首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 984 毫秒
1.
An electrochemical DNA sensing film was constructed based on the multilayers comprising of poly‐L ‐lysine (pLys) and Au‐carbon nanotube (Au‐CNT) hybrid. A precursor film of mercaptopropionic acid (MPA) was firstly self‐assembled on the Au electrode surface. pLys and Au‐CNT hybrid layer‐by‐layer assembly films were fabricated by alternately immersing the MPA‐modified electrode into the pLys solution and Au‐CNT hybrid solution. Cyclic voltammetry was used to monitor the consecutive growth of the multilayer films by utilizing [Fe(CN)6]3?/4? and [Co(phen)3]3+/2+ as the redox indicators. The outer layer of the multilayer film was the positively charged pLys, on which the DNA probe was easily linked due to the strong electrostatic affinity. The hybridization detection of DNA was accomplished by using methylene blue (MB) as the indicator, which possesses different affinities to dsDNA and ssDNA. Differential pulse voltammetry was employed to record the signal response of MB and determine the amount of the target DNA sequence. The established biosensor has high sensitivity, a relatively wide linear range from 1.0×10?10 mol/L to 1.0×10?6 mol/L and the ability to discriminate the fully complementary target DNA from single or double base‐mismatched DNA. The sequence‐specific DNA related to phosphinothricin acetyltransferase gene from the transgenically modified plants was successfully detected.  相似文献   

2.
The surface of a gold (Au) disk electrode was modified with a self‐assembled monomolecular layer of dithiobis(4‐butylamino‐m‐phenylboronic acid) (DTBA‐PBA) to prepare L ‐lactate‐sensitive electrodes. The DTBA‐PBA‐modified electrodes exhibited an attenuated cyclic voltammogram (CV) for the Fe(CN)63? ion in the presence of L ‐lactate, as a result of the formation of phenylboronate ester of L ‐lactate accompanied with the addition of OH? ion to the boron atom. In other words, the negatively charged DTBA‐PBA monolayer blocked the electrode surface from the access of the Fe(CN)63?/4? ions. Thus, the DTBA‐PBA monolayer‐modified Au electrode can be used for determining L ‐lactate on the basis of the change in redox current of Fe(CN)63?/4? ions. The calibration graph useful for determining 1–30 mM L ‐lactate was obtained.  相似文献   

3.
《Electroanalysis》2006,18(5):471-477
The precursor film was first formed on the Au electrode surface based on the self‐assembly of L ‐cysteine and the adsorption of gold colloidal nanoparticles (nano‐Au). Layer‐by‐layer (LBL) assembly films of toluidine blue (TB) and nano‐Au were fabricated by alternately immersing the electrode with precursor film into the solution of toluidine blue and gold colloid. Cyclic voltammetry (CV) and quartz crystal microbalance (QCM) were adopted to monitor the regular growth of {TB/Au} bilayer films. The successful assembly of {TB/Au}n films brings a new strategy for electrochemical devices to construct layer‐by‐layer assembly films of nanomaterials and low molecular weight materials. In this article, {TB/Au}n films were used as model films to fabricate a mediated H2O2 biosensor based on horseradish peroxidase, which responded rapidly to H2O2 in the linear range from 1.5×10?7 mol/L to 8.6×10?3 mol/L with a detection limit of 7.0×10?8 mol/L. Morphologies of the final assembly films were characterized with scanning probe microscopy (SPM).  相似文献   

4.
《Electroanalysis》2006,18(16):1627-1630
The surface of a gold (Au) electrode was coated with layer‐by‐layer (LbL) thin films composed of poly(vinyl sulfate) (PVS) and different type of poly(amine)s including poly(allylamine) (PAH), poly(ethyleneimine) (PEI) and poly(diallyldimethylammonium chloride) (PDDA) and redox properties of ferricyanide ion ([Fe(CN)6]3?) on the LbL film‐coated Au electrodes were studied. The LbL film‐coated electrodes exhibited redox response to [Fe(CN)6]3? ion when the outermost surface of the LbL film was covered with the cationic poly(amine)s while virtually no response was observed on the LbL film‐coated electrodes whose outermost surface was covered with PVS due to an electrostatic repulsion between [Fe(CN)6]3? ion and the negatively‐charged PVS layer. The redox properties of [Fe(CN)6]3? ion on the LbL film‐coated electrodes significantly depended on the type of polycationic materials in the LbL film. The LbL film‐coated electrodes which had been immersed in the [Fe(CN)6]3? solution for 15 min exhibited redox response even in a [Fe(CN)6]3? ion‐free buffer solution, suggesting that [Fe(CN)6]3? ion is confined in the films. In the buffer solution, redox peaks were observed between +0.1 and 0.4 V depending on the type of polycations in the film. Thus, [Fe(CN)6]3? ion can be confined in the film and the redox potential is polycation‐dependent.  相似文献   

5.
Qingfen Luan  Jun Li  Xin Yao 《Electroanalysis》2009,21(16):1799-1804
(PDDA/CdTe)n layer‐by‐layer (LBL) film immobilized with Fe(CN)63? was fabricated on the gold electrode. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used to investigate the electrochemical properties of this film. The peak current of the immobilized Fe(CN)63? increased as the number of the bilayers increased and was proportional to the scan rate. Compared with pure (PDDA/CdTe)n and (PDDA/PSS)n LBL film, Fe(CN)63? immobilized (PDDA/CdTe)n LBL film had good electron transfer ability. The immobility of Fe(CN)63? into the film was attributed to its interaction with Cd2+ on the surface of CdTe QDs. Fe(CN)63? also can interact with other metal ions, which would make Fe(CN)63? release from the film. The concentrations of metal ions will affect the CV response of Fe(CN)63? immobilized LBL film. It has provided a novel prototype of device or sensor for quantitative detection of metal ions.  相似文献   

6.
Highly stable Nafion‐covered hexacyanoferrate‐doped‐glutaraldehyde‐cross‐linked poly‐L ‐lysine (PLL‐GA‐Fe(CN)64?/Naf) film modified glassy carbon electrode (GCE), for the selective detection of dopamine (DA) in the presence of ascorbic acid (AA), was prepared by first ion‐exchanging Fe(CN)64? into PLL‐GA coating on GCE then sealing it with a Nafion outer layer. The Nafion over layer is crucial in preventing leaching of Fe(CN)64? ions from the inner layer. The first layer was acting as electrocatalyst for DA oxidation and the outer coating acted as discriminating layer for selective permeation of DA in the presence of interfering anionic species. More than 90% of the initial response was retained after coating with the Nafion protecting layer compared to a huge loss (>60%) without Nafion outer layer. 5% Nafion coating was identified as optimum thickness for the selective detection of DA in the presence of AA.  相似文献   

7.
Cobalt, despite an essential biological element, imposes threat to humans when exposed to high concentration or even to low concentration for long term which demands the development of highly sensitive and selective analytical methods for its trace analysis. In the present work, self‐assembly of p‐aminothiophenol (p‐ATP) on gold surface (Au?ATP SAM) was carried out and for the first time, applied as a platform for impedimetric and potentiometric sensing of Co2+. Au?ATP SAM was characterized using electrochemical techniques: cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), in the presence of two redox probes: [Fe(CN)6]3?/4? and [Ru(NH3)6]2+/3+ to evaluate associated passivating behaviour. Au?ATP SAM completely blocked [Fe(CN)6]3?/4? as compared to [Ru(NH3)6]2+/3+ which may be attributed to inner‐sphere and outer‐sphere ET mechanisms, respectively. Au?ATP SAM was found to exhibit excellent sensitivity towards Co2+ in a wider concentration range from 1.0×10?12 M to 1.0×10?5 M (r2=0.963) at pH 5.5 with a detection limit of 6.0×10?13 M and superior selectivity. Further, carbon paste electrode (CPE) was prepared by incorporating p‐ATP bound gold nanoparticles and explored for potentiometric sensing of Co2+ which exhibited Nernstian slope of 29.2±0.2 mV/dec in linear concentration range of 1.0×10?6 M–1.0×10?1 M (r2=0.971) with a detection limit of 8.0×10?7 M. The proposed sensors were successfully applied for estimation of Co2+ content in water samples.  相似文献   

8.
A new strategy of three‐electrode system fabrication in polymer‐based microfluidic systems is described here. Standard lithography, hot embossing and UV‐assisted thermal bonding were employed for fabrication and assembly of the microfluidic chip. For the electrode design the gold working (WE) and counter electrodes (CE) are placed inside a main channel through which the sample solution passes. A silver reference electrode (RE) is embedded in a small side channel containing KCl solution that is continuously pushed into the main channel. In the present work, the overall electrochemical set up and its microfabrication is described. Conditions including silver ion concentration, cyclic voltammetry (CV) settings, and the flow rate of KCl solution in the RE channel were optimized. The electrochemical performance of the three‐electrode system was evaluated by CV and also by amperometric oxidation of ferro hexacyanide ([Fe(CN)6]4?) and ruthenium bipyridyl ([Ru(bipy)3]2+) at 400 mV and 1200 mV, respectively. CV analysis using ferri/ferro hexacyanide showed a stable, quasi‐reversible redox reaction at the electrodes with 96 mV peak separation and an anodic/cathodic peak ratio of 1. Amperometric analysis of the electrochemical species resulted in linear correlation between analyte concentration and current response in the range of 0.5–15 µM for [Fe(CN)6]4?, and 0–1000 µM for [Ru(bipy)3]2+. Upon the given experimental conditions, the limit of detection was found to be 3.15 µM and 24.83 µM for [Fe(CN)6]4? and [Ru(bipy)3]2+, respectively. As a fully integrated three‐electrode system that is fabricated on polymer substrates, it has great applications in microfluidic‐based systems requiring stable electrochemical detection.  相似文献   

9.
This article aims to demonstrate an electrochemically stable and reliable gold electrode‐electrolyte system to develop an insect odorant receptor (Drosophila melanogaster Or35a) based bioelectronic nose. Cyclic voltammograms (CVs) and electrochemical impedance spectroscopy (EIS) of bare gold electrodes, after modification with the self‐assembled monolayer (SAM) of 6‐mercaptohexanoic acid (MHA) and after immobilization with Or35a integrated into the lipid bilayers of liposomes were conducted in the presence of four different redox probes. Potassium ferri/ferrocyanide [Fe(CN)6]3?/[Fe (CN)6]4? and hydroquinone (H2Q) redox probes revealed variable and irreversible signals at the time scale of our measurements, with atomic force microscopy (AFM) images and x‐ray photoelectron spectroscopy (XPS) results suggesting gold surface etching due to the presence of CN? ions in case of [Fe(CN)6]3?/[Fe (CN)6]4?. Although the hexaammineruthenium complex showed stable electrochemical behaviour at all stages of biosensor development, changes in CV and EIS readings after each surface modifications were insignificant. PBS buffer as a non‐Faradaic medium, was found to provide reliable systems for electrochemical probing of modified gold electrodes with Or35a/liposomes in aqueous media. Using this system, we have shown that this novel biosensor can detect its known odorant E2‐hexenal selectively compared to methyl salicylate down to femtomolar concentration.  相似文献   

10.
A novel amperometric immunosensor based on L ‐cysteine/nanosized Prussian blue bilayer films ({NPB/L ‐cys}2) and gold nanoparticles (nano‐Au) was fabricated for determination of human chorionic gonadotrophin (HCG). First, L ‐cys and NPB was self‐assembled by layer‐by‐layer (LBL) technology to form {NPB/L ‐cys}2 bilayer films on the gold electrode. Subsequently, nano‐Au layer was immobilized on the {NPB/L ‐cys}2 bilayer films by electrodepositing gold chloride tetrahydrate and then anti‐HCG was assembly on the nano‐Au layer. Finally hemoglobin (Hb) was employed to block sites against nonspecific binding. With the electrocatalytic ability of Hb and NPB for the reduction of H2O2, the current signal of the antigen‐antibody reaction was amplified and the enhanced sensitivity was achieved. In this study, the assembly process and performance of the immunosensor were characterized by cyclic voltammetry (CV) and the morphology was researched by scanning electron microscopy (SEM). The immunosensor performed a high sensitivity and a wide linear response to HCG in two ranges from 0.5 to 10 mIU/mL and from 10 to 200 mIU/mL with a relatively low detection limit of 0.2 mIU/mL at 3 times the background noise, as well as good stability and long‐term life.  相似文献   

11.
A simple layer‐by‐layer (LBL) assembly strategy was established for constructing a novel reagentless biosensor based on a nanocomposite of methylene blue multiwalled carbon nanotubes (MB‐MWNTs). A nanocomposite of MB‐MWNTs was obtained by direct premixing and possessed good dispersion in barbital‐HCl buffer. Through electrostatic interactions, the nanocomposite of MB‐MWNTs could alternately be assembled with horseradish peroxidase (HRP) on the Au electrode modified with precursor films. UV/Vis spectra and scanning electron microscopy (SEM) were applied to reveal the formation of the nanocomposite of MB‐MWNTs. The LBL assembly process was also verified by electrochemical impedance spectroscopy (EIS). The MB is a well‐established mediator and efficiently facilitated the electron shuttle between the HRP and the electrode, as demonstrated by the cyclic voltammetry (CV) measurements. The as‐prepared reagentless biosensor exhibited a fast response for the determination of hydrogen peroxide (H2O2) and reached 95% of the steady‐state current within 3 s. It was found that the linear response range of the reagentless biosensor for H2O2 was from 4.0 μM to 3.78 mM with a detection limit of 1.0 μM and a sensitivity of 22.5 μA mM−1. The biosensor exhibited a high reproducibility and stability.  相似文献   

12.
《Electroanalysis》2004,16(23):1992-1998
A carbon nanotubes‐based amperometric cholesterol biosensor has been fabricated through layer‐by‐layer (LBL) deposition of a cationic polyelectrolyte (PDDA, poly(diallyldimethylammonium chloride)) and cholesterol oxidase (ChOx) on multi‐walled carbon nanotubes (MWNTs)‐modified gold electrode, followed by electrochemical generation of a nonconducting poly(o‐phenylenediamine) (PPD) film as the protective coating. Electrochemical impedance measurements have shown that PDDA/ChOx multilayer film could be formed uniformly on MWNTs‐modified gold electrode. Due to the strong electrocatalytic properties of MWNTs toward H2O2 and the low permeability of PPD film for electroacitve species, such as ascorbic acid, uric acid and acetaminophen, the biosensor has shown high sensitivity and good anti‐interferent ability in the detection of cholesterol. The effect of the pH value of the detection solution on the response of the biosensor was also investigated. A linear range up to 6.0 mM has been observed for the biosensor with a detection limit of 0.2 mM. The apparent Michaelis‐Menten constant and the maximum response current density were calculated to be 7.17 mM and 7.32 μA cm?2, respectively.  相似文献   

13.
《Electroanalysis》2006,18(24):2451-2457
This paper describes a layer‐by‐layer (LBL) self‐assembly process of chitosan (CTS) and gold nanoparticles (Au) on the pretreated negatively charged glassy carbon (GC) electrode to fabricate electrochemistry immunosensor with a nontoxic biomimetic interface, which provided an environment similar to a native system and allowed more freedom in orientation for immobilization of carcinoembryonic antibody (anti‐CEA) to monitor carcinoembryonic antigen (CEA). UV‐vis spectroscope, atomic force microscopy (AFM), and cyclic voltammetric (CV) measurements were used to follow the multilayer film formation. The performance of the biominetic interface and factors influencing the assay system were investigated in detail. The differential pulse voltammetry (DPV) current response is used for the CEA concentration assay. The dynamic range was from 0.50 to 80.00 ng mL?1 with a detection limit of 0.27 ng mL?1 at 3σ. In addition, the experiment results indicate that immobilization described in this proposed method exhibits a good sensitivity, selectivity, and stability.  相似文献   

14.
Electrochemical oxidation of a phospholipid, phosphatidylcholine (PC), was accomplished at a 4‐aminothiophenol (ATP)‐modified gold electrode coated with a layer‐by‐layer assembly of an electrochemical catalyst (dirhodium phosphomolybdic acid), a trapping agent for PC (a cyclophane, CP, derivative, 1,4‐xylylene‐1,4‐phenylene‐diacetate), and a spacer (generation‐4 polyamidoamine dendrimer, PAMAM). The layer‐by‐layer assembly process and the trapping of PC was verified by quartz crystal microbalance measurements; Au|ATP|CP|PAMAM|CP trapped (1.5±0.4)×10?9 mol cm?2 of PC. The electrocatalytic oxidation of PC yielded a current that varied linearly with concentration over the range 1–50 μM; the R2 value was 0.996.  相似文献   

15.
A DNA biosensor for the detection of specific oligonucleotide sequences of Avian Influenza Virus type H5N1 has been proposed. The NH2‐ssDNA probe was deposited onto a gold electrode surface to form an amide bond between the carboxyl group of thioacid and the amino group from ssDNA probe. The signals generated as a result of hybridization were registered in square wave voltammetry and electrochemical impedance spectroscopy in the presence of [Fe(CN)6]3?/4? as a redox marker. The genosensor is capable to determine 20‐mer and 180‐bp (PCR products) oligonucleotides complementary sequences with detection limit in the fM range. The genosensor displays good selectivity and sensitivity. The 20‐mer as well as 180‐bp oligonucleotides without a complementary sequence generate very low signal.  相似文献   

16.
A highly effective strategy for quantification of plasmid which was a special dsDNA based on bisPNA by electrochemical impedance spectroscopy was presented in this work. Firstly, through Au?S bond, thiol‐terminated bisPNA probes were immobilized onto the gold electrode surface. Then bisPNA probes directly hybridized with target plasmid DNA pBR322 based on the PNA.DNA‐PNA invasion triplex without denaturation. In the presence of redox electroactive ions [Fe(CN)6]3?/4? as hybridization indicator, the charge transfer resistance (Rct) was produced, and Rct was measured via electrochemical impedance spectroscopy. Under optimal conditions, this strategy showed a good linear relationship between the ΔRct which was the difference of Rct obtained before and after bisPNA hybridized with plasmid pBR322, and logarithm of the concentration of plasmid pBR322 within the range from 1 nM to 100 nM (R2=0.993), with a limit of detection (LOD) of 0.1 nM. Furthermore, this bisPNA‐assisted biosensor showed good stability and satisfactory analytical reliability. In addition, this novel bisPNA‐assisted biosensor also exhibited excellent analytical results in human serum.  相似文献   

17.
A DNA‐based biosensor was reported for detection of silver ions (Ag+) by electrochemical impedance spectroscopy (EIS) with [Fe(CN)6]4?/3? as redox probe and hybridization chain reaction (HCR) induced hemin/G‐quadruplex nanowire as enhanced label. In the present of target Ag+, Ag+ interacted with cytosine‐cytosine (C? C) mismatch to form the stable C? Ag+? C complex with the aim of immobilizing the primer DNA on electrode, which thus triggered the HCR to form inert hemin/G‐quadruplex nanowire with an amplified EIS signal. As a result, the DNA biosensor showed a high sensitivity with the concentration range spanning from 0.1 nM to 100 µM and a detection limit of 0.05 nM.  相似文献   

18.
We report a simple and effective strategy for fabrication of the nanocomposite containing chitosan (CS) and multiwall carbon nanotube (MWNT) coated on a glassy carbon electrode (GCE). The characterization of the modified electrode (CS‐MWNT/GC) was carried out using scanning electron microscopy (SEM) and UV–vis absorption spectroscopy. The electrochemical behavior of CS‐MWNT/GC electrode was investigated and compared with the electrochemical behavior of chitosan modified GC (CS/GC), multiwalled carbon nanotube modified GC (MWNT/GC) and unmodified GC using cyclic voltammetry (CV) and electron impedance spectroscopy (EIS). The chitosan films are electrochemically inactive; similar background charging currents are observed at bare GC. The chitosan films are permeable to anionic Fe(CN)63?/4? (FC) redox couple. Electrochemical parameters, including apparent diffusion coefficient for the Fe(CN)63?/4? redox probe at FC/CS‐MWNT/GC electrode is comparable to values reported for cast chitosan films. This modified electrode also showed electrocatalytic effect for the simultaneous determination of D‐penicillamine (D‐PA) and tryptophan (Trp). The detection limit of 0.9 μM and 4.0 μM for D‐PA and Trp, respectively, makes this nanocomposite very suitable for determination of them with good sensitivity.  相似文献   

19.
A highly sensitive impedimetric immunosensor based on a gold nanoparticles/multiwall carbon nanotube-ionic liquid electrode (AuNPs/MW-CILE) was developed for the determination of human epidermal growth factor receptor 2 (HER2). Gold nanoparticles were used to enhance the extent of immobilization and to retain the immunoactivity of the antibody Herceptin on the electrode. Cyclic voltammetry and electrochemical impedance spectroscopy were employed for characterization of various layers coated onto the AuNPs/MW-CILE. The impedance measurements at different steps were based on the charge transfer kinetics of the [Fe(CN)6]3−/4− redox pair. The immobilization of antibody and the corresponding antigen–antibody interaction at the electrode surface altered the interfacial electron transfer. The interactions of antibody with various concentrations of antigen were also monitored via the change of impedance response. The results showed that the charge transfer resistance increases linearly with increasing concentrations of HER2 antigen. The linear range and limit of detection were found as 10–110 ng mL−1 and 7.4 ng mL−1, respectively. The sensitivity and specificity of the immunosensor were validated. The results showed that the prepared immunosensor is a useful tool for screening of trace amounts of HER2 in serum samples of breast cancer patients.  相似文献   

20.
《Electroanalysis》2018,30(9):2160-2166
The present study focuses on designing and fabricating an electrochemical aptasensor for the label free detection of bisphenol A (BPA) using gold nanoparticles (Au NPs) immobilized on functional cupper magnetic nanoparticles (CuFe2O4‐SH) and multiwall carbon nanotubes (MWCNTs) modified with aptamer and 6‐mercapto‐1‐hexanol (MCH). A number of analysis techniques were used to characterize the nanocomposite, including Fourier transform infrared spectroscopy, field emission scanning electron microscopy, transmission electron microscopy, vibrating sample magnetometer, elemental mapping analysis and energy dispersive x‐ray diffraction. The results of the analyses revealed that the fabricated aptasensor had an acceptable linearity index (0.05‐9 nM) with an ultralow detection limit (25.2 pM) when used to determine BPA. Electrochemical experiments were conducted using a [Fe(CN)6]3−/[Fe(CN)6]4− redox system. The results of the electrochemical tests indicated that the existence of Au NPs along with magnetic nanoparticles and MWCNTs in nanocomposite led to a synergistic augmentation on the surface of the modified electrode, thus facilitating the efficient sensing of BPA. This method is highly selective, sensitive and environmentally friendly. Moreover, proposed aptasensor has valuable potential applications in medical diagnostics and food industries where a fast and reliable detection of BPA is of paramount importance for the health of the public.  相似文献   