首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
This article presents the specificities of low pressure chemical ionization in ion trap mass spectrometry. One main feature is the ability to perform chemical ionization with liquid reagents as readily as with "conventional" gases (methane, isobutane and ammonia). The reactivities and analytical applications of gas and liquid reagents are summarized from literature data and are compared when possible.  相似文献   

2.
Super‐atmospheric pressure chemical ionization (APCI) mass spectrometry was performed using a commercial mass spectrometer by pressurizing the ion source with compressed air up to 7 atm. Similar to typical APCI source, reactant ions in the experiment were generated with corona discharge using a needle electrode. Although a higher needle potential was necessary to initiate the corona discharge, discharge current and detected ion signal were stable at all tested pressures. A Roots booster pump with variable pumping speed was installed between the evacuation port of the mass spectrometer and the original rough pumps to maintain a same pressure in the first pumping stage of the mass spectrometer regardless of ion source pressure. Measurement of gaseous methamphetamine and research department explosive showed an increase in ion intensity with the ion source pressure until an optimum pressure at around 4–5 atm. Beyond 5 atm, the ion intensity decreased with further increase of pressure, likely due to greater ion losses inside the ion transport capillary. For benzene, it was found that besides molecular ion and protonated species, ion due to [M + 2H]+ which was not so common in APCI, was also observed with high ion abundance under super‐atmospheric pressure condition. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
4.
A novel approach, based on the use of atmospheric pressure chemical ionization ion trap mass spectrometry (APCI-ITMS) conditions, but without using corona discharge, was used to analyze peptides. The proposed method was applied to three standard peptides (bombesin, trityrosine and tyrosine-glycine-glycine) as well as peptides obtained through enzymatic digestion of two standard proteins (horse cytochrome c and horse myoglobin).  相似文献   

5.
6.
Atmospheric pressure chemical ionization (APCI)-mass spectrometry (MS) for fluorinated phenols (C6H5-xFxOH Where x = 0-5) in nitrogen with Cl- as the reagent ion yielded product ions of M Cl- through ion associations or (M-H)- through proton abstractions. Proton abstraction was controllable by potentials on the orifice and first lens, suggesting that some proton abstraction occurs through collision induced dissociation (CID) in the interface region. This was proven using CID of adduct ions (M Cl-) with Q2 studies where adduct ions were dissociated to Cl- or proton abstracted to (M-H)-. The extent of proton abstraction depended upon ion energy and structure in order of calculated acidities: pentafluorophenol > tetrafluorophenol > trifluorophenol > difluorophenol. Little or no proton abstraction occurred for fluorophenol, phenol, or benzyl alcohol analogs. Ion mobility spectrometry was used to determine if proton abstraction reactions passed through an adduct intermediate with thermalized ions and mobility spectra for all chemicals were obtained from 25 to 200 degrees C. Proton abstraction from M Cl- was not observed at any temperature for phenol, monofluorophenol, or difluorophenol. Mobility spectra for trifluorophenol revealed the kinetic transformations to (M-H)- either from M Cl- or from M2 Cl- directly. Proton abstraction was the predominant reaction for tetra- and penta-fluorophenols. Consequently, the evidence suggests that proton abstraction occurs from an adduct ion where the reaction barrier is reduced with increasing acidity of the O-H bond in C6H5-xFxOH.  相似文献   

7.
The mass spectral signatures of airborne bacteria were measured and analyzed in cloud simulation experiments at the AIDA (Aerosol Interaction and Dynamics in the Atmosphere) facility. Suspensions of cultured cells in pure water were sprayed into the aerosol and cloud chambers forming an aerosol which consisted of intact cells, cell fragments and residual particles from the agar medium in which the bacteria were cultured. The aerosol particles were analyzed with a high‐resolution time‐of‐flight aerosol mass spectrometer equipped with a newly developed PM2.5 aerodynamic lens. Positive matrix factorization (PMF) using the multilinear engine (ME‐2) source apportionment was applied to deconvolve the bacteria and agar mass spectral signatures. The bacteria mass fraction contributed between 75 and 95% depending on the aerosol generation, with the remaining mass attributed to agar. We present mass spectra of Pseudomonas syringae and Pseudomonas fluorescens bacteria typical for ice‐nucleation active bacteria in the atmosphere to facilitate the distinction of airborne bacteria from other constituents in ambient aerosol, e.g. by PMF/ME‐2 source apportionment analyses. Nitrogen‐containing ions were the most salient feature of the bacteria mass spectra, and a combination of C4H8N+ (m/z 70) and C5H12N+ (m/z 86) may be used as marker ions. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
The nerve agent VX (O-ethyl S-2-diisopropylaminoethyl methyl phosphonothiolate) was analyzed on the surface of concrete samples using an ion trap secondary ion mass spectrometer (IT-SIMS). It was found that VX could be detected down to an absolute quantity of 5 ng on a concrete chip, or to a surface coverage of 0.0004 monolayers on crushed concrete. To achieve these levels of detection, the m/z 268-->128 ion fragmentation was measured using MS2, where m/z 268 corresponds to [VX + H]+, and 128 corresponds to a diisopropylvinylammonium isomer, that is formed by the elimination of the phosphonothiolate moiety. Detection at these levels was accomplished by analyzing samples that had been recently exposed to VX, i.e., within an hour. When the VX-exposed concrete samples were aged, the SIMS signature for intact VX had disappeared, which signaled the degradation of the compound on the concrete surface. The VX signature was replaced by ions which are interpreted in terms of VX degradation products, which appear to be somewhat long lived on the concrete surface. These compounds include ethylmethylphosphonic acid (EMPA), diisopropyl taurine (DIPT), diisopropylaminoethanethiol (DESH), bis(diisopropylaminoethane) disulfide [(DES)2], and a particularly tenacious compound that may correspond to diisopropylvinylamine (DIVA), or an isomer thereof. It was found that the thiolamine-derived degradation products DIPT, DESH, and (DES)2 were removed with isopropyl alcohol extraction. However, the DIVA-related degradation product was observed to strongly adhere to the concrete surface for longer than one week. Although quantitation was not possible in this set of experiments, the results clearly show the rapid degradation of VX on concrete, as well as the surface sensitivity of the IT-SIMS for intact VX and its adsorptive degradation products.  相似文献   

9.
用液相色谱/大气压化学电离离子阱质谱建立了一种分析烟草中游离茄尼醇的方法。烟草样品用甲醇振荡提取30 min,在分析前无需进行其它前处理。在1.8μm快速分离C18色谱短柱上用V(甲醇)∶V(异丙醇)=85∶15等梯度洗脱实现了茄尼醇的快速分离。用不带碰撞能量的二级质谱全扫描选择监测离子m/z 613.6进行定量,检出限为0.4μg/L,RSD为1.1%,两种添加量的回收率分别为97%和99%。方法应用于不同烟草和烟草制品样品的检测分析。  相似文献   

10.
A modified atmospheric pressure chemical ionization ion source is applied for direct analysis of volatile or low volatile organic compounds in air. The method is based on the direct introduction of the analytes in the gas phase and/or particle phase into the ion source of a commercial ion-trap mass spectrometer. Two methods are employed for the production of primary ions at atmospheric pressure, photoionization and corona discharge. It is shown that in the presence of a dopant, photoionization can be a highly efficient ionization method also for real-time analysis with detection limits for selected analytes in the lower ppt-range. Using corona discharge for the production of primary ions, which is instrumentally easier since no additional chemicals have to be added to the sample flow, we demonstrate the analytical potential of on-line atmospheric pressure chemical ionization mass spectrometry for reaction monitoring experiments. To do so, an atmospherically relevant gas phase reaction is carried out in a 500 l reaction chamber and gaseous and particulate compounds are monitored in the positive and negative ion mode of the mass spectrometer.  相似文献   

11.
Bacteriohopanepolyols (BHPs) fragment via characteristic pathways during atmospheric pressure chemical ionisation liquid chromatography/ion trap mass spectrometry (APCI-LC/MS(n)). Comparison of the MS(2) spectra of bacteriohopane-32,33,34,35-tetrol (BHT) and 2 beta-methylbacteriohopane-32,33,34,35-tetrol has confirmed the previously proposed ring-C cleavage occurring between C-9 and 11 and C-8 and 14. This fragmentation, diagnostic of all hopanoids, also occurs in BHPs containing an amino group (-NH(2)) at C-35 although the higher relative stability of the ion limits this fragmentation to a minor process after protonation of the basic nitrogen function. Studies of a number of cell cultures including a prochlorophyte (Prochlorothrix hollandica) and a cyanobacterium (Chlorogloeopsis LA) demonstrate the power of this technique to detect composite BHPs with a complex biological functionality at C-35. We also report the first observation of intact pentafunctionalised bacteriohopanepolyols using this method.  相似文献   

12.
Atmospheric pressure (AP) matrix‐assisted laser desorption/ionization (MALDI) is known to suffer from poor ion transfer efficiencies as compared to conventional vacuum MALDI (vMALDI). To mitigate these issues, a new AP‐MALDI ion source utilizing a coaxial gas flow was developed. Nitrogen, helium, and sulfur hexafluoride were tested for their abilities as ion carriers for a standard peptide and small drug molecules. Nitrogen showed the best ion transport efficiency, with sensitivity gains of up to 1900% and 20% for a peptide standard when the target plate voltage was either continuous or pulsed, respectively. The addition of carrier gas not only entrained the ions efficiently but also deflected background species and declustered analyte–matrix adducts, resulting in higher absolute analyte signal intensities and greater signal‐to‐noise (S/N) ratios. With the increased sensitivity of pneumatically assisted (PA) AP‐MALDI, the limits of detection of angiotensin I were 20 or 3 fmols for continuous or pulsed target plate voltage, respectively. For analyzing low‐mass analytes, it was found that very low gas flow rates (0.3–0.6 l min?1) were preferable owing to increased fragmentation at higher gas flows. The analyte lability, type of gas, and nature of the extraction field between the target plate and mass spectrometer inlet were observed to be the most important factors affecting the performance of the in‐line PA‐AP‐MALDI ion source. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
There is an increasing need to be able to conduct quantitative lipidomics analyses as a complement to proteomics studies. The highest specificity for proteomics analysis can be obtained using methodology based on electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) coupled with liquid chromatography/tandem mass spectrometry (LC/MS/MS). For lipidomics analysis it is often necessary to be able to separate enantiomers and regioisomers. This can be very challenging when using methodology based on conventional reversed-phase chromatography. Normal-phase chromatography using chiral columns can provide dramatic improvements in the resolution of enantiomers and regioisomers. However, conventional ESI- and APCI-MS/MS has limited sensitivity, which makes it difficult to conduct studies in cell culture systems where only trace amounts of non-esterified bioactive lipids are present. The use of electron capture APCI-MS/MS overcomes this problem. Enantiomers and regioisomers of diverse bioactive lipids can be quantified using stable isotope dilution methodology coupled with normal-phase chiral chromatography and electron capture APCI-MS/MS. This methodology has allowed a lipidomics profile from rat epithelial cells maintained in culture to be delineated and allowed the effect of a non-selective lipoxygenase inhibitor to be assessed.  相似文献   

14.
A real-time analysis of secondary organic aerosol (SOA) particles formed from cyclohexene ozonolysis in a smog chamber was performed using a laser-ionization single-particle aerosol mass spectrometer (LISPA-MS). The instrument obtains both size and chemical compositions of individual aerosol particles with a high time-resolution (approximately 2 s at the maximum). Both positive and negative-ion mass spectra are obtained. Standard particles generated from dicarboxylic acid solutions using an atomizer were also analyzed. For both standard and SOA particles, the negative-ion mass spectra provided information about the molecular weights of the organic compounds in the particles, since the intense ions in the negative-ion mass spectra are mainly attributable to the molecular-related ions [M-H]-. It was demonstrated that the real-time single-particle analysis of SOA particles by the LISPA-MS technique can reveal the formation and transformation processes of SOA particle in smog chambers.  相似文献   

15.
The direct determination of dialkyl phosphates (DAPs) in water by strong anion-exchange (SAX) liquid chromatography/atmospheric pressure chemical ionization (APCI) mass spectrometry was investigated. The SAX high-performance liquid chromatography (HPLC) column was eluted with methanol/water gradients containing ammonium formate (AF) separating the DAPs which included six dimethyl- and diethyl-substituted phosphates, thiophosphates, and dithiophosphates. The high buffer concentrations required for separation were compatible with -ve APCI, but in +ve APCI the DAPs were unstable giving anomalous ions such as [M+15]+ and [M+29]+. These ions are believed to result from ion molecule reactions with CH3OH2+ in the plasma. DAPs are very stable in -ve APCI being detected as abundant [M-H](-) ions, even with 200 mM AF. At higher AF concentration formate clusters ([M+45](-) and [M+91](-)) were seen. Fragmentation by collision-activated dissociation (CAD) was more efficient for deprotonated ethyl-substituted DAPs which lost ethylene followed by ethanol. APCI instrument detection limits were in the low ng/mL range and the response was highly linear. Isotope dilution quantitation using d10-diethyl dithiophosphate (DEDTP) as an internal standard produced an instrument detection limit of 2 ng DEDTP/mL and method detection limit (MDL) of 9.3 ng/mL with accuracy of 99% (spike concentration, 25 ng/mL). DAP mixtures required storage in cold, dry conditions and alcohol solvents should be avoided because of solvolysis reactions.  相似文献   

16.
The ionization pathways were determined for sets of isomeric non-polar hydrocarbons (structural isomers, cis/trans isomers) using ion mobility spectrometry and mass spectrometry with different techniques of atmospheric pressure chemical ionization to assess the influence of structural features on ion formation. Depending on the structural features, different ions were observed using mass spectrometry. Unsaturated hydrocarbons formed mostly [M - 1]+ and [(M - 1)2H]+ ions while mainly [M - 3]+ and [(M - 3)H2O]+ ions were found for saturated cis/trans isomers using photoionization and 63Ni ionization. These ionization methods and corona discharge ionization were used for ion mobility measurements of these compounds. Different ions were detected for compounds with different structural features. 63Ni ionization and photoionization provide comparable ions for every set of isomers. The product ions formed can be clearly attributed to the structures identified. However, differences in relative abundance of product ions were found. Although corona discharge ionization permits the most sensitive detection of non-polar hydrocarbons, the spectra detected are complex and differ from those obtained with 63Ni ionization and photoionization.  相似文献   

17.
We present the results of studying the effects of temperature and humidity of the reaction medium and the intensity of ultraviolet radiation on the atmospheric pressure chemical ionization of Penthrite. The peculiarities of the ion mobility spectra of this compound obtained by ion mobility spectrometry-tandem mass spectrometry are analyzed.  相似文献   

18.
Triclosan is a widely used broad‐spectrum antibacterial agent that acts by specifically inhibiting enoyl–acyl carrier protein reductase. An in vitro metabolic study of triclosan was performed by using Sprague‐Dawley (SD) rat liver S9 and microsome, while the in vivo metabolism was investigated on SD rats. Twelve metabolites were identified by using in‐source fragmentation from high‐performance liquid chromatography/negative atmospheric pressure chemical ionization ion trap mass spectrometry (HPLC/APCI‐ITMS) analysis. Compared to electrospray ionization mass spectrometry (ESI‐MS) and tandem mass spectrometry (MS/MS) that gave little fragmentation for triclosan and its metabolites, the in‐source fragmentation under APCI provided intensive fragmentations for the structural identifications. The in vitro metabolic rate of triclosan was quantitatively determined by using HPLC/ESI‐ITMS with the monitoring of the selected triclosan molecular ion. The metabolism results indicated that glucuronidation and sulfonation were the major pathways of phase II metabolism and the hydroxylated products were the major phase I metabolites. Moreover, glucose, mercapturic acid and cysteine conjugates of triclosan were also observed in the urine samples of rats orally administrated with triclosan. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
A new continuous chromatographic process (VARICOL) has been presented recently. The basic principle of the new VARICOL process consists of an asynchronous shift of the inlet/outlet lines in a multi-column system on a recycle loop. This process has been used to perform the separation of the optical isomers of the SB-553261 racemate. In this paper, we illustrate that for this specific separation, the VARICOL process is more efficient than the well-known SMB process.  相似文献   

20.
beta-Sitosterol and stigmasterol are the most common phytosterols in traditional Chinese medicine. They have been proved to have many important bioactivities. To the best of our knowledge, this is the first report that beta-sitosterol, stigmasterol and ergosterol coexisting in A. roxburghii herbs can be simultaneously extracted by a supercritical fluid extraction (SFE) procedure; then a simple high-performance liquid chromatography/atmospheric pressure chemical ionization ion trap mass spectrometry (HPLC/APCI/MS) method was developed for simultaneous identification and determination of these three compounds. The ion trap MS/MS detector was equipped with an atmospheric pressure chemical ionization source operating in the positive ion mode, APCI(+). The linear responses were obtained in the concentration range of 0.50-150 microg/mL (r = 0.9999) for ergosterol, 5-400 microg/mL (r = 0.9999) for stigmasterol, and 10-2000 microg/mL (r = 0.9998) for beta-sitosterol. An orthogonal L(9) (3(3)) test design was employed for optimization of the SFE process. Under the optimized conditions, i.e. pressure of 25 mPa, temperature of 45 degrees C and ethanol as modifier, the concentrations of sterols in the extract were found to be 2.89% (g/g) for beta-sitosterol, 3.56% (g/g) for stigmasterol and 2.96% (g/g) for ergosterin. The SFE method was also compared with a previously developed Soxhlet extraction. The SFE method produced higher yields of sterols than that of the Soxhlet extraction. The proposed method has been successfully used for identification and quantitation of beta-sitosterol, stigmasterol and ergosterin in a real A. roxburghii sample.  相似文献   