首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a powerful tool for the analysis and characterization of protein phosphorylation on the peptide level. In this study, the applicability of ionic liquid matrices (ILM) formed by combination of the crystalline MALDI matrix 2,5-dihydroxybenzoic acid (DHB) with pyridine or n-butylamine was tested for the analysis of phosphopeptides. Low ionization efficiency in both positive and negative ion mode was observed in acid-free sample preparations. Upon addition of 0.1% trifluoroacetic acid (TFA), ion formation was increased, but analogously to the situation described earlier for pure DHB, best results were obtained upon use of 1% phosphoric acid as matrix additive. The samples prepared in this way were significantly more homogeneous than preparations with pure DHB, thus avoiding the need for time-consuming search for hot spots. Other characteristics like metastable fragmentation of phosphopeptides did not differ from that observed in classical preparations. The limits of detection for synthetic phosphopeptides and singly or multiply phosphorylated peptides from tryptic digests of alpha- and beta-casein were comparable with those obtained when using pure DHB; in some cases even higher signal intensities could be observed in the ILM. The use of ILM in combination with 1% phosphoric acid as matrix additive significantly facilitates analysis of phosphopeptides by MALDI-MS.  相似文献   

2.
In order to investigate gas‐phase fragmentation reactions of phosphorylated peptide ions, matrix‐assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) tandem mass (MS/MS) spectra were recorded from synthetic phosphopeptides and from phosphopeptides isolated from natural sources. MALDI‐TOF/TOF (TOF: time‐of‐flight) spectra of synthetic arginine‐containing phosphopeptides revealed a significant increase of y ions resulting from bond cleavages on the C‐terminal side of phosphothreonine or phosphoserine. The same effect was found in ESI‐MS/MS spectra recorded from the singly charged but not from the doubly charged ions of these phosphopeptides. ESI‐MS/MS spectra of doubly charged phosphopeptides containing two arginine residues support the following general fragmentation rule: Increased amide bond cleavage on the C‐terminal side of phosphorylated serines or threonines mainly occurs in peptide ions which do not contain mobile protons. In MALDI‐TOF/TOF spectra of phosphopeptides displaying N‐terminal fragment ions, abundant b–H3PO4 ions resulting from the enhanced dissociation of the pSer/pThr–X bond were detected (X denotes amino acids). Cleavages at phosphoamino acids were found to be particularly predominant in spectra of phosphopeptides containing pSer/pThr–Pro bonds. A quantitative evaluation of a larger set of MALDI‐TOF/TOF spectra recorded from phosphopeptides indicated that phosphoserine residues in arginine‐containing peptides increase the signal intensities of the respective y ions by almost a factor of 3. A less pronounced cleavage‐enhancing effect was observed in some lysine‐containing phosphopeptides without arginine. The proposed peptide fragmentation pathways involve a nucleophilic attack by phosphate oxygen on the carbon center of the peptide backbone amide, which eventually leads to cleavage of the amide bond. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
There have been many successful efforts to enrich phosphopeptides in complex protein mixtures by the use of immobilized metal affinity chromatography (IMAC) and/or metal oxide affinity chromatography (MOAC) with which mass spectrometric analysis of phosphopeptides has become state of the art in specialized laboratories, mostly applying nanoLC electrospray ionization mass spectrometry-based investigations. However, widespread use of these powerful techniques is still not achieved. In this study, we present a ready-to-use phosphopeptide enrichment procedure using commercially available TiO(2)-loaded pipette tips in combination with matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) analyses. Using α-casein as a model protein and citric acid as additive during sample loading, a similar enrichment success can be achieved as compared to applying 2,5- dihydroxy benzoic acid (DHB) for this task. But the DHB-inherited drawbacks are eliminated. In addition, we show that combining DHB and 2,4,6-trihydroxy acetophenone (THAP) as matrix for MALDI-MS measurements retains the sensitivity of DHB for phosphopeptide analysis but adds the homogenous crystallization properties of THAP, enabling preparation of evenly distributed matrix surfaces on MALDI-MS anchor targets, a prerequisite for automated MALDI- MS analyses. Tripartite motif-containing protein 28 and stathmin are two examples for which successful phosphopeptide enrichment of either sodium dodecyl sulfate polyacrylamide gel electrophoresis or two-dimensional gel electrophoresis-separated proteins is shown. Finally, high resolution MALDI Fourier transform ion cyclotron resonance mass spectrometry after phosphopeptide enrichment suggests that chemical dephosphorylation may occur as a side reaction during basic elution of phosphopeptides bound to MOAC surfaces, suggesting that proteome-wide phosphopeptide analyses ought to be interpreted with caution. In contrast, in-depth analysis of phosphopeptide/non-phosphorylated peptide siblings may be used to estimate stability differences of phosphorylation sites in individual proteins, possibly adding valuable information on biological regulation processes.  相似文献   

4.
We utilized three different types of TiO2 nanoparticles (NPs) namely TiO2‐dopamine, TiO2‐CdS and bare TiO2 NPs as multifunctional nanoprobes for the rapid enrichment of phosphopeptides from tryptic digests of α‐ and β‐casein, milk and egg white using a simplified procedure in MALDI‐TOF‐MS. Surface‐modified TiO2 NPs serve as effective matrices for the analysis of peptides (gramicidin D, HW6, leucine‐enkephalin and methionine‐enkephalin) and proteins (cytochrome c and myoglobin) in MALDI‐TOF‐MS. In the surface‐modified TiO2 NPs‐based MALDI mass spectra of these analytes (phosphopetides, peptides and proteins), we found that TiO2‐dopamine and bare TiO2 NPs provided an efficient platform for the selective and rapid enrichment of phosphopeptides and TiO2‐CdS NPs efficiently acted as the matrix for background‐free detection of peptides and proteins with improved resolution in MALDI‐MS. We found that the upper detectable mass range is 17 000 Da using TiO2‐CdS NPs as the matrix. The approach is simple and straightforward for the rapid analysis of phosphopeptides, peptides and proteins by MALDI‐MS in proteome research.  相似文献   

5.
Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) is an excellent analytical technique for rapid analysis of a variety of molecules with straightforward sample pretreatment. The performance of MALDI‐TOF MS is largely dependent on matrix type, and the development of novel MALDI matrices has aroused wide interest. Herein, we devoted to seek more robust MALDI matrix for herbal saponins than previous reported, and ginsenoside Rb1, Re, and notoginsenoside R1 were used as model saponins. At the beginning of the present study, 2,5‐dihydroxybenzoic acid (DHB) was found to provide the highest intensity for saponins in four conventional MALDI matrices, yet the heterogeneous cocrystallization of DHB with analytes made signal acquisition somewhat “hit and miss.” Then, graphene oxide (GO) was proposed as an auxiliary matrix to improve the uniformity of DHB crystallization due to its monolayer structure and good dispersion, which could result in much better shot‐to‐shot and spot‐to‐spot reproducibility of saponin analysis. The satisfactory precision further demonstrated that minute quantities of GO (0.1 μg/spot) could greatly reduce the risk of instrument contamination caused by GO detachment from the MALDI target plate under vacuum. More importantly, the sensitivity and linearity of the standard curve for saponins were improved markedly by DHB‐GO composite matrix. Finally, the application of detecting the Rb1 in complex biological sample was exploited in rat plasma and proved it applicable for pharmacokinetic study quickly. This work not only opens a new field for applications of DHB‐GO in herbal saponin analysis but also offers new ideas for the development of composite matrices to improve MALDI MS performance.  相似文献   

6.
We report substantial in‐situ enrichment of phosphopeptides in peptide mixtures using titanium and zirconium dioxide‐coated matrix assisted laser desorption‐ionization (MALDI) plates prepared by recently reported ambient ion landing deposition technique. The technique was able to modify four common materials currently used for MALDI targets (stainless steel, aluminum, indium‐tin oxide glass and polymeric anchor chip). The structure of the deposited dioxide was investigated by electron microscopy, and different surfaces were compared and discussed in this study. Two standard proteins were used to test the enrichment capabilities of modified MALDI plates: casein and in‐vitro phosphorylated trehalase. The enrichment of casein tryptic digest resulted in identification of 20 phosphopeptides (including miscleavages). Trehalase was used as a suitable model of larger protein that provided more complex peptide mixture after the trypsin digestion. All four possible phosphorylation sites in trehalase were identified and up to seven phosphopetides were found (including methionine oxidations and miscleavages). Two different mass spectrometers, MALDI‐Fourier transform ion cyclotron resonance (FTICR) and MALDI‐time of flight, were used to detect the phosphopeptides from modified MALDI plates after the enrichment procedure. It was observed that the desorption‐ionization phenomena on the modified surfaces are not critically influenced by the parameters of the different MALDI ion sources (e.g. different pressure, different extraction voltages), and thus the presence of dioxide layer on the standard MALDI plate does not significantly interfere with the main MALDI processes. The detection of phosphopeptides after the enrichment could be done by both instruments. Desorption electrospray ionization coupled to the FTICR was also tested, but, unlike MALDI, it did not provide satisfactory results. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
张莹  陆豪杰  杨芃原 《中国化学》2008,26(10):1863-1869
本文建立了以磷酸铵盐为添加剂的基质新系统,增强了磷酸化肽在MALDI正离子模式下的离子化。系统地考察了不同的磷酸盐以及不同的盐浓度对磷酸化肽离子化效率的影响。考察了两种适合于磷酸化肽离子化的基质类型2,5-二羟基苯甲酸和2,4,6-三羟基苯乙酮。用2,5-二羟基苯甲酸作为基质时,当加入10 mM 磷酸氢二铵时,磷酸化蛋白质β-casein的磷酸肽 48FQ[pS]EEQQQTEDELQDK63的离子化效率可以增强5-8倍,当加入10 mM磷酸二氢胺时,磷酸肽的离子化效率可以增强3-4倍。用2,4,6-三羟基苯乙酮作为基质时,当加入5mM磷酸氢二铵时,磷酸化肽的离子化效率比文献报道的最有利于磷酸化肽离子化的基质体系增强了2倍。并探讨了铵根离子和磷酸根离子促进磷酸化肽在MALDI的正离子模式下离子化效率的机理。  相似文献   

8.
A facile two‐step method for preparing chitosan‐based immobilized metal ion affinity chromatography was developed. First, chitosan was phosphorylated by esterification with phosphoric acid, and then titanium was chelated onto the phosphorylated chitosan. The obtained chitosan‐based titanium immobilized metal ion affinity chromatography was ultrafine microparticles and had good dispersibility in acidic buffer. The selectivity and sensitivity were evaluated by phosphopeptide enrichment of mixtures of α‐casein and bovine serum albumin. The enriched peptides were analyzed by mass spectrum. Enrichment protocols were optimized and the optimum‐loading buffer was 80% acetonitrile with 1% trifluoroacetic acid. With α‐casein concentration as low as 2 pmol, 12 phosphopeptides were detected with considerably high intensity from the digest mixtures of α‐casein and bovine serum albumin with molar ratio of 1:200. The microparticles was also applied in real biological samples, 29 phosphoproteins containing 40 phosphorylated sites were identified from salt‐stressed Arabidopsis thaliana leaves.  相似文献   

9.
制作出一种新型的石蜡固化基质,并将其用于多肽以及蛋白质的MALDI-FTMS分析。在其制作过程中通过加热将固体石蜡融化并均匀涂敷在不锈钢靶板上,在不同温度下滴加基质溶液于石蜡涂层及不锈钢靶板上,分别制得不同形式的基质点。三维视频显微镜表征各基质点的表观形貌,并对比其上样前后的形貌变化。通过在不同基质点上分析多肽混合液以及牛血清白蛋白酶解液,以评价该固化基质的性能。MALDI-FTMS分析结果表明石蜡涂层内固化基质方法检测灵敏度明显优于其它几种状况下的样品分析方法。  相似文献   

10.
Fragmentation of different generations of poly(amidoamine) dendrimers was explored in five common MALDI matrices: 2,5-dihydroxybenzoic acid (DHB), 4-hydroxy-3-methoxycinnamic acid (FER), α-cyano-4-hydroxycinnamic acid (ACH), 2,4,6-trihydroxyacetophenone (THAP), and 3-hydroxypicolinic acid (HPA). Of these, DHB was the softest matrix and ACH produced significant fragment intensity already at MALDI threshold, FER and THAP being in between. HPA was not a convenient matrix for dendrimers and produced a specific fragmentation pattern. Fragmentation analysis was mainly concentrated on generation G1, which contains already all essential structural elements. Dendrimers showed complicated fragmentation behavior with multiple fragmentation channels in our MALDI experiments. The relative intensities of these channels depended selectively on choice of the matrix and showed dissimilar dependence on the laser pulse energy. This was attributed to different fragmentation mechanisms, due to different protonation pathways, occurring in the same MALDI plume. The fragmentation pathways were proposed for all observed fragmentation channels. All fragmentation sites of protonated ions were found to be directly attached to the protonation sites and the fragmentation was surplus charge driven in this sense. No charge remote fragmentation channels were detected. Cationized dendrimers showed higher stability than the protonated ions.  相似文献   

11.
The effect of matrix composition on signal suppression caused by a dominant compound under MALDI ionization was studied using the combinatorial TQTXT pentapeptide library as a model system. The peptide library is composed of 19 components with all proteinogenic amino acids except cysteine in position X. From these compounds, only the Arg peptide (TQTRT) was detected with sufficient intensity in the MALDI-TOF mass spectrum under typical MALDI conditions (CCA matrix). The analysis of a set of compounds utilized as different matrix components, additives and a cationizing agent revealed that the composition of the matrix is a critical point in signal suppression. Highly improved ion yields were achieved by using a CCA/DHB mixture as a matrix. The addition of K(+) as a cationizing agent to the CCA matrix resulted in MALDI-TOF mass spectra with relative ion intensities very similar to those obtained by electrospray ionization.  相似文献   

12.
The mass spectra of peptides obtained with different matrices were compared using a matrix-assisted laser desorption/ionization (MALDI) ion source and a multi-turn time-of-flight (TOF) mass spectrometer, MULTUM-IMG, which has been developed at Osaka University. Two types of solid matrices, alpha-cyano-4-hydroxycinnamic acid (CHCA) and 2,5-dihydroxybenzoic acid (DHB), and a liquid matrix made from a mixture of 3-aminoquinoline and CHCA were used. When measuring the peak signal intensity of human angiotensin II [M+H]+ from a fixed sample position, the liquid matrix produced a stable signal over 1000 laser shots, while the signal obtained with CHCA and DHB decayed after about 300 and 100 shots, respectively. Significant differences in the mass resolving power were not observed between the spectra obtained with the three matrices. Signal peak areas were measured as a function of the cycle number in a multi-turn ion trajectory, i.e., the total flight time over a millisecond time scale. For both [M+H]+ of human angiotensin II and bovine insulin, the decay of the signal peak area was the most significant with CHCA, while that measured with DHB was the smallest. The results of the mean initial ion velocity measurements suggested that the extent of metastable decomposition of the analyte ions increased in order of DHB, the liquid matrix, and CHCA, which is consistent with the difference in the decay of the signal peak area as the total flight time increased.  相似文献   

13.
Owing to its broad biological significance, the large-scale analysis of protein phosphorylation is more and more getting into the focus of proteomic research. Thousands of phosphopeptides can nowadays be identified using state-of-the-art tandem mass spectrometers in conjunction with sequence database searching, but localizing the phosphate group to a particular amino acid in the peptide sequence is often still difficult. Using 180 individually synthesized phosphopeptides with precisely known phosphorylation sites (p-sites), we have assessed the merits of the Mascot Delta Score (MD score) for the assignment of phosphorylation sites from tandem mass spectra (MS/MS) generated on four different matrix-assisted laser desorption ionization (MALDI) mass spectrometers including tandem time-of-flight (TOF/TOF), quadrupole time-of-flight, and ion trap mass analyzers. The results show that phosphorylation site identification is generally possible with false localization rates of about 10%. However, a comparison to previous work also revealed that phosphorylation site determination by MALDI MS/MS is less accurate than by ESI-MS/MS particularly if several and/or adjacent possible phosphorylation acceptor sites exist in a peptide sequence. We are making the tandem MS spectra and phosphopeptide collection available to the community so that scientists may adapt the MD scores reported here to their analytical environment and so that informatics developers may integrate the MD score into proteomic data analysis pipelines.  相似文献   

14.
Negative ion production from peptides and proteins was investigated by matrix‐assisted laser desorption/ionization time‐of‐flight (MALDI‐TOF) mass spectrometry. Although most research on peptide and protein identification with ionization by MALDI has involved the detection of positive ions, for some acidic peptides protonated molecules are not easily formed because the side chains of acidic residues are more likely to lose a proton and form a deprotonated species. After investigating more than 30 peptides and proteins in both positive and negative ion modes, [M–H] ions were detected in the negative ion mode for all peptides and proteins although the matrix used was 2,5‐dihydroxybenzoic acid (DHB), which is a good proton donor and favors the positive ion mode production of [M+H]+ ions. Even for highly basic peptides without an acidic site, such as myosin kinase inhibiting peptide and substance P, good negative ion signals were observed. Conversely, gastrin I (1‐14), a peptide without a highly basic site, will form positive ions. In addition, spectra obtained in the negative ion mode are usually cleaner due to absence of alkali metal adducts. This can be useful during precursor ion isolation for MS/MS studies. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

15.
Titanium dioxide metal oxide affinity chromatography (TiO2‐MOAC) is widely regarded as being more selective than immobilized metal‐ion affinity chromatography (IMAC) for phosphopeptide enrichment. However, the widespread application of TiO2‐MOAC to biological samples is hampered by conflicting reports as to which experimental conditions are optimal. We have evaluated the performance of TiO2‐MOAC under a wide range of loading and elution conditions. Loading and stringent washing of peptides with strongly acidic solutions ensured highly selective enrichment for phosphopeptides, with minimal carryover of non‐phosphorylated peptides. Contrary to previous reports, the addition of glycolic acid to the loading solution was found to reduce specificity towards phosphopeptides. Base elution in ammonium hydroxide or ammonium phosphate provided optimal specificity and recovery of phosphorylated peptides. In contrast, elution with phosphoric acid gave incomplete recovery of phosphopeptides, whereas inclusion of 2,5‐dihydroxybenzoic acid in the eluant introduced a bias against the recovery of multiply phosphorylated peptides. TiO2‐MOAC was also found to be intolerant of many reagents commonly used as phosphatase inhibitors during protein purification. However, TiO2‐MOAC showed higher specificity than immobilized gallium (Ga3+), immobilized iron (Fe3+), or zirconium dioxide (ZrO2) affinity chromatography for phosphopeptide enrichment. Matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) was more effective in detecting larger, multiply phosphorylated peptides than liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS), which was more efficient for smaller, singly phosphorylated peptides. Copyright © 2009 Crown in the right of Canada. Published by John Wiley & Sons, Ltd.  相似文献   

16.
In this study, a new strategy named two‐step IMAC is demonstrated as a novel prelude to MS analysis of phosphoproteome by increasing the enrichment factor of phosphoproteins/phosphopeptides from a protein mixture. In this method, the first IMAC was performed at the protein level to extract the minute amount of phosphoproteins present in the sample. During this step, nonphosphoproteins and other undesired chemicals or inhibitors were excluded. After tryptic digestion, the second IMAC was performed at the peptide level to enrich phosphopeptides present in the tryptic digest, and the eluent from the second IMAC was analyzed by MALDI‐MS. It is particularly noticeable that the eluent from the first IMAC can be directly digested by trypsin without buffer exchange. Our results revealed that β‐casein that was spiked in a protein mixture can be successfully extracted by the first IMAC at a concentration of less than 1–3%, and the two phosphopeptides of β‐casein with single and four phosphorylation sites, respectively, can be captured by the second IMAC. It was found that the two‐step IMAC method could significantly reduce non‐specific bindings from unwanted proteins and greatly enhance the MALDI‐MS signal of phosphopeptide ions compared to the typical one‐step IMAC, by which only IMAC at the peptide level was performed. Two‐step IMAC was also found to tolerate a greater amount and a greater concentration range of proteins than one‐step IMAC, which is especially important when analyzing complicated unknown samples. Furthermore, the MS signal of phosphopeptide ions did not appear to be degraded by the presence of biological matrixes, such as the cell lysate in which the β‐casein was spiked in.  相似文献   

17.
Electron capture dissociation of singly and multiply phosphorylated peptides   总被引:12,自引:0,他引:12  
Analysis of phosphotyrosine and phosphoserine containing peptides by nano-electrospray Fourier transform ion cyclotron resonance (FTICR) mass spectrometry established electron capture dissociation (ECD) as a viable method for phosphopeptide sequencing. In general, ECD spectra of synthetic and native phosphopeptides appeared less complex than conventional collision activated dissociation (CAD) mass spectra of these species. ECD of multiply protonated phosphopeptide ions generated mainly c- and z(.)-type peptide fragment ion series. No loss of water, phosphate groups or phosphoric acid from intact phosphopeptide ions nor from the c and z(.) fragment ion products was observed in the ECD spectra. ECD enabled complete or near-complete amino acid sequencing of phosphopeptides for the assignment of up to four phosphorylation sites in peptides in the mass range 1400 to 3500 Da. Nano-scale Fe(III)-affinity chromatography combined with nano-electrospray FTMS/ECD facilitated phosphopeptide analysis and amino acid sequencing from crude proteolytic peptide mixtures.  相似文献   

18.
Cinnamic acid derivatives, particularly α‐cyano‐4‐hydroxycinnamic acid (E‐α‐cyano‐4‐hydroxycinnamic acid or (E)‐2‐cyano‐3‐(4‐hydroxyphenyl)prop‐2‐enoate; CHCA), have been extensively used especially for protein and peptide analysis. Together with the introduction of ionic liquid MALDI matrix (ILM) started the study of applications of IL prepared with CHCA and a counter organic base (ie, aliphatic amines) in which CHCA moiety is the chromophore responsible of UV‐laser absorption. Despite the extensive studies of norharmane (9H‐pyrido[3,4‐b]indole; nHo) applications as matrix and its peculiar basic properties in the ground and electronic excited state, nHo containing ILM was never tested in MALDI‐MS experiments. This pyrido‐indole compound was introduced as MALDI matrix 22 years ago for different applications including low molecular weight (LMW) carbohydrates (neutral, acidic, and basic carbohydrates). These facts encouraged us to use it as a base, for the first time, for ILM preparation. As a rational design of new IL MALDI matrices, E‐α‐cyanocinnamic acid.nHo and E‐cinnamic acid.nHo were prepared and their properties as matrices studied. Their performance was compared with that of (a) the corresponding IL prepared with butylamine as basic component, (b) the corresponding crystalline E‐α‐cyanocinnamic and E‐cinnamic acid, and (c) the classical crystalline matrices (2,5‐dihydroxybenzoic acid, DHB; nHo) used in the analysis of neutral/sulfated carbohydrates. The IL DHB.nHo was tested, too. Herein, we demonstrate the outstanding performance for the IL CHCA.nHo for LMW carbohydrate in positive and negative ion mode (linear and reflectron modes). Sulfated oligosaccharides were detected in negative ion mode, and although the dissociation of sulfate groups was not completely suppressed the relative intensity (RI) of [M ? Na]? peak was quite high. Additionally, to better understand the quite different performance of each IL tested as matrix, the physical and morphological properties in solid state were studied (optical image; MS image).  相似文献   

19.
Two orders of magnitude matrix-assisted laser desorption/ionization (MALDI) signal enhancement of phosphopeptides has been achieved by picolinamidination of N-terminal amine group and ε-amine group of lysine residues. Due to the presence of picolinamidination tag at the N-terminal amine of peptides, MS/MS spectra with a strong b-ion series was obtained, which greatly facilitated sequencing and identification of the phosphorylation site. Phosphorylation site of a phosphopeptide could be identified from MALDI TOF/TOF spectrum obtained from a tryptic or a chymotryptic phosphopeptide, which was not even detected in the positive ion mode, without signal enhancement by picolinamidination, due to the negative charge of the phosphate group in the presence of other peptides.  相似文献   

20.
The specific matrix used in matrix‐assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) can have an effect on the molecules ionized from a tissue sample. The sensitivity for distinct classes of biomolecules can vary when employing different MALDI matrices. Here, we compare the intensities of various lipid subclasses measured by Fourier transform ion cyclotron resonance (FT‐ICR) IMS of murine liver tissue when using 9‐aminoacridine (9AA), 5‐chloro‐2‐mercaptobenzothiazole (CMBT), 1,5‐diaminonaphthalene (DAN), 2,5‐Dihydroxyacetophenone (DHA), and 2,5‐dihydroxybenzoic acid (DHB). Principal component analysis and receiver operating characteristic curve analysis revealed significant matrix effects on the relative signal intensities observed for different lipid subclasses and adducts. Comparison of spectral profiles and quantitative assessment of the number and intensity of species from each lipid subclass showed that each matrix produces unique lipid signals. In positive ion mode, matrix application methods played a role in the MALDI analysis for different cationic species. Comparisons of different methods for the application of DHA showed a significant increase in the intensity of sodiated and potassiated analytes when using an aerosol sprayer. In negative ion mode, lipid profiles generated using DAN were significantly different than all other matrices tested. This difference was found to be driven by modification of phosphatidylcholines during ionization that enables them to be detected in negative ion mode. These modified phosphatidylcholines are isomeric with common phosphatidylethanolamines confounding MALDI IMS analysis when using DAN. These results show an experimental basis of MALDI analyses when analyzing lipids from tissue and allow for more informed selection of MALDI matrices when performing lipid IMS experiments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号