首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this study, a gas chromatography/mass spectrometry (GC/MS) method was developed and validated for the metabolic profiling of human colon tissue. Each colon tissue sample (20 mg) was ultra‐sonicated with 1 mL of a mixture of chloroform/methanol/water in the ratio of 20:50:20 (v/v/v), followed by centrifugation, collection of supernatant, drying, removal of moisture using anhydrous toluene and finally derivatization using N‐methyl‐N‐trifluoroacetamide (MSTFA) with 1% trimethylchlorosilane (TMCS). A volume of 1 µL of the derivatized mixture was injected into the GC/MS system. A total of 53 endogenous metabolites were separated and identified in the GC/MS chromatogram, all of which were selected to evaluate the sample stability and precision of the method. Of the identified endogenous metabolites 19 belonging to diverse chemical classes and covering a wide range of the GC retention times (Rt) were selected to investigate the quantitative linearity of the method. The developed GC/MS method demonstrated good reproducibility with intra‐ and inter‐day precision within relative standard deviation (RSD) of ±15%. The metabolic profiles of the intact tissue were determined to be stable (100 ± 15%) for up to 90 days at ?80°C. Satisfactory results were also obtained in the case of other stability‐indicating studies such as freeze/thaw cycle stability, bench‐top stability and autosampler stability. The developed method showed a good linear response for each of the 19 analytes tested (r2 > 0.99). Our GC/MS metabolic profiling method was successfully applied to discriminate biopsied colorectal cancer (CRC) tissue from their matched normal tissue obtained from six CRC patients using orthogonal partial least‐squares discriminant analysis [two latent variables, R2Y = 0.977 and Q2 (cumulative) = 0.877]. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
This paper presents a simple and reliable gas chromatography/mass spectrometry (GC/MS) method for the metabonomic analysis of human urine samples. The sample preparation involved the depletion of excess urea via treatment with urease and subsequent protein precipitation using ice-cold ethanol. An aliquot of the mixture was separated, dried, trimethylsilyl (TMS)-derivatized and 1.0 microL of the derivatized extract was injected into the GC/MS system via split injection (1:10). Approximately 150 putative metabolites belonging to different chemical classes were identified from the pooled human urine samples. All the identified metabolites were selected to evaluate precision and stability of the GC/MS assay. More than 95% of the metabolites demonstrated good reproducibility, with intra-day and inter-day precision values below 15%. Metabolic profiling of 53 healthy male and female urine samples in combination with pattern recognition techniques was performed to further validate the GC/MS metabolite profiling assay. Principal component analysis (PCA) followed by orthogonal partial least squares analysis (OPLS) revealed differences between urinary metabolite profiles of healthy male and female subjects. This validated GC/MS metabolic profiling method may be further applied to the metabonomic screening of urinary biomarkers in clinical studies. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

3.
Chloramine-T is a disinfectant being developed as a treatment for bacterial gill disease in cultured fish. As part of the drug approval process, a method is required for the confirmation of chloramine-T residues in edible fish tissue. The marker residue that will be used to determine the depletion of chloramine-T residues from the edible tissue of treated fish is para-toluenesulfonamide (p-TSA), a metabolite of chloramine-T. The development and validation of a procedure for the confirmation of p-TSA is described. Homogenized fish tissue is dried by mixing with anhydrous sodium sulfate, and the mixture is extracted with methylene chloride. The extract is passed through a silica gel solid-phase extraction column, from which p-TSA is subsequently eluted with acetonitrile. The acetonitrile extract is evaporated, and the oily residue is dissolved in hexane. The hexane solution is shaken with fresh acetonitrile. The acetonitrile solution is evaporated and the residue is redissolved in dilute potassium hydroxide solution. The aqueous solution is extracted with methylene chloride to further remove more of the fat co-extractive. The aqueous solution is reacted with pentafluorobenzyl bromide in presence of tetrabutylammonium hydrogensulfate. The resulting di-(pentafluorobenzyl) derivative of p-TSA is analyzed by gas chromatography/mass spectrometry. This method permits the confirmation of p-TSA in edible fish tissue at 20 ppb.  相似文献   

4.
A GC/tandem quadrupole MS/MS method was developed and validated for the determination of the residues of 140 pesticides in fruits and vegetables. Pesticides were extracted from samples by using a miniaturized acetonitrile-based extraction technique known as the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method. Validation studies were carried out on carrots, tomatoes, and strawberries. In order to reduce systematic errors due to a matrix-induced effect, quantification was carried out using matrix-matched standard calibration curves. The recovery and precision results satisfied the European Union criteria (i.e., average recoveries were in the range 70-120% with RSDs < or = 20%) for 125 of the 140 pesticides at a spiking level of 0.01 mg/kg. At the higher spiking levels, there were just two instances of overall average recovery < 70% (chlorothalonil and captan). The measurement uncertainty was estimated following a "top down" approach as being 21 and 35%, on average, based on validation and ongoing recovery data, respectively (coverage factor k = 2, confidence level 95%). Practical application to 541 samples of apples, tomatoes, strawberries, cucumbers, currants, mushrooms, carrots, peppers, pears, onions, and gooseberries under strict QC conditions demonstrated the ruggedness of the total procedure.  相似文献   

5.
Many pollutants currently released into the environment may cause adverse effects on exposed organisms leading to disruption of the endocrine system. Among them are natural compounds such as phytoestrogens and phytosterols, found in various plants and mycotoxins produced by a wide range of fungal species. The presence of some classes of phytoestrogens and phytosterols has been demonstrated in environmental samples while little information can be found about the presence of mycotoxins. Due to the complexity of environmental matrices and the low concentrations normally found, sensitive and selective methods are required for an unequivocal quantification of this type of compounds. The aim of this study was to develop and validate an analytical method for the simultaneous quantification of seven phytoestrogens, two phytosterols and three mycotoxins in estuarine water samples. The method consisted of the preconcentration of estuarine water samples (1 L) on 200 mg OASIS HLB cartridges, followed by a clean-up step in 1 g silica cartridges and quantification by gas chromatography with mass spectrometry ion trap analyser. Validation parameters were evaluated and the method demonstrated to be selective and linear with correlations higher than 0.99. Method detection limits were in the ng L?1 levels ranging from 18.0 to 90.0 ng L?1, recovery rates ranged from 59.8% to 99.5% and precision (RSD) from 5.5% and 9.7%. The feasibility of the method was demonstrated in surface water samples from Douro River estuary, a polluted estuary, with reported incidence of endocrine-disrupting phenomena.  相似文献   

6.
A new gas chromatography/mass spectrometry (GC/MS) system was designed and evaluated which we have named 'Supersonic GC/MS'. It is based on a modification of a commercially available GC/MS system to include a supersonic molecular beam (SMB) MS interface. In this system the standard electron ionization (EI) ion source was replaced with a fly-through EI ion source mounted in the path of the SMB. A hyperthermal surface ionization (HSI) ion source combined with a 90 degrees ion mirror (for the EI-produced ions) was also added, and placed inside the quadrupole mass analyzer in place of its original EI ion source. The 'Supersonic GC/MS' system requires 18 cm added bench space plus the addition of an air-cooled 60 L/s diffusion pump and a 537 L/min rotary pump. The system is user friendly since all the gas flow rates, heated zones, sampling and data analysis are performed the same way as the original system and are computer-controlled via the original software. Similar EI sensitivity was obtained as with the original system for hexachlorobenzene and octafluoronaphthalene, while improved EI detection limits were demonstrated for methyl stearate and eicosane due to the significant enhancement of their molecular ion abundances. A GC/MS detection limit of 500 ag for pyrene was demonstrated using HSI. Good supersonic expansion cooling was achieved with large alkanes, despite the use of a rotary pump at the nozzle chamber instead of a diffusion pump. High temperature GC/MS analysis was demonstrated for large polycyclic aromatic hydrocarbons (PAHs) including ovalene and decacyclene (ten rings). Library searches with EI mass spectra are demonstrated, and it is explained why the enhancement of the molecular ion actually improves the library search in most cases. The analysis of large phthalate esters is also described, and the improvement obtained is shown to originate from their enhanced molecular and high mass fragment ions.  相似文献   

7.
Spectroscopy Laboratory, The Dow Chemical Company, Midland, Michigan, USA In December 1955 or thereabouts, the authors coupled a homemade gas chromatograph to a research time-of-flight mass spectrometer constructed by W. C. Wiley, I. H. McLaren, and D. B. Harrington. This unique gas chromatography/mass spectrometry (GC/MS) instrument generated mass spectra at a lo-kHz rate for display on an oscilloscope; eluted gas chromate graphic components, such as methanol, acetone, benzene, toluene, and carbon tetrachloride, could be visually identified immediately from the oscilloscope display. Many years of further research and development in many laboratories worldwide were necessary, however, to make continuous on-line GC/MS the uniquely valuable analytical tool that it is today.  相似文献   

8.
9.
The incorporation of stable isotopes improves the assessment of glucose metabolism and, with some researchers using two tracers, (2)H-glucose assessed by gas chromatography/mass spectrometry (GC/MS) and (13)C-glucose by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS), a common derivative for both is advantageous. The most commonly used derivatives for GC/MS are inappropriate for GC/C/IRMS as additional functional groups dilute the label. We therefore considered the suitability of six derivatives for both GC/MS and GC/C/IRMS. Glucose alkylboronates were prepared by adding the appropriate alkylboronic acid (butyl- or methylboronic acid) in pyridine to desiccated glucose. The derivatisation was completed by reacting this with either (a) acetic anhydride or trifluoroacetic anhydride (acetate derivatives) or (b) bis(trimethylsilyl)trifluoroacetamide BSTFA (TMS derivatives). All six derivatives were assessed using GC/MS and (13)C GC/C/IRMS.Neither TMS derivative exhibited any signal intensity in the molecular ion, although a M-15 ion showed good agreement between experimental and theoretical data and, whilst still low in intensity, could be suitable for isotope work. Similarly, none of the acetate derivatives showed any intensity at the molecular ion although three key fragmentation series were identified. The most attractive sequence, initiated by the loss of 1,2 cyclic boronate, resulted in the main fragment ion of interest, m/z 240, corresponding to the fluorinated methylboronate derivate. Minimal carbon and hydrogen atoms are added to this derivative making it an excellent choice for stable isotope work, while proving suitable for analysis by both GC/MS and GC/C/IRMS.  相似文献   

10.
In the present study we developed and validated a liquid chromatography/tandem mass spectrometry (LC‐MS/MS) assay for the determination of flucloxacillin in human plasma and microdialysis samples and cloxacillin in microdialysis samples, using oxacillin as the internal standard for the assay. The samples were separated on a UPLC BEH C18,1.7 µm column (2.1 × 50 mm) and analyzed by a tandem–quadrupole mass spectrometer in multiple reaction monitoring mode using an electronspray ionization interface. For flucloxacillin the method was demonstrated to be accurate and precise in the linearity range of 1–30 mg/L in plasma and 0.05–5.0 mg/L for microdialysate with a regression coefficient (r) of 0.9986 and 0.9989 in plasma and microdialysate respectively. For cloxacillin it was accurate and precise in the range of 0.1–5.0 mg/L for microdialysate with a regression coefficient of 0.9972. The method presents a high sensitivity for flucloxacillin (lower limit of quantification of 1 mg/L for plasma and 0.05 mg/L for microdialysis samples) combined with a low within‐ and between‐day variation (<5.0% for flucloxacillin and cloxacillin in microdialysis samples and <6.5% for plasma samples of flucloxacillin). The validation experiments for the microdialysis probes showed a relative recovery of 85.5% for flucloxacillin at a flow rate of 1.0 μL/min. The results justify the use of this assay for clinical studies for measuring free unbound tissue concentrations of flucloxacillin in patients with a Staphylococcus aureus bacteremia. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
A headspace gas chromatography/mass spectrometry method was developed and validated in-house for the determination of furan in foods. The method of standard additions with d4-furan as the internal standard was used to quantitate furan. The limit of detection and limit of quantitation (LOQ) values ranged from 0.2 and 0.6 nglg, respectively, in apple juice to 0.9 and 2.9 ng/g, respectively, in peanut butter. Recoveries were obtained at 0.5, 1, 2, and 3 times the LOQ. At 1, 2, and 3 times the LOQ, the recoveries ranged from 89.4 to 108%, and the relative standard deviations ranged from 3.3 to 17.3% for all the matrixes. For apple juice, chicken broth, and infant formula, the averaged coefficients of determination from the linear regression analyses were >0.99 with each food fortified at 0.5, 1, 2, and 3 times the LOQ. The coefficients of determination were >0.99 for green beans and 0.96 for peanut butter with the foods fortified at 1, 2, and 3 times the LOQ. Within-laboratory precision was determined by comparing the amounts of furan found in 18 samples by 2 analysts on different days with different instruments. For most of the foods, the difference between the amounts found by each analyst was <18%. The method was used to conduct a survey of >300 foods. The furan levels found ranged from none detected to 174 ng/g.  相似文献   

12.
A fast, sensitive, and accurate GC/MS method for the quantification of aliphatic nitroesters (ethylene glycol dinitrate, nitroglycerin, and triethylene glycol dinitrate) and aromatic amines (diphenylamine, 2-nitrodiphenylamine, and triphenylamine) in propellants was developed and validated. This method comprises a Soxhlet extraction step with dichloromethane, followed by separation on a capillary column MDN-5. Ionization of the analytes is carried out using electron ionization. The limit of quantification of the method was 1% w/w for aliphatic nitroesters and 0.1% w/w for aromatic amines (diphenylamine and triphenylamine). Values of repeatability and reproducibility for analyzed compounds were smaller than values of the maximum allowed tolerances of the Horwitz-equation RSD(max) and 2/3 RSD(max). Values of accuracy for selected compounds were below the acceptable threshold of 15% for all tested levels in the range of calibration curve excepting the lowest concentration of calibration curve for nitroglycerin and aromatic amines. During the validation of method, temperature instability in injection port of gas chromatograph and column was observed for 2-nitrodiphenylamine. Hence, it follows worse results of accuracy and linearity and 2-nitrodiphenylamine was not validated successfully.  相似文献   

13.
A pyrolyzer gas chromatography/mass spectrometry (GC/MS) method eliminates toxic solvents that burden our environment and can address the crucial problem of the solvent extraction GC/MS method. The purpose of this study is to establish an efficient quantitative analysis method for 10 phthalates that are regulated by the several governments. A change of concentrations over time for phthalates and internal standards was measured to verify the feasibility of using an auto sampler that facilitates analyzing multiple samples. Both standards maintained constant concentrations over the appropriate time for analysis. A certified reference material under the auspices of the Korea Research Institute of Standards and Science was used to verify the calibration curve obtained by the pyrolyzer GC/MS method, and a deviation was considered similar to the solvent extraction GC/MS method. Then, the limit of detection and limit of quantitation values were confirmed for various consumer products. To verify the reliability of the method, a comparative test with several accredited testing institutes was conducted, and the results were within the standard deviations of the results provided by the institutes. These results indicate that the pyrolyzer GC/MS method can be used in not only screening but also in accurate quantitative analysis.  相似文献   

14.
A multiresidue method for determining more than 70 pesticides in air has been validated using a single injection with gas chromatography/tandem mass spectrometry (GC/MS/MS). The method validation considered both stages of sampling and analysis. The sampling method, based on active sampling using sorption in sorbent cartidges, was validated by generating standard atmospheres. Performance parameters of the method were evaluated, with a reduction in the limits of quantification by injecting a higher volume of sample extract, and increase of selectivity by the use of MS/MS detection mode. The method was based on solid-phase extraction, which permits a degree of automation. The best adsorbents were found to be Chromosorb 106 and Tenax TA. The retention capacity of these sampling sorbents allows up to 1440 L of air to be sampled without any breakthrough for most of the compounds. Data were generated for assessing the potential exposure of bystanders. The application of the method to the analysis of the air in urban locations near agricultural areas showed that pesticides were present in most of the samples.  相似文献   

15.
The retention and the separation of the enantiomers of 1-phenylpropanol (1PP), 2-phenylpropanol (2PP), and 3-chloro-1-phenylpropanol (3CPP) on silica-bonded quinidine carbamate under normal phase HPLC conditions were investigated. A relatively high selectivity of the stationary phase for 3CPP and 1PP (alpha approximately 1.07-1.09) was achieved with eluents containing ethyl acetate as the polar modifier. These mobile phases were examined in detail. Based on the set of chromatographic and thermodynamic data collected, conclusions regarding the mechanism of enantioselectivity and the structure of the selector chiral center are made.  相似文献   

16.
An accurate method for the quantification of carboxymethyllysine (CML) in food samples is evaluated. CML, a stable advanced Maillard compound, is considered as an useful marker of protein damage in severely heated foods. The proposed GC-MS method stipulates double derivatisation of amino acids and quantification by selected ion monitoring. Relative error of repeatability was further improved from 5 to 1% by replacing internal standard by isotope dilution. Comparison with enzyme linked immunosorbent assay (ELISA) was performed on infant formulas, with satisfactory results in powdered but not in liquid formulas. Quantification of CML in several food matrices allowed evidencing CML formation in food products containing reducing sugar only.  相似文献   

17.
In this study, a new method for the determination of 12 nitroimidazoles and their hydroxymetabolites (metronidazole, hydroxymetronidazole, dimetridazole, ronidazole, hydroxydimetridazole, ipronidazole, hydroxyipronidazole, carnidazole, ornidazole, secnidazole, ternidazole, tinidazole) in beeswax has been developed and validated. The optimized sample preparation procedure included melting and dilution of beeswax in a mixture of n‐hexane and isopropanol followed by extraction with 2% acetic acid. The extracts were purified on strong cation exchange based solid‐phase extraction cartridges and evaporated in a vacuum system with vortex motion. The separation and detection of the nitroimidazoles in the beeswax extracts were achieved within 12 min by liquid chromatography tandem mass spectrometry using a pentafluorophenyl analytical column and applying a gradient elution with acetonitrile and 0.01% acetic acid as mobile phases. The method performance characteristics were evaluated at three concentration levels (1, 2, and 5 μg/kg) and the method was found to be suitable for determination of all tested nitroimidazoles. The limits of detection and quantification were 0.2–0.5 and 0.5–1 μg/kg, respectively. The recoveries varied from 71.2 to 104.9% while the relative standard deviations were less than 13.8% under the intermediate precision conditions.  相似文献   

18.
An analytical method based on thermal desorption (TD) coupled to gas chromatography (GC) and mass spectrometry detection (MS) has been developed and validated for the determination of a wide range of odor nuisance and air-quality volatile organic compounds (VOC) in air. New generation isocyanates, isocyanato- and isothiocyanatocyclohexane, have been included for the first time as target compounds due to their high occurrence in air samples. A dynamic air sampling method to trap gas and vapor on multi-sorbent tubes using portable pump equipment has been also developed. Sorbent tubes were filled with Carbotrap (70mg), Carbopack X (100mg) and Carboxen-569 (90mg). Validation of the TD-GC-MS method showed good selectivity, sensibility and precision according to Compendium Method TO-17 (US Environment Protection Agency) criteria. Limits of detection (signal-to-noise=3, ng in tube) ranges were 0.004-0.03ng (alcanes), 0.001-0.1ng (aromatics), 0.03-14ng (aldehydes), 0.003-7ng (alcohols), 0.003-0.04ng (chlorides), 0.02-0.5ng (esters), 0.002-0.1ng (ketones), 0.01-0.53ng (terpenes), 14-97ng (amides), 0.2-10ng (isocyanates) and 0.001ng (carbon disulfide). The linear dynamic range was over 3-5 orders of magnitude, depending of the VOC. TD-GC-MS analysis was reproducible, with relative standard deviation (n=5) within 20%. VOCs breakthrough examination showed no significant losses when about 2000ng standard was prepared. In order to evaluate the performance of the developed method on real samples, several industrial and urban air samples were analysed. VOCs were found to be stable on the sorbent tubes for at least 1 week when stored at 4 degrees C.  相似文献   

19.
The determination of tetra- to octachlorodibenzo-p-dioxins and tetra- to octachlorodibenzofurans (PCCD/Fs) by high-resolution gas chromatography/tandem mass spectrometry (HRGC/MS/MS) and high-resolution gas chromatography/triple mass spectrometry (HRGC/MS(3)) in a quadrupole ion trap, equipped with an external ion source, is presented. MS/MS involves a typical four-step process, namely ionization, parent ion isolation, collision-induced dissociation (CID) and mass analysis of the daughter ions. For the MS(3) experiment, the MS/MS scan function is used with the addition of selected daughter ion isolation, their CID and the mass analysis of second-generation product ions called 'grand-daughter ions.' For both methods, the energies necessary for the CID of the 17 PCDD/Fs were determined and optimized using multiple scan functions with different CID amplitudes. The CID efficiency, defined as the signal ratio of fragment ions detected from the major dissociation channels to molecular ions isolated, was 1.15-2.40 V for parent ion dissociation (MS/MS) and 1.05-1.50 V for daughter ion dissociation (MS(3)) and for all the chloro congeners. The same sensitivity (1 pg microl(-1)) can be reached with both the MS/MS and MS(3) methods and linear responses were obtained between 1 and 100 pg microl(-1) injected.  相似文献   

20.
The photostability of guaiazulene (1,4-dimethyl-7-isopropylazulene; GA), a natural azulenic compound used in cosmetic and health-care products, as well as in pharmaceutical preparations, was investigated in solution (methanol, ethanol, acetonitrile), by different techniques: gas chromatography/mass spectrometry (GC/MS) and high-performance liquid chromatography combined with atmospheric pressure chemical ionization mass spectrometry and UV detection (LC/APCI-MS and HPLC/UV). A solar simulator (xenon-arc lamp) was used as UV-A radiation source. The study involved: monitoring compound decomposition, identifying products of photodegradation (PPs), assessing the role of oxygen and evaluating the kinetics of the process. Minor PPs are volatile compounds and were characterized by GC/MS, while oligomeric polyoxygenated compounds, tentatively characterized on the basis of MS and MS/MS spectra, were found to be the main photoproducts. The photodegradation was found to be enhanced by the presence of oxygen; nevertheless, determination of the singlet oxygen quantum yield for GA gave a lower value than that for the reference standard Rose Bengal. The obtained results and the developed stability-indicating methods (GC/MS and LC/MS) are of interest for stability studies and/or quality control purposes of GA as raw material or cosmetic products.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号