首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Molecular images of documents were obtained by sequentially scanning the surface of the document using desorption atmospheric pressure chemical ionization mass spectrometry (DAPCI‐MS), which was operated in either a gasless, solvent‐free or methanol vapor‐assisted mode. The decay process of the ink used for handwriting was monitored by following the signal intensities recorded by DAPCI‐MS. Handwritings made using four types of inks on four kinds of paper surfaces were tested. By studying the dynamic decay of the inks, DAPCI‐MS imaging differentiated a 10‐min old from two 4 h old samples. Non‐destructive forensic analysis of forged signatures either handwritten or computer‐assisted was achieved according to the difference of the contour in DAPCI images, which was attributed to the strength personalized by different writers. Distinction of the order of writing/stamping on documents and detection of illegal printings were accomplished with a spatial resolution of about 140 µm. A Matlab® written program was developed to facilitate the visualization of the similarity between signature images obtained by DAPCI‐MS. The experimental results show that DAPCI‐MS imaging provides rich information at the molecular level and thus can be used for the reliable document analysis in forensic applications. © 2013 The Authors. Journal of Mass Spectrometry published by John Wiley & Sons, Ltd.  相似文献   

2.
Super‐atmospheric pressure chemical ionization (APCI) mass spectrometry was performed using a commercial mass spectrometer by pressurizing the ion source with compressed air up to 7 atm. Similar to typical APCI source, reactant ions in the experiment were generated with corona discharge using a needle electrode. Although a higher needle potential was necessary to initiate the corona discharge, discharge current and detected ion signal were stable at all tested pressures. A Roots booster pump with variable pumping speed was installed between the evacuation port of the mass spectrometer and the original rough pumps to maintain a same pressure in the first pumping stage of the mass spectrometer regardless of ion source pressure. Measurement of gaseous methamphetamine and research department explosive showed an increase in ion intensity with the ion source pressure until an optimum pressure at around 4–5 atm. Beyond 5 atm, the ion intensity decreased with further increase of pressure, likely due to greater ion losses inside the ion transport capillary. For benzene, it was found that besides molecular ion and protonated species, ion due to [M + 2H]+ which was not so common in APCI, was also observed with high ion abundance under super‐atmospheric pressure condition. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
In this article, the effect of spray solvent on the analysis of selected lipids including fatty acids, fat‐soluble vitamins, triacylglycerols, steroids, phospholipids, and sphingolipids has been studied by two different ambient mass spectrometry (MS) methods, desorption electrospray ionization‐MS (DESI‐MS) and desorption atmospheric pressure photoionization‐MS (DAPPI‐MS). The ionization of the lipids with DESI and DAPPI was strongly dependent on the spray solvent. In most cases, the lipids were detected as protonated or deprotonated molecules; however, other ions were also formed, such as adduct ions (in DESI), [M‐H]+ ions (in DESI and DAPPI), radical ions (in DAPPI), and abundant oxidation products (in DESI and DAPPI). DAPPI provided efficient desorption and ionization for neutral and less polar as well as for ionic lipids but caused extensive fragmentation for larger and more labile compounds because of a thermal desorption process. DESI was more suitable for the analysis of the large and labile lipids, but the ionization efficiency for less polar lipids was poor. Both methods were successfully applied to the direct analysis of lipids from pharmaceutical and food products. Although DESI and DAPPI provide efficient analysis of lipids, the multiple and largely unpredictable ionization reactions may set challenges for routine lipid analysis with these methods. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
Ambient mass spectrometry, pioneered with desorption electrospray ionization (DESI) technique, is of increasing interest in recent years. In this study, a corona discharge ionization source is adapted for direct surface desorption chemical ionization of compounds on various surfaces at atmospheric pressure. Ambient air, with about 60% relative humidity, is used as a reagent to generate primary ions such as H(3)O(+), which is then directed to impact the sample surface for desorption and ionization. Under experimental conditions, protonated or deprotonated molecules of analytes present on various samples are observed using positive or negative corona discharge. Fast detection of trace amounts of analytes present in pharmaceutical preparations, viz foods, skins and clothes has been demonstrated without any sample pretreatment. Taking the advantage of the gasless setup, powder samples such as amino acids and mixtures of pharmaceutical preparations are rapidly analyzed. Impurities such as sudan dyes in tomato sauce are detected semiquantitatively. Molecular markers (e.g. putrescine) for meat spoilage are successfully identified from an artificially spoiled fish sample. Chemical warfare agent stimulants, explosives and herbicides are directly detected from the skin samples and clothing exposed to these compounds. This provides a detection limit of sub-pg (S/N > or = 3) range in MS2. Metabolites and consumed chemicals such as glucose are detected successfully from human skins. Conclusively, surface desorption atmospheric pressure chemical ionization (DAPCI) mass spectrometry, without toxic chemical contamination, detects various compounds in complex matrices, showing promising applications for analyses of human related samples.  相似文献   

5.
Clinically obtained human kidney stones of different pathogenesis were dissolved in acetic acid/methanol solutions and then rapidly analyzed by surface desorption atmospheric pressure chemical ionization mass spectrometry (SDAPCI-MS) without any desalination treatment. The mass spectral fingerprints of six groups of kidney stone samples were rapidly recorded in the mass range of m/z 50-400. A set of ten melamine-induced kidney stone samples and nine uric acid derived kidney stone samples were successfully differentiated from other groups by principal component analysis of SDAPCI-MS fingerprints upon positive-ion detection mode. In contrast, the mass spectra recorded using negative-ion detection mode did not give enough information to differentiate those stone samples. The results showed that in addition to the melamine, the chemical compounds enwrapped in the melamine-induced kidney stone samples differed from other kidney stone samples, providing useful hints for studying on the formation mechanisms of melamine-induced kidney stones. This study also provides useful information on establishing a MS-based platform for rapid analysis of the melamine-induced human kidney stones at molecular levels.  相似文献   

6.
The number and type of atmospheric pressure techniques suitable for sampling analytes from surfaces, forming ions from these analytes, and subsequently transporting these ions into vacuum for interrogation by MS have rapidly expanded over the last several years. Moreover, the literature in this area is complicated by an explosion in acronyms for these techniques, many of which provide no information relating to the chemical or physical processes involved. In this tutorial article, we sort this vast array of techniques into relatively few categories on the basis of the approaches used for surface sampling and ionization. For each technique, we explain, as best known, many of the underlying principles of operation, describe representative applications, and in some cases, discuss needed research or advancements and attempt to forecast their future analytical utility. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

7.
The applicability of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the detection of the free anabolic steroid fraction in human urine was examined. Electrospray ionization (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization methods were optimized regarding eluent composition, ion source parameters and fragmentation. The methods were compared with respect to specificity and detection limit. Although all methods proved suitable, LC/ESI-MS/MS with a methanol-water gradient including 5 mM ammonium acetate and 0.01% acetic acid was found best for the purpose. Multiple reaction monitoring allowed the determination of steroids in urine at low nanogram per milliliter levels. LC/MS/MS exhibited high sensitivity and specificity for the detection of free steroids and may be a suitable technique for screening for the abuse of anabolic steroids in sports.  相似文献   

8.
Pi Z  Yue H  Ma L  Ding L  Liu Z  Liu S 《Analytica chimica acta》2011,(2):285-290
Various kinds of Fructus schisandrae were studied by surface desorption atmospheric pressure chemical ionization mass spectrometry (DAPCI-MS) without any sample pretreatment. The volatile components in F. schisandrae were detected in the ambient environment and the analytical time for each sample was only 30 s. F. schisandrae are produced mainly in 5 different geographical regions (Elunchun, Mudanjiang, Tonghua, Tieling and Shangluo), and they could be successfully differentiated according to their chemical markers by Principal Component Analysis (PCA). A total of 8 components which gave more contribution for PCA analysis were unambiguously identified by comparison of the MS2 data of chemical markers to the data of reference compounds as reported in the literature. Similarly, wild grown and cultivatable species of F. schisandrae were well separated by the above-mentioned method. In addition, raw and processed cultivatable F. schisandrae (steamed by water, alcohol, vinegar, or honey, and fried by honey) were found to be clustered at different location, respectively. Furthermore, the clustered degree of differently processed products was correlated with their clinical effects. Our results demonstrated that DAPCI-MS in combination with PCA was a feasible technique for high-throughput differentiation of various kinds of F. schisandrae. It is also possible that DAPCI-MS could become a powerful technology in the studies of traditional Chinese medicine studies and in situ analysis of Chinese herbs.  相似文献   

9.
A new solid phase extraction (SPE) method coupled to a high throughput sample analysis technique was developed for the simultaneous determination of nine selected emerging contaminants in wastewater (atrazine, desethylatrazine, 17β-estradiol, ethynylestradiol, norethindrone, caffeine, carbamazepine, diclofenac and sulfamethoxazole). We specifically included pharmaceutical compounds from multiple therapeutic classes, as well as pesticides. Sample pre-concentration and clean-up was performed using a mixed-mode SPE cartridge (Strata ABW) having both cation and anion exchange properties, followed by analysis by laser diode thermal desorption atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). The LDTD interface is a new high-throughput sample introduction method, which reduces total analysis time to less than 15 s per sample as compared to minutes with traditional liquid-chromatography coupled to tandem mass spectrometry (LC–MS/MS). Several SPE parameters were evaluated in order to optimize recovery efficiencies when extracting analytes from wastewater, such as the nature of the stationary phase, the loading flow rate, the extraction pH, the volume and composition of the washing solution and the initial sample volume. The method was successfully applied to real wastewater samples from the primary sedimentation tank of a municipal wastewater treatment plant. Recoveries of target compounds from wastewater ranged from 78% to 106%, the limit of detection ranged from 30 to 122 ng L−1 while the limit of quantification ranged from 90 to 370 ng L−1. Calibration curves in the wastewater matrix showed good linearity (R2 ≥ 0.991) for all target analytes and the intraday and interday coefficient of variation was below 15%, reflecting a good precision.  相似文献   

10.
An atmospheric pressure photoionization (APPI) source and an atmospheric pressure chemical ionization (APCI) source were compared for the selective detection of microbial respiratory ubiquinone and menaquinone isoprenologues using tandem mass spectrometry. Ionization source- and compound mass-dependent parameters were optimized individually for both sources, using the available quinone standards. Detection levels for the two ion sources were determined with ubiquinone-6 (UQ6) and menaquinone-4 (MK4, vitamin K2) standards using flow injection analysis and selected reaction monitoring (SRM). With APPI the calculated lower limit of detection (LLOD) was 1.7 fmol microl(-1) for UQ6 and 2.2 fmol microl(-1) for MK4 at a signal-to-noise ratio of 3. These LLODs were at least three times lower than with APCI. The selectivity of detection afforded by SRM detection reduced complex mixture analysis to 3 min per sample by eliminating the need for chromatographic separations. The detection method was successfully applied to quinone quantification in a variety of environmental samples and cell cultures. Adequate amounts of respiratory quinones can be extracted and quantified from samples containing as low as 2 x 10(7) cells.  相似文献   

11.
Ambient desorption/ionization mass spectrometry (MS) has gained growing interest during the last decade due to its high analytical performance and yet simplicity. Here, one of the recently developed ambient desorption/ionization MS sources, the flowing atmospheric‐pressure afterglow (FAPA) source, was investigated in detail regarding background ions and typical ionization patterns in the positive as well as the negative ion mode for a variety of compound classes, comprising alkanes, alcohols, aldehydes, ketones, carboxylic acids, organic peroxides and alkaloids. A broad range of signals for adducts and losses was found, besides the usually emphasized detection of quasimolecular ions, i.e. [M + H]+ and [M ? H]? in the positive and the negative mode, respectively. It was found that FAPA–MS is best suited for polar analytes containing nitrogen and/or oxygen functionalities, e.g. carboxylic acids, with low molecular weights and relatively high vapor pressures. In addition, the source was used in proof‐of‐principle studies, illustrating the capabilities and limitations of the technique: Firstly, traces of cocaine were detected and unambiguously identified on euro banknotes using FAPA ionization in combination with tandem MS, suggesting a correlation between cocaine abundance and age of the banknote. Secondly, FAPA–MS was used for the identification of acidic marker compounds in organic aerosol samples, indicating yet‐undiscovered matrix and sample surface effects of ionization pathways in the afterglow region. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
Organic peroxides such as the cumene hydroperoxide I (M(r) = 152 u), the di-tert-butyl peroxide II (M(r) = 146 u) and the tert-butyl peroxybenzoate III (M(r) = 194 u) were analyzed by atmospheric pressure chemical ionization mass spectrometry using a water-methanol mixture as solvent with a low flow-rate of mobile phase and unusual conditions of the source temperature (< or =50 degrees C) and probe temperature (70-200 degrees C). The mass spectra of these compounds show the formation of (i) an [M + H](+) ion (m/z 153) for the hydroperoxide I, (ii) a stable adduct [M + CH(3)OH(2)](+) ion (m/z 179) for the dialkyl peroxide II and (iii) several protonated adduct species such as protonated molecules (m/z 195) and different protonated adduct ions (m/z 227, 389 and 421) for the peroxyester III. Tandem mass spectrometric experiments, exact mass measurements and theoretical calculations were performed for characterize these gas-phase ionic species. Using the double-well energy potential model illustrating a gas-phase bimolecular reaction, three important factors are taken into account to propose a qualitative interpretation of peroxide behavior toward the CH(3)OH(2) (+), i.e. thermochemical parameters (DeltaHdegrees(reaction)) and two kinetic factors such as the capture constant of the initial stable ion-dipole and the magnitude of the rate constant of proton transfer reaction into the loose proton bond cluster.  相似文献   

13.
The potential applications of a new atmospheric pressure source for GC‐MS analysis have been investigated in this work. A list of around 100 GC‐amenable pesticides, which includes organochlorine, organophosphorus and organonitrogenated compounds, has been used to evaluate their behavior in the new source. Favoring the major formation of the molecular ion in the source has been the main goal due to the wide‐scope screening possibilities that this fact brings in comparison with the traditional, highly fragmented electron ionization spectra. Thus, the addition of water as modifier has been tested as a way to promote the generation of protonated molecules. Pesticides investigated have been classified into six groups according to their ionization/fragmentation behavior. Four of them are characterized by the abundant formation of the protonated molecule in the atmospheric pressure source, mostly being the base peak of the spectrum. These results show that wide‐scope screening could be easily performed with this source by investigating the presence of the protonated molecule ion, MH+. The developed procedure has been applied to pesticide screening in different food samples (nectarine, orange and spinach) and it has allowed the presence of several pesticides to be confirmed such as chlorpyriphos ethyl, deltamethrin and endosulfan sulfate. The availability of a quadrupole time‐of‐flight instrument made it feasible to perform additional MS/MS experiments for both standards and samples to go further in the confirmation of the identity of the detected compounds. Results shown in this paper have been obtained using a prototype source which exhibits promising features that could be applied to other analytical problems apart from those illustrated in this work. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
A high-throughput method is presented for the determination of rotenone in contaminated matrices. The procedure involves atmospheric pressure chemical ionization tandem mass spectrometry with a triple-quadrupole instrument and the use as internal standard of a cycloadduct derivative of rotenone itself. The method was applied to the evaluation of the decay of rotenone in olives and olive oil at various times after exposure to the contaminant.  相似文献   

15.
Atmospheric pressure (AP) matrix‐assisted laser desorption/ionization (MALDI) is known to suffer from poor ion transfer efficiencies as compared to conventional vacuum MALDI (vMALDI). To mitigate these issues, a new AP‐MALDI ion source utilizing a coaxial gas flow was developed. Nitrogen, helium, and sulfur hexafluoride were tested for their abilities as ion carriers for a standard peptide and small drug molecules. Nitrogen showed the best ion transport efficiency, with sensitivity gains of up to 1900% and 20% for a peptide standard when the target plate voltage was either continuous or pulsed, respectively. The addition of carrier gas not only entrained the ions efficiently but also deflected background species and declustered analyte–matrix adducts, resulting in higher absolute analyte signal intensities and greater signal‐to‐noise (S/N) ratios. With the increased sensitivity of pneumatically assisted (PA) AP‐MALDI, the limits of detection of angiotensin I were 20 or 3 fmols for continuous or pulsed target plate voltage, respectively. For analyzing low‐mass analytes, it was found that very low gas flow rates (0.3–0.6 l min?1) were preferable owing to increased fragmentation at higher gas flows. The analyte lability, type of gas, and nature of the extraction field between the target plate and mass spectrometer inlet were observed to be the most important factors affecting the performance of the in‐line PA‐AP‐MALDI ion source. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
大气压离子化技术/飞行时间质谱联用进展   总被引:1,自引:0,他引:1  
综述了大气压离子化技术/飞行时间质谱联用技术及其应用的进展  相似文献   

17.
用液相色谱/大气压化学电离离子阱质谱建立了一种分析烟草中游离茄尼醇的方法。烟草样品用甲醇振荡提取30 min,在分析前无需进行其它前处理。在1.8μm快速分离C18色谱短柱上用V(甲醇)∶V(异丙醇)=85∶15等梯度洗脱实现了茄尼醇的快速分离。用不带碰撞能量的二级质谱全扫描选择监测离子m/z 613.6进行定量,检出限为0.4μg/L,RSD为1.1%,两种添加量的回收率分别为97%和99%。方法应用于不同烟草和烟草制品样品的检测分析。  相似文献   

18.
N‐Hydroxylated polyamine derivatives were found to decompose during the ionization process of liquid chromatography‐atmospheric pressure chemical ionization‐mass spectrometry (LC‐APCI‐MS) experiments. The phenomenon was studied with a model compound, a synthetic N‐hydroxylated tetraamine derivative. It was found that reduction, oxidation and water elimination occurred during APCI to generate the corresponding amine, N‐oxide, and imine. The investigation further revealed that decomposition of hydroxylamines during APCI depends upon the concentration of the analyte and on the acidity of the solution introduced into the ionization source. The pH‐dependence of decomposition was utilized for the development of an MS method that allows for the unambiguous identification of N? OH functionalities. This method was applied for the study of natural products including polyamine toxins from the venom of the spider Agelenopsis aperta and mayfoline, a cyclic polyamine derivative of the shrub Maytenus buxifolia. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
The suitability of atmospheric pressure desorption/ionization on silicon mass spectrometry (AP-DIOS-MS) and matrix-assisted laser desorption ionization mass spectrometry (AP-MALDI-MS) for the identification of amphetamines and fentanyls in forensic samples was studied. With both ionization techniques, the mass spectra recorded showed abundant protonated molecules, and the background did not disturb the analysis. The use of tandem mass spectrometry (MS/MS) allowed unambiguous identification of the amphetamines and fentanyls. AP-DIOS-MS/MS and AP-MALDI-MS/MS were also successfully applied to the identification of authentic compounds from drug seizures. Common diluents and tablet materials did not disturb the analysis and compounds were unequivocally identified. The limits of detection (LODs) for amphetamines and fentanyls with AP-DIOS-MS/MS were 1-3 pmol, indicating excellent sensitivity of the method. The LODs with AP-MALDI-MS/MS were about 5-10 times higher.  相似文献   

20.
An atmospheric pressure (AP) infrared (IR) laser ionization technique, implemented on a quadrupole ion trap mass spectrometer, was used to analyze underivatized, N-linked oligosaccharides in solution. Experiments were conducted on an atmospheric pressure infrared ionization from solution (AP-IRIS) ion source which differed from previous AP IR matrix-assisted laser desorption/ionization (MALDI) interfaces in that the ion source operated in the absence of an extraction electric field with a higher power 2.94 microm IR laser. The general term 'IRIS' is used as the mechanism of ionization differs from that of MALDI, and is yet to be fully elucidated. The AP-IRIS ion source demonstrated femtomole-level sensitivity for branched oligosaccharides. AP-IRIS showed approximately 16 times improved sensitivity for oligomannose-6 and the core-fucosylated glycan M3N2F over optimal results obtainable on a AP UV-MALDI with a 2,4,6-trihydroxyacetophenone matrix. Comparison between IR and UV cases also showed less fragmentation in the IR spectrum for a glycan with a conserved trimannosyl core, core-substituted with fucose. A mixture of complex, high-mannose and sialylated glycans resulted in positive ion mass spectra with molecular ion peaks for each sugar. Tandem mass spectrometry of the sodiated molecular ions in a mixture of glycans revealed primarily glycosidic (B, Y) cleavages. The reported results show the practical utility of AP-IRIS while the ionization mechanism is still under investigation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏