首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Sodium MRI has been shown to be highly specific for glycosaminoglycan (GAG) content in articular cartilage, the loss of which is an early sign of osteoarthritis (OA). Quantitative sodium MRI techniques are therefore under development in order to detect and assess early biochemical degradation of cartilage, but due to low sodium NMR sensitivity and its low concentration, sodium images need long acquisition times (15-25 min) even at high magnetic fields and are typically of low resolution. In this preliminary study, we show that compressed sensing can be applied to reduce the acquisition time by a factor of 2 at 7 T without losing sodium quantification accuracy. Alternatively, the nonlinear reconstruction technique can be used to denoise fully-sampled images. We expect to even further reduce this acquisition time by using parallel imaging techniques combined with SNR-improved 3D sequences at 3T and 7 T.  相似文献   

2.
使用超声研究关节软骨的深度依赖瞬态膨胀行为   总被引:1,自引:0,他引:1       下载免费PDF全文
关节软骨是覆盖关节表面的一层承载生物重量的组织,关节软骨在正常状态下,软骨蛋白多糖的弹性和胶原纤维的张力保持平衡。这种平衡的微小变化会引起关节软骨的退化。量化关节软骨,特别是在表层区域的膨胀影响,可以表征骨关节炎的退化变化。本文的主要目的是使用一种新的实时超声膨胀测量系统来研究在改变浸泡关节软骨的盐水浓度,以及改用胰岛素溶液时的关节软骨的深度依赖瞬态膨胀行为。  相似文献   

3.
High pressure-frozen (HPF), freeze-fractured and freeze-dried rat cerebellum was analyzed with imaging TOF-SIMS equipped with a Bi-cluster ion source. Data were collected separately as spectra of high mass resolution mm > 8000 and images of high lateral resolution <700 nm. Images were made showing the localization of the peaks m/z = 22.99, and m/z = 39.1.Topographical effects were noted due to the freeze fracture method. This effect was compensated by normalizing images of specific secondary ions to the intensity of total secondary ions and by making PCA analysis of the image. The results showed that potassium ions were localized in blood vessels and cortex cells and sodium ions were localized in blood vessels and cerebellar interstitial tissue and in the nuclei of some cells. The sodium ion concentration was found to be higher in blood vessels than in the interstitium.  相似文献   

4.
In the present work we introduced two MRI rotating frame relaxation methods, namely adiabatic T and Relaxation Along a Fictitious Field (RAFF), along with an inversion-prepared Magnetization Transfer (MT) protocol for assessment of articular cartilage. Given the inherent sensitivity of rotating frame relaxation methods to slow molecular motions that are relevant in cartilage, we hypothesized that adiabatic T and RAFF would have higher sensitivity to articular cartilage degradation as compared to laboratory frame T2 and MT. To test this hypothesis, a proteoglycan depletion model was used. Relaxation time measurements were performed at 0 and 48 h in 10 bovine patellar specimens, 5 of which were treated with trypsin and 5 untreated controls were stored under identical conditions in isotonic saline for 48 h. Relaxation times measured at 48 h were longer than those measured at 0 h in both groups. The changes in T2 and MT relaxation times after 48 h were approximately 3 times larger in the trypsin treated specimens as compared to the untreated group, whereas increases of adiabatic T and RAFF were 4 to 5 fold larger. Overall, these findings demonstrate a higher sensitivity of adiabatic T and RAFF to the trypsin-induced changes in bovine patellar cartilage as compared to the commonly used T2 and MT. Since adiabatic T and RAFF are advantageous for human applications as compared to standard continuous-wave T methods, adiabatic T and RAFF are promising tools for assessing cartilage degradation in clinical settings.  相似文献   

5.
The application of biomolecular magnetic resonance imaging becomes increasingly important in the context of early cartilage changes in degenerative and inflammatory joint disease before gross morphological changes become apparent. In this limited technical report, we investigate the correlation of MRI T1, T2 and T1ρ relaxation times with quantitative biochemical measurements of proteoglycan and collagen contents of cartilage in close synopsis with histologic morphology. A recently developed MRI sequence, T1ρ, was able to detect early intracartilaginous degeneration quantitatively and also qualitatively by color mapping demonstrating a higher sensitivity than standard T2-weighted sequences. The results correlated highly with reduced proteoglycan content and disrupted collagen architecture as measured by biochemistry and histology. The findings lend support to a clinical implementation that allows rapid visual capturing of pathology on a local, millimeter level. Further information about articular cartilage quality otherwise not detectable in vivo, via normal inspection, is needed for orthopedic treatment decisions in the present and future.  相似文献   

6.
Contrast media such as gadolinium-diethlene-triamine pentaacetic acid (Gd-DTPA) is used for MRI. Recently there have been some reports about diagnosis using contrast media for the MRI T(1) image for the quantitative evaluation of articular cartilage degeneration. This may be a useful method to evaluate the lesion of the articular cartilage or to confirm therapeutic progress. Whether or not contrast is used, the use of the calculated T(1) image is effective for the quantitative evaluation of the degeneration of knee joint cartilage. However, our system copes with the format of every MRI image even if software of the calculated T(1) image isn't often prepared in the commercial MRI device. So, we developed general purpose image data processing software that can be processed on the preexisting three-dimensional image data processing system.  相似文献   

7.
Laser shock processing (LSP) has been proposed as a competitive alternative technology to classical treatments for improving fatigue and wear resistance of metals. We present a configuration and results for metal surface treatments in underwater laser irradiation at 1064 nm. A convergent lens is used to deliver 1.2 J/cm2 in a 8 ns laser FWHM pulse produced by 10 Hz Q-switched Nd:YAG, two laser spot diameters were used: 0.8 and 1.5 mm.Results using pulse densities of 2500 pulses/cm2 in 6061-T6 aluminum samples and 5000 pulses/cm2 in 2024 aluminum samples are presented. High level of compressive residual stresses are produced −1600 MPa for 6061-T6 Al alloy, and −1400 MPa for 2024 Al alloy. It has been shown that surface residual stress level is higher than that achieved by conventional shot peening and with greater depths. This method can be applied to surface treatment of final metal products.  相似文献   

8.
Sodium magnetic resonance (MR) imaging is a promising technique for detecting changes of proteoglycan (PG) content in cartilage associated with knee osteoarthritis. Despite its potential clinical benefit, sodium MR imaging in vivo is challenging because of intrinsically low sodium concentration and low MR signal sensitivity. Some of the challenges in sodium MR imaging may be eliminated by the use of a high-sensitivity radiofrequency (RF) coil, specifically, a dual-tuned (DT) proton/sodium RF coil which facilitates the co-registration of sodium and proton MR images and the evaluation of both physiochemical and structural properties of knee cartilage. Nevertheless, implementation of a DT proton/sodium RF coil is technically difficult because of the coupling effect between the coil elements (particularly at high field) and the required compact design with improved coil sensitivity. In this study, we applied a multitransceiver RF coil design to develop a DT proton/sodium coil for knee cartilage imaging at 3 T. With the new design, the size of the coil was minimized, and a high signal-to-noise ratio (SNR) was achieved. DT coil exhibited high levels of reflection S11 (~-21 dB) and transmission coefficient S12 (~-19 dB) for both the proton and sodium coils. High SNR (range 27-38) and contrast-to-noise ratio (CNR) (range 15-21) were achieved in sodium MR imaging of knee cartilage in vivo at 3-mm(3) isotropic resolution. This DT coil performance was comparable to that measured using a sodium-only birdcage coil (SNR of 28 and CNR of 20). Clinical evaluation of the DT coil on four normal subjects demonstrated a consistent acquisition of high-resolution proton images and measurement of relative sodium concentrations of knee cartilages without repositioning of the subjects during the same MR scanning session.  相似文献   

9.

Purpose

The articular cartilage is a small tissue with a matrix structure of three layers between which the orientation of collagen fiber differs. A diffusion-weighted twice-refocused spin-echo echo-planar imaging (SE-EPI) sequence was optimized for the articular cartilage, and the structure of the three layers of human articular cartilage was imaged in vivo from diffusion tensor images.

Materials and Methods

The subjects imaged were five specimens of swine femur head after removal of the flesh around the knee joint, five specimens of swine articular cartilage with flesh present and the knee cartilage of five adult male volunteers. Based on diffusion-weighted images in six directions, the mean diffusivity (MD) and the fractional anisotropy (FA) values were calculated.

Results

Diffusion tensor images of the articular cartilage were obtained by sequence optimization. The MD and FA value of the specimens (each of five examples) under different conditions were estimated. Although the articular cartilage is a small tissue, the matrix structure of each layer in the articular cartilage was obtained by SE-EPI sequence with GRAPPA. The MD and FA values of swine articular cartilage are different between the synovial fluid and saline. In human articular cartilage, the load of the body weight on the knee had an effect on the FA value of the surface layer of the articular cartilage.

Conclusion

This method can be used to create images of the articular cartilage structure, not only in vitro but also in vivo. Therefore, it is suggested that this method should support the elucidation of the in vivo structure and function of the knee joint and might be applied to clinical practice.  相似文献   

10.

Purpose

To present preliminary, in vivo temperature measurements during MRI of a pig implanted with a deep brain stimulation (DBS) system.

Materials and Methods

DBS system (Medtronic Inc., Minneapolis, MN) was implanted in the brain of an anesthetized pig. 3.0-T MRI was performed with a T/R head coil using the low-SAR GRE EPI and IR-prepped GRE sequences (SAR: 0.42 and 0.39 W/kg, respectively), and the high-SAR 4-echo RF spin echo (SAR: 2.9 W/kg). Fluoroptic thermometry was used to directly measure RF-related heating at the DBS electrodes, and at the implantable pulse generator (IPG). For reference the measurements were repeated in the same pig at 1.5 T and, at both field strengths, in a phantom.

Results

At 3.0 T, the maximal temperature elevations at DBS electrodes were 0.46 °C and 2.3 °C, for the low- and high-SAR sequences, respectively. No heating was observed on the implanted IPG during any of the measurements. Measurements of in vivo heating differed from those obtained in the phantom.

Conclusion

The 3.0-T MRI using GRE EPI and IR-prepped GRE sequences resulted in local temperature elevations at DBS electrodes of no more than 0.46 °C. Although no extrapolation should be made to human exams and much further study will be needed, these preliminary data are encouraging for the future use 3.0-T MRI in patients with DBS.  相似文献   

11.
The aim was to design a pattern-recognition (PR) system for discriminating between normal and pathological knee articular cartilage of the medial femoral (MFC) and tibial condyles (MTC). The data set comprised segmented regions of interest (ROIs) from coronal and sagittal 3-T magnetic resonance images of the MFC and MTC cartilage of young patients, 28 with abnormality-free knee and 16 with pathological findings. The PR system was designed employing the probabilistic neural network classifier, textural features from the segmented ROIs and the leave-one-out evaluation method, while the PR system's precision to “unseen” data was assessed by employing the external cross-validation method. Optimal system design was accomplished on a consumer graphics processing unit (GPU) using Compute Unified Device Architecture parallel programming. PR system design on the GPU required about 3.5 min against 15 h on a CPU-based system. Highest classification accuracies for the MFC and MTC cartilages were 93.2% and 95.5%, and accuracies to “unseen” data were 89% and 86%, respectively. The proposed PR system is housed in a PC, equipped with a consumer GPU, and it may be easily retrained when new verified data are incorporated in its repository and may be of value as a second-opinion tool in a clinical environment.  相似文献   

12.
The objective of this study was to analyze regional variations of magnetic resonance (MR) relaxation times (T and T2) in hip joint cartilage of healthy volunteers and subjects with femoral acetabular impingement (FAI). Morphological and quantitative images of the hip joints of 12 healthy volunteers and 9 FAI patients were obtained using a 3 T MR scanner. Both femoral and acetabular cartilage layers in each joint were semi-automatically segmented on sagittal 3D high-resolution spoiled gradient echo (SPGR) images. These segmented regions of interest (ROIs) were automatically divided radially into twelve equal sub-regions (300 intervals) based on the fitted center of the femur head. The mean value of T/T2 was calculated in each sub-region after superimposing the divided cartilage contours on the MR relaxation (T/T2) maps to quantify the relaxation times. T and T2 relaxation times of the femoral cartilage were significantly higher in FAI subjects compared to healthy controls (39.9 ± 3.3 msec in FAI vs. 35.4 ± 2.3 msec in controls for T (P = 0.0020); 33.9 ± 3.1 msec in FAI vs. 31.1 ± 1.7 msec in controls for T2 (P = 0.0160)). Sub-regional analysis showed significantly different T and T2 relaxation times in the anterior-superior region (R9) of the hip joint cartilage between subjects with FAI and healthy subjects, suggesting possible regional differences in cartilage matrix composition between these two groups. Receiver operating characteristic (ROC) analysis showed that sub-regional analysis in femoral cartilage was more sensitive in discriminating FAI joint cartilage from that of healthy joints than global analysis of the whole region (T: area under the curve (AUC) = 0.981, P = 0.0001 for R9 sub-region; AUC = 0.901, P = 0.002 for whole region; T2: AUC = 0.976, P = 0.0005 for R9 sub-region; AUC = 0.808, P = 0.0124 for whole region). The results of this study demonstrated regional variations in hip cartilage composition using MR relaxation times (T and T2) and suggested that analysis based on local regions was more sensitive than global measures in subjects with and without FAI.  相似文献   

13.
Established methods for the measurement of articular cartilage thickness are invasive and cannot be sequentially applied in living subjects. In the present study, the distribution of cartilage thickness throughout entire joint surfaces was determined from MR images obtained with a fat-suppressed gradient-echo sequence at a resolution of 0.31 × 0.31 × 2.00 mm3, and compared to that derived from CT arthrography. A minimal distance algorithm was employed to produce 3D cartilage thickness maps of seven cadaveric human knee joints. The mean amount of deviation of the cartilage volumes was 5.6% (±4.6), statistical analysis showing that there was high agreement between the two methods (r = 0.995, slope = 1.037, y-intercept = -90.5 mm3). The 3D thickness maps yielded a striking agreement between the two methods, the maximum values generally yielding a deviation of none or one thickness interval of 0.5 mm. This investigation shows that accurate 3D assessment of articular cartilage thickness can be performed with MRI, this technique having the advantage that it is suitable for investigating living subjects.  相似文献   

14.
MRI is often used to visualize and quantify the articular cartilage layer of load bearing joints affected by degenerative diseases, such as osteoarthritis (OA). Although the role played by the subchondral bone in the etiology and/or progression of OA may be important, the ability to visualize and quantify subchondral bone with MRI has received little attention. In this report we examined the inter-rater and intra-rater reliability of subchondral bone and cartilage thickness measurements from MR images of cadaver femoral head specimens. A 3D-SPGR pulse sequence tuned to eliminate chemical shift artifact through phase cancellation was used to image the specimens. Three raters manually segmented four specimens on two different occasions. Subchondral bone and cartilage thickness measurements were calculated from the segmented images. Inter-rater and intra-rater reliabilities were very high (>.98) for both cartilage and subchondral bone thickness measurements. We conclude that subchondral bone thickness can be measured as reliably as cartilage thickness from MR images.  相似文献   

15.
Experimental investigations on a sodium ion conducting gel polymer electrolyte nanocomposite based on poly(vinylidene fluoride-co-hexafluoropropylene) (PVdF-HFP), dispersed with silica nanoparticles are reported. The gel nanocomposites have been obtained in the form of dimensionally stable, transparent and free-standing thick films. Physical characterization by X-ray diffraction (XRD), Fourier transform Infra-red (FTIR) spectroscopy and Scanning electron microscopy (SEM) have been performed to study the structural changes and the ion-filler-polymer interactions due to the dispersion of SiO2 nanoparticles in gel electrolytes. The highest ionic conductivity of the electrolyte has been observed to be 4.1 × 10−3 S cm− 1 at room temperature with ~ 3 wt.% of SiO2 particles. The temperature dependence of the ionic conductivity has been found to be consistent with Vogel-Tammen-Fulcher (VTF) relationship in the temperature range from 40 to 70 °C. The sodium ion conduction in the gel electrolyte film is confirmed from the cyclic voltammetry, impedance analysis and transport number measurements. The value of sodium ion transport number (tNa+) of the gel electrolyte is significantly enhanced to a maximum value of 0.52 on the 15 wt.% SiO2 dispersion. The physical and electrochemical analyses indicate the suitability of the gel electrolyte films in the sodium batteries. A prototype sodium-sulfur battery, fabricated using optimized gel electrolyte, offers the first discharge capacity of ~165 mAh g− 1 of sulfur.  相似文献   

16.

Background and Purpose

A new neurological implant, the Sensor-Reservoir, was developed to provide a relative measurement of ICP, which permits a noninvasive technique to detect and localize occlusions in ventricular drainage systems and, thus, to identify mechanical damage to shunt valves. The “reservoir” of this device can be used to administer medication or a contrast agent, to extract cerebral spinal fluid (CSF), and with the possibility of directly measuring ICP. The Sensor-Reservoir was evaluated to identify possible MRI-related issues at 1.5-T/64-MHz and 3-T/128-MHz.

Materials and Methods

Standard testing techniques were utilized to evaluate magnetic field interactions (i.e., translational attraction and torque), MRI-related heating, and artifacts at 3-T for the Sensor-Reservoir. In addition, 12 samples of the Sensor-Reservoir underwent testing to determine if the function of these devices was affected by exposures to various MRI conditions at 1.5-T/64-MHz and 3-T/128-MHz.

Results

Magnetic field interactions for the Sensor-Reservoir were not substantial. The heating results indicated a highest temperature rise of 1.8 °C, which poses no patient risks. Artifacts were relatively small in relation to the size and shape of the Sensor-Reservoir, but may interfere diagnostically if the area of interest is near the device. All devices were unaffected by exposures to MRI conditions at 1.5-T/64-MHz and 3-T/128-MHz.

Conclusion

When specific guidelines are followed, the Sensor-Reservoir is “MR conditional” for patients undergoing MRI examinations at 3-T or less.  相似文献   

17.
BACKGROUND: Ultrahigh-field MRI at 8 T offers unprecedented resolution for imaging brain structures and microvasculature. OBJECTIVE: The aim of this study is to apply high-resolution MRI for stroke imaging and to characterize findings at 1.5 and 8 T. METHODS: Seventeen subjects with minor ischemic infarcts were studied using T2-weighted gradient echo (GE) and rapid acquisition with relaxation enhancement (RARE) images at 8 T with resolution up to 200 microm. In 10 subjects, T1- and T2-weighted fast spin echo (FSE) and fluid-attenuated inversion recovery (FLAIR) images were also acquired at 1.5-T MRI. RESULTS: The 8-T images showed infarcts as sharply demarcated areas of high-signal intensity (n=21) and revealed more infarctions than 1.5-T images (n=14) (P<.003). The low-signal intensity areas that surrounded infarctions were suggestive of hemosiderin deposits. The 8-T characteristics of microvessels terminating within the infractions were distinct from normal vasculature. The 8-T images revealed an angioma at the site of a second stroke, not apparent on 1.5-T images. CONCLUSIONS: Ultrahigh-field MRI at 8 T is feasible for stroke imaging. The 8-T MRI visualized infarcts and microvasculature with high resolution, revealing infarcts and vascular pathologies that were not apparent at 1.5 T.  相似文献   

18.
The 1H double-quantum filtered (DQF) NMR and DQF MRI is applied to the joint tissues of rabbits for selective visualization of tendons, menisci and articular cartilage. The 1H DQF NMR selectively filters double-quantum coherence arising from the 1H dipolar interaction of the “bound” water in these tissues. The double-quantum creation time dependency of the DQF signal intensity is determined by the molecular environment of the “bound” water. Therefore, each tissue has a unique creation time at which the DQF signal reaches its maximum intensity, τmax (Achilles tendon: 0.46 ± 0.02 ms, patella: 0.55 ± 0.8 ms, anterior cruciate ligament: 0.60 ± 0.05 ms, meniscus: 0.78 ± 0.02 ms, skin: 0.81 ± 0.07 ms). We have presented the creation-time-contrasted DQF images of the meniscus, patella, foot, and knee joint. Compared with conventional T2*-weighted gradient-echo (GRE) MR images, tendons, ligaments, menisci, and articular cartilage were more clearly seen in the DQF MR images. All these tissues were distinctly discriminated from each other by their creation times. DQF MR images of foot and knee joints can selectively demonstrated tendons, ligaments, and cartilage, which make it easier to understand the complicated anatomic structure of joints. Because the DQF NMR signal intensity and τmax are sensitive to the order structure of the “bound” water, it might be possible to introduce the creation-time dependent-contrast of 1H DQF MR images as a new tool for analyzing the changes in the ordered structure of the tissue.  相似文献   

19.
Three-dimensional (3D) twisted projection imaging (TPI) trajectory has a unique advantage in sodium (23Na) imaging on clinical MRI scanners at 1.5 or 3 T, generating a high signal-to-noise ratio (SNR) with a short acquisition time (∼10 min). Parallel imaging with an array of coil elements transits SNR benefits from small coil elements to acquisition efficiency by sampling partial k-space. This study investigates the feasibility of parallel sodium imaging with emphases on SNR and acceleration benefits provided by the 3D TPI trajectory. Computer simulations were used to find available acceleration factors and noise amplification. Human head studies were performed on clinical 1.5/3-T scanners with four-element coil arrays to verify simulation outcomes. In in vivo studies, proton (1H) data, however, were acquired for concept–proof purpose. The sensitivity encoding (SENSE) method with the conjugate gradient algorithm was used to reconstruct images from accelerated TPI-SENSE data sets. Self-calibration was employed to estimate coil sensitivities. Noise amplification in TPI-SENSE was evaluated using multiple noise trials. It was found that the acceleration factor was as high as 5.53 (corresponding to acceleration number 2×3, ring-by-rotation), with a small image error of 6.9% when TPI projections were reduced in both polar (ring) and azimuthal (rotation) directions. The average noise amplification was as low as 98.7%, or 27% lower than Cartesian SENSE at that acceleration factor. The 3D nature of both TPI trajectory and coil sensitivities might be responsible for the high acceleration and low noise amplification. Consequently, TPI-SENSE may have potential advantages for parallel sodium imaging.  相似文献   

20.
We proposed an AC electric field-assisted novel polishing method for borosilicate glass plate with water-based slurry. It has been found that the applied electric field operates effectively in positioning the slurry with abrasives in the polishing area. In-situ observations also confirmed that the AC electric field affected the motion of slurry. Under optimal polishing conditions, the processing time of borosilicate glass plate was shortened compared to AC electric field free conditions. Furthermore, the polishing removal amount was increased from 14 to 22 μm for a polishing time of 30 min. This suggests that the productivity could be enhanced by 1.5 times by applying electric field during polishing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号