首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到8条相似文献,搜索用时 15 毫秒
1.
The optimal diffusion weighting (DW) factor, b, for use in diffusion tensor imaging (DTI) studies remains uncertain. In this study, the geometric relations of DW quantities are examined, in particular, the effects of Rician noise in the measured magnetic resonance signal. This geometric analysis is used to make theoretical predictions for selecting a b value to reduce the influence of noise. It is shown that the optimal b value for DTI studies in healthy human parenchyma is approximately b=1200 s mm−2, with a simple relation given as well for a given expected apparent diffusion coefficient. Monte-Carlo simulations on sets of realistic DTI measures are then performed, verifying the optimal DW for minimizing estimate errors. The effects of noise on various DTI parameters such as anisotropy indices (fractional anisotropy and scaled relative anisotropy), mean diffusivity, radial diffusivity, eigenvalues and the direction of the first eigenvector are investigated as well.  相似文献   

2.
Glaucoma is an optic neuropathy affecting the entire visual system. The understanding of the glaucoma mechanism and causes remains unresolved. Diffusion tensor imaging (DTI) has been used to analyze the optic nerve and optic radiation showing global fiber abnormalities associated with glaucoma. Nevertheless, the complex structure of the optic radiation and the limitations of DTI make the localization of the glaucoma effect a difficult task. The aim of this work is to establish a framework for the determination of the local changes of the optic radiation due to glaucoma using DTI. The proposed system utilizes a semiautomated algorithm to produce an efficient identification of the optic radiation. Segmented optic radiations are transformed to a unified space using shape-based nonrigid registration. Using the deformation fields that resulted from the registration, the maps of the diffusion tensor-derived parameters are transformed to the unified space. This allows for statistical voxel-wise analysis to produce significant abnormality maps. The proposed system is applied to a group of 13 glaucoma patients and a normal control group of 10 subjects. The groups are age matched to eliminate the age effect on the analysis. Diffusion-related parameters (axial, radial and mean diffusivities) and an anisotropy index (fractional anisotropy) are studied. The anisotropy analysis indicates that the majority of the significant voxels show decreased fractional anisotropy in the glaucoma patients compared with the control group. In addition, the significant regions are mainly distributed in the middle (in reference to anterior–posterior orientation) of the optic radiation. Glaucoma subjects have increased radial diffusivity and mean diffusivity significant voxels with a main concentration in the proximal part of the right optic radiation. The proposed analysis provides a framework to capture the significant local changes of the optic radiation due to glaucoma. The preliminary analysis suggests that the glaucomatous optic radiation may suffer from localized white matter degeneration. The framework facilitates further studies and understanding of the pathophysiology of glaucoma.  相似文献   

3.
The purpose of this study was to investigate myocardial fiber pathway distribution in order to provide supplemental information on myocardial fiber architecture and cardiac mechanics. Diffusion tensor imaging (DTI) with medium diffusion resolution (15 directions) was performed on normal canine heart samples (N=6) fixed in formalin. With the use of diffusion tensor fiber tracking, left ventricle (LV) myocardial fiber pathways and helix angles were computed pixel by pixel at short-axis slices from base to apex. Distribution of DTI-tracked fiber pathway length and number was analyzed quantitatively as a function of fiber helix angle in step of 9 degrees . The long fiber pathways were found to have small helix angles. They are mostly distributed in the middle myocardium and run circumferentially. Fiber pathways tracked at the middle and upper LV are generally longer than those near the apex. Majority of fiber pathways have small helix angles between -20 degrees and 20 degrees , dominating the fiber architecture in myocardium. Likely, such myocardial fiber pathway measurement by DTI may reflect the spatial connectiveness or connectivity of elastic myofiber bundles along their preferential pathway of electromechanical activation. The dominance of the long and circumferentially running fiber pathways found in the study may explain the circumferential predominance in left ventricular contraction.  相似文献   

4.
Diffusion tensor imaging (DTI) data often suffer from artifacts caused by motion. These artifacts are especially severe in DTI data from infants, and implementing tight quality controls is therefore imperative for DTI studies of infants. Currently, routine procedures for quality assurance of DTI data involve the slice-wise visual inspection of color-encoded, fractional anisotropy (CFA) images. Such procedures often yield inconsistent results across different data sets, across different operators who are examining those data sets, and sometimes even across time when the same operator inspects the same data set on two different occasions. We propose a more consistent, reliable, and effective method to evaluate the quality of CFA images automatically using their color cast, which is calculated on the distribution statistics of the 2D histogram in the color space as defined by the International Commission on Illumination (CIE) on lightness and a and b (LAB) for the color-opponent dimensions (also known as the CIELAB color space) of the images. Experimental results using DTI data acquired from neonates verified that this proposed method is rapid and accurate. The method thus provides a new tool for real-time quality assurance for DTI data.  相似文献   

5.

Purpose

To remove the partial volume averaging effect of free water in MR diffusion imaging of neural tissues by use of the fluid attenuated inversion recovery (FLAIR) without the penalty of an extended scan time.

Materials and methods

The magnetic resonance images were obtained from a normal volunteer in a coronal slice orientation at 3 T with the 20-channel rf coil. In diffusion imaging only the b0 images were obtained with the FLAIR contrast while the diffusion weighted images were obtained without the FLAIR contrast. A composition of FLAIR b0 and non-FLAIR diffusion weighted images was used in calculating the diffusion tensor and fractional anisotropy after compensating the reduced signal amplitude due to the inversion recovery in the FLAIR b0 images. The fractional anisotropy of the non-FLAIR, FLAIR, and the composite methods were analyzed for the mean and histogram in the corpus callosum, cervical spine, and the fornix tracts.

Results

The partial volume averaging effect was observed in the corpus callosum, the cervical spine, and the fornix tracts in the non-FLAIR b0 and diffusion images. The partial volume averaging effect was removed in the FLAIR diffusion images which took more than twice the scan time than the non-FLAIR diffusion imaging. The proposed composite FLAIR diffusion imaging removed the partial volume averaging effect as in the FLAIR diffusion imaging. The distribution of the FA histogram was very different between the non-FLAIR and FLAIR diffusion images, while it was very similar between the FLAIR and the composite FLAIR after correcting the white matter signal in the FLAIR b0 images.

Conclusions

The proposed composite FLAIR diffusion imaging method was equally effective in removing the partial volume averaging effect as the FLAIR diffusion imaging at a limited increase of the scan time since only a small number of b0 images needed to be obtained with the FLAIR contrast.  相似文献   

6.

Purpose

The articular cartilage is a small tissue with a matrix structure of three layers between which the orientation of collagen fiber differs. A diffusion-weighted twice-refocused spin-echo echo-planar imaging (SE-EPI) sequence was optimized for the articular cartilage, and the structure of the three layers of human articular cartilage was imaged in vivo from diffusion tensor images.

Materials and Methods

The subjects imaged were five specimens of swine femur head after removal of the flesh around the knee joint, five specimens of swine articular cartilage with flesh present and the knee cartilage of five adult male volunteers. Based on diffusion-weighted images in six directions, the mean diffusivity (MD) and the fractional anisotropy (FA) values were calculated.

Results

Diffusion tensor images of the articular cartilage were obtained by sequence optimization. The MD and FA value of the specimens (each of five examples) under different conditions were estimated. Although the articular cartilage is a small tissue, the matrix structure of each layer in the articular cartilage was obtained by SE-EPI sequence with GRAPPA. The MD and FA values of swine articular cartilage are different between the synovial fluid and saline. In human articular cartilage, the load of the body weight on the knee had an effect on the FA value of the surface layer of the articular cartilage.

Conclusion

This method can be used to create images of the articular cartilage structure, not only in vitro but also in vivo. Therefore, it is suggested that this method should support the elucidation of the in vivo structure and function of the knee joint and might be applied to clinical practice.  相似文献   

7.
Diffusion tensor magnetic resonance imaging (DTI) is useful for studying the microstructural changes in the spinal cord following traumatic injury; however, image quality is generally poor due to the small size of the spinal cord, physiological motion and susceptibility artifacts. Self-navigated, interleaved, variable-density spiral diffusion tensor imaging (SNAILS-DTI) is a distinctive pulse sequence that bypasses many of the challenges associated with DTI of the spinal cord, particularly if imaging gradient hardware is of conventional quality. In the current study, we have demonstrated the feasibility of implementing SNAILS-DTI on a clinical 3.0-T MR scanner and examined the effect of navigator filter parameters on image quality and reconstruction time. Results demonstrate high-quality, high-resolution (546 μm×546 μm) in vivo DTI images of the cat spinal cord after traumatic spinal cord injury.  相似文献   

8.
Diffusion tensor imaging requires correction of eddy current distortion in diffusion-weighted images. An effective retrospective correction approach is to transform a diffusion-weighted image to maximize the mutual information (MI) between the transformed diffusion-weighted image and the corresponding T2-weighted image. In the literature, either linear interpolation or partial volume interpolation is applied to estimate the MI objective function. However, these interpolation methods induce artifacts to the MI objective function, thus compromising correction results. In this work, the MI objective function is estimated based on interpolation using Fourier shift theorem. This method eliminates the artifacts incurred with the aforementioned interpolation methods. The algorithm is further improved by approximating pixel values using their nearest neighbors in the up-sampled spatial domain, resulting in dramatically increased computational efficiency without compromising the correction results. The effects of varying the number of quantization levels and using Parzen window filtering to smooth the MI objective function are also investigated to obtain optimized algorithm parameters. The diffusion tensor image quality after applying the proposed distortion correction method is significantly improved visually.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号