首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Putrescine oxidase (PUO) from Micrococcus rubens has been characterized, as a biocatalytic component for the development of electrochemical biosensors for the determination of putrescine. PUO was immobilized by cross‐linking on screen‐printed carbon electrodes (SPCEs) containing tetrathiafulvalene (TTF) as mediator (TTF/SPCEs). Isothermal titration calorimetry was used for investigation of kinetic properties of immobilized PUO. These PUO/TTF/SPCEs showed a linear response range from 10 a 74 µM, a capability of detection of 10.1±0.6 µM (n=4, α=β=0.05) and a precision of 6.7 %. Octopus and zucchini samples have been analysed using HPLC as a reference technique.  相似文献   

2.
An improved amino oxidase enzyme electrode has been constructed and applied to the determination of the amount of polyamines present in real samples. The electrode is based on the amperometric detection of H2O2 produced in the enzymatic oxidation of polyamines by amino oxidase. Amino oxidase from soybean seedlings, characterized by an extremely high activity for cadaverine and putrescine, was used. The enzyme was immobilized in an agarose matrix in the presence of glutaraldehyde and bovine serum albumin on the surface of a Pt electrode. Cadaverine, in concentrations between 0.5 and 500 μM, can be quantitatively determined by use of the amino oxidase electrode, the linear calibration range being 0.5–10 μM. The lower detection limit was 0.2 μM and the response time was 15 to 60 s. Putrescine showed similar behaviour. The maximum current response for cadaverine was 5.1 μA/cm2, with an apparent Michaelis-Menten constant (Km′) of 0.175 mM. The sensor response was stable for more than 32 hours of continuous operation at room temperature and, in the presence of fish or meat homogenates, no change in the signal-to-noise ratio was observed. The long-term stability, pH and temperature response of the biosensor has also been studied.  相似文献   

3.
In this study, high‐performance liquid chromatography coupled with tandem mass spectrometry was used to assess the results of bioactive compound screening from natural products using immobilized enzyme magnetic beads. We compared three commercial magnetic beads with modified amino, carboxy, and N‐hydroxysuccinimide groups, respectively. Amino magnetic beads performed best for immobilization and were selected for further experiments. Xanthine oxidase was immobilized on amino magnetic beads and applied to screen potential inhibitors in fresh Zingiber officinale Roscoe, extracts of Scutellaria baicalensis Georgi, and Pueraria lobata Ohwi. In total, 12 potential xanthine oxidase ligands were identified from fresh Zingiber root and Scutellaria root extracts, of which eight were characterized and the concentration required for 50% inhibition was determined. Preliminary structure–function relationships were discussed based on these results. A convenient and effective method was therefore developed for the identification of active compounds from complex natural product mixtures.  相似文献   

4.
We describe a simple, rapid, selective and sensitive HPLC method coupled with fluorescence detection for simultaneous determination of 10 kinds of biogenic amines (BAs: tryptamine, 2‐phenethylamine, putrescine, cadaverine, histamine, 5‐hydroxytryptamine, tyramine, spermidine, dopamine and spermine). BAs and IS were derivated with dansyl chloride. Fluorescence detection (λex/λem = 340/510 nm) was used. A satisfactory result for method validation was obtained. The assay was shown to be linear over the ranges 0.005–1.0 μg/mL for tryptamine, 2‐phenethylamine and spermidine, 0.025–1.0 μg/mL for putrescine, 0.001–1.0 μg/mL for cadaverine, 0.25–20 μg/mL for histamine, 0.25–10 μg/mL for 5–hydroxytryptamine and dopamine, and 0.01–1.0 μg/mL for tyramine and spermine. The limits of detection and the limits of quantification were 0.3–75.0 ng/mL and 1.0–250.0 ng/mL, respectively. Relative standard deviations were ≤5.14% for intra‐day and ≤6.58% for inter‐day precision. The recoveries of BAs ranged from 79.11 to 114.26% after spiking standard solutions of BAs into a sample at three levels. Seven kinds of BAs were found in rat plasma, and the mean values of tryptamine, 2‐phenethylamine, putrescine, cadaverine, histamine, spermidine and spermine determined were 52.72 ± 7.34, 11.45 ± 1.56, 162.56 ± 6.26, 312.75 ± 18.11, 1306.50 ± 116.16, 273.89 ± 26.41 and 41.51 ± 2.07 ng/mL, respectively.  相似文献   

5.
《Electroanalysis》2006,18(8):748-756
Amperometric biosensors based on the corresponding oxidase enzyme with poly(neutral red) redox mediator have been developed for the determination of glucose and pyruvate. The enzymes have been immobilized on top of poly(neutral red) modified carbon film electrodes with glutaraldehyde as the cross‐linking agent. The biosensors were characterized by cyclic voltammetry and by electrochemical impedance spectroscopy. The glucose biosensor exhibited a linear response in the range 90 μM to 1.8 mM with a detection limit of 22 μM and the pyruvate biosensor in the range 90 to 600 μM with a detection limit of 34 μM. The relative standard deviations were found to be 2.1% (n=3) and 2.8% (n=4) respectively. The interference effects of various compounds were also studied. The glucose content of several types of wine and the amount of pyruvate in onion and garlic were determined and the results were compared with those obtained by standard spectrophotometric methods.  相似文献   

6.
Direct electrochemistry of cholesterol oxidase (ChOx) immobilized on the conductive poly‐3′,4′‐diamine‐2,2′,5′,2″‐terthiophene (PDATT) was achieved and used to create a cholesterol biosensor. A well‐defined redox peak was observed, corresponding to the direct electron transfer of the FAD/FADH2 of ChOx, and the rate constant (ks) was determined to be 0.75 s?1. Glutathione (GSH) covalently bonded with PDATT was used as a matrix for conjugating AuNPs, ChOx, and MP, simultaneously. MP co‐immobilized with ChOx on the AuNPs‐GSH/PDATT exhibited an excellent amperometric response to cholesterol. The dynamic range was from 10 to 130 μM with a detection limit of 0.3±0.04 μM.  相似文献   

7.
A novel method for preparation of hydrogen peroxide biosensor was presented based on immobilization of hemoglobin (Hb) on carbon‐coated iron nanoparticles (CIN). CIN was firstly dispersed in a chitosan solution and cast onto a glassy carbon electrode to form a CIN/chitosan composite film modified electrode. Hb was then immobilized onto the composite film with the cross‐linking of glutaraldehyde. The immobilized Hb displayed a pair of stable and quasireversible redox peaks and excellent electrocatalytic reduction of hydrogen peroxide (H2O2), which leading to an unmediated biosensor for H2O2. The electrocatalytic response exhibited a linear dependence on H2O2 concentration in a wide range from 3.1 μM to 4.0 mM with a detection limit of 1.2 μM (S/N=3). The designed biosensor exhibited acceptable stability, long‐term life and good reproducibility.  相似文献   

8.
《Electroanalysis》2005,17(23):2114-2120
The biopolymer chitosan (CHIT) was chemically modified with glutaric dialdehyde (GDI) and used for the covalent immobilization of enzyme glutamate oxidase (GmOx). The relationships between the loaded, retained, and active units of GmOx in the CHIT‐GDI‐GmOx gels were determined by electrochemical assays. The latter indicated that on average ca. 95% of the GmOx was retained in the CHIT‐GDI matrix that was loaded with 0.10–3.0 units of the enzyme. The maximum activity of the GmOx immobilized in the gels corresponded to ca. 5% of the activity of the free enzyme. Platinum electrodes coated with CHIT‐GDI‐GmOx gels (films) were used as amperometric biosensors for glutamate. Such biosensors displayed good operational and long‐term stability (at least 11 h and 100 days, respectively) in conjunction with low detection limit of 0.10 μM glutamate (S/N=3), linear range up to 0.5 mM (R2=0.991), sensitivity of 100 mA M?1 cm?2, and short response time (t90%=2 s). This demonstrated an efficient signal transduction in the Pt/CHIT‐GDI‐GmOx+glutamate system. The CHIT‐GDI‐GmOx gels constitute a new biosensing element for the development of glutamate biosensors.  相似文献   

9.
A comparison of the analytical characteristics of two tyramine biosensors, based on graphene oxide (GRO) and polyvinylferrocene (PVF) modified screen‐printed carbon electrodes (SPCE), is reported. Diamine oxidase (DAOx) or monoamine oxidase (MAOx) was immobilized onto the PVF/GRO modified SPCE to fabricate the biosensors. Surface characteristics and electrochemical behaviour of the modified SPCEs were investigated by atomic force microscopy (AFM), scanning electron microscopy (SEM), energy dispersive X‐ray spectroscopy (EDX) and cyclic voltammetry (CV). Electrode surface composition and experimental variables such as pH and working potential were optimized in order to ensure a high performance. Under optimum experimental conditions, both DAOx/PVF/GRO/SPCE and MAOx/PVF/GRO/SPCE biosensors exhibited wide linear dynamic ranges for tyramine from 9.9×10?7 to 1.2×10?4 M and from 9.9×10?7 to 1.1×10?4 M, respectively. MAOx/PVF/GRO/SPCE biosensor showed higher sensitivity (11.98 μA mM?1) for tyramine determination than the DAOx/PVF/GRO/SPCE biosensor (7.99 μA mM?1). The substrate specifity of the biosensors to other biogenic amines namely histamine, putrescine, spermine, spermidine, tryptamine, β‐phenylethylamine and cadaverine was also investigated. The developed biosensors were successfully used for tyramine determination in cheese sample.  相似文献   

10.
Putrescine oxidase ([PO]; E.C. 1.4.3.4), which catalyzes the oxidative deamination of putrescine into γ-aminobutyraldehyde, has been partially purified from Candida guilliermondii. Among the substrates tested, putrescine has the highest reaction rate, followed by spermidine and cadaverine. The K IN values for putrescine, spermidine, and cadaverine were 20, 200, and 1.1 mM, respectively. The optimum pH and the temperature for PO were 8.0 and 37°C, respectively. Growth of Candida species on putrescine as the solenitrogen source induced the synthesis of PO that converts putrescine into Δ1-pyrroline and γ-aminobutyric acid. These two products were detected and identified from the culture medium. The enzyme was not activated by divalent cations. Among the species of Candida tested, the highest enzyme activity was found in cell-free extracts of C. guilliermondii. The pathway of putrescine degradation was identified by substrate analysis to be along the nonacetylated pathway in C. guilliermondii.  相似文献   

11.
A quantitative analysis of polyamines in lung cancer patient fingernails by the combination of 4‐(N,N‐dimethylaminosulfonyl)‐7‐fluoro‐2,1,3‐benzoxadiazole derivatives and liquid chromatography–electrospray ionization tandem mass spectrometry is described. The reaction of the reagent with eight kinds of polyamines, that is, N1‐acetylputrescine (N1‐actPUT), N8‐acetylspermidine, N1‐acetylspermine, 1,3‐diaminopropane, putrescine (PUT), cadaverine, spermidine and spermine (SPM) effectively occurs at 60 °C for 30 min. The detection limits (signal‐to‐noise ratio 5) were 5–100 fmol. A good linearity was achieved from the calibration curves, which was obtained by plotting the peak area ratios of the analytes relative to the internal standard (IS), that is, 1,6‐diaminohexane, vs the injected amounts of polyamines (r2 > 0.996), and the intra‐day and inter‐day assay precisions were <9.84%. Furthermore, the recoveries (%) of the polyamines spiked in the human fingernails were 89.14–110.64. The present method was applied to human fingernail samples from 17 lung cancer patients and 39 healthy volunteers. The polyamine concentration was different based on the gender, that is, the N1‐actPUT and PUT contents were 3.10 times and 2.56 times higher in healthy men than in women, respectively. Additionally, in the lung cancer patient group, as compared with the healthy volunteers, the concentrations of SPM had a statistically significant (p < 0.05) correlation. Therefore, because the proposed method provides a good mass accuracy and the trace detection of the polyamines in human fingernails, this analytical technique could be a noninvasive technique to assist in the diagnosis and assessment of disease activity in lung cancer patients. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
The direct electrochemistry of glucose oxidase (GOD) immobilized on the designed titanium carbide‐Au nanoparticles‐fullerene C60 composite film modified glassy carbon electrode (TiC‐AuNPs‐C60/GCE) and its biosensing for glucose were investigated. UV‐visible and Fourier‐transform infrared spectra of the resulting GOD/TiC‐AuNPs‐C60 composite film suggested that the immobilized GOD retained its original structure. The direct electron transfer behaviors of immobilized GOD at the GOD/TiC‐AuNPs‐C60/GCE were investigated by cyclic voltammetry in which a pair of well‐defined, quasi‐reversible redox peaks with the formal potential (E0′) of ‐0.484 V (vs. SCE) in phosphate buffer solution (0.05 M, pH 7.0) at the scan rate of 100 mV·s?1 were obtained. The proposed GOD modified electrode exhibited an excellent electrocatalytic activity to the reduction of glucose, and the currents of glucose reduction peak were linearly related to glucose concentration in a wider linearity range from 5.0 × 10?6 to 1.6 × 10?4 M with a correlation coefficient of 0.9965 and a detection limit of 2.0 × 10?6 M (S/N = 3). The sensitivity and the apparent Michaelis‐Menten constant (KMapp) were determined to be 149.3 μA·mM?1·cm?2 and 6.2 × 10?5 M, respectively. Thus, the protocol will have potential application in studying the electron transfer of enzyme and the design of novel electrochemical biosensors.  相似文献   

13.
Copper containing nitrite reductase (Cu‐NiR) and viologen‐modified sulfonated polyaminopropylsiloxane (PAPS‐SO3H‐V) were co‐immobilized on glassy carbon electrode (GCE) by hydrophilic polyurethane (HPU) drop‐coating, and the electrode was tested as a reagentless electrochemical biosensor for nitrite detection. The newly synthesized PAPS‐SO3H‐V as an electron transfer (ET) mediator between electrode and NiR was effective, and could be effectively immobilized in HPU membrane. The NiR and PAPS‐SO3H‐V co‐immobilized GCE used as a nitrite biosensor showed the following performance factors: sensitivity=12.0 nA μM?1, limit of detection (LOD)=60 nM (S/N=3), linear response range=0–18 μM (r2=0.996) and response time (t90%)=60 s, respectively. Lineweaver–Burk plot shows that apparent Michaelis–Menten constant (K is 101 μM. Storage stability of the sensor is 51 days (80% of initial activity) in condition of storing in ambient air at room temperature. The sensor showed a relative standard deviation (RSD) of 3.2% (n=5) even in condition of injection of 1 μM nitrite. Interference study showed that common anions in water sample such as chlorate, chloride, sulfate and sulfite do not interfere with the nitrite detection. However, nitrate interfered with a relative sensitivity of 80% due to inherent character of the enzyme used.  相似文献   

14.
《Electroanalysis》2004,16(9):730-735
Electrooxidation of thionine on screen‐printed carbon electrode gives rise to the modification of the surface with amino groups for the covalent immobilization of enzymes such as horseradish peroxidase (HRP). The biosensor was constructed using multilayer enzymes which covalently immobilized onto the surface of amino groups modified screen‐printed carbon electrode using glutaraldehyde as a bifunctional reagent. The multilayer assemble of HRP has been characterized with the cyclic voltammetry and the faradaic impedance spectroscopy. The H2O2 biosensor exhibited a fast response (2 s) and low detection limit (0.5 μM).  相似文献   

15.
We have developed screen–printed carbon electrodes for the determination of tyramine (Tyr) via plasma amine oxidase. The enzyme was immobilized on the carbon working electrode by cross–linking it with bovine serum albumin using glutaraldehyde. The employment of the mediator hydroxymethylferrocene lowers the working potential to +260 mV (vs. a screen–printed Ag/AgCl reference electrode). The effects of pH, potential and mediator concentration were optimized and resulted in reproducibility and repeatability values of 8.6 % and 8.7 %, respectively. Response is linear in the range from 2 to 164 μM, and the limit of detection is 2.0?±?0.18 μM. The effects of potentially interfering biogenic amines such as putrescine, cadaverine, histamine, spermine, spermidine and tryptamine were also evaluated. The biosensor was successfully applied to the determination of Tyr in cheese.
Figure
Amperometric determination of tyramine using a biosensor based on the immobilization of polyamine oxidase (PAO) enzyme on a disposable screen-printed carbon electrode.  相似文献   

16.
《Electroanalysis》2018,30(8):1642-1652
A newly developed amperometric glucose biosensor based on graphite rod (GR) working electrode modified with biocomposite consisting of poly (pyrrole‐2‐carboxylic acid) (PCPy) particles and enzyme glucose oxidase (GOx) was investigated. The PCPy particles were synthesized by chemical oxidative polymerization technique using H2O2 as initiator of polymerization reaction and modified covalently with the GOx (PCPy‐GOx) after activation of carboxyl groups located on the particles surface with a mixture of N‐(3‐dimethylaminopropyl)‐N′‐ethylcarbodiimide hydrochloride (EDC) and N‐hydroxysuccinimide (NHS). Then the PCPy‐GOx biocomposite was dispersed in a buffer solution containing a certain amount of bovine serum albumin (BSA). The resulting biocomposite suspension was adsorbed the on GR electrode surface with subsequent solvent airing and chemical cross‐linking of the proteins with glutaraldehyde vapour (GR/PCPy‐GOx). It was determined that the current response of the GR/PCPy‐GOx electrodes to glucose measured at +300 mV vs Cl reference electrode was influenced by the duration of the PCPy particles synthesis, pH of the GOx solution used for the PCPy particles modification and the amount of immobilized PCPy‐GOx biocomposite. An optimal pH of buffer solution for operation of the biosensor was found to be 8.0. Detection limit was determined as 0.039 mmol L−1 according signal to noise ratio (S/N: 3). The proposed glucose biosensor was tested in human serum samples.  相似文献   

17.
A novel enzyme immobilization technique based on thionine‐bovine serum albumin conjugate (Th‐BSA) and gold colloidal nanoparticles (nano‐Au) was developed. Thionine was covalently bound onto the BSA film with glutaraldehyde(GA) as cross‐linker to achieve Th‐BSA conjugate. The free amino groups of thionine were then used to attach nano‐Au for the immobilization of horseradish peroxidase (HRP). Such nano‐Au/Th‐BSA matrix shows a favorable microenvironment for retaining the native activity of the immobilized HRP and thionine immobilized in this way can effectively shuttle electrons between the electrode and the enzyme. The proposed biosensor displays excellent catalytic activity and rapid response for H2O2. The linear range for the determination of H2O2 is from 4.9×10?7 to 1.6×10?3 M with a detection limit of 2.1×10?7 M at 3σ and a Michaelies‐Menten constant K value of 0.023 mM.  相似文献   

18.
A selective and sensitive method is presented for biogenic amines (BA) determination. The novelty consists in coupling a highly selective electrochemical biosensor to a weak acid cation-exchange column for online detection of amines. A bienzyme design, based on a recently isolated amine oxidase from grass pea and commercial horseradish peroxidase, was used for the biosensor construction. The enzymes were co-immobilized on the surface of a graphite electrode together with the electrochemical mediator (Os-redox polymer). The electrochemical detection was performed at a low applied potential (?50 mV vs. Ag/AgCl, KCl0.1 M), where biases from interferences are minimal. The separation and determination of six BA, with relevance in food analysis (tyramine, putrescine, cadaverine, histamine, agmatine and spermidine), were investigated. Irrespective of the BA nature, the amine oxidase-based biosensor showed a linear response up to 5 mM, and its sensitivity decreases in the following order: cadaverine, putrescine, spermidine, agmatine, histamine and tyramine. The approach was used to estimate the BA content in fish samples, after their extraction with methanesulfonic acid.  相似文献   

19.
We have developed screen-printed carbon electrodes for the determination of putrescine (Put) via the enzyme monoamine oxidase that was immobilized on the surface of the electrode by cross-linking it with bovine serum albumin using glutaraldehyde. A mixture of 5 % of tetrathiofulvalene (TTF) and carbon ink was used for the fabrication of the screen-printed working electrode. Put was amperometrically detected by measurement of the current due to the oxidation of the mediator TTF. The use of TTF lowers the working potential to +250 mV (vs. a screen-printed Ag/AgCl reference electrode). Response is linear in the range from 16 to 101 μM, and the detection limit is 17.2?±?4.6 μM, with a reproducibility of 9.6 % (n?=?4) in terms of relative standard deviation. The effects of potentially interfering biogenic amines such as cadaverine, histamine, spermine, spermidine and tryptamine were also evaluated. The biosensor was successfully applied to the determination of Put in zucchini and anchovies.
Figure
Amperometric determination of putrescine using a biosensor based on the immobilization of monoamine oxidase (MAO) enzyme on a disposable screen-printed carbon electrode modified with tetrathiofulvalene (TTF)  相似文献   

20.
A sensitive capillary electrophoresis (CE) method with chemiluminescence (CL) detection was developed for the determination of homocysteine (HCys) in human plasma. In this work, N‐(4‐aminobutyl)‐N‐ethylisoluminol was used as tagging reagent to label the analyte for achieving high assay sensitivity. N‐(4‐Aminobutyl)‐N‐ethylisoluminol‐tagged HCys after CE separation reacted with hydrogen peroxide in the presence of horseradish peroxidase, producing CL emission. Experimental conditions for labeling analyte, CE separation, and CL detection were studied. The CL intensity was proportional to the concentration of HCys in the range of 2.5×10?8 to 5.0×10?6 M. Detection limit (S/N=3) was 7.6×10?9 M. Human plasma samples from healthy donors were analyzed by the presented method. HCys levels were found to be in the range of 9.50–15.3 μM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号