共查询到20条相似文献,搜索用时 15 毫秒
1.
An easy, simple, and highly efficient on-line preconcentration method for polyphenolic compounds in CE was developed. It combined two on-line concentration techniques, large-volume sample stacking (LVSS) and sweeping. The analytes preconcentration technique was carried out by pressure injection of large-volume sample followed by the EOF as a pump pushing the bulk of low-conductivity sample matrix out of the outlet of the capillary without the electrode polarity switching technique using five polyphenols as the model analytes. Identification and quantification of the analytes were performed by photodiode array UV (PDA) detection. The optimal BGE used for separation and preconcentration was a solution composed of 10 mM borate-90 mM sodium cholate (SC)-40% v/v ethylene glycol, without pH adjustment, the applied voltage was 27.5 kV. Under optimal preconcentration conditions (sample injection 99 s at 0.5 psi), the enhancement in the detection sensitivities of the peak height and peak area of the analytes using the on-line concentration technique was in the range of 18-26- and 23-44-fold comparing with the conventional injection mode (3 s). The detection limits for (-)-epigallocatechin (EGC), (-)-epicatechin (EC), (+)-catechin (C), (-)-epigallocatechin gallate (EGCG), and (-)-epicatechin gallate (ECG) were 4.3, 2.4, 2.2, 2.0, and 1.6 ng/mL, respectively. The five analytes were baseline-separated under the optimum conditions and the experimental results showed that preconcentration was well achieved. 相似文献
2.
On-line determination of the anti-tumor drug 5-fluorouracil (5-FU) and its prodrug, tegafur (TF) was achieved for the first time by capillary electrophoresis with large-volume sample stacking (CE-LVSS). The optimal electrophoretic buffer consisted of 30 mM phosphate buffer at pH 8.0. Without the LVSS procedure, the limits of detection (LOD) were 600.5 ng/mL and 771.4 ng/mL for 5-FU and TF, respectively. With the LVSS procedure, the sensitivity was significantly improved by about two orders of magnitude (the LODs of 5-FU and TF were decreased to 7.9 ng/mL and 6.5 ng/mL, respectively). The %RSD was less than 5%. This method compared favorably with other reported techniques and was applied successfully to the quantitative analysis of anti-tumor drugs in commercial injection preparations. The results show that the method is simple, fast (less than 3 min), highly selective, and sensitive. 相似文献
3.
This paper aimed to build up a sensitive CE method for the analysis of tetracyclines (TCs) antibiotics (including tetracycline, chlorotetracycline, oxytetracycline, and doxycycline) with conventional UV detection. Here, the large volume sample stacking was applied to achieve in capillary preconcentration of the targets. To achieve large volume sample stacking, the essential step was a large volume of sample (around 83.3% of total capillary length from inlet to detection window) hydrodynamically loaded. Then, the reserved voltage was added in order to push the sample matrix out of the capillary. Due to different pH between sample solution (pH 4.6) and BGE (pH 11.0), the cationic TCs would turn into negatively charged while the sample matrix was removing from the capillary. Finally, the anionic TCs were stacked at the inlet for the subsequent separation. Although the loss of sample existed during their charge transformation, the LODs could be improved around 40 times than that obtained by normal hydrodynamic injection CE method. Here, the LODs were in the range of 8.1–14.5 μg/L, around 10 ppb that close to the level by electrochemiluminescence or laser‐induced fluorescence detection of TCs by CE. The precision was characterized by RSDs of migration times and peak areas, which were in the range of 0.19–0.24% and 0.97–2.54%, respectively. The recoveries of the developed method were in the range of 95–112% by spiking TCs in the tap water. The proposed inline preconcentration CE method could be a simple, speed, and sensitive method for the quantitative analysis of TCs. 相似文献
4.
《Biomedical chromatography : BMC》2018,32(3)
Large‐volume sample stacking (LVSS) is commonly used as an effective online preconcentration method in capillary zone electrophoresis (CZE). In this paper, the method LVSS combined with CZE has been proposed to analyze camptothecin alkaloids. Optimum separation can be achieved in the following conditions: pH 9.0; 25mm borate buffer containing 20 mm sulfobutylether‐β‐cyclodextrin and 20 mm ionic liquid 1‐ethyl‐3‐methyllimidazole l ‐lactate; applied voltage 20 kV; and capillary temperature 25 °C. The LVSS was optimized as hydrodynamic injection 4 s at 5.0 psi and the polarity switching time was 0.17 min. Under the above conditions, the analytes could be separated completely in <20 min and the detector response was increased compared with conventional hydrodynamic injection. The limits of detection were between 0.20 and 0.78 μg/L. A good linearity was obtained with correlation coefficients from 0.9991 to 0.9997. The recoveries ranged from 97.72 to 103.2% and the results demonstrated excellent accuracy. In terms of the migration time and peak area, the experiment was reproducible. The experimental results indicated that baseline separation can be obtained and this method is suitable for the quantitative determination of camptothecin alkaloids in real samples. 相似文献
5.
This study describes approaches for stacking a large volume of sample solutions containing a mixture of mercaptopurine monohydrate, 6-methylmercaptopurine, thioguanine, thioguanosine, and thioxanthine in capillary electrophoresis (CE). After filling the run buffer (60 mM borate buffer, pH 8.5), a large sample volume was loaded by hydrodynamic injection (2.5 psi, 99.9 s), followed by the removal of the large plug of sample matrix from the capillary using polarity switching (-15 kV). Monitoring the current and reversing the polarity when 95% of current recovered, the separation of anionic analytes was performed in a run buffer < 20 kV. Around 44- to 90-fold improvement of sensitivity for five analytes was achieved by large-volume stacking with polarity switching when compared with CE without stacking. This method was feasible for determination of the analytes spiked in plasma. Removing most of electrolytes from plasma is a key step for performing large-volume sample stacking. Solid-phase extraction was used for pretreatment of biological samples. To our knowledge, this study is one of few applications showing the possibilities of this stacking procedure to analyze biological samples by large-volume sample stacking with polarity switching (LVSSPS) in CE. 相似文献
6.
Palmer JF 《Journal of chromatography. A》2004,1036(2):95-100
High-salt stacking in electrokinetic chromatography (EKC) is defined and contrasted to the sweeping method. A recent paper argued the two methods are identical, where high concentrations of micelle in the sample were intended to mimic the effect of high-salt stacking. However, high micelle concentration in the sample matrix in EKC is analogous to using a high-conductivity sample instead of a low-conductivity sample in field amplified stacking. High-salt stacking does not require a sample free of pseuostationary phase, only a sample with a high-mobility co-ion compared to the separation buffer electrokinetic vector. High-salt stacking uses a discontinuous buffer system and should not be confused with continuous buffer stacking systems such as sweeping. 相似文献
7.
Several strategies, namely, large volume sample stacking (LVSS), field‐amplified sample injection (FASI), sweeping, and in‐line SPE‐CE, were investigated for the simultaneous separation and preconcentration of a group of parabens. A BGE consisting of 20 mM sodium dihydrogenphosphate (pH 2.28) and 150 mM SDS with 15% ACN was used for the separation and preconcentration of the compounds by sweeping, and a BGE consisting of 30 mM sodium borate (pH 9.5) was used for the separation and preconcentration of the compounds by LVSS, FASI, and in‐line SPE‐CE. Several factors affecting the preconcentration process were investigated in order to obtain the maximum enhancement of sensitivity. The LODs obtained for parabens were in the range of 18–27, 3–4, 2, and 0.01–0.02 ng/mL, and the sensitivity evaluated in terms of LODs was improved up to 29‐, 77‐, 120‐, and 18 400‐fold for sweeping, LVSS, FASI, and in‐line SPE‐CE, respectively. These preconcentration techniques showed potential as good strategies for focusing parabens. The four methods were validated with standard samples to show the potential of these techniques for future applications in real samples, such as biological and environmental samples. 相似文献
8.
This paper describes approaches for large-volume sample stacking (LVSS) with an EOF pumpin CE for the determination of methotrexate (MTX) and its metabolites in human plasma. After pretreatment of plasma through a SPE cartridge, a large sample volume was loaded by hydrodynamic injection (3 psi, 70 s) into the capillary filled with phosphate buffer (70 mM, pH 6.0) containing 0.01% polyethylene oxide. Following removal of a large plug of sample matrix from the capillary using polarity switching (-25 kV), the separation of anionic analytes was subsequently performed without changing polarity again, achieving an improvement of sensitivity of around a 100-fold. The method was applied to therapeutic drug monitoring of MTX in one acute lymphoblastic leukemia patient. This study is one of very few applications showing the feasibility of LVSS in analysis of biological samples by CE. 相似文献
9.
Large‐volume sample stacking with polarity switching for monitoring of nucleotide pyrophosphatase/phosphodiesterase 1 (NPP1) reactions by capillary electrophoresis 下载免费PDF全文
Nucleotide pyrophosphatase/phosphodiesterase 1 (NPP1) is a membrane glycoprotein involved in the hydrolysis of extracellular nucleotides. Its main substrate is ATP yielding AMP and pyrophosphate. NPP1 has been proposed as a novel drug target, for diabetes type 2 and the treatment of calcium pyrophosphate dihydrate deposition disease leading to inflammatory arthritis. The monitoring of NPP1 reactions is difficult because its velocity is very slow requiring highly sensitive analytical procedures. In this study, a method of large‐volume sample stacking with polarity switching was developed, and separations were optimized. Large sample volumes were loaded by hydrodynamic injection (5 psi, 13 s) followed by removal of a large plug of sample matrix from the capillary using polarity switching (?10 kV). The stacked analytes were subsequently separated in phosphate buffer (100 mM, pH 9.2) at 20 kV. The validated method was found to be linear (R2 = 0.9927) in the concentration range of 0.05–50 μM of AMP, with high accuracy and precision. The determined LOD and LOQ of AMP were 18 nM and 60 nM, respectively. Compared to a previously reported CE procedure using sweeping technique, a fivefold improvement of sensitivity was achieved. Moreover, the new technique was faster, and reproducibility of migration times was improved (RSD value = 1.2%). Importantly, adenine nucleotide analogs and derivatives tested as NPP1 inhibitors could be completely separated from the substrate ATP and the enzymatic product AMP. The method was applied to NPP1 inhibition assays investigating nucleotide‐derived inhibitors in the presence of ATP. 相似文献
10.
采用大体积样品堆积(LVSS)在线富集模式,建立了高效毛细管电泳(HPCE)测定蒲公英中阿魏酸、绿原酸和咖啡酸含量的方法。主要考察了在毛细管区带电泳(CZE)分离模式下,缓冲液的pH和浓度对分离效果的影响,以及在LVSS在线富集模式下,进样时间对富集效果的影响。在最优条件下阿魏酸、绿原酸和咖啡酸可在12 min内得到分离,3个成分在0.5~25.0μg/mL浓度范围内均有较好的线性关系(r2=0.999),平均加样回收率分别为104.9%,98.0%和100.1%,RSD(n=6)分别为3.6%,2.6%和1.0%。定量限(S/N=10)分别为0.10,0.10和0.03μg/mL,检出限(S/N=3)分别为0.03,0.03和0.01μg/mL。相对于常规CZE模式,本方法的富集效果倍数为17~19倍。建立的方法可用于蒲公英的日常检测与质量控制。 相似文献
11.
Soto-Chinchilla JJ García-Campaña AM Gámiz-Gracia L Cruces-Blanco C 《Electrophoresis》2006,27(20):4060-4068
A CZE method with UV-Vis detection has been established and validated for the determination of nine sulfonamides: sulfapyridine, sulfamethazine, sulfamerazine, sulfamether, sulfadiazine, sulfadimethoxine, sulfamethoxazole, sulfachlorpyridazine, and sulfamethizole. Optimum separation was obtained on a 64.5 cm x 75 microm bubble cell capillary using a buffer containing 45 mM sodium phosphate and 10% methanol at pH 7.3, with temperature and voltage of 27 degrees C and 25 kV, respectively. p-Aminobenzoic acid was used as an internal standard . Taking into account the lack of sensitivity of the UV-Vis detection, the application of an on-line preconcentration methodology, such as large-volume sample stacking with polarity switching has been proposed. This procedure combined with a solvent extraction/SPE method applied for off-line preconcentration and cleanup provides a significant improvement in the LODs, ranging from 2.59 to 22.95 mug/L for the studied compounds; the quantification of these residues being possible below the levels established by EU legislation in animal food products, such as meat. Satisfactory recoveries were also obtained in the analysis of these compounds in ground water. 相似文献
12.
Herrera-Herrera AV Ravelo-Pérez LM Hernández-Borges J Afonso MM Palenzuela JA Rodríguez-Delgado MÁ 《Journal of chromatography. A》2011,1218(31):5352-5361
In this work, a new method for the determination of eleven quinolone antibiotics (moxifloxacin, lomefloxacin, danofloxacin, ciprofloxacin, levofloxacin, marbofloxacin, enrofloxacin, difloxacin, pefloxacin, oxolinic acid and flumequine) in different water samples using dispersive solid-phase extraction (dSPE) and capillary zone electrophoresis with diode-array detection was developed. Oxidized multi-walled carbon nanotubes (o-MWCNTs) were used for the first time as stationary phases for the off-line preconcentration by dSPE of the antibiotics. A 65 mM phosphate buffer at pH 8.5 was found adequate for analyte separation while large volume sample stacking with polarity switching of the analytes dissolved in water containing 10% (v/v) of acetonitrile was carried out in order to improve the sensitivity. dSPE parameters, such as sample volume and pH, o-MWCNT amount, volume and type of eluent in dSPE were optimized. Application of the developed method to the analysis of spiked Milli-Q, mineral, tap, and wastewater samples resulted in good recoveries values ranging from 62.3 to 116% with relative standard deviation values lower than 7.7% in all cases. Limits of detection were in the range of 28-94 ng/L. The proposed method is very fast, simple, repeatable, accurate and highly selective. 相似文献
13.
Interface‐free two‐dimensional heart‐cutting capillary electrophoresis for the separation and stacking of anionic and neutral analytes 下载免费PDF全文
Chunyapuk Kukusamude Supalax Srijaranai Joselito P. Quirino 《Journal of separation science》2015,38(14):2532-2537
Interface‐free two‐dimensional heart‐cutting capillary electrophoresis for two different classes of analytes (anionic and neutral) in a single capillary is presented. Simultaneous sample stacking and orthogonal separation were demonstrated. The anionic species were first analyzed by capillary zone electrophoresis in the first dimension. Then, the neutral compounds were separated in the second dimension by micellar electrokinetic chromatography using the common anionic surfactant sodium dodecyl sulfate. The first and second dimensions occurred automatically without changing the electrolyte and without polarity switching. Artificial mixtures (five anions and four neutral compounds) were successfully analyzed with sensitivity enhancement factors from 7 to 28. The orthogonal separation was complete within 8 min. Some analytical features and application to a spiked real river water sample were also studied. 相似文献
14.
Quirino JP 《Journal of chromatography. A》2010,1217(49):7776-7780
Two-step stacking of organic cations by sweeping and micelle to solvent stacking (MSS) in capillary zone electrophoresis (CZE) is presented. The simple procedure involves hydrodynamic injection of a micellar sodium dodecyl sulfate solution before the sample that is prepared without the micelles. The micelles sweep and transport the cations to the boundary zone between the sample and CZE buffer. The presence of organic solvent in the CZE buffer induces the second stacking step of MSS. The LODs obtained for the four beta blocker and two tricyclic antidepressant test drugs were 20-50 times better compared to typical injection. 相似文献
15.
Man-Seog Chun 《Analytica chimica acta》2003,491(2):173-179
Large volume stacking using the electroosmotic flow (EOF) pump (LVSEP) in capillary electrophoresis under a reverse potential is a convenient and straightforward approach for on-line concentration of dilute anionic sample solutions. LVSEP achieves automatic sample matrix removal and subsequent separation without intermediate polarity switching nor complicated instrumental setup. Since anionic analytes should move against the EOF in LVSEP, EOF needs to be suppressed. We extended the range of LVSEP up to pH 11 using various EOF suppression methods, such as dynamic coating by polymer pretreatment and permanent coating. Weakly acidic organic compounds (pKa<5.2), chlorinated phenols (pKa=7-9), and aromatic amino acids (pKa2∼9.3) were concentrated and separated. By hydrodynamically filling the whole capillary of 27 cm long with the sample solution, fast and reliable injection was achieved and sensitivity enhancement factors as large as 170 were readily obtained in less than 8 min. 相似文献
16.
Anionic microemulsion to solvent stacking for on‐line sample concentration of cationic analytes in capillary electrophoresis 下载免费PDF全文
The common SDS microemulsion (i.e. 3.3% SDS, 0.8% octane, and 6.6% butanol) and organic solvents were investigated for the stacking of cationic drugs in capillary zone electrophoresis using a low pH separation electrolyte. The sample was prepared in the acidic microemulsion and a high percentage of organic solvent was included in the electrolyte at anodic end of capillary. The stacking mechanism was similar to micelle to solvent stacking where the micelles were replaced by the microemulsion for the transport of analytes to the organic solvent rich boundary. This boundary is found between the microemulsion and anodic electrolyte. The effective electrophoretic mobility of the cations reversed from the direction of the anode in the microemulsion to the cathode in the boundary. Microemulsion to solvent stacking was successfully achieved with 40% ACN in the anodic electrolyte and hydrodynamic sample injection of 21 s at 1000 mbar (equivalent to 30% of the effective length). The sensitivity enhancement factors in terms of peak height and corrected peak area were 15 to 35 and 21 to 47, respectively. The linearity R2 in terms of corrected peak area were >0.999. Interday precisions (%RSD, n = 6) were 3.3–4.0% for corrected peak area and 2.0–3.0% for migration time. Application to spiked real sample is also presented. 相似文献
17.
Two-step stacking of organic anions by sweeping and micelle to solvent stacking (MSS) using cationic cetyltrimethylammonium micelles in co-electroosmotic flow (co-EOF) capillary zone electrophoresis (CZE) is described. The co-EOF condition where the direction of the EOF is the same as the test anions was satisfied by positive dynamic coating of a fused silica capillary with hexadimethrine bromide. The strategy was as follows. After conditioning the capillary with the background solution (BGS), a micellar solution (MS) was injected before the sample solution (S). The BGS, MS and S have similar conductivities. Voltage was applied at negative polarity. The analytes in the micelle-free S zone were swept by micelles from the MS. The swept analytes were brought by the micelles to the MSS boundary where the second stacking step was induced by the presence of organic solvent in the BGS. Finally was the separation of concentrated analytes by CZE. The effect of electrolyte concentration in the S, injection time of the MS and the S and surfactant concentration in the MS were studied. A 20-29, 17-33 and 18-21 times increase in peak height sensitivity was obtained for the test hypolipidaemic drugs (gemfibrozil, fluvastatin and atorvastatin), non-steroidal anti-inflammatory drugs (diflunisal, naproxen, ketoprofen, indoprofen and indomethacin), and herbicides (mecoprop and fenoprop), respectively. The LODs (S/N=3) were from 0.05 to 0.55 μg/mL. The intraday and interday repeatabilities (%RSD, n=12) in terms of retention time, corrected peak area, and peak heights was less than 3.6, 8.9, and 10.8%, respectively. The application of sweeping and MSS in co-EOF CZE together with a simple extraction procedure to a waste water sample spiked with the test herbicides was also demonstrated. 相似文献
18.
A capillary electrophoresis method has been developed for the simultaneous analysis of the oxidized, nitrated, and chlorinated aromatic amino acids, as well as their parent compounds. These modifications of the aromatic amino acids in proteins or free form are induced by the attack of reactive, mainly free radical species generated during cell stress, and these stable products may serve as biomarkers of cell damage. The analytes tyrosine, phenylalanine, dihydroxyphenylalanine, tryptophan, 3-nitrotyrosine, 3-chlorotyrosine, ortho-tyrosine, meta-tyrosine, 3-hydroxyphenylacetic acid (internal standard 1), and alpha-methyltyrosine (internal standard 2) were separated in their anionic forms in alkaline borate buffer. The polyamine spermine was used as electroosmotic flow (EOF) modifier. Adsorbing to the capillary wall, spermine can either suppress or even reverse the EOF depending on its concentration and the pH. The effects of the pH of the separation buffer, the spermine concentration, the temperature, and the applied field strength on the separation were examined. The modified aromatic amino acids are present in biological fluids in a much lower concentration than their parent compounds, thus high detection sensitivity of the analytical method is required. To achieve good detection sensitivity, field-amplified sample stacking of large injection volumes was applied. Omitting polyamine from the sample buffer allowed local reversal of the EOF, thus removal of the low conductivity sample buffer at the capillary inlet. In this way, 100% of the capillary to the detection window could be filled with the sample, and the detection limits achieved for the modified aromatic amino acids were in the range of 2.5-10 nM. 相似文献
19.
Single drop microextraction (SDME) is a convenient and powerful preconcentration method for CE before injection. By simple combination of sample‐handling sequences without modification of the CE apparatus, a drop of an aqueous acceptor phase covered with a thin organic layer was formed at the tip of a capillary; 10 min SDME of fluorescein and 6‐carboxyfluorescein from a donor phase of pH 1 to an acceptor phase of pH 9 provided 110‐fold enrichments without stirring the donor phase. To improve the concentration effect further, SDME was coupled with an on‐line (after injection) sample preconcentration method, sweeping, in which analytes in a long sample zone are accumulated at the boundary of a pseudostationary phase penetrating into the sample zone. It is thus necessary to inject a sample of much larger volume than that of a drop in typical SDME. A Teflon sleeve over the capillary inlet allowed a large volume drop to be held stably during extraction. By in‐line coupling 10 min SDME and sweeping of a 30 nL sample using a cationic surfactant dodecyltrimethylammonium, enrichment factors of the double preconcentration were increased up to 32 000. 相似文献
20.
Simultaneous electrokinetic and hydrodynamic injection (SEHI) of organic cations (tricyclic antidepressant and beta blocker drugs) with on-line sample concentration using micelle to solvent stacking (MSS) was studied in micellar electrokinetic chromatography. Compared to conventional injection, >300-fold improvements in signals were obtained by hydrodynamic injection. However, with SEHI the amount of sample ions introduced into the capillary was increased which afforded a higher gain of up to 4000-fold without compromise to separation efficiency. The electrokinetic injection at negative polarity (anode at the detector end) introduced the micelle bound analytes. The hydrodynamic injection also maintained the MSS boundary inside the capillary. The stability of the MSS boundary affected SEHI where mild conditions that were low voltage as well as pressure injection were desired. The limits of detection were in the range from 0.6–4.2 ng mL−1. A strategy for optimization was described and the method was applied to the ng mL−1 analysis of spiked wastewater after simple dilution and centrifugation. 相似文献