首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Due to the characteristic absorption peaks in the IR region, various molecules can be used as a matrix for infrared matrix‐assisted laser desorption/ionization (IR‐MALDI). Especially in the 6–7 µm‐band IR region, solvents used as the mobile phase for liquid chromatography have absorption peaks that correspond to their functional groups, such as O–H, CO, and CH3. Additionally, atmospheric pressure (AP) IR‐MALDI, which is applicable to liquid‐state samples, is a promising technique to directly analyze untreated samples. Herein we perform AP‐IR‐MALDI mass spectrometry of a peptide, angiotensin II, using a mid‐IR tunable laser with a tunable wavelength range of 5.50–10.00 µm and several different matrices. The wavelength dependences of the ion signal intensity of [M + H]+ of the peptide are measured using a conventional solid matrix, α‐cyano‐4‐hydroxycinnamic acid (CHCA) and a liquid matrix composed of CHCA and 3‐aminoquinoline. Other than the O–H stretching and bending vibration modes, the characteristic absorption peaks are useful for AP‐IR‐MALDI. Peptide ions are also observed from an aqueous solution of the peptide without an additional matrix, and the highest peak intensity of [M + H]+ is at 6.00 µm, which is somewhat shorter than the absorption peak wavelength of liquid water corresponding to the O–H bending vibration mode. Moreover, long‐lasting and stable ion signals are obtained from the aqueous solution. AP‐IR‐MALDI using a 6–7 µm‐band IR tunable laser and solvents as the matrix may provide a novel on‐line interface between liquid chromatography and mass spectrometry. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
The ionization mechanisms of several atmospheric pressure ion sources based on desorption and ionization of samples deposited on a surface were studied. Home‐built desorption electrospray ionization (DESI), laserspray ionization (LSI), and atmospheric pressure matrix‐assisted laser desorption/ionization (AP‐MALDI) sources were characterized using low‐molecular‐weight compounds, in particular fluorescent dyes. Detection of the desorbed and ionized species was performed by laser‐induced fluorescence and ion cyclotron resonance mass spectrometry. The dependences of the signal intensities on various experimental parameters were studied. The data obtained reveals common features, such as formation of solvated species and clusters in the ionization processes, in all of the techniques considered. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
Intact, nonvolatile, biological macromolecules can be transferred directly from the solid state into the gas phase, in ambient air, for subsequent mass spectral analysis using non‐resonant femtosecond (fs) laser desorption combined with electrospray ionization (ESI). Mass spectral measurements for neat samples, including a dipeptide, protoporphyrin IX and vitamin B12 adsorbed on a glass insulating surface, were obtained using an 800 nm, 70 fs laser with an intensity of 1013 W cm−2. No appreciable signal was detected when atmospheric matrix‐assisted or neat (matrix‐free) fs laser desorption was performed without ESI, indicating neutral desorption. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
The analysis of crude oil samples remains a tough challenge due to the complexity of the matrix and the broad range of physical and chemical properties of the various individual compounds present. In this work, atmospheric pressure laser ionization (APLI) is utilized as a complementary tool to other ionization techniques for crude oil analysis. Mass spectra obtained with electrospray ionization (ESI) and atmospheric pressure photoionization (APPI) are compared. APLI is primarily sensitive towards non‐polar aromatic hydrocarbons, which are generally present in high amounts especially in heavy crude oil samples. The ionization mechanisms of APLI vs. APPI are further investigated. The results indicate the advantages of APLI over established methods like ESI and APPI. The application of APLI in combination with Fourier transform ion cyclotron resonance mass spectrometry (FT‐ICR MS) is thus demonstrated to be a powerful tool for the analysis of aromatic species in complex crude oil fractions. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

5.
We report the evaluation of several mass spectrometry‐based methods for the determination of carisoprodol and meprobamate in samples obtained from the rat brain by in vivo intracranial microdialyis. Among the techniques that aspire to perform analyses without chromatographic separation and thereby increase throughput, chip‐based nanoelectrospray ionization and the use of an atmospheric pressure solids analysis probe fell short of requirements because of insufficient detection sensitivity and hard ionization, respectively. Although direct analysis in real time provided the required soft ionization, shortcomings of a tandem mass spectrometry‐based assay also included inadequate detection sensitivity and, in addition, poor quantitative reproducibility. Therefore, liquid chromatography coupled with atmospheric pressure chemical ionization tandem mass spectrometry was developed to determine carisoprodol and meprobamate from artificial cerebrospinal fluid as the medium. No desalting and/or extraction of the samples was necessary. The assay, combined with in vivo sampling via intracranial microdialyis, afforded time‐resolved concentration profiles for the drug and its major metabolite from the nucleus accumbens region of the brain in rats after systemic administration of carisoprodol. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
7.
Mass analysis is demonstrated for the detection of sub‐microgram quantities of explosive samples on a metallic surface at atmospheric pressure using laser electrospray mass spectrometry (LEMS). A non‐resonant femtosecond duration laser pulse vaporizes native samples for subsequent electrospray ionization and transfer into a time‐of‐flight mass spectrometer. LEMS was used to detect 2,3‐dimethyl‐2,3‐dinitrobutane (DMNB), 1,3,5‐trinitroperhydro‐1,3,5‐triazine (RDX), 3,4,8,9,12,13‐hexaoxa‐1,6‐diazabicyclo[4.4.4]tetradecane (HMTD), and 3,3,6,6,9,9‐hexamethyl‐1,2,4,5,7,8‐hexaoxacyclononane (TATP) deposited on a steel surface. LEMS was also used to directly analyze composite propellant materials containing an explosive to determine the molecular composition of the explosive pellets at atmospheric pressure. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
A method for the rapid screening and determination of amphetamine‐type designer drugs in saliva by a novel nib‐assisted paper spray‐mass spectrometry procedure is described. Under optimized conditions, the limit of detections for amphetamine derivatives (model samples: o‐, m‐, p‐chloroamphetamine and o‐, m‐, p‐fluoroamphetamine, respectively) were determined to 0.1 μg/mL by the nib‐assisted paper spray‐mass spectrometry method. This method is easier and has a higher sensitivity than similar methodologies, including atmospheric pressure/matrix‐assisted laser desorption ionization mass spectrometry and electrospray‐assisted laser desorption ionization/mass spectrometry. Data obtained using more classical separation methods, including liquid chromatography and capillary electrophoresis, are also reported.  相似文献   

9.
On‐line solid‐phase extraction (SPE) for pre‐concentration and sample cleanup is one strategy to reduce matrix effects and to simultaneously improve detection sensitivity in liquid chromatography/mass spectrometry (LC/MS). This paper describes an on‐line SPE‐LC/MS method for the determination of tributyltin (TBT) and triphenyltin (TPhT) at trace levels in water samples. The direct coupling of an on‐line C18 pre‐column to LC/MS was used to pre‐concentrate TBT and TPhT at trace levels from waters and to remove interfering matrix effects. Pre‐concentration was followed by separation of TBT and TPhT on a C18 column using a mobile phase containing 0.1% (v/v) HCOOH/5 mM HCOONH4 and methanol. While both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) can be interfaced with MS for the detection of TBT and TPhT, ESI‐MS was preferred for this application. The calibration curve for the targets was linear in the concentration range 0.1–30 µg L?1. The detection limit (signal‐to‐noise (S/N) ratio = 3) was 0.02 µg L?1 when 3.0 mL of sample was enriched on the C18 pre‐column. The recoveries of TBT and TPhT in spiked waters were from 81.0 to 101.9%. The reproducibilities for the analysis of the standard mixture (10 µg L?1) for TBT and TPhT were 13.1 and 5.0%, respectively. The developed method was an easy and fast way to analyze TBT and TPhT in water samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
Ion source pressure plays a significant role in the process of ionization and the subsequent ion transmission inside a mass spectrometer. Pressurizing the ion source to a gas pressure greater than atmospheric pressure is a relatively new approach that aims to further improve the performance of atmospheric pressure ionization sources. For example, under a super‐atmospheric pressure environment, a stable electrospray can be sustained for liquid with high surface tension such as pure water, because of the suppression of electric discharge. Even for nano‐electrospray ionization (nano‐ESI), which is known to work with aqueous solution, its stability and sensitivity can also be enhanced, particularly in the negative mode when the ion source is pressurized. A brief review on the development of super‐atmospheric pressure ion sources, including high‐pressure electrospray, field desorption and superheated ESI, and the strategies to interface these ion sources to a mass spectrometer will be given. Using a recent ESI prototype with an operating temperature at 220 °C under 27 atm, we also demonstrate that it is possible to achieve an online Asp‐specific protein digestion analysis in which the whole processes of digestion, ionization and MS acquisition could be completed on the order of a few seconds. This method is fast, and the reaction can even be monitored on a near‐real‐time basis. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
A liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry method was developed and validated to investigate the pharmacokinetic properties of β‐sitosterol, campesterol, and stigmasterol in rat plasma. Cholesterol‐d6 was used as an internal standard. To avoid interference of the three phytosterols in rat plasma and minimize matrix effects, a small volume (10 μL) of 4% bovine serum albumin was used as a surrogate matrix for making calibrators and quality control samples. Rat plasma (10 μL) samples were extracted by liquid–liquid extraction with methyl tert‐butyl ether and separated on a Kinetex C18 column. The detection was performed on a triple quadrupole tandem mass spectrometer in selected reaction monitoring mode using positive atmospheric pressure chemical ionization. This assay was linear over concentration ranges of 250–5000 ng/mL (β‐sitosterol), 250–5000 ng/mL (campesterol), and 50–2000 ng/mL (stigmasterol). Additionally, a second set of quality controls made in rat plasma was also evaluated against calibration curves made using the surrogate matrix. All the validation data, including the specificity, precision, accuracy, recovery, matrix effect, stability, and incurred sample reanalysis conformed to the acceptance requirements. Our method was successfully applied to study the pharmacokinetics of three phytosterols in rats.  相似文献   

12.
Unusual ionization behavior was observed with novel antineoplastic curcumin analogues during the positive ion mode of matrix‐assisted laser desorption ionization (MALDI) and dopant‐free atmospheric pressure photoionization (APPI). The tested compounds produced an unusual significant peak designated as [M ? H]+ ion along with the expected [M + H]+ species. In contrast, electrospray ionization, atmospheric pressure chemical ionization and the dopant‐mediated APPI (dopant‐APPI) showed only the expected [M + H]+ peak. The [M ? H]+ ion was detected with all evaluated curcumin analogues including phosphoramidates, secondary amines, amides and mixed amines/amides. Our experiments revealed that photon energy triggers the ionization of the curcumin analogues even in the absence of any ionization enhancer such as matrix, solvent or dopant. The possible mechanisms for the formation of both [M ? H]+ and [M + H]+ ions are discussed in this paper. In particular, three proposed mechanisms for the formation of [M ? H]+ were evaluated. The first mechanism involves the loss of H2 from the protonated [M + H]+ species. The other two mechanisms include hydrogen transfer from the analyte radical cation or hydride abstraction from the neutral analyte molecule. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

13.
Characterization of block size in poly(ethylene oxide)‐b‐poly(styrene) (PEO‐b‐PS) block copolymers could be achieved by matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF‐MS) after scission of the macromolecules into their constituent blocks. The performed hydrolytic cleavage was demonstrated to specifically occur on the targeted ester function in the junction group, yielding two homopolymers consisting of the constitutive initial blocks. This approach allows the use of well‐established MALDI protocols for a complete copolymer characterization while circumventing difficulties inherent to amphiphilic macromolecule ionization. Although the labile end‐group in PS homopolymer was modified by the MALDI process, PS block size could be determined from MS data since polymer chains were shown to remain intact during ionization. This methodology has been validated for a PEO‐b‐PS sample series, with two PEO of number average molecular weight (Mn) of 2000 and 5000 g mol?1 and Mn(PS) ranging from 4000 to 21,000 g mol?1. Weight average molecular weight (Mw), and thus polydispersity index, could also be reached for each segment and were consistent with values obtained by size exclusion chromatography. This approach is particularly valuable in the case of amphiphilic copolymers for which Mn values as determined by liquid state nuclear magnetic resonance might be affected by micelle formation. © 2009 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 47: 3380–3390, 2009  相似文献   

14.
Commercial copper wire and its polymer insulation cladding was investigated for the presence of three synthetic antioxidants (ADK STAB AO412S, Irganox 1010 and Irganox MD 1024) by three different mass spectrometric techniques including electrospray ionization–ion trap–mass spectrometry (ESI–IT–MS), matrix‐assisted laser desorption/ionization reflectron time‐of‐flight (TOF) mass spectrometry (MALDI–RTOF–MS) and reflectron TOF secondary ion mass spectrometry (RTOF–SIMS). The samples were analyzed either directly without any treatment (RTOF–SIMS) or after a simple liquid/liquid extraction step (ESI–IT–MS, MALDI–RTOF–MS and RTOF–SIMS). Direct analysis of the copper wire itself or of the insulation cladding by RTOF–SIMS allowed the detection of at least two of the three antioxidants but at rather low sensitivity as molecular radical cations and with fairly strong fragmentation (due to the highly energetic ion beam of the primary ion gun). ESI–IT‐ and MALDI–RTOF–MS‐generated abundant protonated and/or cationized molecules (ammoniated or sodiated) from the liquid/liquid extract. Only ESI–IT–MS allowed simultaneous detection of all three analytes in the extract of insulation claddings. The latter two so‐called ‘soft’ desorption/ionization techniques exhibited intense fragmentation only by applying low‐energy collision‐induced dissociation (CID) tandem MS on a multistage ion trap‐instrument and high‐energy CID on a tandem TOF‐instrument (TOF/RTOF), respectively. Strong differences in the fragmentation behavior of the three analytes could be observed between the different CID spectra obtained from either the IT‐instrument (collision energy in the very low eV range) or the TOF/RTOF‐instrument (collision energy 20 keV), but both delivered important structural information. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
A series of α‐acyloxyhydroperoxy aldehydes was analyzed with direct infusion electrospray ionization tandem mass spectrometry (ESI/MSn) as well as liquid chromatography coupled with the mass spectrometry (LC/MS). Standards of α‐acyloxyhydroperoxy aldehydes were prepared by liquid‐phase ozonolysis of cyclohexene in the presence of carboxylic acids. Stabilized Criegee intermediate (SCI), a by‐product of the ozone attack on the cyclohexene double bond, reacted with the selected carboxylic acids (SCI scavengers) leading to the formation of α‐acyloxyhydroperoxy aldehydes. Ionization conditions were optimized. [M + H]+ ions were not formed in ESI; consequently, α‐acyloxyhydroperoxy aldehydes were identified as their ammonia adducts for the first time. On the other hand, atmospheric‐pressure chemical ionization has led to decomposition of the compounds of interest. Analysis of the mass spectra (MS2 and MS3) of the [M + NH4]+ ions allowed recognizing the fragmentation pathways, common for all of the compounds under study. In order to get detailed insights into the fragmentation mechanism, a number of isotopically labeled analogs were also studied. To confirm that the fragmentation mechanism allows predicting the mass spectrum of different α‐acyloxyhydroperoxy aldehydes, ozonolysis of α‐pinene, a very important secondary organic aerosol precursor, was carried out. Spectra of the two ammonium cationized α‐acyloxyhydroperoxy aldehydes prepared with α‐pinene, cis‐pinonic acid as well as pinic acid were predicted very accurately. Possible applications of the method developed for the analysis of α‐acyloxyhydroperoxy aldehydes in SOA samples, as well as other compounds containing hydroperoxide moiety are discussed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
To free analytical resources for new classes of doping substances, such as banned proteins, maximization of the number of compounds that can be determined with high sensitivity in a single run is highly urgent. This study demonstrates an application of ‘wrong‐way‐round ionization’ for the simultaneous detection of multiple classes of doping substances without the need to switch the polarity. A screening method for the detection of 137 compounds from various classes of prohibited substances (stimulants, diuretics, β2‐agonists, β‐blockers, antiestrogens, glucocorticosteroids and anabolic agents) has been developed. The method involves an enzymatic hydrolysis, liquid–liquid extraction and detection by liquid chromatography/orbitrap mass spectrometry with wrong‐way‐round ionization. Up to 64% of compounds had a 10‐fold lower limit of detection (LOD) than the minimum required performance limit. To compare the efficiency of conventional ionization relative to wrong‐way‐round ionization of doping substances in + ESI, a fortified blank urine sample at the minimum required performance limit was analyzed using two ESI approaches. All compounds were detected with markedly better S/N in a high‐pH mobile phase, with the exception of acetazolamide (minimal change in S/N, < 20%).The method was validated by spiking 10 different blank urine samples at five different concentrations. Validation parameters included the LOD, selectivity, ion suppression, extraction recovery and repeatability. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

17.
Sonic-spray ionization (SSI) is a previously developed soft ionization technique which does not need auxiliary methods such as voltage, heating, laser, or corona discharge. Spray ionization can be achieved under normal temperature and atmospheric pressure by inputting high-speed gas coaxial within the capillary. As an atmospheric pressure ion source, this technique was widely used as the interface of liquid chromatography-mass spectrometry at the beginning of its development. Based on the principles of sonic-spray ionization, a variety of easy ambient sonic-spray ionization derived techniques have been developed, which can be used for the in-situ, rapid and real-time analysis of samples with little or without any sample pretreatment. In this paper, the principless and characteristics of sonic-spray ionization were elaborated, and the progress of its application in life sciences, food safety, forensic chemistry, reaction monitoring, and other related fields were summarized.  相似文献   

18.
A simple and effective digestion method was developed using a syringe. A 3 mL syringe was used to apply a pressure of 6 atm to expedite tryptic digestion. Application of a pressure of 6 atm during digestion resulted in better digestion efficiency than digestion under atmospheric pressure. The protein peaks in the matrix‐assisted laser desorption/ionization mass spectra of three model proteins (cytochrome c, horse heart myoglobin, and bovine serum albumin (BSA)) completely disappeared within 30 min at 37°C under a pressure of 6 atm, with greater numbers of peptides observed in 30 min pressure‐assisted digestion than in overnight atmospheric pressure digestion. This is mostly due to the miscleaved peptides. Similar sequence coverages were obtained for 30 min pressure‐assisted digestion and overnight atmospheric pressure digestion of the three model proteins (92% vs. 88% for cytochrome c, 100% vs. 97% for horse heart myoglobin, and 53% vs. 53% for BSA). Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
Phenethyl isothiocyanate (PEITC) is a promising chemopreventive agent present in cruciferous vegetables. This paper describes the development of a method for the determination of PEITC in human plasma by liquid chromatography/tandem mass spectrometry (LC‐MS/MS). Atmospheric‐pressure chemical ionization was found more suitable for ionization of PEITC than electrospray ionization. Because of the lability of PEITC, a combination of low temperature and acidification was applied to minimize the degradation during the sample collection and preparation procedure. A simple protein precipitation with acetonitrile was used for the preparation of plasma samples. The analyte and 1‐phenylpropyl isothiocyanate as internal standard (IS) were subjected to chromatographic analysis on a C18 column (50 × 2.1 mm, 5 µm) using 85% methanol as mobile phase at a flow rate of 0.3 mL/min. The total analysis time for each chromatograph was 3 min and the results were linear over the studied range (5.00–250 ng/mL). The intra‐ and inter‐day precision values were acceptable as per US Food and Drug Administration guidelines. This method was successfully applied in the determination of PEITC concentrations in plasma samples from healthy chinese Volunteers. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

20.
The structural information and spatial distribution of molecules in biological tissues are closely related to the potential molecular mechanisms of disease origin, transfer, and classification. Ambient ionization mass spectrometry imaging is an effective tool that provides molecular images while describing in situ information of biomolecules in complex samples, in which ionization occurs at atmospheric pressure with the samples being analyzed in the native state. Ambient ionization mass spectrometry imaging can directly analyze tissue samples at a fairly high resolution to obtain molecules in situ information on the tissue surface to identify pathological features associated with a disease, resulting in the wide applications in pharmacy, food science, botanical research, and especially clinical research. Herein, novel ambient ionization techniques, such as techniques based on spray and solid‐liquid extraction, techniques based on plasma desorption, techniques based on laser desorption ablation, and techniques based on acoustic desorption were introduced, and the data processing of ambient ionization mass spectrometry imaging was briefly reviewed. Besides, we also highlight recent applications of this imaging technology in clinical researches and discuss the challenges in this imaging technology and the perspectives on the future of the clinical research.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号