共查询到20条相似文献,搜索用时 27 毫秒
1.
Yang Shin Park Chang Hee Lee Ji Hoon Kim In Seong Kim Berthold Kiefer Tae Seok Seo Kyeong Ah Kim Cheol Min Park 《Magnetic resonance imaging》2014
Purpose
To assess the usefulness of intravoxel incoherent motion diffusion weighted imaging (IVIM-DWI) for predicting lipiodol uptake in patients with hepatocellular carcinoma (HCC) after transcatheter arterial chemoembolization (TACE).Materials and methods
The institutional review board approved this study. 44 HCC patients underwent IVIM-DWI and Gd-EOB-DTPA-enhanced MRI prior to TACE. Using post-TACE CT as a reference standard, each HCC was classified into either lipiodol good uptake (LGU) or poor uptake (LPU) group. Apparent diffusion coefficient (ADC), true diffusion coefficient (D), perfusion coefficient (D*), and perfusion fraction (f) in HCC were calculated. Arterial enhancement ratio (AER) and IVIM parameters were compared between those two groups using the Mann-Whitney U test.Results
Of the 51 HCCs, 37 (72.5%) were LGU group and 14 (27.5%) were LPU group. AER of HCC was significantly higher in LGU than LPU (0.99 ± 0.54 and 0.67 ± 0.45; P = .034). ADC, D, and f values were not significantly different (P = .073, .059, and .196, respectively) between these two groups. D* was significantly elevated in LGU than LPU (48.10 ± 15.33 and 26.75 ± 9.55; P = .001).Conclusion
Both AER derived from contrast enhanced MRI and D* values derived from IVIM-DWI for HCC were significantly higher in LGU than in LPU. These parameters would be helpful for predicting the lipiodol uptake. 相似文献2.
Le Moigne F Durieux M Bancel B Boublay N Boussel L Ducerf C Berthezène Y Rode A 《Magnetic resonance imaging》2012,30(5):656-665
Purpose
The purpose of this study was to determine whether or not adding diffusion-weighted magnetic resonance imaging (DWI) to conventional magnetic resonance (MR) imaging sequences improves the characterization of small hepatocellular carcinoma (HCC) (≤2 cm) in the setting of cirrhotic liver compared to conventional sequences alone.Materials and Methods
A total of 62 cirrhotic liver patients with 82 nodules smaller than 2 cm in diameter were enrolled, and all lesions were pathologically confirmed. For the first reading session, which included precontrast T1- and T2-weighted images and T1 dynamic contrast-enhanced images, preindicated lesions by a study coordinator were characterized by two radiologists. They determined the confidence levels in consensus for the presence of small HCC into four grades. In another session, respiratory-triggered diffusion-weighted MR images (b factor=50, 400 and 800 s/mm2) were added to the previously reviewed images, and the same two radiologists again determined the confidence levels. The diagnostic performance of the combined DWI–conventional sequences set and the conventional sequences alone set was evaluated using receiver operating characteristic curves. Sensitivity and specificity values for characterizing small HCCs were also calculated.Results
The area under the receiver operating characteristic curve for the second interpretation session (0.86) was significantly higher (P=.038) than that of the first session (0.76). The sensitivity was significantly increased from 75.7% to 87.8% by adding DWI to the conventional sequences (P=.015). No significant differences were observed for specificity values.Conclusion
Adding DWI to conventional imaging modalities improves the diagnosis of small HCCs in the cirrhotic liver in terms of diagnostic performance and sensitivity by increasing reader confidence. 相似文献3.
Shimizu A Ito K Sasaki K Hayashida M Tanabe M Shimizu K Matsunaga N 《Magnetic resonance imaging》2007,25(10):1430-1436
PURPOSE: The aim of this study was to evaluate the frequency and magnetic resonance imaging (MRI) features of clinically benign, small (<2 cm) hyperintense hepatic lesions in the cirrhotic liver on T1-weighted MR images seen at serial MRI. MATERIALS AND METHODS: This study included 189 patients with cirrhosis, who underwent hepatic MRI more than twice with an interval of at least 12 months. The initial MR images were reviewed for the presence of small hyperintense lesions on T1-weighted images. The size, location and signal intensity on T2-weighted images as well as enhancement patterns of the corresponding lesions were recorded. RESULTS: On the initial T1-weighted MR images, 43 small hyperintense hepatic lesions were detected in 23 (12%) of 189 patients. Twelve (28%) of 43 lesions showed early enhancement and were pathologically diagnosed as hepatocellular carcinoma (HCC) during the follow-up period. Thirty-one (72%) of 43 lesions showed no early enhancement with various signal intensity on T2-weighted images (hyperintensity=4, isointensity=20, hypointensity=7). Among these 31 lesions, 12 showed no interval change, while 11 disappeared (n=10) or decreased in size (n=1). In the remaining eight lesions, seven were diagnosed as HCC on the basis of pathologic confirmation or the interval growth. CONCLUSION: Small hyperintense hepatic lesions on T1-weighted magnetic resonance (MR) images without early enhancement on the arterial-phase contrast-enhanced dynamic studies in patients with cirrhosis usually showed no interval growth or disappeared during the serial MRI. These lesions with additional findings of iso- or hypointensity on the T2-weighted MR images without "washout effect" on the contrast-enhanced equilibrium-phase images may more frequently be clinically benign or hyperplastic nodules than HCCs. 相似文献
4.
Prostate cancer detection using diffusion-weighted imaging is highly affected by the accuracy of the apparent diffusion coefficient (ADC) values in an image. Echo planar imaging (EPI) is a fast sequence commonly used for diffusion imaging but has inherent magnetic susceptibility and chemical shift artefacts associated. A diffusion sequence that is less affected by these artefacts is therefore advantageous. The half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence was chosen. The diffusion sequences were compared in image quality, repeatability of the ADC value and the effect on the ADC value with varied b values. Eight volunteers underwent three scans of each sequence, on a 1.5-T Siemens system, using b values of 0, 150, 300, 450, 600, 750, 900 and 1000 s/mm(2). ADC maps were created to address the reproducibility of the ADC value when using two b values compared to eight b values. The ADC value using all b values with the HASTE sequence gave the best performance in all tested categories. Both sequences gave significantly different ADC mean values for two b values compared to when using eight b values (P<.05) suggesting larger error is present when using two b values. HASTE was shown to be an improvement over EPI in terms of repeatability, signal variation within a region of interest and standard deviation over the volunteer set. The improved accuracy of the ADC value in the HASTE sequence makes it potentially a more sensitive tumor detection technique. 相似文献
5.
Relaxivities of human liver and spleen ferritin 总被引:1,自引:0,他引:1
Ferritin, the iron-storing protein of mammals, is known to darken T2-weighted magnetic resonance images. This darkening can be used to noninvasively measure an organ's iron content. Significant discrepancies exist between T2 data obtained with ferritin-containing tissues and with aqueous solutions of horse spleen ferritin (HSF). The NMR properties of stable human ferritin have never been studied in aqueous solutions. Relaxometry results on human liver and spleen ferritin are reported here, showing that the relaxation induced in aqueous solutions by human ferritins is comparable to that induced by HSF. As a consequence, the differences between ferritin-containing human tissues and ferritin solutions cannot be attributed to different NMR properties of human and horse ferritins, but probably to a clustering of the protein in vivo. 相似文献
6.
Fasano F Capuani S Hagberg GE Branca T Indovina I Castriota-Scanderbeg A Maraviglia B 《Magnetic resonance imaging》2003,21(10):1151-1157
To study the sensitivity of intermolecular double quantum coherences (iDQc) imaging contrast to brain microstructure and brain anisotropy, we investigated the iDQC contrast between differently structured areas of the brain according to the strength and the direction of the applied correlation gradient. Thus diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI) maps have been obtained. This procedure, which consists of analyzing both iDQc and DWI images at different gradient strength and gradient direction, could be a promising tool for clinical brain investigations performed with higher than 1.5 T magnetic fields. 相似文献
7.
Partridge SC Singer L Sun R Wilmes LJ Klifa CS Lehman CD Hylton NM 《Magnetic resonance imaging》2011,29(9):1215-1221
Promising recent investigations have shown that breast malignancies exhibit restricted diffusion on diffusion-weighted imaging (DWI) and may be distinguished from normal tissue and benign lesions in the breast based on differences in apparent diffusion coefficient (ADC) values. In this study, we assessed the influence of intravoxel fat signal on breast diffusion measures by comparing ADC values obtained using a diffusion-weighted single shot fast spin-echo sequence with and without fat suppression. The influence of breast density on ADC measures was also evaluated. ADC values were calculated for both tumor and normal fibroglandular tissue in a group of 21 women with diagnosed breast cancer. There were systematic underestimations of ADC for both tumor and normal breast tissue due to intravoxel contribution from fat signal on non–fat-suppressed DWI. This ADC underestimation was more pronounced for normal tissue values (mean difference=40%) than for tumors (mean difference=27%, P<.001) and was worse in women with low breast tissue density vs. those with extremely dense breasts (P<.05 for both tumor and normal tissue). Tumor conspicuity measured by contrast-to-noise ratio was significantly higher on ADC maps created with fat suppression and was not significantly associated with breast density. In summary, robust fat suppression is important for accurate breast ADC measures and optimal lesion conspicuity on DWI. 相似文献
8.
Jonathan Israel Evan Unger Kenneth Buetow Truman Brown Baruch Blumberg W.Thomas London 《Magnetic resonance imaging》1989,7(6):629-634
Currently, serum ferritin concentration is the best noninvasive estimator of liver iron content. This study investigated the ability of magnetic resonance imaging to determine hepatic iron concentration. Fisher rats were treated with either parenteral iron to increase levels or phlebotomy to lower them and achieved a wide range of liver iron concentrations. Rats were imaged using a clinical whole body scanner at 1.5 Tesla with a 15-cm Helmholtz surface coil and a 23-cm field of view. The ratio of signal intensity of liver to skeletal muscle from images of the live intact rats correlated well with chemically measured iron concentration of the liver (r = −.89, p < .0001, linear regression analysis). Transverse relaxation rates (1/calculated T2 relaxation times) also correlated with liver iron content (r = .66, p < .0001). The observation of a significant correlation between liver iron content and both signal intensities and T2 relaxation rates, obtained by magnetic resonance imaging, may have considerable clinical relevance. If adapted to humans, this technique would have obvious applications in the diagnosis and management of diseases associated with iron overload as well as in the investigation of the overall role of iron in various human liver diseases. 相似文献
9.
Objective
To evaluate the correlation between findings from diffusion weighted imaging (DWI) and microvascular density (MVD) measurements in VX2 liver tumors after transarterial embolization ablation (TEA).Materials and Methods
Eighteen New Zealand white rabbits were used in this study. VX2 tumor cells were implanted in livers by percutaneous puncture under computed tomography (CT) guidance. Two weeks later, all rabbits underwent conventional magnetic resonance imaging (MRI) (T1 and T2 imaging), DWI, (b = 100, 600, and 1000 s/mm2) and TEA. MRI was performed again1 week after TEA. Liver tissue was then harvested and processed for hematoxylin and eosin (H&E) staining and immunohistochemical staining for CD31to determine MVD.Results
VX2 liver tumors were successfully established in all 18 rabbits. Optimal contrast was achieved with a b value of 600 s/mm2.The maximum pre-operative apparent diffusion coefficient (ADC)difference value was 0.28 × 10− 3 ± 0.10 × 10− 3 mm2/s, and was significantly different (P < 0.001) from the maximum postoperative ADCdifference value of 0.47 × 10− 3 ± 0.10 × 10− 3 mm2/s. However, the mean ADC value for the entire tumor was not significantly correlated with MVD (r = 0.221, P = 0.379), nor was the ADC value for the regions of viable tumor (r = − 0.044, P = 0.862). However, the maximum postoperative ADCdifference value was positively correlated with MVD(r = 0.606, F = 12.247, P = 0.003).Conclusion
DWI is effective to evaluate the therapeutic efficacy of TEA. The maximum ADCdifference offers a promising new method to noninvasively assess tumor angiogenesis. 相似文献10.
YunBin Chen Xiangyi Liu Dechun Zheng Luying Xu Liang Hong Yun Xu Jianji Pan 《Magnetic resonance imaging》2014
Purpose
To prospectively evaluate the feasibility of diffusion-weighted magnetic resonance imaging (DWI) for monitoring early treatment response to chemoradiotherapy (CRT) of nasopharyngeal carcinoma (NPC).Materials and methods
Thirty-one patients with stage III and IV NPC were enrolled in this study from February 2012 to November 2012.T2-weighted and DWI sequences with diffusion factor of 0 and 800mm²/s were performed using a 3.0 T Philips Achieva TX scanner at baseline and 3 days, 20 days (after the first cycle of chemotherapy), 50 days (6 days after radiotherapy initiation) after neoadjuvant chemotherapy (NAC) initiation. The diameter of each primary lesion and target metastatic lymph node before and after the first cycle of NAC was measured and classified into stable disease (SD), partial response (PR) or completed response (CR) based on RECIST 1.1. The apparent diffusion coefficient (ADC) values and changes compared to baseline at each time point were compared between responders (CR and PR) and non-responders (SD). The rates of residual at the end of CRT were compared between these two groups.Results
A significant increase in ADC was observed at each stage of therapy (P=.001) in lesions of primary and metastatic. The ADC values (ADC), ADC changes (ΔADC) and percentage ADC changes (Δ%ADC) of day 20 in responders were significantly higher than in non-responders for both primary lesions (p=.005, p=.006, p=.008, respectively) and metastatic lymph nodes (p=.002, p=.002, p=.003). Non-responders showed a higher rate of residual for both primary lesions (p=.008) and metastatic lymph nodes (p=.024) than responders.Conclusions
DW MR imaging allows for detecting early treatment response of NPC. Patients with high ADC values and large ADC increase early after NAC initiation tended to respond better to CRT. Thus, accessing the curative effect of NAC in advanced NPC provides the opportunity to adjust following CRT regimen. 相似文献11.
Ana Ferreira Miguel Ramalho Rafael O.P. de Campos Vasco Heredia Andreia Roque Georgeta Vaidean Richard C. Semelka 《Magnetic resonance imaging》2013
Purpose
To describe the MR appearances of hepatic sarcoidosis in patients with chronic liver disease and correlate the results with clinical stage of disease as measured with the Mayo end-stage liver disease (MELD) score.Materials and methods
Twenty patients with chronic liver disease and histopathological diagnosis of hepatic sarcoidosis who underwent MR imaging were included in this study. Two abdominal radiologists retrospectively reviewed all images for the presence of cirrhosis, imaging pattern of the liver, intrahepatic biliary dilatation, presence of areas of parenchymal atrophy, presence of splenic nodules and lymphadenopathy. Imaging findings were correlated with the MELD score.Results
Of the patients, 14/20 had imaging findings of cirrhosis, 9/20 had a large macronodular pattern of liver cirrhosis and 5/20 had a diffuse pattern of liver cirrhosis. Peripheral wedge-shaped areas of parenchymal atrophy were observed in 10 patients. The combination of a central macronodular pattern and peripheral atrophy was observed in 9/20 patients. The pattern of cirrhosis had statistically significant correlation with the presence of wedge-shaped areas of parenchymal atrophy (p < 0.005). No statistically significant difference was revealed between the clinical score of patients who had imaging findings consistent with cirrhosis and those who did not.Conclusion
MR imaging appearances of chronic sarcoid liver disease are diverse and do not appear to correlate with severity of clinical disease. Large central regenerative nodules and wedge-shaped areas of peripheral parenchymal atrophy are frequent findings and may help to suggest the diagnosis. 相似文献12.
Kim H Yu JS Cho ES Chung JJ Kim JH Kim DJ Ahn JH Kim KW 《Magnetic resonance imaging》2012,30(4):554-561
Purpose
The purpose was to validate diffusion-weighted imaging (DWI) in the assessment of hepatic metastases compared with superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance imaging.Materials and Methods
For 21 consecutive patients with 160 metastases from extrahepatic malignancy and 25 benign focal lesions, two radiologists evaluated four separate review sessions (I, SPIO-enhanced T2?-weighted images; II, precontrast DWI; III, SPIO-enhanced T2?-weighted images and precontrast DWI; IV, SPIO-enhanced T2?-weighted images plus precontrast and SPIO-enhanced DWI) and assigned confidence levels using a five-grade scale for each hepatic lesion.Results
The Az values after receiver operating characteristic curve analysis for Reader 1 and Reader 2 were 0.80 and 0.75 on session I, 0.91 and 0.91 on session II, 0.97 and 0.96 on session III and 0.96 and 0.96 on session IV, respectively. The Az value of session II was significantly higher than that of session I (Reader 1, P=.004; Reader 2, P<.001), and that of session III was significantly higher than that of session I (P<.001 for each reader) or session II (Reader 1, P=.004; Reader 2, P=.003). Although there was no significant difference of Az value between session III and session IV (Reader 1, P=.231; Reader 2, P=.878), the sensitivity improved for session IV compared with that for session III (Reader 1, P=.031; Reader 2, P=.039).Conclusion
In the assessment of hepatic metastases, DWI can provide more accurate information than can SPIO-enhanced images. Diagnostic accuracy can be increased even more through the combination of both techniques. 相似文献13.
Satoshi Goshima Masayuki Kanematsu Hiroshi Kondo Yusuke Tsuge Haruo Watanabe Yoshimune Shiratori Minoru Onozuka Noriyuki Moriyama 《Magnetic resonance imaging》2009,27(9):1230-1235
The purpose of this study was to compare observer interpreted steady-state coherent coronal images and gadolinium-enhanced axial images in terms of the detection and grading of esophageal varices. Magnetic resonance imaging (MRI) and gastrointestinal endoscopy were performed within 2 weeks in 90 patients with chronic liver damage, including 55 with untreated esophageal varices, for periodic screening purposes. Two blinded readers retrospectively reviewed T1- and T2-weighted images with gadolinium-enhanced (gadolinium image set) and steady-state coherent (coherent image set) images. Sensitivity for the detection of esophageal varices was higher (P<.001) in the gadolinium image set (76%) than in the coherent image set (35%); on the other hand, specificity was higher (P<.001) in the coherent image set (91%) than in the gadolinium image set (66%). Furthermore, area under the ROC curve was higher for the gadolinium image set (Az=0.823) than the coherent image set (Az=0.761) (P=.48). Moderate and weak positive correlations with endoscopic grades were found for the gadolinium image (r=0.48, P<.01) and coherent image sets (r=0.34, P=.018). The addition of steady-state coherent imaging to the current routine liver imaging protocol did not improve the detection or grading of esophageal varices, whereas gadolinium-enhanced imaging was found to be potentially valuable. Nevertheless, endoscopy was confirmed to be mandatory in patients with esophageal varices suspected by MRI of the liver. 相似文献
14.
Shintaro Ichikawa Utaroh MotosugiTomoaki Ichikawa Katsuhiro SanoHiroyuki Morisaka Tsutomu Araki 《Magnetic resonance imaging》2013
Purpose
To investigate the relationship between estimated glomerular filtration rate (eGFR) and parameters calculated using intravoxel incoherent motion (IVIM) imaging of the kidneys.Materials and Methods
We studied 365 patients, divided into 4 groups based on eGFR levels (mL/min/1.73 m2): group 1, eGFR ≥ 80(n = 80); group 2, eGFR 60–80 (n = 156); group 3, eGFR 30–60 (n = 114); and group 4 ,eGFR < 30 (n = 15). IVIM imaging was used to acquire diffusion-weighted images at 12 b values. The diffusion coefficient of pure molecular diffusion (D), the diffusion coefficient of microcirculation or perfusion (D*), and perfusion fraction (f) were compared among the groups using group 1 as control.Results
In the renal cortex, D* values were significantly lower in groups 2, 3, and 4 than in group 1. The D value of renal cortex was significantly low in only group 3. In the renal medulla, the D* and D values were significantly lower only in groups 2 and 3, respectively.Conclusion
As renal dysfunction progresses, renal perfusion might be reduced earlier and affected more than molecular diffusion in the renal cortex. These changes are effectively detected by IVIM MR imaging. 相似文献15.
Tae Hee Kim Jai Keun Kim Wooyoung Shim Sun Yong Kim Tae Jun Park Jae Yeon Jung 《Magnetic resonance imaging》2010
In vivo visualization of transplanted stem cells with noninvasive technique is essential for the monitoring of cell implantation, homing and differentiation. At present, superparamagnetic iron oxide (SPIO) is most commonly used for cell labeling. However, stem cells lack phagocytic capacity and transfection agent is required for sufficient internalization of SPIO for cellular imaging. However, the potential hazards of transfection agents are not fully investigated. Instead of SPIO, we used commercially available new tagging material, fluorescent magnetic nanoparticle (MNP) containing rhodamine B isothiocyanate within a silica shell (Biterials, Seoul, Korea). This tagging material does not require transfection agents for the cell labeling. In addition to that, the core of this MNP is composed of ferrite and the inner portion of silica shell contains fluorescent materials, therefore, it has both magnetic and optical features. This study was designed to track intrasplenically injected bone marrow mesenchymal stem cells (MSCs) labeled with fluorescent MNP in liver cirrhosis rat model with 3-T magnetic resonance equipment. We compared magnetic resonance imaging (MRI) of livers in rats which were injected with non-labeled stem cells or labeled stem cells with MNP or SPIO. We found that the respective liver-to-muscle contrast-to-noise ratios at 3 and 5 h after MNP or SPIO-labeled stem cell injection was significantly lower than that of pre-injection and non-labeled group. There was no significant difference between MNP-labeled group and SPIO-labeled group. We can effectively detect intrasplenically injected MNP-labeled MSCs in an experimental rat model of liver cirrhosis with 3-T MRI. 相似文献
16.
Purpose
To evaluate the liver-to-muscle signal intensity and R2* methods to gain a transferable, clinical application for liver iron measurement.Materials and Methods
Sixteen liver phantoms and 33 human subjects were examined using three 1.5-T MRI scanners from two different vendors. Phantom-to-muscle and liver-to-muscle signal intensity ratios were analyzed to determine MRI estimated phantom and hepatic iron concentration (M-PIC and M-HIC, respectively). R2* was calculated for the phantoms and the liver of human subjects. Seven patients' biochemical hepatic iron concentration was obtained.Results
M-PIC and R2* results of three scanners correlated linearly to phantom iron concentrations (r=0.984 to 0.989 and r=0.972 to 0.981, respectively), and no significant difference between the scanners was found (P=.482 and P=.846, respectively) in vitro. The patients' R2* correlated linearly to M-HIC of the standard scanner (r=0.981). M-HIC values did not differ from those obtained from the biopsy specimens (P=.230). The difference in M-HIC was significant, but the difference in R2* was not significant between the scanners (P<.0001 and P=.505, respectively) in vivo.Conclusion
Both methods, M-HIC and R2*, are reliable iron concentration indicators with linear dependence on iron concentration in vivo and in vitro. The R2* method was found to be comparable among different scanners. Transferability testing is needed for the use of the methods at various scanners. 相似文献17.
18.
Yang Shin Park Chang Hee Lee Baek Hui Kim Jongmee Lee Jae Woong Choi Kyeong Ah Kim Jeong Hwan Ahn Cheol Min Park 《Magnetic resonance imaging》2013
Purpose
The purpose of the study was to determine significant imaging features to differentiate between infiltrative hepatocellular carcinoma (HCC) and confluent fibrosis (CF) in liver cirrhosis using Gd-EOB-DTPA-enhanced 3-T magnetic resonance imaging.Material and methods
Nineteen infiltrative HCCs and eight CFs were included. We evaluated the difference in imaging findings and apparent diffusion coefficient (ADC) between the two entities. We compared T2-weighted image (WI) and hepatobiliary phase (HBP) in terms of the clarity of the lesion outer margin.Results
Seventeen infiltrative HCCs showed lobulated margin, while focal CFs showed either straight (n = 3) or irregular margins (n = 5) (P = .001). All infiltrative HCCs had intact or bulging contours, and all focal CFs showed capsular retraction (P = .001). Fourteen infiltrative HCCs and two focal CFs showed arterial enhancement (P = .035). The ADC of infiltrative HCCs was significantly lower than that of CFs (P = .001). Satellite nodules were noted in 10 infiltrative HCCs. In terms of outer margin clarity, infiltrative HCCs showed a more distinct margin on HBP than on T2-WI (P = .005), while these two sequences were not significantly different in focal CFs (P = 1.000).Conclusion
HBP improved the imaging characteristics of infiltrative HCC, allowing it to be distinguished from focal CF. Infiltrative HCC showed lower ADC values than focal CF. Lobular configuration, contour bulging, enhancement pattern, associated satellite nodules and portal vein thrombosis were still found to be highly suggestive MR findings for infiltrative HCC. 相似文献19.
C. Thomsen P. Wiggers H. Ring-Larsen E. Christiansen J. Dalh j O. Henriksen P. Christoffersen 《Magnetic resonance imaging》1992,10(6):867-879
A total of 4302 healthy blood donors were screened for elevated serum ferritin and transferrin saturation. Fifteen had increased serum ferritin at a follow-up examination. Five relatives of these donors also entered the study. Eleven patients had elevated liver iron concentrations, while five had normal liver iron concentrations. The R2 relaxation rate in the liver was first measured with a conventional multi-spin-echo imaging sequence, and then by a volume-selective spectroscopic multi-spin-echo sequence, in order to achieve a minimum echo time of 4 msec. No correlation was found between the relaxation rate R2 and the liver iron concentration, when R2 was calculated from the imaging data. Multi-exponential transverse relaxation could be resolved when the spectroscopic sequence was used. A strong correlation between the initial slope of the relaxation curve and the liver iron concentration was found (r = 0.90, p < 0.001). Signal intensity ratios between liver and muscle were calculated from the first three echoes in the multi-echo imaging sequence, and from a gradient echo sequence. A strong correlation between the logarithm of the signal intensity ratios and the liver iron concentration was found. Although both spectroscopic T2 relaxation time measurements and signal intensity ratios could be used to quantify liver iron concentration, the gradient echo imaging seemed to be the best choice. Gradient echo imaging could be performed during a single breath hold, so motion artifacts could be avoided. The accuracy of liver iron concentration estimates from signal intensity ratios in the gradient echo images was about 35%. 相似文献
20.
Ultra-high-field clinical MRI scanners (e.g., 7 T and above) are becoming increasingly prevalent and can potentially enhance diagnostic ability through higher contrast, resolution and/or sensitivity. Diffusion-weighted MRI is a highly valued component in today's radiological exam and may benefit from the enhanced signal-to-noise ratio provided by high field with the appropriate imaging strategy. The most common diffusion pulse sequence readout (echo-planar imaging (EPI)) has been widely employed for in vivo human 7 T diffusion tensor imaging (DTI). In this article, we present results of brain DTI at 7 T with two diffusion-weighted imaging pulse sequence readouts: echo-planar imaging (EPI-DTI) and turbo spin echo (TSE-DTI). Results indicate that analogous coverage, quality and resolution typical of lower field (2 mm) can be obtained by properly processed EPI-DTI at 7 T, and, with some reduction in efficiency and sharpness, TSE-DTI at 7 T. Furthermore, 7 T TSE-DTI shows promise in obtaining higher-resolution results in targeted acquisitions of specific brain areas. 相似文献