首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
建立了一种反相高效液相色谱-二极管阵列检测器同时测定祛痘类化妆品中美满霉素、土霉素、四环素、金霉素、多西环素、氯霉素及甲硝唑的分析方法。样品用0.1 mol/L HCl-甲醇提取,采用Agilent SB-C18色谱柱分离,以甲醇、乙腈和0.005 mol/L草酸为流动相进行梯度洗脱,二极管阵列检测器检测,检测波长268 nm,以保留时间和特征光谱图定性,外标法定量。结果表明,7种化合物在0.5~100 mg/L均与其各自对应的峰面积呈良好线性关系(r≥0.9992),方法定量限(S/N=10)为1.0~10.0 mg/kg,回收率在80.5%~112.8%之间,精密度在6.4%~13%之间。该方法适用于祛痘化妆品中6种抗生素及甲硝唑的检测。  相似文献   

2.
高效液相色谱法同时检测祛痘类化妆品中12种禁限用物质   总被引:1,自引:0,他引:1  
建立了反相高效液相色谱同时测定祛痘类化妆品中12种禁限用物质(依诺沙星、环丙沙星、氧氟沙星、林可霉素、克林霉素、克林霉素磷酸酯、氯霉素、氯霉素二醇物、磺胺甲口恶唑、甲硝唑、替硝唑、水杨酸)的方法。样品经甲醇与0.1 mol/L盐酸混合溶液(体积比1∶1)超声提取,采用ACEC18(250 mm×4.6 mm,5μm)色谱柱分离,以乙腈-0.025 mol/L磷酸三乙胺溶液二元流动相梯度洗脱,流速1.5 mL/min,柱温40℃,采用二极管阵列检测器双波长(210、277 nm)检测,外标法定量。林可霉素、克林霉素、克林霉素磷酸酯3种成分的线性范围为25~1 000mg/L,其他9种成分的线性范围为5~200 mg/L,相关系数均大于0.997。12种禁限用物质的方法检出限为5~50μg/g,平均回收率为88%~115%,相对标准偏差为0.4%~3.0%。该方法操作简便、准确、灵敏,适用于祛痘类化妆品中12种禁限用物质的测定。  相似文献   

3.
严丽娟  张峰  方恩华  郭彦妮  周昱  林立毅  储晓刚 《色谱》2010,28(11):1038-1042
建立了动物饲料中竹桃霉素、红霉素、吉他霉素、交沙霉素、罗红霉素、泰乐菌素6种大环内酯和林可霉素、克林霉素2种林可胺抗生素的超高效液相色谱-电喷雾串联质谱(UPLC-ESI-MS/MS)检测方法。饲料样品采用甲醇提取,Oasis HLB固相萃取柱富集净化,Waters Acquity UPLC BEH C18色谱柱分离,以0.1%甲酸和乙腈为流动相进行梯度洗脱,流速为0.3 mL/min,正离子模式扫描,多反应监测模式检测,外标法定量。实验结果表明,8种药物在1~100 μg/L范围内具有良好的线性关系。在空白饲料样品中分别添加1、10和100 μg/kg 3个加标水平的8种药物,其平均回收率为68.6%~95.2%,相对标准偏差(RSD)为4.9%~11.8%,定量限均为1 μg/kg。结果表明,该方法简便快速、灵敏度高,适用于动物饲料中大环内酯类和林可胺类抗生素的同时检测。  相似文献   

4.
Wu G  Zhao S  Wu J  Dong S  Guo F  Wang L  Ye Q 《色谱》2011,29(6):501-506
利用超高效液相色谱-串联质谱(UPLC-MS/MS)结合凝胶渗透色谱(GPC)技术,建立了一种快速分离和测定皮革制品中7种尼泊金酯类防腐剂的分析方法。样品经超声提取、浓缩、GPC净化,甲醇-水溶液(1:1, v/v)溶解,采用Acquity UPLCBEH C18柱(50 mm×2.1 mm, 1.7 μm)分离,以甲醇和水为流动相,梯度洗脱,电喷雾负离子模式电离,采用多反应监测模式检测和外标法定量。该方法在0.1~1.0 mg/L范围内线性关系良好(r>0.99);在添加量为0.5~3.0 mg/kg时,平均回收率为(79.44±5.67)%~(98.07±9.50)%,相对标准偏差(RSD)为4.24%~14.00%;方法的检出限(LOD)为4~12 μg/kg,定量限(LOQ)为13.2~39.6 μg/kg。该方法操作简便、快捷、灵敏、准确,适合皮革中多种尼泊金酯类防腐剂的确证和定量测定。  相似文献   

5.
禤学怡  黄丽娜  潘晓玲  李宁 《色谱》2013,31(2):133-138
建立了一种pH/溶剂双梯度反相高效液相色谱(HPLC)同时测定氨酚曲麻片中对乙酰氨基酚、咖啡因、水杨酰胺、盐酸伪麻黄碱、盐酸曲普利啶5种有效成分的方法。通过对溶剂梯度和pH/溶剂双梯度体系的优化,得到分离5种成分的最佳色谱体系。采用Diamonsiol C18色谱柱(250 mm×4.6 mm, 5 μm),以甲醇、0.05 mol/L醋酸铵水溶液和0.08 mol/L醋酸水溶液组成三元流动相体系,pH/溶剂双梯度洗脱,流速为1.0 mL/min;柱温为30 ℃。采用分段变波长检测: 0~6 min, 280 nm; 6~7 min, 257 nm; 7~14 min, 280 nm; 14 min, 233 nm。片剂中的5种成分在25.5 min内能达到基线分离,对乙酰氨基酚、盐酸伪麻黄碱、咖啡因、水杨酰胺、盐酸曲普利啶5种成分的线性范围分别为0.055~0.998 g/L、0.053~0.946 g/L、0.007~0.129 g/L、0.035~0.622 g/L和0.002~0.039 g/L,相关系数r均大于0.9990;检出限(以信噪比为3(S/N=3)计)分别为0.09、6、0.02、0.128和0.02 mg/L,回收率为97.9%~102.8%。该方法能在短时间内同时分离酸性、中性和碱性化合物,能提高被测物的柱效,减少半峰宽和拖尾,可应用于氨酚曲麻片中5种成分的含量分析。  相似文献   

6.
阴离子交换色谱-脉冲安培法检测味精中的硫化物   总被引:1,自引:0,他引:1  
李仁勇  梁立娜  李静 《色谱》2010,28(12):1158-1161
建立了阴离子交换色谱柱分离、脉冲安培检测器测定味精中微量硫化物的方法。味精样品经2 g/L氢氧化钠溶液直接溶解并过滤后直接进样,硫离子与高浓度谷氨酸等阴离子在IonPac AS7阴离子色谱柱(250 mm×4 mm)上可实现较好的分离。以100 mmol/L氢氧化钠-500 mmol/L醋酸钠-0.5%乙二胺为淋洗液等度淋洗,6 min内可完成一次样品测定。脉冲安培检测器检测硫离子的检出限(25 μL进样,信噪比为3)为0.3 μg/L,并具有较宽的线性范围(0.001~1 mg/L),样品加标回收率为94.2%~99.0%。应用该方法检测99%味精、增鲜味精和加盐味精样品中的硫化物,结果表明该方法具有简便快捷、高选择性、高灵敏度等优点。  相似文献   

7.
周卫军  谢正福  邵琳智 《色谱》2012,30(7):684-689
采用高效液相色谱-串联质谱技术,建立了口腔卫生产品(牙膏及漱口水)中5类共13种抗生素的同时检测方法。分析物包括5种四环素类、3种大环内酯类、2种喹诺酮类、1种β-内酰胺类和2种林可胺类抗生素。样品经0.1%(体积分数,下同)甲酸溶液-乙腈(95:5, v/v)提取,高速离心并过滤,稀释后采用C18色谱柱(150 mm×2.1 mm, 5 μm)分离,以0.1%甲酸溶液-乙腈为流动相梯度洗脱,采用电喷雾离子源串联质谱,在正离子扫描方式下以多反应监测(MRM)模式检测,外标法定量。13种抗生素类药物在5.0~50.0 μg/L质量浓度范围内线性关系良好(相关系数大于0.99),定量限为10.0 mg/kg。两种基质(牙膏及漱口水)样品在10、20和100 mg/kg 3个加标水平下的平均回收率为80.1%~115%,相对标准偏差为0.94%~8.69%。该方法准确可靠、方便快捷,适用于口腔卫生产品中抗生素类药物的定性定量分析。  相似文献   

8.
高效液相色谱法测定化妆品中的12种紫外吸收剂   总被引:1,自引:0,他引:1  
He Q  Xu N  Li J  Liao S 《色谱》2011,29(8):762-767
建立了高效液相色谱同时测定化妆品中12种紫外吸收剂含量的方法。样品用甲醇提取,高速离心,过滤,以SB-C8柱(250 mm×4.6 mm, 5 μm)为分离色谱柱,甲醇和0.1%(v/v)甲酸水溶液为流动相,梯度洗脱,以311 nm为检测波长进行定性、定量分析。该方法前处理简单、易操作,12种紫外吸收剂分离效果良好;在1.0~500 mg/L范围内呈线性关系,相关系数大于0.9995;方法检出限为0.002~0.1 mg/L;实际样品中的加标回收率为97.4%~107.5%,相对标准偏差为1.54%~4.98%。该方法简便、准确,能够满足化妆品中紫外吸收剂的检测要求。  相似文献   

9.
刘晓霞  丁利  刘锦霞  张莹  黄志强  王利兵  陈波 《色谱》2010,28(11):1020-1025
建立了食品中6种人工合成甜味剂(甜蜜素、糖精钠、安赛蜜、阿斯巴甜、阿力甜、纽甜)的高效液相色谱-串联质谱检测方法。样品经甲醇-水溶液(1:1, v/v)提取,以C18柱为分离柱,0.1%(v/v)甲酸-5 mmol/L甲酸铵溶液/乙腈为流动相,经高效液相色谱分离,采用电喷雾串联四极杆质谱进行检测。结果表明,6种人工合成甜味剂在20~500 μg/L范围内定量离子对的响应峰面积和样品质量浓度之间有良好的线性关系(相关系数>0.998)。在3个添加水平下,样品平均回收率为81.3%~106.0%,相对标准偏差小于11%。该方法简单、灵敏、准确,可用于食品中6种人工合成甜味剂的同时检测。  相似文献   

10.
Zhang J  Li J  Shao D  Yao B  Jiang J 《色谱》2012,30(2):190-195
建立了同时测定食品塑料包装材料中9种紫外光稳定剂含量的高效液相色谱方法。样品用甲醇-乙酸乙酯混合溶剂超声提取,经固相萃取小柱净化后,以ZORBAX SB-C18柱(250 mm×4.6 mm, 5 μm)为分离色谱柱,甲醇和水为流动相,梯度洗脱,以310 nm为检测波长进行定性、定量分析。该方法前处理简单、易操作,9种紫外光稳定剂分离效果良好。9种紫外光稳定剂在0.2~10 mg/L范围内呈良好的线性关系,线性相关系数大于0.999;方法检出限为0.05~0.1 mg/L;实际样品中的加标回收率为70.2%~89.0%,相对标准偏差为0.4%~4.5%。该方法简单、准确,能够满足食品塑料包装材料中紫外光稳定剂的检测要求。  相似文献   

11.
建立了以活性碳纤维作吸附剂,流动注射在线预富集与高效液相色谱联用法测定水产品中4种磺胺类药物(磺胺噻唑、磺胺二甲嘧啶、磺胺间甲氧嘧啶、磺胺喹啉)残留含量的方法。样品经磷酸盐缓冲溶液提取后,采用活性碳纤维作吸附剂流动注射在线预富集,在pH 3.0的甲酸溶液-甲酸甲醇溶液(60∶40,V/V)的流动相体系中,用Eclipse XDB-C18色谱柱(250 mm×4.6 mm,5μm)分离,流速1.0 mL/min;检测波长270nm。结果表明,4种磺胺类药物在0.001~0.064 mg/L浓度范围内呈良好的线性关系,相关系数r为0.9997~0.9999;检出限为0.48~1.15μg/L(S/N=3);富集倍数在137~406之间;加标回收率为93.5%~104.0%。本方法操作简便、结果准确、灵敏度高。  相似文献   

12.
We report the development and validation of a stability‐indicating reversed‐phase high‐performance liquid chromatography method with precolumn derivatization for the separation and identification of the impurities of ripasudil hydrochloride hydrate, a novel protein kinase inhibitor. 2,3,4,6‐Tetra‐O‐acetyl‐β‐d ‐glucopyranosyl isothiocyanate was chosen as the derivatizing reagent and triethylamine was added as catalyst. 200 μL sample solution (1 mg/mL), 600 μL derivatizing reagent (1 mg/mL), and 200 μL triethylamine solution (1%, v/v) were mixed and reacted at 40°C for 30 min. The separation was achieved on an Inertsil C18 ODS‐3 (250 mm × 4.6 mm, 5 μm) column using mobile phases including 10 mmol monopotassium phosphate buffer (pH 3.0) and methanol in gradient mode. The column temperature was adjusted at 25°C and the flow rate at 1 mL/min. The detection was carried out at 220 nm. Different precolumn derivatization conditions as well as the high‐performance liquid chromatography conditions were optimized. Ripasudil hydrochloride hydrate and its four impurities were detected and quantitated, among which two new compounds were characterized. The proposed method was validated and proven to be selective, accurate, and precise and suitable for the quantitative analysis of ripasudil hydrochloride hydrate.  相似文献   

13.
采用手性多羟基化合物—硼酸络合酸为手性选择剂,建立了分离盐酸莱克多巴胺4个立体异构体的手性毛细管电泳(NACE)方法.实验考察了手性选择剂的种类、浓度和三乙胺浓度对手性分离效果的影响.结果表明,双丙酮-D-甘露糖醇—硼酸络合酸手性选择剂的分离效果最好,优化的缓冲溶液组成为含100 mmol/L双丙酮-D-甘露糖醇、10...  相似文献   

14.
采用超声萃取、固相萃取及高效液相色谱-质谱联用技术(LC-MS),建立了活性污泥中3类共9种抗生素(包括5种磺胺类、3种四环素类及1种大环内酯类)的同时分析方法.样品经甲醇-Na2,EDTA/Mcllvaine缓冲液(1∶1,体积比)超声萃取,HLB固相萃取柱净化富集后,以Symmetry C18反相柱为分析柱,0.2...  相似文献   

15.
建立超高效液相色谱法快速检测虾青素的方法。采用UPLC BEH C_8色谱柱(50 mm×2.1 mm,1.7μm),考察了流动相、流量及柱温对虾青素样品分离的影响,确定了最佳色谱条件:等度洗脱,流动相为甲醇–水(体积比为75∶25),流量为0.5 mL/min,柱温为40℃,检测波长为475 nm。虾青素的质量浓度在0.2~10.0μg/mL范围内与其色谱峰面积呈良好的线性关系,线性相关系数r=0.998 8,检出限(S/N=3)为0.1μg/mL,定量限(S/N=10)为0.2μg/mL。测定结果的相对标准偏差为0.41%(n=6),加标回收率为105.8%~110.3%。该方法快速、简单、可靠、灵敏、重复性好,可用于虾青素有关样品的快速检测。  相似文献   

16.
采用微芯片毛细管电泳非接触电导检测法快速测定了盐酸洛美沙星胶囊中盐酸洛美沙星的含量。探讨了缓冲液类型、浓度,添加剂种类、浓度及分离电压、进样时间等因素对分离检测的影响。实验采用5.0mmol/L HAc(pH=2.5)+5%乙醇为缓冲溶液,分离电压3.0 kV,在1 min内实现了盐酸洛美沙星的快速分离测定。优化条件下盐酸洛美沙星的线性范围为20.0~250.0μg/mL,检出限为10.0μg/mL(S/N=3),RSD=2.0%,加标回收率为98.6%~103%。  相似文献   

17.
郑玲  吴玉杰  李湧  李丽华 《色谱》2012,30(7):660-664
建立了动物源食品中喹喔啉类药物代谢残留标识物3-甲基喹喔啉-2-羧酸和喹喔啉-2-羧酸的高效液相色谱-串联质谱检测方法。样品在酸性环境水解,经乙酸乙酯、磷酸盐缓冲液依次提取,Oasis MAX固相萃取小柱净化,用Waters Xterra MS C18柱(150 mm×2.1 mm, 5 μm)分离,以甲醇-0.2%甲酸为流动相梯度洗脱,采用多反应监测(MRM)正离子模式检测,内标法定量。各物质在1.0~20.0 μg/L范围内线性关系良好,相关系数均不低于0.9996; 3-甲基喹喔啉-2-羧酸和喹喔啉-2-羧酸在0.1、0.2、1.0 μg/kg加标水平的回收率为62.4%~118%,相对标准偏差为1.48%~28.1%;定量限(以信噪比≥10计)为0.1 μg/kg。该方法简单、灵敏、稳定,可满足猪肉、猪肝、鸡肉、鸡肝、鱼、虾等动物源食品中3-甲基喹喔啉-2-羧酸和喹喔啉-2-羧酸残留的检测与确证需要。  相似文献   

18.
高效液相色谱法同时测定肉制品中的6种食品添加剂   总被引:1,自引:0,他引:1  
李秀琴  张庆合  杨总 《色谱》2010,28(12):1204-1208
建立了同时测定肉制品中化学性质差异较大的6种常用食品添加剂的高效液相色谱(HPLC)分析方法。根据6种添加剂(苯甲酸(钠)、山梨酸(钾)、糖精钠、安赛蜜、诱惑红和胭脂红)的化学性质,对HPLC分析条件进行了详细的优化。结果表明:以ZORBAX Eclipse Plus C18柱(150mm×4.6mm,5μm)为分析柱,以甲醇和20mmol/L醋酸铵溶液(pH为6.9)为流动相进行梯度洗脱,在235nm波长下进行检测,可以在18min内完成6种添加剂的同时测定。在高、低两个加标浓度下,样品的回收率为80.7%~94.4%,相对标准偏差(n=3)为2.0%~7.1%。结果表明,该方法快速、准确,能够同时分析测定肉制品中上述6种食品添加剂。  相似文献   

19.
ABSTRACT: A simple reversed phase high performance liquid chromatographic method with diode array detector (HPLC-DAD) has been developed and subsequently validated for the determination of fexofenadine hydrochloride (FEX) and its related compounds; keto fexofenadine (Impurity A), meta isomer of fexofenadine (Impurity B), methyl ester of fexofenadine (Impurity C) in addition to the methyl ester of ketofexofenadine (Impurity D). The separation was based on the use of a Hypersil BDS C-18 analytical column (250 × 4.6 mm, i.d., 5 μm). The mobile phase consisted of a mixture of phosphate buffer containing 0.1 gm% of 1-octane sulphonic acid sodium salt monohydrate and 1% (v/v) of triethylamine, pH 2.7 and methanol (60:40, v/v). The separation was carried out at ambient temperature with a flow rate of 1.5 ml/min. Quantitation was achieved with UV detection at 215 nm using lisinopril as internal standard, with linear calibration curves at concentration ranges 0.1-50 μg/ml for FEX and its related compounds. The optimized conditions were used to develop a stability-indicating HPLC-DAD method for the quantitative determination of FEX and its related compounds in tablet dosage forms. The drugs were subjected to oxidation, hydrolysis, photolysis and heat to apply stress conditions. Complete separation was achieved for the parent compounds and all degradation products. The method was validated according to ICH guidelines in terms of accuracy, precision, robustness, limits of detection and quantitation and other aspects of analytical validation.  相似文献   

20.
通过对提取溶剂、净化方法及色谱-质谱条件的优化,建立了配合饲料中阿奇霉素(AZM)的液相色谱-串联质谱测定方法。样品经乙腈超声波提取,MCX固相萃取柱净化,BDS Hypersil C_(18)(2.4μm,100 mm×2.1 mm)色谱柱分离,以甲醇-0.05 mol/L乙酸铵水溶液为流动相梯度洗脱,正离子模式电离,多反应监测模式检测,同位素内标法定量。在优化条件下,AZM在1~250μg/L范围内线性关系良好,相关系数(r~2)为0.999 1,检出限(S/N≥3)为2.8μg/kg,定量下限(S/N≥10)为8.4μg/kg;在0.5,1,5,10 mg/kg加标水平下,回收率为87.0%~106.6%,批内相对标准偏差为0.58%~5.4%,批间相对标准偏差为3.1%~5.4%。该方法准确、灵敏,选择性强,基质干扰小,可用于配合饲料中AZM的测定。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号