首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 578 毫秒
1.
The aim of this study was to establish and validate a rapid, selective and reliable ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) for simultaneous quantitations of morin and morusin, and to investigate their pharmacokinetics difference between normal and diabetic rats after oral administration. Plasma samples were pretreated via protein precipitation with acetonitrile. Genkwanin was used as internal standard (IS). Analytes and IS were separated on a Thermo Hypersil Gold C18 column (50 × 4.6 mm, 3 μm) using gradient elution. The mobile phase consisted of acetonitrile and 0.1% formic acid in water at a flow rate of 0.5 mL/min. Mass spectrometry detection was carried out by means of negative electrospray ionization source and multipe‐reaction monitoring mode. The transitions of m/z 300.9 → 151.2 for morin, m/z 419.2 → 297.1 for morusin and m/z 283.1 → 268.2 for IS were chosen for quantification. Calibration curves were linear in the range of 1.01–504.2 ng/mL (r2 ≥ 0.99) for morin and 1.02–522.3 ng/mL (r2 ≥ 0.99) for morusin. The lower limit of quantification was 1.02 ng/mL for morin and 1.05 ng/mL for morusin. The extraction recovery was >85.1% for each analyte. No obvious matrix effect was observed under the present UPLC–MS/MS conditions during all of the bioanalysis. The stability study demonstrated that morin and morusin remained stable during the whole analytical procedure. The method was successfully applied to support the pharmacokinetic comparisons of morin and morusin between normal and diabetic rats.  相似文献   

2.
A simple and reproducible bioanalytical method for the determination of flecainide in human plasma was developed and validated using an ultra‐performance liquid chromatography with tandem mass spectrometry (UPLC‐MS/MS) to obtain higher sensitivity than the current available methods. After simple protein precipitation, flecainide and a stable isotope‐labeled internal standard (IS) were chromatographed on an Acquity UPLC BEH C18 column (2.1 × 100 mm, 1.7 µm) with isocratic elution of mobile phase consisting of 45% methanol containing 0.1% formic acid at a flow rate 0.25 mL/min. Detection was performed in positive electrospray ionization by monitoring the selected ion transitions at m/z 415.4/301.1 for flecainide and m/z 419.4/305.1 for the IS. The method was validated according to current bioanalytical method validation guidelines. The calibration standard curve was linear from 2.5 to 1000 ng/mL using 0.1 mL of plasma. No significant interferences were detected in blank human plasma. Accuracy and precision in the intra‐ and inter‐batch reproducibility study were within acceptance criteria. Neither hemolysis effects nor matrix effects were observed. The UPLC‐MS/MS method developed was successfully applied to determine plasma flecainide concentrations to support clinical studies and incurred sample reanalysis also ensured the reproducibility of the method. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

3.
A sensitive, selective and high‐throughput UPLC‐MS/MS method was developed and validated for the determination of a novel c‐Met tyrosine kinase inhibitor, QBH‐196, in rat plasma. QBH‐196 and its analog BH357 (IS) were extracted from rat plasma using a mixture of dichloromethane and N‐hexane (2:3, v/v). The chromatographic separation was carried out on Phenomenex C18 column (50 × 2.1 mm, 2.6 µm particle size) with a gradient mobile phase of methanol (A) and water containing 0.05% formic acid (B) at a flow rate of 0.2 mL/min. The assay was performed by positive electrospray ionization in multiple reaction monitoring mode using transitions of m/z 622.68 → 140.41 for QBH‐196 and m/z 591.19 →126.21 for the IS, respectively. Good linearity was obtained over the concentration range of 8.0–4000 ng/mL (r2 > 0.99) for QBH‐196 and the lower limit of quantification was 8.0 ng/mL in rat plasma. Validations of the method, including its sensitivity, extraction recovery, matrix effect, intra‐ and inter‐day precision, accuracy and stability, were all within acceptable limits. The established method was successfully applied to determine absolute oral bioavailability of QBH‐196 in rats for the first time. The mean oral absolute bioavailability of QBH‐196 was found to be about 40.8% and the elimination half‐life was 40.0 ± 13.1 h. This result suggested that QBH‐196 exhibits good oral absorption in vivo, which is very important for the further development of QBH‐196 as a new oral anticancer drug. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

4.
A simple, rapid and sensitive ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method has been developed and validated for the determination of alosetron (ALO) in human plasma. The assay method involved solid‐phase extraction of ALO and ALO 13C‐d3 as internal standard (IS) on a LichroSep DVB‐HL (30 mg, 1 cm3) cartridge. The chromatography was performed on an Acquity UPLC BEH C18 (50 × 2.1 mm, 1.7 µm) column using acetonitrile and 2.0 mm ammonium formate, pH 3.0 adjusted with 0.1% formic acid (80:20, v/v) as the mobile phase in an isocratic mode. For quantitative analysis, the multiple reaction monitoring transitions studied were m/z 295.1/201.0 for ALO and m/z 299.1/205.1 for IS in the positive ionization mode. The method was validated over a concentration range of 0.01–10.0 ng/mL for ALO. Post‐column infusion experiment showed no positive or negative peaks in the elution range of the analyte and IS after injection of extracted blank plasma. The extent of ion‐suppression/enhancement, expressed as IS‐normalized matrix factor, varied from 0.96 to 1.04. The assay recovery was within 97–103% for ALO and IS. The method was successfully applied to support a bioequivalence study of 1.0 mg alosetron tablets in 28 healthy Indian male and female subjects. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
A liquid chromatographic mass spectrometric (LC‐MS) assay has been developed for cyclosporine A (CyA) in rat plasma using amiodarone as internal standard (IS). Rat plasma (100 µL) containing drug and IS were extracted using liquid–liquid extraction with 4 mL of 95:5 ether:methanol. After evaporation of the organic layer the residue was reconstituted with 500 µL of water. Then the aqueous layer was transferred to LC‐MS sample vials. A 10 µL volume was injected. The analysis was performed on a C8 column 3.5 µm (2.1 × 50 mm) heated to 60°C with a mobile phase consisting of acetonitrile:methanol:0.2% NH4OH (60:20:20) at an isocratic flow‐rate of 0.2 mL/min. The ions used for quantitation of CyA and IS were m/z 1202.8 and 645.9, with retention times of 3.35 and 4.72 min, respectively. Linear relationships (r2 > 0.99) were achieved between plasma or blood concentration and peak height ratios (drug:IS) over the concentration range 50–5000 ng/mL. The CV% and mean error were <19%. Based on validation data, the lower limit of quantification for the assay was 50 ng/mL. The reported assay method displayed high measures of linearity, sensitivity, reliability and precision, allowing its applicability in pharmacokinetic studies in rat. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
A precise, high‐throughput and sensitive ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method has been developed for the determination of fluorochloridone (FLC) in rat plasma. The extraction of analytes from plasma samples was carried out by protein precipitation procedure using acetonitrile prior to UPLC‐MS/MS analysis. Verapamil was proved as a proper internal standard (IS) among many candidates. The chromatographic separation based on UPLC was well optimized. Multiple reaction monitoring in positive electrospray ionization was used with the optimized MS transitions at: m/z 312.0 → 292.0 for FLC and m/z 456.4 → 165.2 for IS. This method was well validated with good linear response (r2 > 0.998) observed over the investigated range of 3–3000 ng/mL and with satisfactory stability. This method was also characterized with adequate intra‐ and inter‐day precision and accuracy (within 12%) in the quality control samples, and with high selectivity and less matrix effect observed. Total running time was only 1.5 min. This method has been successfully applied to a pilot FLC pharmacokinetic study after oral administration. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

7.
A rapid, sensitive and specific method using liquid chromatography with tandem mass spectrometric detection (LC‐MS) was developed for the analysis of sauchinone in rat plasma. Di‐O‐methyltetrahydrofuriguaiacin B was used as internal standard (IS). Analytes were extracted from rat plasma by liquid–liquid extraction using ethyl acetate. A 2.1 mm i.d. × 150 mm, 5 µm, Agilent Zorbax SB‐C18 column was used to perform the chromatographic analysis. The mobile phase was methanol–deionized water (80:20, v/v). The chromatographic run time was 7 min per injection and the flow‐rate was 0.2 mL/min. The tandem mass spectrometric detection mode was achieved with electrospray ionization interface in positive‐ion mode (ESI+). The m/z ratios [M + Na]+, m/z 379.4 for sauchinone and m/z 395.4 for IS were recorded simultaneously. Calibration curve were linear over the range of 0.01–5 µg/mL. The lowest limit of quantification was 0.01 µg/mL. The intra‐day and inter‐day precision and accuracy of the quality control samples were 2.94–9.42% and 95.79–108.05%, respectively. The matrix effect was 64.20–67.34% and the extraction recovery was 93.28–95.98%. This method was simple and sensitive enough to be used in pharmacokinetic research for determination of sauchinone in rat plasma. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

8.
A rapid and sensitive ultra‐high performance liquid chromatography–mass spectrometry (UPLC‐MS/MS) method was developed and validated for the quantification of 10 major active constituents in rat urine after oral administration of Shensong Yangxin Capsule (SSYX) using diazepam as an internal standard (IS). The urine samples were pretreated and extracted by solid‐phase extraction prior to UPLC. Chromatographic separation was achieved on a Waters C18 (2.1 × 50 mm, 1.7 µm) column using a gradient elution program with 0.1% formic acid aqueous solution and acetonitrile at a flow rate of 0.4 mL/min. Detection and quantitation were accomplished by a hybrid quadrupole mass spectrometer using electrospray ionization source and multiple reaction monitoring in the positive ionization mode. The mass transition ion‐pairs (m/z) for quantitation were all optimized and the total run time was 4.50 min. The specificity, linearity, accuracy, precision, recovery, matrix effect and stabilities were all validated for the analytes in urine samples. The validation results indicated that this method was simple, rapid, specific and reliable. The proposed method was successfully applied to investigate the urinary excretion kinetics of 10 compounds in rat after oral administration of SSYX. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
Dendrobine, considered as the major active alkaloid compound, has been used for the quality control and discrimination of Dendrobium which is documented in the Chinese Pharmacopoeia. In this work, a sensitive and simple ultra‐performance liquid chromatography tandem mass spectrometry (UPLC‐MS/MS) method for determination of dendrobine in rat plasma is developed. After addition of caulophyline as an internal standard (IS), protein precipitation by acetonitrile–methanol (9:1, v/v) was used to prepare samples. Chromatographic separation was achieved on a UPLC BEH C18 (2.1 ×100 mm, 1.7 µm) column with acetonitrile and 0.1% formic acid as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring mode was used for quantification using target fragment ions m/z 264.2 → 70.0 for dendrobine and m/z 205.1 → 58.0 for IS. Calibration plots were linear throughout the range 2–1000 ng/mL for dendrobine in rat plasma. The RSDs of intra‐day and inter‐day precision were both <13%. The accuracy of the method was between 95.4 and 103.9%. The method was successfully applied to pharmacokinetic study of dendrobine after intravenous administration. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
In this work, a sensitive and selective ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method for determination of hupehenine in rat plasma was developed and validated. After addition of imperialine as an internal standard (IS), protein precipitation by acetonitrile–methanol (9:1, v/v) was used to prepare samples. Chromatographic separation was achieved on a UPLC BEH C18 column (2.1 × 100 mm, 1.7 µm) with 0.1% formic acid and acetonitrile as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring mode was used for quantification using target fragment ions m/z 416.3 → 98.0 for hupehenine, and m/z 430.3 → 138.2 for IS. Calibration plots were linear throughout the range 2–2000 ng/mL for hupehenine in rat plasma. Mean recoveries of hupehenine in rat plasma ranged from 92.5 to 97.3%. Relative standard deviations of intra‐day and inter‐day precision were both <6%. The accuracy of the method was between 92.7 and 107.4%. The method was successfully applied to a pharmacokinetic study of hupehenine after either oral or intravenous administration. For the first time, the bioavailability of hupehenine was reported as 13.4%. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
In this study, a new LC‐ESI‐MS/MS‐based method was validated for the quantitation of hemslecin A in rhesus monkey plasma using otophylloside A as internal standard (IS). Hemslecin A and the IS were extracted from rhesus monkey plasma using liquid–liquid extraction as the sample clean‐up procedure, and were subjected to chromatography on a Phenomenex Luna CN column (150 × 2.0 mm, 3.0 µm) with the mobile phase consisting of methanol and 0.02 mol/mL ammonium acetate (55:45, v/v) at a flow rate of 0.2 mL/min. Detection was performed on an Agilent G6410B tandem mass spectrometer by positive ion electrospray ionization in multiple reaction monitoring mode, monitoring the transitions m/z 580.5 [M + NH4]+ → 503.4 and m/z 518.2 [M + NH4]+ → 345.0 for hemslecin A and IS, respectively. The assay was linear over the concentration range of 0.5–200 ng/mL and was successfully applied to a pharmacokinetic study in rhesus monkeys. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
A rapid and sensitive LC‐MS/MS method for the quantification of fenofibric acid in rat plasma was developed and validated. Plasma samples were prepared by liquid–liquid extraction with a mixture of N‐hexane–dichloromethane–isopropanol (100:50:5, v/v/v). Isocratic chromatographic separation was performed on a reversed‐phase Discovery C18 column (2.1 × 50 mm, 5 µm). The mobile phase was methanol–water–formic (75:25:0.25, v/v/v). Detection of fenofibric acid and the internal standard (IS) diclofenac acid was achieved by ESI MS/MS in the negative ion mode using m/z 317 → m/z 213 and m/z 294 → m/z 250 transitions, respectively. The method was linear from 0.005 to 1.250 µg/mL when 100 μL plasma was analyzed. The lower limit of quantification was 0.005 µg/mL. The intra‐ and inter‐day precision values were below 8.2%, and accuracy ranged from ?0.9 to 2.1% in all quality control samples. The recovery was 90.3–94.7% and 83.3% for fenofibric acid and IS, respectively. Total run time for each sample analysis was 2.5 min. The validated method was successfully applied to a pharmacokinetic study in six rats after oral administration of fenofibrate, the ester prodrug of fenofibric acid (equivalent to fenofibric acid 5 mg/kg). The method permits laboratory scientists with access to the appropriate instrumentation to perform rapid fenofibric acid determination. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

13.
Methamphetamine abuse continues as a major problem in the USA owing to its powerful psychological addictive properties. AZ66, 3‐[4‐(4‐cyclohexylpiperazine‐1‐yl)pentyl]‐6‐fluorobenzo[d]thiazole‐2(3H)‐one, an optimized sigma receptor ligand, is a promising therapeutic agent against methamphetamine. To study the in vivo pharmacokinetics of this novel sigma receptor ligand in rats, a sensitive ultra‐performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed in rat plasma and validated. The developed method requires a small volume of plasma (100 μL) and a simple liquid–liquid extraction. The chromatographic separations were achieved in 3.3 min using an Acquity UPLC BEH Shield RP18 column. The mass spectrophotometric detection was carried out using a Waters Micromass Quattro MicroTM triple‐quadrupole system. Multiple reaction monitoring was used for the quantitation with transitions m/z 406 → m/z 181 for AZ66 and m/z 448 → m/z 285 for aripiprazole. The method was validated over a concentration range of 1–3500 ng/mL and the lower limit of quantitation was determined to be 1 ng/mL. Validation of the assay demonstrated that the developed UPLC/MS/MS method was sensitive, accurate and selective for the determination of AZ66 in rat plasma. The present method has been successfully applied to an i.v. pharmacokinetic study in Sprague–Dawley rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
An ultra performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method has been developed for the determination of nifedipine in human plasma using nifedipine‐d6 as the internal standard (IS). The plasma samples were prepared by solid‐phase extraction on Phenomenex Strata‐X cartridges employing 200 μL human plasma. Chromatography was carried out on Waters Acquity UPLC BEH C18 (50 × 2.1 mm, 1.7 µm particle size) analytical column under isocratic conditions using a mobile phase consisting of 4.0 mm ammonium acetate‐acetonitrile (15:85, v/v). The precursor → product ion transitions for nifedipine (m/z 347.2 → 315.2) and IS (m/z 353.1 → 318.1) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring and positive‐ion mode. The method was validated over a wide dynamic concentration range of 0.050–150 ng/mL. Matrix effect was assessed by post‐column analyte infusion and the mean extraction recovery was 95.6% across four quality control levels. The method is rugged and rapid with a total run time of 1.2 min and was applied to a bioequivalence study of 20 mg nifedipine tablet formulation in 30 healthy Indian subjects under fasting condition. Assay reproducibility was confirmed by reanalysis of 116 incurred samples. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
In this study, a fast UHPLC‐MS/MS method was developed and validated for the determination of a novel potent carvone Schiff base of isoniazid (CSB‐INH) in rat plasma using carbamazepine as an internal standard (IS). After a single‐step protein precipitation by acetonitrile, CSB‐INH and IS were separated on an Acquity BEHTM C18 column (50 × 2.1 mm, 1.7 µm) under an isocratic mobile phase, consisting of acetonitrile: 10 mM ammonium acetate (95:5, v/v), at a flow rate of 0.3 mL/min. Quantification was performed on a triple quadrupole tandem mass spectrometer in multiple reactions monitoring mode by using positive electrospray ionization source. The precursor to product ion transitions were set at m/z 270.08 → 79.93 for CSB‐INH and m/z 237.00 → 178.97 for IS. The proposed method was validated in compliance with US Food and Drug Administration and European Medicines Agency guidelines for bioanalytical method validation. The method was found to be linear in the range of 0.35–2500 ng/mL (r2 ≥ 0.997) with a lower limit of quantification of 0.35 ng/mL. The intra‐ and inter‐day precision values were ≤12.0% whereas accuracy values ranged from 92.3 to 108.7%. In addition, other validation results were within the acceptance criteria and the method was successfully applied in a pharmacokinetic study of CSB‐INH in rats. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
A simple LC‐MS/MS method was developed and validated for the estimation of sarpogrelate in 50 µL of rat plasma. The analyte and internal standard (IS) were extracted from rat plasma by acetonitrile precipitation and they were separated on a reversed‐phase C8 column with gradient program. The MS acquisition was performed with multiple reaction monitoring mode using m/z 430.2 to m/z 135.0 for analyte and m/z 448.2 to m/z 285.3 for IS. The calibration curves were linear over the range of 1–1000 ng/mL with the correlation coefficient greater than 0.999. With dilution integrity up to 20‐fold, the upper limit of quantification was extendable up to 15,000 ng/mL. The method was successfully applied to the analysis of rat plasma samples after single dose oral administration of sarpogrelate at 5 mg/kg to rats for the determination of its pharmacokinetics. Following oral administration the maximum mean concentration in plasma (Cmax, 11514 ng/mL) was achieved at 0.25 h (Tmax) and the area under curve (AUC0–24) was 11051 ± 3315 ng h/mL. The half‐life (t1/2) and clearance (Cl) were 2.9 ± 1.1 h and 490 ± 171 mL/h/kg, respectively. We believe that development of a method in rodent plasma would facilitate the ease of adaptability of sarpogrelate in human plasma. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
Tedizolid (TDZ) is a novel oxazolidinone class antibiotic, indicated for the treatment of acute bacterial skin and skin structure infections in adults. In this study a highly sensitive UPLC‐MS/MS assay was developed and validated for the determination of TDZ in rat plasma using rivaroxaban as an internal standard (IS). Both TDZ and IS were separated on an Acquity UPLC BEH? C18 column using an isocratic mobile phase comprising of acetonitrile–20 mm ammonium acetate (85:15, v/v), eluted at 0.3 mL/min flow rate. The plasma sample was processed by liquid liquid extraction technique using ethyl acetate as an extracting agent. The analyte and IS were detected in positive mode using electrospray ionization source. The precursor to product ion transitions at m/z 371.09 > 343.10 for TDZ and m/z 435.97 > 144.94 for IS were used for the quantification in multiple reaction monitoring mode. The calibration curve was linear in the concentration range of 0.74–1500 ng/mL and the lower limit of quantification was 0.74 ng/mL only. The developed assay was validated following standard guidelines for bioanalytical method validation (US Food and Drug Administration) and all the validation results were within the acceptable limits. The developed assay was successfully applied into a pharmacokinetic study in rats. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

18.
A sensitive and rapid LC‐MS/MS method was developed and validated for the determination of kadsurenone in rat plasma using lysionotin as the internal standard (IS). The analytes were extracted from rat plasma with acetonitrile and separated on a SB‐C18 column (50 × 2.1 mm, i.d.; 1.8 µm) at 30 °C. Elution was achieved with a mobile phase consisting of methanol–water–formic acid (65:35:0.1, v/v/v) at a flow rate of 0.30 mL/min. Detection and quantification for analytes were performed by mass spectrometry in the multiple reaction monitoring mode with positive electrospray ionization m/z at 357.1 → 178.1 for kadsurenone, and m/z 345.1 → 315.1 for IS. Calibration curves were linear over a concentration range of 4.88–1464 ng/mL with a lower limit of quantification of 4.88 ng/mL. The intra‐ and inter‐day accuracies and precisions were <8.9%. The LC‐MS/MS assay was successfully applied for oral pharmacokinetic evaluation of kadsurenone using the rat as an animal model. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
A prodrug of tapentadol, namely tapentadol carbamate (WWJ01), was synthesized to improve the bioavailability of tapentadol owing to its extensive first‐pass metabolism. In this study, a highly rapid and sensitive UPLC‐MS/MS method was developed and validated for the simultaneous determination of tapentadol and WWJ01 in rat plasma with fluconazole as an internal standard. The analytes and internal standard were treated by methanol and then separated on a Phenomenex Kinetex® XB‐C18 (2.1 × 50 mm × 2.6 μm) column at a flow rate of 0.3 mL/min. The mobile phase comprised methanol and water with a gradient elution. The mass transition ion‐pairs were m/z 222.2 → 107.0, m/z 293.2 → 71.9 and m/z 307.1 → 220.0 for tapentadol, WWJ01 and IS, respectively. Excellent linearity was observed over the concentration range of 2–1250 ng/mL (r = 0.995) with a lower limit of quantification of 2 ng/mL for both tapentadol and WWJ01. The intra‐ and inter‐day accuracy and precision for all quality control samples were within ±15%. The validated method was accurate, rapid and reproducible, and was successfully applied to a pharmacokinetic study of tapentadol and WWJ01.  相似文献   

20.
A simple, rapid and reliable liquid chromatography–electrospray ionization tandem mass spectrometry method was established and validated for the determination of methotrexate in human plasma. After a straightforward protein precipitation by acetonitrile–water (70:30, v/v), methotrexate (MTX) and p‐aminoacetophenone (used as internal standard, IS) were separated on a Column C18 column (50 × 2.1 mm, 3 µm; Column Technology, Fremont, CA, USA) using a gradient elution with mobile phase of acetonitrile and 0.03% acetic acid aqueous solution at a flow rate of 0.5 mL/min. The total chromatographic runtime was 5 min for each injection. Quantification detection was performed in a triple‐quadruple tandem mass spectrometer under positive mode monitoring the following mass transitions: m/z 455.3 → 308.3 for MTX and m/z 136.1 → 94.4 for IS. The calibration curve was linear over the range of 0.05–25.0 µmol/L with a lower limit of quantification of 0.05 µmol/L. The intra‐ and interday precisions were <5.2%, the accuracy varied from ?4.1 to 4.5%. The recovery was >94%. The LC‐MS/MS method showed an excellent agreement with the existing HPLC‐UV method using Passing–Bablok regression and Bland–Altman difference plot analysis. The validated LC‐MS/MS can be successfully applied to the routine therapeutic drug monitoring of MTX in clinical laboratories. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号