首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Doping control analysis of performance‐enhancing peptides in urine represents a challenging requirement in modern sports drug testing. Low dosing, effective metabolism and short half‐life lead to target concentrations in the low fmol/mL range in urine. Synthetic adrenocorticotropic hormone (1‐24, Syn‐ACTH‐en) shares all these characteristics and improved analytical performance is required for its sufficient determination by means of liquid chromatography/tandem mass spectrometry (LC/MS/MS). The desired effects for cheating sportsmen are mainly due to enhanced release of corticosteroids as well as androgenic steroids into the circulation after systemic administration of the drug. Immunoaffinity purification with coated magnetic beads and subsequent liquid chromatography with nano‐ultra‐performance liquid chromatography (UPLC) coupled to tandem mass spectrometry (high resolution/high mass accuracy) of Synacthen from urinary specimens is described in the present study. The general proof of principle was obtained by analysis of excretion study urine samples and validation was performed with focus on the limit of detection (3 pg/mL), linearity, precision (<20%), recovery (~30%), robustness, specificity and stability. For all experiments, the ACTH fragment 1‐17 was used as the internal standard. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
Steroid hormones play a critical role in maintaining the homeostasis of human metabolism. Urine as a noninvasive sample has been extensively used in clinical diagnosis for hormones homeostasis. In this study, the simultaneous characterization of fourteen hormones in urine was performed based on ultra‐high‐performance liquid chromatography/electrospray ionization tandem mass spectrometry (UPHLC/ESI(+)‐MS/MS) with multiple reaction monitoring in the positive ionization mode. The target hormones were cortisone, cortisol, 11‐deoxycortisol, aldosterone, corticosterone, 11‐deoxycorticosterone, progesterone, 17‐OH‐progesterone, pregnenolone, estrone, estradiol, estriol, testosterone and dehydreopiandrosterone. β‐Glucuronidase/sulfatase deconjugation and liquid–liquid extraction (LLE) were conducted for the determination of urinary hormones (free + conjugated forms). The limits of detection (LODs) ranged from 0.2 ng/mL (11‐deoxycortisol and testosterone) to 1 ng/mL (cortisone). The extraction recovery of the targeted compounds ranged from 87% to 127%, indicating sufficient extraction efficiency for the LLE process. Intraday precision was below 10% and the accuracy ranged from 84% to 122%. The profiling analysis of hormones in urine samples helps to understand the metabolic state of biological systems and can be employed as a diagnostic tool in diseases developed by endocrine‐disrupted systems.  相似文献   

3.
An ultra‐high‐performance liquid chromatography/electrospray ionisation tandem mass spectrometry system is described for the separation and characterisation of uroporphyrinogen, heptacarboxylic acid porphyrinogen, hexacarboxylic acid porphyrinogen, pentacarboxylic acid porphyrinogen and coproporphyrinogen. The separation was carried out on a 100 mm × 2.1 mm Thermo‐Hypersil BDS column (2.4 µm average particle size) by gradient elution with a mixture of acetonitrile, methanol and 1 mol/L aqueous ammonium acetate buffer, pH 5.16, as eluent. The fragmentation pattern of each compound was established by collision‐induced dissociation tandem mass spectrometry. The most characteristic fragmentation was ring opening at one of the four methylene bridges of the protonated porphyrinogen molecule followed by further cleavages of methylene bridges linking the four pyrrole rings at various points to give product ions with methylenepyrrolenine, methylene‐dipyrrolenine and methylene‐tripyrrolenine structures. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
A simple and reproducible UPLC‐MS/MS method for the determination of itraconazole (ITZ) and its photodegradation products formed during exposure to UV‐A radiation was developed. Chromatographic separations were carried out using an Acquity UPLC BEH C18 column (2.1 × 100 mm, 1.7 μm particle size). The column was maintained at 40°C, and eluted under gradient conditions from 100% to 50% of eluent A over 13 min, at a flow rate of 0.3 mL min?1. Eluent A was 0.1% (v/v) formic acid in water; eluent B was 0.1% (v/v) formic acid in acetonitrile. The linear regression analysis for the calibration curve showed a good linear correlation over the concentration range 0.0066–0.15 mg mL?1 with determination coefficient > 0.99. The activities of some photocatalysts during degradation process of ITZ were compared. It was found that indirect photodegradation of ITZ was more effective than direct photolysis. Under our experimental conditions the photodegradation rate constant depended on the applied catalysts with catalytic activity decreasing in the following pattern: FeCl3 > TiO2/FeCl3 > TiO2. The kinetic analysis of the photodegradation data revealed that the degradation of the ITZ follows first‐order kinetics. The photodegradation products of ITZ were identified, and their fragmentation pathways, derived from MS/MS data, were proposed. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

5.
A novel method for the biological monitoring of benzene‐exposed workers has been developed through ultra‐performance liquid chromatography coupled to tandem mass spectrometry. The method uses trans,trans‐muconic acid in urine as the benzene‐exposure biomarker. The method was developed using a triple quadrupole mass spectrometer with enough sensitivity to facilitate diluting and injecting the urine samples directly, rather than performing a solid‐phase extraction procedure as is common in the available protocols. Moreover, compared with a conventional high‐pressure liquid chromatography system, the separation power provided by the ultra‐performance liquid chromatography system allows a 10‐fold reduction in run time. The method was adjusted to a dynamic range of between 198.9 and 4916.7 µg/L to cover the biological exposure index of trans,trans‐muconic acid in urine. Also, the method demonstrated intra‐day and inter‐day precision at 98%, and accuracy within an acceptable range of 101 ± 8%. The method has been used to quantify various types of urine samples, such as workers' urine and inter‐laboratory proficiency tests. Depending on the sample, the quantified levels ranged from less than the limit of quantitation to 3836.7 µg/L. No levels exceeding the calibration range were detected in the urine of workers, and the reported concentrations in urine for the proficiency tests were, as expected, based on known values. Moreover, the new method using sample dilution and faster chromatographic run was more effective, facilitating fast communication of results, as needed, to decision‐makers. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
7.
Dendrobine, considered as the major active alkaloid compound, has been used for the quality control and discrimination of Dendrobium which is documented in the Chinese Pharmacopoeia. In this work, a sensitive and simple ultra‐performance liquid chromatography tandem mass spectrometry (UPLC‐MS/MS) method for determination of dendrobine in rat plasma is developed. After addition of caulophyline as an internal standard (IS), protein precipitation by acetonitrile–methanol (9:1, v/v) was used to prepare samples. Chromatographic separation was achieved on a UPLC BEH C18 (2.1 ×100 mm, 1.7 µm) column with acetonitrile and 0.1% formic acid as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring mode was used for quantification using target fragment ions m/z 264.2 → 70.0 for dendrobine and m/z 205.1 → 58.0 for IS. Calibration plots were linear throughout the range 2–1000 ng/mL for dendrobine in rat plasma. The RSDs of intra‐day and inter‐day precision were both <13%. The accuracy of the method was between 95.4 and 103.9%. The method was successfully applied to pharmacokinetic study of dendrobine after intravenous administration. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
Over the past years, LC–MS‐based approaches have gained a growing interest in food analysis by using different platforms and methodologies. In particular, enhanced selectivity and sensitivity of multiple reaction monitoring (MRM) scan function offer powerful capabilities in detecting and quantifying specific analytes within complex mixtures such as food matrices. The MRM approach, traditionally applied in biomedical research, is particularly suitable for the detection of food adulteration and for the verification of authenticity to assure food safety and quality, both recognized as top priorities by the European Union Commission. Increasingly stringent legislation ensure products safety along every step ‘from farm to fork’, especially for traditional foods designed with the Protected Designation of Origin certification. Therefore, there is a growing demand of new methodologies for defining food authenticity in order to preserve their unique traits against frauds. In this work, an ultra performance liquid chromatopgraphy‐electrospray ionization‐tandem mass spectrometry (MS/MS) methodology based on MRM has been developed for the sensitive and selective detection of buffalo mozzarella adulteration. The targeted quantitative analysis was performed by monitoring specific transitions of the phosphorylated β‐casein f33‐48 peptide, identified as a novel species‐specific proteotypic marker. The high sensitivity of MRM‐based MS and the wide dynamic range of triple quadrupole spectrometers have proved to be a valuable tool for the analysis of food matrices such as dairy products, thus offering new opportunities for monitoring food quality and adulterations. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
A reliable and sensitive method was developed for determination of nitroimidazoles in porcine urine. Sample preparation involves an extraction with ethyl acetate, followed by a solid-phase extraction cleanup step. The final extract is injected into the liquid chromatography/tandem mass spectrometry system in the positive-ion electrospray ionization mode. A C8 column with water and acetonitrile as the mobile phase is used for chromatographic separation under gradient conditions. Overall average recoveries ranged from 83 to 107%. The limits of detection ranged from 0.03 to 0.05 ng/mL, and the limits of quantitation, from 0.1 to 0.2 ng/mL.  相似文献   

10.
11.
饲料样品经1%三氯乙酸-二甲基亚砜提取,Waters Oasis MCX柱净化,超高效液相色谱分离,最终采用电喷雾串联四极杆质谱进行检测。结果表明,三聚氰胺在饲料中的含量范围为10~5000 μg/kg时,线性关系良好(r>0.99)。在10~100 μg/kg 的添加水平范围内的平均回收率为83%~94%,相对标准偏差为4.2%~6.5%。该方法的检出限为10 μg/kg。  相似文献   

12.
13.
采用超高效液相色谱-串联质谱(UPLC-MS/MS)联用技术,建立了对人尿液中12种全氟有机化合物(PFCs)的分析方法。首先在尿液样品中加入相应的同位素内标,以2%(体积分数)甲酸甲醇溶液超声萃取、离心后,将提取液用弱阴离子交换固相萃取柱净化,采用UPLC-MS/MS测定,内标法定量。12种目标化合物在0.05~50 μg/L质量浓度范围内线性良好,相关系数(r)均大于0.992,检出限在0.44~3.47 ng/L之间。在20、100、500 ng/L添加水平下,平均回收率范围为80.3%~116.2%,相对标准偏差(n=6)在5.5%~13.8%之间。该方法灵敏度高、重现性好、回收率高、操作简单,适合人尿液中PFCs的测定。  相似文献   

14.
15.
In early 2007 it was determined that the compound melamine, suspected of having been involved in the deaths of numerous pets, had been fed to hogs intended for human consumption. This report describes a method for the analysis of melamine in porcine muscle tissue using solid-phase extraction (SPE) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). Melamine was extracted in 50% acetonitrile in water. Homogenates were centrifuged and supernatants were acidified and washed with methylene chloride. The aqueous extracts were cleaned up using mixed-mode C8/strong cation exchange SPE and then concentrated, fortified with a stable isotope-labeled analog of melamine, and analyzed by HPLC/MS/MS. Gradient HPLC separation was performed using an ether-linked phenyl column with ammonium acetate/acetic acid and acetonitrile as the mobile phase. Multiple reaction monitoring (MRM) mode of two precursor-product ion transitions for melamine and one for the internal standard was used. A five point calibration curve ranging from 50 to 2000 ng/mL of melamine in solvent was used to establish instrument response. The method was validated by analysis of seven replicate porcine muscle tissue samples fortified with 10 ng/g of melamine. The mean recovery for the seven replicates was 83% with 6.5% relative standard deviation and the calculated method detection limit was 1.7 ng/g.  相似文献   

16.
17.
18.
To characterize the preclinical plasma pharmacokinetics of entrectinib, a reproducible and precise assay is necessary. In this study, we developed and validated a simple ultra‐performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) method for the measurement of entrectinib using carbamazepine as the internal standard in rat plasma. Sample preparation was a simple protein precipitation with acetonitrile, then entrectinib was eluted on an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7 μm) using a gradient elution with a mobile phase composed of acetonitrile (A) and 0.1% formic acid in water (B). Detection was achieved using multiple‐reaction monitoring in positive ion electrospray ionization mode. The method showed good linearity over the concentration range of 1–250 ng/mL (r2 > 0.9951). The intra‐ and inter‐day precision was determined with the values of 6.3–12.9 and 2.6–6.9%, respectively, and accuracy values of 0.5–11.6%. Matrix effect, extraction recovery, and stability data all met the acceptance criteria of US Food and Drug Administration guidelines for bioanalytical method validation. The method was successfully applied to a pharmacokinetic study. In this study, we developed the complete validated method for the quantification of entrectinib in rat plasma.  相似文献   

19.
Thyreostatic compounds could be illegally administered to animals in order to obtain a weight gain due to a higher retention of water in the edible tissue and the gastro-intestinal tract. In the European Union their use for animal production is banned since 1981. Recently a highly sensitive method exploiting the determination of thyreostats with 3-iodobenzylbromide prior to purification to determine thyreostats in urine and other matrices was reported. For the first time, the UPLC instrumentation was used to separate the 3-iodobenzyl derivatives of various thyreostats. The deuterated internal standards tapazole-d3 and propylthiouracil-d5 were for the first time used for the quantification of tapazole, thiouracil, methylthiouracil, propylthiouracil, phenylthiouracil and mercaptobenzimidazole. The confirmative quantitative liquid chromatographic tandem mass spectrometric (LC–MS/MS) method was validated according to Commission Decision 2002/657/EC. The decision limit (CCα) and the detection capability (CCβ) were found to be for all compounds below the recommended value of 10 μg kg−1.  相似文献   

20.
In conjunction with an AOAC Task Group on dietary supplements, a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was validated for measurement of 6 major alkaloids in raw ephedra sinica herb, ephedra extracts, ephedra tablets, complex dietary supplements containing ephedra, and a high-protein drink mix containing ephedra. The amount of ephedrine-type alkaloids present was determined by LC with mass selective detection. Six replicates of each matrix were analyzed on 3 separate occasions. The presence of 6 ephedrine-type alkaloids was detected at a level > 0.5 microg/g based on a 0.5 g sample. The standard curve range for this assay is from 0.02 to 1.0 microg/mL. Appropriate dilutions covered a wide range of specific alkaloid concentrations. The calibration curves for all 6 analytes had correlation coefficients > 0.995.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号