首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Venturi easy ambient sonic spray ionization mass spectrometry in both its liquid (VL‐EASI‐MS) and solid sample modes (VS‐EASI‐MS) is shown to provide nearly immediate and secure typification of woods, as demonstrated for Mahogany, an endangered and most valuable type of tropical wood. This reddish wood displays unique phytochemical markers (phragmalin‐type limonoids) which are rapidly detected from the wood surface by VS‐EASI‐MS or from a simple methanol extract of a tiny wood chip by VL‐EASI‐MS. Unique profiles were obtained for Mahogany (Swietenia macrophylla) whereas genuine samples of six other similar types of woods, which are commonly falsified by artificial coloring and commercialized as Mahogany, display also typical but dissimilar pythochemical profiles as compared to that of the authentic wood. Variable and atypical chemical profiles were observed for artificially colored woods. Secure chemical characterization via VS‐EASI‐MS or Vs‐EASI‐MS fingerprints of Mahogany and other types of woods with similar appearance should help to control the illegal logging and trade of this and other endangered woods and their falsification, and to create certified standards. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
Recently, 3‐nitrobenzonitrile (3‐NBN) has been used to improve sensitivity of sonic‐spray ionization mass spectrometry. Easy ambient sonic‐spray ionization (EASI) is one of the simplest, gentlest and most used spray‐based desorption/ionization ambient techniques, but limited sensitivity has been commonly taken as its major drawback. Herein we investigate the use of 3‐NBN as a dopant in EASI‐MS for improved sensitivity. Using a few typical EASI samples as test cases, the presence of 10 ppm (µg ml?1) of 3‐NBN in the spray solvent showed two to fourfold gains in EASI‐MS sensitivity as measured both by total ion current and S/N ratios, accompanied with significant reductions in chemical noise. Sensitivity for DESI using 3‐NBN as a dopant also improved and dopant DESI versus dopant EASI sensitivities were compared. The use of solvent dopants seems therefore to be a promising strategy to improve sensitivity for spray‐based ambient MS techniques. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

3.
Using enalapril maleate as a test case, the ability of ambient mass spectrometry, namely, via easy ambient sonic‐spray ionization mass spectrometry (EASI‐MS), to perform direct monitoring of drug degradation has been tested. Two manufacturing processes were investigated (direct compression and wet granulation), and the formation of degradation products was measured via both EASI‐MS and high‐performance liquid chromatography with ultraviolet detection for a total period of 18 months. Both techniques provide comparable results, which indicate that direct analysis by ambient mass spectrometric techniques presents a viable alternative for drug degradation monitoring with superior simplicity, throughput, and reliability (no sample manipulation), and comparable quantitative results. In terms of qualitative monitoring, the full mass spectra with intact species provided by EASI‐MS allow for comprehensive monitoring of known and unknown (or unexpected) degradation products. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
Desorption electrospray ionization mass spectrometry (DESI‐MS) and easy ambient sonic‐spray ionization mass spectrometry (EASI‐MS) are employed here in the forensic analysis of chemical compounds found in condoms and relative traces, and their analytical performances are compared. Statistical analysis of data obtained from mass spectra only was applied in order to obtain classification rules for distinguishing ten types of condoms. In particular, two supervised chemometric techniques [linear discriminant analysis (LDA) and soft independent modeling of class analogy (SIMCA)] were carried out on absolute and relative intensity values to test the performances of statistical models in terms of predictive capacity. The achieved classification of samples was excellent because of the high prediction percentages of the method used both for DESI and EASI mass spectrometry analyses, confirming these two as potential ambient ionization techniques for forensic analyses in case of sexual assault crimes. EASI‐MS showed 99% prediction ability for LDA using relative data and 100% prediction ability for SIMCA using both absolute and relative ones, while DESI showed 94% prediction ability for both LDA and SIMCA. The absence of any sample preparation technique gives advantages in terms of sample preservation and reduced contamination, allowing successive analyses to be performed on the same sample by other techniques. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
The increasing number of new psychoactive substances (NPS) and their quick worldwide spreading, often only slightly modified in the form of new derivatives and analogues, have brought the need for fast, wide‐ranging, and unequivocal identification methods in clinical and forensic investigations. Because it usually provides secure results, gas chromatography coupled to mass spectrometry (GC‐MS) has been routinely employed as the standard technique for the detection of NPS in blotter papers. For 25I‐NBOH (N‐(2‐hydroxybenzyl)‐2‐(4‐iodo‐2,5‐dimethoxyphenyl)ethan‐1‐aminium), however, GC‐MS analysis of an blotter paper extract leads to incorrect results. In this work, we investigated whether easy ambient sonic‐spray mass spectrometry imaging (EASI‐IMS), and ambient ionization MS method can be applied directly to the surface of the sample requiring therefore no extraction or sample preparations, would serve as an efficient, sensitive, and secure alternative for 25I‐NBOH screening.  相似文献   

6.
Easy ambient sonic spray ionization (EASI) and desorption electrospray ionization (DESI) were used for imaging of a number of samples, including sections of rat brain and imprints of plant material on porous Teflon. A novel approach termed Displaced Dual-mode Imaging was utilized for the direct comparison of the two methods: Images were recorded with the individual rows alternating between EASI and DESI, yielding a separate image for each technique recorded under perfectly similar conditions on the same sample. EASI works reliably for imaging of all samples, but the choice of spray solvent and flow rate is more critical in tissue imaging with EASI than with DESI. The overall sensitivity of EASI is, in general, slightly lower than that of DESI, and the representation of the dynamic range is different in images of the two techniques for some samples. However, for abundant compounds, EASI works well, resulting in images of similar quality as DESI. EASI can thus be used in imaging experiments where the application of high voltage is impractical or undesirable. The present study is in its nature also a comparison of the characteristics of the two techniques, showing results also applicable for non-imaging work, with regards to sensitivity and experimental conditions.  相似文献   

7.
Perfume counterfeiting is an illegal worldwide practice that involves huge economic losses and potential consumer risk. EASI is a simple, easily performed and rapidly implemented desorption/ionization technique for ambient mass spectrometry (MS). Herein we demonstrate that EASI-MS allows nearly instantaneous perfume typification and counterfeit detection. Samples are simply sprayed onto a glass rod or paper surface and, after a few seconds of ambient drying, a profile of the most polar components of the perfume is acquired. These components provide unique and reproducible chemical signatures for authentic perfume samples. Counterfeiting is readily recognized since the exact set and relative proportions of the more polar chemicals, sometimes at low concentrations, are unknown or hard to reproduce by the counterfeiters and hence very distinct and variable EASI-MS profiles are observed for the counterfeit samples.  相似文献   

8.
We have studied the potential degradation of poly(lactic acid)-based fabrics treated with commercial softeners and stored under two sets of conditions for one year. Initial wet-processing caused a fall in molecular weight of about 28%, irrespective of after-treatment. Storage at 40 °C and 80% RH produced further degradation which, with few exceptions, was aggravated by the presence of softeners. Ultimately, all samples degraded beyond the point of commercial usefulness. No clear distinction could be made between the effects of softeners having differing compositions. In contrast, fabrics stored under milder conditions of 23 °C and 50% RH showed no significant time-dependent polymer degradation, irrespective of the treatment applied. There were slight changes in tensile properties and some evidence of physical structural effects having occurred, which we attribute to physical aging. However, we do not believe these to be so serious as to call into question the long-term viability of PLA-based textile products.  相似文献   

9.
Direct Analysis in Real Time (DART) is an ambient ionization technique for mass spectrometry that provides rapid and sensitive analyses with little or no sample preparation. DART has been reported primarily for mass analyzers of low to moderate resolving power such as quadrupole ion traps and time‐of‐flight (TOF) mass spectrometers. In the current work, a custom‐built DART source has been successfully coupled to two different Fourier transform ion cyclotron resonance (FT‐ICR) mass spectrometers for the first time. Comparison of spectra of the isobaric compounds, diisopropyl methylphosphonate and theophylline, acquired by 4.7 T FT‐ICR MS and TOF MS, demonstrates that the TOF resolving power can be insufficient for compositionally complex samples. 9.4 T FT‐ICR MS yielded the highest mass resolving power yet reported with DART ionization for 1,2‐benzanthracene and 9,10‐diphenylanthracene. Polycyclic aromatic hydrocarbons exhibit a spatial dependence in ionization mechanisms between the DART source and the mass spectrometer. The feasibility of analyzing a variety of samples was established with the introduction and analysis of food products and crude oil samples. DART FT‐ICR MS provides complex sample analysis that is rapid, highly selective and information‐rich, but limited to relatively low‐mass analytes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
The appearance of pyrazolam in Internet shops selling ‘research chemicals’ in 2012 marked the beginning of designer benzodiazepines being sold as recreational drugs or ‘self medication’. With recent changes in national narcotics laws in many countries, where two uncontrolled benzodiazepines (phenazepam and etizolam), which were marketed by pharmaceutical companies in some countries, were scheduled, clandestine laboratories seem to turn to poorly characterized research drug candidates as legal substitutes. Following the appearance of pyrazolam, it comes with no surprise that recently, flubromazepam (7‐bromo‐5‐(2‐fluorophenyl)‐1,3‐dihydro‐2H‐1,4‐benzodiazepin‐2‐one), a second designer benzodiazepine, was offered on the market. In this article, this new compound was characterized using nuclear magnetic resonance, gas chromatography‐mass spectrometry (GC–MS), liquid chromatography–mass spectrometry (LC–MS/MS) and liquid chromatography quadrupole time‐of‐flight MS (LC–Q–ToF–MS). Additionally, a study was carried out, in which one of the authors consumed 4 mg of flubromazepam to gain preliminary data on the pharmacokinetic properties and the metabolism of this compound. For this purpose, serum as well as urine samples were collected for up to 31 days post‐ingestion and analyzed applying LC–MS/MS and LC–Q‐ToF‐MS techniques. On the basis of this study, flubromazepam appears to have an extremely long elimination half‐life of more than 100 h. One monohydroxylated compound and the debrominated compound could be identified as the predominant metabolites, the first allowing a detection of a consumption for up to 28 days post‐ingestion when analyzing urine samples in our case. Additionally, various immunochemical assays were evaluated, showing that the cross‐reactivity of the used assay seems not to be sufficient for safe detection of the applied dose in urine samples, bearing the risk that it could be misused in drug‐withdrawal settings or in other circumstances requiring regular drug testing. Furthermore, it may be used in drug‐facilitated crimes without being detected. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
Urinary 8‐oxo‐7,8‐dihydro‐2′‐deoxyguanosine (8‐oxodG) represents a non‐invasive biomarker for oxidative stress and may be useful for monitoring chemotherapeutic and chemopreventive interventions associated with cancer‐related alterations in oxidative stress. We describe the development and validation of two separate liquid chromatography/tandem mass spectrometry (LC/MS/MS) selected reaction monitoring (SRM) methods for the determination of 8‐oxodG and creatinine in both murine and human urine using stable isotope labelled internal standards. Levels of 8‐oxodG were normalised to creatinine. The LC/MS/MS methods were applied to two chemoprevention studies utilising tea polyphenols in humans and TRAMP (TRansgenic Adenocarcinoma of the Mouse Prostate) mice. Patients with benign prostatic hyperplasia received 1 g/day of green tea polyphenols (GTP), 1 g/day of black tea theaflavins (BTT) or no treatment for 4 weeks. TRAMP mice received GTP (0.05% in drinking water) for 4 or 25 weeks. Prostate pathology in TRAMP mice was not affected by GTP. Levels of 8‐oxodG were not altered by tea polyphenols in either mice or humans. In TRAMP mice, urinary 8‐oxodG levels were elevated with increasing age (p < 0.0001) but not changed by the presence of prostate tumours. In conclusion, the LC/MS/MS SRM methods described here are ideally suited for the accurate determination of 8‐oxodG and creatinine in urine samples from both clinical and pre‐clinical studies. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

12.
A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography–tandem mass spectrometry (LC‐MS/MS) was developed. This assay represents the first LC‐MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3‐atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/mL and 10 nm for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3–900 ng/mL and 10 nm to 10 µm for human plasma and cellular samples, respectively (r2 > 0.999). The intra‐ and inter‐day assay accuracy and precision were evaluated using quality control samples at three different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect and recovery were also successfully demonstrated. The present assay is superior to previously published LC‐MS and LC‐MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
A novel drug‐screening system, consisting of paper spray‐MS (PS‐MS) and a CE‐ESI‐MS method was developed. This system can be easily switched either to PS‐MS for rapidly screening samples or to the traditional CE‐ESI‐MS method for separation and to obtain detailed mass spectral information, while sharing the same mass spectrometer. In the former case, when a sharp (15°‐tip) chromatography paper was used, the optimized distance from the paper tip to the mass inlet was 7.7 mm, whereas the optimized distance for the CE‐ESI tip was ~13.5 mm. Using 4chloroamphetamine as a model compound, the LODs for PS‐MS and CE‐ESI‐MS were determined to ~0.1 and 0.25 ppm, respectively. Comparisons of results obtained using PS‐MS and CE‐ESI‐MS and the experimental conditions are described.  相似文献   

14.
Atenolol, nadolol, metoprolol, bisoprolol and betaxolol were simultaneously determined in groundwater samples by large‐volume injection coupled‐column reversed‐phase liquid chromatography with fluorescence detection (LVI‐LC‐LC‐FD) and liquid chromatography‐time‐of‐flight mass spectrometry (LC‐TOF‐MS). The LVI‐LC‐LC‐FD method combines analyte isolation, preconcentration and determination into a single step. Significant reductions in costs for sample pre‐treatment (solvent and solid phases for clean up) and method development times are also achieved. Using LC‐TOF‐MS, accurate mass measurements within 3 ppm error were obtained for all of the β‐blockers studied. Empirical formula information can be obtained by this method, allowing the unequivocal identification of the target compounds in the samples. To increase the sensitivity, a solid‐phase extraction step with Oasis MCX cartridge was carried out yielding recoveries of 79–114% (n=5) with RSD 2–7% for the LC‐TOF‐MS method. SPE gives a high purification of β‐blockers compared with the existing methods. A 100% methanol wash was allowed for these compounds with no loss of analytes. Limit of quantification was 1–7 ng/L for LVI‐LC‐LC‐FD and 0.25–5 ng/L for LC‐TOF‐MS. As a result of selective extraction and effective removal of coextractives, no matrix effect was observed in LVI‐LC‐LC‐FD and LC‐TOF‐MS analyses. The methods were applied to detect and quantify β‐blockers in groundwater samples of Almería (Spain).  相似文献   

15.
In this study, different electrospray ionization mass spectrometric (ESI‐MS) methods were utilized to analyze several pairs of taxane stereoisomers including paclitaxel and 7‐epi‐paclitaxel. Both ESI‐MS and tandem mass spectrometry (MS/MS) techniques provided stereochemically dependent mass spectra in negative‐ion mode, and all studied stereoisomers could be easily distinguished based on their characteristic ions or distinct fragmentation patterns. MS/MS experiments for several taxane analogues at various collision energies were performed to elucidate potential dissociation pathways. The gas‐phase deprotonation potentials were also calculated to estimate the most thermodynamically favorable deprotonation site using DFT B3LYP/6‐31G(d). The results of the theoretical studies agreed well with the fragmentation patterns of paclitaxel and 7‐epi‐paclitaxel observed from MS/MS experiments. In addition, it was found that liquid chromatography (LC)/ESI‐MS was a useful and sensitive technique for assignment of C‐7 taxane stereoisomers from realistic samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
A liquid chromatography–triple quadrupole mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of 5‐nitro‐5′‐hydroxy‐indirubin‐3′‐oxime (AGM‐130) in human plasma to support a microdose clinical trial. The method consisted of a liquid–liquid extraction for sample preparation and LC‐MS/MS analysis in the positive ion mode using TurboIonSprayTM for analysis. d3‐AGM‐130 was used as the internal standard. A linear regression (weighted 1/concentration) was used to fit calibration curves over the concentration range of 10–2000 pg/mL for AGM‐130. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 96.6% with a precision (coefficient of variation, CV) of 4.4%. For quality control samples at 30, 160 and 1600 pg/mL, the between run CV was ≤5.0 %. Between‐run accuracy ranged from 98.1 to 101.0%. AGM‐130 was stable in 50% acetonitrile for 168 h at 4°C and 6 h at room temperature. AGM‐130 was also stable in human plasma at room temperature for 6 h and through three freeze–thaw cycles. The variability of selected samples for the incurred sample reanalysis was ≤12.7% when compared with the original sample concentrations. This validated LC‐MS/MS method for determination of AGM‐130 was used to support a phase 0 microdose clinical trial. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
The capabilities of a high‐resolution (HR), accurate mass spectrometer (Exactive‐MS) operating in full scan MS mode was investigated for the quantitative LC/MS analysis of drugs in patients' plasma samples. A mass resolution of 50 000 (FWHM) at m/z 200 and a mass extracted window of 5 ppm around the theoretical m/z of each analyte were used to construct chromatograms for quantitation. The quantitative performance of the Exactive‐MS was compared with that of a triple quadrupole mass spectrometer (TQ‐MS), TSQ Quantum Discovery or Quantum Ultra, operating in the conventional selected reaction monitoring (SRM) mode. The study consisted of 17 therapeutic drugs including 8 antifungal agents (anidulafungin, caspofungin, fluconazole, itraconazole, hydroxyitraconazole posaconazole, voriconazole and voriconazole‐N‐oxide), 4 immunosuppressants (ciclosporine, everolimus, sirolimus and tacrolimus) and 5 protein kinase inhibitors (dasatinib, imatinib, nilotinib, sorafenib and sunitinib). The quantitative results obtained with HR‐MS acquisition show comparable detection specificity, assay precision, accuracy, linearity and sensitivity to SRM acquisition. Importantly, HR‐MS offers several benefits over TQ‐MS technology: absence of SRM optimization, time saving when changing the analysis from one MS to another, more complete information of what is in the samples and easier troubleshooting. Our work demonstrates that U/HPLC coupled to Exactive HR‐MS delivers comparable results to TQ‐MS in routine quantitative drug analyses. Considering the advantages of HR‐MS, these results suggest that, in the near future, there should be a shift in how routine quantitative analyses of small molecules, particularly for therapeutic drugs, are performed. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
For sample assay to support global clinical studies of perampanel, a novel AMPA receptor antagonist, six chromatographic assay methods in human plasma were developed and fully validated at each laboratory using liquid chromatography with tandem mass spectrometry (LC‐MS/MS) or LC with fluorescence detection (LC‐FL). In this study, samples fortified with known perampanel concentrations were assayed at six laboratories to find whether assay data are comparable. Perampanel was extracted by protein precipitation or liquid–liquid extraction, chromatographed on a reverse‐phase column then detected by MS/MS or FL to achieve the limit of quantification of 0.25 or 1 ng/mL. Cross‐validation samples at four concentrations prepared at a central laboratory were determined at six laboratories and the mean accuracy at each concentration was within ±15% except the low concentration at one laboratory (relative error ?17.4%), suggesting that plasma concentrations of perampanel in clinical trials can be compared across laboratories.  相似文献   

19.
Desorption atmospheric pressure photoionization‐mass spectrometry (DAPPI‐MS) is a versatile surface analysis technique for a wide range of analytes, especially for neutral and non‐polar analytes. Here, a set of analytes typically found in environmental or food samples was analyzed by DAPPI‐MS. The set included five polyaromatic hydrocarbons (PAHs), one N‐PAH, one brominated flame retardant, and nine pesticides, which were studied with three different spray solvents: acetone and toluene in positive ion mode, and anisole in negative ion mode. The analytes showed [M + H]+, M+?, and [M–H]? ions as well as fragmentation and substitution products. Detection limits for the studied compounds ranged from 30 pg to 1 ng (from 0.14 to 5.6 pmol). To demonstrate the feasibility of the use of DAPPI‐MS two authentic samples – a circuit board and orange peel – and a spiked soil sample were analyzed. Tetrabromobisphenol A, imazalil, and PAHs were observed from the three above‐mentioned samples, respectively. The method is best suited for rapid screening analysis of environmental or food samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
An accurate and precise method for the quantification of 11‐nor‐Δ9‐tetrahydrocannabinol‐9‐carboxylic acid (THCA) in urine by liquid chromatography/tandem mass spectrometry (LC/MS/MS) for doping analysis purposes has been developed. The method involves the use of only 200 µL of urine and the use of D9‐THCA as internal standard. No extraction procedure is used. The urine samples are hydrolysed using sodium hydroxide and diluted with a mixture of methanol/glacial acetic acid (1:1). Chromatographic separation is achieved using a C8 column with gradient elution. All MS and MS/MS parameters were optimised in both positive and negative electrospray ionisation modes. For the identification and the quantification of THCA three product ions are monitored in both ionisation modes. The method is linear over the studied range (5–40 ng/mL), with satisfactory intra‐and inter‐assay precision, and the relative standard deviations (RSDs) are lower than 15%. Good accuracy is achieved with bias less than 10% at all levels tested. No significant matrix effects are observed. The selectivity and specificity are satisfactory, and no interferences are detected. The LC/MS/MS method was applied for the analysis of 48 real urine samples previously analysed with a routine gas chromatography/mass spectrometry (GC/MS) method. A good correlation between the two methods was obtained (r2 > 0.98) with a slope close to 1. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号