首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The voltammetric behavior of 3‐nitrofluoranthene and 3‐aminofluoranthene was investigated in mixed methanol‐water solutions by differential pulse voltammetry (DPV) at boron doped diamond thin‐film electrode (BDDE). Optimum conditions have been found for determination of 3‐nitrofluoranthene in the concentration range of 2×10?8–1×10?6 mol L?1, and for determination 3‐aminofluorathnene in the concentration range of 2×10?7–1×10?5 mol L?1, respectively. Limits of determination were 3×10?8 mol L?1 (3‐nitrofluoranthene) and 2×10?7 mol L?1 (3‐aminofluoranthene).  相似文献   

2.
A carbon paste electrode spiked with 1‐[4‐ferrocenyl ethynyl) phenyl]‐1‐ethanone (4FEPE) was constructed by incorporation of 4FEPE in graphite powder‐paraffin oil matrix. It has been shown by direct current cyclic voltammetry and double step chronoamperometry that this electrode can catalyze the oxidation of tryptophan (Trp) in aqueous buffered solution. It has been found that under optimum condition (pH 7.00), the oxidation of Trp at the surface of such an electrode occurs at a potential about 200 mV less positive than at an unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, α and rate constant for the chemical reaction between Trp and redox sites in 4FEPE modified carbon paste electrode (4FEPEMCPE) were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of Trp showed a linear dependent on the Trp concentrations and linear calibration curves were obtained in the ranges of 6.00×10?6 M–3.35×10?3 M and 8.50×10?7 M–6.34×10?5 M of Trp concentration with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods, respectively. The detection limits (3σ) were determined as 1.80×10?6 M and 5.60×10?7 M by CV and DPV methods. This method was also examined as a selective, simple and precise new method for voltammetric determination of tryptophan in real sample.  相似文献   

3.
A voltammetric study of the oxidation of Ceftazidime (CEFT) has been carried out at the glassy carbon electrode by cyclic, differential pulse (DPV) and square wave (SWV) voltammetry. The oxidation of CEFT was irreversible and exhibited diffusion controlled process depending on pH. The oxidation mechanism was proposed and discussed. According to the linear relationship between the peak current and concentration, DPV and SWV voltammetric methods for CEFT assay in pharmaceutical dosage forms and human urine were developed. For analytical purposes, a well resolved diffusion controlled voltammetric peak was obtained in 0.1 M H2SO4 at 1.00 and 1.02 V for differential pulse and square wave voltammetric techniques, respectively. The linear response was obtained within the range of 4 × 10?6?8 × 10?5 M with a detection limit of 6 × 10?7 M for differential pulse and 4 × 10?6–2 × 10?4 M with a detection limit of 1 × 10?6 M for square wave voltammetric technique. The determination of CEFT in 0.1 M H2SO4 was possible over the 2 × 10?6–1 × 10?4 M range in urine sample for both techniques. The standard addition method was used for the recovery studies.  相似文献   

4.
《Analytical letters》2012,45(12):1913-1931
Abstract

A voltammetric study of the oxidation of fexofenadine HCl (FEXO) has been carried out at the glassy carbon electrode. The electrochemical oxidation of FEXO was investigated by cyclic, linear sweep, differential pulse (DPV), and square wave (SWV) voltammetry using glassy carbon electrode. The oxidation of FEXO was irreversible and exhibited diffusion‐controlled process depending on pH. The dependence of intensities of currents and potentials on pH, concentration, scan rate, nature of the buffer was investigated. Different parameters were tested to optimize the conditions for the determination of FEXO. For analytical purposes, a very well resolved diffusion‐controlled voltammetric peak was obtained in Britton‐Robinson buffer at pH 7.0 with 20% constant amount of methanol for DPV and SWV techniques. The linear response was obtained in supporting electrolyte in the ranges of 1.0×10?6–2.0×10?4 M with a detection limit of 6.6×10?9 M and 5.76×10?8 M and in serum samples in the ranges of 2.0×10?6–1.0×10?4 M with a detection limit of 8.08×10?8 M and 4.97×10?8 M for differential pulse and square wave voltammetric techniques, respectively. Only square wave voltammetric technique can be applied to the urine samples, and the linearity was obtained in the ranges of 2.0×10?6–1.0×10?4 M with a detection limit of 2.00×10?7 M. Based on this study, simple, rapid, selective and sensitive two voltammetric methods were developed for the determination of FEXO in dosage forms and biological fluids. For the precision and accuracy of the developed methods, recovery studies were used. The standard addition method was used for the recovery studies. No electroactive interferences were found in biological fluids from the endogenous substances and additives present in tablets.  相似文献   

5.
《Electroanalysis》2004,16(12):1051-1058
The voltammetric behavior of α‐ketoglutarate (α‐KG) at the hanging mercury drop electrode (HMDE) has been investigated in acetate buffer solution. Under the optimum experimental conditions (pH 4.5, 0.2 M NaAc‐HAc buffer solution), a sensitive reductive wave of α‐KG was obtained by linear scan voltammetry (LSV) and the peak potential was ?1.18 V (vs. SCE), which was an irreversible adsorption wave. The kinetic parameters of the electrode process were α=0.3 and ks=0.72 1/s. There was a linear relationship between peak current ip, α‐KG and α‐KG concentration in the range of 2×10?6–8×10?4 M α‐KG. The detection limit was 8×10?7 M and the relative standard deviation was 2.0% (Cα‐KG=8×10?4 M, n=10). Applications of the reductive wave of α‐KG for practical analysis were addressed as follows: (1) It can be used for the quantitative analysis of α‐KG in biological samples and the results agree well with those obtained from the established ultraviolet spectrophotometric method. (2) Utilizing the complexing effect between α‐KG and aluminum, a linear relationship holds between the decrease of peak current of α‐KG Δip and the added Al concentration Cequation/tex2gif-inf-5.gif in the range of 5.0×10?6–2.5×10?4 M. The detection limit was 2.2×10?6 M and the relative standard deviation was 3.1% (Cequation/tex2gif-inf-6.gif=4×10?5 M, n=10). It was successfully applied to the detection of aluminum in water and synthetic biological samples with satisfactory results, which were consistent with those of ICP‐AES. (3) It was also applied to study the effect of AlIII on the glutamate dehydrogenase (GDH) activity in the catalytically reaction of α‐KG+NH +NADH?L ‐glutamate+NAD++H2O by differential pulse polarography (DPP) technique. By monitoring DPP reductive currents of NAD+ and α‐KG, an elementary important result was found that Al could greatly affect the activity of GDH. This study could be attributed to intrinsic understanding of the aluminum's toxicity in enzyme reaction processes.  相似文献   

6.
《Electroanalysis》2006,18(2):127-130
The voltammetric behavior of 2‐methyl‐4,6‐dinitrophenol was investigated by differential pulse voltammetry (DPV) at a nontoxic mercury meniscus‐modified silver solid amalgam electrode (m‐AgSAE). Conditions have been found for its determination by DPV at m‐AgSAE in the concentration range of 0.2 to 1 μmol L?1.  相似文献   

7.
A glassy carbon electrode (GCE) modified with Mg‐Al‐SDS hydrotalcite‐like clay (SDS‐HTLC) was used for the sensitive voltammetric determination of 2‐nitrophenol (2‐NP) utilizing the oxidation process. The results indicate the prepared modified electrode has an excellent electrocatalytic activity toward 2‐NP oxidation, lowering the oxidation overpotential and increasing the oxidation current. Under optimal conditions, the oxidation current was proportional to 2‐NP concentration in the range from 1.0×10?6 to 6.0×10?4 M with the detection limit of 5.0×10?7 M by DPV (S/N=3). The fabricated electrode was applied for 2‐NP determination in water samples and the recovery for these samples was from 95.6 to 103.5%.  相似文献   

8.
Simple, sensitive, accurate and inexpensive differential pulse (DPV) and square wave (SWV) voltammetric methods utilizing zeolite modified carbon paste electrode (ZMCPE) were developed for the determination of Oxymetazoline hydrochloride (OXM) in nasal drops. Various experimental parameters were optimized using cyclic voltammetry (CV). Calibration curves were linear over the concentration ranges 9.8×10−8–3.6×10−6 M and 9.8×10−6–9×10−5 M for DPV and SWV, respectively. The DPV method showed a limit of detection (LOD) of 1.04×10−7 M. The method was applied for the determination of OXM in pharmaceutical formulation with an average recovery of 101.18 % (%RSD=0.41, n=9).  相似文献   

9.
The formation of an inclusion complex between 4‐aminobiphenyl (4‐AB) and β‐cyclodextrin molecules (β‐CD), allows the use of thiolated β‐CDs as chemi‐adsorbed material on a Au electrode as a self‐assembled submonolayer for the selective square wave voltammetric determination of 4‐AB. The submonolayer was characterized by reductive desorption and an association constant of 1.2×104 L/mol was obtained. The optimization of variables yielded a linear dependence of ip/4‐AB concentration in the range of 10?5 to 10?4 mol/L. The selectivity of the method was evaluated in the presence of other aromatic amines obtaining better results with the modified electrode. This methodology was applied to the voltammetric determination of 4‐AB in wastewater samples.  相似文献   

10.
《Electroanalysis》2006,18(17):1722-1726
The electrochemical properties of L ‐cysteic acid studied at the surface of p‐bromanil (tetrabromo‐p‐benzoquinone) modified carbon paste electrode (BMCPE) in aqueous media by cyclic voltammetry (CV) and double step potential chronoamperometry. It has been found that under optimum condition (pH 7.00) in cyclic voltammetry, the oxidation of L ‐cysteic acid at the surface of BMCPE occurs at a half‐wave potential of p‐bromanil redox system (e.g., 100 mV vs. Ag|AgCl|KClsat), whereas, L ‐cysteic acid was electroinactive in the testing potential ranges at the surface of bare carbon paste electrode. The apparent diffusion coefficient of spiked p‐bromanil in paraffin oil was also determined by using the Cottrell equation. The electrocatalytic oxidation peak current of L ‐cysteic acid exhibits a linear dependency to its concentration in the ranges of 8.00×10?6 M–6.00×10?3 M and 5.2×10?7 M–1.0×10?5 M using CV and differential pulse voltammetry (DPV) methods, respectively. The detection limits (2σ) were determined as 5.00×10?6 M and 4.00×10?7 M by CV and DPV methods. This method was used as a new, selective, rapid, simple, precise and suitable voltammetric method for determination of L ‐cysteic acid in serum of patient's blood with migraine disease.  相似文献   

11.
《Analytical letters》2012,45(14):2322-2338
Abstract

A differential pulse (DP) and square wave (SW) voltammetric techniques were developed for the determination of irbesartan. The electrochemical behavior of irbesartan was investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and square wave voltammetry (SWV) at the hanging mercury drop electrode (HMDE). Different parameters were tested to optimize the conditions of the determination. It was found that in the range of 8 × 10?6–1 × 10?4 M, the currents measured by both of methods presented a good linear property as a function of the concentration of irbesartan. In addition, validation parameters, such as reproducibility, sensitivity, and recovery were evaluated as well. The slope of the log Ip- log ν linear plot was 0.58 indicating the diffusion control for 0.5 M sulphuric acid without the need for separation or complex sample preparation, since there was no interference from the excipients and endogenous substances.

The methods were successfully applied to the analysis of irbesartan in the pharmaceutical tablet formulations and in human serum samples.  相似文献   

12.
《Electroanalysis》2003,15(22):1778-1781
The voltammetric behavior of N,N‐dimethyl‐4‐amino‐2′‐carboxyazobenzene was investigated by differential pulse voltammetry (DPV) at a mercury meniscus‐modified silver solid amalgam electrode (m‐AgSAE). Conditions have been found for its determination by DPV at m‐AgSAE in the concentration range of 0.4 to 15 μmol L?1.  相似文献   

13.
A new sensor, gold‐6‐amino‐2‐mercaptobenzothiazole (6A2MBT), was fabricated via a self‐assembly procedure. Electrochemical properties of the monolayer were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The modified electrode showed excellent antifouling property against the oxidation products of DA, allowed us to construct a dynamic calibration curve with two linear parts, 1.00×10?6 to 3.72×10?4 and 3.72×10?4 to 6.42×10?4 M DA, with correlation coefficients of 0.997 and 0.992 and a detection limit of 1.57×10?7 M DA by using differential pulse voltammetry (DPV), respectively. Finally, the performance of the Au‐6A2MBT modified electrode was successfully tested for electrochemical detection of DA in a pharmaceutical sample.  相似文献   

14.
《Electroanalysis》2003,15(13):1121-1128
Melatonin hormone plays an important role in many distinct physiological functions. A fully validated, sensitive and reproducible square‐wave cathodic adsorptive stripping voltammetric procedure was described for determination of melatonin in bulk form, tablets and human serum. The procedure was based on the reduction of the adsorptive hormone onto a hanging mercury drop electrode. Reduction behavior of melatonin was studied in both Britton‐Robinson (pH 2–11) and acetate (4.5–5.5) buffers. Acetate buffer of pH 5.0 was found reasonable as a supporting electrolyte for assay of the drug. The square‐wave cathodic adsorptive stripping voltammogram of melatonin showed a single well‐defined peak at ?1.45 V (vs. Ag/AgCl/KCls) using an accumulation potential of ?0.65 V. This peak may be attributed to the reduction of C?O double bond of the amide functional group of the reactant molecule. A mean recovery for 1×10?8 M melatonin in bulk form followed 30 s accumulation of 98.87%±0.78 and a detection limit of 3.13×10?10 M were achieved. The proposed procedure was successfully applied for the determination of the drug in tablets and human serum with mean recoveries of 97.68%±0.57 and 101.67%±0.85, respectively. A detection limit of 8.80×10?10 M was achieved for the determination of the drug in human serum. Results of the proposed method were comparable and coincided with those obtained by reported method. Vitamin B6 and common excipients, which are co‐formulated with melatonin, did not interfere. Also the effect of some interfering compounds such as serotonin, tryptophan and 5‐hydroxytryptophan on the determination of melatonin in human serum was studied, and all have no significant effect on the assay recovery.  相似文献   

15.
《Electroanalysis》2006,18(12):1193-1201
A chemically modified carbon paste electrode with 2,7‐bis(ferrocenyl ethyl)fluoren‐9‐one (2,7‐BFEFMCPE) was employed to study the electrocatalytic oxidation of ascorbic acid in aqueous solution using cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The diffusion coefficient (D=1.89×10?5 cm2 s?1), and the kinetic parameter such as the electron transfer coefficient, α (=0.42) of ascorbic acid oxidation at the surface of 2,7‐BFEFMCPE was determined using electrochemical approaches. It has been found that under an optimum condition (pH 7.00), the oxidation of ascorbic acid at the surface of such an electrode occurs at a potential about 300 mV less positive than that of an unmodified carbon paste electrode. The catalytic oxidation peak currents show a linear dependence on the ascorbic acid concentration and linear analytical curves were obtained in the ranges of 8.0×10?5 M–2.0×10?3 M and 3.1×10?5 M–3.3×10?3 M of ascorbic acid with correlation coefficients of 0.9980 and 0.9976 in cyclic voltammetry and differential pulse voltammetry, respectively. The detection limits (2δ) were determined to be 2.9×10?5 M and 9.0×10?6 M with cyclic voltammetry and differential pulse voltammetry, respectively. This method was also examined for determination of ascorbic acid in pharmaceutical preparations.  相似文献   

16.
《Electroanalysis》2018,30(5):943-954
A simple voltammetric nanosensor was described for the highly sensitive determination of antiviral drug Tenofovir. The benzalkonium chloride and silver nanoparticles were associated to build a nanosensor on glassy carbon electrode. Surface characterictics were achieved using scanning electron microscopic technique. The voltammetric measurements were performed in pH range between 1.0 and 10.0 using cyclic, adsorptive stripping differential pulse and adsorptive stripping square wave voltammetry. The linear dependence of the peak current on the square root of scan rates and the slope value (0.770) demonstrated that the oxidation of tenofovir is a mix diffusion‐adsorption controlled process in pH 5.70 acetate buffer. The linearity range was found to be 6.0×10−8–1.0×10−6 M, and nanosensor displayed an excellent detection limit of 2.39×10−9 M by square wave adsorptive stripping voltammetry. The developed nanosensor was successfully applied for the determination of Tenofovir in pharmaceutical dosage form. Moreover, the voltammetric oxidation pathway of tenofovir was also investigated at bare glassy carbon electrode comparing with some possible model compounds (Adenine and Adefovir).  相似文献   

17.
A simple and novel flow‐injection chemiluminescence (FI‐CL) method was established for the determination of 2‐Methoxyestradiol (2‐ME) in pharmaceutical preparations and biological fluids. The method was based on the significant enhancement of the CL from the KMnO4‐Na2SO3 reaction by 2‐ME in acidic medium. Under optimized conditions, the CL intensity was correlated linearly with concentration of 2‐ME in the range of 5.0 × 10?8‐5.0 × 10?6 M (r = 0.9995). The detection limit (3σ) of 2‐ME was 7.5 × 10?9 M and the relative standard deviation was 0.8% at 5.0 × 10?7 M 2‐ME (n = 8). The proposed method was successfully applied for the flow‐injection CL determination of 2‐ME in pharmaceutical preparations and biological fluids with the recoveries from 92.4 to 106.8%. The possible CL reaction mechanism was also discussed briefly.  相似文献   

18.
《Electroanalysis》2006,18(22):2225-2231
The mechanism of electrochemical behavior of catechol in the presence of thiaproline is investigated by cyclic voltammetry, controlled‐potential coulometry and spectrophotometric tracing of the reaction coordinate. The results indicate that thiaproline participate in with an ECEC mechanism in a nucleophilic (Michael) addition to o‐quinone. Effect of pH of buffer solution on reaction pathway is studied and showed that addition of thiaproline to the o‐quinone is performed only in solutions with pHs higher than 5. These results indicate that the addition of thiaproline is occurred first from amine functional group. In the second step, the addition of carboxylate group of thiaproline to C‐5 of catechol results the final product with a lactone ring in its structure. Observation of two isosbestic point in absorption spectrum during the progress of the electrolysis together with the FT‐IR results for final product can be presented as evidence for two step addition of thiaproline to catechol. Final product, due to the electron donor property of thiaproline, more easily oxidized respect to the former catechol and as a result, a new redox couple is obtained for this compound in lower potentials. The easier anodic oxidation of addition product (relative to catechol) caused to an increase in anodic current for catechol, which is proportional to the thiaproline concentration. The differential pulse voltammetry (DPV) is applied as a sensitive voltammetric method for the detection of thiaproline. A linear range from 5×10?8 to 5×10?6 M with a detection limit of 1×10?8 M is resulted for thiaproline. With respect to the reversibility of the electrochemical reactions in the mechanism, and also more facile oxidation of the addition products, the square‐wave voltammetry is presented as a method with considerably more sensitivity for the detection of sub‐micromolar amounts of thiaproline. The advantageous properties of the voltammetric method for thiaproline detection lie in its excellent catalytic activity, sensitivity and simplicity.  相似文献   

19.
The electrooxidation of hyoscine N‐butylbromide (HBB) was investigated by rotating disk electrode voltammetry, cyclic voltammetry and controlled potential coulometry in 0.1 M HNO3 and in 0.1 M tetrabutylammonium perchlorate (TBAP) solutions of acetonitrile at a platinum (Pt) electrode. Based on the results obtained, it is suggested that a bromide ion of HBB was oxidized in one reversible step in aqueous solutions and in two reversible steps in acetonitrile. A differential pulse voltammetric (DPV) method at a Pt electrode was developed for the determination of HBB in the concentration range of 1.0 × 10?6‐1.0 × 10?3 M. The procedure was applied to the determination of HBB in its formulations as well as its recovery from blood serum and urine samples.  相似文献   

20.
For the first time, a novel carbon nanotube bed electrode impregnated with silver–nanoparticles (AgNPs) for the determination of trace amounts of gabapentin (GBP) is described. We synthesized the AgNPs via a new procedure. The voltammetric behavior of the electrode was investigated by cyclic voltammetry. There were linear relationships in the ranges from 3.1×10?9 to 2.9×10?2 M and from 1.0×10?8 to 1.0×10?2 GBP with square wave and differential pulse voltammetric peak currents, respectively. The detection limits were 5.6×10?10 and 9.7×10?9 M, respectively. The electrode showed excellent response over a period of 2 months and was successfully applied in human plasma and pharmaceutical capsular products.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号