共查询到20条相似文献,搜索用时 15 毫秒
1.
Seong Cho Dana Jones Wilburn E. Reddick Robert J. Ogg R.Grant Steen 《Magnetic resonance imaging》1997,15(10):1133-1143
The goal of this study was to determine the expected normal range of variation in spin-lattice relaxation time (T1) of brain tissue in vivo, as a function of age. A previously validated precise and accurate inversion recovery method was used to map T1 transversely, at the level of the basal ganglia, in a study population of 115 healthy subjects (ages 4 to 72; 57 male and 58 female). Least-squares regression analysis shows that T1 varied as a function of age in pulvinar nucleus (R2 = 56%), anterior thalamus (R2 = 51%), caudate (R2 = 50%), frontal white matter (R2 = 47%), optic radiation (R2 = 39%), putamen (R2 = 36%), genu (R2 = 22%), occipital white matter (R2 = 20%) (all p < 0.0001), and cortical gray matter (R2 = 53%) (p < 0.001). There were no significant differences in T1 between men and women. T1 declines throughout adolescence and early adulthood, to achieve a minimum value in the fourth to sixth decade of life, then T1 begins to increase. Quantitative magnetic resonance imaging provides evidence that brain tissue continues to change throughout the lifespan among healthy subjects with no neurologic deficits. Age-related changes follow a strikingly different schedule in different brain tissues; white matter tracts tend to reach a minimum T1 value, and to increase again, sooner than do gray matter tracts. Such normative data may prove useful for the early detection of brain pathology in patients. 相似文献
2.
Shintaro Ichikawa Utaroh MotosugiTomoaki Ichikawa Katsuhiro SanoHiroyuki Morisaka Tsutomu Araki 《Magnetic resonance imaging》2013
Purpose
To investigate the relationship between estimated glomerular filtration rate (eGFR) and parameters calculated using intravoxel incoherent motion (IVIM) imaging of the kidneys.Materials and Methods
We studied 365 patients, divided into 4 groups based on eGFR levels (mL/min/1.73 m2): group 1, eGFR ≥ 80(n = 80); group 2, eGFR 60–80 (n = 156); group 3, eGFR 30–60 (n = 114); and group 4 ,eGFR < 30 (n = 15). IVIM imaging was used to acquire diffusion-weighted images at 12 b values. The diffusion coefficient of pure molecular diffusion (D), the diffusion coefficient of microcirculation or perfusion (D*), and perfusion fraction (f) were compared among the groups using group 1 as control.Results
In the renal cortex, D* values were significantly lower in groups 2, 3, and 4 than in group 1. The D value of renal cortex was significantly low in only group 3. In the renal medulla, the D* and D values were significantly lower only in groups 2 and 3, respectively.Conclusion
As renal dysfunction progresses, renal perfusion might be reduced earlier and affected more than molecular diffusion in the renal cortex. These changes are effectively detected by IVIM MR imaging. 相似文献3.
H. Jordan Garber William H. Oldendorf Leon D. Braun Robert B. Lufkin 《Magnetic resonance imaging》1989,7(6):605-610
Following nephrectomy and intravenous injection of tritiated mannitol, adult male rats were exposed to magnetic resonance imaging (MRI) procedures at 1.5 T, 0.5 T, and 0.3 T. Compared to rats similarly handled but not exposed to MRI procedures, brain mannitol concentration, expressed as a percentage of mean body concentration, was significantly increased at 0.3 T and 0.5 T but not at 1.5 T. At 0.3 T, exposure to gradient-field fluctuations used for imaging increased brain mannitol concentration, but exposures to static main field and pulsed radiofrequency energies did not. Increased brain mannitol associated with gradient-field flux may reflect increased blood-brain barrier permeability or blood volume in brain. MRI effects on brain mannitol space are of uncertain clinical significance, but are consistent with prior evidence of an MRI-induced increase of brain capillary endothelial cell transport observed with horseradish peroxidase. Further studies are needed to confirm these findings and to explore the processes underlying changes in mannitol distribution related to MRI. 相似文献
4.
PURPOSE: The aim of this experimental study was to evaluate the potential of a simple expiration technique by means of magnetic resonance imaging (MRI) in an animal model to detect pulmonary air-trapping areas after artificial bronchial obstruction. MATERIAL AND METHODS: Sixteen pigs were evaluated by means of a modified T1-weighted FLASH with fat saturation in respiratory arrest (TR=4.6 ms, TE=1.8 ms, alpha=10 degrees, S.D.=3-5 mm). A measurement of the signal intensity (SI) in the peripheral lung tissue was made in both inspiration and expiration before and after inhalation of 2 ml of 0.5% acetylcholine to simulate a bronchial obstruction. A final measurement of the lung SI was also made after bronchospasmolytic induction through salbutamol (beta2-mimetic bronchodilator). RESULTS: In expiration, a mean SI increase in peripheral lung tissue of about 183% was seen in comparison to inspiration (mean SI increase of 11-32). After inhalation of 0.5% acetylcholine, the expirational signal increase in peripheral lung tissue was only 114% of the original SI. The expirational signal homogeneity decreased after inhalation of acetylcholine. After inhalation of salbutamol, the lung tissue signal elevation in expiration was 193%. CONCLUSION: We interpret the low expiratory signal elevation after acetylcholine inhalation as a result of an air-trapped bronchial constriction in certain areas. The simple expiratory technique in an animal model showed that it is suitable to demonstrate obstructive air trapping using MRI. 相似文献
5.
Objective
Three different kinds of transfection reagents were used to mediate the transfection of gadolinium-diethylenetriamine penta-acetic acid (Gd-DTPA) into human umbilical-cord-derived mesenchymal stem cells (hUCMSCs). The efficacy of different transfection reagents and the feasibility of NMR tracer in vitro of magnetized stem cells were estimated.Methods
After purification by tissue explants adherent method, the biological characteristics of hUCMSCs in vitro were identified by subculture and amplification. Calcium phosphate, Effectene and liposome2000 were used to transfect Gd-DTPA-labeled hUCMSCs respectively, and cell counting was used to mediate the transfection of Gd-DTPA into hUCMSCs, which were then induced to lipoblast and osteoblast in vitro. The determination of the transfection activities of the transfection reagents was conducted by measuring the magnetic resonance imaging (MRI) signal intensity of the Gd-DTPA-labeled cells and the concentration of gadolinium ion in the cells. Furthermore, the relationship between the signal intensity of Gd-DTPA-labeled hUCMSCsMRI, cell subculture and generations was studied.Results
Primary cells were obtained by tissue explants adherent for two weeks. The cells displayed a long spindle form and grew in swirl. After two passage generations, the cellular morphology became more homogeneous. The result detected by the flow cytometer showed that CD29C, D44, CD90, and CD105 were highly expressed, while no CD45, CD40, and HLA-DR expression was detected in the third generation cells. Directional induction in vitro caused the differentiation into lipoblast and osteoblast. After transfected by calcium phosphate, Effectene and liposome 2000, the signal intensity of stem cells was 2281.2 ± 118.8, 2031.9 ± 59.7 and 1887.4 ± 40.8 measured by MRI. Differences between these three groups were statistically significant (P < 0.05). The concentrations of gadolinium ion in three groups of stem cells were 0.178 ± 0.009 mg/L, 0.158 ± 0.003 mg/L and 0.120 ± 0.002 mg/L respectively, examined by inductively coupled plasma atomic emission spectrometry. No significant differences were found among these three groups (P < 0.05). The proliferation and differentiation abilities of the Gd-DTPA-labeled stem cells were not affected. A minimum 5 × 104 Gd-DTPA-labeled stem cells could be traced with MRI in vitro and presented in high signal. The trace duration time in vitro was about 12 days.Conclusions
Tissue explants adherent method can be availably applied to purify hUCMSCs. The Effectene method was proved to have the best transfection effect. The proliferation ability and differentiation potency of Gd-DTPA-labeled hUCMSCs were not affected, and the NMR of labeled stem cells in vitro was proved to be feasible. 相似文献6.
Mikhail Kozlov Robert Turner 《Journal of magnetic resonance (San Diego, Calif. : 1997)》2009,200(1):147-152
To accelerate the analysis of a multi-element MRI coil, a two-way link is used between radiofrequency (RF) circuit and 3-D electromagnetic (EM) simulation tools. In this configuration, only one 3-D EM simulation is required to investigate the coil performance over a range of different tunings, saving considerable computation time. For the purpose of 3-D EM simulation, the coil feed networks and trim capacitors are substituted by 50 Ω ports. The entire coil was tuned in the RF circuit domain, and the near-field profiles of the electric and magnetic field components were then calculated, together with the specific energy absorption ratio (SAR) maps in the 3-D EM domain 相似文献
7.
Purpose
The objective of this paper was to automatically segment the cerebellum from T1-weighted human brain magnetic resonance (MR) images.Materials and Methods
The proposed method constructs a cerebellum template using five sets of 3-T MR imaging (MRI) data, which are used to determine the initial position and the shape prior of the cerebellum for the active contour model. Our formulation includes the active contour model with shape prior, which thereby maintains the shape of the template. The proposed active contour model is sequentially applied to sagittal-, coronal- and transverse-view images. To evaluate the proposed method, it is applied to BrainWeb data and a 3-T MRI data set and compared with FreeSurfer with respect to performance assessment metrics.Results
The segmented cerebellum was compared with the results from FreeSurfer. Using the manually segmented cerebellum as reference, we measured the average Jaccard coefficients of the proposed method, which were 0.882 and 0.885 for the BrainWeb data and 3-T MRI data set, respectively.Conclusion
We presented the active contour model with shape prior for extracting the cerebellum from T1-weighted brain MR images. The proposed method yielded a robust and accurate segmentation result. 相似文献8.
Technical evaluation of in vivo abdominal fat and IMCL quantification using MRI and MRSI at 3 T 总被引:1,自引:0,他引:1
Li X Youngren JF Hyun B Sakkas GK Mulligan K Majumdar S Masharani UB Schambelan M Goldfine ID 《Magnetic resonance imaging》2008,26(2):188-197
OBJECTIVES: The objectives of this study were to develop protocols that measure abdominal fat and calf muscle lipids with magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), respectively, at 3 T and to examine the correlation between these parameters and insulin sensitivity. MATERIALS AND METHODS: Ten nondiabetic subjects [five insulin-sensitive (IS) subjects and five insulin-resistant (IR) subjects] were scanned at 3 T. Visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) were segmented semiautomatically from abdominal imaging. Intramyocellular lipids (IMCL) in calf muscles were quantified with single-voxel MRS in both soleus and tibialis anterior muscles and with magnetic resonance spectroscopic imaging (MRSI). RESULTS: The average coefficient of variation (CV) of VAT/(VAT+SAT) was 5.2%. The interoperator CV was 1.1% and 5.3% for SAT and VAT estimates, respectively. The CV of IMCL was 13.7% in soleus, 11.9% in tibialis anterior and 2.9% with MRSI. IMCL based on MRSI (3.8+/-1.2%) were significantly inversely correlated with glucose disposal rate, as measured by a hyperinsulinemic-euglycemic clamp. VAT volume correlated significantly with IMCL. IMCL based on MRSI for IR subjects was significantly greater than that for IS subjects (4.5+/-0.9% vs. 2.8+/-0.5%, P=.02). CONCLUSION: MRI and MRS techniques provide a robust noninvasive measurement of abdominal fat and muscle IMCL, which are correlated with insulin action in humans. 相似文献
9.
Accurate segmentation of knee cartilage is required to obtain quantitative cartilage measurements, which is crucial for the assessment of knee pathology caused by musculoskeletal diseases or sudden injuries. This paper presents an automatic knee cartilage segmentation technique which exploits a rich set of image features from multi-contrast magnetic resonance (MR) images and the spatial dependencies between neighbouring voxels. The image features and the spatial dependencies are modelled into a support vector machine (SVM)-based association potential and a discriminative random field (DRF)-based interaction potential. Subsequently, both potentials are incorporated into an inference graphical model such that the knee cartilage segmentation is cast into an optimal labelling problem which can be efficiently solved by loopy belief propagation. The effectiveness of the proposed technique is validated on a database of multi-contrast MR images. The experimental results show that using diverse forms of image and anatomical structure information as the features are helpful in improving the segmentation, and the joint SVM-DRF model is superior to the classification models based solely on DRF or SVM in terms of accuracy when the same features are used. The developed segmentation technique achieves good performance compared with gold standard segmentations and obtained higher average DSC values than the state-of-the-art automatic cartilage segmentation studies. 相似文献
10.
Interest in the manner in which brain tissue signal decays with b factor in diffusion imaging schemes has grown in recent years following the observation that the decay curves depart from purely monoexponential decay behavior. Regardless of the model or fitting function proposed for characterizing sufficiently sampled decay curves (vide infra), the departure from monoexponentiality spells increased tissue characterization potential. The degree to which this potential can be harnessed to improve specificity, sensitivity and spatial localization of diseases in brain, and other tissues, largely remains to be explored. Furthermore, the degree to which currently popular diffusion tensor imaging methods, including visually impressive white matter fiber “tractography” results, have almost completely ignored the nonmonoexponential nature of the basic signal decay with b factor is worthy of communal introspection. Here we limit our attention to a review of the basic experimental features associated with brain water signal diffusion decay curves as measured over extended b-factor ranges, the simple few parameter fitting functions that have been proposed to characterize these decays and the more involved models, e.g.,“ruminations,” which have been proposed to account for the nonmonoexponentiality to date. 相似文献
11.
Magnetic resonance imaging (MRI) is a valuable diagnostic tool in medical science due to its capability for soft-tissue characterization and three-dimensional visualization. One potential application of MRI in clinical practice is brain parenchyma classification and segmentation. Based on fuzzy knowledge and modified seeded region growing, this work proposes a novel image segmentation method, called Fuzzy Knowledge-Based Seeded Region Growing (FKSRG), for multispectral MR images. In this work, fuzzy knowledge includes the fuzzy edge, fuzzy similarity and fuzzy distance, which are obtained from relationships between pixels in multispectral MR images and are applied to the modified seeded regions growing process. In conventional regions merging, the final number of regions is unknown. Therefore, a Target Generation Process is proposed and applied to support conventional regions merging, such that the FKSRG method does not over- or undersegment images. Finally, two image sets, namely, computer-generated phantom images and real MR images, are used in experiments to assess the effectiveness of the proposed FKSRG method. Experimental results demonstrate that the FKSRG method segments multispectral MR images much more effectively than the Functional MRI of the Brain Automated Segmentation Tool, K-means and Support Vector Machine methods. 相似文献
12.
Sanchez Lopez H Poole M Crozier S 《Journal of magnetic resonance (San Diego, Calif. : 1997)》2010,207(2):251-261
Eddy currents are inevitably induced when time-varying magnetic field gradients interact with the metallic structures of a magnetic resonance imaging (MRI) scanner. The secondary magnetic field produced by this induced current degrades the spatial and temporal performance of the primary field generated by the gradient coils. Although this undesired effect can be minimized by using actively and/or passively shielded gradient coils and current pre-emphasis techniques, a residual eddy current still remains in the MRI scanner structure. Accurate simulation of these eddy currents is important in the successful design of gradient coils and magnet cryostat vessels. Efficient methods for simulating eddy currents are currently restricted to cylindrical-symmetry. The approach presented in this paper divides thick conducting cylinders into thin layers (thinner than the skin depth) and expresses the current density on each as a Fourier series. The coupling between each mode of the Fourier series with every other is modeled with an inductive network method. In this way, the eddy currents induced in realistic cryostat surfaces by coils of arbitrary geometry can be simulated. The new method was validated by simulating a canonical problem and comparing the results against a commercially available software package. An accurate skin depth of 2.76 mm was calculated in 6 min with the new method. The currents induced by an actively shielded x-gradient coil were simulated assuming a finite length cylindrical cryostat consisting of three different conducting materials. Details of the temporal-spatial induced current diffusion process were simulated through all cryostat layers, which could not be efficiently simulated with any other method. With this data, all quantities that depend on the current density, such as the secondary magnetic field, are simply evaluated. 相似文献
13.
Objective
To evaluate the correlation between findings from diffusion weighted imaging (DWI) and microvascular density (MVD) measurements in VX2 liver tumors after transarterial embolization ablation (TEA).Materials and Methods
Eighteen New Zealand white rabbits were used in this study. VX2 tumor cells were implanted in livers by percutaneous puncture under computed tomography (CT) guidance. Two weeks later, all rabbits underwent conventional magnetic resonance imaging (MRI) (T1 and T2 imaging), DWI, (b = 100, 600, and 1000 s/mm2) and TEA. MRI was performed again1 week after TEA. Liver tissue was then harvested and processed for hematoxylin and eosin (H&E) staining and immunohistochemical staining for CD31to determine MVD.Results
VX2 liver tumors were successfully established in all 18 rabbits. Optimal contrast was achieved with a b value of 600 s/mm2.The maximum pre-operative apparent diffusion coefficient (ADC)difference value was 0.28 × 10− 3 ± 0.10 × 10− 3 mm2/s, and was significantly different (P < 0.001) from the maximum postoperative ADCdifference value of 0.47 × 10− 3 ± 0.10 × 10− 3 mm2/s. However, the mean ADC value for the entire tumor was not significantly correlated with MVD (r = 0.221, P = 0.379), nor was the ADC value for the regions of viable tumor (r = − 0.044, P = 0.862). However, the maximum postoperative ADCdifference value was positively correlated with MVD(r = 0.606, F = 12.247, P = 0.003).Conclusion
DWI is effective to evaluate the therapeutic efficacy of TEA. The maximum ADCdifference offers a promising new method to noninvasively assess tumor angiogenesis. 相似文献14.
Ali-Reza Mohammadi-Nejad Gholam-Ali Hossein-Zadeh Hamid Soltanian-Zadeh 《Magnetic resonance imaging》2010
Super-paramagnetic iron oxide (SPIO) nanoparticles are actively investigated to enhance disease detection through molecular imaging using magnetic resonance imaging (MRI). Detection of the cells labeled by SPIO depends on the MRI protocols and pulse sequence parameters that can be optimized. To evaluate the sensitivity and specificity of the image acquisition methods and to obtain optimal imaging parameters for single-cell detection, we further developed an MRI simulator. The simulator models an object (tissue) at a microscopic level to evaluate effects of spatial distribution and concentration of nanoparticles on the resulting image. In this study, the simulator was used to evaluate and compare imaging of the labeled cells by the gradient-echo (GE), true-FISP [fast imaging employing steady-state acquisition (FIESTA)] and echo-planar imaging (EPI) pulse sequences. Effects of the imaging and object parameters, such as field strength, imaging protocol and pulse sequence parameters, imaging resolution, cell iron load, position of SPIO within the voxel and cell division within the voxel, were investigated in the work. The results suggest that true-FISP has the highest sensitivity for single-cell detection by MRI. 相似文献
15.
OBJECTIVE: The purpose of this study was to evaluate cartilage defect at medial femoral condyle on MRI in early osteoarthritis and to compare with early osteoarthritis with meniscal tear without clear cartilage defect. MATERIALS AND METHODS: Twelve patients with medial pain of the knee and cartilage defect without meniscal tear by MRI were studied for cartilage defect. There were two males and 10 females with cartilage defect, and they were between 42 and 61 years of age (average, 51.6). Fifteen patients with medial pain of the knee and meniscal tear and without clear cartilage defect had been studied as meniscal tear cases. There were five males and 10 females with meniscal tear, and they were between 45 and 61 years of age (average 54.5). In both groups, knee injuries by trauma and Kellgren radiographic grade III and IV osteoarthritis were excluded. We compared cartilage defect cases and meniscal tear cases by gender, age, medial meniscus displacement ratio from the edge of the tibial medial joint surface, femorotibial angle (FTA) and Mikulicz line. We measured medial meniscus displacement ratio by the proportion of medial meniscus lesion protruding from the edge of tibial medial joint surface to all the medial meniscus width on MRI. For the evaluation of Mikulicz line, we measured the score by the length from tibial medial joint surface to Mikulicz line to tibial plateau width. chi(2) Test was used for gender, and Mann-Whitney U test was used for age, medial meniscus displacement ratio, FTA and Mikulicz line. RESULTS: Statistically significant difference was not observed between cartilage defect cases and meniscal tear cases for age and gender. Medial meniscus displacement ratio was 13+/-12.3% in cartilage defect cases and 50.4+/-20.1% in meniscal tear cases. Medial meniscus displacement ratio in cartilage defect cases was significantly smaller than in meniscal tear cases (P=.0001). FTA was 174.9+/-2.2 degrees in cartilage defect cases and 178.3+/-4.8 degrees in meniscal tear cases. FTA in cartilage defect cases was significantly smaller than in meniscal tear cases (P=.00390). The score by the length from tibial medial joint surface to Mikulicz line to tibial plateau width was 35.8+/-11.8% in cartilage defect cases and 21.7+/-15.8% in meniscal tear cases. Mikulicz line in cartilage defect cases passes more laterally than in meniscal tear cases significantly (P=.0264). CONCLUSION: In this study, we reported cartilage defect cases at medial femoral condyle in the early osteoarthritis of the knee. We think that these cases were different from early osteoarthritis with meniscal tear in alignment of lower limb and onset mechanism. It is necessary to evaluate meniscus and cartilage in MRI when we diagnose middle-aged patients with medial pain of the knee and without remarkable changes of X-ray. 相似文献
16.
The advantages of open, vertical-field, magnetic resonance-guided, focused ultrasound surgery (MRgFUS) are attractive. The inverse technique using the bi-boundary conditions is proposed to design a uterine-oriented intraoperative RF coil with an ultrasound aperture for the MRgFUS system. In the current proposed scheme, the desired magnetic field of the RF coil was set to completely overlap the target organ. The current density distribution on the RF coil surface, accounting for the expected magnetic field, was solved using the inverse technique. The stream function was available through the ‘discretization’ of the current density distribution on the RF coil surface. The coil windings were obtained from the contour plot of the stream function. As a modification of previous designs, the bi-boundary conditions are proposed in the inverse technique for the existence of the ultrasound aperture. Based on the obtained coil windings, a prototype coil was constructed. MR imaging of the phantom and the human body was performed to show the efficacy of the prototype coil. The results of temperature measurement using the prototype coil in a 0.4-T MR system were satisfactory. The performance of the prototype coil improved compared with the previously reported design. 相似文献
17.
Krzysztof Jurczuk Marek Kretowski Jean-Jacques Bellanger Pierre-Antoine Eliat Hervé Saint-Jalmes Johanne Bézy-Wendling 《Magnetic resonance imaging》2013
In this work, a computational model of magnetic resonance (MR) flow imaging is proposed. The first model component provides fluid dynamics maps by applying the lattice Boltzmann method. The second one uses the flow maps and couples MR imaging (MRI) modeling with a new magnetization transport algorithm based on the Eulerian coordinate approach. MRI modeling is based on the discrete time solution of the Bloch equation by analytical local magnetization transformations (exponential scaling and rotations). 相似文献
18.
Background and Purpose
Fine-mesh braided, stent-like structures (flow diverters) have been proposed for treatment of brain aneurysms. To date, the safety of performing magnetic resonance imaging (MRI) in patients with these implants is unknown. Therefore, the purpose of this study was to evaluate MRI issues at 3-T for a new flow-diverting implant used to treat brain aneurysms.Methods
The Surpass NeuroEndoGraft (Surpass Medical, Ltd., Tel Aviv, Israel) underwent evaluation for magnetic field interactions, MRI-related heating and artifacts using standardized techniques. Magnetic field interactions were assessed for this implant with regard to translational attraction (i.e., using the deflection angle technique) and torque (qualitative assessment method). MRI-related heating was evaluated by placing the implant in a gelled-saline-filled, head/torso phantom and performing MRI using a transmit/receive radiofrequency body coil at a whole-body-averaged specific absorption rate of 2.9 W/kg for 15 min. Artifacts were characterized using T1-weighted, spin echo (SE) and gradient echo (GRE) pulse sequences.Results
The Surpass NeuroEndoGraft exhibited minor magnetic field interactions (21° deflection angle and no torque), which were acceptable from a safety consideration. Heating was not substantial, with the highest temperature change being 2.3°C (background temperature rise without the implant was 1.5°C). Artifacts may create issues if the area of interest is in the same area or close to this implant.Conclusions
The findings demonstrated that it would be acceptable for patients with this next-generation, flow-diverting implant to undergo MRI at 3-T or less. 相似文献19.
Purpose
The purpose was to investigate the altered hemispheric asymmetry in patients with mesial temporal lobe epilepsy with unilateral hippocampus sclerosis (MTLE/HS).Materials and methods
This study examined the hemispheric asymmetry of regional gray matter (GM) and white matter (WM) volume among a group of 13 patients with left-sided MTLE/HS, a group of 10 patients with right-sided MTLE/HS and a group of 21 age- and gender- matched healthy controls by optimized voxel-based morphometry (VBM) based on magnetic resonance imaging.Results
Compared to healthy controls, abnormal asymmetries were detected in the left-sided MTLE/HS patients. The left-sided MTLE/HS patients had more GM asymmetries (L<R) in the temporal lobes, including the inferior temporal gyrus, middle temporal gyrus and parahippocampal gyrus. There was significant asymmetry (L<R) in subcortical WM of the mesial temporal lobe in left-sided MTLE/HS patients. However, no significant difference was detected in terms of GM and WM asymmetry between the group with right-sided MTLE/HS and normal controls.Conclusion
We should approach hemispheric asymmetry in left- and right-sided MTLE/HS patients differently. The study also demonstrates potential future use of VBM in detecting hemispheric asymmetries and lateralization of brain functions. 相似文献20.
Sharma U Sah RG Parshad R Sharma R Seenu V Jagannathan NR 《Magnetic resonance imaging》2012,30(5):649-655
We carried out retrospective analysis of apparent diffusion coefficient (ADC) values in 48 infiltrating ductal breast cancer patients who had dynamic contrast-enhanced magnetic resonance imaging (DCEMRI; Group I) and in 53 patients (Group II) for whom DCEMRI data were not available. Twenty-three patients of Group I showed no necrosis (Group Ia), while in 25 patients, both viable (nonnecrotic) and necrotic tumor areas (Group Ib) were observed on DCEMRI. T1-weighted, fat-suppressed and short inversion recovery images were used to identify the viable and necrotic tumor areas in Group II patients, and necrosis was not seen in 11 patients (Group IIa), while 42 (Group IIb) showed both viable and necrotic tumor areas. The ADCs of the necrotic area of Group Ib (1.79±0.30 ×10(-3) mm(2)/s) and Group IIb (1.83±0.40 ×10(-3) mm(2)/s) patients were similar and significantly higher (P<.01) compared to the ADCs of the viable tumor area of Group Ia (0.96±0.21 ×10(-3) mm(2)/s) and Group IIa (0.90±0.17 ×10(-3) mm(2)/s) patients. Proton MR spectroscopy (MRS) data were also available in these patients, and the ADC values were retrospectively determined from the voxel from which MR spectrum was obtained. These values were compared with the ADC obtained for the viable and necrotic areas of the tumor. ADC of the MRS voxel was similar to that obtained for the viable tumor area in patients of both groups. This interesting observation reveals the potential utility of using ADC values to identify viable tumor area for positioning of voxel for MRS in the absence of DCEMRI data. 相似文献