首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Two in‐line enrichment procedures (large volume sample stacking (LVSS) and field amplified sample injection (FASI)) have been evaluated for the CZE analysis of haloacetic acids (HAAs) in drinking water. For LVSS, separation on normal polarity using 20 mM acetic acid–ammonium acetate (pH 5.5) containing 20% ACN as BGE was required. For FASI, the optimum conditions were 25 s hydrodynamic injection (3.5 kPa) of a water plug followed by 25 s electrokinetic injection (?10 kV) of the sample, and 200 mM formic acid–ammonium formate buffer at pH 3.0 as BGE. For both FASI and LVSS methods, linear calibration curves (r2>0.992), limit of detection on standards prepared in Milli‐Q water (49.1–200 μg/L for LVSS and 4.2–48 μg/L for FASI), and both run‐to‐run and day‐to‐day precisions (RSD values up to 15.8% for concentration) were established. Due to the higher sensitive enhancement (up to 310‐fold) achieved with FASI‐CZE, this method was selected for the analysis of HAAs in drinking water. However, for an optimal FASI application sample salinity was removed by SPE using Oasis WAX cartridges. With SPE‐FASI‐CZE, method detection limits in the range 0.05–0.8 μg/L were obtained, with recoveries, in general, higher than 90% (around 65% for monochloroacetic and monobromoacetic acids). The applicability of the SPE‐FASI‐CZE method was evaluated by analyzing drinking tap water from Barcelona where seven HAAs were found at concentration levels between 3 and 13 μg/L.  相似文献   

2.
A simple, sensitive, specific, and cost‐effective analytical methodology was developed for the analysis of human plasma samples spiked with imatinib by CZE with on‐line UV detection in the context of Therapeutic Drug Monitoring. Several analytical conditions such as the ionic strength (I) and the pH of the BGE composed of citric acid and ε‐amino caproic acid were studied in regards of the presence of sodium chloride (NaCl) in plasma samples (1% m/v). Computer simulations (Simul software) were used to confirm the experimental results and to understand imatinib electrophoretic behavior in the presence of NaCl. Furthermore, the advantages of adding ACN to the sample containing NaCl to combine efficient protein precipitation and on‐line CZE stacking of imatinib were demonstrated. LOD and LOQ values of 48 and 191 ng/mL were obtained from plasma sample supernatant after protein precipitation with ACN, which is much lower than mean imatinib plasma level observed for patients treated by imatinib mesylate (about 1000 ng/mL). Good linearity was obtained in the concentration range 191–5000 ng/mL (R2 > 0.997). RSD of less than 1.68% and 2.60% (n = 6) for migration times and corrected peak areas, respectively, were observed at the LOQ.  相似文献   

3.
A rapid, high resolution, and low sample consumption CZE method is developed for peptide nucleic acid (PNA) analysis for the first time. 30% v/v acetonitrile in PNA sample and 20% v/v acetonitrile in 50 mM borax‐boric acid (pH 8.7) as BGE were employed after optimization. The calibration curves were linear for PNA concentration ranging from 1 to 50 μmol/L. LOD and LOQ of PNA were 0.2 and 1.0 μmol/L, respectively. Since the commercially available reagent gives rise to huge PNA peak and an apparent impurity peak, the purity of PNA was evaluated to be about 81.4% by CZE method, obviously lower than the supplier's purity value of 99.9% evaluated by RP–HPLC, and also lower than 94.8% determined with RP–HPLC by our research group. The CZE method takes only 5 min, needs only 90 nL PNA, much less than 20 min and 20 μL PNA in RP–HPLC method. Moreover, the CZE method is applicable for the analysis of glutamic acid modified and lysine modified PNAs, they show different migration time with their corresponding complementary PNAs. Our results show CZE provides a new choice for PNA and modified PNA analysis, also their purity or quality evaluation.  相似文献   

4.
The determination of ethyl glucuronide (EtG), a marker of recent alcohol consumption, in human serum by hyphenation of capillary ITP (CITP) and CZE is reported. For CITP step, 1 x 10(-2) M hydrochloric acid adjusted with epsilon-aminocaproic acid (EACA) to pH 4.4 was used as the leading electrolyte, and 1 x 10(-2) M nicotinic acid with EACA, pH 4.4, was used as the terminating electrolyte (TE). All electrolytes contained 0.2% hydroxypropylcellulose to suppress electroosmosis. In CITP, EtG was separated from fast serum macrocomponents chloride, phosphate, lactate, and acetate. Zones of microcomponents including EtG that migrated between acetate and nicotinate were forwarded to the second capillary filled with a BGE identical with the TE. Conductivity detection was used in the CITP step. Sensitive detection in the CZE step was performed using indirect spectrophotometric detection at 254 nm. The assay is based on a 1:5 dilution of serum with deionized water and has a concentration LOD for EtG in diluted sample of 9.8 x 10(-9) M. The method was used for the determination of EtG in sera of volunteers consuming alcohol.  相似文献   

5.
三角形法和四面体法优化选择毛细管区带电泳背景电解质   总被引:1,自引:1,他引:1  
孙国祥  宋文璟  林婷 《色谱》2008,26(2):232-236
建立了两种高效、快速的毛细管区带电泳背景电解质(BGE)的优化方法三角形优化法和四面体优化法。以色谱指纹图谱指数F和色谱指纹图谱相对指数Fr作为评价毛细管电泳分析系统的目标函数,以雪莲药材水提取液为样品,考察一定浓度的硼砂、硼酸、磷酸氢二钠和磷酸二氢钠溶液按三角形优化法和四面体优化法构成背景电解质时对样品的分离情况,通过添加有机改性剂和调节pH进行再优化。用三角形法优化出以50 mmol/L硼砂-含3%乙腈的150 mmol/L磷酸二氢钠(体积比为1∶1)作为BGE时分离效果最佳,用四面体法优化出以50 mmol/L硼砂-150 mmol/L磷酸二氢钠-200 mmol/L硼酸(体积比为1∶1∶2,用0.1 mol/L氢氧化钠调pH 8.55)作为BGE时分离效果最佳,分别获得28个和25个电泳峰。所建立的方法操作简捷,适用于中药材水提取液或醇提取液的毛细管区带电泳BGE的选择。  相似文献   

6.
The analysis of ethyl glucuronide (EtG), a marker of recent alcohol consumption, in serum with an optimized CZE assay is reported. The method uses a 0.1-mm id fused-silica capillary of 50 cm effective length that is coated with linear polyacrylamide, a pH 4.4 nicotinic acid/epsilon-aminocaproic acid (EACA) BGE, reversed polarity and indirect analyte detection. The assay is based on a 1:1 dilution of serum with deionized water and has LODs for EtG, lactate and acetate of 3.8 x 10(-7) M, 2.60 x 10(-6 )M and 2.18 x 10(-6 )M, respectively. Separation of EtG from endogenous macro- and microcomponents (anionic serum components of high and low concentration, respectively) and its quantification are shown to be possible for a wide range of lactate (stacker) and acetate (destacker) concentrations, macrocomponents that have an impact on the CZE behavior of EtG and that change after intake of ethanol. The assay has been successfully applied to the analysis of EtG, lactate and acetate in (i) sera of volunteers that ingested known amounts of alcohol and (ii) samples of patients that were classified (teetotalers and social drinkers vs. alcohol abusers) via analysis of carbohydrate-deficient transferrin.  相似文献   

7.
CZE was assayed for the separation of carbamate pesticides susceptible to protonation (Pirimicarb, Carbendazim). Different electrophoretic media with high organic contents were explored, adequate separation and resolution being achieved when a BGE based on ACN with acetic acid in the presence of SDS as an ionic additive was used. With a view to increasing the sensitivity of the method, an in-capillary SPE step prior to the electrophoretic separation was developed. We employed a monolithic polymer formed in situ within the capillary as a medium for analyte retention. The synthesized monolithic bed exhibited high porosity and allowed samples to be loaded at flow rates of about 65 microL/min by applying a pressure of 12 bar. A 5-cm length of monolithic sorbent was used to preconcentrate the target analytes from aqueous samples. The analytes retained were eluted from the polymeric phase directly in the separation capillary with the same electrophoretic medium used for their further separation by CZE. For a 15-min preconcentration time, the in-line SPE-CZE approach proposed here permitted the determination of these pesticides in drinking water at a concentration level of 0.1 microg/L, as demanded by current EU legislation.  相似文献   

8.
A method for the resolution of a peptides mixture including hepcidin‐25, an iron metabolism marker, was developed by CE‐ESI‐MS. Several strategies were tested to optimize peptide separation, such as the addition of cyclodextrins or organic solvents in the BGE or the use of coated capillaries. Best results in terms of resolution, symmetry and efficiency were obtained with a BGE made of 500 mM ammonium acetate pH 4.5/ACN 70:30 v/v. Using the methodology of experimental design, BGE concentration, sheath liquid composition and MS‐coupling parameters were then optimized in order to obtain the best signal intensity for hepcidin. Finally, a 225 mM BGE and a sheath liquid composed of isopropanol/water 80:20 v/v containing 0.5% v/v formic acid were selected as it constitutes the best compromise for selectivity, peak shape and sensitivity.  相似文献   

9.
A CZE with near‐infrared (NIR) LIF detection method has been developed for the analysis of six low molecular weight thiols including glutathione, homocysteine, cysteine, γ‐glutamylcysteine, cysteinylglycine, and N‐acetylcysteine. For this purpose, a new NIR fluorescent probe, 1,7‐dimethyl‐3,5‐distyryl‐8‐phenyl‐(4'‐iodoacetamido)difluoroboradiaza‐s‐indacene was utilized as the labeling reagent, whose excitation wavelength matches the commercially available NIR laser line of 635 nm. The optimum procedure included a derivatization step of the free thiols at 45°C for 25 min and CZE analysis conducted within 14 min in the running buffer containing 16 mmol/L pH 7.0 sodium citrate and 60% v/v ACN. The LODs (S/N = 3) ranged from 0.11 nmol/L for N‐acetylcysteine to 0.31 nmol/L for γ‐glutamylcysteine, which are better than or comparable to those reported with other derivatization‐based CE‐LIF methods. As the first trial of NIR CE‐LIF method for thiol determination, the practical application of the proposed method has been validated by detecting thiols in cucumber and tomato samples with recoveries of 96.5–104.3%.  相似文献   

10.
A sensitive capillary electrophoretic method featuring spectrophotometric detection using a commercial Z‐cell was devised for the assay of 8‐hydroxy‐2′‐deoxyguanosine (8OHdG) in human urine. Solid‐phase extraction (SPE) based on hydrophilic‐lipophilic‐balanced RP sorbent was utilized for urine sample pretreatment and analyte preconcentration. The separation was carried out in conventional fused‐silica capillaries employing a Z‐cell with hydrodynamic sample injection (at 50 mbar for 12 s). The BGE (pH* 9.2, adjusted with 1 M NaOH) contained 0.15 M boric acid and 10% v/v ACN. The detection wavelength was 282 nm. The calibration curve for 8OHdG (measured in spiked urine) was linear in the range 10–1000 ng/mL; R2 = 0.9993. The LOD was 3 ng/mL (11 nmol/L) of 8OHdG. Determination of the 8OHdG urinary levels was possible even in healthy individuals.  相似文献   

11.
Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are powerful markers for alcohol intake and abuse. Several analytical procedures for the quantification of EtG and EtG in serum and urine have been developed so far. Many of the published methods show limits of detections (LODs) or limits of quantifications (LOQs) for EtG in urine within the range of 0.1 mg/L or higher. Since this is the actual cutoff value for proving abstinence in Germany, problems may occur if urine samples are highly diluted. In this paper, the validation of a highly sensitive, fast and simple LC-MS-MS for the determination of EtG and EtS in urine is described. The calibration curves for EtG and EtS is linear over the whole range (0.025-2.0 mg/L). Very low detection limits can be achieved (LOD: EtG 0.005 mg/L, EtS 0.005 mg/L; and LOQ: EtG 0.019 mg/L, EtS 0.015 mg/L). All data for selectivity, precision and accuracy, recovery, as well as for the processed sample and the freeze/thaw stability, comply with the guidelines of the German Society of Toxicological and Forensic Chemistry. Strong matrix-related effects can be compensated for by using an internal standard. Finally, the applicability of the procedure is proven by analysis of 87 human urine samples and by successful participation in interlaboratory comparison tests.  相似文献   

12.
A method for sensitive determination of five priority haloacetic acids in drinking water has been developed for the first time based on electromembrane extraction (EME) prior to CZE with capacitively coupled contactless conductivity detection (CZE‐C4D). The target analytes were extracted from 10 mL of the sample solution (donor phase), through the supported liquid membrane (using a polypropylene membrane supporting 1‐octanol), and into 10 µL of 50 mmol/L NaAc solution (acceptor phase). The extracted solution was directly analyzed by CZE‐C4D without derivatization. Several factors that affect separation, detection and extraction efficiency were investigated. Under the optimum conditions, five haloacetic acids (monochloroacetic acid, dichloroacetic acid, trichloroacetic acid, monobromoacetic acid, and dibromoacetic acid) could be well separated from other components coexisting in water samples within 23 min, exhibiting a linear calibration over two orders of magnitude (r?0.9943); the enrichment factors at 430–671 were obtained in a 30 min of extraction, and the limits of detection were in the range of 0.17–0.61 ng/mL. The intraday relative standard deviations for peak areas investigated at 10 ng/mL were between 1.2% and 9.7% for the combined EME‐CZE‐C4D procedure. This approach offers an attractive alternative to the officially proposed method for purified drinking water analysis, which requires derivatization procedure prior to gas chromatography analysis.  相似文献   

13.
Erny GL  Marina ML  Cifuentes A 《Electrophoresis》2007,28(17):2988-2997
Zein proteins are a complex mixture of polypetides that belong to the alcohol-soluble storage proteins group (prolamines) in corn. These proteins constitute about 50-60% of the total endosperm protein and are classified in different groups on the basis of differences in their solubility and sequence. Among them, zein proteins are considered the majority group showing a high tendency to aggregate what makes their analysis by any analytical method very difficult. Thus, CZE of these proteins requires the use of very complex BGEs noncompatible with online ESI-MS analysis. The aim of this work was to find a new BGE for the CZE separation of zein protein fully compatible with ESI-MS while providing further light on the complex CZE separation of aggregatable proteins. Thus, it is demonstrated in this work that efficient and reproducible CZE separations of zein proteins can be achieved by using a BGE composed of water, ACN, formic acid and ammonium hydroxide. Besides, it is shown that zein analysis is significantly improved by including the effect of an ammonium gradient during their separation. It is experimentally verified that the ammonium gradient can easily be achieved in CZE by either working with a sample zone with a low concentration of ammonium and a BGE with a high concentration, or conversely, working with a sample zone with high ammonium concentration and a BGE with low concentration of ammonium, giving rise in both cases to a significant improvement in the CZE separation of these proteins. It is demonstrated that this procedure can give rise to efficiency improvements of up to 20-fold in the CZE separation of zein proteins. Under optimized conditions, 20 proteins could be separated with average efficiencies higher than 400 000 theoretical plates/m. Some possible explanations of this effect are discussed including stacking, protein-capillary wall adsorption, protein solubility and protein-salt interactions.  相似文献   

14.
Dispersive liquid–liquid microextraction (DLLME) was combined for the first time with NACE‐UV for the selective determination of eight fluoroquinolone antibiotics (lomefloxacin, levofloxacin, marbofloxacin, ciprofloxacin, sarafloxacin, enrofloxacin, danofloxacin and difloxacin) in mineral and run‐off waters. Field‐enhanced sample injection was carried out in order to improve the sensitivity, whereas pipemidic acid was used as internal standard. The BGE that provided complete separation of the eight analytes and the internal standard was composed of 3 M acetic acid, 49 mM ammonium acetate in 55:45 v/v methanol:ACN. Optimum DLLME conditions (extraction of 5 mL of water at pH 7.6 with 685 μL of CHCl3 and 1250 μL of ACN, extractant and disperser solvents, respectively) were achieved by means of experimental design methodology. Calibration curves of the whole method were obtained with correlation coefficients (R) higher than 0.994 in all cases. An accuracy and precision study was carried out at different levels of concentration, finding that there were no significant differences (Student's t‐test) between real and spiked concentrations.  相似文献   

15.
Caslavska J  Jung B  Thormann W 《Electrophoresis》2011,32(13):1760-1764
CZE coupled to sheath liquid-based electrospray ionization (ESI) and multiple-stage ion trap mass spectrometry (MS(n) ) was used for the confirmation analysis of ethyl glucuronide (EtG) and ethyl sulfate (EtS) in human serum and urine collected after intake of alcoholic beverages. Electrophoretic separations were performed in uncoated fused-silica capillaries using a pH 9.5 ammonium acetate background electrolyte and normal polarity. MS detection of EtG and EtS occurred after negative ionization using a spray liquid containing 0.5%?v/v ammonia in isopropanol/water (60:40%, v/v). CZE-MS and CZE-MS2 results obtained after injection of solid-phase extracts for EtG and EtS and of diluted urine confirmed the presence of EtG and EtS in samples whose levels were previously determined by CZE with indirect UV detection. Detection limits of each compound were estimated to be around 2.0 (injection of diluted urine) and 0.2?μg/mL (extracts).  相似文献   

16.
Sun G  Ding G 《色谱》2011,29(10):1020-1026
采用毛细管区带电泳法建立了逍遥丸(Xiaoyao Pill, XYP)的毛细管电泳指纹图谱(CEFP)。运用正方形优化法,以色谱指纹图谱分离量指数(RF)为优化的目标函数,对建立指纹图谱的实验条件进行了优化,确定了最佳背景电解质(BGE)溶液50 mmol/L硼砂-50 mmol/L磷酸氢二钠-150 mmol/L磷酸二氢钠-50 mmol/L碳酸氢钠(1:1:1:5, v/v/v/v; pH 7.40)、紫外检测波长228 nm、运行电压12 kV、重力进样25 s (高度14 cm)的分离检测条件。采用未涂层石英毛细管(70 cm×75 μm,有效分离长度57 cm)分离,以咖啡酸色谱峰为参照,确定13批逍遥丸样品的21个共有指纹峰。通过聚类分析确定用其中10批样品生成对照CEFP,以此为标准用系统指纹定量法鉴别13批逍遥丸的质量,结果显示: S3号样品的化学成分数量和分布比例不合格,S10和S12号样品含量明显偏高,其余批次质量均合格。所建立的正方形优化法操作简便,适用于中药的毛细管区带电泳BGE的选择;所建立的逍遥丸CEFP具有较好的精密度和重现性,可以为逍遥丸的质量控制提供新的参考。  相似文献   

17.
A rapid method for the simultaneous determination of several non-steroidal anti-inflammatory drugs (NSAIDs) in human plasma and urine was developed using transient pseudo-isotachophoresis (ITP) in capillary zone electrophoresis (CZE). The influence of different parameters on resolution and preconcentration efficiency, such as background electrolyte (BGE) composition, sample injection, sample matrix composition, and pH, were studied to optimize the transient pseudo-ITP performance. Optimized conditions were a BGE consisting of 100 mM Na2B4O7 in 10% aqueous MeOH solution and hydrodynamic injection of the sample at 50 mbar for 90 s. The sample was prepared in a solution mixture of 1% NaCl/ethanol (30:70 v/v) at pH 10. Our results show that this simple strategy offers improved sensitivity compared to conventional CZE analysis, reaching a 45-fold preconcentration factor. The detection limits (LODs) were as low as 0.07 mg/L for standard samples with good repeatability (values of relative standard deviation, %RSD < 11%). The method was applied to the analysis of NSAIDs in biological samples. Validation for human plasma and urine samples demonstrated good linearity, low detection limits, and satisfactory repeatability values.  相似文献   

18.
Fung YS  Lau KM 《Electrophoresis》2003,24(18):3224-3232
To meet the need for a new and validated analytical method for simultaneous determination of inorganic and organic acid anions in beverage drinks, a capillary zone electrophoresis (CZE) procedure had been developed based on a new background electrolyte (BGE) system containing 3 mmol/L 1,3,5-benzenetricarboxylic acid (BTA), 15 mmol/L tris(hydroxymethyl)aminomethane and 1.5 mmol/L tetraethylenepentamine (TEPA) at pH 8.4. Baseline separation of anions commonly found in beverage drinks could be achieved in less than 14 min with indirect UV detection at 240 nm. Comigration problems for hydroxycarboxylic acids could be solved using TEPA as BGE additive. The results indicate excellent repeatability for migration time (RSD, 0.27-0.67%, n = 5) and good precision for both peak height (RSD, 3.2-4.2%, n = 5) and peak area (RSD, 3.1-4.5%, n = 5). Under the optimized conditions and using corrected peak area for quantitation, an excellent linear dynamic range (with correlation coefficient > 0.997 in a concentration range from 0.005 to 2.0 mmol/L) and low detection limit (1-4 micro mol/L) were obtained for all the anions investigated. The applicability and reliability of the CE procedure developed were established by parallel method determination using established ion chromatography procedure for the analysis of inorganic and organic acid anions in orange juice and wine samples. Our CZE procedure provided a sensitive and economic technique for simultaneous determination of inorganic and organic acid anions in orange juice, red and white wine samples.  相似文献   

19.
This study describes a method for the simultaneous determination of 12 synthetic cannabinoids by MEKC–MS/MS using a volatile surfactant (ammonium perfluorooctanoate) as a constituent of the micellar pseudostationary phase. Although most synthetic cannabinoids comigrated by a CZE method, sufficient separation could be achieved by the proposed method. The best separation was made possible by 50 mM ammonium perfluorooctanoate in 20% v/v acetonitrile/water (apparent pH* 9.0) as the BGE, followed by MS detection using a sheath liquid composed of 5 mM ammonium formate in 50% v/v methanol/water mixed hydro‐organic solvent. The standard calibration curve for all analytes showed good linearity (r > 0.99). Satisfactory recoveries, ranging from 89.5 to 101.7%, were obtained. The LODs were 6.5–76.5 μg/g for the target analytes. This method appears to be a useful tool for the identification of synthetic cannabinoids in illegal herbal incense blends.  相似文献   

20.
A direct, versatile method for the determination of ethyl glucuronide (EtG), a biomarker of ethanol consumption, in urine has been developed using reversed-phase liquid chromatography with pulsed electrochemical detection (PED). EtG and methyl glucuronide (MetG), which serves as an internal standard, are readily separated using a mobile phase consisting of 1% acetic acid/acetonitrile (98/2, v/v). Post-column addition of NaOH allows for the detection of all glucuronides using PED at a gold working electrode. Upon optimization, EtG was found to have a limit of detection of 0.03 μg/mL (7 pmol; 50 μL injection volume) and repeatability at the limit of quantitation of 1.7%R.S.D. (relative standard deviation). Solid-phase extraction (SPE) using an aminopropyl phase was used to remove interferents in urine samples prior to their analysis. Compound recovery following SPE was approximately 50 ± 2%. The forensic utility of this method was further validated by the analysis of 29 post-mortem urine specimens, whose results agreed strongly with certified determinations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号