首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BACKGROUND: During the past decade, Taxol has assumed an important role in cancer chemotherapy. The search for novel compounds with a mechanism of action similar to that of Taxol, but with greater efficacy particularly in Taxol-resistant cells, has led to the isolation of new natural products. One such compound, (+)-discodermolide, although structurally distinct from Taxol, has a similar ability to stabilize microtubules. In addition, (+)-discodermolide is active in Taxol-resistant cell lines that overexpress P-glycoprotein, the multidrug-resistant transporter. Interestingly, (+)-discodermolide demonstrates a profound enhancement of the initiation process of microtubule polymerization compared to Taxol. RESULTS: The synthesis of (+)-discodermolide analogs exploiting our highly efficient, triply convergent approach has permitted structure-activity relationship (SAR) studies. Small changes to the (+)-discodermolide structure resulted in a dramatic decrease in the ability of all four discodermolide analogs to initiate tubulin polymerization. Two of the analogs also demonstrated a decrease in total tubulin polymerization, while a change in the olefin geometry at the C8 position produced a significant decrease in cytotoxic activity. CONCLUSIONS: The availability of (+)-discodermolide and the analogs, and the resultant SAR analysis, have permitted an exploration of the similarities and differences between (+)-discodermolide and Taxol. Docking of the X-ray/solution structure of (+)-discodermolide into the Taxol binding site of beta-tubulin revealed two possible binding modes (models I and II). The preferred pharmacophore model (I), in which the C19 side chain of (+)-discodermolide matches with the C2 benzoyl group of Taxol and the delta-lactone ring of (+)-discodermolide overlays with the C13 side chain of Taxol, concurred with the results of the SAR analysis.  相似文献   

2.
The anticancer drug paclitaxel (Taxol) exhibits paradoxical and poorly understood effects against slow‐growing tumors. To investigate its biological activity, fluorophores such as Oregon Green have been linked to this drug. However, this modification increases its polarity by approximately 1000‐fold and reduces the toxicity of Taxol towards cancer cell lines by over 200‐fold. To construct more drug‐like fluorescent probes suitable for imaging by confocal microscopy and analysis by flow cytometry, we synthesized derivatives of Taxol linked to the drug‐like fluorophore Pacific Blue (PB). We found that PB‐Gly‐Taxol bound the target protein β‐tubulin with both high affinity in vitro and high specificity in living cells, exhibited substantial cytotoxicity towards HeLa cells, and was a highly sensitive substrate of the multidrug resistance transporter P‐glycoprotein (P‐gp).  相似文献   

3.
The Cysteamine/DNA/SWNTs-film-modified Au electrode was successfully prepared, and its electrochemical behavior is investigated by cyclic voltammetry (CV). The modified electrode exhibited a pair of stable and well-defined redox peaks, with the formal potentials (E 0′ at about −0.032 V (vs. SCE) in 0.1 M pH 7.0 phosphate buffer solution (PBS). The dependence of E 0′ on solution pH indicated that the direct electron transfer reaction of the Cysteamine/DNA/SWNTs film is the same electron transfer coupled with the proton participating in the reaction process. Taxol is an anticancer drug; it interacts with microtubule proteins in a manner that catalyzes the formation of microtubules from tubulin and stabilizes the resulting structures. Using the Cysteamine/DNA/SWNTs-film-modified Au electrode, we study the interaction between DNA and Taxol studied. A UV-Vis experiment is performed to confirm this interaction. Published in Russian in Elektrokhimiya, 2008, Vol. 44, No. 9, pp. 1133–1139. The text was submitted by the authors in English.  相似文献   

4.
A continuous amperometric glucose monitoring system is presented. All analytically relevant units are integrated on a microchip (microreactor, control electrode, glucose oxidase based sensor electrode, reference electrode, counter electrode). The scavenging electrochemical microreactor pre-oxidises all interfering compounds enabling a reliable glucose determination. The reliability of the microreactor is demonstrated with the most important antioxidants, ascorbic and uric acids. The glucose sensor system operates at volumetric flow rates of common body interfaces (e.g. microdialysis, microperfusion).  相似文献   

5.
A biocompatible needle-type glucose sensor with a 3-electrode configuration was constructed. A platinum-electroplated carbon stick was used as the working electrode, Ag/AgCl as the reference electrode, and a disposable hypodermic needle made of stainless steel as the counter electrode. A Nafion membrane, an immobilized glucose oxidase (GOD) membrane, and a biocompatible membrane with diffusion-limiting effect were coated successively onto the working electrode. The sensor showed a rapid response (< 120 s in batch operation), good reproducibility (RE < 3%), good stability (over 36 h in control serum), a wide dynamic range (5-600 mg/dL glucose), and superior biocompatibility. It was used to determine glucose in serum. The data obtained from the sensor showed good agreement with that from a clinical autoanalyzer (R > 0.95).  相似文献   

6.
Yamamoto K  Shi G  Zhou T  Xu F  Xu J  Kato T  Jin JY  Jin L 《The Analyst》2003,128(3):249-254
In this paper, multi-walled carbon nanotubes (MWCNTs) were successfully immobilized on the surface of a glassy carbon electrode by mixing with horse-radish peroxidase (HRP). The electrochemical behavior of H2O2 was also studied with the MWCNTs-HRP modified electrode as a working electrode. The MWCNTs-HRP modified electrode showed excellent response of reduction current for the determination of H2O2 at the potential of -300 mV (vs. Ag/AgCl). We assembled the MWCNTs-HRP modified electrode in a thin-layer flow cell and the H2O2 solution was continuously introduced into the cell with a syringe pump. We optimized the sensitivity of the H2O2 sensor by adjusting the working potential and the pH of the buffer solution. The peak current increased linearly with the concentration of H2O2 in the range 3.0 x 10(-7) to approximately 2.0 x 10(-4) mol L(-1). The detection limit is 1.0 x 10(-7) mol L(-1) (S/N = 3). The interferences from ascorbic acid, uric acid and other electroactive substances can be greatly excluded since the sensor can be operated at -300 mV. Stability and reproducibility of the MWCNTs-HRP chemically modified electrode were also studied in this paper. Fabricated with glucose and lactate oxidase, the MWCNTs-HRP electrode was also applied to prepare the on-line glucose and lactate biosensors because of the high sensitivity for the determination of H2O2.  相似文献   

7.
Saleh FS  Mao L  Ohsaka T 《The Analyst》2012,137(9):2233-2238
A new type of dehydrogenase-based amperometric glucose biosensor was constructed using glucose dehydrogenase (GDH) which was immobilized on the edge-plane pyrolytic graphite (EPPG) electrode modified with poly(phenosafranin)-functionalized single-walled carbon nanotubes (PPS-SWCNTs). The PPS-SWCNT-modified EPPG electrode was prepared by electropolymerization of phenosafranin on the EPPG electrode which had been previously coated with SWCNTs. The performance of the GDH/PPS-SWCNT/EPPG bioanode was evaluated using cyclic voltammetry and amperometry in the presence of glucose. The GDH/PPS-SWCNT/EPPG electrode possesses promising characteristics as a glucose sensor: a wide linear dynamic range of 50 to 700 μM, low detection limit of 0.3 μM, fast response time (1-2 s), high sensitivity (96.5 μA cm(-2) mM(-1)), and anti-interference and anti-fouling abilities. Moreover, the performance of the GDH/PPS-SWCNT/EPPG bioanode was tested in a glucose/O(2) biofuel cell. The maximum power density delivered by the assembled glucose/O(2) biofuel cell could reach 64.0 μW cm(-2) at a cell voltage of 0.3 V with 40 mM glucose.  相似文献   

8.
微管作为细胞骨架的主要成分之一,在细胞内执行许多功能.微管是一个动态的结构,既参与细胞运动和细胞内物质运输[‘个又感受、转导外界信号问的刺激产生相应灵敏的反应.尤其它是许多药物,如:紫杉醇(Taxol)、秋水仙素(Colchicine)、等作用的靶子问,因而,微管已成为筛  相似文献   

9.
A novel, stable and sensitive non-enzymatic glucose sensor was developed by potentiostatically electrodepositing metallic Cu nanoparticles on graphene sheets. The electrochemical performance of the Cu-graphene sheets electrode for detection of glucose was investigated by cyclic voltammetry and chronamperometry. The Cu-graphene sheets electrode displayed a synergistic effect of copper nanoparticles and graphene sheets towards the oxidation of glucose in alkaline solution, showing higher oxidation current and negative shift in peak potential. At detection potential of 500 mV, the Cu-graphene electrode sensor presented a wide linear range up to 4.5 mM glucose with a detection limit of 0.5 μM (signal/noise = 3). In addition, the sensor responds very quickly (<2 s) with addition of glucose. Furthermore, the Cu-graphene sheets electrode exhibits high stability and selectivity to glucose, and the poisoning by chloride ion as well as interference from the oxidation of common interfering species (ascorbic, dopamine, uric acid and carbohydrate) are effectively avoided. The Cu-graphene sheets electrode allows highly selective and sensitive, stable and fast amperometric sensing of glucose, which is promising for the development of non-enzymatic glucose sensor.  相似文献   

10.
A new series of 2-phenyl-4,5,6,7-tetrahydro-1H-?indole derivatives as tubulin polymerization inhibitors were synthesized and evaluated for the anti-proliferative activities. All newly prepared compounds were tested for their antiproliferative activity in vitro on the human breast cancer cell line (MCF-7) and human lung adenocarcinoma cell line (A549). Among them, compound 7b with a 4-methoxyl substituent at the phenylhydrazone moiety exhibited the most potent anticancer activity against MCF-7 and A549 with IC50 values of 1.77 ± 0.37 and 3.75 ± 0.11 μM, respectively. Interestingly, 7b displayed significant selectivity in inhibiting cancer cells over LO2 (normal human liver cells). Further mechanism studies revealed that 7b significantly arrested cell cycle at G2/M phase and induced apoptosis in a dose-dependent manner. Additionally, 7b effectively inhibited tubulin polymerization with an inhibitory manner similar to that of colchicine. Furthermore, molecular docking study suggested that 7b had high binding affinities for the colchicine binding pocket of tubulin. Hence, this study demonstrates for the first time that tetrahydroindole can be used as a functional group for the design and development of new tubulin polymerization inhibitors.  相似文献   

11.
用电化学循环伏安法和计时电位法研究了葡萄糖在碳纳米管/纳米TiO2膜载Pt(CNT/nano-TiO2/Pt)复合电极上的电催化氧化,结果表明,在碱性介质中CNT/nano-TiO2/Pt复合电极对葡萄糖的电氧化具有高催化活性,葡萄糖氧化峰电流密度高达13mA/cm^2,比铂电极上的增大一倍;复合电极性能稳定,抗中毒能力强,不易发生氧化振荡,是葡萄糖燃料电池和葡萄糖传感器的高活性催化电极。  相似文献   

12.
Amperometric enzyme electrode for glucose is described based on the incorporation of glucose oxidase (GOD) into graphite paste modified with tetracyanoquinodimethane (TCNQ). The incorporated enzyme exhibits high activity and long-term stability over the earlier TCNQ-based glucose sensor (1). The sensor provides a linear response to glucose over a wide concentration range. The response time of the sensor is 15-50 sec, and the detection limit is 0.5 mM. Stable response to the substrate was obtained during a period of 35 d. Application of the sensor in the plasma analysis is reported.  相似文献   

13.
A porous reticulated vitreous carbon (RVC) electrode and a disk electrode coupled in tandem in an electrochemical flow cell has been used for electrolytic removal of interferents before amperometric glucose detection. The electrolytic efficiency at the upstream RVC electrode is 100% at a flow rate of 0.1 mL min−1 or lower. Potential interferents such as acetaminophen, ascorbic acid, and uric acid can be completely eliminated by electrolysis at the RVC electrode. A mixed monolayer comprising glucose oxidase (GOD) and ferrocenyl-1-undecanethiol preformed at the downstream gold disk electrode was used as a mediator-based amperometric glucose sensor. The dependence of the amperometric current on the glucose concentration exhibits good linearity across over three orders of magnitude. The glucose measurements were also found to be reproducible (RSD < 3.5%) and accurate. Unlike the chemiluminescence method, this device obviates the use of carcinogenic substrates and the glucose sensor performance is independent of the oxygen present in sample. On the basis that the RVC electrode requires minimal cleanup and the GOD-modified electrode remains stable for a week, the electrochemical flow cell should be amenable for automated on-line removal of redox interferents for other types of enzyme-based biosensors.  相似文献   

14.
《Electroanalysis》2017,29(8):1876-1886
A facile chemical solution deposition via two‐step spin coating technique was used to fabricate nano‐particulate novel Sn doped Co3O4 thin film for glucose sensor and fuel cell applications. Substitution of Sn into Co3O4 host lattice lead to a remarkable increase in the electrocatalytic activity of the Co3O4 electrode material. Film thickness played a significant role in enhancing the charge transferability of the electrode as was observed from electrochemical impedance spectroscopy (EIS). The best sensor exhibited two wide linear response ranges (2 μM up to ∼0.5 mM and 0.6 mM up to ∼5.5 mM respectively) with sensitivities of 921 and 265 μA cm−2 mM−1 respectively and low limit of detection of 100 nM (S/N=3). The sensor was very selective towards glucose in the presence of various interference and showed long term stability. Moreover, the developed thin film modified electrode could generate one electron current in nonenzymatic fuel cell setup at room temperature.  相似文献   

15.
In this study, a novel series of isoxazole-naphthalene derivatives as tubulin polymerization inhibitors were designed, synthesized and evaluated for their anti-proliferative activities against human breast cancer cell line MCF-7. Most of the synthesized compounds exhibited moderate to potent antiproliferative activity (IC50 < 10.0 μM), as compared to cisplatin (15.24 ± 1.27 μM). Among them, compound 5j containing 4-ethoxy substitution at phenyl ring was found to be the most active compound with IC50 value of 1.23 ± 0.16 μM. Mechanistic studies revealed that compound 5j arrested cell cycle at G2/M phase and induces apoptosis. Furthermore, in vitro tubulin polymerization assay showed that compound 5j displayed better inhibition activity on tubulin polymerization (IC50 = 3.4 μM) than colchicine (IC50 = 7.5 μM). Molecular docking study also revealed that compound 5j binds to the colchicine binding site of tubulin.  相似文献   

16.
A novel nonenzymatic glucose sensor was successfully fabricated based on the Cu2O polyhedrons covered Cu foil.The Cu2O polyhedrons covered Cu foil was constructed via a facile,low-cost and larger scale producible method.The Cu2O polyhedrons covered Cu foil can be directly used as the working electrode of nonenzymatic glucose sensor,which present good stability and flexibility.The results indicated that the Cu2O polyhedrons modified Cu electrode(Cu2O/Cu electrode) showed high electrocatalytic activity for the oxidation of glucose in alkaline solution.There are two linear regions of glucose concentration for the glucose sensor based on Cu2O/Cu electrode,respectively in 10 mmol/L to 0.53 mmol/L(sensitivity:3029.33 mA(mmol/L) à1 cm à2) and in 0.53-7.53 mmol/L(sensitivity:728.67 mA(mmol/L) à1 cm à2).  相似文献   

17.
A mixed‐valence cluster of cobalt(II) hexacyanoferrate and fullerene C60‐enzyme‐based electrochemical glucose sensor was developed. A water insoluble fullerene C60‐glucose oxidase (C60‐GOD) was prepared and applied as an immobilized enzyme on a glassy carbon electrode with cobalt(II) hexacyanoferrate for analysis of glucose. The glucose in 0.1 M KCl/phosphate buffer solution at pH = 6 was measured with an applied electrode potential at 0.0 mV (vs Ag/AgCl reference electrode). The C60‐GOD‐based electrochemical glucose sensor exhibited efficient electro‐catalytic activity toward the liberated hydrogen peroxide and allowed cathodic detection of glucose. The C60‐GOD electrochemical glucose sensor also showed quite good selectivity to glucose with no interference from easily oxidizable biospecies, e.g. uric acid, ascorbic acid, cysteine, tyrosine, acetaminophen and galactose. The current of H2O2 reduced by cobalt(II) hexacyanoferrate was found to be proportional to the concentration of glucose in aqueous solutions. The immobilized C60‐GOD enzyme‐based glucose sensor exhibited a good linear response up to 8 mM glucose with a sensitivity of 5.60 × 102 nA/mM and a quite short response time of 5 sec. The C60‐GOD‐based glucose sensor also showed a good sensitivity with a detection limit of 1.6 × 10‐6 M and a high reproducibility with a relative standard deviation (RSD) of 4.26%. Effects of pH and temperature on the responses of the immobilized C60‐GOD/cobalt(II) hexacyanoferrate‐based electrochemical glucose sensor were also studied and discussed.  相似文献   

18.
How Taxol stabilises microtubule structure   总被引:8,自引:0,他引:8  
The structure of tubulin shows paclitaxel (Taxol(R)) binding to a pocket in beta tubulin on the microtubule's inner surface, which counteracts the effects of GTP hydrolysis occurring on the other side of the monomer.  相似文献   

19.
A nonenzymatic electrochemical sensor for glucose and fructose was fabricated that contained a glassy carbon electrode modified with a copper oxide (CuO)/multiwalled carbon nanotube (MWCNT) nanocomposite. The electrochemical properties of the CuO/MWCNT‐modified glassy carbon electrode were investigated. Two distinguishable anodic peaks were observed around 0.30 and 0.44 V corresponding to the oxidation of glucose and fructose, respectively, at the surface of the modified electrode. The detection limits for glucose and fructose were both 0.04 mmol/L. The sensor was used to simultaneously determine the concentrations of glucose and fructose in hydrolyzed sucrose samples, and to measure glucose in blood serum samples, demonstrating its potential as a nonenzymatic carbohydrate sensor.  相似文献   

20.
Based on glucose oxidase-immobilized silk fibroin membrane and oxygen electrode, the authors have developed an amperometric glucose sensor in flow-injection analysis. After the sensor was improved by the configuration of oxygen electrode and a temperature control system was added to the electrode body, its sensitivity, analytical precision, and stability were enhanced greatly. The authors first introduced a tailing inhibitor-ion pair reagent into a buffer system in the biosensor so as to eliminate all interference from hemacyte, macromolecules, and small mol wt charged species besides electroactive specie ascorbate in complex matrices. A considerably serious tailing of the biosamples, such as whole blood, plasma, serum, or urine on the sensor, based on enzyme electrode, entirely disappeared, their response times were shortened, and base lines became more smooth and stable. The glucose sensor has a broad range of linear response for glucose (up to 25.0 mmol/L) and a good correlation (γ = 0.999) under conditions of control temperature 32.0°C and 1.6 mL/min 0.02 mol/L phosphate buffer containing 0.5% tailing inhibitor (v/v). Recoveries of glucose in these biosamples are within the range of 93.71–105.88%, and its repeatabilities for determining glucose, repeated 100 times, human blood dilution 125 times, and serum 128 times, are 1.81,2.48, and 2.91% (RSD), respectively. The correlation analysis for 200 serum samples showed that the correlation (γ) is 0.9934 between the glucose sensor and Worthington method for determining serum glucose used conventionally in a hospital laboratory. Moreover, the enzyme membrane used in the biosensor can be stored for a long time (over 2 yr) and measured repeatedly over 1000 times for biosamples. The glucose sensor is capable of detecting over 60 biosamples/hr.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号