首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
《Electrophoresis》2017,38(7):1044-1052
Capillary electrophoresis is an important technique for the characterization of monoclonal antibodies (mAbs), especially in the pharmaceutical context. However, identification is difficult as upscaling and hyphenation of used methods directly to mass spectrometry is often not possible due to separation medium components that are incompatible with MS detection. Here a CE‐MS method for the analysis of mAbs is presented analyzing SDS‐complexed samples. To obtain narrow and intensive peaks of SDS‐treated antibodies, an in‐capillary strategy was developed based on the co‐injection of positively charged surfactants and methanol as organic solvent. For samples containing 0.2% (v/v) of SDS, recovered MS peak intensities up to 97 and 95% were achieved using cetyltrimethylammonium bromide or benzalkonium chloride, respectively. Successful removal of SDS was shown in neutral coated capillaries but also in a capillary with a positively charged coating applying reversed polarity. The usefulness of this in‐capillary strategy was demonstrated also for other proteins and for antibodies dissolved in up to 10% v/v SDS solution, and in other SDS‐containing matrices, including the sieving matrix used in a standard CE‐SDS method and gel‐buffers applied in SDS‐PAGE methods. The developed CE‐MS approaches enable fast and reproducible characterization of SDS‐complexed antibodies.  相似文献   

2.
In this work, a new physically adsorbed coating for capillary electrophoresis (CE) is presented. The coating is based on a N,N-dimethylacrylamide-ethylpyrrolidine methacrylate (DMA-EPyM) copolymer synthesized in our laboratory. The capillary coating is simple and easy to obtain as only requires flushing the capillary with a polymer aqueous solution for 2 min. It is shown that by using these coated capillaries the electrostatic adsorption of a group of basic proteins onto the capillary wall is significantly reduced allowing their analysis by CE. Moreover, the DMA-EPyM coating provides reproducible separations of the basic proteins with RSD values for migration times lower than 0.75% for the same day (n = 5) and lower than 3.90% for three different days (n = 15). Interestingly, the electrical charge of the coated capillary wall can be modulated by varying the pH of the running buffer which makes possible the analysis of basic and acidic proteins in the same capillary. The usefulness of this coating is further demonstrated via the reproducible separation of whey (i.e. acidic) proteins from raw milk. The coating protocol should be compatible with both CE in microchips and CE-MS of different types of proteins.  相似文献   

3.
Kok MG  de Jong GJ  Somsen GW 《Electrophoresis》2011,32(21):3016-3024
Analyte responses in CE‐ESI‐MS using negative ionization are frequently relatively low, thereby limiting sensitivity in metabolomics applications. In order to enhance the ionization efficiency of anionic metabolites, BGEs and sheath liquids (SLs) of various compositions were evaluated. Pressure‐induced infusion and CE‐MS experiments showed that addition of triethylamine (TEA) to the BGE and SL enhanced analyte intensities. A BGE consisting of 25 mM TEA (pH 11.7) and an SL of water–methanol (1:1, v/v) containing 5 mM TEA was selected, providing separation and detection of ten representative test metabolites with good reproducibility (migration time RSDs<1%) and linearity (R2>0.99). This BGE yielded lower limits of detection (0.7–9.1 μM) for most test compounds when compared with common CE‐MS methods using a BGE and SL containing ammonium acetate (NH4Ac) (25 and 5 mM, respectively). CE‐MS of human urine revealed an average amount of 231 molecular features in negative ionization mode when TEA was used in the BGE and SL, whereas 115 and 102 molecular features were found with an NH4Ac‐containing BGE and SL, employing a bare fused‐silica (BFS) and Polybrene‐dextran sulfate‐Polybrene (PB‐DS‐PB)‐coated capillary, respectively. With the CE‐MS method using TEA, about 170 molecular features were observed that were not detected with the NH4Ac‐based CE‐MS methods. For more than 82% of the molecular features that were detected with the TEA as well as the NH4Ac‐containg BGEs (i.e. common features), the peak intensities were higher using TEA with gain factors up to 7. Overall, the results demonstrate that BGEs and SLs containing TEA are quite favorable for the analysis of anionic metabolites in CE‐MS.  相似文献   

4.
Two capillary isoelectric focusing (CIEF) systems have first been optimized: one uses a bare silica capillary and 30% (v/v) of glycerol in the separation medium while the other uses a coated capillary and an aqueous background electrolyte. To perform permanent capillary coating, two neutral polymers have been compared: hydroxypropylcellulose (HPC) and polyvinylalcohol (PVA). HPC coating gave best results for electroosmotic flow (EOF) limitation on a wide pH range: as compared to a bare silica capillary, it allowed to decrease EOF by 96% at pH 7.2 after acidic and basic treatments, whereas PVA coating lead only to a 76% decrease. The glycerol CIEF system was more satisfying for the separation of model proteins classically used as pI markers. Finally, the use of "narrow pH cuts" of carrier ampholytes added to commercial ampholyte mixtures allowed increasing resolution up to a factor 2.4 at a chosen pH for the separation of pI markers and milk proteins.  相似文献   

5.
Capillary electrophoresis using diol-bonded fused-silica capillaries   总被引:1,自引:0,他引:1  
In this paper, 3-glycidoxypropyltrimethoxysilane was used to produce diol-bonded capillaries at room temperature for capillary electrophoresis (CE). A variety of standard reference compounds and authentic biological samples including ribonucleotides, peptides and proteins were used to test the columns. It was found that greatly suppressed electroosmotic flow was measured over a pH range of 3–10. Lower than 1.6% relative standard deviation (>10 runs) in migration time was observed for the analysis of test proteins. For real samples of ribonucleotides in tumor cell extracts, 1 million theoretical plates and excellent peak shapes were obtained. The high column efficiency and symmetrical peaks allowed the separation of samples with only 0.6% maximum difference in migration times. The diol-bonded fused-silica capillary columns were stable when used in a pH range of 2–8 under typical CE conditions. The column preparation method involved a simple dynamic coating procedure at room temperature, greatly simplifying the more typical static coating methods that require vacuum pumps and ovens.  相似文献   

6.
A fast method for the generation of permanent hydrophilic capillary coatings for capillary electrophoresis (CE) is presented. Such interior coating is effected by treating the surface to be coated with a solution of glutaraldehyde as cross-linking agent followed by a solution of poly(vinyl alcohol) (PVA), which results in an immobilization of the polymer on the capillary surface. Applied for capillary zone electrophoresis (CZE) such capillaries coated with cross-linked PVA exhibit excellent separation performance of adsorptive analytes like basic proteins due to the reduction of analyte-wall interactions. The long-term stability of cross-linked PVA coatings could be proved in very long series of CZE separations. More than 1000 repetitive CE separations of basic proteins were performed with stable absolute migration times relative standard deviation (RSD > 1.2%) and without loss of separation efficiency. Cross-linked PVA coatings exhibit a suppressed electroosmotic flow and excellent stability over a wide pH range.  相似文献   

7.
This article describes a new application of graphene oxide (GO) in CE based on the coating of fused silica capillary for chiral separation. The coated capillary was characterized by SEM, energy dispersive X‐ray spectroscopy, and Raman spectra. The results indicated that the capillary was coated with GO. Chiral separations were carried out in the GO‐coated capillary for the ephedrine–pseudoephedrine (E‐PE) isomers and β‐methylphenethylamine (β‐Me‐PEA) isomers at the optimal buffer conditions without any chiral selector by CE. The precision and reproducibility of GO‐coated capillary were investigated, and the RSDs of migration time (n = 6) for the E‐PE isomers were 1.35–1.41%, and 0.97–3.50% for β‐Me‐PEA isomers, respectively. The LOD for E‐PE isomers and β‐Me‐PEA isomers was 3 μM and 18 μM, respectively.  相似文献   

8.
A novel and simple coating method was developed by coating bovine serum albumin (BSA) onto the inner surface of a fused-silica capillary, to avoid the adsorption of analytes during CE. The advantage presented here was that the coating process is more simple, fast, stable, and reproducible. The coated capillary avoided the adsorption of analytes onto the inner surface of a fused-silica capillary and might be a promising candidate for separation of complex biological samples with further development. Meanwhile, the efficiencies of the coated capillary were evaluated by EOF, chromatographic peak shape, and theoretical plate number (N m?1) of RNase A. The optimal coating conditions were obtained from the results. The pH value of coating buffer PB was 4.2, the standing time was 12 h at 4 °C, and the coating concentration of BSA was 1.5 mg mL?1. The stability of the coating on the inner wall of the capillary and the reproducibility of the coated capillaries were good. The theoretical plate number values of RNase A were over 1.3 × 105 (N m?1) in the coated capillary. After successive electrophoresis for 48 h using the coated capillary, the RSD values of EOF and the theoretical plate number were 4.14 % and 9.14 %, respectively. In addition, the RSD values of EOF and the theoretical plate number (N m?1) in the coated capillaries were 13.19 % and 8.96 %, respectively. Finally, the coated capillary was successfully applied to separate the mixture of four basic proteins (RNase A, lysozyme, trypsin and myoglobin).  相似文献   

9.
CE offers the advantage of flexibility and method development options. It excels in the area of separation of ions, chiral, polar and biological compounds (especially proteins and peptides). Masking the active sites on the inner surface of a bare fused silica capillary wall is often necessary for CE separations of basic compounds, proteins and peptides. The use of capillary surface coating is one of the approaches to prevent the adsorption phenomena and improve the repeatability of migration times and peak areas of these analytes. In this study, new capillary coatings consisting of (i) derivatized polystyrene nanoparticles and (ii) derivatized fullerenes were investigated for the analysis of peptides and protein digest by CE. The coated capillaries showed excellent run‐to‐run and batch‐to‐batch reproducibility (RSD of migration time ≤0.5% for run‐to‐run and ≤9.5% for batch‐to‐batch experiments). Furthermore, the capillaries offer high stability from pH 2.0 to 10.0. The actual potential of the coated capillaries was tested by combining CE with MALDI‐MS for analysing complex samples, such as peptides, whereas the overall performance of the CE‐MALDI‐MS system was investigated by analysing a five‐protein digest mixture. Subsequently, the peak list (peptide mass fingerprint) generated from the mass spectra of each fraction was entered into the Swiss‐Prot database in order to search for matching tryptic fragments using the MASCOT software. The sequence coverage of analysed proteins was between 36 and 68%. The established technology benefits from the synergism of high separation efficiency and the structure selective identification via MS.  相似文献   

10.
Cycloaliphatic epoxy resin coating for capillary electrophoresis   总被引:3,自引:0,他引:3  
Coating the interior surface of a fused-silica capillary with a polymeric material has long been used in capillary electrophoresis (CE) to reduce or eliminate electroosmotic flow and suppress adsorption. A cycloaliphatic epoxide-based resin was bonded to silane treated capillaries and crosslinked with a curing agent. The epoxy resin coating significantly reduced electroosmotic flow over a pH range of 3-10. This coating was sufficiently hydrophilic to suppress protein adsorption. The epoxy resin coated capillary was used to separate several acidic and basic proteins and peptides. Separation efficiencies greater than 400,000 theoretical plates were achieved. The relative standard deviations in migration times for proteins were <0.8%. Speed and simplicity are important advantages of the coating procedure compared to other published coating methods.  相似文献   

11.
In this work, a CE method with bare gold nanorods (GNRs) based pseudostationary phase was developed and applied for the separation of chondroitin sulfate (CS) isomers, CS, and dermatan sulfate (DS). The separation efficiency was investigated by varying the experimental parameters such as concentration and pH of the BGE, separation voltage, internal diameter of capillary, different size, and morphology of gold nanomaterials. Results showed that different size and morphology of gold nanomaterials had different effects on the separation of CS and DS. The best separation of CS and DS was achieved in the BGE composed of aqueous 150 mmol/L (mM) ethylenediamine + 20 mM sodium dihydrogen phosphate + 30% v/v GNRs, pH 4.5, at the separation voltage of ?10 kV. Capillary was 59.2 cm in length (effective length 49 cm), 50 μm id capillary thermostated at 25°C. CE with bare GNRs used as pseudostationary phase was shown to be a suitable technique for the separation of CS and DS mixtures with wider peaks. RSD of migration time and peak area of CS and DS were 0.13, 0.14 and 0.86, 1.07%, respectively.  相似文献   

12.
Analyte–wall interaction is a significant problem in capillary electrophoresis (CE) as it may compromise separation efficiencies and migration time repeatability. In CE, self-assembled polyelectrolyte multilayer films of Polybrene (PB) and dextran sulfate (DS) or poly(vinylsulfonic acid) (PVS) have been used to coat the capillary inner wall and thereby prevent analyte adsorption. In this study, atomic force microscopy (AFM) was employed to investigate the layer thickness and surface morphology of monolayer (PB), bilayer, (PB-DS and PB-PVS), and trilayer (PB-DS-PB and PB-PVS-PB) coatings on glass surfaces. AFM nanoshaving experiments providing height distributions demonstrated that the coating procedures led to average layer thicknesses between 1 nm (PB) and 5 nm (PB-DS-PB), suggesting the individual polyelectrolytes adhere flat on the silica surface. Investigation of the surface morphology of the different coatings by AFM revealed that the PB coating does not completely cover the silica surface, whereas full coverage was observed for the trilayer coatings. The DS-containing coatings appeared on average 1 nm thicker than the corresponding PVS-containing coatings, which could be attributed to the molecular structure of the anionic polymers applied. Upon exposure to the basic protein cytochrome c, AFM measurements showed an increase of the layer thickness for bare (3.1 nm) and PB-DS-coated (4.6 nm) silica, indicating substantial protein adsorption. In contrast, a very small or no increase of the layer thickness was observed for the PB and PB-DS-PB coatings, demonstrating their effectiveness against protein adsorption. The AFM results are consistent with earlier obtained CE data obtained for proteins using the same polyelectrolyte coatings.  相似文献   

13.
A laboratory‐made INSTCoated fused‐silica capillary has been newly used for CE separation of four mixtures of proteins in sodium phosphate BGEs at pH 3.0 and 2.5, respectively. The obtained separation efficiencies range from 145 000 theoretical plates per meter for myoglobin to 1 216 000 m?1 for lysozyme. A total of 49–89% of the number of theoretical plates was obtained in a commercial polyvinyl alcohol coated capillary compared to the INSTCoated capillary under the same experimental conditions, 0–86% was obtained in a laboratory polyacrylamide‐coated capillary, and only 0–6% was obtained in an uncoated fused‐silica capillary. The RSD values for the intraday repeatability for an INSTCoated capillary were 0.1–1.0% (migration time) and 0.3–2.4% (peak area); RSD values for the interday repeatability in the same capillary are 0.6–1.4% (migration time) and 2.4–5.5% (peak area); RSD values for interday repeatability between different capillaries equaled 1.7–2.1% (migration time) and 2.8–10.9% (peak area). The INSTCoated capillary has been further used for rapid determination of globin chains isolated from red blood cells. A separation of α and β chains prepared from adult blood has been completed in 3 min with a peak resolution of 1.3, and the separation of α and Gγ chains prepared from newborn blood took 3 min with a peak resolution of 3.6.  相似文献   

14.
The usefulness of a noncovalent capillary coating consisting of two layers of oppositely charged polymers for the separation of peptides with capillary electrophoresis (CE) was studied. Capillaries were coated simply by subsequently flushing with solutions of 1% m/v Polybrene and 1% v/v poly(vinylsulfonate) (PVS) forming a bilayer, which showed to produce a strong and highly reproducible electroosmotic flow (EOF) at low pH. Using this coating in combination with a background electrolyte (BGE) containing sodium phosphate (pH 2.5) and 0.01% v/v PVS, initially broadened and overlapping peaks were obtained for some test peptides. By omitting the PVS from the BGE, the peak width and shape of the peptides improved resulting in baseline separation. A systematic study of the influence of the BGE composition showed that considerable further enhancement of the separation efficiency was achieved by increasing the ionic strength of the BGE. Using a BGE of 200 mM tris(hydroxymethyl)aminomethane (Tris)-phosphate (pH 2.5) plate numbers for the peptides were in the 300 000-600 000 range and the relative standard deviation of the peptide migration times was less then 0.3% (n = 5). The use of Tris-phosphate instead of sodium phosphate allowed the current to stay within acceptable limits when 30 kV was used as separation voltage. Overall, the bilayer coating showed a remarkable EOF repeatability, as well as long-term stability. Compared to bare fused-silica capillaries the intraday and interday repeatability of migration times was very favorable and coated capillaries could be used for over a month performing analyses with low and high ionic strength BGEs without any performance deterioration. The usefulness of the bilayer-coated capillaries for the analysis of positively charged peptides was demonstrated by the fast and efficient separation of various closely related enkephalins and the baseline separation of an isomeric peptide/peptoid couple exhibiting efficiencies of over 550 000 plates.  相似文献   

15.
For the first time, a capillary electrophoretic (CE) method with sample stacking induced by a reverse migrating pseudostationary phase (SRMP) technique has been developed and validated for sensitive determination of phenobarbital (PB) and its p-hydroxyphenobarbital (PHPB) metabolite in rat urine samples. Separation and determination were optimized on a fused-silica capillary with a total length of 50 cm (effective length 40 cm) and 75 μm ID. The microemulsion background electrolyte consisted of 0.8% (v/v) ethyl acetate, 6.6% (v/v) butan-2-ol, 1.0% (v/v) acetonitrile, 2.0% (w/v) sodium n-dodecyl sulfate (SDS), and 89.6% (v/v) of 7.5 mM ammonium formate at pH 8. When this preconcentration technique was used, the sample stacking and the separation processes took place successively with changing the voltage with an intermediate polarity switching step. For practical application, a solid-phase extraction (SPE), C(18) sorbent with n-hexane/ethyl acetate (1?:?1%, v/v) as the elution solvent was used for sample purification and concentration. The SPE method gave good extraction yields for all the analytes, with absolute recovery values of 96.9% and 99.1% for PB and PHPB, respectively. The regression equations for PB and PHPB showed excellent linearity over a concentration range of 55-1386 ng mL(-1) for PB and PHPB (r = 0.998). The developed microemulsion electrokinetic capillary chromatography (MEEKC) method for separation of the studied compounds with SRMP as the electrophoretic preconcentration technique allowed detection limits in urine samples at 16.8 ng mL(-1) for PB and PHPB which are 15-fold lower than the reported CE method in the literature. The precision results, expressed by the intra-day and inter-day relative standard deviation (RSD) values range from 3.6 to 7.1% (repeatability) and from 3.2 to 7.2% (intermediate precision) for PB and PHPB, respectively, which were in line with Food and Drug Administration (FDA) criteria.  相似文献   

16.
A rapid, precise, accurate, and robust method using capillary electrophoresis (CE) with dynamically coated capillaries for the analysis of the major opium alkaloids in opium is presented. Dynamic coating of the capillary surface is accomplished using a commercially available reagent kit (polycation coating followed by polyanion coating). The addition of dual cyclodextrins (hydroxypropyl-beta-cyclodextrin and dimethyl-beta-cyclodextrin) to the run buffer imparts excellent selectivity for the opium alkaloids. For the determination of morphine, papaverine, codeine, noscapine and thebaine in opium gum and opium latex samples (using tetracaine as an internal standard) good agreement with values obtained by gradient high-performance liquid chromatography is obtained. Compared to the latter technique, CE affords better resolution with significantly faster analysis time (12 min versus 29 min). Dynamically coated capillaries, which give rise to a relatively high and robust electroosmotic flow (EOF) at the background electrolyte pH of 2.5, allow for rapid analysis and excellent migration time and peak area precision (RSDs < or = 0.12% and < or = 1.2%, respectively). Reproducible separations (relative migration times) for over 500 samples have been obtained on a single capillary. The nature of the injection solvent, the injection time and the contents of the waste vials have a profound effect on the pressure injection precision of the relatively hydrophobic solutes. The CE conditions reported in this study are also applicable to the analysis of lysergic acid diethylamide (LSD) exhibits.  相似文献   

17.
The first application of charged polymer‐protected gold nanoparticles (Au NPs) as semi‐permanent capillary coating in CE‐MS was presented. Poly(diallyldimethylammonium chloride) (PDDA) was the only reducing and stabilizing agent for Au NPs preparation. Stable and repeatable coating with good tolerance to 0.1 M HCl, methanol, and ACN was obtained via a simple rinsing procedure. Au NPs enhanced the coating stability toward flushing by methanol, improved the run‐to‐run and capillary‐to‐capillary repeatabilities, and improved the separation efficiency of heroin and its basic impurities for tracing geographical origins of illicit samples. Baseline resolution of eight heroin‐related alkaloids was achieved on the PDDA‐protected Au NPs‐coated capillary under the optimum conditions: 120 mM ammonium acetate (pH 5.2) with addition of 13% methanol, separation temperature 20°C, applied voltage ?20 kV, and capillary effective length 60.0 cm. CE‐MS analysis with run‐to‐run RSDs (n=5) of migration time in the range of 0.43–0.62% and RSDs (n=5) of peak area in the range of 1.49–4.68% was obtained. The established CE‐MS method would offer sensitive detection and confident identification of heroin and related compounds and provide an alternative to LC‐MS and GC‐MS for illicit drug control.  相似文献   

18.
We evaluated the potential of CE to analyse different isoforms of unphosphorylated recombinant tau protein and for separating one phosphorylated tau from the respective unphosphorylated protein. Different capillary coatings such as polyacrylamide, poly‐(ethylene oxide) and polybrene (PB) were evaluated to overcome the poor efficiencies obtained with fused‐silica capillary. Although peak asymmetry values were quite similar for the three investigated coatings, the peak efficiencies were 35‐fold and 5‐fold higher with PB coating than with polyacrylamide and poly(ethylene oxide) coatings, respectively. The recovery percentage (over 97%) was satisfactory and confirmed the efficacy of PB coating to limit the adsorption of tau protein to capillary walls. Moreover, PB coating produced higher repeatability for migration times (RSD values <1.2%) in comparison to the neutral coatings. The potential of PB‐modified capillary in producing high resolutive separations of one phosphorylated tau isoform from its unphosphorylated counterpart and of a mixture of phosphorylated and unphosphorylated tau peptides was demonstrated with 50 mM phosphate buffer pH 3.0. The separation of unphosphorylated tau isoform 352 (Tau‐352) from Tau‐352 phosphorylated in vitro by the mitogen‐activated protein kinase ERK2, was accomplished in less than 15 min.  相似文献   

19.
Mizzen CA  McLachlan DR 《Electrophoresis》2000,21(12):2359-2367
Existing methods for the analysis of histone H1 by capillary electrophoresis (CE) employ acidic buffers (pH <3.0) to suppress silanol ionization and minimize the loss of these extremely basic proteins by adsorption to capillary walls. Here we describe the use of Polybrene (PB) as a dynamic modification reagent in a simple procedure that facilitates the analysis of chicken H1 at neutral pH. PB is adsorbed to the inner surfaces of capillaries to render them cationic prior to use and a low concentration of PB is included in the electrolyte to replenish the coating during use. Inclusion of ethylenediaminetetraacetic acid (EDTA) in the electrolyte results in the assembly of a dynamic cation-exchange layer upon the immobilized PB that influences the relative mobilities of H1 variants. The six nonallelic variants of H1 known in this species as well as certain allelic variants are resolved. Because the procedure is effective in preventing the adsorption of proteins as basic as H1 at neutral pH, this strategy should facilitate CE analyses of many basic proteins under conditions that maintain their native conformation.  相似文献   

20.
In this work, a new physically adsorbed coating for CE is presented. This coating is based on a poly(N,N‐dimethylacrylamide‐co‐4‐(ethyl)‐morpholine methacrylamide) (DMA/MAEM) copolymer synthesized in our laboratory. It is demonstrated that the direction and magnitude of the EOF in CE can be modulated by varying the composition of the DMA/MAEM copolymer and the type and pH of the BGE. Moreover, the DMA/MAEM coating provides %RSDn = 5 values for migration times lower than 0.9% for the same capillary and day, whereas the %RSDn = 25 obtained for the interday assay was lower than 2.9%. The stability of the coating procedure is also tested between capillaries obtaining %RSDn = 15 values lower than 2.9%, demonstrating that this physically adsorbed copolymer gives rise to a stable and reproducible coating in CE. Finally, the usefulness of this new cationic copolymer as CE coating is demonstrated through different applications. Namely, it is demonstrated that the CE separation of basic proteins, nucleotides and organic acids is achieved in a fast and easy way by using the DMA/MAEM coated capillary. The use of fused bare silica capillaries did not allow the separation of these compounds under the same analytical conditions. These results demonstrate that this type of coating in CE provides the option of using BGEs that are useless when utilized together with bare silica capillaries making wider the application and possibilities of this analytical technique.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号