共查询到5条相似文献,搜索用时 0 毫秒
1.
Christina L. Sammet Xiangyu Yang Peter A. Wassenaar Eric C. Bourekas Brian A. Yuh Frank Shellock Steffen Sammet Michael V. Knopp 《Magnetic resonance imaging》2013
Purpose
The purpose was to evaluate radiofrequency (RF)-related heating of commonly used extracranial neurosurgical implants in 7-T magnetic resonance imaging (MRI).Materials and methods
Experiments were performed using a 7-T MR system equipped with a transmit/receive RF head coil. Four commonly used titanium neurosurgical implants were studied using a test procedure adapted from the American Society for Testing and Materials Standard F2182-11a. Implants (n = 4) were tested with an MRI turbo spin echo pulse sequence designed to achieve maximum RF exposure [specific absorption rate (SAR) level = 9.9 W/kg], which was further validated by performing calorimetry. Maximum temperature increases near each implant's surface were measured using fiberoptic temperature probes in a gelled-saline-filled phantom that mimicked the conductive properties of soft tissue. Measurement results were compared to literature data for patient safety.Results
The highest achievable phantom averaged SAR was determined by calorimetry to be 2.0 ± 0.1 W/kg due to the highly conservative SAR estimation model used by this 7-T MR system. The maximum temperature increase at this SAR level was below 1.0 °C for all extracranial neurosurgical implants that underwent testing.Conclusion
The findings indicated that RF-related heating under the conditions used in this investigation is not a significant safety concern for patients with the particular extracranial neurosurgical implants evaluated in this study. 相似文献2.
Ultra-high-field clinical MRI scanners (e.g., 7 T and above) are becoming increasingly prevalent and can potentially enhance diagnostic ability through higher contrast, resolution and/or sensitivity. Diffusion-weighted MRI is a highly valued component in today's radiological exam and may benefit from the enhanced signal-to-noise ratio provided by high field with the appropriate imaging strategy. The most common diffusion pulse sequence readout (echo-planar imaging (EPI)) has been widely employed for in vivo human 7 T diffusion tensor imaging (DTI). In this article, we present results of brain DTI at 7 T with two diffusion-weighted imaging pulse sequence readouts: echo-planar imaging (EPI-DTI) and turbo spin echo (TSE-DTI). Results indicate that analogous coverage, quality and resolution typical of lower field (2 mm) can be obtained by properly processed EPI-DTI at 7 T, and, with some reduction in efficiency and sharpness, TSE-DTI at 7 T. Furthermore, 7 T TSE-DTI shows promise in obtaining higher-resolution results in targeted acquisitions of specific brain areas. 相似文献
3.
Purpose
To determine the feasibility of using R2? map MRI for pretreatment diagnosis and monitoring of tumor response to neoadjuvant chemotherapy (NAC) in patients with breast cancer.Material and Methods
Twenty-eight women with breast cancer, as evidenced by pathology, underwent MR imaging prior to and after chemotherapy. All patients were examined by conventional MRI and R2? map imaging. Subjects were divided into major histological response (MHR) and non-major histological response (NMHR) groups. Mean R2? values of cancerous and normal glandular tissues were measured before and following NAC. Differences in R2? and ΔR2?% values between these two groups were compared with paired or independent t tests. The relationship between ΔR2?% and histological response was examined using Spearman's correlation test.Results
Before NAC, the average R2? values in carcinoma were lower than in normal glandular tissue (P<.05). After two to four cycles of NAC, the R2? values in carcinoma were increased (P<.05 ), but this change was not significant in normal glandular tissue. After NAC, ΔR2?% was significantly higher in MHR as compared to NMHR (P<.05). The ΔR2?% correlated with the histological response (r=0.581, P<.01).Conclusion
In women undergoing NAC for breast cancer treatment, R2? and ΔR2?% appear to provide predictive information of tumor response which is probably associated with changes in tumor angiogenesis and tissue oxygenation. R2? map imaging of breasts may therefore be useful in monitoring tumor response to NAC. 相似文献4.
Glycosaminoglycan Chemical Exchange Saturation Transfer (gagCEST) is an important molecular MRI methodology developed to assess changes in cartilage GAG concentrations. The correction for B0 field inhomogeneity is technically crucial in gagCEST imaging. This study evaluates the accuracy of the B0 estimation determined by the dual gradient echo method and the effect on gagCEST measurements. The results were compared with those from the commonly used z-spectrum method. Eleven knee patients and three healthy volunteers were scanned. Dual gradient echo B0 maps with different ?TE values (1, 2, 4, 8, and 10 ms) were acquired. The asymmetry of the magnetization transfer ratio at 1 ppm offset referred to the bulk water frequency, MTRasym(1 ppm), was used to quantify cartilage GAG levels. The B0 shifts for all knee patients using the z-spectrum and dual gradient echo methods are strongly correlated for all ?TE values used (r = 0.997 to 0.786, corresponding to ?TE = 10 to 1 ms). The corrected MTRasym(1 ppm) values using the z-spectrum method (1.34% ± 0.74%) highly agree only with those using the dual gradient echo methods with ?TE = 10 ms (1.72% ± 0.80%; r = 0.924) and 8 ms (1.50% ± 0.82%; r = 0.712). The dual gradient echo method with longer ?TE values (more than 8 ms) has an excellent correlation with the z-spectrum method for gagCEST imaging at 3 T. 相似文献
5.
Iron Oxide Nanoparticles: Facile Synthesis of Gd(OH)3‐Doped Fe3O4 Nanoparticles for Dual‐Mode T1‐ and T2‐Weighted Magnetic Resonance Imaging Applications (Part. Part. Syst. Charact. 10/2015) 下载免费PDF全文
Hongdong Cai Xiao An Shihui Wen Jingchao Li Guixiang Zhang Xiangyang Shi Mingwu Shen 《Particle & Particle Systems Characterization》2015,32(10):918-918