature. The required digestion time could be reduced to less than 10 s. After digestion, the TMNPs were collected magnetically from the sample solution for reuse and the digested peptides were characterized using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Protein digestion was optimized when using the TMNPs (5 microg/microL) at 57 degrees C; a significantly high peptide coverage was achieved for protein identification (e.g., 98% for lysozyme). Although a high concentration of TMNPs was used for digestion, the short digestion time led to much lower amounts of trypsin peptides being produced through self-digestion. As a result, interference in the mass spectrometric detection of the peptide ions was reduced significantly.  相似文献   

18.
A new clean fast (8 min) method for in-solution protein digestion without detergent or urea for protein identification by peptide mass fingerprint and mass spectrometry-based techniques is proposed. The new method avoids the use of time consuming desalting procedures entailing the following four steps done under the effect of an ultrasonic field provided by a sonoreactor: denaturation (1 min) in a mixed solution of water:acetonitrile 1/1 (v/v); protein reduction (1 min); protein alkylation (1 min); and protein digestion (5 min). Five proteins with masses comprised between 14.4 kDa and 97 kDa and the protein split-soret cytochrome c from D. desulfuricans ATCC27774, were successfully identified with this procedure. No differences were found in the sequence coverage or in the number of peptides matched when the new clean method was compared to another one using urea. Twofold better signal-to-noise ratios were obtained in the MALDI spectra from protein samples prepared with the new method when comparing it with a method using urea. The new digestion method avoids the need to remove salt content and increases throughput (six samples at once) while reducing sample loss and contamination from sample handling.  相似文献   

19.
Sequence-specific proteolysis is an important part of protein identification by MS. Digestion of protein is commonly performed in-solution, in sample vials with volumes ranging from milli- to microliters. When digestion is performed with a sample volume below 1 microL, handling of solution and potential sample loss via adsorption become significant issues. In this report, a proof of concept for the digestion of a small volume protein solution inside a capillary was demonstrated using a discontinuous buffer system previously studied (Nesbitt, C. A., et al. J. Chromatogr. A 2005, 1073, 175-180). Upon voltage application, a pH junction was created by the discontinuous buffer. Using myoglobin as an example, the protein molecules were enriched at the junction with an estimated volume of a few nanoliters. A protease, trypsin, was then introduced to myoglobin at the junction by coenrichment to induce in-capillary digestion. The voltage application was then suspended to provide the necessary time (2 h) for the proteolysis to proceed. When completed, voltage application was resumed, and the discontinuous buffer reconcentrated the peptides formed from digestion. Importantly, the refocused peptides appeared to roughly elute according to their pIs, resulting in a partial separation. Direct sample deposition from capillary was performed to facilitate mass spectral analysis by MALDI. The partial separation, according to pI, offered the potential benefits of MALDI MS signal enhancement and provided supplementary pI information for peptide identity assignment.  相似文献   

20.
The behavior of the multiheme protein hydroxylamine oxidoreductase (HAO) in polyacrylamide gel electrophoresis was studied at hydrostatic pressures up to 3 kbar at 25 degrees C. Due to the limited working volume of the high pressure vessel, the electrophoresis cells were miniaturized. A microcell which accommodates 6 capillary gel tubes is described. Between 1 bar and 1.5 kbar the enzyme did not undergo structural changes detectable in the gel system. At approximately 2 kbar the active form of the enzyme was partially dissociated. At higher pressures, the enzyme was converted to forms which were irreversibly inactive and had a higher apparent molecular mass, suggesting aggregation or denaturation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号