首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Since 1999, substantial research has been devoted to the development of liquid-phase microextraction (LPME) based on porous hollow fibers. With this technology, target analytes are extracted from aqueous samples, through a thin supported liquid membrane (SLM) sustained in the pores in the wall of a porous hollow fiber, and further into a microL volume of acceptor solution placed inside the lumen of the hollow fiber. After extraction, the acceptor solution is directly subjected to a final chemical analysis by liquid chromatography (HPLC), gas chromatography (GC), capillary electrophoresis (CE), or mass spectrometry (MS). In this review, LPME will be discussed with focus on extraction principles, historical development, fundamental theory, and performance. Also, major applications have been compiled, and recent forefront developments will be discussed.  相似文献   

2.
The applicability of in-vial two-phase liquid-phase microextraction (LPME) in porous hollow polypropylene fiber was studied for the sample preparation of unconjugated anabolic steroids in urine. Four different anabolic steroids - metabolites of fluoxymesterone, 4-chlorodehydromethyltestosterone, stanozolol and danazol - were used as test compounds and methyltestosterone as an internal standard. A standard two-phase LPME method for use with liquid chromatography/mass spectrometry (LC/MS) was set up and the influence of different parameters, including the nature of organic solvent, extraction time, salting-out and temperature, on the LPME process was investigated. Taking advantage of the preliminary studies, a novel two-phase LPME method utilizing simultaneous in-fiber silylation was developed and validated for gas chromatographic/mass spectrometric (GC/MS) analysis of a danazol metabolite in urine. In all, LPME allowed a very straightforward, simple and selective way to prepare urine samples for steroid analysis, being most suitable for hydrophobic steroids. The LPME method with in-fiber derivatization for GC/MS analysis exhibited high sensitivity, repeatability and linearity and enabled simultaneous filtration, extraction, enrichment and derivatization of the analyte from urine matrix without any other steps in sample pretreatment.  相似文献   

3.
Two different modes of three‐phase hollow fiber liquid‐phase microextraction were studied for the extraction of two herbicides, bensulfuron‐methyl and linuron. In these two modes, the acceptor phases in the lumen of the hollow fiber were aqueous and organic solvents. The extraction and determination were performed using an automated hollow fiber microextraction instrument followed by high‐performance liquid chromatography. For both three‐phase hollow fiber liquid‐phase microextraction modes, the effect of the main parameters on the extraction efficiency were investigated and optimized by central composite design. Under optimal conditions, both modes showed good linearity and repeatability, but the three‐phase hollow fiber liquid‐phase microextraction based on two immiscible organic solvents has a better extraction efficiency and figures of merit. The calibration curves for three‐phase hollow fiber liquid‐phase microextraction with an organic acceptor phase were linear in the range of 0.3–200 and 0.1–150 μg/L and the limits of detection were 0.1 and 0.06 μg/L for bensulfuron‐methyl and linuron, respectively. For the conventional three‐phase hollow fiber liquid‐phase microextraction, the calibration curves were linear in the range of 3.0–250 and 15–400 μg/L and LODs were 1.0 and 5.0 μg/L for bensulfuron‐methyl and linuron, respectively. The real sample analysis was carried out by three‐phase hollow fiber liquid phase microextraction based on two immiscible organic solvents because of its more favorable characteristics.  相似文献   

4.
A new derivatization–extraction method for preconcentration of seleno amino acids using hollow fiber liquid phase microextraction (HF‐LPME) was developed for the separation and determination of seleno amino acids in biological samples by gas chromatography–inductively coupled plasma mass spectrometry (GC–ICP‐MS). Derivatization was performed with ethyl chloroformate (ECF) to improve the volatility of seleno amino acids. Parameters influencing microextraction, including extraction solvent, pH of sample solution, extraction time, stirring speed, and inorganic salt concentration have been investigated. Under the optimal conditions, the limits of detection (LODs) obtained for Se‐methyl‐selenocysteine (SeMeCys), selenomethionine (SeMet), and selenoethionine (SeEth) were 23, 15, and 11 ng Se l−1, respectively. The relative standard deviations (RSDs) were 14.6%, 16.4%, and 19.4% for SeMeCys, SeMet, and SeEth (c = 1.0 ng ml−1, n = 7), respectively, and the RSDs for SeMeCys, SeMet could be improved obviously if SeEth was utilized as the internal standard. The proposed method was applied for the determination of seleno amino acids in extracts of garlic, cabbage, and mushroom samples, and the recoveries for the spiked samples were in the range of 96.8–108% and 93.4–115% with and without the use of SeEth as internal standard. The developed method was also applied to the analysis of SeMet in a certified reference material of SELM‐1 yeast and the determined value is in good agreement with the certified value. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

5.
A liquid-phase microextraction (LPME) method using a micropipette with disposable tips was demonstrated for coupling to atmospheric pressure MALDI-MS (AP-MALDI/MS) as a concentrating probe for rapid analysis and quantitative determination of nortriptyline drug from biological matrices including human urine and human plasma. This technique was named as micropipette extraction (MPE). The best optimized parameters of MPE coupled to AP-MALDI/MS experiments were extraction solvent, toluene; extraction time, 5 min; sample agitation rate, 480 rpm; sample pH, 7; salt concentration, 30%; hole size of micropipette tips, 0.61 mm (id); and matrix concentration, 1000 ppm using alpha-cyano-4-hydroxycinnamic acid (CHCA) as a matrix. Three detection modes of AP-MALDI/MS analysis including full scan, selective ion monitor (SIM), and selective reaction monitor (SRM) of MS/MS were also compared for the MPE performance. The results clearly demonstrated that the MS/MS method provides a wider linear range and lower LODs but poor RSDs than the full scan and SIM methods. The LOD values for the MPE under SIM and MS/MS modes in water, urine, and plasma were 6.26, 47.5, and 94.9 nM, respectively. The enrichment factors (EFs) of this current approach were 36.5-43.0 fold in water. In addition, compared to single drop microextraction (SDME) and LPME using a dual gauge microsyringe with a hollow fiber (LPME-HF) technique, the LODs acquired by the MPE method under MS/MS modes were comparable to those of LPME-HF and SDME but it is more convenient than both methods. The advantages of this novel method are simple, easy to use, low cost, and no contamination between experiments since disposable tips were used for the micropipettes. The MPE has the potential to be widely used in the future because it only requires a simple micropipette to perform all extraction processes. We believe that this technique can be a powerful tool for MALDI/MS analysis of biological samples and clinical applications.  相似文献   

6.
A simple and efficient hollow fiber liquid‐phase microextraction (HF‐LPME) technique in conjunction with high‐performance liquid chromatography is presented for extraction and quantitative determination of aristolochic acid I in human urine samples. Several parameters influencing the efficiency of HF‐LPME were investigated and optimized, including extraction solvent, stirring rate, extraction time, pH of donor phase and acceptor phase. Excellent sample clean‐up was observed and good linearity with coefficient of 0.9999 was obtained in the range of 15.4–960 µg/L. This method provided a 230‐fold enrichment factor and good repeatability with relative standard deviations (RSD) lower than 6.0%. The limit of detection value for the analyte in urine sample was 0.01 µg/L at a signal‐to‐noise ratio of 3. The extraction recovery from urine samples was 61.8% with an RSD of 9.71%. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
A simple, inexpensive and disposable device for liquid-phase microextraction (LPME) is presented for use in combination with capillary gas chromatography (GC), capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC). 1-4 ml samples of human urine or plasma were filled into conventional 4-ml vials, whereafter 15-25 microl of the extraction medium (acceptor solution) was filled into a short piece of a porous hollow fiber and placed into the sample vial. The drugs of interest were extracted from the sample solutions and into the small volumes of acceptor solution based on high partition coefficients and were preconcentrated by a factor of 30-125. For LPME in combination with GC, the porous hollow fiber was filled with 15 microl n-octanol as the acceptor solution. Following 30 min of extraction, the organic acceptor solution was injected directly into the GC system. For LPME in combination with CE and HPLC, n-octanol was immobilized within the pores of the hollow fiber, while the internal volume of the fiber was filled with either 25 microl of 0.1 M HCl (for extraction of basic compounds) or 25 microl 0.02 M NaOH (for acidic compounds). Following 45 min extraction, the aqueous acceptor solution was injected directly into the CE or HPLC system. Owing to the low cost, the extraction devices were disposed after a single extraction which eliminated the possibility of carry over effects. In addition, because no expensive instrumentation was required for LPME, 10-30 samples were extracted in parallel to provide a high number of samples per unit time capacity.  相似文献   

8.
A novel technique utilizing the adsorptive potential of immobilized multi‐walled carbon nanotubes (I‐MWCNT) in hollow fiber liquid‐phase microextraction (HF‐LPME) was developed for the determination of diuretics in urine. In this study, the potential of carbon nanotubes as a sorbent for three‐phase liquid‐phase microextraction of diuretics from urine samples was evaluated. Analysis was performed using liquid chromatography‐tandem mass spectrometry (LC‐MS/MS). A novel method was applied to detect acetazolamide (AAA), chlorothiazide (CTA), hydrochlorothiazide (HCT), hydroflumethiazide (HFT), clopamide (CA), trichlormethiazide (TCM), althiazide (AT) and bendroflumethiazide (BFT) in urine. Two‐step extractions using different times and temperatures for each step were adopted. Parameters influencing the extraction efficiency, including the extraction solvent, sample pH, salt concentration, extraction time and extraction temperature were systematically optimized. Under the resulting optimal extraction conditions, this method showed good linearity over an analytes concentration range of 1 to 1000 ng/mL, high extraction repeatability with relative standard deviations of less than 6%, and low detection limits (0.09 to 0.51 ng/mL). The application of the methods to the determination of diuretics in real samples was tested by analyzing urine samples of patient.  相似文献   

9.
This paper reports the applicability of two‐phase and three‐phase hollow fiber based liquid‐phase microextraction (HF‐LPME) for the extraction of hydrochlorothiazide (HYD) and triamterene (TRM) from human urine. The HYD in two‐phase HF‐LPME is extracted from 24 mL of the aqueous sample into an organic phase with microliter volume located inside the pores and lumen of a polypropylene hollow fiber as acceptor phase, but the TRM in three‐phase HF‐LPME is extracted from aqueous donor phase to organic phase and then back‐extracted to the aqueous acceptor phase, which can be directly injected into HPLC for analysis. Under optimized conditions preconcentration factors of HYD and TRM were obtained as 128 and 239, respectively. The calibration curves were linear (R2 ≥ 0.995) in the concentration range of 1.0–100 µg/L for HYD and 2.0–100 µg/L for TRM. The limits of detection for HYD and TRM were 0.5 µg/L. The intra‐day and inter‐day RSD based on four replicates were obtained as ≤5.8 and ≤9.3%, respectively. The methods were successfully applied for determining the concentration of the drugs in urine samples. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
Anabolic androgenic steroids (AAS) are metabolized extensively in the human body, resulting mainly in the formation of glucuronide conjugates. Current detection methods for AAS are based on gas chromatographic/mass spectrometric (GC/MS) analysis of the hydrolyzed steroid aglycones. These analyses require laborious sample preparation steps and are therefore time consuming. Our interest was to develop a rapid and straightforward method for intact steroid glucuronides in biological samples, using liquid-phase microextraction (LPME) sample clean-up and concentration method combined with liquid chromatographic/tandem mass spectrometric (LC/MS/MS) analysis. The applicability of LPME was optimized for 13 steroid glucuronides, and compared with conventional liquid-liquid extraction (LLE) and solid-phase extraction (SPE) procedures. An LC/MS/MS method was developed for the quantitative detection of AAS glucuronides, using a deuterium-labeled steroid glucuronide as the internal standard. LPME, owing to its high specificity, was shown to be better suited than conventional LLE and SPE for the clean-up of urinary AAS glucuronides. The LPME/LC/MS/MS method was fast and reliable, offering acceptable reproducibility and linearity with detection limits in the range 2-20 ng ml(-1) for most of the selected AAS glucuronides. The method was successfully applied to in vitro metabolic studies, and also tested with an authentic forensic urine sample. For a urine matrix the method still has some unsolved problems with specificity, which should be overcome before the method can be reliably used for doping analysis, but still offering additional and complementary data for current GC/MS analyses.  相似文献   

11.
In this study, two‐phase hollow‐fiber liquid‐phase microextraction and three‐phase hollow‐fiber liquid‐phase microextraction based on two immiscible organic solvents were compared for extraction of oxazepam and Lorazepam. Separations were performed on a liquid chromatography with mass spectrometry instrument. Under optimal conditions, three‐phase hollow‐fiber liquid‐phase microextraction based on two immiscible organic solvents has a better extraction efficiency. In a urine sample, for three‐phase hollow fiber liquid‐phase microextraction based on two immiscible organic solvents, the calibration curves were found to be linear in the range of 0.6–200 and 0.9–200 μg L?1 and the limits of detection were 0.2 and 0.3 μg L?1 for oxazepam and lorazepam, respectively. For two‐phase hollow fiber liquid‐phase microextraction, the calibration curves were found to be linear in the range of 1–200 and 1.5–200 μg L?1 and the limits of detection were 0.3 and 0.5 μg L?1 for oxazepam and lorazepam, respectively. In a urine sample, for three‐phase hollow‐fiber‐based liquid‐phase microextraction based on two immiscible organic solvents, relative standard deviations in the range of 4.2–4.5% and preconcentration factors in the range of 70–180 were obtained for oxazepam and lorazepam, respectively. Also for the two‐phase hollow‐fiber liquid‐phase microextraction, preconcentration factors in the range of 101–257 were obtained for oxazepam and lorazepam, respectively.  相似文献   

12.
Derivatization at the injection port following hollow‐fiber‐based liquid–liquid–liquid microextraction with tetramethylammonium acetate as a dual‐function reagent, i.e. an acceptor and derivatization reagent, for the determination of benzoic acid (BA) and sorbic acid (SA) in real samples by GC was developed. BA and SA were extracted from aqueous samples to an organic phase impregnated into the pores of the hollow fiber wall, and then back‐extracted to the acceptor solution located inside the lumen of the hollow fiber. Upon injection, the extracted analytes were quantitatively derivatized to their methyl esters with tetramethylammonium acetate in the GC injection port. Several parameters related to the derivatization and extraction efficiency were optimized. The linearity was satisfactory over a concentration range of 0.1–50 mg/L with r > 0.993 for both analytes. The LODs were 2.0 μg/L for SA and 20 μg/L for BA. The recoveries (83–116%) and precisions (RSDs of 1.2–11.4% (n = 3)) were examined by analyzing real spiked samples. The enrichment factors of BA and SA were 300 and 425. The results demonstrated that this is a simple, rapid, accurate, and sensitive method for the determination of BA and SA in various samples.  相似文献   

13.
In hollow fiber membrane liquid-phase microextraction (LPME), target analytes are extracted from aqueous samples and into a supported liquid membrane (SLM) sustained in the pores in the wall of a small porous hollow fiber, and further into an acceptor phase present inside the lumen of the hollow fiber. The acceptor phase can be organic, providing a two-phase extraction system compatible with capillary gas chromatography, or the acceptor phase can be aqueous resulting in a three-phase system compatible with high-performance liquid chromatography or capillary electrophoresis. Due to high enrichment, efficient sample clean-up, and the low consumption of organic solvent, substantial interest has been devoted to LPME in recent years. This paper reviews important applications of LPME with special focus on bioanalytical and environmental chemistry, and also covers a new possible direction for LPME namely electromembrane extraction, where analytes are extracted through the SLM and into the acceptor phase by the application of electrical potentials.  相似文献   

14.
In this paper, a three‐phase hollow fiber liquid‐phase microextraction (HF‐LPME) method combined with high‐performance liquid chromatography (HPLC) was developed for the determination of hypoxanthine (HX), xanthine (Xan) and adenine (A) and then for the first time successfully applied to the analysis of HX, Xan and A in Alysicarpus vaginalis (L.) DC. medicinal materials. Different factors affecting the HF‐LPME procedure were investigated and optimized. Under optimal extraction conditions (1‐octanol as organic solvent, pH of the donor and acceptor phase 10.0 and 3.5, respectively, extraction time 40 min, stirring rate 800 rpm and salt addition 10%, w/v), HX, Xan and A could be determined within the test ranges with a good correlation coefficient (r2 > 0.9992). The limit of detection for HX, Xan and A was 153, 173 and 97 ng/mL, respectively, and the intra‐ and inter‐day relative standard deviations were no more than 9.8%. The content of HX, Xan and A in Alysicarpus vaginalis (L.) DC. medicinal materials was 120.40, 18.37 and 62.75 µg/g, respectively. This procedure afforded a convenient, sensitive, accurate and inexpensive method with a high extraction efficiency for determination of HX, Xan and A. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
A method has been established for the determination of four pharmaceutically active compounds (ibuprofen, ketoprofen, naproxen and clofibric acid) in water samples using dynamic hollow fiber liquid-phase microextraction (HF/LPME) followed by gas chromatography (GC) injection port derivatization and GC–mass spectrometric (MS) determination. Dynamic HF/LPME is a novel approach to microextraction that involves the use of a programmable syringe pump to move the liquid phases participating in the extraction so as to facilitate the process. Trimethylanilinium hydroxide (TMAH) was used as derivatization reagent for the analytes to increase their volatility and improve chromatographic separation. Parameters that affect extraction efficiency (selection of organic solvent, volume of organic solvent, agitation in the donor phase, plunger movement and extraction time) were investigated. Under optimal conditions, the proposed method provided good enrichment factors up to 251, reproducibility ranging from 3.26% to 10.61%, and good linearity from 0.2 to 50 μg/L. The limits of detection ranged between 0.01 and 0.05 μg/L (S/N = 3) using selective ion monitoring. This method was applied to the determination of the four pharmaceutically active compounds in tap water and wastewater collected from a drain in the vicinity of a hospital.  相似文献   

16.
In this study, the viability of two membrane‐based microextraction techniques for the determination of endocrine disruptors by high‐performance liquid chromatography with diode array detection was evaluated: hollow fiber microporous membrane liquid–liquid extraction and hollow‐fiber‐supported dispersive liquid–liquid microextraction. The extraction efficiencies obtained for methylparaben, ethylparaben, bisphenol A, benzophenone, and 2‐ethylhexyl‐4‐methoxycinnamate from aqueous matrices obtained using both approaches were compared and showed that hollow fiber microporous membrane liquid–liquid extraction exhibited higher extraction efficiency for most of the compounds studied. Therefore, a detailed optimization of the extraction procedure was carried out with this technique. The optimization of the extraction conditions and liquid desorption were performed by univariate analysis. The optimal conditions for the method were supported liquid membrane with 1‐octanol for 10 s, sample pH 7, addition of 15% w/v of NaCl, extraction time of 30 min, and liquid desorption in 150 μL of acetonitrile/methanol (50:50 v/v) for 5 min. The linear correlation coefficients were higher than 0.9936. The limits of detection were 0.5–4.6 μg/L and the limits of quantification were 2–16 μg/L. The analyte relative recoveries were 67–116%, and the relative standard deviations were less than 15.5%.  相似文献   

17.
Two microextraction techniques – liquid phase microextraction based on solidification of a floating organic drop (LPME‐SFO) and dispersive liquid–liquid microextraction combined with a solidification of a floating organic drop (DLLME‐SFO) – are explored for benzene, toluene, ethylbenzene and o‐xylene sampling and preconcentration. The investigation covers the effects of extraction solvent type, extraction and disperser solvents' volume, and the extraction time. For both techniques 1‐undecanol containing n‐heptane as internal standard was used as an extracting solvent. For DLLME‐SFO acetone was used as a disperser solvent. The calibration curves for both techniques and for all the analytes were linear up to 10 μg/mL, correlation coefficients were in the range 0.997–0.998, enrichment factors were from 87 for benzene to 290 for o‐xylene, detection limits were from 0.31 and 0.35 μg/L for benzene to 0.15 and 0.10 μg/L for o‐xylene for LPME‐SFO and DLLME‐SFO, respectively. Repeatabilities of the results were acceptable with RSDs up to 12%. Being comparable with LPME‐SFO in the analytical characteristics, DLLME‐SFO is superior to LPME‐SFO in the extraction time. A possibility to apply the proposed techniques for volatile aromatic hydrocarbons determination in tap water and snow was demonstrated.  相似文献   

18.
多孔中空纤维液相微萃取技术的研究进展   总被引:4,自引:0,他引:4  
基于多孔中空纤维的液相微萃取集采样、萃取和浓缩于一体,具有成本低,易与多种分析仪器联用等特点,该技术不仅可得到较高的富集倍数和回收率,而且具有突出的样品净化功能,有机溶剂用量非常少,是一种环境友好的样品前处理新技术,国内尚未广泛应用。本文综述了多孔中空纤维液相微萃取的主要装置、萃取模式、影响因素及其应用,引用文献54篇。  相似文献   

19.
In this study, a novel solidification of floating organic drop liquid‐phase microextraction cell fishing with gas chromatography–mass spectrometry (SFOD‐LPME‐CF‐GC‐MS) method was established and used to screen, isolate and analyze bioactive components from Amomum villosum Lour. extract. Through comparision of its effect on the models of normal cell and inflammatory cells, anti‐inflammatory active components of essential oil from A. villosum Lour. were readily screened, and the components obtained are in agreement with related pharmacological articles. SFOD‐LPME‐CF‐GC‐MS was used to analyze the interaction of A. villosum Lour. extracts with normal and lipopolysaccharide‐stimulated RAW264.7 macrophage cells. The effect of A. villosum Lour. essential oil extracts in the LPS‐stimulated RAW264.7 model were also assessed in terms of cytotoxicity and nitric oxide production as an indication of bioactivity. Three potentially bioactive components were identified, demonstrating that SFOD‐LPME‐CF‐GC‐MS can be used successfully in the drug‐screening process. This approach avoids the requirement for protein precipitation, but more importantly, generates a high concentration ratio, allowing analysis of trace components in traditional Chinese medicines. SFOD‐LPME‐CF‐GC‐MS is a simple, fast, effective and reliable method for the screening and analysis of bioactive components, and it can be extended to screen other bioactive components from TCMs. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

20.
A simple and sensitive methodology based on liquid‐phase microextraction (LPME) followed by GC‐MS, was developed for the determination of trihalomethanes (THMs) in drinking water. A microdrop of organic solvent was floated on the surface of the aqueous sample and it was agitated for a desired time. Then, the sample vial was cooled by inserting it into an ice bath for 4 min. The solidified solvent was transferred into a suitable vial and immediately melted. The extract was directly injected into the GC. Microextraction efficiency factors were investigated and optimized: 7 μL 1‐undecanol microdrop exposed for 15 min floated on the surface of a 10.0 mL aqueous sample with the temperature of 60°C containing 3 M of NaCl and stirred at 750 rpm. Under the selected conditions, enrichment factors (EFs) up to 482‐fold, LOD of 0.03–0.08 μg/L (S/N = 3) and dynamic linear ranges of 0.10–100 μg/L were obtained. A reasonable repeatability (RSD < 8.6%, n = 8) with satisfactory linearity (r2 ? 0.9947) of results illustrated a good performance of the present method. The protocol proved to be rapid, cost‐effective, and is a green procedure for the screening purposes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号