首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The effect of silver colloidal nanoparticles (AgNPs) on the luminol–isoniazid system was investigated. It was found that AgNPs could act as a nanocatalyst on the luminol–isoniazid system to generate chemiluminescence (CL). The CL emission spectrum of the luminol–isoniazid–AgNPs system showed a peak with a maximum at 425 nm. It was suggested that the luminophor species was the excited state 3-aminophthalate. The reduction of dissolved O2 to H2O2 by isoniazid and decomposition of H2O2 to the oxygen-related radicals were attributed to the catalytic effect of AgNPs. Under optimized conditions, the CL signal intensity was linear with the isoniazid concentration in the range of 10–1000 ng mL− 1, with the correlation coefficient of 0.9996. The limit of detection was 2.7 ng mL− 1 isoniazid. The relative standard deviations for seven repeated measurements of 60 and 200 ng mL− 1 isoniazid were 1.4 and 2.4%, respectively. The effect of potent interfering compounds on the CL signal intensity of the proposed luminol–isoniazid–AgNPs system was investigated. The proposed method was successfully applied to the determination of isoniazid in a pharmaceutical sample.  相似文献   

2.
A flow-injection chemiluminescence method for the determination of isoniazid based on the sensitizing effect of isoniazid on the chemiluminescence generating luminol-hypochlorite reaction is described. The hypochlorite was electrogenerated on-line by constant current electrolysis, thus, eliminating instability of hypochlorite solution prepared from commercially available sodium hypochlorite. The calibration graph is linear in the range 1 × 10–8 to 1 × 10–6 g mL–1, and the detection limit is 6 × 10–9 g mL–1. The relative standard deviation for determination of 5 × 10–8 g mL–1 is 2.8%. The proposed method has been successfully applied to the determination of isoniazid in pharmaceutical preparations.  相似文献   

3.
A flow-injection chemiluminescence method for the determination of isoniazid based on the sensitizing effect of isoniazid on the chemiluminescence generating luminol-hypochlorite reaction is described. The hypochlorite was electrogenerated on-line by constant current electrolysis, thus, eliminating instability of hypochlorite solution prepared from commercially available sodium hypochlorite. The calibration graph is linear in the range 1 × 10–8 to 1 × 10–6 g mL–1, and the detection limit is 6 × 10–9 g mL–1. The relative standard deviation for determination of 5 × 10–8 g mL–1 is 2.8%. The proposed method has been successfully applied to the determination of isoniazid in pharmaceutical preparations. Reveived: 2 May 1998 / Revised: 27 July 1998 / Accepted: 7 August 1998  相似文献   

4.
Li B  Zhang Z  Wu M 《Talanta》2000,51(3):515-521
A novel chemiluminescence (CL) flow system for the determination of quinine is described. It is based on the direct chemiluminescence reaction of quinine and cobalt(III) in sulfuric acid medium. The unstable Co(III) was on-line electrogenerated by constant-current electrolysis. The chemiluminescence intensity was linear with a quinine concentration in the range of 0.1-100 mug ml(-1). The determination limit was 3.3x10(-8) g ml(-1). The whole process could be completed in 1 min. The proposed method is suitable for automatic and continuous analysis, and has been applied successfully to the analysis of quinine in pharmaceutical preparation.  相似文献   

5.
A novel flow-injection chemiluminescence (CL) method for the determination of dihydralazine sulfate (DHZS) is described. The method is based on the reaction of luminol and diperiodatocuprate (K2[Cu(H2IO6)(OH)2], DPC) in alkaline medium to emit CL, which is greatly enhanced by DHZS. The possible CL mechanism was first proposed based on the kinetic characteristic, CL spectrum and UV spectra. The optimum condition for the CL reaction was in detail studied using flow-injection system. The experiments indicated that under optimum condition, the CL intensity was linearly related to the concentration of DHZS in the range of 7.0 × 10?9 to 8.6 × 10?7 g mL?1 with a detection limit (3σ) of 2.1 × 10?9 g mL?1. The proposed method had good reproducibility with the relative standard deviation 3.1% (n = 7) for 5.2 × 10?8 g mL?1 of DHZS. This method has the advantages of simple operation, fast response and high sensitivity. The special advantage of the system is that very low concentration of luminol can react with DPC catalyzed by DHZS to get excellent experiment results. And CL cannot be observed nearly when luminol with same concentration reacts with other oxidants, so luminol–DPC system has higher selectivity than other luminol CL systems. The method has been successfully applied to determine DHZS in serum.  相似文献   

6.
By designing a novel flow-through electrolytic cell (FEC), bromine was produced near to the surface of the platinum electrode by electrochemical oxidation of acidic KBr. The fast and weak chemiluminescence signal produced by the chemical reaction of the electrogenerated bromine with H2O2 was greatly enhanced by tetracyclines Based on these observations, a new, sensitive and simple electrogenerated chemiluminescence (ECL) method for the determination of tetracyclines was developed. Under the optimum experimental conditions, the calibration graphs are linear over the range 3.0×10−8 to 5.0×10−5 g ml−1 for tetracycline, 2.0×10−7 to 2.4×10−5 g ml−1 for oxytetracycline and 1.0×10−7 to 5.0×10−5 g ml−1 for chlortetracycline. The limits of detection (S/N=3) are 1.0×10−8 g ml−1 for tetracycline, 7.0×10−8 g ml−1 for oxytetracycline and 1.5×10−7 g ml−1 for chlortetracycline. For the determination 5.0×10−7 g ml−1 tetracycline, the relative standard deviation was <5%. The proposed method was used to determine tetracyclines in pharmaceutical formulations.  相似文献   

7.
在碱性介质中,去乙酰毛花苷对鲁米诺-KIO4发光体系有明显的抑制作用,且抑制效果与其质量浓度呈良好的线性关系,据此建立了去乙酰毛花苷的流动注射化学发光分析方法。该方法的线性范围为1.0×10-8~1.0×10-5g/mL,检出限为3.1×10-9g/mL,对1.0×10-7g/mL的去乙酰毛花苷进行连续11次平行测定,相对标准偏差为2.3%。可用于相应注射剂分析,并与药典方法进行对照。  相似文献   

8.
In this paper, molecularly imprinted polymer (MIP) of isoniazid is synthesized through thermal radical copolymerization of metharylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) in the presence of isoniazid template molecules. A novel flow injection chemiluminescence sensor for isoniazid determination is developed by packing the isoniazid-MIP into the flow cell as recognition elements. Isoniazid could be selectively adsorbed by the MIPs and the adsorbed isoniazid was sensed by its great enhancing effect on the weak CL reaction between luminol and periodate which were mixed in the flow cell. The enhanced CL intensity is linear in the range 2x10(-9) to 2x10(-7) g/mL and the detection limit is 7x10(-10) g/mL (3sigma) isoniazid with a relative standard deviation 2.8% (n=9) for 8x10(-8) g/mL. The sensor is reversible and reusable. It has a great improvement in sensitivity and selectivity for CL analysis. As a result, the sensor has been successfully applied to determination of isoniazid in human urine. At the same time, the binding characteristic of the polymer to isoniazid was evaluated by batch method and the dynamic method, respectively.  相似文献   

9.
流动注射化学发光法测定白藜芦醇苷   总被引:4,自引:0,他引:4  
基于白藜芦醇苷对Luminol KIO4 H2O2体系化学发光的抑制作用,建立了一种快速测定白藜芦醇苷的流动注射化学发光分析法。测定白藜芦醇苷的线性范围为2.0×10-8~8.8×10-6mol L;检出限为6.7×10-9mol L;相对标准偏差为1.9%(c白藜芦醇苷=4.4×10-7mol L,n=11);采样频率为144次 h。该方法可用于葡萄酒和中药虎杖中白藜芦醇苷的测定。  相似文献   

10.
Liang YD  Song JF  Yang XF  Guo W 《Talanta》2004,62(4):757-763
A new flow-injection chemiluminescence (CL) method for determination of chloroquine is proposed based on a stronger chemiluminescence of chloroquine in hydrogen peroxide-nitrite-sulfuric acid medium. The proposed method allows the measurement of chloroquine over the range of 3.0×10−7 to 1.0×10−5 mol l−1. The detection limit is 8.6×10−8 mol l−1, and the relative standard deviation for 1.0×10−6 mol l−1 chloroquine (n=11) is 1.6%. The CL mechanism is also discussed.  相似文献   

11.
Comparative studies on the electrogenerated chemiluminescence (ECL) behavior of luminol on various electrodes modified with gold nanoparticles of different size were carried out in neutral solution by conventional cyclic voltammetry (CV). The results demonstrated that the gold nanoparticle modified electrodes could generate strong luminol ECL in neutral pH conditions. The catalytic performance of gold nanoparticle modified electrodes on luminol ECL depended not only on the gold nanoparticles but also on the substrate. Gold electrode and glassy carbon electrode were the most suitable substrates for the self-assembly of gold nanoparticles. Moreover, the gold nanoparticle modified gold and glassy carbon electrode had satisfying stability and reproducibility and did not need tedious pretreatment of electrode surface before each measurement. It was also found that luminol ECL behavior depended on the size of gold nanoparticles. The most intense ECL signals were obtained on a 16-nm-diameter gold nanoparticle modified electrode. The modified electrode prepared by the self-assembly method exhibited much better catalytic effect on luminol ECL than that prepared by the electrically deposited method. The ECL behavior of luminol on a gold nanoparticle self-assembled gold electrode was also investigated by other transient-state electrochemical techniques, such as chronoamperometry, differential pulse voltammetry, normal pulse voltammetry, and square wave voltammetry. The strongest ECL intensity was obtained under square wave voltammetric condition.  相似文献   

12.
Horseradish peroxidase (HRP) encapsulated in liposomes was directly detected by using luminol chemiluminescence (CL) with H2O2 without lysis of liposomes. At a low concentration of H2O2, the initial rate of HRP-catalyzed luminol CL in liposomes was slower than that of HRP-catalyzed luminol CL in a lipid-free bulk solution. The decrease in the initial rate of the CL reaction in liposomes was due to the membrane permeation of luminol and H2O2. At a high concentration of H2O2, the initial rate of the CL reaction in liposomes was the same as that in a lipid-free bulk solution. The CL measurement conditions in both a lipid-free bulk solution and in liposomes were optimized in the concentrations of luminol and H2O2 by measuring the CL response curves, in which only one peak appeared and the CL intensity was maximal. The CL intensity observed in HRP-catalyzed luminol CL in liposomes was a factor of seven greater than that observed in a lipid-free bulk solution. The CL intensity was dependent on the amount of HRP-encapsulated liposomes used. The detection limit in the direct detection of HRP encapsulated in liposomes was sensitive by a factor of 3 compared with that in HRP-catalyzed luminol CL in a lipid-free bulk solution.  相似文献   

13.
The mechanism of the electrogenerated chemiluminescence of luminol in aqueous alkaline solution based on the rotating ring—disc electrode system is discussed. The disc electrode is maintained at a negative potential and the ring electrode at a symmetrically changing double-step potential. Hydrogen peroxide generated at the disc electrode by the reduction of oxygen is immediately transported to the ring electrode because of electrode rotation. Hydrogen peroxide and luminol are oxidized at the ring electrode during the positive pulse of the double-step potential. These oxidation processes generate a superoxide radical and a luminol radical as intermediates. The luminol radical reacts with the superoxide radical (or oxygen) emitting light.  相似文献   

14.
A new apparatus based on the rotating ring—disc electrode system is described. The symmetric double-step potential is connected to the ring electrode to oxidize luminol, while the disc electrode is maintained at a negative potential to reduce oxygen to hydrogen peroxide. Because of the electrode rotation, hydrogen peroxide is immediately transported to the ring electrode at which it reacts with luminol oxidation product to emit light. Preliminary electrogenerated chemiluminescence measurements indicate that the intensity of the chemiluminescence of luminol is highly dependent on the ring and disc electrode materials and that some metal ions have a catalytic or inhibitive effect on this luminescence reaction of luminol.  相似文献   

15.
Li S  Li X  Xu J  Wei X 《Talanta》2008,75(1):32-37
It was found that gold nanoparticles with different sizes could enhance the chemiluminescence (CL) of the luminol-NaIO4 system in alkaline solution. The most intensive CL signals were obtained with gold nanoparticles in diameter of 4 nm and the CL intensity increased linearly with the concentration of gold nanoparticles. The studies of UV-vis spectra, CL spectra, effects of concentrations of luminol and periodate solution were carried out to explore the CL enhancement mechanism. Catechol, hydroquinone and resorcinol were found to inhibit the CL signals of the luminol-NaIO4 reaction catalyzed by gold nanoparticles, which made it applicable for the determination of these polyphenols. Under the selected experimental conditions, the detection limits (3sigma) were in the range of 2.1 x 10(-9) to 1.0 x 10(-10) g ml(-1), the relative standard deviation (R.S.D., n=11) were in the range of 1.7-2.9%. The method has been successfully applied to the determination of catechol in tap water and synthesized samples with satisfactory results.  相似文献   

16.
A rapid and sensitive flow-injection chemiluminescence method is described for the determination of dichloro- and trichloroisocyanuric acids based on the chemiluminescence produced during their reaction with luminol in alkaline medium. The effects of analytical and flow-injection variables on these chemiluminescence systems and determination of both oxidants are discussed. The optimized method yielded 3sigma detection limits of 8x10(-8) and 5x10(-8) mol L(-1) for the sodium dichloroisocyanurate and trichloroisocyanuric acid, respectively. The optimum conditions were found to be as follows: NaOH, 1x10(-1) mol L(-1); luminol, 5x10(-3) mol L(-1); KI, 2x10(-3) mol L(-1) and flow rate, 3.5 mL min(-1).  相似文献   

17.
Flow-injection post chemiluminescence determination of atropine sulfate   总被引:1,自引:0,他引:1  
A new post chemiluminescence (PCL) reaction was observed when atropine sulfate was injected into the reaction mixture after the finish of CL reaction of Ce(IV) and sodium sulfite. The possible mechanism for the PCL reaction was discussed via the investigation of the CL kinetic characteristics, the CL spectra, the UV absorption spectra and the fluorescence spectra of some related substances. The flow injection PCL method for the determination of atropine sulfate was established. The relative standard deviation (R.S.D.) was 2.8% (n = 11, c = 5.0 × 10−6 g mL−1). The PCL intensity responded linearly to the concentration of atropine sulfate in the range 1.0 × 10−6 to 5.0 × 10−5 g mL−1 with a linear correlation of 0.9947. The detection limit was 4 × 10−7 g mL−1 atropine sulfate. The method had been applied to the determination of atropine sulfate in the tablets and the results were consistent with the method of Chinese pharmacopoeia.  相似文献   

18.
A modification of the Trautz-Schorigin reaction into a flow-injection analysis configuration is described. Different approaches were used at the optimization of chemiluminescence determination of formaldehyde in water based on the reaction of formaldehyde, gallic acid and hydrogen peroxide in an alkaline solution. Detection system with a 218 μl chemiluminescence cell was optimized by both a one-variable-at-a-time method, and a modified simplex method. A calibration graph is linear in the concentration range 4 × 10−8 to 1 × 10−5 M HCHO. The detection limit of formaldehyde for a signal-to-noise ratio of 3 is 4 × 10−8 M. The relative standard deviations for 15 repeated measurements of 1 × 10−6 and 5 × 10−6 mol l−1 HCHO are 4.32 and 3.33%, respectively. The analysis time is 1.5 min. The method was applied to the determination of formaldehyde in urban rainwater. A comparison of results found by proposed method with those obtained by fluorimetric reference method provided a good agreement.  相似文献   

19.
As an analytical support, paper, being low cost, highly abundant, of high porosity, disposable or biodegradable, and easy to use, store, transport, and print, has excellent chemical compatibility with many applications. Since the first microfluidic paper-based analytical device (μ-PAD or lab-on-paper) was proposed, the paper-based assay has never attracted as much attention as it does now. There has recently been rapidly increasing interest in using sensitive luminescence methods, for example chemiluminescence (CL) and electrogenerated chemiluminescence (ECL), as the detection strategy for lab-on-paper devices. Because of their intrinsic characteristics, CL and ECL provide outstanding performance while retaining the simplicity, low cost, multifunctionality, versatility, flexibility, and disposability of μ-PADs. The objective of this review is to cover the development of lab-on-paper-based devices using CL and ECL detection, including fabrication of paper devices, construction of sensing interfaces, signal amplification strategies, external instruments used, and applications. We believe that lab-on-paper devices with CL and ECL detection methods will meet the diverse requirements of point-of-care diagnosis.  相似文献   

20.
流动注射化学发光法测定水中的苯胺   总被引:3,自引:0,他引:3  
基于在多聚磷酸介质中,KMnO4氧化苯胺能产生强化学发光,建立了流动注射化学发光测定苯胺的新方法.在优化条件下,化学发光强度ⅠCL与苯胺的浓度在2.0×10~1.0×10-6 mol/L范围内呈良好的线性关系,回归方程为ⅠCL=63.11 2.37×108c(r=0.9997,n=9),检出限为5.0×10-10 mol/L,对1.0×10-7 mol/L苯胺进行11次测定,其相对标准偏差为0.8%(n=11).已用于环境水体中苯胺的测定,回收率在95.1%~105.1%之间.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号