首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 71 毫秒
1.
An FI-ICP-AES method for the determination of trace levels of mercury in biological samples has been described, which is based on the extraction of the mercury complex with 1,5-bis (di-2-pyridyl)methylene thiocarbonohydrazide (DPTH) on-line into isobuthyl-methyl ketone (IBMK). The organic phase (containing the complex) has been mixed on-line with SnCl2 in N,N-dimethylformamide. Thus, mercury vapour can be generated directly from the organic phase and separated in a gas-liquid separation device. The detection limit for mercury is 4 ng/ml and the calibration curve is linear at least from 10 to 2500 ng/ml. The relative standard deviation for 10 replicate measurements is ±1% for 100 ng/ml of Hg(II). Results from the analysis of some certified biological reference materials are given.  相似文献   

2.
A highly selective spectrofluorometric method for the determination of total mercury (Hg) in waste waters is described. Fluorescence quenching of rhodamine B with Hg(II) in the presence of iodide, after a concentration step, is the basis of this sensitive method. All forms of mercury, including organic compounds, are pre-oxidized to ionic mercury by acidic potassium permanganate. The final and complete oxidation is achieved by adding potassium persulphate and heating. Hg(II) was reduced by tin(II) chloride and Hg vapour driven by an air stream into an absorption solution containing potassium permanganate and sulphuric acid, using a closed, recirculating air stream. In this solution fluorescence quenching of rhodamine B at an excitation wavelength of 485 nm and emission wavelength of 586 nm was measured. The recoveries were done by adding 3.0 g Hg/100 ml to each sample before the digestion. It was indicated that the recoveries for determining mercury in waste waters were 98.3%–102.7%. The method gives reliable results down to a concentration of 10 ng Hg/ml waste water.  相似文献   

3.
《Analytical letters》2012,45(13):2217-2230
Abstract

(Acetylacetone)‐2‐thiol‐phenyleneimine (H2L) immobilized on an anion‐exchange resin (Dowex) was used for separation and removal of mercury from natural water samples and for preconcentration prior to its determination by cold vapor inductively coupled plasma atomic emission spectroscopy. The metal was eluted from the column using a solution of 10% thiourea in 0.1 M HCl. The modified resin is higly selective with an exchange capacity of 1.60 mmol g?1. Various parameters like pH, column flow rate, and desorbing agents are optimized. The proposed method has a linear calibration range of 15–1000 ng/ml Hg(II), with a relative standard deviation at the 15 ng/ml level of 3.5%. The precision of the method (evaluated as the relative standard deviation obtained after analyzing six series of five replicates) was ±4.2% at the 50 ng/ml level of Hg(II). The method has been used for routine determination of trace levels of mercury species in natural waters. The potential application of modified resin for the removal of mercury(II) from two natural water samples (top water and lake water) spiked with 50 ng/ml of mercury (II) was studied by ICP‐AES, and the results proved that excellent percent extraction of mercury(II) from both natural water samples was obtained by column method using modified resin.  相似文献   

4.
5.
1,5-Bis[(2-pyridyl)-3-sulphophenyl methylene] thiocarbonohydrazide (PSTH) immobilized on an anion-exchange resin (Dowex) has been used for the on-line preconcentration of mercury from biological samples and waters prior to its determination by inductively coupled plasma atomic emission spectroscopy. The metal was eluted from the column using a solution of 2 M HNO(3) and mixed on-line with SnCl(2). The optimum experimental conditions were evaluated for the continuous preconcentration of Hg, the direct generation of mercury vapour and the final determination of this element by ICP-AES. The enrichment, together with low blank levels of the optimized procedure, allow the simple determination of this toxic element at concentrations down to a few nanograms per milliliter. The proposed method has a linear calibration range 5-1000 ng ml(-1) of mercury, with a detection limit of 4 ng ml(-1) (S/N=3) and a sampling rate of 40 h(-1), investigated with a 9 ml sample volume. The precision of the method (evaluated as the relative standard deviation obtained after analyzing ten series of ten replicates) was +/-3.6% at the 10 ng ml(-1) level of Hg(II) and +/-1.3% at the 100 ng ml(-1) level. The accuracy of the method was examined by the analysis of certified reference materials.  相似文献   

6.
A flow-injection analysis atomic absorption spectrometric (FIA-AAS) method was developed for the determination of trace amounts of arsenic, selenium and mercury in a proposed estuarine sediment standard reference material (SRM 1646a). The samples were prepared in two manners: a) A wet digestion procedure with HNO3, H2SO4, and HClO4 using a reflux column and b) A microwave-oven digestion procedure utilizing HNO3, H2SO4, and HCl for As and Se, and HNO3 for Hg. Microwave-oven digestion provides results comparable to those found by reflux column digestion and reduces the sample preparation time by a factor of 10. The proposed method employing the microwave-oven digestion procedure coupled with FIA-AAS for As and Se, and FIA-CVAAS for Hg, has detection limits of 0.15 ng As/ml, O.17 ng Se/ml and 0.15 ng Hg/ml.On leave from the Defense Metallurgical Research Laboratory, Hyderabad, India  相似文献   

7.
A sensitive and selective indirect determination of iodide by inductively coupled plasma emission spectrometry (ICP-AES) based on the principle of tandem on-line continuous separations as an alternative means of introducing samples into plasmas is proposed. Iodide is continuously extracted as an ion-pair into xylene by mixing the sample with Hg(II) and dipyridil solutions. The organic phase (containing the analyte in [Hg(Dipy)2]I2 form) is on-line continuously mixed with NaBH4 (in DMF) and acetic acid solutions. Mercury vapour continuously generated from this organic phase is separated in a classical U-type gas-liquid separation device. The system has been optimized for the continuous extraction of KI, for the direct generation of cold mercury vapour from xylene and for the final ICP-AES determination of mercury. The optimised method has been applied to the determination of iodide (detection limit 20 ng/ml of iodide) in table salt and in synthetic samples. Very good agreement between found and certified results was observed. The usefulness and convenience of such alternative sample chemical pretreatment/presentation to the ICP is thus demonstrated for indirect determinations to be carried out by atomic spectroscopy methods.  相似文献   

8.
Two pretreatment procedures for total mercury determinations in natural water samples were compared. The first, the Swedish Standard method (DP1), involves digestion of water in the presence of concentrated nitric acid at 120°C and under pressure for 30 min. In the West German Standard method (DP2), small volumes of nitric and sulphuric acids, permanganate and peroxodisulphate are added to the sample, and digestion proceeded at 50°C in an ultrasonic bath. Mercury was determined after both digestion procedures using a modified cold vapour atomic absorption spectrometric method, in which mercury generated on addition of a reducing agent is collected and subsequently atomized in a platinum-lined graphite furnace. The efficacy of the two digestion procedures was tested using various standard organic mercury compounds and it was found that only DP2 provided quantitative recoveries. Purification of the reagents required by DP2 was achieved using a mercury-selective ion-exchange resin, Chelite S, resulting in blank levels below 1.5 ng Hg l?1. Both methods were applied to the determination of total mercury in an unpolluted marsh water sample, giving 2.0 ng Hg l?1 (DP1) and 2.7 ng Hg l?1 (DP2). The West German Standard digestion procedure (DP2) is recommended for the determination of total mercury in natural water samples.  相似文献   

9.
The determination of Hg using different variants of the Furnace Atomic Nonthermal Excitation Spectrometry (FANES) is described. In the direct analysis of micro volumes of solutions, the results could be improved by working with chemical modifiers for the stabilization of Hg during the thermal pretreatment. The best results were obtained using Ir and Pd as modifiers, with absolute detection limits of 4 and 12 pg, respectively. The determination of mercury in sample volumes up to 10 ml could be achieved by coupling a cold vapour generation system and an amalgam attachment to the FANES source. A detection limit of 22 was obtained with this technique. The best results were obtained by using the cold vapour generation technique and in situ enrichment of Hg onto the modified inner surface of the graphite tube of the FANES source. Using Ir for permanent impregnation of the tube a detection limit of 0.0009 was found. The influence of hydride forming elements on the determination of mercury by the technique of vapour generation and in situ enrichment was studied. A reduction of the concentration of NaBH4 to 0.002% m/v made it possible to determine traces of mercury in presence of a high excess of hydride forming elements without any depression of the Hg emission intensity.The results were validated using standard reference materials.  相似文献   

10.
A fully automated system for the direct determination of methylmercury (MeHg), ethylmercury (EtHg), phenylmercury (PhHg), and inorganic mercury (Hg(II)) at the ng/L level is described. It is based on solid phase extraction preconcentration incorporated in a flow injection (FI) system, high performance liquid chromatography (HPLC) separation, reduction combined with thermolysis and determination by cold vapour atomic absorption spectrometry (CVAAS). For preconcentration a microcolumn of bonded silica with octadecyl functional groups (C18 reversed phase material) was used as a sorbent for the mercury complexes formed on-line with ammonium pyrrolidine dithiocarbamate. Retained mercury species are eluted with a methanol-acetonitrile-water mixture and subjected to separation on an octadecylsilane (ODS) column before determination by CVAAS. The sensitivity of organo-mercury determination could be improved by using NaBH4 as a reductant combined with a thermolysis step. In order to perform on-line measurements the preconcentration microcolumn was mounted in a pressure-tight casing. Limits of detection for MeHg, EtHg, PhHg and Hg(II) employing a sample volume of 58.5 mL were 9, 6, 10 and 5 ng/L, respectively. The relative standard deviation (RSD) calculated from 9 repeated measurements was found to be 3.6%, 5.5%, 10.4% and 7.6% for MeHg, EtHg, PhHg and Hg(II), respectively. Finally, the application of this method for speciation of mercury in fish and human urine is described.  相似文献   

11.
A fully automated system for the direct determination of methylmercury (MeHg), ethylmercury (EtHg), phenylmercury (PhHg), and inorganic mercury (Hg(II)) at the ng/L level is described. It is based on solid phase extraction preconcentration incorporated in a flow injection (FI) system, high performance liquid chromatography (HPLC) separation, reduction combined with thermolysis and determination by cold vapour atomic absorption spectrometry (CVAAS). For preconcentration a microcolumn of bonded silica with octadecyl functional groups (C18 reversed phase material) was used as a sorbent for the mercury complexes formed on-line with ammonium pyrrolidine dithiocarbamate. Retained mercury species are eluted with a methanol-acetonitrile-water mixture and subjected to separation on an octadecylsilane (ODS) column before determination by CVAAS. The sensitivity of organo-mercury determination could be improved by using NaBH4 as a reductant combined with a thermolysis step. In order to perform on-line measurements the preconcentration microcolumn was mounted in a pressure-tight casing. Limits of detection for MeHg, EtHg, PhHg and Hg(II) employing a sample volume of 58.5 mL were 9, 6, 10 and 5 ng/L, respectively. The relative standard deviation (RSD) calculated from 9 repeated measurements was found to be 3.6%, 5.5%, 10.4% and 7.6% for MeHg, EtHg, PhHg and Hg(II), respectively. Finally, the application of this method for speciation of mercury in fish and human urine is described. Received: 10 March 1997 / Revised: 29 January 1998 / Accepted: 5 February 1998  相似文献   

12.
A comparative study of three mercury chelate forming reagents [diethyldithiocarbamate, pyrrolidin-1-yldithioformate and diphenylthiocarbazone (dithizone)] has been carried out for the preconcentration of ultratrace amounts of inorganic mercury and methylmercury in silica C(18) minicolumns as the solid sorbent. Sample flow injection in-line sorbent extraction was coupled with continuous cold vapour atomic absorption spectrometry (CVAAS) for detection. Results showed the superiority of the carbamate type reagents over the dithizone for the on-line formation and preconcentration of the corresponding mercury chelates. Using diethyldithiocarbamate (DDC) as reagent, aqueous sample volumes of 100 ml can be preconcentrated with 100% efficiency for both inorganic mercury and methylmercury. Quantitative release of the retained DDC chelates was obtained for volumes of eluent (ethanol) of 50 microl. Following the proposed procedure, detection limits of 16 ng/l. of mercury were achieved for sample volumes of 25 ml. The relative standard deviation was +/- 3.4% at 0.5 microg/l. Hg(II) levels. The method has been successfully applied to the determination of low levels of mercury in sea-water.  相似文献   

13.
Bagheri H  Gholami A 《Talanta》2001,55(6):681-1150
A new, simple and sensitive method for the simultaneous determination of mercury(II) and methylmercury chloride at sub-ng l−1 levels in river waters is described. Inorganic and organic mercury were preconcentrated from fresh water samples simultaneously on a laboratory-made column containing 2-mercaptobenzimidazol loaded on silica gel and then quantitatively eluted with 0.05 M KCN solution and 2.0 M HCl to desorp inorganic and methylmercury species, respectively. After irradiation with an intensive UV source, MeHg+ was decomposed and mercury vapours were generated from inorganic and organic mercury using an acidic SnCl2 solution in a continuous flow system and were subsequently determined with a cold vapour atomic fluorescence (CV-AFS) spectrometer. Detection limits (3σ) were 0.07 and 0.05 ng l−1 (as Hg) for mercury(II) chloride and methylmercury chloride, respectively. Relative standard deviations of method (%R.S.D.) were 8.8 and 10 for inorganic and organomercuric species in the river water, respectively. The analysis of real samples, taken from different rivers, showed that inorganic mercury levels ranged from 4.0±0.6 to 12±1 ng l−1 (as Hg and 95% confidence limit) and methylmercury levels at 0.2±0.02 ng l−1(as Hg).  相似文献   

14.
Because of the toxicity and mobility of organic mercury, there is a need for determination of organic and inorganic mercury at very low concentrations in the environment, especially in seawater. A procedure for extraction and determination of low concentrations of the different states of mercury - total, inorganic, and organic - in seawater, by cold vapour atomic absorption spectroscopy (CVAAS) is described.Inorganic mercury only was directly reduced to the Hg(0) state by tin(II) chloride under strongly acid conditions (H(2)SO(4)) and mercury metal (Hg(0)) was determined by cold vapour atomic absorption spectroscopy. Organic and inorganic mercury were extracted, with toluene, as the bromide derivatives and re-extracted, together, into ammonium chloride solution. Organic mercury was converted into inorganic mercury by thermal digestion at 80-90 degrees C in the presence of strong oxidants. These two states of mercury were determined together as total mercury. Inorganic mercury was measured directly after pre-concentration of the sample by toluene extraction. Toluene dissolved in aqueous phase after re-extraction of the sample was removed by heating for 30 min at 80-90 degrees C. Organic mercury was calculated as the difference between total and inorganic mercury.The sensitivity of the method is 0.0001 ng mL(-1) Hg, depending on sample volume.  相似文献   

15.
A novel crosslinked chitosan (CCTS) has been synthesized by the reaction of water-soluble chitosan with epoxy chloropropane. In the presence of the chelating EDTA and in the pH range between 4–10, CCTS selectively adsorbed trace inorganic Hg in water samples with enrichment factors of 100. Inorganic Hg could be directly reduced using KBH4 without preceding elution and determined by CVAAS. Accordingly, the total mercury could be determined after all species of mercury in water samples were transformed into Hg2+. The detection limit (3σ) for mercury was 12 ng L–1 and the relative standard deviation less than 5% at the 50 ng L–1 level. Beer’s law was obeyed over the range 30–400 ng L–1 of mercury and the preconcentration method was applied to environmental water samples with the recoveries between 92–96%.  相似文献   

16.
Abstract

A new spectrophotometric FIA method for total mercury determination in water is proposed for the 5-40ng ml range. The method is based on the inhibitory effect of Hg(II) in the catalytic action of iodides on the As(III)-Ce(IV) reaction. By means of preconcentration techniques using KMnO4 traps, ppt levels of mercury in water can be detected.  相似文献   

17.
A simple and robust time-based on-line sequential injection system for trace mercury determination via cold vapour atomic absorption spectrometry (CVAAS), employing a new integrated gas-liquid separator (GLS), which in parallel operates as reactor, was developed. Sample and reductant are sequentially loaded into the GLS while an argon flow delivers the released mercury vapour through the atomic absorption cell. The proposed method is characterized by the ability of successfully managing variable sample volume up to 30 ml in order to achieve high sensitivity. For 20 ml sample volume, the sampling frequency is 25 h−1. The calibration curve is linear over the concentration range 0.05-5.0 μg l−1 of Hg(II), the detection limit is cL = 0.02 μg l−1, and the relative standard deviation is sr = 2.6% at 1.0 μg l−1 Hg(II) level. The performance of the proposed method was evaluated by analyzing certified reference material and applied to the analysis of natural waters and biological samples.  相似文献   

18.
A simple and accurate method has been developed for the determination of total mercury in environmental and biological samples. The method utilises an off-line microwave digestion stage followed by analysis using a flow injection system with detection by cold vapour atomic absorption spectrometry.

The method has been validated using two certified reference materials (DORM-1 dogfish and MESS-2 estuarine sediment) and the results agreed well with the certified values. A detection limit of 0.2 ng g−1 Hg was obtained and no significant interference was observed. The method was finally applied to the determination of mercury in river sediments and canned tuna fish, and gave results in the range 0.1–3.0 mg kg−1.  相似文献   


19.
A method for the determination of mercury in workplace environments in a chlor-alkali plant was optimized. Mercury was collected on activated carbon with a personal sampling pump at a flow-rate of 0.5 l/min, then the carbon was mineralized by heating with potassium permanganate and sulphuric acid. The mercuric ion was next chelated with ammonium pyrrolidinedithiocarbamate and extracted with methyl isobutyl ketone at acidic pH (1.6–5). The chelate in the extract was decomposed with sulphuric acid and the mercuric ion reduced to the metal with stannous chloride. The mercury was determined by coldvapour atomic-absorption spectrometry (CVAAS). The calibration graph was linear up to 5 ng/ml Hg in the initial solution, the relative standard deviation was 4.5% (for 2 ng/ml) and the detection limit was 0.14 ng/ml. All the figures of merit are referred to the initial sample. The proposed method gave good accordance with CVAAS without extraction.  相似文献   

20.
Hafez MA  Kenawy IM  Akl MA  Lashein RR 《Talanta》2001,53(4):749-760
The use of chemically modified chloromethylated polystyrene-PAN, CMPS-PAN (ion-exchanger) for the preconcentration and separation of total mercury after digestion in preparation for determination by cold vapour atomic absorption spectrometry (CVAAS) was described. The effects on the percentage of recovered mercury by mass change of ion-exchanger, stirring time, pH of the solution samples and eluent concentration were studied. The distribution coefficient K(d) is 10(6.6) ml g(-1). The interfering effects of some foreign ions were described. The metal complex formed between CMPS-PAN ion-exchanger and mercury was characterized by IR spectroscopy, pH-metric titration and thermal analysis. The method is simple and rapidly applicable for the determination of total mercury (ng ml(-1)) in natural water, milk and urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏