首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 12 毫秒
1.
《Electroanalysis》2004,16(22):1843-1851
Miniaturized solid‐state ion sensors based on field‐effect transistors on silicon can take advantage of the capabilities of microelectronics and microsystems technology for the integration of combined functionalities. Optimized solid‐state chemical sensors usually require specific materials and fabrication processes. However, if standard fabrication processes can be used, integrated chemical sensor systems can be developed in a shorter time and in a cost effective way. We show that, for applications in which a long operating time is not required, such as in disposable biomedical sensors, good integrated sensor systems can be fabricated with standard materials and processes. Specific examples are presented, such as multisensor systems, sensors with integrated signal‐processing circuits and sensors with particle manipulation electrodes.  相似文献   

2.
The human interleukine‐2 gene (hIL‐2) is detected with a label‐free DNA hybridization biosensor using a non‐inosine substituted probe. The sensor relies on the immobilization of a 20‐mer antisense single strand oligonucleotide (chIL‐2) related to the human interleukine‐2 gene on the pencil graphite electrode (PGE) as a probe. The guanine oxidation signal was monitored using anodic differential pulse voltammetry (ADPV). The electrochemical pretreatment of the polished PGE at 1.80 V for 5 min is suggested. Then, 5 min immobilization at 0.50 V was found as the optimum condition for immobilization of the probe. The electrochemical detection of hybridization between chIL‐2 and hIL‐2 as a target was accomplished. The selectivity of the biosensor was studied using noncomplementary oligonucleotides. Diagnostic performance of the biosensor is described and the detection limit is found 36 pg/μL.  相似文献   

3.
In this paper, nano‐gold modified carbon paste electrode (NGMCPE) was employed to develop an electrochemical DNA hybridization biosensor. The proposed sensor was made up by immobilization of 15‐mer single stranded oligonucleotide probe for detection of target DNA. Hybridization detection relies on the alternation in guanine oxidation signal following hybridization of the probe with complementary genomic DNA. The guanine oxidation was monitored using differential pulse voltammetry (DPV). Different factors such as activation potential, activation time and probe immobilization conditions were optimized. The selectivity of the sensor was investigated by non‐complementary oligonucleotides. Diagnostic performance of the biosensor was described and the detection limit was found 1.9 × 10?13 M at the NGMCPE surface. All of the investigations were performed in both CPE and NGMCPE and finally their results were compared.  相似文献   

4.
A novel DNA biosensor has been fabricated for the detection of DNA hybridization based on layer‐by‐layer (LBL) covalent assembly of gold nanoparticles (GNPs) and multiwalled carbon nanotubes (MWCNTs). The stepwise LBL assembly process was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The hybridization events were monitored by differential pulse voltammetry (DPV) measurement of the intercalated doxorubicin, and the factors influencing the performance of the DNA hybridization was investigated in detail. The signal was linearly changed with target DNA concentration increased from 0.5 to 0.01 nM, and had a detection limit of 7.5 pM (signal/noise ratio of 3). In addition, the DNA biosensor showed an excellent reproducibility and stability under the DNA‐hybridization conditions.  相似文献   

5.
《Electroanalysis》2006,18(9):873-881
In this paper, we present an impedance‐based DNA biosensor using thionine intercalation to amplify DNA hybridization signal. Beacon single‐stranded DNA (ssDNA) probe and mercaptoacetic acid were self‐assembled onto a Au electrode by forming Au? S bonds. These beacon ssDNAs were hybridized with the complementary sequences around the loop structure. Then thionine was intercalated into the double‐stranded DNA (dsDNA) immobilized on the Au electrode surface. Due to the neutralization of the negative charges of dsDNA by the intercalated thionine, the electronic transfer resistance (Ret) of the DNA modified Au electrode was significantly diminished. Herein, the decreased value of Ret resulted from the thionine intercalating into dsDNA was employed as the hybridization signal. SDS was used to reduce the unspecific adsorption between ssDNA and thionine. Several experimental conditions, including the surface coverage of ssDNA probe on Au electrode, the hybridization temperature and time were all optimized. Moreover, the hybridization reactions of the unstructured linear ssDNA probe and the structured beacon ssDNA probe with their complementary sequences were compared in this work. The sensitivity of the presented DNA biosensor highlighted that the intercalation of thionine into dsDNA was an efficient approach to amplify the hybridization signal using impedance detection technique. Additionally, in this DNA biosensing protocol, beacon ssDNA has a good ability to distinguish target DNA sequences. This results in a higher specificity than using traditional unstructured DNA probe.  相似文献   

6.
The development of a DNA biosensor for the detection of cylindrospermopsin, based on self‐assembled monolayers (SAMs) of 4‐aminothiophenol, is investigated. SAMs were characterized by electrochemical reductive desorption. Detection of probe immobilization and hybridization has been achieved by cyclic and square‐wave voltammetry (SWV), using methylene blue (MB) as electroactive indicator. The SWV data obtained in phosphate buffer, with and without NaCl, after MB accumulation, revealed an increase of the redox indicator current peaks after the hybridization step. This behavior is consistent with MB intercalation into DNA, for high ionic strength media and attributed to electrostatic interactions in the absence of salt. Evidence for surface modification is also provided by atomic force microscopy and ellipsometry.  相似文献   

7.
《Electroanalysis》2006,18(2):141-151
Molecular diagnostics of inherited neurodegenerative disorders such as fragile X syndrome, myotonic dystrophy or Friedreich ataxia (FRDA) is based on analysis of the length of trinucleotide repetitive sequences in certain loci of genomic DNA. The current methods employ PCR and electrophoretic determination of the amplified DNA fragment size. We have recently shown that length of a triplet repetitive DNA sequence can be determined using a double‐surface electrochemical technique involving multiple hybridization of the expanded triplet repeat with short labeled reporter probe (spanning several trinucleotides). Here we propose a single‐surface sensor employing an analogous principle. Target DNA (tDNA) is adsorbed onto surface of a carbon (pyrolytic graphite or screen‐printed) electrode. Biotin‐labeled reporter probe (RP) is hybridized with the immobilized tDNA followed by binding of streptavidin‐alkaline phosphatase (ALP) conjugate. The ALP catalyzes production of an electroactive indicator (1‐naphthol) which is detected voltammetrically on the same electrode. Signal resulting from this electrochemical enzyme‐linked DNA hybridization assay is normalized to the amount of tDNA immobilized at the transducer surface either by measuring intrinsic tDNA voltammetric response, or using electrochemical labeling of the tDNA with osmium tetroxide 2,2′‐bipyridine complex. Detection of (GAA)n?(TTC)n triplet repeat expansion in nanogram quantities of PCR‐amplified tDNAs, including amplicons of patients' genomic DNA, is demonstrated. We show that our technique allow differentiation between normal and pathological alleles of X25 gene related to the FRDA.  相似文献   

8.
In this article, we report on efforts to construct a high sensitive electrochemical sensor with immobilized sandwich‐type DNA borne ferrocene (Fc) head for sequence‐specific DNA detection using ultramicroelectrode and low current voltammetry. Based on the difference in deformability between the bending rigid complementary DNA double helix and its anomalous flexile mismatches, the fully complementary target can be distinguished from mismatched targets including the single‐base mismatched target. Detection limit estimated as the amount of DNA is observed to be 100 fM via low current voltammetry. The method offers great promise of high sensitivity and selectivity simultaneously for effective gene identification.  相似文献   

9.
A DNA‐based biosensor was reported for detection of silver ions (Ag+) by electrochemical impedance spectroscopy (EIS) with [Fe(CN)6]4?/3? as redox probe and hybridization chain reaction (HCR) induced hemin/G‐quadruplex nanowire as enhanced label. In the present of target Ag+, Ag+ interacted with cytosine‐cytosine (C? C) mismatch to form the stable C? Ag+? C complex with the aim of immobilizing the primer DNA on electrode, which thus triggered the HCR to form inert hemin/G‐quadruplex nanowire with an amplified EIS signal. As a result, the DNA biosensor showed a high sensitivity with the concentration range spanning from 0.1 nM to 100 µM and a detection limit of 0.05 nM.  相似文献   

10.
11.
《Electroanalysis》2017,29(7):1810-1819
Pirarubicin (THP) is an anthracycline drug, which is mainly used in the anticancer treatment. Utilization of THP may be associated with many dangerous side effects, therefore monitoring of drug level in patients’ organism is an important aspect of chemotherapy. In our research we focused on designing of an electrochemical DNA‐based biosensor for selective detection of pirarubicin (THP). Our biosensor utilizes the ability of pirarubicin to interact with DNA double helix and the fact that THP is an electrochemically active compound. Graphite electrodes modified with DNA enable to obtain nearly three thousand times higher sensitivity (41.8⋅103 A/M) than non‐modified sensors. Furthermore, in the case of THP detection by means of bare graphite electrodes, LOD was 43.6⋅10−9 M, whereas for developed DNA biosensors ‐112⋅10‐12 M. A study of selectivity of DNA–modified biosensors was carried out in aqueous solutions containing interferents: acetaminophen (PCT) and ascorbic acid (AA) as well as in samples of fetal bovine serum (FBS) spiked with PCT and AA. In established measurement conditions one peak corresponding to THP reduction was observed, whereas no redox peaks assigned to interferents (PCT, AA) were present. These results indicate that developed biosensors are selective to pirarubicin.  相似文献   

12.
食管鳞状细胞癌(ESCC)患者发病早期由于体内的肿瘤标志物种类少且含量低,难以在患病早期发现疾病从而快速反应并有效治疗.因此,找到一种合适的标志物对其进行快速高效检测是研究者亟待解决的问题.血小板衍生生长因子(PDGF-BB)在恶性肿瘤的早期诊断中具有极其重要的地位.该文基于酶循环放大荧光光谱设计了一种用于PDGF-B...  相似文献   

13.
In this study, a sandwich‐type electrochemical enzyme‐based LNA‐modified DNA biosensor was developed to detect relative gene in chronic Myelogenous Leukemia first. This biosensor is based on a ‘sandwich’ detection strategy, which involves a pair of probes (a capture probe immobilized at the electrode surface and a reporter probe labeled biotin as an affinity tag for avidin‐HRP) modified LNA. Since biotin can be connected with avidin‐HRP, this biosensor offers an enzymatically amplified electrochemical current signal for the detection of target DNA. This new pattern exhibits high sensitivity and selectivity, and this biosensor has been used for an assay of PCR real sample with satisfactory result.  相似文献   

14.
The antidiabetic drug metformin (MET) is one of a group of emerging pharmaceutical drug contaminants in the wastewater treatment plants. The electrochemical behaviour of MET?Cu(II) complex by differential pulse and square wave voltammetry, in a wide pH range, at a glassy carbon electrode modified with a carbon black dihexadecylphosphate film (CB?DHP/GCE), was investigated. The MET?Cu(II) complex oxidation showed one pH‐dependent process, which leads to the formation of an oxidation product, being oxidized at a lower potential. The electroanalytical MET?Cu(II) complex detection limit, LOD=0.63 μM, and quantification limit, LOQ=2.09 μM, were obtained, and the MET?Cu(II) complex determination in wastewater samples collected from a senior residence effluent, using the CB?DHP/GCE, was achieved. Considering MET toxicity, the electrochemical evaluation of MET?dsDNA interaction, in incubated solutions and using dsDNA‐electrochemical biosensors, following the changes in the oxidation peaks of guanosine and adenosine residues electrochemical currents, was also investigated. The MET?dsDNA interaction mechanism, for shorter times, occurs by the binding of MET molecules in the minor grooves of the dsDNA, and for long times, the stabilization of the MET?dsDNA complex, causing a local distortion and/or unwinding of dsDNA morphology, is described. However, MET did not promote DNA oxidative damage.  相似文献   

15.
《Analytical letters》2012,45(3):467-482
Abstract

This paper describes a reagentless electrochemical DNA biosensor applied to the detection of human immunodeficiency virus (HIV) sequences based on electrochemical impedance spectroscopy (EIS). The novel DNA biosensor has been elaborated by means of an opposite‐charged adsorption Au‐Ag nanocomposite to a conductive polymer polypyrrole (PPy) modified platinum electrode (Pt) and self‐assembly the mercapto oligonucleotide probes onto the surface of modified electrode via the nanocomposite. The duplex formation was detected by measuring the electrochemical impedance signal of nucleic acids in phosphate buffer solution (PBS). Such response is based on the concomitant conductivity changes of the PPy film and nanocomposite. The reagentless scheme has been characterised using 21‐mer synthetic oligonucleotides as models: parameters affecting the hybridization assay were explored and optimized. The detection limit is 5.0×10?10 M of target oligonucleotides at 3σ. The potential for development of reagentless DNA hybridization analysis in the clinical diagnosis is being pursued.  相似文献   

16.
Development of electrochemical DNA hybridization biosensors based on carbon paste electrode (CPE) and gold nanoparticle modified carbon paste electrode (NGMCPE) as transducers and ethyl green (EG) as a new electroactive label is described. Electrochemical impedance spectroscopy and cyclic voltammetry techniques were applied for the investigation and comparison of bare CPE and NGMCPE surfaces. Our voltammetric and spectroscopic studies showed gold nanoparticles are enable to facilitate electron transfer between the accumulated label on DNA probe modified electrode and electrode surface and enhance the electrical signals and lead to an improved detection limit. The immobilization of a 15‐mer single strand oligonucleotide probe on the working electrodes and hybridization event between the probe and its complementary sequence as a target were investigated by differential pulse voltammetry (DPV) responses of the EG accumulated on the electrodes. The effects of some experimental variables on the performance of the biosensors were investigated and optimum conditions were suggested. The selectivity of the biosensors was studied using some non‐complementary oligonucleotides. Finally the detection limits were calculated as 1.35×10?10 mol/L and 5.16×10?11 mol/L on the CPE and NEGCPE, respectively. In addition, the biosensors exhibited a good selectivity, reproducibility and stability for the determination of DNA sequences.  相似文献   

17.
18.
High‐performance electrodes for in vivo electrochemical detection of glucose (GO) are highly desirable. In this work, we propose a new approach to efficiently and precisely prepare a Au nanowire array electrode (ANAE) with a line width of 78 nm and a large sensor area of 60 mm×60 mm for GO detection. In this approach three techniques, i.e., vacuum sputtering‐deposition, holography photolithography, and argon ion‐beam etching, are integrated. The fabricated ANAE exhibits good performance for GO detection. A linear amperometric response to the oxidation of GO in a concentration range of 0.4–10 mM is observed. The ANAE is characterized by its high detection sensitivity, selectivity, stability and good biocompatibility. All of these make it a promising tool for GO detection and other relevant applications.  相似文献   

19.
Organophosphate (OP) and carbamate pesticides exert their toxicity via attacking the hydroxyl moiety of serine in the ‘active site’ of acetylcholinesterase (AChE). In this paper we developed a stable AChE biosensor based on self‐assembling AChE to graphene nanosheet (GN)‐gold nanoparticles (AuNPs) nanocomposite electrode for investigation of inhibition, reactivation and aging processes of different pesticides. It is confirmed that pesticides can inhibit AChE in a short time. OPs poisoning is treatable with oximes while carbarmates exposure is insensitive to oximes. The proposed electrochemical approach thus provides a new simple tool for comparison of pesticide sensitivity and guide of therapeutic intervention.  相似文献   

20.
A gold surface modified with a self‐assembled monolayer of 11‐amino‐1‐undecanethiol (AUT) was used for the covalent immobilization of oxidized single‐walled carbon nanotubes (SWNTs). The as‐described SWNTs‐modified substrate was subsequently used to attach single‐stranded deoxyribonucleic acid (ssDNA) used as a substrate for DNA hybridization. Electrochemical impedance spectroscopy measurements were performed to follow the DNA hybridization process by using the redox couple [Fe(CN)6]3−/4− as a marker ion. Specifically, changes in charge transfer resistance obtained from the Nyquist plots were used as the sensing parameter of DNA hybridization. The substrate sensitivity towards changes in target DNA concentration, its selectivity toward different DNA sequences and its reusability are successfully demonstrated in this report.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号