共查询到20条相似文献,搜索用时 15 毫秒
1.
从理论上讲, 离子阱质谱仪的性能是由阱内电场分布决定的,而电场分布又是由组成离子阱的电极几何结构和离子阱工作电压决定的. 对于矩形离子阱, 即使不考虑其几何结构的偏差, 其阱内的电场分布一般也很复杂. 在矩形离子阱内, 除四极电场外, 还包含多种成分的其他各种高阶场, 它们直接影响离子在阱内的运动轨迹和离子阱质谱的性能. 由于各种电场成分对离子阱内离子运动的影响非常复杂, 还很难从数学上给出精确的解析解, 使得目前从理论上还无法预测高阶场成分对质谱性能的影响. 本工作通过测定不同几何结构的矩形离子阱的稳定图, 从实验上比较了不同场半径, 即不同电场分布条件下的离子阱质谱性能的差别. 实验中, 通过改变离子阱的几何比例结构, 详细测定了不同结构的矩形离子阱的稳定图特征, 并与实验测得的质谱分析结果进行比较. 同时, 我们还详细介绍了矩形离子阱质谱的稳定图的测定方法, 并根据得到的不同情况下的稳定图结构分析了离子阱的质谱性能. 研究结果表明: 可以通过比较试验得到的稳定图结构来判断其离子阱质谱仪的性能如质量分辨能力等. 此外, 实验结果还发现: 对于y方向拉伸结构的矩形离子阱, 其实验绘制得到的是不完整的稳定图. 但根据稳定图边界的特点, 通过采用四极直流电压调制的方法, 可以对y方向拉伸结构的矩形离子阱的性能进行改善, 极大地提高了阱的质量分辨能力. 相似文献
2.
3.
Qingyu Song Wei Xu Scott A. Smith Liang Gao William J. Chappell R. Graham Cooks Zheng Ouyang 《Journal of mass spectrometry : JMS》2010,45(1):26-34
In recent years, it has become increasingly interesting to understand the performance of mass spectrometers at pressures much higher than those employed with conventional operating conditions. This interest has been driven by several influences, including demand for the development of reduced‐power miniature mass spectrometers, desire for improved ion transfer into and through mass spectrometers, enhanced‐yield preparative mass separations, and mass filtering at the atmospheric pressure interface. In this study, an instrument was configured to allow for the performance characterization of a rectilinear ion trap (RIT) at pressures up to 50 mtorr with air used as the buffer gas. The mass analysis efficiency, mass resolution, isolation efficiency, and collision‐induced dissociation (CID) efficiency were evaluated at pressures ranging from 1 to 50 mtorr. The extent of degradation of mass resolution, isolation efficiency and ion stability as functions of pressure were characterized. Also, the optimal resonance ejection conditions were obtained at various pressures. Operations at 50 mtorr demonstrated improved CID efficiency in addition to peak widths of 2 and 5 m/z units (full width at half‐maximum, FWHM) for protonated caffeine (m/z 195) and Ultramark (m/z 1521) respectively. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
4.
A comprehensive study on the fragmentation pattern of the antimicrobial growth promoter avilamycin A was conducted in a quadrupole ion trap mass spectrometer equipped with an electrospray ionization (ESI) source. Performing multiple-stage experiments on the deprotonated molecule (m/z 1401) and its principal product ions showed that a sequential shortening of the oligosaccharide backbone took place, which can be attributed to the localization of the negative charge in the terminal dichloroisoeverninic acid. Under (+)-ESI conditions, avilamycin A readily formed an intense sodium-cationized molecule, [M + Na](+) (m/z 1425). Structural elucidation of the second-, third- and fourth-generation fragment ions revealed that all of the structures shared a common molecular portion comprising a central monosaccharide. This observation allowed us to assign confidently the complexation site of the alkali metal cation. In addition to the monosodiated molecule, the full-scan mass spectral acquisition also yielded a less abundant disodiated molecule, [M - H + 2Na](+) (m/z 1447). Multiple-stage experiments on this ion indicated that the second sodium ion compensates for the negative charge located at either of two positions within the molecule. While deprotonation of the phenolic hydroxyl group in the dichloroisoeverninic acid moiety was suggested to be driven by charge stabilization in the aromatic ring (in analogy with the deprotonated molecule in the (-)-ESI mode), the deprotonation at an alpha-carbon of an ester side-chain substituent in the oligosaccharide part was believed to provide a stable chelation-like coordination site for the cation. 相似文献
5.
6.
The fragmentation of heterocyclic amines (HAs) in an ion trap was studied by means of the infusion of methanolic solutions containing the compounds under assay, and using an atmospheric pressure chemical ionization (APCI) as ion source. The MS(n) spectra obtained for compounds included in the same family, either aminoimidazoazaarenes (AIAs) or carbolines, were compared in order to propose fragmentation pathways for each HA. Moreover, labelled AIAs were used to establish the mechanisms. The protonated molecule was always obtained, but subsequent fragmentation was different for both families. In the case of AIAs, major product ions came from the fragmentation of the aminoimidazole moiety, thus the base peak in MS(2) corresponded to the loss of the methyl group, and losses of C(2)NH(3) and CN(2)H(2) were also observed. Further fragmentation occurred in the heterocyclic rings, mainly with losses of HCN and CH(3)CN. For carbolines, the most important product ions came from the loss of ammonia, except for harman and norharman, the loss of a methyl group for methylated carbolines or the loss of diverse fragments from the heterocyclic rings. In some cases, ion-molecule reactions into the ion trap were observed. For instance, for AalphaC or MeAalphaC one ion originating from these reactions corresponded to the base peak. 相似文献
7.
Due to the varying toxicity the species of organotins in their widespread applications, it is important for analytical methods to address their speciation. Traditional methods call for the hydrolysis and subsequent derivatization of the organotins before analysis. These methods can be time‐consuming, derivatization can be incomplete and high levels of background interference produce difficulties in identification and quantification. The use is described of a non‐derivatization and non‐hydrolysis micro‐liquid chromatography–electrospray/ion trap mass spectrometry for separation and detection of the organotins. Copyright © 1999 John Wiley & Sons, Ltd. 相似文献
8.
Ding L Sudakov M Brancia FL Giles R Kumashiro S 《Journal of mass spectrometry : JMS》2004,39(5):471-484
In a digital ion trap (DIT), the quadrupole trapping and excitation waveforms are generated by the rapid switching between discrete d.c. voltage levels. As the timing of the switch can be controlled precisely by digital circuitry, the approach provides an opportunity to generate mass spectra by means of a frequency scan in contrast to the conventional voltage scan, thus providing a wider mass range of analysis. An instrument has been constructed which employs a 'non-stretched' ion trap and the field fault around the aperture of the end-cap electrode can be corrected electronically using a field-adjusting electrode. The ion trap was coupled with electrospray ionization (ESI) and atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) sources to demonstrate the capability of the digital method. AP-MALDI mass spectra of singly charged ions with mass-to-charge ratios upto 17 000 Th were generated using a trapping voltage of only 1000 V. Forward and reverse mass scans at resolutions up to 19 000 and precursor ion isolation at resolutions up to 3500 with subsequent tandem mass spectrometric analysis were demonstrated. The method of generating the digital waveforms and period scan is described. Discussion of the issues of mass range, scan speed, ion trapping efficiency and collision-induced dissociation efficiency are also provided. 相似文献
9.
Kyuseok Song Hyungki Cha Jongmin Lee Hyunkook Park Sang Chun Lee 《Microchemical Journal》2001,68(2-3)
Laser-ablation ion trap mass spectrometry (LA-ITMS) is applied for the analysis of rare-earth elements in soil samples. The target elements studied in this work were ytterbium (Yb) and samarium (Sm). The isotopic compositions of these elements were analyzed for standard samples with chip shape, the western phosphate rock sample (NIST SRM-694), and soil samples collected near our laboratory. For metal samples of Sm and Yb, isotopes of these elements as well as oxide forms were clearly identified. For the case of soil samples only a tentative assignment on the mass peaks were performed due to the complicated mass spectra that originated from the oxide forms of various rare-earth elements. 相似文献
10.
Characterization of the chemical composition of white chrysanthemum flowers of Hangzhou by using high‐performance ion trap mass spectrometry 下载免费PDF全文
Xiahui Zhou Xiaocheng Chen Xin Wu Gang Cao Junjie Zhang 《Journal of separation science》2016,39(7):1218-1222
In this study, high‐performance liquid chromatography coupled with amaZon SL high‐performance ion trap mass spectrometry was used to analyze the target components in white chrysanthemum flowers of Hangzhou. Twenty‐one components were detected and identified in both white chrysanthemum flowers of Hangzhou samples by using target compound analysis. Furthermore, seven new compounds in white chrysanthemum flowers of Hangzhou were found and identified by analyzing the fragment ion behavior in the mass spectra. The established method can be expedient for the global quality investigation of complex components in herbal medicines and food. 相似文献
11.
The feasibility of experimental design in combination with subsequent response surface modelling was illustrated for the prediction and interpretation of tandem mass spectrometric (MS/MS) fragmentation data using a linear quadrupole ion trap under various experimental conditions. The instrumental parameters included were (i) the pressure of the collision gas, (ii) the collision energy, (iii) the fill time of the linear ion trap and (iv) the scan rate. The spectral intensity and width of five fragment ions of the doubly charged neuro-active peptide bombesin were used for evaluation, and all experiments were performed so as to resemble the results obtained from a liquid chromatographic peak. The reported results show how fairly simple mathematical tools can be utilized successfully to describe fundamental mechanisms associated with multiple collisional activation and collision-induced dissociation processes without an extensively controlled experimental environment. Most beneficial, using the suggested approach, is the ability to study interaction (synergistic) effects between various parameters. As was realized from the results, many interaction effects are indeed significant. For example, the effect on the signal intensity of different collision gas pressure settings is strongly dependent on the settings of the other parameters. The described approach can easily be adopted for optimization purposes of any MS/MS experiment. 相似文献
12.
Optimized precursor ion selection for labile ions in a linear ion trap mass spectrometer and its impact on quantification using selected reaction monitoring 下载免费PDF全文
Hyun‐Seok Lee Kyong‐Oh Shin Sung‐Chan Jo Yong‐Moon Lee Yong‐Hyeon Yim 《Journal of mass spectrometry : JMS》2014,49(12):1234-1238
The fragmentation of fragile ions during the application of an isolation waveform for precursor ion selection and the resulting loss of isolated ion intensity is well‐known in ion trap mass spectrometry (ITMS). To obtain adequate ion intensity in the selected reaction monitoring (SRM) of fragile precursor ions, a wider ion isolation width is required. However, the increased isolation width significantly diminishes the selectivity of the channels chosen for SRM, which is a serious problem for samples with complex matrices. The sensitive and selective quantification of many lipid molecules, including ceramides from real biological samples, using a linear ion trap mass spectrometer is also hindered by the same problem because of the ease of water loss from protonated ceramide ions. In this study, a method for the reliable quantification of ceramides using SRM with near unity precursor ion isolation has been developed for ITMS by utilizing alternative precursor ions generated by in‐source dissociation. The selected precursor ions allow the isolation of ions with unit mass width and the selective analysis of ceramides using SRM with negligible loss of sensitivity. The quantification of C18:0‐, C24:0‐ and C24:1‐ceramides using the present method shows excellent linearity over the concentration ranges from 6 to 100, 25 to 1000 and 25 to 1000 nM, respectively. The limits of detection of C18:0‐, C24:0‐ and C24:1‐ceramides were 0.25, 0.25 and 5 fmol, respectively. The developed method was successfully applied to quantify ceramides in fetal bovine serum. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献
13.
A new tandem mass spectrometry (MS/MS) method based on the use of an ion trap mass spectrometer for the identification and quantitation of F(2)-isoprostanes has been developed. It consists of two solid-phase extractions and two derivation steps followed by gas chromatography/negative ion chemical ionization tandem mass spectrometry (GC/NICI-MS/MS) analysis. This method is highly selective and sensitive and it has been successfully applied to biological samples. 相似文献
14.
Lagarrigue M Bossée A Afonso C Fournier F Bellier B Tabet JC 《Journal of mass spectrometry : JMS》2006,41(8):1073-1085
Complexation by transition metal ions (CuII and FeII) was successfully used to differentiate the diastereomeric YAGFL, YDAGFL and Y(D)AGF(D)L pentapeptides by electrospray ionization-ion trap mass spectrometry in the positive ion mode using low-energy collision conditions. This distinction was allowed by the stereochemical effects due to the (D)Leu/(L)Leu and the (D)Ala/(L)Ala residues yielding various steric interactions which direct relative dissociation rate constants of the binary [(M - H) + MeII]+ complexes (Me = Cu or Fe) subjected to low-energy, collision-induced dissociation processes. The interpretation of the collision-induced dissociation spectra obtained from the diastereomeric cationized peptides allowed the location of the deprotonated site(s), leading to the postulation of ion structures and fragmentation pathways for both the [(M - H) + CuII]+ and [(M - H) + FeII]+ complexes, which differed significantly. With CuII, consecutive fragmentations, initiated by the decarboxylation at C-terminus, were favored relative to sequence product ions. On the other hand, with FeII, competitive fragmentations resulting in abundant sequence product ions and significant internal losses were preferred. This could be explained by different localizations of the negative charge, which directs the orientation of both the [(M - H) + CuII]+ and [(M - H) + FeII]+ binary complexes fragmentations. Indeed, the free negative charge of the [(M - H) + CuII]+ ions was mainly located at one oxygen atom: either at the C-terminal carboxylic group or, to a minor extent, at the Tyr phenol group (i.e. zwitterionic forms). On the other hand, the negative charge of the [(M - H) + FeII]+ ions was mainly located at one of the nitrogen atoms of the peptide backbone and coordinated to FeII (i.e. salt non-zwitterionic form).Moreover, this study reveals the particular behavior of CuII reduced to CuI, which promotes radical losses not observed from the peptide-FeII complexes. Finally, this study shows the analytical potentialities of the complexation of transition metal ions with peptides providing structural information complementary to that obtained from low-energy, collision-induced dissociation processes of protonated or deprotonated peptides. 相似文献
15.
Ion/molecule reactions were explored in a newly developed miniature mass spectrometer fitted with a rectilinear ion trap (RIT) mass analyzer. The tandem mass spectrometry performance of this instrument is demonstrated using collision induced dissociation (CID) and ion/molecule reactions. The latter includes Eberlin transacetalization reactions and electrophilic additions. Selective detection of the chemical warfare simulant dimethyl methyl phosphonate (DMMP) was achieved through selective Eberlin reactions of its characteristic phosphonium fragment ion CH3OP(+)(O)CH3 (m/z 93), with 1,4-dioxane or 1,3-dioxolane. Efficient adduct formation as a result of electrophilic attack by the phosphonium ion on various nucleophilic reagents, including 1,1,3,3-tetramethyl urea, methanesulfonic acid methyl ester, dimethyl sulfoxide and methyl salicylate, was also observed using the RIT device. The product ions of these reactions were analyzed using CID and the characteristic fragmentation patterns of the ionic addition products were recorded using multiple-stage experiments in the miniature RIT instrument. This study clearly demonstrates that a small, home-built, miniature RIT mass spectrometer can be used to perform analytically useful ion/molecule reactions and also that instruments like this have the potential to provide a portable platform for in situ detection of organophosphorus esters and related compounds with high specificity using tandem mass spectrometry. 相似文献
16.
Miniature gas chromatography (GC) and miniature mass spectrometry (MS) instrumentation has been developed to identify and quantify the chemical compounds present in complex mixtures of gases. The design approach utilizes micro-GC components coupled with a Paul quadrupole ion trap (QIT) mass spectrometer. Inherent to the system are high sensitivity, good dynamic range, good QIT resolution, low GC flow-rates to minimize vacuum requirements and the need for consumables; and the use of a modular approach to adapt to volatile organic compounds dissolved in water or present in sediment. Measurements are reported on system response to gaseous species at concentrations varying over four orders of magnitude. The ability of the system to deal with complicated mixtures is demonstrated, and future improvements are discussed. The GC/QIT system described herein has a mass, volume and power that are, conservatively, one-twentieth of those of commercial off-the-shelf systems. Potential applications are to spacecraft cabin-air monitoring, robotic planetary exploration and trace-species detection for residual gas analysis and environmental monitoring. 相似文献
17.
New approaches to miniaturizing ion trap mass analyzers 总被引:1,自引:0,他引:1
Ying PengDaniel E. Austin 《Trends in analytical chemistry : TRAC》2011,30(10):1560-1567
Development of miniaturized ion trap (IT) mass analyzers for portable mass spectrometry has taken advantage of the latest technology in conventional machining and microfabrication. Researchers are now turning to new materials, such as polymers and ceramics, as well as alternative electrode shapes and arrangements to create the precisely-shaped electric fields needed for good performance on small-scale devices. Polymer-based construction allows lightweight structures, complex shapes and inexpensive production of small ITs. Simplified electrode arrangements, such as ITs made from two patterned ceramic plates, allow precise electric fields and simplified electrode alignment. 相似文献
18.
Qinhua Chen Guangmin Pan Lin Xiong Hongsheng He Hangdong Yang 《Biomedical chromatography : BMC》2013,27(12):1615-1620
A rapid and sensitive method for the identification and quantification of 10‐hydroxycamptothecine (HCPT) in Camptotheca acuminata Decne is described. The HCPT standard solution was directly infused into the ion trap mass spectrometers (IT/MS) for collecting the MSn spectra. The electrospray ionization (ESI) mass spectral fragmentation pathway of HCPT was proposed and the ESI‐MSn fragmentation behavior of HCPT was deduced in detail. The major fragment ions of HCPT were confirmed by MSn in both negative ion and positive ion mode. The possible main cleavage pathway of fragment ions was studied. Quantification of HCPT was assigned in negative‐ion mode at a product ion at m/z 363 → 319 by LC‐MS. The LC‐MS method was validated for linearity, sensitivity, accuracy and precision, and then used to determine the content of the HCPT. Lastly, the LC‐MS method was successfully applied to determine HCPT in real samples of Camptotheca acuminate Decne and its medicinal preparation in the first time. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
19.
The application of a new hybrid RF/DC quadrupole-linear ion trap mass spectrometer to support drug metabolism and pharmacokinetic studies is described. The instrument is based on a quadrupole ion path and is capable of conventional tandem mass spectrometry (MS/MS) as well as several high-sensitivity ion trap MS scans using the final quadrupole as a linear ion trap. Several pharmaceutical compounds, including trocade, remikiren and tolcapone, were used to evaluate the capabilities of the system with positive and negative turbo ionspray, using either information-dependent data acquisition (IDA) or targeted analysis for the screening, identification and quantification of metabolites. Owing to the MS/MS in-space configuration, quadrupole-like CID spectra with ion trap sensitivity can be obtained without the classical low mass cutoff of 3D ion traps. The system also has MS(3) capability which allows fragmentation cascades to be followed. The combination of constant neutral loss or precursor ion scan with the enhanced product ion scan was found to be very selective for identifying metabolites at the picogram level in very complex matrices. Owing to the very high cycle time and, depending on the mass range, up to eight different MS experiments could be performed simultaneously without compromising chromatographic performance. Targeted product ion analysis was found to be complementary to IDA, in particular for very low concentrations. Comparable sensitivity was found in enhanced product ion scan and selected reaction monitoring modes. The instrument is particularly suitable for both qualitative and quantitative analysis. 相似文献
20.
Ten different samples with 13 previously identified saponin structures from Quillaja saponaria Molina were investigated by electrospray ionization ion trap multiple-stage mass spectrometry (ESI-ITMS(n)) in positive and negative ion modes. Both positive and negative ion mode MS(1)-MS(4) spectra were analyzed, showing that structural information on the two oligosaccharide parts in the saponin can be obtained from positive ion mode spectra whereas negative ion mode spectra mainly gave information on one of the oligosaccharide parts. Analysis of MS(1)-MS(4) spectra identified useful key fragment ions important for the structural elucidation of Quillaja saponins. A flowchart involving a stepwise procedure based on key fragments from MS(1)-MS(3) spectra was constructed for the identification of structural elements in the saponin. Peak intensity ratios in MS(3) spectra were found to be correlated with structural features of the investigated saponins and are therefore of value for the identification of terminal monosaccharide residues. 相似文献