共查询到20条相似文献,搜索用时 15 毫秒
1.
A dichromate‐selective PVC‐membrane electrode based on Quinaldine Red (an acridinium derivative) is described. The electrode exhibits rapid (< 30 s) and linear response to the activity of Cr(VI) anions in the range of 5.2 × 10?6 ?1.0 × 10?1 M dichromate with the limit of detection 2.5 × 10?6 Mof Cr2O72?. The sensor is used as an indicator electrode in potentiometric determination of Cr(VI) anions and is also suitable for end‐point indication in the titrations of proper metal ions with dichromate under laboratory conditions. The proposed electrode has been applied to the direct potentiometric determination of Cr(VI) anions in water samples with satisfactory results. 相似文献
2.
Speciation of Cr(III) and Cr(VI) can be attained by flow injection analysis with amperometric detection. Cr(VI) is reduced in an acidic medium to Cr(III) with a glassy carbon electrode at —0.1 V vs. Ag/AgCl and the current is recorded. Cr(III) is oxidised on-line to Cr(VI) with alkaline hydrogen peroxide solution. From the difference of the total chromium and Cr(VI), the amount of Cr(III) was obtained. A linear calibration curve for Cr(VI) was obtained for the concentration ranges 0.01-5.0ppm of Cr(VI) and we have calculated the limit of determination to be about 0.5ppb. We have studied the degree of reproducibility obtained using the solid electrodes under various conditions. The influence of flow rate, coil length, interfenences and the extent of reaction were studied. 相似文献
3.
A novel Cr(III) ion‐selective electrode is constructed by incorporating a new aryl amide bifunctional bridging ligand, 2,2′‐bis{[(2″‐benzylaminoformyl)phenxoyl]methyl}‐diethylether (BBPMD) as a neutral carrier into the PVC matrix. The proposed electrode, with optimum membrane composition, exhibits an excellent near‐Nernstian response for Cr3+ ion ranging from 2.8 × 10?6 to 1.0 × 10?1 mol/L with a detection limit of 8.6 × 10?7 mol/L and a slope of 19.5 ± 0.2 mV/dec in pH 3.0 nitrate buffer solution at 25 °C. It has an appropriate response time, suitable reproducibility, and good selectivity towards Cr3+ ion. The operational pH range of the proposed electrode is 2.5–6.5. The response mechanism was discussed in view of UV‐vis spectroscopy and the A. C. impedance technique. The excellent analytical features of the proposed electrode could lead to its successful application as an indicator electrode in potentiometric titration of Cr3+ ion and in the direct determination of Cr3+ ion in tea leaves and coffee samples. 相似文献
4.
Morteza Akhond Mohammad Bagher Najafi Hashem Sharghi Javad Tashkhourian Hossein Naiemi 《中国化学会会志》2007,54(2):331-337
A PVC membrane electrode for copper(II) ion based on a recently synthesized Schiff base as a suitable ion carrier was constructed. The electrode exhibits a Nernstian slope of 28.3 ± 0.6 mV per decade of Cu2+ over a wide concentration range of 7.0 × 10?6‐2.6 × 10?2 M with a detection limit of 5.0 × 10?6M in the pH range of 4.2–5.8. The response time is about 10s and it can be used for at least 1 month without any considerable divergence in potential. It was successfully applied as an indicator electrode in the potentiometric titration of copper ions. 相似文献
5.
《Electroanalysis》2006,18(23):2381-2384
A simple and highly selective and sensitive catalytic adsorptive stripping voltammetric procedure for determination of traces of Cr(VI) in the presence of a large excess of Cr(III) in environmental water samples is reported. To obtain a low detection limit the voltammetric procedure of chromium determination in the presence of DTPA and nitrate was exploited. For elimination of interference of Cr(III) ethylenediaminedisuccinic acid was used as a masking agent. At optimized conditions the calibration graph is linear from 2×10?10 to 2×10?8 mol L?1 for accumulation time of 30 s. The validation of the procedure was performed by comparison of the results of analysis of river water samples with those obtained using other accepted voltammetric procedure. 相似文献
6.
A highly selective PVC membrane electrode for Al3+ based on salicylaldehyde salicyloyl hydrazone as a neutral carrier has been prepared and studied. The sensor exhibits a good response for Al3+ over a linear range of 9.0 × 10‐6 to 1.0 × 10‐1 mol/L, with a Nernstian slope of 20.0 ± 0.2 mV/decade and detection limit of 7.0 × 10‐6 mol/L. Selectivity coefficients determined by the method of separate solution indicate high selectivity for Al3+. The response mechanism was discussed in view of UV‐Vis spectroscopy technique and the A.C. impedance technique. It was used as an indicator electrode in potentiometric titration of Al3+ with EDTA and in the determination of Al3+ in real samples. The electrode has a relatively fast response time, long life time and satisfactory stability. 相似文献
7.
Koteswara Rao Bandi Ashok Kumar Singh Kamaluddin A. K. Jain V. K. Gupta 《Electroanalysis》2011,23(12):2839-2850
Poly(vinyl chloride)‐based membranes of salen ligands, 2‐((E)‐((1R,2S)‐2‐((E)‐5‐tert‐butyl‐2‐hydroxybenzylideneamino)cyclohexylimino)methyl)‐4‐tert‐butyl phenol (S1) and 2‐((E)‐((1R,2S)‐2‐((E)‐3,5‐di‐tert‐butyl‐2‐hydroxybenzylideneamino)cyclohexylimino)methyl)‐4,6‐di‐tert‐butylphenol (S2) were fabricated and explored as cobalt(II) selective electrodes. The performance of the polymeric membrane electrode (PME) and coated graphite electrode (CGE) were compared and it was observed that CGE showed a wide working concentration range of 1.1×10?8 to 1.0×10?1 mol L?1 with a limit of detection of 7.0×10?9 mol L?1 exhibiting the Nernstian slope 29.6 mV/decade of activity in the pH range 3.0–9.0. It was used for the determination of cobalt(II) ions in water, soil, beer, pharmaceutical samples and medicinal plants and would be used as an indicator electrode in potentiometric titration with EDTA. 相似文献
8.
《Electroanalysis》2006,18(12):1186-1192
A PVC membrane electrode using [Bzo2Me2Ph2(16)hexaeneN4] ( I ) as ionophore, oleic acid as lipophilic additive and o‐nitrophenyloctyl ether as plasticizer has been investigated as Zn(II)‐selective electrode. The membrane incorporating 34.9% (w/w) PVC, 2.3% I , 4.7% OA and 58.1% o‐NPOE gave linear response over the concentration range 2.82×10?6?1.0×10?1 M with a Nernstian slope of 28.5±0.2 mV/decade of concentration with a detection limit of 2.24×10?6 M (0.146 ppm) and showed a response time of less than 10 s and could be used in pH range 2.5–8.5. High selectivity was obtained over a wide variety of metal ions. The proposed electrode was successfully used as an indicator electrode in potentiometric titration of zinc ions with EDTA and for determination of zinc in real samples. 相似文献
9.
Bastien Néel Majid Ghahraman Asfhar Gastón A. Crespo Marcin Pawlak Denis Dorokhin Eric Bakker 《Electroanalysis》2014,26(3):473-480
A series of polymeric nitrite‐selective electrodes containing a new lipophilic ionophore Co(II) tert‐butyl‐salophen is reported. The stability of Co(II) ionophores within a PVC‐based membrane was investigated by leaching experiments. Different membrane compositions were explored in order to reach the lowest possible limit of detection for a PVC‐based nitrite selective polymeric membrane electrode containing this ionophore. The optimal electrode showed a limit of detection of 2×10?6 M and exhibited four orders of magnitude of discrimination over nitrate, chloride and bromide. The electrodes were evaluated in undiluted human urine and attest to the robustness of the ionophore. 相似文献
10.
《Electroanalysis》2004,16(12):973-978
An ion selective electrode based on the dinuclear complex formed by two zinc(II) ions and two molecules of the bis‐N,O‐bidentate Schiff base 2,2′‐[methylenebis(4,1‐phenylenenitrilomethylidyne)]bisphenol exhibits thiocyanate selectivity with a good discrimination of nitrite, nitrate, and azide. The selectivities of electrode membranes with various compositions indicate that this potentiometric selectivity is based on the formation of a 1 : 1 complex between the thiocyanate anion and the dinuclear ionophore. The 2 : 1 ratio of thiocyanate ions and the dinuclear ionophore that results from higher ratios of cationic sites and ionophore worsens the selectivity, suggesting that binding of a thiocyanate to both zinc(II) centers of the dinuclear ionophore is not favorable. Interestingly, the selectivity patterns of these electrodes differ radically from that of a highly sulfate selective electrode based on a compound reported previously to be the analogous mononuclear 1 : 1 complex of zinc(II) and the same Schiff base. It is suggested that the previously reported 1 : 1 complex with zinc(II) may indeed have been a polymer of the same elemental composition. 相似文献
11.
This work reports the highly‐sensitive amperometric determination of free glycerol in biodiesel at a gold electrode adapted in a flow‐injection analysis (FIA) cell. The amperometric method involved the continuous application of three sequential pulses to the working electrode (+250 mV, +700 mV, and ?200 mV, for 100 ms each). This sequence of potential pulses eliminated electrode passivation and dramatically increased the analytical signal. The proposed FIA‐amperometric method presented low relative standard deviation between injections (1.5 %, n=15), high analytical frequency (85 h?1), satisfactory recovery values (93–118 %) for spiked samples, wide linear range (from 1 to 300 µmol L?1), and low detection limit (0.5 µmol L?1). 相似文献
12.
本文以2,9,16,23-四硝基酞菁铜(II) (Cu(II)TNPc) 和2,9,16,23-四氨基酞菁铜(II) (Cu(II)TAPc) 为载体制备PVC聚合膜,构建了水杨酸根选择性电极,并探讨了该电极的选择性响应性能。研究了增塑剂的性质、载体的含量及阴、阳离子添加剂对电极电位响应的影响。结果表明,基于Cu(II)TNPc为载体的PVC膜电极对水杨酸根 (Sal-) 呈现出优先选择性电位响应。具有最佳电位响应的电极的膜组成是:(w/w) 3.0% Cu(II)TNPc,67.0% o-NPOE,29.5% PVC和0.5% NaTPB。基于该组成的电极的线性响应范围为1.0×10-1-9.0×10-7 mol·L-1,检测下限为7.2×10-7 mol·L-1,斜率为-59.8±0.5 mV/decade;其响应快速,稳定性好,适宜的pH范围是3.0-7.0。并成功运用于了实际样品中水杨酸含量的测定,获得令人满意的结果。 相似文献
13.
G. Y. Aguilar Lira G. A. Álvarez Romero T. de J. Licona Sánchez M. E. Páez Hernández C. A. Galán Vidal M. A. Romero Romo 《Electroanalysis》2013,25(6):1519-1527
This work presents the results obtained on the construction of a potentiometric ion‐selective electrode based on a polypyrrole (PPy) selective membrane to quantify the benzoate ion in nonalcoholic beverages. The electrode modification with benzoate (Benz?1) ion doped‐Ppy was carried out under an imposed potential, while the electrosynthesis optimization was undertaken using the modified Simplex method, such that the film’s sensitivity was maximized toward the benzoate ion. The maximum sensitivity recorded was ?52.02±1.55 mV/decade [Benz?1] using a graphite powder‐araldite resin composite electrode. During the modified electrode’s characterization it was found out that the response and drift were relatively short, namely 2 min and 0.4 mV min?1 respectively, within the 7 to 9 pH range, exhibiting a detection limit of 7×10?4 mol L?1 and a quantification range of 3×10?3 at 10?1 mol L?1. Selectivity coefficients were evaluated with the Matched Potential Method obtaining in all cases values much less than 1. The benzoate concentration in commercially available juices and sweetened beverages was evaluated comparing the results obtained with the proposed ion‐selective electrode and those of HPLC, the usually accepted technique. A statistical analysis of the results led to the conclusion that there exists no meaningful difference between the results obtained with both techniques, which shows the usefulness of the ion‐selective electrode to proceed with the quantification in real samples. 相似文献
14.
本文报道了一种以牛磺酸双核铜络合物为中性载体的硫氰酸根PVC膜电极。该电极对硫氰酸根有良好的电位响应并呈现出anti-Hofmeister行为,其选择性顺序SCN->I->ClO4->Sal->NO3-> NO2-> Br- > Cl- > SO3-> SO4 2-。在20℃ pH 5.0的磷酸缓冲溶液中,其线性范围为1.0´10 -1~ 1.0´10-6mol×L-1,检测线为8.0×10 -7mol•L-1,斜率为 -56.5 mV/pcSCN-。紫外、红外和交流阻抗研究表明电极的高选择性与载体的立体结构和分析物与中心金属离子的作用相关。将该电极用于废水和人体尿液中硫氰酸根的测定,获得了较满意的结果。 相似文献
15.
根据除草剂对类囊体膜光合作用光系统II (PSII)的抑制效应 ,利用聚乙烯醇 -苯乙烯吡啶 (PVA SbQ)光聚合法固定类囊体膜 ,结合普鲁士蓝修饰电极对过氧化氢电还原的高灵敏、高选择性的催化作用 ,制成了用于安培法检测除草剂残留的生物活性膜修饰电极 .电极通过测量加入除草剂时类囊体膜光合作用产生过氧化氢的活性变化 ,对除草剂进行测定 .在含有 1 5× 10 -3 mol/LNaCl和 5× 10 -3 mol/LMgCl2 的pH =6 8磷酸盐缓冲溶液中 ,测量 0 0 5V处过氧化氢的还原电流的变化可以分别测定不同浓度的除草剂 ,检出限分别为敌草龙 3 6× 10 -9mol/L ,阿特拉津 6 1× 10 -9mol/L ,敌稗 8 7× 10 -9mol/L .普鲁士蓝作为电子中介体 ,显著增大了测定的灵敏度 . 相似文献
16.
A rapid, sensitive and selective procedure for determination of Cr(III) and Cr(VI) in environmental and industrial liquid samples via preconcentration with ammonium pyrrolidine dithiocarbamate (APDC) and determination by means of the EDXRF was described. The effect of pH in the range of 3-11 on the recovery of Cr(III) and Cr(VI) has been investigated separately and in combination of these two species. The influence of organic matter, carbonate species and elements V, Mn and Fe on the recovery of each chromium specie (separately/in combination) over whole pH range was also tested in order to simulate condition occurring in natural waters that usually contain certain amount of dissolved organic matter and carbonate ions. Cr(VI) and Cr(III) have shown different behaviors in reaction with APDC at different pH ranges and therefore it is possible to separate those two species. It was found that Cr(VI) creates complex with APDC only in the pH range from 3 to 5 with quantitative recovery (app. 98%) at pH 3, but there was no recovery of Cr(III) at that pH. On the contrary, in pH range from 6 to 11, reaction with Cr(III) and APDC reviled that the only reaction product is Cr(OH)3 instead of the expected Cr(III)-APDC complex. All reaction products were characterized by IR spectroscopy. 相似文献
17.
A new poly(vinyl chloride) (PVC) membrane ion‐selective electrode based on bis‐salicyladehyde‐diaminjodipropylamine (BSDDA) as an ion carrier was successfully applied to the detection of Hg2+ ions. This electrode displayed good selectivity toward Hg2+ in comparison with other metal ions and exhibited a Nernstian slope of 30.5 ± 0.4 mV per decade of Hg2+ over a concentration range of 9.5 × 10?7 to 6.4 × 10?2 M of Hg2+ in the pH range 1.5 to 3.5. The detection limit was 7.0 ± 0.2 × 10?7 M and response time was about 10 s to 25 s. The electrode can be used at least 2 months without apparent divergence in potential. In addition, the effects of experimental parameters such as membrane composition, nature and amounts of plasticizer and additive were investigated. The proposed electrode could be used as an indicator electrode in the detection of Hg2+ in samples. 相似文献
18.
Luiz Carlos S. de Figueiredo‐Filho Vagner B. dos Santos Bruno Campos Janegitz Thiago Brito Guerreiro Orlando Fatibello‐Filho Ronaldo Censi Faria Luiz Humberto Marcolino‐Junior 《Electroanalysis》2010,22(11):1260-1266
A bismuth‐film electrode (BiFE) ex situ electrochemically deposited onto a copper substrate has been presented for paraquat determination. The bismuth film was electrochemically deposited at an applied potential of ?0.18 V vs. Ag/AgCl (3.0 M KCl) for 200 s. The analytical curve was linear in the paraquat concentration range from 6.6×10?7 M to 4.8×10?5 M with a limit of detection of 9.3×10?8 M. The method presented satisfactory results at a confidence level of 95% and the performance was evaluated in water samples. 相似文献
19.
载体乳化液膜法同步进行亚稳相PbCrO4纳米粒子的仿生合成与铅铬废水的处理 总被引:7,自引:0,他引:7
采用一种新型的纳米材料仿生合成方法——载体乳化液膜法,在煤油-Span-80-N7301乳化液膜体系中,以电镀废水中常见的Cr(Ⅵ)溶液为外相,蓄电池、油漆等行业废水常见的Pb(Ⅱ)溶液为内相,通过对生物体内囊泡结构的形态和离子传输功能模拟,室温下成功合成了能稳定存在的直径为5~15nm的正交亚稳相PbCrO4纳米粒子.使用XRD,TEM对产物结构和形貌进行了表征.首次通过FT-IR和UV-vis对所得产物和普通块体材料的光学性质做了比较.并对乳化液膜体系控制产物晶型和尺寸的机理进行了初步的探讨.此方法也有望用于对不同类型工业废水的耦合处理. 相似文献
20.
Gizem Kaleli‐Can Busra Ozlu Hatice Ferda
zgüzar Baran Onal‐Ulusoy Gzde Kabay Taesik Eom Bong Sup Shim Mehmet Mutlu 《Electroanalysis》2020,32(8):1696-1706
A biosensor was prepared with natural melanin nanoparticles (MNP) decorated on a screen‐printed carbon electrode (SPCE). Hexavalent chromium was selected as a well‐known heavy metal ion to be detected for testing the performance of novel biosensor. Natural MNP was extracted from cuttlefish (Sepia officinalis) ink. Surface decoration of SPCEs with MNP was performed by two different methods. The first one was layer‐by‐layer assembly (LBL‐A) for different cycle times(n). In the second one, plasma treatment of SPCE incorporated with evaporation‐induced self‐assembly (EI‐SA) techniques including different incubation times in MNP solutions. The performance of both modified SPCEs were tested for amperometric detection of Cr(VI) in various water samples, and peak reduction of Cr(VI) was determined at 0.33 V. Amperometric results showed wide linear ranges of 0.1–2 μM and 0.1–5 μM of Cr(VI) for SPCEs modified with 14n‐LBL‐A and 12h‐EI‐SA, respectively. The sensitivities of SPCEs modified with 14n‐LBL‐A and 12h‐EI‐SA techniques were 0.27 μA μM?1 and 0.52 μA μM?1, respectively. In addition, both modified SPCEs selectively detected Cr(VI) in a model aqueous system composed of certain other heavy metals and minerals, and tap and lake water samples. The LOD and LOQ values for 12h‐EI‐SA were 0.03 μM and 0.1 μM, respectively. This showed that MNP‐modified‐SPCEs generated via EI‐SA techniques have the potential to be an alternative to conventional detection methods such as ICP‐MS. 相似文献