首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for simultaneous quantification of docetaxel and ketoconazole in rat plasma with paclitaxel as internal standard (IS). The analytes were extracted from rat plasma by using a liquid-liquid extraction technique with ethyl acetate and the LC separation was performed on a Cosmosil-C(18) analytical column (150 mm x 2.0 mm i.d., Nacalai Tesque Inc., Japan). The extracted samples were analyzed with LC/MS/MS, operating in selected reaction monitoring (SRM) mode. The SRM transitions of precursor ions to product ions were 830.3-->549.1 (m/z) for docetaxel, 531.2-->489.3 (m/z) for ketoconazole, and 876.7-->307.9 (m/z) for the IS. The calibration curves were linear over the range of 2-500 ng/mL for docetaxel and 50-20 000 ng/mL for ketoconazole, with coefficients of correlation above 0.999. The limits of quantification for docetaxel and ketoconazole were both 2 ng/mL. The limit of detection for each analyte was 1 ng/mL. The intra- and inter-day precision (CV) of analysis were within 7%, and the accuracy ranged from 95 to 110%. The overall recoveries for docetaxel and ketoconazole were about 89.0% and 91.1%, respectively. The total analysis time was only 9.0 min. This quantitation method was successfully applied to the simultaneous determination of docetaxel and ketoconazole in rat plasma and some potential interaction was found in the current coadministration pharmacokinetic study. This established method was also utilized in the in vitro and in vivo drug-drug interaction study of docetaxel and ketoconazole (to be published).  相似文献   

2.
A rapid, simple and sensitive method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) with an electrospray ionization (ESI) source for the simultaneous analysis of fourteen water-soluble vitamins (B1, B2, two B3 vitamers, B5, five B6 vitamers, B8, B9, B12 and C) in various food matrices, i.e. maize flour, green and golden kiwi and tomato pulp, is presented here. Analytes were separated by ion-suppression reversed-phase liquid chromatography in less than 10 min and detected in positive ion mode. Sensitivity and specificity of this method allowed two important results to be achieved: (i) limits of detection of the analytes at ng g(-1) levels (except for vitamin C); (ii) development of a rapid sample treatment that minimizes analyte exposition to light, air and heat, eliminating any step of extract concentration. Analyte recovery depended on the type of matrix. In particular, recovery of the analytes in maize flour was > or =70%, with the exception of vitamin C, pyridoxal-5'-phosphate and vitamin B9 (ca 40%); with tomato pulp, recovery was > or =64%, except for vitamin C (41%); with kiwi, recovery was > or =73%, except for nicotinamide (ca. 30%).  相似文献   

3.
Toyo'oka T  Yano M  Kato M  Nakahara Y 《The Analyst》2001,126(8):1339-1345
The simultaneous determination of morphine and the glucuronide metabolites [morphine-3-beta-D-glucuronide (M3G) and morphine-6-beta-D-glucuronide (M6G)] in rat hair and rat plasma was carried out using reversed-phase high-performance liquid chromatography (HPLC) coupled with electrospray ionization mass spectrometry (ESI-MS). The chromatographic separation of the analytes was achieved using a semi-micro-HPLC column (3 microm particle size; 100 x 2.0 mm id) by gradient elution with 50 mM ammonium acetate and acetonitrile as eluents. After separation, morphine and the glucuronides were determined by selected ion monitoring (SIM) of ESI-MS using the quasi-molecular ions [M + H]+ at m/z = 286 and 462, respectively. The calibration curves were linear between the concentration of the analytes and the deuterium-labelled morphine (M-d3) selected as internal standard. The method was applied for the determination of the incorporation of morphine and the glucuronides into the hair shafts and hair roots of Dark Agouti rats after single intraperitoneal administration of morphine hydrochloride. Plasma concentrations of morphine and glucuronides were simultaneously determined after administration. Morphine and M3G were detected in the hair shafts and the hair roots. The concentrations of M3G in the hair root were lower than those of morphine in all sampling periods. In contrast, M3G concentrations in plasma were relatively higher at each sampling time. Small quantities of M6G were also identified in the plasma up to 4 h after administration. The concentration difference between the hair root and plasma seems to be due to the incorporation ratio of morphine and glucuronide into hair. As M3G was also identified in the hair shaft 1 week after administration, the incorporation of glucuronide metabolites into hair is obvious. This is the first report of the identification of morphine glucuronide in hair samples without the use of acid hydrolysis or enzyme digestion.  相似文献   

4.
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds.  相似文献   

5.
6.
A simple and highly sensitive liquid chromatographic/electrospray tandem mass spectrometric (LC/MS/MS) assay was developed for the simultaneous determination of risperidone (RSP) and its major circulating metabolite 9-hydroxyrisperidone (9-OH-RSP) in the plasma of humans and rats. A simple one-step solvent extraction with 15% methylene chloride in pentane was used to isolate the compounds from plasma. The compounds were eluted from a phenyl-hexyl column and detected with a Perkin-Elmer SCIEX API2000 triple-quadrupole mass spectrometer using positive ion atmospheric pressure electrospray ionization and multiple reaction monitoring. The assay was linear over the range 0.1-100 ng ml(-1) when 0.5 ml of plasma was used in the extraction. The overall intra- (within-day) and inter- (between days) assay variations were < 11%. The variations in the concentrations of two long-term quality control samples from pooled patient plasma samples analyzed over a period of 6 months were approximately 10%. The analysis time for each sample was 4 min and more than 100 samples could be analyzed in one day by running the system overnight. The assay is simple, highly sensitive, selective, precise and fast. This method is being used for the therapeutic drug monitoring of schizophrenic patients treated with RSP and to study the pharmacokinetics and tissue distribution of RSP and 9-OH-RSP in rats.  相似文献   

7.
Glutathione (GSH) is a tripeptide composed of glutamate, cysteine, and glycine. It is present in practically all cells and has several important roles, such as preventing the oxidation of the sulfhydryl groups of proteins within a cell. Evidence for GSH deficiency or depletion has been found in a variety of diseases and toxicity-related studies, including diabetes and induction of oxidative stress to form reactive oxygen species which cause DNA, lipid, and protein oxidations. A simple, selective, and sensitive analytical method for measuring low levels of GSH in biological fluids would therefore be desirable to conduct GSH deficiency or depletion-related mechanistic toxicity studies. Here a method for both low- and high-level quantitation of GSH from cultured cells and rat liver tissues via liquid chromatography/positive electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) has been developed. The lower limit of quantitation (LOQ) of the method was 5 ng/mL. The method is linear over a wide dynamic concentration range of 5.0 to 5000.0 ng/mL, with a correlation coefficient R2 > 0.99. The intra-day assay precision relative standard deviation (RSD) values for all quality control (QC) samples were < or =16.31%, with accuracy values ranging from 94.13 to 97.80%. The inter-day assay precision RSD values for all QC samples were < or =15.94%, with accuracy values ranging from 94.51 to 100.29%. With this method, low levels of GSH from diethyl maleate (DEM)-treated mouse lymphoma cells, and GSH in rat liver tissues, were quantified.  相似文献   

8.
A rapid and sensitive liquid chromatography hyphenated with electrospray ionization tandem mass spectrometric method (LC–ESI–MS/MS) was developed and validated for simultaneous determination of evobrutinib and evobrutinib‐diol in dog plasma. The plasma sample was processed using acetonitrile and chromatographic separation was carried out on a Waters Acquity BEH C18 column (50 × 2.1 mm, 1.7 μm). The mobile phase was composed of 0.1% formic acid and acetonitrile, with an optimized gradient elution at a flow rate of 0.4 mL/min. Detection was accomplished in selective reaction monitoring mode via electrospray ionization interface operated in positive ion mode. The precursor‐to‐product transitions for quantification were m/z 430.2 → 98.1 for evobrutinib, m/z 464.2 → 98.1 for evobrutinib‐diol and m/z 441.2 → 138.1 for ibrutinib (internal standard). The developed assay was linear over the tested concentration ranges with correlation coefficient >0.995. The LLOQ was 0.1 ng/mL for both analytes. The inter‐ and intra‐day precisions were <9.65% and the accuracy ranged from ?3.94 to 6.37%. The extraction recovery was >85.41% and no significant matrix effect was observed. The developed assay was successfully applied to the pharmacokinetic study of evobrutinib and evobrutinib‐diol in dogs after oral administration of evobrutinib at a single dose of 5 mg/kg.  相似文献   

9.
A method for the determination of several household biocides in water by liquid chromatography/electrospray ionisation tandem mass spectrometry (LC/ESI‐MS/MS) is presented. It permits the simultaneous determination of triclosan (TCS), triclocarban (TCC) and seven parabens, including the distinction between branched and linear isomers of propyl (i‐PrP and n‐PrP) and butyl parabens (i‐BuP and n‐BuP). Prior to LC/MS/MS, analytes are preconcentrated by solid‐phase extraction (SPE) on Oasis HLB (60 mg) cartridges at natural sample pH and subsequently eluted with 4 mL of methanol. This simple SPE procedure provides extraction recoveries above 85% except for raw wastewater, where it falls to 65% for TCC. The performance of the method was tested with two triple‐quadrupole LC/MS instruments from a low/mid and mid/high market range: a Varian 1200L and an API‐4000. The latter system provided between 3 and 80 times lower limits of quantification (LOQs) than the first one, in the 0.08–0.44 ng/L range for surface water. Moreover, a comparison of matrix effects on both instruments showed a very different behaviour, particularly in the case of parabens. For these compounds signal suppression was observed in the 1200L instrument and signal enhancement with the 4000 instrument. As a result, different calibration approaches were chosen for them and this pointed to the need of matrix effect re‐evaluation in method transfer between different LC/MS systems. The application of the method to real samples showed the ubiquity of methyl paraben (MeP) and n‐PrP (at the 1–6 µg/L in raw wastewater) and the coexistence of i‐BuP and n‐BuP at similar levels (ca. 100–200 ng/L in raw wastewater). Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
The aim of this study was to develop and validate a novel solid-phase extraction (SPE) liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the simultaneous determination of two antineoplastic drugs, cyclophosphamide (CP) and methotrexate (MTX), in human urine using trophosphamide as internal standard. The method showed good precision and accuracy (mean RSD 2.8% and 0.9%; bias 2.7% and 2.4% for MTX and CP, respectively). The lower limits of detection obtained, 0.2 microg/L(urine) for MTX and 0.04 microg/L(urine) for CP, were lower than the best previously reported values. The use of a 96-well SPE plate for matrix purification ensures a high throughput (50 samples/day), allowing the routine biological monitoring of CP and MTX as measures of occupational exposure at very low levels.  相似文献   

11.
The behaviour of 5-methyl-2'-deoxycytidine (m(5)dCyd, claimed to be a potential marker for leukaemia) during the electrospray process was studied. In particular, considerations concerning the effect of solution chemistry (e.g. analyte concentration, pH, etc.) on electrospray ionization mass spectra were drawn. Furthermore, a procedure using liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) for the determination of urinary m(5)dCyd is described. The method is simple, sensitive and highly specific. The pre-treatment procedure gave an average recovery of 79% (relative standard deviation (RSD) of 3%). Method performance was evaluated on spiked urine samples covering the concentration range from 50 ng/mL to 10 microgram/mL, the same as that of an existing inhibition ELISA method. Contrary to findings based on this immunoassay technique, urinary m(5)dCyd in healthy individuals was not detectable and did not increase in the presence of the malignant disease.  相似文献   

12.
A simple and sensitive liquid chromatography/tandem mass spectrometry method was developed and validated for determining rosuvastatin in human plasma, a new synthetic hydroxymethylglutaryl-coenzyme A reductase inhibitor. The analyte and internal standard (IS; cilostazol) were extracted by simple one-step liquid/liquid extraction with ether. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The chromatographic separation was performed on an Atlantis C18 column (2.1 mm x 150 mm, 5.0 microm) with a mobile phase consisting of 0.2% formic acid/methanol (30:70, v/v) at a flow rate of 0.20 mL/min. The analyses were carried out by multiple reaction monitoring (MRM) using the precursor-to-product combinations of m/z 482 --> 258 and m/z 370 --> 288. The areas of peaks from the analyte and the IS were used for quantification of rosuvastatin. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification (LLOQ) was 0.2 ng/mL and the assay exhibited a linear range of 0.2-50.0 ng/mL and gave a correlation coefficient (r) of 0.9991 or better. Quality control samples (0.4, 8, 25 and 40 ng/mL) in six replicates from three different runs of analysis demonstrated an intra-assay precision (RSD) 7.97-15.94%, an inter-assay precision 3.19-15.27%, and an overall accuracy (relative error) of < 3.7%. The method can be applied to pharmacokinetic or bioequivalence studies of rosuvastatin.  相似文献   

13.
Electrospray ionization multi-stage tandem mass spectrometry (ESI-MS(n)) and liquid chromatography coupled with on-line mass spectrometry (LC/MS/MS) were applied to characterize saponins in crude extracts from Panax ginseng. The MS(n) data of the [M - H](-) ions of saponins can provide structural information on the sugar sequences of the saccharide chains and on the sapogins of saponins. By ESI-MS(n), non-isomeric saponins and isomeric saponins with different aglycones can be determined rapidly in plant extracts. LC/MS/MS is a good complementary analytical tool for determination of isomeric saponins. These approaches constitute powerful analytical tools for rapid screening and structural assignment of saponins in plant extracts.  相似文献   

14.
A simple and sensitive method is described for the determination of E5880 in rat plasma. The method is based on high-performance liquid chromatography/electrospray ionization mass spectrometry, using deuterated E5880 as an internal standard. Selected reaction monitoring is employed for selectivity and sensitivity, this in turn enables quantification in a short period of time (within 7 minutes) over the extended range of 0.1-1000 ng/ml with acceptable precision and accuracy. The method demonstrated to be suitable for the quantitative analysis of E5880 in rat plasma. The pharmacokinetic profile of E5880 after a single intravenous administration of E5880 was elucidated.  相似文献   

15.
何强  李建华  孔祥虹  乐爱山  吴双民 《色谱》2010,28(12):1128-1131
建立了浓缩苹果汁中链格孢霉素、链格孢酚、腾毒素、链格孢酚甲醚4种毒素残留量的固相萃取-超高效液相色谱-串联质谱检测方法。样品用水稀释后,用PS DVB固相萃取柱净化,外标法定量。测定时用BEH C18色谱柱(50 mm×2.1 mm, 1.7 μm)分离,乙腈和水梯度洗脱,质谱测定采用多反应监测(MRM)模式。4种链格孢霉毒素的测定低限在1.0~5.0 μg/L范围内,加标回收率为77.8%~117.2%,相对标准偏差均低于9.7%。该方法灵敏、稳定、可靠,可用于浓缩苹果汁样品中4种链格孢霉毒素的检测和确证。  相似文献   

16.
Tanreqing capsule (TRQC) is a formulation frequently used in traditional Chinese medicine to treat pyrexia, cough, expectoration and pharyngalgia. Since the pharmacological action of traditional Chinese medicines is closely related to their complex and diverse constituents, understanding the exact composition of TRQC is important to elucidate its clinical effectiveness and mechanism of action as well as to establish quality control methods and resolve safety issues. Herein, we employed high‐performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry for the simultaneous quantitation of 23 bioactive compounds in five batches of TRQC; the analytes could be categorized into five types: organic acids (seven compounds), flavonoids (10 compounds), iridoids (two compounds), phenylethanoid glycosides (two compounds) and bile acids (two compounds). The calibration curves for all analytes showed good linearity (r > 0.9953), and the inter‐ and intra‐day precisions did not exceed 4.94 and 4.97%, respectively. The recoveries varied from 90.47% to 109.80%; the corresponding relative standard deviations (RSDs) did not exceed 4.94%; and the repeatability (RSD < 4.72%) and stability (RSD < 4.88%) were also within acceptable limits. Thus, this study can be viewed as a fundamental reference for setting comprehensive TRQC quality standards.  相似文献   

17.
Phytohormones have attracted wide attention due to their important biological functions. However, their detection is still a challenge because of their complex composition, low abundance and diverse sources. In this study, a novel method of high‐performance liquid chromatography with electrospray ionization tandem mass spectrometry was developed and validated for the simultaneous determination of ten phytohormones including indole‐3‐acetic acid, isopentenyladenine, isopentenyl adenosine, trans‐zeatin riboside, zeatin, strigolactones, abscisic acid, salicylic acid, gibberellin A3, and jasmonic acid in Sargassum horneri (S. horneri). The phytohormones were extracted from freeze‐dried S. horneri with methanol/water/methanoic acid (15:4:1, v/v/v) analyzed on a Hypersil Gold C18 column and detected by electrospray ionization tandem triple quadrupole mass spectrometry in the multiple reaction monitoring mode. The experimental conditions for the extraction and analysis of phytohormones were optimized and validated in terms of reproducibility, linearity, sensitivity, recovery, accuracy, and stability. Distributions of the phytohormones in the stems, blades, and gas bladder of the S. horneri in drift, fixed, and semi‐fixed growing states were investigated for the first time. The observed contents of the phytohormones in S. horneri range from not detected to 5066.67 ng/g (fresh weight). Most phytohormones are distributed mainly in the stems of S. horneri in drift and semi‐fixed states.  相似文献   

18.
Mass spectrometry of ochratoxin A (OTA) and B (OTB) under electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) was studied. ESI offers higher sensitivities and less fragmentation than APCI. A sensitive LC/MS/MS method for the determination of ochratoxin A (OTA) in human plasma samples was developed. The absolute minimum detection limit was around 10-20 pg per injection, corresponding to 0.5 ppb in an injection equivalent to 20-40microg of human plasma. Ochratoxin B (OTB) was used as an internal standard and its absence in real-life samples was carefully checked before samples were spiked with the internal standard. It was found that these two ochratoxins are susceptible to sodium adduct formation. Fragment ions from the [M + H](+) and [M + Na](+) ions of both OTA and OTB were monitored in the multiple reaction monitoring mode. Three quantitative approaches, standard addition method, internal standard method (using ochratoxin B as an internal standard) and external standard method, were compared in the analysis of human blood plasma. Results from the mass spectrometric method were comparable to those from a conventional LC/fluorescence method. The LC/MS/MS method was also applied to the analysis of contaminated coffee samples.  相似文献   

19.
A method for the determination of ethyl glucuronide (EtG) in hair samples, using liquid chromatography/electrospray tandem mass spectrometry (LC/ESI-MS/MS), was developed and validated. The treatment of hair samples was as follows: to 100 mg of washed (dichloromethane followed by methanol, 1 ml each) and cut (1-2 mm) material, 700 microl of water, 20 microl of internal standard solution (pentadeuterated EtG, D(5)-EtG, 500 microg/l) and 20 microl of methanol were added. Samples were incubated at 25 degrees C overnight and then ultrasonicated for 2 h. Finally, 8 microl of the centrifuged solution (13,000 rpm) were analyzed by LC/ESI-MS/MS in negative ion mode. The surviving ions of EtG and D(5)-EtG were monitored together with the following MRM transitions: m/z 221 --> 75, m/z 221 --> 85 (EtG) and m/z 226 --> 75, m/z 226 --> 85 (D(5)-EtG). The method exhibited a mean correlation coefficient better than 0.9998 over the dynamic range (3-2000 pg/mg). The lower limit of quantification (LLOQ) and the limit of detection (LOD) were 3 and 2 pg/mg respectively. The intra- and interday precision and accuracy were studied at four different concentration levels (3, 5, 56 and 160 pg/mg) and were always better than 7% (n = 5). Matrix effects did not exceed 20%. The method was applied to several hair samples taken from autopsies of known alcoholics, from patients in withdrawal treatment, from social drinkers, from adult teetotalers and from children not exposed to ethanol, with EtG concentrations globally ranging from < or =2 to 4180 pg/mg.  相似文献   

20.
Analytical techniques for the detection of small amounts of explosives (in the picogram range) are now involved in various application. Some of them concern soil, water and air monitoring in order to face environmental problems related to improper handling procedures either in stocking or in wasting of the explosive products. Other areas are strictly related to forensic analysis of samples coming either from explosion areas where the matrix is various (metal, glass, wood, scraps), or from explosives transportation related to international terrorism. Generally speaking, for these applications the bulk of the matrix seriously interferes in the detection of the explosive analyte, which is usually present at trace levels. Unfortunately, despite some improvements, analytical techniques developed up today in this domain are still faced to two main constraints: the introduction of new products with unanticipated chemico-physical properties and the requirement of a routine and fast analytical method which can handle any matrix with a minimal clean-up and performing a sensitivity compatible either with the ever-decreasing demanded detection limit and with the ever-decreasing available specimen amount. These requirements can be fulfilled now by the new LC-MS and LC-MSMS techniques: mass spectrometry (MS) is likely an universal detector but even specific, especially when implemented in tandem MS (MSMS); LC is by far the most suitable technique to handle such a kind of compounds. Moreover, of a particular concern are some explosives which are reported to be thermally stable but difficult to dissolve. Some of the experiments on characterization of explosives [Octagen (HMX), Ethyleneglycol dinitrate (EGDN), Exogen (RDX), Propanetriol trinitrate (NG), Trinitrotoluene (TNT), N-Methyl-N-tetranitrobenzenamine (TETRYL), Dintrotoluene (DNT), Bis-(nitrooxy-methyl) propanediol dinitrate (PETN), Hexanitrostilbene (HNS), Triazido-trinitrobenzene (TNTAB), Tetranitro-acridone (TENAC), Hexa-nitrodiphenylamine (HEXYL), Nitroguanidine (NQ)] by LC-MS and LC-MSMS with the API-IonSpray source and using the Parent-Scan technique are presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号